MANIFOLDS - Instrumart€¦ · Transmitter connection is 1/2“-14 NPT male and process connection...
Transcript of MANIFOLDS - Instrumart€¦ · Transmitter connection is 1/2“-14 NPT male and process connection...
MANIFOLDS
EDS5-F03f
DATASHEET
Date September 2016
The FUJI FCX-AII differential, gauge and absolute pressure transmitters can be direct mounted with different kinds of manifold, adapted for the application and the type of transmitter.The manifolds can be delivered mounted on the transmitters or supplied separately.When supplied mounted, the complete assembly is fully pressure tested, and calibrated in the factory.
Technical information
Material : Standard : Stainless steel 316 for manifold body and valves. Carbon steel : for quantities of 30 or more (consultFuji). Upon request : body material in Monel, Duplex,Hastelloy, etc... Bolts material : stainless steel 316. Gasket : PTFE (standard), Grafoil, Kevlar etc...
Bolting size : M10 for static pressure 160 bar max. and gauge pres-sure for 100 bar max.M12 and 7/16 - 20 UNF for 420 bar static and 500 bar gauge pressure.
Mounting : Manifold can be mounted on the transmitter. All tests and manufacturing operations will be done with the-manifold : - Pressure test (leakage test) at 1,5 x static pressure for differ-
ential pressure transmitter at overpressure rating for gauge and absolute pressure transmitters.
- Calibration with factory facilities.
Process connection :1/2”-14 NPT, others upon request.
Operating pressure : The maximum pressure is 414 bar (6000 PSI).Upon request, manifolds for maximum pressure 690 bar (10000 PSI) can be delivered.
M
Code symbols
1 2 3 4 5
Manifolds
23
5
6
7
89
E
Type1 Valve - type HGVS8F8MPBV-FU - SS3162 Valves - type HDS2HLH-FU - SS 3163 Valves - type HDS3DTPPD-FU - SS 3163 Valves - type HDS3M-FU - SS 3165 Valves - type HDS5M-FU - SS 3163 Valves - type flange/flange HFS3-FU - SS 3162 Valves - type HALS2V-RHV - SS 316
M E
Bolting size / matirial7/16 - 20 UNF - Carbon steel7/16 - 20 UNF - SS 316M10 - SS 316M12 - SS 316None
0
1
2
3
4ConstructionStainless steel
2
1
Mounted on transmitterYesNo - Separate kit
*3
*1
*4
*5
*2
Notes :1 : For 420 bar static pressure (differential pressure), and 500 bar
(gauge pressure), M10 bolting is not suitable, please select 7/16 or M12.
2 : No bolting is necessary for this manifold type. 3 : When manifold is ordered mounted on the transmitter, hydros-
tatic pressure test and calibration are made with manifold, so complete set is tested.
4 : Manifold type HDS3M-FU is low cost version of type HDS3DTP-PD-FU. The design of the process connection is smaller.
5 : Supplied with fitting if connection 1/2" NPT Female
Fuji Electric France S.A.S.
2
M
Type HGVS8F8MPBV-FU - 1 valve manifold
Multiport one valve manifold, with separate vent or calibration facilities. Transmitter connection is 1/2“-14 NPT male and process connection (customer side) is 1/2“ NPT female.It can be direct mounted on FKP transmitter or via oval flange (1/2“-14 NPT) on FCX-AII transmitters. Maximum presure : 414 bar (6000 PSI).
Type HDS2HLH-FU - 2 valves manifold
Direct mounted 2 valve manifold delivered with 2 bolts and one PTFE gasket. Both valves have the inlet and drain/vent connection on the mounting face and are suitable for all applications up to 414 bar (6000 PSI).This manifold can be mounted on FCX-AII gauge and absolute pressure transmitter. Process connection is 1/2“-14 NPT female
Type HALS2V-RHV - 2 valves manifold
Direct mounted 2 valve manifold delivered with 2 bolts and one PTFE gasket. Both valves have the inlet and drain/vent connection on the mounting face and are suitable for all applications up to 414 bar (6000 PSI).This manifold can be mounted on FCX-AII gauge and absolute pressure transmitter. Process connection is 1/2“-14 NPT female
OUTLINE DIMENSIONS (unit : mm)
92.0
28.6
28.6
79.4 (OPEN )76.4 (CLOSED)
55.0
1/2-14 NPT (FEM)
1/2-14 NPT(FEM)
ISOLATE VALVE
1/2-14 NPT (MALE)
70.1
63.5
113.0
63.5
114.3 (Open)111.3 (Closed)
28.6
M10 x 1.5p
2 - Ø12.0 MTG. HOLES
M6 x 1.01/4-18 NPT(VENT)
1/2-14 NPT(INLET)
41.3
24.0
8.3
11.2
79.4 [3.125] (OPEN REF.)76.4 [3.008] (CLOSED REF.)
100.2[3.945]
(MAX REF.)
50.8[2.000]
28.6[1.125]1/2-14 NPT
(FEM) INLET1/2-14 NPT (FEM) OUTLET
1/4-18 NPT (FEM) VENT
30.0[1.181]
10.4[0.409]
63.5[2.500]
2-OFF 5.5 [0.217]MTG. HOLES
3
Type HDS3DTPPD- FU - 3 valves manifold
Alternative solution for 3 valve manifold with some additional facilities like more space for the customer process connec-tion and 2 additional pluged vent ports (1/4“-18 NPT). The 3 valves are mounted in line on the top of the manifold body. Process connections are 1/2“-14 NPT female at 102 mm centers; Maximum pressure 414 bar (6000 PSI).Supplied with 4 bolts and 2 PTFE gaskets
Type HDS3M-FU - 3 valves manifold
This manifold type can be used on the differential pressure and flow transmitters on FCX-AII series.The 2 isolating valves (HP& LPside) are on the body ends of the manifold and the equalising valve on the top.Process connections are 1/2“-14 NPT female at 54 mm (2“ 1/8) centers. Maximum pressure 414 bar (6000 PSI). Supplied with 4 bolts and 2 PTFE gaskets.
147.0
107.8(Open)
63.5
28.6
10.0
35.0
30.0
54.0
102.0
41.3
138.0
4 - Ø12MTG. HOLES
2 - 1/2-14 NPT(INLETS)
2 - M10 x 1.5MTG. HOLES
2 - 1/4-18 NPTDOWNSTREAM TEST
11.214.3
28.6
110.0
211.6 (Open)205.6 (Closed)
2 - M10 x 1.5MTG. HOLES
4 - Ø12MTG. HOLES
54.0
41.3
113.0(Open)
63.5
2 - 1/2-14 NPT(INLET)
30.0
11.2
M
Fuji Electric can accept no responsibility for possible errors in catalogues, brochures and other printed material. Fuji Electric reserves the right to alter its products without no-tice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. All rights reseved.
Fuji Electric France S.A.S.46 rue Georges Besse - ZI du brézet - 63039 Clermont ferrandTél : 04 73 98 26 98 - Fax : 04 73 98 26 99Mail : [email protected] - web : www.fujielectric.fr
Type HDS5M-FU - 5 valves manifold
This manifold type is used on the diffe-rential and flow transmitters on FCX-AII series. It combines 2 isolating valves (HP& LPside) 2 drain / vent valves and one equalising valve. Suitable for applications up to 414 bar (6000 PSI). Process connections : 1/2“-14 NPT female at 54 mm or (2“ - 1/8) centers. Supplied with 4 bolts and 2 PTFE gaskets.
Type HFS3-FU - 5 valves manifold - Flange/Flange
3 valves and flange/flange manifold used on the differential and flow transmitters on FCX-AII series. The 2 isolating valves (HP& LPside) are on the body ends of the manifold and the equalising valve on the top for applications up to 414 bar (6000 PSI).
239.6 (Open)233.6 (Closed)
113.0(Open)
63.5
28.654.0
138.0
41.3
30.0
2 - 1/2-14 NPT(INLETS)
4 -Ø12MTG. HOLES
2 - 1/4-18 NPT(VENTS)
2 - M10 x 1.5MTG. HOLES
102.0
11.2
85.6
54.0
41.3
187.2 (Open)181.2 (Closed)
67.0
61.5
118.0Max
INLET suitablefor kindly flange
4 - Ø12MTG. HOLES