MAN Pump Mode Key (Manual) 9 10 3AUT Pump Mode Key ...

3
SET 1. DESCRIPTION The Microsol SWP Advanced is a differential thermostat for solar heating that controls the water circulation pump based on the temperature differential between the solar collector and the pool or thermal reservoir. The controller has functions to prevent overheating and freezing of water in the solar collector. Also provides access protection to the parameters configuration. The Microsol Advanced series is characterized by distinctive design for use in residential environments, by operation facility With easy access keys to main features of the controller and the use of the custom display. The display technology employed allows providing a simple and complete information of the solar heating system, such as: output status, operation mode of the pump, position and temperature of sensors. 2. APPLICATION - Solar heating systems for swimming pools - Solar heating systems for thermal reservoirs 3. TECHNICAL SPECIFICATIONS -Power: Microsol SWP Advanced: 230Vac ±10%(50/60Hz) or version 115Vac ±10%(50/60Hz) - Operating temperature: 0 to 50ºC - Operating humidity: 10 to 90% UR (without condensation) - Sensors: The Microsol SWP Advanced has 2 sensors: Sensor T1: Solar Collector – SB59 Sensor, white cable, Silicone, 1m Sensor T2: Thermal reservoir – SB19 Sensor, black cable, 2m - Control temperature: Sensor T1: -50 to 200ºC / -58 to 392ºF Sensor T2: -50 to 105ºC / -58 to 221ºF - Resolution: 0.1ºC between -10 and 100ºC and 1ºC in the remaining range 1ºF in all range - Control output: The Microsol SWP Advanced has one relay output: PUMP - Relay output, max. 1HP in 220Vca (½ HP in 127 Vca) - Dimensions: 104 x 148 x 32 mm - Display: LCD 2.75'' with backlight 4. INDICATIONS AND SCREEN 4.1 PRESENTATION 4.2 INDICATIONS In programming, parameter setting released In programming, parameter setting locked Display of temperature on the Fahrenheit scale Display of temperature on the Celsius scale Pump on due the cooling function Pump on due the antifreeze function Pump on due the function of the vacuum tube Pump on due the temperature differential (T1-T2) Output of pump on T1 sensor position - solar collector T2 sensor position - pool / thermal reservoir Indicates the occurrence of overheating T1 Indicates the occurrence of T1 sensor error - solar collector Indicates the occurrence of T2 sensor error - pool / thermal reservoir Lock functions enabled 5. OPERATIONS FOR DOMESTIC USER 5.1 MAP OF KEYS The controller has facilitated accesses to the pertinent resources to the user. Following table describing these: Short press: temperature setting for heating the pool / reservoir Long press (4 seconds): access to advanced settings Long press (see F12 parameter): enable/disable lock of functions Short press: Toggles the display of the temperature (DIF, T1, T2) for 10 seconds Short press: Toggles the pump mode for MANUAL ON (MAN) Short press: Toggles the pump mode for AUTOMATIC (AUT) Short press: Toggles the pump mode for OFF (Disconnected) 5.2 POOL/RESERVOIR HEATING TEMPERATURE (T2 SENSOR) Sets the comfort temperature of the pool or thermal reservoir (T2). Upon reaching this temperature the water circulation pump is disconnected, avoiding thermal discomfort. To adjust this parameter give a short press on the SET key. Use or keys to adjust the value. To confirm this give a short press on the SET key and the value is saved in the controller's memory. This parameter can be adjusted between 0.0 to 105 °C or between 32 to 221°F. 5.3 PUMP WATER OPERATION MODE To change the operation mode of the water pump use , and keys. The circulation water pump between the solar collector and thermal pool or reservoir can operate in three different modes. Description below: Obs.: In the pump mode adjustment, the controller assumes the new Mode 5 seconds after your selection. This is also the time required for the parameter to be stored in its memory. When selected the MAN (manual) mode, the operation mode of the pump remains in this state for a period of 6 hours (fixed time) after the controller assumes the AUT (AUTO) mode. If you want to return to the AUT mode before 6 hours, press the AUT key at any time. 5.4 VIEW OTHER TEMPERATURES To toggle between the display of the T1 temperature sensor, T2 sensor or differential of these (T1-T2), give short press on key until the desired temperature appears on the display. On digits in the upper display the measured temperature is displayed, and on the digits of the lower display the sensor description. The selected temperature is displayed on the display for 10 seconds, after this preferential indication is displayed again, as set in [,F01] parameter - Preferred Indication. 5.5 LOCK OF FUNCTIONS For security purposes and to prevent unauthorized users from changing the settings of the controller, there is a lockout of functions feature. With this setting enabled, the parameters cannot be changed, however, can be viewed. In the lock condition, trying to change the value of a parameter is displayed the [,LOC][,,On] message on the display. To enable / disable the locking function should keep pressed the key the time set in parameter [,F12] - Time to lock functions. The icon indicates the user the lock state, when lit indicates that the lock function is active. CLUE: with the lock functions enabled, you avoid children, visitors or curious will change the operation mode or controller parameters. When there is need for a change, just hold down the key to enable / disable this feature. 1 2 3 4 5 6 7 8 9 10 11 MAN Pump Mode Key (Manual) AUT Pump Mode Key (Automatic) OFF Pump Mode Key (Disconnected) Decrease Key SET Key Increase Key Pump operation mode indication Signs of the controller Solar heating system indication Digits of the lower display Digits of the upper display SET LOC MAX + + + AUT PUMP off PUMP MAN PUMP SET SET 6. ADVANCED OPERATIONS FOR INSTALLER (TECHNICAL USE) 6.1 CHANGE OF CONTROLLER PARAMETERS Access the settings menu by pressing the SET key for 4 seconds until [FuNc] appears. Then [Code] appears, then press the SET key again, short press. Use the or keys to enter the value of the access code 123, and when ready press the SET key (short press) again. Use the or keys to select the desired function. With a short press on the SET key you can edit its value. Use the or keys to change the value, when ready give a short press the SET key to store the set value and return to the function menu. To exit the menu and return to normal operation (temperature indication) press and hold the SET key (long press) until [----]appears. MCSOLADVANSWP01-03T-16453 DIFFERENTIAL THERMOSTAT FOR SOLAR HEATING Ver. 01 A SET 1 2 3 6 5 4 MAX am pm SET LOC AUT off MAN PUMP 7 8 11 9 10 am pm AUT PUMP SWP AUT= Circulation pump in automatic mode operating as setting of the parameters MAN= Circulation pump On OFF= Circulation pump always turned off Attention: In this mode the pump is maintained turned on , ignoring the protection functions and temperature sensors.

Transcript of MAN Pump Mode Key (Manual) 9 10 3AUT Pump Mode Key ...

Page 1: MAN Pump Mode Key (Manual) 9 10 3AUT Pump Mode Key ...

SET

1. DESCRIPTION

The Microsol SWP Advanced is a differential thermostat for solar heating that controls the water circulation pump based on the temperature differential between the solar collector and the pool or thermal reservoir. The controller has functions to prevent overheating and freezing of water in the solar collector. Also provides access protection to the parameters configuration.The Microsol Advanced series is characterized by distinctive design for use in residential environments, by operation facility With easy access keys to main features of the controller and the use of the custom display. The display technology employed allows providing a simple and complete information of the solar heating system, such as: output status, operation mode of the pump, position and temperature of sensors.

2. APPLICATION- Solar heating systems for swimming pools- Solar heating systems for thermal reservoirs

3. TECHNICAL SPECIFICATIONS-Power: Microsol SWP Advanced: 230Vac ±10%(50/60Hz) or version 115Vac ±10%(50/60Hz)- Operating temperature: 0 to 50ºC- Operating humidity: 10 to 90% UR (without condensation)- Sensors: The Microsol SWP Advanced has 2 sensors:

Sensor T1: Solar Collector – SB59 Sensor, white cable, Silicone, 1mSensor T2: Thermal reservoir – SB19 Sensor, black cable, 2m

- Control temperature: Sensor T1: -50 to 200ºC / -58 to 392ºFSensor T2: -50 to 105ºC / -58 to 221ºF

- Resolution: 0.1ºC between -10 and 100ºC and 1ºC in the remaining range1ºF in all range

- Control output: The Microsol SWP Advanced has one relay output: PUMP - Relay output, max. 1HP in 220Vca (½ HP in 127 Vca)- Dimensions: 104 x 148 x 32 mm- Display: LCD 2.75'' with backlight

4. INDICATIONS AND SCREEN4.1 PRESENTATION

4.2 INDICATIONS

In programming, parameter setting released

In programming, parameter setting locked

Display of temperature on the Fahrenheit scale

Display of temperature on the Celsius scale

Pump on due the cooling function

Pump on due the antifreeze function

Pump on due the function of the vacuum tube

Pump on due the temperature differential (T1-T2)

Output of pump on

T1 sensor position - solar collector

T2 sensor position - pool / thermal reservoir

Indicates the occurrence of overheating T1

Indicates the occurrence of T1 sensor error - solar collector

Indicates the occurrence of T2 sensor error - pool / thermal reservoir

Lock functions enabled

5. OPERATIONS FOR DOMESTIC USER5.1 MAP OF KEYS

The controller has facilitated accesses to the pertinent resources to the user. Following table describing these:

Short press: temperature setting for heating the pool / reservoir

Long press (4 seconds): access to advanced settings

Long press (see F12 parameter): enable/disable lock of functions

Short press: Toggles the display of the temperature (DIF, T1, T2) for 10 seconds

Short press: Toggles the pump mode for MANUAL ON (MAN)

Short press: Toggles the pump mode for AUTOMATIC (AUT)

Short press: Toggles the pump mode for OFF (Disconnected)

5.2 POOL/RESERVOIR HEATING TEMPERATURE (T2 SENSOR)

Sets the comfort temperature of the pool or thermal reservoir (T2). Upon reaching this temperature the water circulation pump is disconnected, avoiding thermal discomfort. To adjust this parameter give a short press on the SET key. Use or keys to adjust the value. To confirm this give a short press on the SET key and the value is saved in the controller's memory. This parameter can be adjusted between 0.0 to 105 °C or between 32 to 221°F.

5.3 PUMP WATER OPERATION MODE

To change the operation mode of the water pump use , and keys. The circulation water pump between the solar collector and thermal pool or reservoir can operate in three different modes. Description below:

Obs.: In the pump mode adjustment, the controller assumes the new Mode 5 seconds after your selection. This is also the time required for the parameter to be stored in its memory.When selected the MAN (manual) mode, the operation mode of the pump remains in this state for a period of 6 hours (fixed time) after the controller assumes the AUT (AUTO) mode. If you want to return to the AUT mode before 6 hours, press the AUT key at any time.

5.4 VIEW OTHER TEMPERATURES

To toggle between the display of the T1 temperature sensor, T2 sensor or differential of these (T1-T2), give short press on key until the desired temperature appears on the display. On digits in the upper display the measured temperature is displayed, and on the digits of the lower display the sensor description.The selected temperature is displayed on the display for 10 seconds, after this preferential indication is displayed again, as set in [,F01] parameter - Preferred Indication.

5.5 LOCK OF FUNCTIONS

For security purposes and to prevent unauthorized users from changing the settings of the controller, there is a lockout of functions feature. With this setting enabled, the parameters cannot be changed, however, can be viewed. In the lock condition, trying to change the value of a parameter is displayed the [,LOC][,,On] message on the display.To enable / disable the locking function should keep pressed the key the time set in parameter [,F12] - Time to lock functions.The icon indicates the user the lock state, when lit indicates that the lock function is active.CLUE: with the lock functions enabled, you avoid children, visitors or curious will change the operation mode or controller parameters. When there is need for a change, just hold down the key to enable / disable this feature.

123456789

1011

MAN Pump Mode Key (Manual)AUT Pump Mode Key (Automatic)OFF Pump Mode Key (Disconnected)Decrease Key SET KeyIncrease KeyPump operation mode indicationSigns of the controllerSolar heating system indicationDigits of the lower displayDigits of the upper display

SETLOC

MAX+

+

+

AUTPUMP

offPUMP

MANPUMP

SET

SET

6. ADVANCED OPERATIONS FOR INSTALLER (TECHNICAL USE)6.1 CHANGE OF CONTROLLER PARAMETERS

Access the settings menu by pressing the SET key for 4 seconds until [FuNc] appears. Then [Code] appears, then press the SET key again, short press. Use the or keys to enter the value of the access code 123, and when ready press the SET key (short press) again.Use the or keys to select the desired function. With a short press on the SET key you can edit its value. Use the or keys to change the value, when ready give a short press the SET key to store the set value and return to the function menu.To exit the menu and return to normal operation (temperature indication) press and hold the SET key (long press) until [----]appears.

MCSOLADVANSWP01-03T-16453

DIFFERENTIAL THERMOSTAT FOR SOLAR HEATING

Ver. 01

A SET

1

2

3

6

5

4

MAX

am pm

SET LOC

AUToff MANPUMP

78

11

9 10

ampm

AUT

PUMP

SWP

AUT= Circulation pump in automatic mode operating as setting of the parameters

MAN= Circulation pump On

OFF= Circulation pump always turned off

Attention: In this mode the pump is maintained turned on , ignoring the protection functions and temperature sensors.

Page 2: MAN Pump Mode Key (Manual) 9 10 3AUT Pump Mode Key ...

When accessing the parameter setting, the upper display will be flashing and the SET icon is displayed, indicating that you can change the parameter value.

6.2 TABLE OF PARAMETERS

Access code

Preferential indication

Differential (T1-T2) to turn on the pump

Differential (T1-T2) to turn off the pump

Antifreeze temperature (T1) to turn on the pump

Minimum time of antifreeze

Overheating temperature (T1) to turn off the pump

Cooling (T2)

Vacuum tube function

Hysteresis of heating temperature of pool / reservoir (T2) (TEMP parameter)

Offset of T1 sensor indication

Offset of T2 sensor indication

Time to lock functions

Display backlight intensity

Min Max Unit Min Max Unit

CELSIUS FAHRENHEIT

Fun

[CoDE]

[,F01]

[,F02]

[,F03]

[,F04]

[,F05]

[,F06]

[,F07]

[,F08]

[,F09]

[,F10]

[,F11]

[,F12]

[,F13]

6.3 DESCRIPTION OF PARAMETERS

[CoDE] – Access code (123):Required if you want to change the parameters for advanced configuration. To view the set parameters only, it is not necessary to insert this code.

[,F01] – Preferential indication:This function allows you to choose the temperature that would normally be displayed on the display. You can select between:

[,DIF]– T1-T2 Differential. Shows how many degrees is the difference between the solar collector (T1) and the pool or thermal reservoir (T2).[,,T1]– Temperature of collectors (T1).[,,T2]– Temperature of pool/thermal reservoir (T2).

[,F02] – Differential (T1-T2) to turn on the pump:Allows you to configure the temperature difference between the solar collector and the pool / thermal reservoir to trigger the circulation pump. As the collectors receive energy, the T1 sensor temperature increases when this temperature is above a certain value of the T2 sensor temperature, the pump is turned on and circulates the heated water, storing it in the reservoir.

[,F03] – Differential (T1-T2) to turn off the pump:Allows you to configure the temperature difference between the solar collector and the pool / thermal reservoir to turn off the circulation pump. With the pump on, the temperature difference between the collector and the reservoir (T1-T2) tends to decrease. When this value falls to a certain value, the pump is turned off, stopping the water flow.

[,F04]– Antifreeze temperature (T1) to turn on the pump:When the temperature of collectors (T1) is too low (ex.: winter nights) the pump is turned on, depending on the temperature set this parameter to prevent the water from freezing in the solar collector and damaging them. The hysteresis of this control is fixed and set at 2.0ºC. To disable this function moves the setting to the minimum until [,,no] appears.

[,F05] – Minimum time of antifreeze:This minimum time of pump on serves as security to ensure that water passes by all collectors. Even if the temperature of T1 sensor exceeds the antifreeze temperature (parameter [,F04]), the controller regards the time set in this parameter. This function is widely used in large projects by the amount of installed plates. To disable this function moves the setting to the minimum until [,,no]appears.

[,F06]– Overheating temperature (T1) to turn off the pump:When the temperature in the collector (T1) is above the value set in this parameter, the pump is turned off to prevent the heated water circulating through the pipes and damaging them, if PVC pipes are used for example. The hysteresis of this control is fixed and set at 2.0ºC.

[,F07] – Cooling (T2):Aims to cool the pool / thermal reservoir at night when the heating temperature ([temp] parameter) is exceeded and the difference between the collector (T1) and reservoir (T2) reaches -4.0°C (fixed). The pump is then turned on, using the collector as a radiator to cool the pool water. When the differential (T1-T2) is less than -2,0ºC (fixed) or temperature (T2) falls below the heating temperature of the reservoir ([temp] parameter) the pump is switched off.

[,F08] – Vacuum tube function:When this feature is enabled, drives the pump for 20 seconds (fixed) every 30 minutes (fixed) that the pump is switched off, while the collector temperature (T1) is above 20.0°C (fixed) and the temperature differential (T1-T2) is positive.There are models of vacuum tube collectors that do not allow direct measurement of the collector temperature, for lack of foresight for immersion sensors.

For a correct measurement of the water temperature at the outlet of the collector is necessary that a minimum water flow occurs. For this, the solar circuit must activate the pump at regular intervals, so that heated water from the collector reaches the sensor T1.Note: The controller prioritizes the protection settings (overheating), ignoring the function of the vacuum tube, upon the occurrence thereof.

[,F09] – Hysteresis of heating temperature of pool / reservoir (T2) [temp] parameter):If the pump is stopped by heating of the reservoir ([temp]), using this function you can define a temperature range within which the pump will remain off.For example: If adjusted [temp]=[,30.0]and [,F09]=[,,1.0], pool / thermal reservoir heating will turn off when the temperature of the T2 sensor reaches 30.0°C, and again just calling to heat when it drops below 29.0°C (30.0 - 1.0 = 29.0).

[,F10]– Offset of T1 sensor indication:[,F11]– Offset of T2 sensor indication:To compensate possible misreading of T1 (collector) and T2 (reservoir) sensors from sensor replacement or modification of cable length.

[,F12] – Time to lock functions:Sets the time that must be held down the increment key to lock / unlock the parameter changes. For further information see section 5.5 - Lock of Functions To disable this function moves the setting to the minimum until [,,no] appears.

[,F13] – Display backlight intensity:Sets the backlight intensity of the display to set its contrast.

7. SIGNALS

Notes:

am pm

- If no 123 code has been inserted, when accessing the parameter setting the icon will be displayed on upper display, indicate that the setting is locked.

- By blocking the active functions to press or keys to change the value of the function, the controller displays the [,LOC] [,,On] message on display and you cannot make the parameter adjustment.

SET

LOC

LOC

am

Note: In the event of any error information the controller signals the user, briefly flashing the backlight of the display, to call attention.

- Reason: 1 sensor disconnected or out of range.

- Reason: 2 sensor disconnected or out of range.

StandardDescription

0

DIF

1.0

1.0

no (-19)

no (0)

0.0

Off

Off

0.1

-5.0

-5.0

no (3)

1

999

T2

40.0

40.0

10.0

600

200

On

On

20.0

5.0

5.0

30

10

-

-

ºC

ºC

ºC

s

ºC

-

-

ºC

ºC

ºC

s

-

0

T2

8.0

4.0

8.0

60

90.0

Off

Off

1.0

0.0

0.0

4

8

0

DIF

1

1

no (-2)

no (0)

32

Off

Off

1

-9

-9

no (3)

1

999

T2

72

72

50

600

392

On

On

36

9

9

30

10

-

-

ºF

ºF

ºF

s

ºF

-

-

ºF

ºF

ºF

s

-

0

T2

14

7

46

60

194

Off

Off

1

0

0

4

8

- Activity: Check connections and sensor operation.

- Activity: Check connections and sensor operation.

LOC

Standard

6.4 UNIT SELECTION

To set the temperature unit that will operate the instrument, you must access the [Code] function (see Section 6.1 for information about accessing this function) insert 231 and press the SET key. The user can select the unit by pressing or keys, where the messages are alternate. Press the SET key to confirm the desired unit. [,=C,]or[,=F,]

Then the message [----] is displayed and the unit corresponding icon will turn {or }

on.Note: When the unit is replaced, the controller loads the default values for its parameters, [,FAC], being necessary to perform the configuration of the same.

- Activity: Contact the technician responsible for installation.

- Activity: Contact the technician responsible for installation.

Page 3: MAN Pump Mode Key (Manual) 9 10 3AUT Pump Mode Key ...

ENVIRONMENTAL INFORMATIONPackaging:The materials used in the packaging of Full Gauge products are 100% recyclable. Try to perform disposal through specialized recyclers.

Product:The components used in Full Gauge controllers can be recycled and reused if disassembled by specialized companies.

Disposal:Do not incinerate or dispose the controllers that have reached the end of their service as household garbage. Observe the laws in your area regarding disposal of electronic waste. If in doubt, please contact Full Gauge Controls.

WA

RR

AN

TY -

FULL

GA

UG

E C

ON

TRO

LS

Products manufactured by Full Gauge Controls, as of May 2005, have a two (02) yearwarranty, as of the date of the consigned sale, as stated on the invoice. They are guaranteed against manufacturing defects that make them unsuitable or inadequate for their intended use.

EXCEPTIONS TO WARRANTYThe Warranty does not cover expenses incurred for freight and/or insurance when sendingproducts with signs of defect or faulty functioning to an authorized provider of technical

support services. The following events are not covered either: natural wear and tear of parts; external damage caused by falls or inadequate packaging of products.

LOSS OF WARRANTYProducts will automatically lose its warranty in the following cases:- The instructions for assembly and use found in the technical description and installation

procedures in Standard IEC60364 are not obeyed;- The product is submitted to conditions beyond the limits specified in its technical

description;- The product is violated or repaired by any person not a member of the technical team of

Full Gauge Controls;- Damage has been caused by a fall, blow and/or impact, infiltration of water, overload

and/or atmospheric discharge.USE OF WARRANTY

To make use of the warranty, customers must send the properly packaged product to FullGauge Controls together with the invoice or receipt for the corresponding purchase. As

much information as possible in relation to the issue detected must be sent to facilitate analysis, testing and execution of the service.

These procedures and any maintenance of the product may only be provided by Full Gauge Controls Technical Support services in the company's headquarters at Rua Júlio de Castilhos, 250 - CEP 92120-030 - Canoas - Rio Grande do Sul – Brasil

Rev. 03

9. IMPORTANTAccording to the chapters of norm IEC 60364:1: Install protector against overvoltage on the power supply.2: Sensor cables and signal cables of the computer may be joined, but not in the same electric conduit through which the electric input and the activation of the loads run.3: Install transient suppresors (RC filters) parallel to the loads as to increase the product life of the relays.

Contact suppressor connection diagram

Sup

pres

sor

A1

A2

A1 and A2 are the contactor coils.

Diagram for suppressor installation for direct drive load inputs

Load

Sup

pres

sor

For direct activation the maximumspecified current should be takeninto consideration.

Suppressors on offer from Full Gauge Controls

8.3 ELECTRICAL CONNECTIONS

1 2 3 4 5 6 7 8 9 10 11

PUMPPOWERSUPPLY

PUMP

115 Vacor

230 Vac

0

Power supply

NOTE: check supply as product model

8. INSTALLATION8.1 SUPERIMPOSED INSTALLATION

Push the bottom openings necessary for the passage of cables;

Attach the controller to the wall using the screws and plugs provided;

Make the electrical connections of the controller;

For a better finish install X system type channels to run cables;

Place the protective cover of the electrical connections and secure it with the screw (included in package).

8.2 INSTALLATION OF 4x2 BOX

The top screw must not be screwed completely, for engaging the controller. After fitting the controller on the top screw, secure it with the lower screw;

Push the rear openings necessary for the passage of cables;

Route the cables through the openings as controller connections;

Secure the controller in 4x2 box using the screws provided;

Place the protective cover of the electrical connections and secure it with the screw (included in package).

Make the electrical connections of the controller;

The top screw must not be screwed completely, for engaging the controller. Afterfitting the controller on the top screw, secure it with the lower screw;

Copyright 2013 All rights reserved.

Remove the protective cover of the connections at the bottom of the controller;

Remove the protective cover of the connections at the bottom of the controller;

A qualified technician must performthe installation of the device.

DO DON’TsThe controller MUST be installed: - indoors, in a dry environment;

- away from electromagnetic fields;- in a ventilated place, free from flammable liquids and gases;- protected by a circuit breaker of appropriate specification for the installed load.

The controller MUST NOT be installed: - in wet places;

- exposed to sunlight or rain;- in saunas, machine rooms or bathrooms.

Turn off the network before removing

the protection cover.

1

2

3

4

5

6

1

2

3

4

5

6

s

Failure to not comply the warnings will cause loss of warranty, equipment and / orphysical damage.

Note: The length of the sensor cable can be increased by the user up to 200 meters using PP 2 x 24 AWG cable.The sensor with white cable must be installed in the solar collector, it supports a temperature of 200 º C.

SENSOR T1WHITE CABLE

(COLLECTORS)

SENSOR T2 BLACK CABLE (RESERVOIR)