Man 3780

1
3780 Rail pressure: High controller output idling Monitoring for rail pressure controller idling System reaction: Engine can stop due to insufficient rail pressure SPN 3780 RAIL PRESSURE: HIGH CONTROLLER OUTPUT IDLING Fault display: Central fault lamp flashes red whilst driving and when stationary, stop indication on display (priority 1) Monitoring strategy: Monitoring for rail pressure controller idling Effect of fault: Engine can stop due to insufficient rail pressure Refer to the diagrams for the vehicle in question Testing Measurement Correcting the fault Fuel system Check according to hydraulic test step list See hydraulic test step list Metering unit (MProp) Resistance measurement between pin A08 and A10 Nominal value: 2.5 – 4.5 Check lines Check plug connectors Rail pressure sensor Check the plug connection on the sensor for loose contact Repair or renew the connector Renew rail pressure sensor

description

MAN3780

Transcript of Man 3780

Page 1: Man 3780

3780

Rail pressure: High controller output idling

Monitoring for rail pressure controller idlingSystem reaction: Engine can stop due to insufficient rail pressure

SPN 3780 RAIL PRESSURE: HIGH CONTROLLER OUTPUT IDLING

Fault display:Central fault lamp flashes red whilst driving and when stationary, stop indicationon display (priority 1)

Monitoringstrategy:

Monitoring for rail pressure controller idling

Effect of fault: Engine can stop due to insufficient rail pressure

Refer to the diagrams for the vehicle in question

Testing Measurement Correcting the fault

Fuel system Check according to hydraulic test step list• See hydraulic test step

list

Metering unit(MProp)

Resistance measurement between pin A08and A10Nominal value: 2.5 – 4.5 Ω

• Check lines • Check plug connectors

Rail pressuresensor

Check the plug connection on the sensor forloose contact

• Repair or renew theconnector• Renew rail pressure

sensor