    Preface

    Maintenance Experience

    Editorial Committee

    Maintenance Experience

    Newsroom

    Address: ZTE Plaza, Keji Road South, Hi-TechIndustrial Park, Nanshan District,

    Shenzhen, P.R.China

    Postal code: 518057

    Contact: Song Chunping

    Tel: +86-755-26770600, 26771195

    Fax: +86-755-26772236

    Document Support Email: [email protected]

    Technical Support Website: http://ensupport.zte.

    com.cn

    Maintenance Experience

    Bimonthly for Data Products

    No.13 Issue 160, April 2009

    In this issue of ZTE's Maintenance Experience, we continue

    to pass on various eld reports and resolutions that are gathered

    by ZTE engineers and technicians around the world.

    The content presented in this issue is as below:

    One Special Document

    Six Maintenance Cases of ZTE's Data Products

    Have you examined your service polices and procedures

    lately? Are you condent that your people are using all the tools

    at their disposal? Are they trained to analyze each issue in a

    logical manner that provides for less downtime and maximum

    customer service? A close look at the cases reveals how to iso-

    late suspected faulty or mis-congured equipment, and how to

    solve a problem step by step, etc. As success in commissioning

    and service is usually a mix of both discovery and analysis, we

    consider using this type of approach as an example of success-

    ful troubleshooting investigations.

    While corporate leaders maintain and grow plans for expan-

    sion, ZTE employees in all regions carry out with individual ef-

    forts towards internationalization of the company. Momentum

    continues to be built, in all levels, from ofce interns to veteranengineers, who work together to bring global focus into their

    daily work.

    If you would like to subscribe to this magazine (electronic

    version) or review additional articles and relevant technical mate-

    rials concerning ZTE products, please visit the technical support

    website of ZTE Corporation (http://ensupport.zte.com.cn).

    If you have any ideas and suggestions or want to offer your

    contributions, you can contact us at any time via the following

    email: [email protected].

    Thank you for making ZTE a part of your telecom experience!

    Maintenance Experience Editorial Committee

    ZTE Corporation

    April, 2009

    Director: Qiu WeizhaoDeputy Director: Chen Jianzhou

    Editors:

    Jiang Guobing, Zhang Shoukui, Wu Feng, Yuan

    Yufeng, Tang Hongxuan, Li Gangyi, Song Jianbo,

    Tian Jinhua, Wang Zhaozheng, Liu Wenjun,

    Wang Yapping, Lei Kun, Wang Tiancheng,

    Ge Jun, Yu Qing, Zhang Jiebin, Fang Xi

    Technical Senior Editors:

    Hu Jia, Bai Jianwen

    Executive Editor:

    Zhang Fan

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    3/32

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    4/32

    Maintenance Experience2

    April 2009 Issue 160

    NetNumen N31 Overview

    At present, network techniques de-

    velop vigorously. More and more key ap-

    plications and services are established on

    the base of data network. Therefore, it is

    very important to ensure that the network

    works normally and efficiently. Network

    operators, Internet service providers and

    enterprises must implement effective man-

    agements and plans to the network system

    to meet the growing requirements of users

    to the maximum extent. To establish, de-

    ploy and use the network quickly, as well

    as keep the network running conveniently,

    a data network management system with

    powerful functions, good extensibility and

    high performance is recommended.

    On the other hand, due to the fast

    changing market, declining product life

    cycle and increasing market launch press,

    network operators are facing intense com-

    petition. Therefore, requirement of effec-

    tive network management system is need-

    ed in order to decrease operating cost and

    improve network quality.

    In addition, considering the increasing

    software development cost and demand

    for supporting different operating systems

    and hardware platforms, network opera-

    tors have to nd a technique that can help

    them to improve productivity greatly. In

    NetNumen N31 Unied

    Management System Ye Dezhong, Lu yinghua / ZTE Corporation

    the current situation, technique and demand keepschanging continually. It is important for most equip-

    ment manufacturers and software developers to

    make their product support different operating

    systems and hardware platforms. To meet the

    changing requirements of their users, equipment

    manufacturers must provide a network manage-

    ment system that can run in different platforms and

    support Web.

    ZTE holds the pulse of the times and develops

    NetNumen N31 Unied Management System. This

    is a high customization cross-platform network

    management system of carrier class. It is on the

    base of new Internet technique and it is designed

    according to rules from bottom to top. It can be

    used to manage all ZTE data products. It covers

    network element management, network manage-

    ment and service management.

    NetNumen N31 Functions

    NetNumen N31 has the following functions.

    1. Providing unied network management.

    NetNumen N31 can be used to manage all

    ZTE data products.

    NetNumen N31 covers Management levels

    of network element, network and service,

    providing perfect network management

    functions.

    NetNumen N31 can be integrated with

    network management systems of NGN and

    ADSL to implement unied management.

    Key words:NetNumen N31

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    5/32

    Data Products

    www.zte.com.cn

    3

    2. Providing different management privileges

    and implementing management in different areas.

    Users can access the management system in dif-

    ferent areas with different management privileges.

    3. Supporting different platforms and different

    databases.

    NetNumen N31 uses J2EE architecture

    and it is developed in JAVA. Therefore it

    supports different platforms and operating

    sys tems such as UNIX, LINUX and

    WINDOWS.

    NetNumen N31 supports databases such

    as MSSQL, SYBASE and ORACLE.

    4. Providing convenient extension and up-

    grade.

    NetNumen N31 uses modularization structure.

    It is with good extension and upgrade ability.

    5. Providing special management functions.

    Policy management

    Fast network automatic discovery

    Fault processing expert base

    Report processing

    Conguration management based on task

    Network statistics6. Supporting localization.

    NetNumen N31 supports Chinese and English.

    Users can select the language during the installa-

    tion to implement localization management.

    7. Complying with high standards

    NetNumen N31 complies with TMN series sug-

    gestions defined by ITU-T. NetNumen N31 also

    complies with a series of network management

    protocols defined in RFC and network manage-

    ment suggestions in TMF.

    8. Providing high security.

    NetNumen N31 provides perfect access

    privilege control.

    NetNumen N31 provides perfect security

    log records.

    9. Providing high reliability.

    NetNumen N31 supports local backup and

    remote recovery.

    NetNumen N31 is with good fault tolerance

    ability. When a server in the system

    is down, other servers can take

    over the tasks. This ensures that

    the services will not be intermitted.

    NetNumen N31 provides good

    system management ability. Data

    information of NetNumen N31

    management sys tem can be

    monitored.

    10. Providing good openness.

    NetNumen N31 supports standard

    SNMP and it provides CORBA interface,

    SNMP interface and TL1 interface. NetNu-

    men N31 can be integrated with third party

    systems, providing convenience for ofces

    to implement OSS system application.

    11. Providing perfect after sale ser-

    vice.

    NetNumen N31 uses are provided with

    247 after sale service of ZTE.

    The management functions of NetNu-

    men N31 management system cover four

    layers of TMN management layers, includ-

    ing Network Element (NE) layer, NE man-agement layer, network management layer

    and service management layer. The core

    is the function modules in network man-

    agement layer. The structure of NetNumen

    N31 management system is shown in

    Figure 1.

    Figure 1. Structure of NetNumen N31 Management System

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    6/32

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    7/32

    Data Products

    www.zte.com.cn

    5

    Malfunction Situation

    When users install SQL, the system may usually prompt installation failure. The reason is that

    users have installed database before but the database les were not deleted completely.

    Solution

    To delete the database les completely, perform the following steps.1. Uninstall the database program through Add orRemove Programs in Control Panel.

    2. Delete the whole Microsoft SQL Server le manually.

    3. Click StartRun and input regedit to open RegistryEditor, and then delete the follow-

    ing items.

    HKEY_CURRENT_USER\Software\Microsoft\Microsoft SQL Server

    HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Microsoft SQL Server

    HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\MSSQLServer

    4. Reboot the system.

    5. Install SQL again.

    SQL Server Installation Failure Wang Xinlin / ZTE Corporation

    Key words: SQL, installation failure

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    8/32

    Maintenance Experience6

    April 2009 Issue 160

    Malfunction Situation

    ZXR10 2818S switches work as mem-

    ber switches in a cluster. As shown inFigure 1, switches are displayed as CO

    in NetNumen N31 network management

    platform. However, in normal situation,

    switches must be displayed as C. When

    switches are displayed as CO, there is no

    telnet option in the shortcut menu if users

    right-click the switches.

    Member Switch in Cluster

    Displaying as CO Zhang Jintao / ZTE Corporation

    switch or an external member switch of the cluster.

    An internal member switch of a cluster

    appears in both Device table and Group

    member table.

    An external member switch of a cluster

    appears only in Device table but not in

    Group member table.

    Sometimes, users may find that a switch ap-

    pears both in Device table and Group member ta-

    ble, but it is displayed as CO on network manage-

    ment server. The reason is that that switch worked

    as a member switch, the link between the member

    switch and the command switch was down and a

    moment later it was recovered, but states on the

    command switch was not refreshed. Users are

    recommended to implement topology collection to

    refresh the state on the command switch.

    Solution

    To solve the problem, perform the following

    steps.

    1. Delete the member switches on the com-

    mand switch and then add the member switches

    again. This ensures that the state of member

    switches in Group member table is up and users

    can log in to member switches through command

    switch.

    2. Input ztp start command on command

    switch to collect topology information again.

    3. Right-click the command switch in topol-

    ogy management view and then select Update

    State in the shortcut menu. The member switches

    are displayed as C.

    Figure 1. Member Switch in Cluster Displaying as CO

    Malfunction Analysis

    When the switch is displayed as C, it is

    an internal member switch of the cluster.

    When the switch is displayed as CO, it isan external member switch of the cluster.

    In a switch cluster, there are two impor-

    tant tables on the command switch, Device

    table and Group member table. Users can

    view the information in the two tables with

    show ztp device-list command and show

    group membercommand.

    The following rules are used to judge

    whether a switch is an internal member

    Key words: cluster management, CO, C, ZTP, NetNumen N31

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    9/32

    Data Products

    www.zte.com.cn

    7

    Malfunction Situation

    There are two NEs (ZXR10 T64G) with

    the same name Miriyalguda in NetNu-

    menN31 network management system.

    They are in different groups, as shown in

    Figure 1.

    NE MAC Address Collision Zhou Hongwei / ZTE Corporation

    address collision.

    Engineers logged into the two NEs and

    checked the MAC addresses. Engineers found that

    the MAC address were the same indeed. The MAC

    address was 00d0.d0c7.ffe1, as shown in Figure 2.

    Figure 1. Same NEs

    Figure 2. MAC Address

    Malfunction Analysis

    Engineers checked the information

    of the NEs. The NEs had the same infor-

    mation, including IP address. Engineers

    considered that it may be caused by MAC

    Solution

    The same MAC address on two NEs resulted

    in the MAC address collision in NetNumenN31

    network management system. Therefore, it was

    Key words: NetNumenN31, MAC address collision

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    10/32

    Maintenance Experience8

    April 2009 Issue 160

    necessary to modify the MAC address in

    one of the NEs.

    To modify the MAC address on one

    NE through remote connection, engineers

    took the following steps.

    1. Engineers defined an address

    segment range on service interface of the

    switch with the following command.

    ZXR10(config-increte)#mac-base-addr

    add master / slave { 8 |

    16 | 32 }

    8, 16 and 32 were used to specify the

    MAC address range. If the MAC address

    range was set as 8, the last three bits of

    MAC address must be 0. If the MAC ad-

    dress range was set as 16, the last four

    bits of MAC address must be 0. If the MAC

    address range was set as 32, the last ve

    bits of MAC address must be 0.

    After dening address segment range

    on service interface, engineers input the

    following command.

    ZXR10(config-increte)#mac-base-addr

    enable master/slave

    After this command was configured,

    MAC address was distributed in new mode

    and it was saved in nvram of the switch.

    After the switch was rebooted, the new

    MAC address distribution mode would beloaded in memory and take effect.

    2. Engineers defined an address

    segment range on administration interface

    of the switch with the following command.

    ZXR10(config-increte)#mac-base-addr add

    master/slave mng { 1-4 }

    At present, four MAC address could be speci-

    ed on administration interface. However, only one

    administration interface was needed on G series

    switches. Therefore it was necessary to congure

    one MAC address. It was not necessary to set the

    MAC address for administration interface according

    to the address segment range dened on service

    interface.

    After defining address segment range on ad-

    ministration interface, engineers input the following

    command.

    ZXR10(config-increte)#mac-base-addr enable

    master/slave

    After this command was configured, MAC ad-

    dress was distributed in new mode and it was

    saved in nvram of the switch. After the switch was

    rebooted, the new MAC address distribution mode

    would be loaded in memory and take effect.

    3. Engineers saved the above conguration.

    It was not necessary to save the conguration

    manually. After the configuration, the above com-

    mands were saved in nvram of the switch automat-

    ically. They would take effect after the switch was

    rebooted.

    The above configuration also could be saved

    manually with the following command.

    ZXR10# write nvram

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    11/32

    Data Products

    www.zte.com.cn

    9

    Malfunction Situation

    After the software version of T160G in a city

    is upgraded, services running on a DSLAM con-

    nected to this T160G were interrupted and it failed

    to access NMS of the DSLAM. T160G provides L2

    transparent transmission for services of DSLAM.

    NMS of DSLAM and that of T160G were in the

    same network segment.

    The network topology is shown in Figure 1.

    tion was normal.

    2. Engineers viewed MAC entries of

    T160G and they found that MAC address

    learning was normal, as shown below.

    T160G#show mac interface fei_3/43

    Total MAC address : 96

    Flags: vid -VLAN id,stc-static, per-permanent, toS-to-

    static, srF-source lter,dsF-destination lter,time-day:hour:min:sec Frm-mac from where:0,drv:1,cong:2,V

    PN:3,802.1X:4,micro:5,dhcp

    MAC_Address port vid stc per toS srF dsF Frm Time---------------------------------------------------------------------------------------0014.6c24.acf3 fei_3/43 123 0 0 0 0 0 0 0:01:06:30

    0810.170c.551f fei_3/43 123 0 0 0 0 0 0 0:01:14:42

    00e0.fc0e.4fe2 fei_3/43 6 0 0 0 0 0 0 0:01:05:40

    Figure 1. Network Topology Diagram

    Malfunction Analysis

    To nd out the problem, engineers took the fol-

    lowing steps.

    1. Engineers viewed alarm log of T160G and

    they found that there was no problem. All informa-

    3. Engineers viewed ARP informa-

    tion of T160G. They found that ARP infor-

    mation of peer DSLAM could be learned.

    IP address of DSLAM was 221.9.122.6, as

    shown below.

    T160G#show arp int vlan 6

    Arp protect mac is disabled

    The count is 2

    IPAddress Age(min) HardwareAddress VLAN InterfaceID SubInterface-----------------------------------------------------------------------------------------221.9.122.6 0 00e0.fc0e.4fe2 vlan6 6 fei_3/43

    221.9.122.5 - 00d0.d0c0.5721 vlan6 N/A N/A

    Key words: network interruption, MAC address offset

    Network Interruption Caused byMAC Address OffsetNetwork Interruption Caused byMAC Address Offset Ye Wei / ZTE Corporation

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    12/32

    Maintenance Experience10

    April 2009 Issue 160

    4. Engineers viewed direct-connect-

    ed route 221.9.122.6. The entries in hard-

    ware forwarding table were correct, as

    shown below.

    T160G#sho ip forwarding hostrt np 3 221.9.122.6

    Host routing table:

    Flags:Int-internal label,Ext-external label,Tr-trunk ag,

    Mf-mpls ag,Vpn-vpn id,

    Loc-location(SW--switch,NP--network processer)

    IpAddr/Mask Mod/Port Vlan/Tag Int/Ext DestMac Tr/Mf/Vpn/Loc-------------------------------------------------------------------------------------221.9.122.6/32 3/43 6/1 untagged 00e0.fc0e.4fe2 0/0/0/SW

    5. Engineers pinged to NMS address of

    DSLAM through T160G, as shown below.

    T160G#ping 221.9.122.6

    sending 5,100-byte ICMP echos to

    221.9.122.6,

    timeout is 2 seconds.

    .....

    Success rate is 0 percent(0/5).

    T160G#sho mac int gei_2/4

    Total MAC address : 27

    Flags: vid-VLAN id,stc-static,per-permanent,toS-to-static,srF-source lter,dsF-destination lter,time-day:hour:min:sec

    Frm-mac from where:0,drv;1,cong;2,VPN;3,802.1X;4,micro;5,dhcp

    MAC_Address port vid stc per toS srF dsF Frm Time-----------------------------------------------------------------------------------------------00e0.fc5d.09c0 gei_2/4 196 0 0 0 0 0 0 0:02:58:08

    00e0.fc5d.09c0 gei_2/4 166 0 0 0 0 0 0 0:03:00:40

    00e0.fc5d.09c0 gei_2/4 55 0 0 0 0 0 0 0:12:31:08

    00e0.fc5d.09c0 gei_2/4 194 0 0 0 0 0 0 0:00:18:13

    00e0.fc5d.09c0 gei_2/4 105 0 0 0 0 0 0 0:09:32:49

    00e0.fc5d.09c0 gei_2/4 193 0 0 0 0 0 0 0:12:39:22

    00e0.fc5d.09c0 gei_2/4 121 0 0 0 0 0 0 0:12:39:25

    00e0.fc5d.09c0 gei_2/4 104 0 0 0 0 0 0 0:12:39:25

    00e0.fc5d.09c0 gei_2/4 165 0 0 0 0 0 0 0:12:39:25

    00e0.fc5d.09c0 gei_2/4 167 0 0 0 0 0 0 0:12:39:24

    00e0.fc5d.09c0 gei_2/4 178 0 0 0 0 0 0 0:12:39:26

    00e0.fc5d.09c0 gei_2/4 198 0 0 0 0 0 0 0:12:39:26

    00e0.fc5d.09c0 gei_2/4 123 0 0 0 0 0 0 0:12:39:26

    6. Engineers viewed MAC address

    learning on T160G interface connected

    to HW5200G. MAC address learning was

    normal, as shown below.

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    13/32

    Data Products

    www.zte.com.cn

    11

    The above fault information showed that MAC

    address learning on T160G was normal and few

    forwarding entries and ARP learning were also

    correct. While after upgrade, services and NMSs

    of the other DSLAM devices were normal. This

    indicated that it was not the problem of T160G.

    After the upgrade, fault occurred and the difference

    before and after upgrade was that MAC address of

    T160G offsets for one bit. It was supposed that IP

    address and MAC address of T160G were bound

    in DSLAM.

    Solution

    Engineers checked configuration of DSLAM.

    They found that MAC binding was not set and the

    learnt MAC address was the old MAC ad-

    dress of T160G. Due to software problem,

    MAC learning and address aging func-

    tion of DSLAM got invalid. After rebooting

    DSLAM, services ran normally.

    Experience Summary

    After upgrade, MAC address of T160G

    changed and the faulty DSLAM happened

    to have problem in MAC learning (MAC

    address aging function and MAC learn-

    ing got invalid), which brought interruption

    of services. After engineers reboot theDSLAM, MAC address learning function

    restored and services ran normally.

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    14/32

    Maintenance Experience12

    April 2009 Issue 160

    Network Topology

    DSLAM and switches are down-linked

    to 3952. SVLAN is configured on 3952.

    Transparent transmission is congured on

    T64G. Leased-line users, NM and other

    services are terminated on T64E. PPPOE

    dial-in users are terminated on BAS. Net-

    work topology is shown in Figure 1.

    Surng Internet in MAN Ye Wei / ZTE Corporation

    The range of inner vlan id for PPPOE dial-in

    user: for DSLAMs, 100 vlans are allocated

    to each device with id range to be 101-500;

    for switches, 40 vlans are allocated to each

    device with id range to be 501-2500.

    Malfunction Situation

    The speed of surng internet at peak hours was

    slow. Delay in sending ping packet was high, and

    some packets were lost. At this peak time devices

    ran normally, and other operational functions of the

    devices was normal.

    Malfunction Analysis

    To nd out the problem, engineers took the fol-

    lowing steps.

    1. Engineers viewed system CPU utilization

    when the speed of surfing internet was slow to

    make sure whether CPU utilization was too high to

    inuence running of system. The result was shown

    below.

    Figure 1. Network Topology

    The planning of VLAN is as follows:

    Leased line: 3001-3500

    Network management system: 99

    The range of outer vlan id for

    PPPOE dial-in user: 100

    Key words: QinQ, VLAN, uplink port, customer port

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    15/32

    Data Products

    www.zte.com.cn

    13

    The above information showed that the CPU

    was normal.

    2. Engineers viewed traffics on interface.

    Traffics on port may also influence the speed ofsurng internet. If the trafcs were too large, con-

    gestion would occur, and then the speed of surng

    internet could also be slowed down. Interface trafc

    information is shown below.

    ZXR10#show interface fei_1/1

    fei_1/1 is up, line protocol is up

    Description is none

    Keepalive set:10 sec

    The port is electricDuplex full

    Mdi type:auto

    VLAN mode is access, pvid 4094 BW 100000

    Kbits

    Last clearing of "show interface" counters never

    120 seconds input rate: 3403245 Bps, 3117 pps

    120 seconds output rate: 1122389 Bps, 11912

    pps

    Interface peak rate:

    input 8120382 Bps, output 12420382 BpsInterface utilization: input 29%, output 90%

    Input:

    Packets: 19028174612 Bytes: 24122478262892

    Unicasts: 18709469101 Multicasts: 19281980

    Broadcasts: 299188371 Undersize: 230911

    Oversize: 3247 CRC-ERROR: 9

    Dropped: 1091 Fragments: 0

    Jabber: 1002 MacRxErr: 0

    Output:

    Pack e t s : 142123550101 By t e s :

    182329420262394

    Unicasts: 56909126342 Multicasts:

    729262387

    Broadcasts: 84485161372 Collision: 0

    LateCollision: 0

    Total:

    64B: 772661029 65-127B: 803872612

    128-255B: 1292984228 256-511B:

    2374859862

    512-1023B: 63467072821 1024-1518B:

    92427412536

    The above information showed that

    trafcs on customer port in outgoing direc-

    tion were large and it caused congestion.

    Engineers viewed traffic information on

    other interfaces. They found that trafcs in

    outgoing direction of other interfaces were

    also large.

    3. Engineers viewed traffics on up-

    link interface, as shown below.

    ZXR10#show interface gei_2/1

    gei_2/1 is up, line protocol is up

    Description is none

    Keepalive set:10 sec

    The port is electric

    Duplex full

    Mdi type:auto

    VLAN mode is access, pvid 4094 BW

    ZXR10#show processor

    M: Master processor

    S: Slave processor

    Peak CPU: CPU peak utility measured in 2 minutes

    PhyMem: Physical memory (megabyte)

    Panel CPU(5s) CPU(30s) CPU(2m) Peak CPU PhyMem Buffer Memory

    MP(M) 1 20% 19% 18% 40% 256 0% 35.902%

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    16/32

    Maintenance Experience14

    April 2009 Issue 160

    1000000 Kbits

    Last clearing of "show interface" coun-

    ters never120 seconds input rate : 29123012 Bps,

    29081 pps

    120 seconds output rate: 14133829 Bps,

    13909 pps

    Interface peak rate :

    input : 50234251 Bps, output 5292182

    Bps

    Interface utilization: input 28%, output

    19%

    The above information showed that

    trafcs on uplink port were normal.

    4. Engineers viewed alarm informa-

    tion. No abnormal alarm was presented

    and no MAC floating alarm occurred.

    Therefore, it was not loop that caused

    broadcast storm.

    5. Engineers analyzed configuration

    on the device. QinQ conguration is shown

    below.

    Port conguration is shown below.

    ZXR10(cong)#show run interface fei_1/1

    description TO-DS01

    no negotiation auto

    switchport mode hybrid

    switchport hybrid native vlan 4094

    switchport hybrid vlan 99 tag

    switchport hybrid vlan 100 untag

    switchport hybrid vlan 3001-3010 tag

    switchport qinq customer

    ZXR10(cong)#show run interface fei_1/2

    description TO-DS02

    no negotiation auto

    switchport mode hybrid

    switchport hybrid native vlan 4094

    switchport hybrid vlan 99 tag

    switchport hybrid vlan 100 untag

    switchport hybrid vlan 3011-3020 tag

    switchport qinq customer

    ZXR10(cong)#show run interface fei_2/1

    description to-T64G

    no negotiation auto

    hybrid-attribute ber

    switchport mode hybrid

    switchport hybrid native vlan 1

    switchport hybrid vlan 99 tag

    switchport hybrid vlan 101-150 tag

    switchport hybrid vlan 3001-3500 tag

    switchport hybrid vlan 501-2500 tag

    switchport hybrid vlan 4094 untag

    switchport qinq uplink

    ZXR10(cong)#show vlan qinq

    Session Customer Uplink In_Vlan Ovlan Helpvlan

    -------------------------------------------------------------------

    1 fei_1/1 gei_2/1 101-200 100

    2 fei_1/2 gei_2/1 201-300 100

    3 fei_1/3 gei_2/1 301-400 100

    4 fei_1/4 gei_2/1 401-500 100

    5 fei_1/5 gei_2/1 501-540 100

    6 fei_1/6 gei_2/1 541-580 100

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    17/32

    Data Products

    www.zte.com.cn

    15

    Malfunction Situation

    As shown in Figure 1, ACL

    was applied on interface Fei_1/1

    of ZXR10 3928 switch to forbid

    PC to ping to 3928. The congu-

    ration failed but still PC could

    ping 3928 successfully.

    With the above information results, engineers

    found that native VLAN on each port was Helperv-

    lan 4094. Double-tagged services were implement-

    ed through VLAN QinQ. Therefore, MAC learning

    was in Helpervlan 4094, and the VLAN 100 would

    not learn MAC addresses. That is, packets in VLAN

    100 were broadcasted to downstream devices.

    After asking the ofce personnel about services

    running, engineers knew that that there were a lot

    of double-tagged PPPOE services that were trans-

    parently transmitted.

    According to the plan, users were identied by

    inner tags and areas were identied by outer tags.

    Therefore, PPPoE service on ZXR10 3952 was

    only allocated with one outer tag vlan 100,

    and all ports were in this vlan.

    From above information, downstream

    PPPOE trafcs were broadcasted in VLAN

    100. Since the uplink port was 1000M and

    the downstream traffics were great, but

    customer port was 100M, downstream

    broadcast traffics were congested. This

    made internet surng slow.

    Solution

    Engineers set the outer tag VLAN id

    to native VLAN id on customer port. Theproblem was solved.

    Figure 1. Network Topology

    Key words: ACL, ping, protocol protection

    Operational Failure through ACLOperational Failure through ACL Zhang Fan / ZTE Corporation

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    18/32

    Maintenance Experience16

    April 2009 Issue 160

    Malfunction Analysis

    Engineers checked configuration of

    ZXR10 3928 switch, as shown below.

    acl extend number 101

    rule 1 deny icmp 10.40.184.0 0.0.3.255

    any

    rule 2 permit ip any any

    !

    int fei_1/1

    protpcol-protect mode icmp disable

    switchport access vlan 1

    ip access-group 101 0 in

    The command to apply ACL is shown

    below:

    ip access-group in

    In this command, parameter is required. The value is 0 or 1.

    0 indicates that protocol protection is en-

    abled and 1 indicates protocol protection

    is disabled. Protocol protection is enabledby default on interface, that is, the default

    value of is 0.

    After protocol protection function was

    enabled, switch improved priority of ICMP

    packets through a set of special rules.

    These rules were placed ahead of ACL.

    ICMP was in protocol protection range.

    Protocol protected packet had a higher pri-

    ority than ACL. As the value of parameter

    on ZXR10 3928 switch was 0 by

    default, the command of disabling ICMP became

    invalid. As a result, PC could still ping to ZXR10

    3928 switch successfully.

    Solution

    Engineers modied the conguration of ZXR10

    3928 switch, as shown below.

    acl extend number 101

    rule 1 deny icmp 10.40.184.0 0.0.3.255 any

    rule 2 permit ip any any

    !int fei_1/1

    protpcol-protect mode icmp disable

    switchport access vlan 1

    ip access-group 101 1 in //Set the value of pa-

    rameter profile-number to 1, that is, protocol-

    protect is disabled

    Experience Summary

    For downlink interface where SVLAN is en-

    abled, the value of parameter

    must be 1. When protocol protection is enabled,

    the value of parameter must be 0.

    When a switch is used as L2 device, then value

    of parameter is allowed to be 1.

    However, in this situation, some control packets

    will fail to be received on the interface and some

    protocol calculations will be wrong. Therefore, set

    the value of parameter to 0.

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    19/32

    Data Products

    www.zte.com.cn

    17

    Network Topology

    DSLAM and switches are down-linked to 3952.

    SVLAN is congured on 3952. Transparent trans-

    mission is congured on T64G. Leased-line users,NM and other services are terminated on T64E.

    PPPOE dial-in users are terminated on BAS. Net-

    work topology is shown in Figure 1.

    Surng Internet in MAN Ye Wei / ZTE Corporation

    some packets were lost. At this peak time

    devices ran normally, and other operation-

    al functions of the devices was normal.

    Malfunction Analysis

    To nd out the problem, engineers took

    the following steps.

    1. Engineers viewed system CPU

    utilization when the speed of surfing in-

    ternet was slow to make sure whether

    CPU utilization was too high to influence

    running of system. The result was shown

    below.

    Figure 1. Network Topology

    ZXR10#show processor

    M: Master processor

    S: Slave processor

    Peak CPU: CPU peak utility measured in 2 minutes

    PhyMem: Physical memory (megabyte)

    Panel CPU(5s) CPU(30s) CPU(2m) Peak CPU PhyMem Buffer Memory

    MP(M) 1 20% 19% 18% 40% 256 0% 35.902%

    The above information showed that the

    CPU was normal.

    2. Engineers viewed trafcs on inter-

    face. Traffics on port may also influence

    the speed of surng internet. If the trafcs

    were too large, congestion would occur,

    and then the speed of surfing internet

    could also be slowed down. Interface traf-

    c information is shown below.

    The planning of VLAN is as follows:

    Leased line: 3001-3500

    Network management system: 99

    The range of outer vlan id for PPPOE dial-in

    user: 100

    The range of inner vlan id for PPPOE dial-in

    user: for DSLAMs, 100 vlans are allocated

    to each device with id range to be 101-500;

    for switches, 40 vlans are allocated to each

    device with id range to be 501-2500.

    Malfunction Situation

    The speed of surng internet at peak hours was

    slow. Delay in sending ping packet was high, and

    Key words: QinQ, VLAN, uplink port, customer port

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    20/32

    Maintenance Experience18

    April 2009 Issue 160

    ZXR10#show interface fei_1/1

    fei_1/1 is up, line protocol is up

    Description is noneKeepalive set:10 sec

    The port is electric

    Duplex full

    Mdi type:auto

    VLAN mode is access, pvid 4094 BW

    100000 Kbits

    Last clearing of "show interface" coun-

    ters never

    120 seconds input rate: 3403245 Bps,

    3117 pps

    120 seconds output rate: 1122389 Bps,

    11912 pps

    Interface peak rate:

    input 8120382 Bps, output 12420382

    Bps

    Interface utilization: input 29%, output

    90%

    Input:

    P a c k e t s : 1 9 0 2 8 1 7 4 6 1 2 B y t e s :

    24122478262892

    Unicasts: 18709469101 Multicasts:19281980

    Broadcasts: 299188371 Undersize:

    230911

    Oversize: 3247 CRC-ERROR: 9

    Dropped: 1091 Fragments: 0

    Jabber: 1002 MacRxErr: 0

    Output:

    Pack e t s : 142123550101 By t e s :

    182329420262394

    Unicasts: 56909126342 Multicasts:

    729262387

    Broadcasts: 84485161372 Collision: 0

    LateCollision: 0

    Total:

    64B: 772661029 65-127B: 803872612

    128-255B: 1292984228 256-511B:

    2374859862

    512-1023B: 63467072821 1024-1518B:

    92427412536

    The above information showed that trafcs on

    customer port in outgoing direction were large and

    it caused congestion. Engineers viewed traffic in-

    formation on other interfaces. They found that traf-

    fics in outgoing direction of other interfaces were

    also large.

    3. Engineers viewed traffics on uplink inter-

    face, as shown below.

    ZXR10#show interface gei_2/1

    gei_2/1 is up, line protocol is up

    Description is none

    Keepalive set:10 sec

    The port is electric

    Duplex full

    Mdi type:auto

    VLAN mode is access, pvid 4094 BW 1000000 Kbits

    Last clearing of "show interface" counters never

    120 seconds input rate : 29123012 Bps, 29081 pps

    120 seconds output rate: 14133829 Bps, 13909 pps

    Interface peak rate :

    input : 50234251 Bps, output 5292182 Bps

    Interface utilization: input 28%, output 19%

    The above information showed that trafcs on

    uplink port were normal.

    4. Engineers viewed alarm information. No

    abnormal alarm was presented and no MAC oat-

    ing alarm occurred. Therefore, it was not loop that

    caused broadcast storm.

    5. Engineers analyzed configuration on the

    device. QinQ conguration is shown below.

    ZXR10(cong)#show vlan qinqSession Customer Uplink In_Vlan Ovlan Helpvlan----------------------------------------------------1 fei_1/1 gei_2/1 101-200 100

    2 fei_1/2 gei_2/1 201-300 100

    3 fei_1/3 gei_2/1 301-400 100

    4 fei_1/4 gei_2/1 401-500 100

    5 fei_1/5 gei_2/1 501-540 100

    6 fei_1/6 gei_2/1 541-580 100

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    21/32

    Data Products

    www.zte.com.cn

    19

    Port conguration is shown below.

    ZXR10(cong)#show run interface fei_1/1

    description TO-DS01

    no negotiation auto

    switchport mode hybrid

    switchport hybrid native vlan 4094

    switchport hybrid vlan 99 tag

    switchport hybrid vlan 100 untag

    switchport hybrid vlan 3001-3010 tag

    switchport qinq customer

    ZXR10(cong)#show run interface fei_1/2

    description TO-DS02

    no negotiation auto

    switchport mode hybrid

    switchport hybrid native vlan 4094

    switchport hybrid vlan 99 tag

    switchport hybrid vlan 100 untag

    switchport hybrid vlan 3011-3020 tag

    switchport qinq customer

    ZXR10(cong)#show run interface fei_2/1

    description to-T64G

    no negotiation auto

    hybrid-attribute ber

    switchport mode hybrid

    switchport hybrid native vlan 1

    switchport hybrid vlan 99 tag

    switchport hybrid vlan 101-150 tag

    switchport hybrid vlan 3001-3500 tag

    switchport hybrid vlan 501-2500 tag

    switchport hybrid vlan 4094 untag

    switchport qinq uplink

    With the above information results,

    engineers found that native VLAN on each

    port was Helpervlan 4094. Double-tagged

    services were implemented through VLAN

    QinQ. Therefore, MAC learning was in

    Helpervlan 4094, and the VLAN 100 would

    not learn MAC addresses. That is, packets

    in VLAN 100 were broadcasted to down-

    stream devices.

    After asking the ofce personnel about

    services running, engineers knew that that

    there were a lot of double-tagged PPPOE

    services that were transparently transmit-

    ted.

    According to the plan, users were

    identified by inner tags and areas were

    identied by outer tags. Therefore, PPPoE

    service on ZXR10 3952 was only allocated

    with one outer tag vlan 100, and all ports

    were in this vlan.

    From above information, downstream

    PPPOE trafcs were broadcasted in VLAN

    100. Since the uplink port was 1000M and

    the downstream traffics were great, but

    customer port was 100M, downstream

    broadcast traffics were congested. This

    made internet surng slow.

    Solution

    Engineers set the outer tag VLAN id

    to native VLAN id on customer port. The

    problem was solved.

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    22/32

    Maintenance Experience20

    April 2009 Issue 160

    Malfunction Situation

    As shown in Figure 1, ACL was applied on interface Fei_1/1

    of ZXR10 3928 switch to forbid PC to ping to 3928. The congu -

    ration failed but still PC could ping 3928 successfully.

    proved priority of ICMP packets through a set of

    special rules. These rules were placed ahead of

    ACL. ICMP was in protocol protection range. Proto-

    col protected packet had a higher priority than ACL.

    As the value of parameter on

    ZXR10 3928 switch was 0 by default, the command

    of disabling ICMP became invalid. As a result, PC

    could still ping to ZXR10 3928 switch successfully.

    Solution

    Engineers modied the conguration of ZXR10

    3928 switch, as shown below.

    acl extend number 101

    rule 1 deny icmp 10.40.184.0 0.0.3.255 any

    rule 2 permit ip any any!

    int fei_1/1

    protpcol-protect mode icmp disable

    switchport access vlan 1

    ip access-group 101 1 in //Set the value of pa-

    rameter prole-number to 1, that is, protocol-

    protect is disabled

    Experience Summary

    For downlink interface where SVLAN is en-

    abled, the value of parameter

    must be 1. When protocol protection is enabled,

    the value of parameter must be 0.

    When a switch is used as L2 device, then value

    of parameter is allowed to be 1.

    However, in this situation, some control packets

    will fail to be received on the interface and some

    protocol calculations will be wrong. Therefore, set

    the value of parameter to 0.

    Operational Failure through ACL Zhang Fan / ZTE Corporation

    Figure 1. Network Topology

    Malfunction Analysis

    Engineers checked configuration of ZXR10 3928 switch, as

    shown below.

    acl extend number 101

    rule 1 deny icmp 10.40.184.0 0.0.3.255 any

    rule 2 permit ip any any

    !

    int fei_1/1

    protpcol-protect mode icmp disable

    switchport access vlan 1ip access-group 101 0 in

    The command to apply ACL is shown below:

    ip access-group in

    In this command, parameter is required. The

    value is 0 or 1. 0 indicates that protocol protection is enabled and

    1 indicates protocol protection is disabled. Protocol protection is

    enabled by default on interface, that is, the default value of is 0.

    After protocol protection function was enabled, switch im-

    Key words: ACL, ping, protocol protection

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    23/32

    Data Products

    www.zte.com.cn

    21

    Network Topology

    IBGP protocol runs between T1200-1 and

    T1200-2. EBGP runs between T1200-1 and

    T128-1. EBGP runs between T1200-2 and T128-2.

    IBGP protocol runs between T128-1 and T128-2.

    IBGP and OSPF run between 128 and T64.

    The network topology is shown in Figure 1.

    ip address 10.0.0.5 255.255.255.252

    router bgp 4809

    neighbor 3.3.3.3 remote-as 65514 //

    Designated EBGP neighbor

    neighbor 3.3.3.3 activate

    neighbor 3.3.3.3 update-source loop-

    back1

    neighbor 3.3.3.3 ebgp-multihop

    neighbor 10.0.0.2 remote-as 4809 //

    Designated IBGP neighbor

    neighbor 10.0.0.2 activate

    Conguration of T1200-2:

    interface loopback1

    ip address 2.2.2.2 255.255.255.255

    interface pos48_1/1

    ip address 10.0.0.2 255.255.255.252

    interface pos48_2/1

    ip address 10.0.0.9 255.255.255.252

    router bgp 4809neighbor 4.4.4.4 remote-as 65514 //

    Designated EBGP neighbor

    neighbor 4.4.4.4 activate

    neighbor 4.4.4.4 update-source loop-

    back1

    neighbor 4.4.4.4 ebgp-multihop

    neighbor 10.0.0.1 remote-as 4809 //

    Designated IBGP neighbor

    neighbor 10.0.0.1 activate

    Figure 1. Network Topology

    Malfunction SituationDevice congurations are shown below.

    Conguration of T1200-1:

    interface loopback1

    ip address 1.1.1.1 255.255.255.255

    interface pos48_1/1

    ip address 10.0.0.1 255.255.255.252

    interface pos48_2/1

    Key words: EBGP, neighbor

    Abnormal EBGP NeighborhoodEstablishmentAbnormal EBGP NeighborhoodEstablishmentXia Ying / ZTE Corporation

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    24/32

    Maintenance Experience22

    April 2009 Issue 160

    Conguration of T128-1:

    interface loopback1

    ip address 3.3.3.3 255.255.255.255

    interface pos48_1/1

    ip address 10.0.0.6 255.255.255.252

    interface gei_2/1

    ip address 10.10.10.1 255.255.255.252

    interface gei_3/1

    ip address 10.10.10.5 255.255.255.252

    router ospf 100 // Starting OSPF process

    network 3.3.3.3 0.0.0.0 area 0.0.0.0

    network 10.10.10.0 0.0.0.3 area 0.0.0.0

    network 10.10.10.4 0.0.0.3 area 0.0.0.0

    router bgp 65514

    neighbor 1.1.1.1 remote-as 4809 // Des-

    ignated EBGP neighbor

    neighbor 1.1.1.1 activate

    neighbor 1.1.1.1 update-source loopback1

    neighbor 1.1.1.1 ebgp-multihop

    neighbor 4.4.4.4 remote-as 65514 //

    Designated IBGP neighbor

    neighbor 4.4.4.4 activate

    neighbor 4.4.4.4 update-source loopback1

    neighbor 5.5.5.5 remote-as 65514

    neighbor 5.5.5.5 activate

    neighbor 5.5.5.5 update-source loopback1

    Conguration of T128-2:

    interface loopback1

    ip address 4.4.4.4 255.255.255.255

    interface pos48_1/1ip address 10.0.0.10 255.255.255.252

    interface gei_2/1

    ip address 10.10.10.2 255.255.255.252

    interface gei_3/1

    ip address 10.10.10.9 255.255.255.252

    router ospf 100 //Starting OSPF Pro-

    cess

    network 4.4.4.4 0.0.0.0 area 0.0.0.0

    network 10.10.10.0 0.0.0.3 area 0.0.0.0

    network 10.10.10.8 0.0.0.3 area 0.0.0.0

    router bgp 65514

    neighbor 2.2.2.2 remote-as 4809 // Designated

    EBGP neighbor

    neighbor 2.2.2.2 activate

    neighbor 2.2.2.2 update-source loopback1

    neighbor 2.2.2.2 ebgp-multihop

    neighbor 3.3.3.3 remote-as 65514 // Designated

    IBGP neighbor

    neighbor 3.3.3.3 activate

    neighbor 3.3.3.3 update-source loopback1

    neighbor 6.6.6.6 remote-as 65514

    neighbor 6.6.6.6 activate

    neighbor 6.6.6.6 update-source loopback1

    Conguration of T64E-1:

    interface loopback1

    ip address 5.5.5.5 255.255.255.255

    interface gei_1/1

    ip address 10.10.10.6 255.255.255.252

    router ospf 100 //Starting OSPF Process

    network 5.5.5.5 0.0.0.0 area 0.0.0.0

    network 10.10.10.4 0.0.0.3 area 0.0.0.0

    router bgp 65514

    neighbor 3.3.3.3 remote-as 65514 // Designated

    IBGP neighbor

    neighbor 3.3.3.3 activate

    neighbor 3.3.3.3 update-source loopback1

    EBGP connection can not be established be-

    tween T128-1 and T1200-1.

    Malfunction Analysis

    To nd out the problem, engineers took the fol-

    lowing steps.

    1. Engineers viewed BGP neighbor informa-

    tion on T128-1, as shown below.

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    25/32

    Data Products

    www.zte.com.cn

    23

    T128-1#show ip bgp summary

    Neighbor Ver As MsgRcvd MsgSend Up/Down(s) State

    1.1.1.1 4 4809 0 0 0h Connect

    4.4.4.4 4 65514 255152 255339 13w1d2h Estab-

    lished

    5.5.5.5 4 65514 27912 273892 1w1d20h Established

    2. Engineers pinged to the neighbor with

    which the connection was established normally on

    T128-1, as shown below.

    T128-1#ping 4.4.4.4

    sending 5,100-byte ICMP echos to 4.4.4.4,timeout is

    2 seconds.

    !!!!!

    Success rate is 100 percent(5/5),round-trip

    min/avg/max=0/8/20ms

    3. Engineers pinged to the neighbor with

    which the connection was established abnormally

    on T128-1, as shown below.

    T128-1#ping 1.1.1.1

    sending 5,100-byte ICMP echos to 1.1.1.1,timeout is

    2 seconds.

    .....

    Success rate is 0 percent(0/5)

    4. Engineers viewed network segment route

    on T128-1, as shown below.

    show ip route 1.1.1.1

    IPv4 Routing Table:

    Dest Mask Gw Interface Owner pri metric

    BGP route protocol sent protocol packets based

    on TCP protocol 179. It could be determined that

    the links were established unsuccessfully, because

    IP router was not reachable. It was necessary to

    add static routes between T128 and T1200.

    Solution

    Engineers added static routes on

    T1200-1 and T128-1.The static route conguration added to

    T1200-1 is shown below.

    T1200_1(config)#ip route 3.3.3.3

    255.255.255.255 10.0.0.6

    The static route conguration added to

    T128-1 is shown below.

    T128_1(config)#ip route 1.1.1.1255.255.255.255 10.0.0.5

    Engineers viewed neighbor information

    on T128-1, as shown below.

    In the same way, engineers added

    static routes on T128-2 and T1200-2.

    Therefore, the neighbor relationship can

    be established normally.

    Experience Summary

    To configure EBGP interconnection

    and establish neighborhood by loopback

    address, the static route conguration can

    not be neglected.

    Additionally, the command neighbor

    ebgp-multihop is necessary

    to establish EBGP with loopback address-

    es.

    T128-1#show ip bgp summary

    Neighbor Ver As MsgRcvd MsgSend Up/Down(s) State

    1.1.1.1 4 4809 2230 2221 1h Established

    4.4.4.4 4 65514 264329 265436 13w1d3h Established

    5.5.5.5 4 65514 299126 283898 1w1d21h Established

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    26/32

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    27/32

    Data Products

    www.zte.com.cn

    25

    CPU 5s of master MP is 23%, which was in normal range

    (in case CPU 5s exceeds 40%, it indicates there is some-

    thing wrong. 30% is normal when there are large service

    trafcs).

    By analyzing CPU, the previous judgments were wrong.

    It was necessary to nd out the problem from other aspects.

    2. It may be the problem of T160G-1 itself, for example,

    CPU of the main board was high or corresponding line inter-

    face card CPU was high, which led to that message queue

    was completely occupied by other packets transmitted to

    CPU and therefore telnet packets were dropped.

    Engineers executed command show processor on

    T160G-1 to view CPU utilizations of the main board and line

    interface cards, as shown below.

    telned to T64G through T160G-2. The response speed

    was normal. Engineers checked CPU of line interface

    card 1 on T160G-2, it was normal. It could be assumed

    that the fault was related to high CPU utilization of line

    interface card 1 on T160G-1.

    3. The reason for line interface card 1 CPU be-

    ing high was that there were large numbers of packets

    being up-sent to line interface card CPU. They may be

    protocol packets or ordinary packets. When engineers

    executed command show logging alarm, it was found

    that there was no alarm for receiving a large number

    of protocol packets. Therefore, the packets may not be

    protocol packets. It was assumed that it was service

    packets that ooded CPU.

    Engineers executed command capture npc 1 read-

    speed 20 on T160G-1 to capture packets to line card 1.

    The result was shown below.

    T160G-1#show processor

    M: Master processor

    S: Slave processor

    Peak CPU: CPU peak utility measured in 2 minutes

    PhyMem: Physical memory (megabyte)

    Panel CPU(5s) CPU(30s) CPU(2m) Peak CPU PhyMem Memory

    MP(M)1 37% 35% 36% 43% 512 38.164%

    MP(S)2 8% 8% 8% 12% 512 19.578%

    NP(M)1 37% 37% 38% 39% 256 36.105%

    NP(M)2 13% 12% 13% 17% 256 36.105%

    NP(M)3 15% 15% 16% 19% 128 54.055%

    NP(M)4 14% 15% 15% 15% 128 54.055%

    NP(M)5 14% 15% 15% 19% 128 54.055%

    NP(M)6 23% 23% 23% 27% 128 54.056%

    NP(M)7 14% 13% 13% 14% 128 50.971%

    CPU of master main board was fairly high and CPU uti-

    lization of line interface card 1 was particularly higher thanthose of other line interface cards.

    All edge nodes T64G were connected to line interface

    card 1 of T160G-1, except for T160G-2 (connected to line in-

    terface cards 3 and 4). If CPU utilization of line interface card

    1 was too high, the peed of accessing all T64G switches (ex-

    cept for T160G-2) would be slow.

    Engineers validated this assumption, it was correct. To

    perform further validation, engineers connected all edge

    nodes T64G to line interface card 1 of T160G-2, and then

    T160G-1(cong)#capture npc 1 readspeed 20

    IP Packet on NPC: 1

    DST_IP SRC_IP ovid ivid TTL PRO DIR Port

    10.0.9.123 10.107.25.122 9 NULL 61 6 RX 4

    233.18.204.166 124.108.15.105 100 NULL 7 17 RX 1210.0.9.123 10.113.35.122 9 NULL 61 6 RX 2

    10.0.9.123 10.137.26.69 9 NULL 61 6 RX 1

    10.0.9.123 10.133.0.122 9 NULL 61 6 RX 1

    10.0.9.123 10.119.45.123 9 NULL 61 6 RX 2

    233.20.204.4 124.108.15.100 100 NULL 7 17 RX 12

    233.20.204.4 124.108.15.100 100 NULL 7 17 RX 12

    10.0.9.123 10.146.22.61 9 NULL 61 6 RX 6

    10.0.9.123 10.124.122.77 9 NULL 61 6 RX 5

    233.20.204.4 124.108.15.100 100 NULL 7 17 RX 12

    233.20.204.4 124.108.15.100 100 NULL 7 17 RX 12IP Packet on NPC: 1

    PDST_IP SRC_IP ovid ivid TTL PRO DIR Port

    10.0.9.123 10.115.5.123 9 NULL 61 6 RX 2

    233.20.204.17 124.108.15.100 100 NULL 7 17 RX 12

    IP Packet on NPC: 1

    DST_IP SRC_IP ovid ivid TTL PRO DIR Port

    10.0.9.123 10.129.140.120 9 NULL 61 6 RX 1

    10.0.9.123 10.113.36.110 9 NULL 61 6 RX 2

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    28/32

    Maintenance Experience26

    April 2009 Issue 160

    is made clear, it can be known that which line card

    corresponds to which slot uniquely.

    In usual cases, there could not be many multicast ser-

    vice packets up-sent to line interface card CPU. Therefore, it

    was assumed that there was something wrong with multicast

    routing table.

    4. According to the above analysis result, engineers

    executed command show ip mroute to view multicast routing

    table. Group 233.18.204.166 was one of the multicast group

    addresses of CPU captured packets. Take it for example

    here for analysis.

    T 1 6 0 G - 1 ( c o n f i g ) # s h o w i p m r o u t e g r o u p

    223.18.204.166

    IP Multicast Routing Table

    Flags:D-Dense,S-Sparse,C-Connected,L-Local,P-Pruned,

    R-RP-bit set,F-Register ag,T-SPT-bit set,J-Join SPT,

    M-MSDP created entry,N-No Used,U-Up Send,

    A-Advertised via MSDP,X-Proxy Join Timer Running,

    *-Assert ag

    Statistic:Receive packet count/Send packet count

    Timers:Uptime/Expires

    Interface state:Interface,Next-Hop or VCD,State/Mode

    (*,233.18.204.166),1d1h/00:03:34,RP 124.108.8.3,

    150295/150295,ags:SC

    Incoming interface: vlan100, RPF nbr 10.0.100.1

    Outgoing interface list:

    vlan40, Forward/Sparse, 1d1h/00:03:29 C

    By execut ing command show ip mroute group

    233.18.204.166 repeatedly, It was found that only (*, g)

    entry was in this multicast table, and there was no (s,

    g) entry. Packet sending/receiving count of (*,g) entry

    (150295/150295) increased continuously. Multicast data ow

    were forwarded according to (*, g) entry and packets for-

    warded according to (*, g) entry were be up-sent to CPU for

    processing, which led to high CPU.

    Note: Packets forwarded according to (s,g) entry are pro-

    cessed by hardware directly.

    5. Engineers continued to analyze the reason why en-

    try (s, g) was unavailable in multicast routing table.

    10.0.9.123 10.119.97.39 9 NULL 61 6 RX 2

    233.20.204.32 124.108.15.102 100 NULL 7 17 RX 12

    233.20.204.32 124.108.15.102 100 NULL 7 17 RX 12233.20.204.32 124.108.15.102 100 NULL 7 17 RX 12

    233.20.204.32 124.108.15.102 100 NULL 7 17 RX 12

    233.20.204.32 124.108.15.102 100 NULL 7 17 RX 12

    10.0.9.123 10.115.66.108 9 NULL 61 6 RX 2

    233.20.204.4 124.108.15.100 100 NULL 7 17 RX 12

    10.0.9.123 10.127.3.12 9 NULL 61 6 RX 4

    233.20.204.4 124.108.15.100 100 NULL 7 17 RX 12

    Engineers analyzed the result of packet capture (take

    one packet for example), as shown below.

    IP Packet on NPC: 1

    DST_IP SRC_IP ovid ivid TTL PRO DIR Port

    233.20.204.17 124.108.15.100 100 NULL 7 17 RX 12

    The following parameters were concerned.

    DST_IP, SRC_IP: Destination IP and source IP

    of a packet; all packets captured by command

    capture must be up-sent to line card CPU.

    Large number of multicast service packets (withdestination address beginning with 233) and a

    few unicast packets (with destination address to

    be 10.0.9.123) are found in CPU packet capture

    on slot 1.

    Ovid: Outer VLAN tag of the packet. It can be

    seen that it is xed that all multicast packets are

    up-sent to CPU through vlan100 and all unicast

    packets are sent to CPU through vlan9.

    TTL: TTL value of the packet. It is normal as long

    as the value is not 1.

    DIR: Direction of the packet, in receiving direction

    or sending direction. For receiving direction, it

    is RX, indicating the packet is up-sent to CPU

    and for sending direction, it is TX, indicating the

    packet is sent out from CPU

    Port: The physical interface to receive (send)

    a packet. As slot number has been specified

    in command, so as long the physical interface

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    29/32

    Data Products

    www.zte.com.cn

    27

    In normal cases, entry (s,g) could generate as

    long as multicast data ow was available and DR

    knew IP address of multicast source and RPT was

    switched to SPT. If (s,g) entry faied to be gener-

    ated, users could execute command show ip rpf to

    view whether RPF check is passed.

    When an interface on the switch receives multi-

    cast packet sent from a multicast source. if the path

    from switch to this multicast source actually passes

    through this interface according to the routing table

    of this switch, RPF check is passed.

    Engineers continued to analyze the result of

    CPU packet capture, as shown below.

    T160G-1#show ip rpf 124.108.15.105

    RPF information:

    RPF interface vlan501

    RPF neighbor 61.154.120.201 (isnt neighbor)

    RPF metric preference 1 RPF metric value 0

    RPF type : unicast

    Engineers analyzed the result of reverse path

    check. Outgoing interface to multicast source

    124.108.15.105 was 61.154.120.201 (line inter-

    face card 7, vlan 501, default route); with CPU

    packet capture it was found that packets whose

    multicast group address was 233.18.204.166 were

    forwarded from interface 12 of line interface card 1.

    Therefore, RPF check is not passed and entry (s,g)

    could not be generated.

    6. With the above analysis, there were two

    ways to decrease CPU utilization of line interface

    card.i. Configure ACL to filter these multicast

    packets.

    ii. Congure a static route to enable the route

    to 124.108.15.105 pass through interface 12 of line

    card 1 and thus RPF check is passed.

    Since the group 233.18.204.166 was used for

    forwarding multicast service, static route was con-

    gured here so that RPF check could pass.

    Conguration of static route was shown below.

    ip route 124.108.15.0 255.255.255.0

    10.0.100.1

    After static route was congured, engi-

    neers performed RPF check. The informa-

    tion was shown below.

    T160G-1#show ip rpf 124.108.15.105

    RPF information:

    RPF interface vlan100 pimsm

    RPF neighbor 10.0.100.1 (is neighbor)

    RPF metric preference 1

    RPF metric value 0

    RPF type : unicast

    According to the RPF check, it was

    found that the interface belonged to

    vlan100, where there was only one inter-

    face gei_1/12 and it was neighbor. RPF

    check was passed.

    By execut ing command show ip

    mroute, it was found that (s,g) entry was

    generated and data ow could be forward-

    ed according to (s, g) entry rather than ac-

    cording to (*.g).

    T160G-1#show ip mroute group

    233.18.204.166

    IP Multicast Routing Table

    F l a g s : D - D e n s e , S - S p a r s e , C -

    Connected,L-Local,P-Pruned,

    R-RP-bit set,F-Register flag,T-SPT-bit

    set,J-Join SPT,

    M-MSDP created entry,N-No Used,U-

    Up Send,

    A-Advertised via MSDP,X-Proxy Join

    Timer Running,

    *-Assert ag

    Statistic:Receive packet count/Send

    packet count

    Timers:Uptime/Expires

    Interface state:Interface,Next-Hop or

    VCD,State/Mode

  • 8/2/2019 Maintenance Experience Issue160(Data Products)

    30/32

    Maintenance Experience28

    April 2009 Issue 160

    (*, 233.18.204.166), 1d2h/00:02:48,

    RP 124.108.8.3,

    150385/150385, ags: SCIncoming interface: vlan100, RPF nbr

    10.0.100.1

    Outgoing interface list:

    v l a n 4 0 , F o r w a r d / S p a r s e ,

    1d2h/00:02:43 C

    (124.108.15.105, 233.18.204.166),

    00:44:39/00:02:48 , 6340/6340 ,

    ags: CJT

    Incoming interface: vlan100, RPF nbr

    10.0.100.1

    Outgoing interface list:

    v l a n 4 0 , F o r w a r d / S p a r s e ,

    00:44:39/00:02:43 C

    By executing command show ip mroute

    group repeatedly to compare packet send-

    ing/receiving counts, it was verified that

    data ow were forwarded according to (s,g)

    entry rather than according to (*.g). Engineers ex-

    ecuted command show processor to view CPU uti-

    lization of line interface card and it was found that it

    increased rather than decreases. It was normal for

    T160G-1 to telnet the other T64Gs connected to it.

    Experience Summary

    In normal cases, as for each group, there were

    two entries available in multicast routing table, (s,g)

    and (*,g). Both are indispensable. If either of the

    two entries does not exist or it is abnormal, it is

    necessary to analyze the reason.

    Packets forwarded according to (s,g) areprocessed by hardware and packets forwarded

    according to (*,g) are processed by software. In

    normal cases, when device receives multicast data

    ow for the rst time, the device forwards it accord-

    ing to (*,g) and it will implement SPT changeover

    immediately to generate (s,g) entry, and then for-

    ward the multicast data ow by hardware.