Main Line Flow Valve Jurisdic - Transportation · Main Line Unloading Rack Oil Storage Tank...
Transcript of Main Line Flow Valve Jurisdic - Transportation · Main Line Unloading Rack Oil Storage Tank...
Flow Valve
Pump Meter
Breakout Tank
M
Main Line
Fenced
M
Jurisdic on
PHMSA
Tank Mixing system
Surge Tank (Breakout)
Relief
To vacuum truck
Flow Valve
Pump Meter
Storage Tank
M
Main Line
Fenced
Storage Tank
Loading Area
Jurisdic on
PHMSA Not Jurisdic onal
M
If meter is used in conjunc on with Leak detec on system; jurisdic on ends at Valve #3; if not, it reverts upstream to Valve #1 and #2.
3
2
1
Pig Re
ceiver
Flow Valve
Pump Meter M
Main Line
Fenced
Storage Tank
Processing
Plant
If meter is used in conjunc on with Leak detec on system; jurisdic on ends at Valve #2; if not, it reverts up‐stream to Valve #1.
M M
Jurisdic on
PHMSA Not
Jurisdic onal
1
2 Outlet of Facility: PHMSA jurisdic‐on extends to
the pressure influ‐encing device which effects the main pipeline pressure.
Flow Valve
Pump Meter M
Main Line
Fenced
Breakout Tank
Unloading Rack
M M
Breakout Tank
M
Loading Rack M M
M
Jurisdic on
PHMSA Not
Jurisdic onal
Flow Valve
Pump Meter M
Main Line
Fenced
Breakout Tank
M M
Breakout Tank
Loading Rack
Jurisdic on
PHMSA Not
Jurisdic onal
Flow Valve
Pump Meter M
Main Line
Jurisdic on
PHMSA Not
Jurisdic onal
If meter is used in conjunc on with Leak detec on system; jurisdic on ends at Valve #2; if not, it reverts up‐stream to Valve #1.
1
Fence
Storage Tank
M (Un)Loading Rack
Storage Tank
Storage Tank
Storage Tank
Storage Tank
Storage Tank
M
M 2
Flow Valve
Pump Meter M
Main Line
Fence
Breakout Tank
M (Un)Loading Rack
Storage Tank
Storage Tank
Breakout Tank
Breakout Tank
Breakout Tank
M
M
Jurisdic on
PHMSA Not
Jurisdic onal
Main Line
Unloading Rack
Oil Storage
Tank
Separator
Oil Storage
Tank
Water Storage
Tank
Fence
Gas
Lin
e
LACT Meter
M Unregulated Rural Gathering
Line
Rural Gathering Lines must come from production (not truck or rail), are 6 5/8” to 8 5/8”
in diameter, operate at more than 20 % SMYS, and are within 1/4 mile of a USA
M
USA
Separator
M
M
Production Lines
Fence
Unloading Rail or
Truck Rack Fence
This line is not regulated when the
pipeline is low stress and serves
truck or rail, and is less than one mile
Oil Storage
M
Flow Valve PHMSA Regulated Gathering
Version Date:
Pump Meter Not PHMSA Regulated
Unregulated Gathering
3/1/2015
Note: Rural Gathering system
piping that reaches a pipe diame-
ter > 8 5/8 becomes a fully regu-
lated transmission pipeline. If
piping down stream of a transmis-
sion pipeline decreases in size to 8
5/8 or less, it remains a transmis-
sion pipeline.
Regulated Rural Gathering Line
Fully Regulated Non-Rural Gather-ing Line (city limits)
Flow Valve
Pump Meter M
Main Line
Fenced
Breakout Tank
Refinery
M M
Storage Tank
M Loading Rack
Jurisdiction
PHMSA Not
Jurisdictional
Flow Valve
Pump Meter M
Jurisdic on
Main Line
Tank Dike
Breakout Tank
M M
MTR facility (33 CFR 154.1020) ‐ This seg‐ment up to the first valve inside of a tank dike is under Coast Guard Jurisdic on for the purposes of CWA Sec on 311(i).
Marine
Loading
Dock
PHMSA PHMSA/USCG
Not
Jurisdic onal USCG
Flow Valve
Pump Meter M
Main Line
If meter is used in conjunc on with Leak de-tec on system; jurisdic on ends at Valve #2; if not, it reverts upstream to Valve #1.
Frac ona on Plant M M Loading Rack
Jurisdic on
PHMSA Not
Jurisdic onal
Storage well
Storage well
Storage well
M
2
1
Flow Valve
Pump Meter
Storage Tank
M
Main Line
Fenced
Storage Tank
Un‐Loading Area
Jurisdic on
PHMSA Unregulated
M
Pig Laun
cher
Tank
Tank
Tank
Tank
This line is not regulated when the pipeline is low stress and
serves truck or rail, and is less than one mile long (measured
outside facility grounds).