ELECTROMAGNETIC LOCK INSTALLATION INSTRUCTIONS
250 X 42 X 25 (mm) 190 X38 X 26 (mm) 267 X 66 X 40 (mm)
Model:
SL200S Primary
SL200 Standard
SL200T Ttype
SL200M Mortise
SL220S Primary
SL220 Standard
SL220T Ttype
SL200DS Primary
SL200D Standard
SL200DT Ttype
SL220DS Primary
SL220D Standard
SL200DT Ttype
500 X 42 X 25 (mm) 534 X 66 X 40 (mm)
☆ Primary :No indicator ☆ Standard :Indicator and monitor output include ☆Ttype: :Indicator,monitor output,delay
SL200 Series SL220 Series Notation Power supply DC 12V /DC 24V DC 12V /DC 24V
400mA/12VDC 500mA/12VDC 200mA/24VDC 250mA/24VDC
Door sensor Hall Effect Sensor Operation delay time Application Holding forces 600lbs(250Kg) 1200lbs(500Kg) Operation temperature Warranty Weight 2kg 5kg
35℃ ± 5℃ (Iinside air temperature 30℃) The warranty is 2 years for normal using
Operation current
NO & NC(Only for Standard and Ttype model) 0Sec./3Sec./5Sec./9 Sec. (Only for Ttype model) Outswing door and Inswing door
Electromagnetic Lock Specification:
Accessories: Model type
SL200 SL220 Notations
Sexnut Bolt 1 1 Door spacer 1 1 Screw 4X25mm 6 X Screw 4X15mm 3 1 Screw 5X32mm X 4 Screw 5X25mm X 2 Rubber washer 2 2 Washer 3 3
Allen keys 3mm 1 X Hexgon keys 5mm 1 1 Guide pins 2 2
Type Quantity
3.2mm(1/8") 8mm(5/16")
Magnet(Mini)
3.2mm(1/8" )
Electromagnetic lock accessories diagram :
8 .0 m m ( 5/16 " )
A rm a tu re(M i n i)
6. 4m m x 12 .5 m m (1 /4 " x 1/2" )
6 . 4 m m x 1 2. 5m m (1 /4" x 1/2" )
Body
Alignment sticker
Page 1
time and push button input include
![Page 2: Magnetic Lock Install_Instructions](https://reader037.fdocuments.us/reader037/viewer/2022100415/553277515503469d708b45cf/html5/thumbnails/2.jpg)
Installation instructions :
Place the magnet template on top of door frame and the armature template on top of door leaf according to the above drawings . Try to check if they are on the right position before drilling all the holes.
Ensure the armature is set to the right position and drill a 12 mm hole from sexnut bolt side and drill an 8 mm hole through the door .When hollow door is used , user should drill a 16 mm hole . A door spacer is used to fit in a sexnut bolt. Then,push the sexnut bolt in the drilled hole and tighten it with screw driver . The armature must be loose slightly to compensate the door misalignment , so that the armature face and the magnet face can be closed and make the magnetic force to maximum effect.
Drill an 8mm (5/16”) hole through door
Rubber washer
吸附板 Armature Screw M8
Drill 12 mm (1/2”) Ø X 25mm (1”) from sexnut
Sexnut Bolt
Page 2
When installing magnetic lock user should be sure of the type of door used .Magnetic lock is specifically for the use of outswing door.A bracket is used to install with magnetic door for inswing door.
[Outswing door] [Inswing door] [“L.Z.” Bracket] [Installation ]
[Outswing door]
Fix the mounting plate in the door jamb using supplied selftapping screw.
Mounting plate
( Smooth surface faces up )
Knock guide pins in to fasten the armature [2] [1]
Door leaf
must be loose slightly
Step1 :
Step2 :
Step3 :
Armature
“Z” Bracket
“L” Bracket
Indoor
Door leaf
Door Frame
“L” Bracket
Outdoor
Armature Screw
Rubber washer
![Page 3: Magnetic Lock Install_Instructions](https://reader037.fdocuments.us/reader037/viewer/2022100415/553277515503469d708b45cf/html5/thumbnails/3.jpg)
門框
主體固定板
電磁鎖主體
吸附板
橡皮墊圈
門板
門檔
Step 4: Select the correct voltage and delay time
Step 5 :
Fix the magnet to the mounting (screws for fitting are included in the magnetic body) and ensure the armature close lightly against the magnet when the door is closed to avoid damage to the mating surface unnecessary.
※ Voltage Selection Jumper
+V —V
N. O. COM N. C.
Power Input
Primary Standard
※Monitor output (0.5A) will change to N.O. point when magnetic lock and armature are engaged (Red light of indicator will change to green light )
Page 3
[Inswing door] (Bracket shall be used to install)
Body
Indoor
Outdoor
Power I nput +V —V
※ ( Setting of voltage, please refer to outswing door 『 Step 4 』)
Ttype Autolock Delay Time Settings
Armature
Fix the magnet in the door jamb and fix the armature with the L.Z. bracket in the door leaf. (as follow)
Step 1 :
Door Frame
Blade Stop
Rubber Washer
Armature
Mounting Plate
Body
Door leaf [Installation diagram]
N. O.
N. C.
COM
ON 1 2
0.0 SEC
5.0 SEC
2.5 SEC
9.0 SEC
0 .0sec 2.5 sec
9.0 sec 5 .0sec
1 2
ON
12V 24V
Voltage Select
S2
V+
V
P.S
N.O
COM.
N.C
Power Supply
Ex it Bu tton
Monitor Output
Time Delay Switch
![Page 4: Magnetic Lock Install_Instructions](https://reader037.fdocuments.us/reader037/viewer/2022100415/553277515503469d708b45cf/html5/thumbnails/4.jpg)
Attentions: (1) Regardless the type of door used, the lock must be installed or mounted indoors.
(2) The armature must be loose slightly to compensate the door misalignment.
(3) Door spacer is used to prevent any damage to the hollow door when it is tightened.
(4) EB/SB series of armature brackets are used when installing outswing.
[Installation diagram for bracket and magnetic lock]
Indoor
Outdoor
Pull
[EB200/220]
Page 4
◆ Door is not lightly locked? 1.Check if the voltage is correct2.Check if the setting of voltage is correct3.Check if the magnetic lock and armature are engaged lightly.
◆ Indicator light is unable to show green light when door closed? 1.Check if the armature is mounted to the correct position. 2.Check if the voltage is set correctly. Any dust or rust will affect the operation of the lock.
◆ Maintenance of the magnetic lock? 1.Any dust or rust should be removed regularly. 2.Lubricant should be apply on the magnetic lock to avoid any rust depending on the environment it is installed (such as seaside).
Question & answer
02.8.V10.E
Armature
“Z” Bracket
“L” Bracket
Indoor
Door leaf
Door Frame
“L” Bracket
Outdoor
Armature Screw
Armature plate housing [SB200/220]
Armature plate bracket
To be used with EB or SB bracket
[UB200/220] Glass holder
wooden door
wooden door
glass door