Chapter 3b Macro and Macro Preprocessor-Design of Macro Prepropcessor
Macro ENG
description
Transcript of Macro ENG
Gear pump‘macro system’ series are high melt capacity units and they can be supplied with different pump capacities. The gearpump allows an equal and precise glue application by a control of the glue quantity through the gear speed.
Multifunctional electronic controlThis new development combines the electronic ‘meler’ control that allows a very userfriendly heandling and very effective an intuitive motor control.
Easy AccessThe easy access to all the components of the ‘macro system’ units is a big advantage. It allows a fast access to all internal components of the system (motor, controls etc.) by means of dismountable protection panels and a electronic cabinet mounted on a sliding rail.
ConnectionsThe hose connections of the ‘macro system’ units can be installed at the rear or on one side of the system, depending on the needs of the installation. Two hoses per pump and manifold can be installed with a maximum of four pumps per unit.
TankThe tank consists in three parts: a big hopper, a premelting zone and the main melt zone. Individual temperature control for each zone allows a gentle and carefull melting of the hot-melt. The new ‘macro system’ permits the use of small glue pellets as well as 20 Kg packs of P.U.R. glue. The ‘macro system‘ tank is equipped with a closing valve, in order to interrupt the glue flow between tank and
manifold for easy cleaning and maintenance of the pump, manifold, pressure relief valve and filter. The PUR version comes with a air dryer system, that maintain the tank-air fully dry, and an air-proof tank lid with an air extraction valve.
Motor-pumpThe assembly of motor-gearbox-pump garanties an equal hot-melt supply, which is controlled by the motor rotation speed. A large number of pump sizes (1cc to 30cc) and simple and twin pumps are available.
CompatibilityThe ‘macro system’ can be equipped with Pt100 as well as with Ni120 sensor technologie. Therefore it is compatible with most of the common hot melt systems in the market.
SafetyThe pressure relief valve ensures, that excess pressure situations are avoided in the system. It also allows to maintain a constant system pressure even in intermittent applications.The pneumatic control (optional) allows an easier external system pressure control displaying pressure value on a pressure gauge.
GLU
ING
SO
LUTI
ON
S
serie macro system
Large tank lid to make charging easier
Easy-to-use controls for temperatures
TECHNICAL CHARACTERISTICS
Tank capacity ................................................................. 50, 100 and 200 liters (50 PUR version with air-proof tank lid)Pumping rate (*) ............................................................ 1, 4, 8, 15, 20 and 30 cc/rev single pump 0.6x2, 1.2x2, 2.4x2, 4.8x2 cc/rev double pumpMelting rate (*) .............................................................. a tank per hourNumber of pumps ......................................................... up to 2 pumps (50) up to 4 pumps (100 or 200)Number of hydraulic connections ................................. 2 per pumpNumber of electrical connections ................................ up to 4 outputsMotor power .................................................................. 0.375, 0.55, 0.75, 1.1 kWPump speed ................................................................... 0-100 rpm (10-80 rpm recommended)Temperatures range ...................................................... 40 to 200ºC (230ºC optional)Temperature control ...................................................... RTD ±0,5ºC (±1ºF)Max. working pressure .................................................. 90 bar (1.305 psi)Pressure relief valve ...................................................... pneumatic or mechanicalMax. installation power (at 230 VAC) ............................ 10.750 W (1 single pump/2 outputs) (50) 14.800 W (2 single pumps/4 outputs) (50) 17.050 W (1 single pump/2 outputs) (100) 21.100 W (2 single pumps/4 outputs) (100) 37.240 W (1 single pump/2 outputs) (200) 41.650 W (2 single pumps/4 outputs) (200) External functions ......................................................... Temperaturas ok output Low level output External standby activation Outputs disabled external control ON/ OFF/ Motor Motor speed external controlElectrical requirements ................................................ 3N ~ 400V 50/60 Hz + PEOptions .......................................................................... Low level detector Air dryer system for PUR Input for external auxiliary tank Automatic feeding system* Depending on type of adhesive
DIMENSIONS
Head OfficePol. Los Agustinos, c/G, nave D-43E-31160 Orcoyen - Navarra - SpainPhone: +34 948 351 110Fax: +34 948 351 130email: [email protected]
www.meler.eu
GLUING SOLUTIONS
C 01
1- E
NG -
V051
4 -
MEL
ER re
serv
es th
e rig
ht to
mod
ify th
e co
nten
ts o
f thi
s cat
alog
ue w
ithou
t not
ice.
1600
(50/
100)
16
26 (2
00)
1120
510 (50) 875 (100/200)
1080 (50/100)1440 (200)