The tube drains into this gutter Flushing the M2 Capping Station In the waste compartment above the waste jug there is a gutter that catches waste ink from the capping station pump and ink splatter from the wiper blade. This all drains into the jug. The capping station pump has two tubes that come together to one tube. This tube drains into the gutter.

Transcript of M2 Capping Station flush - ColDesi Capping Station flush.pdfFlushing the M2 Capping Station In the...

Page 1: M2 Capping Station flush - ColDesi Capping Station flush.pdfFlushing the M2 Capping Station In the waste compartment above the waste jug there is a gutter that catches waste ink from

The tube drains into this gutter

Flushing the M2 Capping Station

In the waste compartment above the waste jug there is a gutter that catches waste ink from the capping station pump and ink splatter from the wiper blade. This all drains into the jug.

The capping station pump has two tubes that come together to one tube. This tube drains into the gutter.

Page 2: M2 Capping Station flush - ColDesi Capping Station flush.pdfFlushing the M2 Capping Station In the waste compartment above the waste jug there is a gutter that catches waste ink from

Pull the tube out for access

Connect syringe here

Do not forget to put the tube back int the gutter

The tube has a connector that can connect directly to your syringe. You can apply flushing solution to your capping station and then use the syringe to draw the flush through the capping station.

Repeat it several times to flush and rinse the capping station pad and tubing. This should be preformed once a week to keep the capping station flowing.

Fill with Flushing Solution

Flushing the M2 Capping Station