Page 1: M sata raid_adaptec

USER’S GUIDE

ADAPTEC EMBEDDED SERIAL ATA RAID

Page 2: M sata raid_adaptec

Copyright© 2004 Adaptec, Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written consent of Adaptec, Inc., 691 South Milpitas Blvd., Milpitas, CA 95035.

TrademarksAdaptec, the Adaptec logo, Adaptec Storage Manager, and HostRAID are trademarks of Adaptec, Inc., which may be registered in some jurisdictions.

Windows 2000, Windows Server 2003, and Windows XP are trademarks of Microsoft Corporation in the US and other countries, used under license.

All other trademarks are the property of their respective owners.

ChangesThe material in this document is for information only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, Adaptec, Inc. assumes no liability resulting from errors or omissions in this document, or from the use of the information contained herein.

Adaptec reserves the right to make changes in the product design without reservation and without notification to its users.

DisclaimerIF THIS PRODUCT DIRECTS YOU TO COPY MATERIALS, YOU MUST HAVE PERMISSION FROM THE COPYRIGHT OWNER OF THE MATERIALS TO AVOID VIOLATING THE LAW WHICH COULD RESULT IN DAMAGES OR OTHER REMEDIES.

ii

Page 3: M sata raid_adaptec

Contents

1 Introduction Overview 1-1

What is HostRAID? 1-1Operating System Compatibility 1-2Storage Requirements 1-2Features 1-2Storage Management Software Overview 1-3

2 Installing the Driver Installing the Driver in a New Windows System 2-2Installing the Driver in an Existing Windows System 2-3Installing Red Hat or SuSE Linux 2-3

Installing the Red Hat Driver in a New Linux System 2-3Installing the SuSE Driver in a New Linux System 2-4Installing or Updating the Driver in an Existing Red Hat or SuSE Linux System 2-5

Installing the Netware Driver in a New NetWare System 2-6Installing or updating device drivers after installing NetWare 2-7

Updating the Device Drivers 2-7Installing the Device Drivers 2-7

3 Installing and Starting Adaptec Storage Manager Installing Storage Manager on Windows 3-2Installing Storage Manager on Linux 3-3Installing Storage Manager on NetWare 3-4Starting Storage Manager 3-5Logging into Remote Systems 3-5

iii

Page 4: M sata raid_adaptec

Contents

4 Understanding Adaptec Storage Manager Introduction 4-1

Features 4-1Overview 4-2

Physical Devices View 4-3Logical Devices View 4-3

Changing How Drives are Displayed 4-4Collapsed and Expanded Views 4-4Component Views 4-5

5 Adaptec RAID Configuration Utility Using the Array Configuration Utility 5-2

Managing Arrays 5-2Creating Arrays 5-3Add/Delete Hotspares 5-6Initializing Disk Drives 5-6Rebuilding Arrays 5-7Verifying Drives 5-8

Using the Disk Utilities 5-8

Glossary

Index

iv

Page 5: M sata raid_adaptec

1

IntroductionIn this Chapter...

OverviewAdaptec Embedded Serial ATA RAID with HostRAID® adds RAID functionality to the Serial ATA I/O controller by supporting RAID levels 0, 1, and 10.

What is HostRAID?HostRAID adds entry level RAID support to the Serial ATA I/O controller. With HostRAID, you can add reliable performance and full data protection.

Overview 1-1

Operating System Compatibility 1-2

Storage Requirements 1-2

Features 1-2

Storage Management Software Overview 1-3

1-1

Page 6: M sata raid_adaptec

Introduction

Operating System Compatibility

Note: The HostRAID embedded software product supports the following operating systems. However, depending on the vendor and specific configuration of your system, it is possible that only some of these operating systems are supported. Consult your hardware vendor to clarify operating system support.

■ Microsoft® Windows® 2000, Windows Server® 2003, Windows XP, and IA-32

■ Linux

■ Red Hat Advanced Server 2.1 and 3.0

■ SuSE SLES 8.0 and 8.2

■ SuSE 9.0

■ United Linux 1.0

■ Miracle Linux 2.1

■ Novell NetWare 6.5

Storage RequirementsDevice drivers and storage management software require approximately 20 MB of disk space.

FeaturesAdaptec Embedded Serial ATA RAID supports:

■ RAID levels 0, 1, and 10 using Adaptec’s HostRAID technology.

■ Operating system independent configuration and RAID creation using Adaptec RAID Configuration (ARC).

■ Easy array configuration and status using Adaptec Storage Manager .

Install Adaptec Storage Manager as described in Chapter 3, Installing and Starting Adaptec Storage Manager.

1-2

Page 7: M sata raid_adaptec

Introduction

■ Hot swap rebuild of fault tolerant arrays through the operating system.

■ Event logging and broadcasting, including messaging for alphanumeric pagers.

Storage Management Software OverviewAdaptec Embedded Serial ATA RAID includes the following software tools to manage your storage subsystem:

■ Adaptec Storage Manager—A storage management application that provides you with an easy-to-use graphical interface to manage your storage subsystem. For details, see Chapters 3 and 4.

■ Adaptec RAID Configuration (ARC) Utility—Part of the controller’s built-in BIOS code. You start ARC by pressing Ctrl+A during BIOS startup. For details, see Chapter 5, Adaptec RAID Configuration Utility.

■ Array Configuration Utility (ACU)—A DOS/BIOS application used to create, configure, and manage arrays. For details, see Chapter 5, Adaptec RAID Configuration Utility.

Note: You must have the most recent versions of Adaptec Storage Manager and ARC utility installed to run the Adaptec Embedded SATA RAID drivers.

1-3

Page 8: M sata raid_adaptec

2

Installing the DriverIn this Chapter...

This chapter describes installing the driver and setting up the new array for the drives attached to your controller. Before you get started, you need to select from the following scenarios for installing the controller driver on Windows, Linux, or NetWare systems:

■ Installing the Driver in a New Windows System on page 2-2

■ Installing the Driver in an Existing Windows System on page 2-3

■ Installing Red Hat or SuSE Linux on page 2-3

■ Installing the Netware Driver in a New NetWare System on page 2-6

■ Installing or updating device drivers after installing NetWare on page 2-7

Note: You must have the most recent versions of Adaptec Storage Manager and ARC utility installed to run the Adaptec Embedded SATA RAID drivers.

Installing the Driver in a New Windows System 2-2

Installing the Driver in an Existing Windows System 2-3

Installing Red Hat or SuSE Linux 2-3

Installing the Netware Driver in a New NetWare System 2-6

Installing or updating device drivers after installing NetWare 2-7

2-1

Page 9: M sata raid_adaptec

Installing the Driver

Installing the Driver in a New Windows SystemIn this scenario, you are installing the driver in a new system that has no operating system. To install the driver:

1 Create a driver disk by following the instructions from the Web site or the product CD.

2 Restart the computer.

3 If creating an array, press Ctrl+A when prompted to enter the ARC utility. For instructions on creating an array from the BIOS, see Chapter 5, Adaptec RAID Configuration Utility.

4 When the array is finished building, insert the Windows setup CD and restart the system.

5 Press F6 when prompted to install a third-party driver.

Note: When F6 is active, a prompt appears at the bottom of the screen. Press F6 immediately—you only have 5 seconds. If you miss your chance, restart this Windows installation to complete it correctly. Otherwise, Windows will not recognize your controller.

6 Insert the driver disk you created in Step 1 and wait until prompted to install a driver.

7 Press S to specify that the driver is on the floppy disk, then press Enter.

Windows searches the disk for a suitable driver.

8 When the Adaptec Embedded Serial ATA HostRAID driver is found, press Enter. Follow the remaining on-screen instructions to complete your installation.

2-2

Page 10: M sata raid_adaptec

Installing the Driver

Installing the Driver in an Existing Windows SystemIn this scenario, you are installing a driver in a system that already has a Windows operating system. To install the driver:

1 Create a driver disk by following the instructions from the Web site or the product CD.

2 Start Windows. Windows launches the Found New Hardware Wizard, which searches for the controller driver.

3 Insert the driver disk you created in Step 1, select the floppy disk drive as the source then click Next.

4 If necessary, select the appropriate driver for your operating system.

5 Click Next as needed to complete the controller installation.

6 Remove the driver disk.

7 If prompted, restart the computer.

8 Your installation is complete. If you want to create an array from the BIOS, see Chapter 5, Adaptec RAID Configuration Utility. If you want to create an array from the operating system, see Chapter 4, Understanding Adaptec Storage Manager.

Installing Red Hat or SuSE Linux

Installing the Red Hat Driver in a New Linux SystemIn this scenario, you are installing the driver in a new Red Hat Linux system. To install the driver:

1 Create a driver disk by following the instructions from the Web site or the product CD.

2 Restart the computer.

3 If creating an array, press Ctrl+A when prompted to enter the ARC utility. For instructions on creating an array from the BIOS, see Chapter 5, Adaptec RAID Configuration Utility.

4 When the array is finished building, insert the Red Hat CD Disk 1 in the CD-ROM drive then restart the system.

2-3

Page 11: M sata raid_adaptec

Installing the Driver

5 When the Red Hat Welcome screen appears, type expert or linux dd at the boot prompt.

6 When prompted, insert the driver disk (see Step 1) then select OK.

7 Follow the prompts to set up your preferred environment.

8 If you intend to install other third-party devices, proceed with the installation of those devices. Otherwise, select Done.

9 Continue with the Linux installation according to the Red Hat documentation.

Installing the SuSE Driver in a New Linux SystemIn this scenario, you are installing the driver in a new SuSE Linux system. To install the driver:

1 Create a driver disk by following the instructions from the Web site or the product CD.

2 Restart the computer.

3 If creating an array, press Ctrl+A when prompted to enter the ARC utility. For instructions on creating an array from the BIOS, see Chapter 5, Adaptec RAID Configuration Utility.

4 When the array is finished building, insert the SuSE CD Disk 1 in the CD-ROM drive then restart the system.

5 When the SuSE Installation menu appears, press the F3 key, then select installation option from the Menu then press Enter.

6 When prompted, insert the driver disk you created (see Step 1) then press any key to continue.

7 Follow the prompts to set up your preferred environment.

8 Continue with the Linux installation according to the SuSE documentation.

2-4

Page 12: M sata raid_adaptec

Installing the Driver

Installing or Updating the Driver in an Existing Red Hat or SuSE Linux SystemTo install the driver in an existing Red Hat or SuSE Linux system:

If Driver Files Are On A Web Site

1 Create an rpm diskette for your Linux distribution and version.

2 Insert the rpm diskette into the floppy diskette drive then open up a command shell. From the shell type:

mount /dev/fd0 /mnt/floppy

cd /mnt/floppy

rpm -ivh <rpmfile> (for a new install, or)

rpm -Uvh --force <rpmfile> (for an updated install)

3 Reboot the system to enable the new/updated driver.

If Driver Files Are On The Product CD

1 Insert the driver CD into the CD device and wait for the system to automount the cd, or manually mount it from a shell by typing:

mount /dev/cdrom /mnt/cdrom

2 Then type:

cd /<directory of rpm files>

3 Type:

rpm -ivh <rpmfile> (for a new install, or)

rpm -Uvh --force <rpmfile> (for an updated install)

cd

umount /mnt/cdrom

or

eject (to eject disc)

4 Reboot the system to enable the new/updated driver.

2-5

Page 13: M sata raid_adaptec

Installing the Driver

Installing the Netware Driver in a New NetWare System

Note: For information about installing drivers if you use the NetWare CD to install your operating system, see your Novell documentation.

Use these steps to install the driver in a new Novell NetWare 6.5 system. To install the driver:

1 Use the instructions provided in the NetWare manual to begin the installation.

2 When the Choose the Server Drivers - Disk Driver prompt appears during the installation process, select Storage adapters; then, press Enter.

3 If the list contains the HostRAID SATA driver (AARICH.HAM) or (AAR81XX.HAM), select the driver then press the Delete key to delete it.

4 Press the Insert key twice to Add an unlisted driver.

5 Insert the support diskette for Novell NetWare.

6 Press F3 to specify a path then type a:\ (where a is the diskette drive letter) then press Enter.

Note: The driver and support files will be copied to the system volume: either AARICH.HAM or AAR81XX.HAM.

7 Verify that the driver name displays in the list of device drivers that appears in the window (for example, AARICH.HAM) then select Return to Driver Summary then press Enter.

8 Select Continue then press Enter.

9 Follow the instructions in the NetWare manual to complete the installation.

2-6

Page 14: M sata raid_adaptec

Installing the Driver

Installing or updating device drivers after installing NetWare To update the driver in an existing NetWare 6.5 system see Updating the Device Drivers. To install the driver in an existing NetWare system, see Installing the Device Drivers.

Updating the Device Drivers1 From the system console, type the following and press Enter

then:

Unload driver_name

where

driver_name is AARICH or AAR81XX

For example:

Unload AARICH

2 Do not restart the system; continue with the instructions for Installing the Device Drivers.

Installing the Device Drivers1 Start the NetWare hdetect utility program. From the system

console, type the following then press Enter:

load hdetect

2 Insert the HostRAID support diskette for Novell NetWare into the floppy diskette drive.

3 When you see the prompt Sys volume not mounted. Load driver anyway?, select Yes then press Enter to continue.

4 The device driver window opens, showing a list of storage adapters. Select Modify.

5 Press Enter to continue then select Modify.

6 Select the driver then press the Delete key to delete it.

7 When the next window opens, press the Insert key twice to add a driver.

2-7

Page 15: M sata raid_adaptec

Installing the Driver

8 When the next window opens, press F3 to specify a different path.

9 In the Specify a directory path field, type a:\ (where a is the diskette drive letter) then press Enter.

10 After the installation program copies all the files, press Esc to exit the hdetect utility.

Note: If you want NetWare to load the HostRAID device driver automatically during startup, you must add the appropriate LOAD command to the NetWare startup command file (usually C:\NWSERVER\STARTUP.NCF). The command has the form:load [pathname]driverslot=number [options]

For example:

load c:\nwserver\a320raid.ham slot=1

2-8

Page 16: M sata raid_adaptec

3

Installing and Starting Adaptec Storage ManagerIn this Chapter...

After you have installed your Adaptec RAID controller and driver, you are ready to install and use Adaptec Storage Manager—a user-friendly graphical user interface (GUI) that makes it easy for you to create and manage arrays without having to restart the computer and use the BIOS utility.

Note: You need administrator or root privileges to install Storage Manager. For details on verifying privileges, refer to your operating system documentation.

Installing Storage Manager on Windows 3-2

Installing Storage Manager on Linux 3-3

Installing Storage Manager on NetWare 3-4

Starting Storage Manager 3-5

Logging into Remote Systems 3-5

3-1

Page 17: M sata raid_adaptec

Installing and Starting Adaptec Storage Manager

Installing Storage Manager on WindowsThis section provides instructions for installing Storage Manager.

Note: On Windows, Storage Manager supports up to 16 Adaptec RAID controllers.

To install Storage Manager:

1 Insert the product installation CD and wait for the Autorun executable to start the installation. If this does not occur, browse the CD and click Autorun.

2 When the installation wizard starts, follow the instructions on the screen to complete the installation.

Note: When prompted to install SNMP (Simple Network Management Protocol), accept the default (do not install) unless you have a specific requirement for Storage Manager to work with SNMP gets and traps.

3-2

Page 18: M sata raid_adaptec

Installing and Starting Adaptec Storage Manager

Installing Storage Manager on Linux

Notes:

■ With Linux, Storage Manager supports up to 12 Adaptec RAID controllers.

■ Storage Manager includes the Java Runtime Environment (JRE).

■ If a previous version of Storage Manager is already installed and you are upgrading, you must first remove that version. Any customization files you may have created when you used the previous version are saved and used in the upgrade. To remove Storage Manager, type the rpm --erase StorMan command.

■ For the latest on Adaptec’s support of Linux, visit www.adaptec.com.

To install Storage Manager:

1 Insert the product installation CD.

2 Mount the product installation CD:

3 Change to the cdrom directory:

4 Extract the RPM package and install it:

rpm --install ./StorMan*.rpm

5 Unmount the product installation CD:

for Red Hat mount /dev/cdrom /mnt/cdrom

for SuSE mount /dev/cdrom /media/cdrom

for Red Hat cd /mnt/cdrom/linux/manager

for SuSE cd /media/cdrom/linux/manager

for Red Hat umount /mnt/cdrom

for SuSE umount /media/cdrom

3-3

Page 19: M sata raid_adaptec

Installing and Starting Adaptec Storage Manager

Installing Storage Manager on NetWare

Notes:

■ With NetWare, Storage Manager supports up to 16 Adaptec RAID controllers.

■ You need the latest Support Pack for your operating system so you can run the supported Java Virtual Machine (JVM).

■ You need JVM version 1.3 or later. To check your JVM version, load JVM, type JAVA -VERSION.

■ For the latest updates from Novell, visit www.novell.com.

To install Storage Manager:

1 Insert the product installation CD.

2 From the command prompt, type load cdrom then press Enter.

3 From the command prompt, type:

RaidMan:\netware\manager\install

The installation program starts.

4 Follow the instructions on the screen to complete the installation.

3-4

Page 20: M sata raid_adaptec

Installing and Starting Adaptec Storage Manager

Starting Storage Manager

Note: You need root privileges to run Storage Manager.

To start Storage Manager, use the procedure outlined in the table below for your operating system.

Logging into Remote SystemsTo log into a remote system:

1 Click Remote > Add Remote System.

Storage Manager displays the login screen, as shown below.

If your operating system is... Start Storage Manager as follows...

Windows To run Storage Manager as a standalone application, click Start > Programs > Adaptec Storage Manager, then select the appropriate icon.

Linux Change to the directory where you installed Storage Manager by typing cd /usr/RaidMan then use the sh RaidMan.sh shell command.

NetWare Type the LOAD RAIDMAN command.

3-5

Page 21: M sata raid_adaptec

Installing and Starting Adaptec Storage Manager

2 Type the IP address.

The default System startup port number, 34571, is supplied for you.

3 For Username, type admin

4 For Password, type adaptec

Note: The username and password are case sensitive.

Once you are logged in for the first time, you can add new accounts and change account passwords. For details, refer to the online Help.

3-6

Page 22: M sata raid_adaptec

4

Understanding Adaptec Storage ManagerIn this Chapter...

IntroductionThis chapter provides an overview of Adaptec Storage Manager, the user-friendly GUI that you use to easily create and manage arrays. For more details on using Adaptec Storage Manager to set up and manage arrays, refer to the online Help.

FeaturesYou can use Adaptec Storage Manager to:

■ Create and delete arrays

■ Verify arrays

■ Migrate arrays

■ Add and remove hotspares

■ Change RAID level

Introduction 4-1

Overview 4-2

Changing How Drives are Displayed 4-4

Collapsed and Expanded Views 4-4

Component Views 4-5

4-1

Page 23: M sata raid_adaptec

Understanding Adaptec Storage Manager

■ View the RAID configuration

■ View information about managed systems and subsystems such as arrays, logical drives, hot-spare drives, physical drives

■ Notify systems of all events occurring on the local system

■ Increase logical device size

■ Manage scheduled tasks such as Verify or Migrate

■ Add or remove a remote system

■ Configure, administer, and monitor controllers that are installed locally or remotely in your servers or external storage

■ Fine tune controller settings for optimal performance

Note: Some of these features may not be available on your system. Check with your vendor, product documentation, or online Help for supported features.

OverviewAdaptec Storage Manager provides an expandable tree view of the systems and controllers you are managing. You can perform most configuration and management tasks by selecting a controller from the tree and working with related objects. The figure below shows how Adaptec Storage Manager displays information about Physical and Logical devices.

4-2

Page 24: M sata raid_adaptec

Understanding Adaptec Storage Manager

Using the buttons in the Physical devices and Logical devices views, you can:

■ Change how drives are displayed.

■ Collapse and expand a view.

■ Identify components of a logical device.

■ Create and delete hotspares.

Physical Devices ViewThis view displays information about the drives, enclosures, and other physical devices attached to the controller. The devices are organized numerically. The display for each channel or port includes information on maximum speed, the number of the channels on the controller, and the number of devices attached to the controller.

Indicators, next to the controller name, report status of the fan and temperature modules on SAF-TE (enclosure management) devices and other devices that monitor these conditions. The indicator colors are:■ Blue—Normal■ Yellow—Warning■ Red—Error■ Gray—Not applicable to the devices.

For example, the fan indicator changes to yellow when one fan fails; it changes to red when a second fan fails and cooling is no longer adequate.

Logical Devices ViewThis view displays information about the logical devices created using the physical devices, including the number of logical devices, the RAID level of each device, and whether a logical device is protected by a hotspare.

You can create and delete logical devices in the Logical devices view by selecting the Create option and using the Create wizard.

4-3

Page 25: M sata raid_adaptec

Understanding Adaptec Storage Manager

Changing How Drives are DisplayedYou can choose how information is displayed in the Physical devices view by clicking one of the following buttons in the Logical devices view.

Collapsed and Expanded ViewsYou can display a collapsed or expanded view of the system configuration. Initially, Storage Manager displays a collapsed textual view of the configuration information in both the Logical devices and Physical devices views.

Displays physical device information in text format. This is the default view.

Displays physical device information in full size capacity format. A full-length bar is displayed for each drive, regardless of capacity. A small segment on each drive is reserved for the RAID signature; this area is indicated by a gray cap at the end of each bar.Note: A drive shaded in light blue is not part of any disk group.

Displays physical device information in relative size capacity format. A full-length bar is displayed for the largest drive; proportionally shorter bars are displayed for other drives.

In the Logical devices view...Click to expand and collapse information about disk groups and logical devices. The expanded display shows the following information about each logical device:■ Disk group name and capacity (if available) ■ Logical device size ■ Logical device state ■ Build progress

In the Physical devices view...Click to expand and collapse information about physical drives. The expanded display shows the following information about each drive: ■ Capacity of the drive■ Drive ID ■ Drive state

4-4

Page 26: M sata raid_adaptec

Understanding Adaptec Storage Manager

Component ViewsWhen you click a physical or logical device in the device views, the related components are highlighted in the other view.

■ When you click a logical device in the Logical devices view, the physical drives that make up the logical device are highlighted in the Physical devices view, and vice-versa.

■ When you click a hotspare, the logical devices protected by that spare are highlighted.

■ In the graphical views, if the logical device uses only part of the available storage, only those segments are highlighted (in dark blue).

4-5

Page 27: M sata raid_adaptec

5

Adaptec RAID Configuration UtilityIn this Chapter...

The Adaptec RAID Configuration (ARC) utility is an embedded BIOS utility that includes:

■ Array Configuration Utility (ACU)—Used to create, configure, and manage arrays.

■ Disk Utilities—Used to format or verify disks.

To run ARC, press Ctrl+A when prompted by the following message during the system startup:

Press <Ctrl><A> for Adaptec RAID Configuration Utility

The ARC menu appears, presenting these options:

■ Array Configuration Utility (ACU)

■ Disk utilities

To select an option from this menu, or from any of the menus within ARC, browse with the arrow keys, then press Enter. In some cases, selecting an options displays another menu. To return to the previous menu at any time, press Esc.

Using the Array Configuration Utility 5-2

Using the Disk Utilities 5-8

5-1

Page 28: M sata raid_adaptec

Adaptec RAID Configuration Utility

Using the Array Configuration UtilityThe Array Configuration Utility (ACU) enables you to create, manage, and delete arrays from the controller’s BIOS, add and delete spare drives, and initialize drives.

Managing ArraysSelect the Manage Arrays option to view array properties and members, and delete arrays. The following sections describe these operations in greater detail.

Viewing Array Properties

To view the properties of an existing array:

1 At the BIOS prompt, press Ctrl+A.

2 From the ARC menu, select Array Configuration Utility (ACU).

3 From the ACU menu, select Manage Arrays.

4 From the List of Arrays dialog box, select the array you want to view then press Enter.

The Array Properties dialog box appears, showing detailed information on the array. The physical disks associated with the array are displayed here.

5 Press Esc to return to the previous menu.

Deleting Arrays

Caution: Back up the data on an array before you delete it. Otherwise, all data on the array is lost. Deleted arrays cannot be restored.

To delete an existing array:

1 Turn on your computer and press Ctrl+A when prompted to access the ARC utility.

2 From the ARC menu, select Array Configuration Utility (ACU).

3 From the ACU menu, select Manage Arrays.

!

5-2

Page 29: M sata raid_adaptec

Adaptec RAID Configuration Utility

4 Select the array you wish to delete then press Delete.

5 In the Array Properties dialog box, select Delete then press Enter. The following prompt is displayed:

Warning!! Deleting the array will render array unusable. Do you want to delete the array?(Yes/No):

6 If you press Yes, select the member when the following prompt is displayed:

To delete the partition table, choose which member: member #0, member #1, both, none

7 Press Esc to return to the previous menu.

Creating ArraysBefore creating arrays, make sure the disks for the array are connected and installed in your system. Note that disks with no usable space are shown in gray and cannot be used. See Initializing Disk Drives on page 5-6.

To create an array:

1 Turn on your computer and press Ctrl+A when prompted to access the ARC utility.

2 From the ARC menu, select Array Configuration Utility (ACU).

3 From the ACU menu, select Create Array.

4 Select the disks for the new array then press Insert. To deselect any disk, highlight the disk then press Delete.

5 Press Enter when both disks for the new array are selected. The Array Properties menu displays.

Assigning Array Properties

Note: Once the array is created and its properties are assigned, you cannot change the array properties using the ACU. Instead, use Adaptec Storage Manager (See Chapter 4 for details.)

5-3

Page 30: M sata raid_adaptec

Adaptec RAID Configuration Utility

To assign properties to the new array:

1 In the Array Properties menu, select an array type then press Enter. Note that only the available array types, RAID 0, RAID 1 and RAID 10 are displayed. RAID 0 and RAID 1 requires two drives. RAID 10 requires four drives.

2 Type in an optional label of no more than 15 characters for the array, then press Enter.

3 For RAID 0, select the desired stripe size. Available stripe sizes are 16, 32, and 64 KB (default).

Note: Adaptec recommends that you do not change the default.

4 The options under Create Using allows you to select between the different creation methods for RAID 0, RAID 1, and RAID 10. The following table gives examples of when each is appropriate.

RAID Level

Create Using When Appropriate

RAID 0 No Init Creating a RAID 0 on new drives.

RAID 0 Migrate1

1 If you select Migrate for RAID 0 or Build for RAID 1 or RAID 10, you will be asked to select the source drive. The contents of the source drive will be preserved. However, the data on the new drive will be lost.

Creating a RAID 0 from one new drive and one drive with data you wish to preserve.

RAID 1 Build1 Any time you wish to create a RAID 1, but especially if you have data on one drive that you wish to preserve.

RAID 1RAID 10

Clear Creating a RAID 1 or RAID 10 on new drives, or when you want to ensure that the array contains no data after creation.

RAID 1RAID 10

Quick Init

Fastest way to create a RAID 1or RAID 10. Appropriate when using new drives.

5-4

Page 31: M sata raid_adaptec

Adaptec RAID Configuration Utility

Notes:

■ Before adding a new drive to an array, back up any data contained on the new drive. Otherwise, all data will be lost.

■ If you stop the Build or Clear process on a RAID 1 or RAID 10 from ACU, you can restart it by pressing Ctrl+R.

■ A RAID 1 created using the Quick Init option may return some data miscompares if you later run a consistency check. This is normal and is not a cause for concern.

■ The ACU allows you to use drives of different sizes in a RAID 1 or RAID 10. However, during a build operation , only the smaller drive can be selected as the source or first drive.

■ When migrating from single volume to RAID 0, migrating from a larger drive to a smaller drive is allowed. However, the destination drive must be at least half the capacity of the source drive.

■ Adaptec does not recommend that you migrate or build an array on Windows dynamic disks (volumes), as it will result in data loss.

Caution: Do not interrupt the creation of a RAID 0 using the Migrate option. If you do, there is no way to restart, and no way to recover the data that was on the source drive.

5 When you are finished, press Done.

Adding/Removing a Bootable Array

To make an array bootable:

1 From the Main menu, select Manage Arrays.

2 From the List of Arrays, select the array you want to make bootable, then press Ctrl+B. An asterisk will appear next to the bootable array.

3 To make the array nonbootable, select it then press Ctrl+B. The asterisk will disappear next to the array indicating that it is nonbootable.

!

5-5

Page 32: M sata raid_adaptec

Adaptec RAID Configuration Utility

Add/Delete HotsparesSelect the Add/Delete Hotspares option to add, delete, or view hot spares.

1 Turn on your computer and press Ctrl+A when prompted to access the ARC utility.

2 From the ARC menu, select Array Configuration Utility (ACU).

3 From the ACU menu, select Add/Delete Hotspares.

4 Use the up and down arrow keys to highlight the disk you want to designate as a Hotspare, then press Insert>Enter.

5 Press Yes when the following prompt is displayed:

Do you want to create spare? (Yes/No)

The Spare you have selected will appear in the Selected Drive menu.

Initializing Disk Drives

Caution: If the drive is used in an array, you may not be able to use the array again. Do not initialize a disk that is part of a boot array. To determine which disks are associated with a particular array, see Viewing Array Properties on page 5-2.

To initialize drives:

1 Turn on your computer and press Ctrl+A when prompted to access the ARC utility.

2 From the ARC menu, select Array Configuration Utility (ACU).

3 Select Initialize Drives.

4 Use the up and down arrow keys to highlight the disk you wish to initialize then press Insert.

5 Repeat Step 4 if you want to add another drive to be initialized.

6 Press Enter.

!

5-6

Page 33: M sata raid_adaptec

Adaptec RAID Configuration Utility

7 Read the warning message and ensure that you have selected the correct disk drives to initialize. Type Y to continue.

Rebuilding Arrays

Note: Rebuilding applies to Fault Tolerant arrays (RAID 1 and RAID 10) only.

By replacing a failed disk of a RAID 1 or RAID 10 array with a new disk, you can Rebuild to get the array to Optimal status and assume fault tolerance. You can perform a Rebuild in the following ways:

Note: If no spare exists and a hard disk drive fails, you need to create a spare before you can rebuild an array. See Add/Delete Hotspares on page 5-6 before continuing your Rebuild.

System Shutdown Rebuild

You can shutdown the system and replace the failed disk with a new one (of equal or greater capacity). Once the system is booted, a new drive can be assigned as the spare drive, and this will start the Rebuild task. All the data from the good disk is copied to the new one, and the original RAID 1 or RAID 10 array is recreated.

Manual Rebuild

1 From the Main Menu, select Manage Arrays. From the List of Arrays, select the array you want to Rebuild.

2 Press Ctrl+R to Rebuild.

5-7

Page 34: M sata raid_adaptec

Adaptec RAID Configuration Utility

Verifying DrivesIf you are notified of a mismatch of data during a build of RAID 1 or RAID 10, you have an option of verifying your drives. To Verify the drives:

Note: You will only have the Verify option available if the array is Optimal. If the array has failed, you will need to rebuild the array.

1 Select the drives you need to verify.

2 Press Ctrl+S.

3 When the Verify is complete, you will be notified with any errors found during the Verify operation.

Using the Disk UtilitiesThe Disk Utilities enable you to format or verify the media of your Serial ATA hard disks.

To access the disk utilities:

1 Turn on your computer and press Ctrl+A when prompted to access the ARC utility.

2 From the ARC menu, select Disk Utilities.

3 Select the desired disk then press Enter.

You are offered the following options:

■ Format Disk—Simulates a low-level format of the hard drive by writing zeros to the entire disk. Serial ATA drives are low-level formatted at the factory and do not need to be low-level formatted again.

Caution: Formatting destroys all data on the drive. Be sure to back up your data before performing this operation.

■ Verify Disk Media—Scans the media of a disk drive for defects.

!

5-8

Page 35: M sata raid_adaptec

Glossary

Aactivity

See task.

ACU

Array Configuration Utility. An application used to create, configure, and manage arrays from the controller’s BIOS or MS-DOS.

array

A logical disk created from available space and made up of one or more segments on one or more physical disks. Arrays are typically used to provide data redundancy or enhanced I/O performance. See also volume, spanned volume, RAID 0, RAID 1. Also known as a container.

array initialization

See initialize.

ATA

AT Bus Attachment. Standard parallel interface to IDE hard disks typically used in desktop computers and some entry-level servers. Serial ATA (SATA), is a successor to parallel ATA, which is sometimes referred to as PATA.

available space/segment

Unused space on an initialized disk from which logical devices (arrays) are created. When an array is deleted, the space that it used is returned to the available space pool.

Glossary-1

Page 36: M sata raid_adaptec

Glossary

Bbackground consistency check

Option that forces the controller to constantly check all portions of disks used by all arrays to see if the disks can return data from the blocks. See also consistency check command.

bad segment

Segment that is in an unknown state.

bootable array

Array configured as the boot device.

build

Background initialization of a redundant array. The array is accessible throughout. RAID 1 copies the contents of the primary drive to a secondary drive. See also clear.

bus

See channel.

Ccache

Fast-access memory on the controller that serves as intermediate storage for data that is read from, or written to, drives.

capacity

Total usable space available in megabytes or gigabytes.

channel

Any path, or bus, used for the transfer of data and the control of information between storage devices and a RAID controller. For SATA channels, each channel has a single drive capacity.

Glossary-2

Page 37: M sata raid_adaptec

Glossary

check pointA feature that enables you to exit the ACU when an operation is in progress and be able to continue without interruption. The driver then resumes the operation from where the BIOS left off and the BIOS resumes the operation where the driver left off.

chunk

See stripe.

clear

Foreground initialization of a fault-tolerant array. A clear operation zeros all blocks of the array. The array is not accessible until the clear task is complete.

concatenation

Joining of physical or logical drives in sequential order.

consistency check command

Command that reads all the blocks of a RAID 1 to determine if the blocks are consistent. Any inconsistent blocks are fixed.

Ddead partition

See failed.

degraded

A redundant (for example, a RAID 1) array in which one or more members have failed. The data is intact but redundancy has been compromised. Any further failure would cause the array to fail and result in data loss.

disk

Physical disk drive. Randomly accessible, rewritable data storage device. Also called hard disk.

disk ID

Unique disk identifier that consists of the channel number, SATA ID. For example, (channel:ID:LUN) 1:04:0. See also channel.

Glossary-3

Page 38: M sata raid_adaptec

Glossary

drive LED

Disk indicator LED that illuminates during read or write operations.

Eevent

Notification or alert from the system, indicating that a change has occurred.

event log

File used to maintain information about prior controller activities or errors.

event notification

Process for transmitting events.

Ffailed

State of a nonredundant array that has suffered a single drive failure, or a redundant array that has suffered multiple drive failures. A failed array is inaccessible and data is lost.

fault-tolerant array

Refers to an array that can continue to function after a disk drive failure without loss of data. Fault tolerant, or redundant arrays, include RAID 1 arrays. See also Redundant.

foreign disk

Disk that has previously been initialized on another Adaptec RAID controller. The RAID signature on the disk allows the RAID controller to identify whether or not the disk was initialized on the controller it is currently connected to.

Glossary-4

Page 39: M sata raid_adaptec

Glossary

Hhard disk drive

Basic unit of nonvolatile, nonremovable, magnetic storage media. See also disk.

hot swap

To remove a component from a system, and install a new component while the power is on and the system is running.

hotspare

A spare hard disk that automatically replaces a failed hard disk on any array associated with any HBA.

Iimpacted

An impacted array is one which has been created but for some reason the initial build operation did not complete. All member drives are present and operational, and all data written to the array is protected. To optimize the array, run a Verify with Fix Task.

initialize

Process of preparing a disk for use by the controller. When a disk is initialized, the controller records the RAID signature on the disk.

initialized array

An array that is ready for data reads and writes. Arrays can be initialized by build or clear.

Llegacy disk

Disk that contained a valid partition table when connected to the controller. The controller manages the disk as a legacy disk array where there is a one-to-one logical-to-physical mapping of array to disk.

Glossary-5

Page 40: M sata raid_adaptec

Glossary

logical device

Volume comprised of space from one or more physical drives and presented to the operating system as if it were a single storage unit.

low-level format

Process performed by the drive firmware that completely cleans any data off the hard disk.

Mmirrored array/mirroring

See RAID 1.

monitoring

Process of receiving, displaying, and logging system events.

Ooffline array

Array that can no longer be accessed.

optimal

The state of an array when it is fully operational. For redundant arrays, the entire array is protected.

Ppartition

A section of a disk storage device created by the operating system disk management program, in which data and/or software programs are stored. Computers have a primary operating system partition that contains the special files needed to boot the computer. Each operating system partition is assigned a unique drive letter, such as C or D. A single disk device can have multiple partitions.

phantom object

Object that represents a component that cannot be configured by the controller management software; for example, a missing drive.

Glossary-6

Page 41: M sata raid_adaptec

Glossary

Qquick init

An array initialized using the Quick Init option is available immediately, with no on-going background controller activity. All data written to an array that has been quick initialized is protected.

RRAID

Redundant Array of Independent Disks (alternative definition Redundant Array of Inexpensive Disks).

RAID 0

A single-level array consisting of two or more equal-sized segments residing on different disks. RAID 0 distributes data evenly across its respective drives in equal-sized sections called stripes. RAID 0 arrays are not redundant.

RAID 1

Single-level array consisting of two equal segments residing on two different drives. Provides redundancy by storing identical copies on two drives.

See also mirrored array/mirroring.

RAID signature

The area on each disk reserved for use by the RAID controller.

RAID volume

Concatenates two or more arrays of the same type.

rebuild

Background regeneration of redundant data on a RAID 1.

redundant

The ability of an array to maintain operability when one or more hardware failures occur. RAID 1 is redundant. In the event of a drive failure, redundant arrays can be restored to normal operation by replacing the failed drive and rebuilding the array.

Glossary-7

Page 42: M sata raid_adaptec

Glossary

rescan

Process of updating the current screen to show all currently available resources.

SSerial ATA (SATA)

A successor to ATA that uses a serial, instead of parallel, interface.

simple volume

A volume made up of disk space from a single disk. It can consist of a single region on a disk, or concatenated multiple regions of the same disk.

single-level array

Array created from one or more segments. See also volume, spanned volume, RAID 0, RAID 1.

snapshot

Instantaneous read-only copy of an array at a precise point in time.

spanned volume

A simple volume that spans two or more drives.

stripe

Contiguous set of data distributed across all the disks in an array. A striped array distributes data evenly across all members in equal-sized sections called stripes.

stripe size

The amount of data in each section of a striped array.

striped array

See RAID 0.

Glossary-8

Page 43: M sata raid_adaptec

Glossary

Ttask

An operation that occurs only on the RAID controller, asynchronous to all other operations; for example, initializing a disk or verifying an array. Some tasks can take an extended period of time, particularly if the RAID controller is also performing intensive data I/O while the task is running.

Vverify

Low-level check that a drive, logical device, or hot spare is good. In a RAID 1, verify is a low-level check that contents of both members’ segments are consistent and, optionally, corrects errors while assuming that the master drive is correct. In a simple volume, verify performs a low-level check that the whole drive can be read.

volume

See simple volume, spanned volume.

Glossary-9

Page 44: M sata raid_adaptec

Index

AACU

overview 1-3using to manage arrays 5-2

Adaptec RAID Configuration utilityoverview 1-3

Adaptec Storage componet views4-5

Adaptec Storage Managerfeatures 4-1logical devices view 4-3overview 1-3, 4-2physical devices view 4-3

Array Configuration Utility. See ACU

Array Properties dialog boxdeleting arrays 5-3

Arrayscreating bootable arrays 5-2

arraysstripe size 5-4

BBootable arrays

creating 5-2

CCaching

read 5-4Containers

creating with CCU 5-3deleting 5-2managing with CCU 5-2

Ddevice drivers

installingNetWare 2-7

updatingNetWare 2-7

Disk Size Advisory 5-2Disks

initializing 5-6size advisory 5-2

driver installationinstalling in existing Linux

system 2-5installing in existing NetWare

system 2-7installing in existing Windows

system 2-3installing in new Linux system

2-3installing in new NetWare

system 2-6installing in new Windows

system 2-2

Ffeatures 1-2Format disk 5-8

HHostRAID

overview 1-1

IInitializing Disks 5-6initializing drives 5-6installing NetWare driver 2-6

Index-1

Page 45: M sata raid_adaptec

Index

LLinux driver installation

in existing system 2-5in new system 2-3

MManage Arrays option 5-2

NNetWare

device drivers 2-7NetWare driver installation 2-6

Ooperating system compatibility

1-2

RRead caching 5-4Rebuilding arrays 5-7

SSCSI Disk Utilities 5-8storage management

software overview 1-3storage requirements 1-2stripe size 5-4

VVerify disk media 5-8verifying drives 5-8

WWindows driver installation

in existing system 2-3in new system 2-2

Index-2

Page 46: M sata raid_adaptec

R

Adaptec, Inc.691 South Milpitas BoulevardMilpitas, CA 95035 USA

©2004 Adaptec, Inc.All rights reserved. Adaptec and the Adaptec logo are trademarks of Adaptec, Inc. which may beregistered in some jurisdictions.

Part Number: 513944-06, Ver. AA JG 07/04