Industry Leader Since 1969 Made in the USA M-2980A Weatherproof Capacitor Control Cabinet NEMA ® 4x rated enclosures available in the following construction materials: – Nonmetallic Polycarbonate – Molded Lexan – Cold Rolled Steel – Stainless Steel UV resistant Locking clasps accept 3/8" hasp locks Flexible configurations allow adaptation to a wide range of applications Molded Lexan ® Enclosure Shown With Optional M-6280A Capacitor Bank Control

Transcript of M-2980A Weatherproof Capacitor Control Cabinet · M-2980A Weatherproof Capacitor Control Cabinet...

Industry Leader Since 1969Made in the USA

M-2980A Weatherproof Capacitor ControlCabinet

• NEMA® 4x rated enclosures available in the following construction materials:

– Nonmetallic Polycarbonate – Molded Lexan – Cold Rolled Steel – Stainless Steel

• UV resistant

• Locking clasps accept 3/8" hasp locks

• Flexible configurations allow adaptation to a wide range of applications

Molded Lexan® Enclosure Shown With Optional M-6280A Capacitor Bank Control

M‑2980A Capacitor Control Cabinet

–2–

ApplicationEach M-2980A enclosure can be configured with the optional support equipment to match the existing control application and environment or supplied completely empty. See the Optional Equipment section for details regarding the optional equipment available.

ConstructionPolycarbonate

• Body and door fabricated from nonmetallic polycarbonate

• EPDM gasket (ethylene propylene diene Monomer- M-class)

• External adjustable mounting bracket

• Nonmetallic door hinges

• Enclosure door accommodates optional power supplies, battery and communications devices

• External Grounding stud provided

Molded Lexan®

• Body and door fabricated from molded Lexan

• EXL 9330 Copolymer (.150" nominal thickness)

• UV Inhibitor

• Passed drop test on all eight corners

• Flame Retardant UL 94V-0

• NEMA 4X water ingress and corrosion protection

• Stronger than standard polycarbonate

• Excellent low temperature impact strength (11 ft. lb./in. @ -60° F) ASTM D256

• Silicone closed cell gasket

• External adjustable mounting bracket

• Integral door hinges with stainless steel hinge pin

• Enclosure door accommodates optional power supplies, battery and communications devices

• External Grounding stud provided

Cold Rolled Steel/Stainless Steel (304)

• Body and door fabricated from 14/16 gauge steel

• Continuously welded seams ground smooth

• Closed cell neoprene gasket

• External adjustable mounting bracket

• Stainless steel door hinge

• Enclosure accommodates optional power supplies, battery and communications devices

• External Grounding stud provided

• Powder coated, ANSI 70 Grey

Lexan is a registered trademark of General Electric company

–3–

M‑2980A Capacitor Control Cabinet

Cabinet to Capacitor Bank Interface Type • Meter Socket Mount

– Integrated 4, 5 or 6 Blade (4 Blade Standard) Meter Socket Plug

– Standard Meter Socket Plug wiring is available in factory 4, 5 and 6 Blade configuration (4S, 5S and 6S) (Figure 1)

– Optional custom factory Meter Socket Plug wiring configurations available (Figure 1)

• Direct Pole-Mount with cabled Meter Socket Plug

– 4, 5, or 6 Blade (4 Blade standard) Meter Socket Plug with standard five foot control cable

– Standard Meter Socket Plug wiring is available in factory 4, 5 and 6 Blade configuration

– Optional cable lengths available in five foot increments up to 50 feet

– Optional Factory Meter Socket Plug Custom Wiring Configurations available (Figure 1)

• Direct Pole-Mount with Cannon Connector, Integrated

– 5-Pin Cannon Connector (Figure 2), Cannon Bulkhead Shell 18-21

– 7-Pin Cannon Connector (Figure 3), Cannon Bulkhead Shell 20-15

– Optional 5 and 7-Pin wiring configurations available (Figures 2 and 3)

• Direct Pole-Mount with Cannon Connector, Cabled

– 5-Pin Cannon Connector Shell 18-21 (Figure 2)

– 7-Pin Cannon Connector Shell 20-15 (Figure 3)

– Optional 5 and 7-Pin wiring configurations available (Figures 2 and 3)

– Optional cable lengths available in five foot increments up to 50 feet

• Direct Pole-Mount with cable only, no connector

M‑2980A Capacitor Control Cabinet

–4–

4 Blade Selection

Config

4S

1 2 3 4

41

42

43

5 Blade Selection

1 2 3 4 5Config

5S

51

6 Blade Selection

Config 1 2 3 4 5 6

Meter Socket Wiring

6S

61

62

63

64

65

66

67

68

Line Neutral OPEN CLOSE

Neutral Line OPEN CLOSE

Neutral Line CLOSE OPEN

Line Neutral CLOSE OPEN

Line Neutral OPEN CLOSE

Line Neutral OPEN CLOSE

NC POL

LC POL

CLOSE

CLOSE

CLOSE

CLOSE

CLOSE

CLOSE

CLOSE

CLOSE

CLOSE

OPEN

OPEN

OPEN

OPEN

OPEN

OPEN

OPEN

OPEN

Neutral

Neutral

Neutral

Neutral

Neutral

Neutral

Neutral

Neutral

Neutral

Line

Line

Line

Line

Line

Line

Line

Line

Line

LC POL

LC POL

LC POL

LC POL

LC POL

OPEN

LC POL

LC RTN

LC RTN

NC POL

NC POL

NC POL

- - - - - - - - - - - -

- - - - - -

LC RTN

ALT LC POL

LC POL

NC RTN

1 2

3 4

1 2

3 45

1 2

5 63

4

4 Jaw Base

5 Jaw Base

6 Jaw Base

View as shown, is peering into female Meter Socket

69 CLOSEOPENNeutralLine - - - - - - - - - - - -

▲ CAUTION: Neutral Current or Phase Current input wires located in the same physical cable as Line-in, Open, and Close wiring may experience induced Neutral Current and/or Phase Current transients during Opening and Closing operations.

Figure 1 Standard (S) and Optional Factory Meter Socket Plug Custom Wiring Configurations

–5–

M‑2980A Capacitor Control Cabinet

PIN

A B C D EConfig

5N

5L

Line Neutral CLOSE OPEN NC POL

5-Pin Cannon Plug/Control Wiring

TB1-10 TB1-8 TB1-5 TB1-6Control TB1-14

Control

Line Neutral CLOSE OPEN LC POL

TB1-10 TB1-8 TB1-5 TB1-6 TB2-5

5E Line Neutral CLOSE OPEN - - - - - -

TB1-10 TB1-8 TB1-5 TB1-6Control - - - - - -

5-Pin PlugC

D

B

A

ENC POL - Neutral Current PolarityLC POL - Line Current PolarityNC RTN - Neutral Current ReturnLC RTN - Load Current Return

▲ CAUTION: Neutral Current or Phase Current input wires located in the same physical cable as Line-in, Open, and Close wiring may experience induced Neutral Current and/or Phase Current transients during Opening and Closing operations.

Figure 2 5-Pin Cannon Plug Configurations

M‑2980A Capacitor Control Cabinet

–6–

PIN

A B C D EConfig

7B

7E

Line OPEN CLOSE NC POL

7-Pin Cannon Plug/Control Wiring

TB1-10 TB1-6 TB1-5- - - - - -

Control TB1-14

Control

Line OPEN CLOSE NC POL

TB1-10 TB1-6 TB1-5NC & LC RTN

TB1-14

7A Line OPEN CLOSE

TB1-10 TB1-6 TB1-5- - - - - -

Control- - - - - -

F G

NC POL Neutral

TB1-14 TB1-8

LC POL Neutral

TB2-5 TB1-8

LC POL Neutral

TB2-5 TB1-8

7-Pin Plug

D

E

F

C

B

A

GNC POL - Neutral Current PolarityLC POL - Line Current PolarityNC RTN - Neutral Current ReturnLC RTN - Load Current Return

7C Line Neutral CLOSE OPEN

TB1-10 TB1-8 TB1-5Control TB1-6

LC POL LC RTN

TB2-5 TB2-4

7D Line OPENCLOSENC POL

TB1-10 TB1-6TB1-5- - - - - -

Control TB1-14

LC POL

TB2-5

7F Line OPENCLOSE

TB1-10 TB1-6TB1-5GROUND

Control

LC POLNeutral

TB2-5TB1-8

- - - - - -

NC & LC RTN

LC RTN

TB2-4

▲ CAUTION: Neutral Current or Phase Current input wires located in the same physical cable as Line-in, Open, and Close wiring may experience induced Neutral Current and/or Phase Current transients during Opening and Closing operations.

Figure 3 7-Pin Cannon Plug Configurations

–7–

M‑2980A Capacitor Control Cabinet

PIN

A B C

NC POL NC RTN Ground

3-Pin Cannon Connector/Control Wiring

TB1-14 TB1-15 Enclosure Ground Stud

LC POL LC RTN Ground

TB2-5 TB2-4 Enclosure Ground Stud

Config

Neutral Current50:0.2 CT

Control

Line Current LinePost Sensor

Control

A B CConfig

Wire color codingdoes not apply tocontrol terminal blockwiring.

*

Wire color coding doesnot apply to controlterminal block wiring.

*

3-Pin Socket(Cabinet Side)

B-White*(LC RTN)

C-Green* orBare Wire

A-BLACK*(LC POL)

3-Pin Plug(Cabinet Side)

B-Red*(NC RTN)

C-Shield

A-BLACK*(NC POL)

LC POL - Line Current PolarityLC RTN - Load Current Return

NC POL - Neutral Current PolarityNC RTN - Neutral Current Return

Figure 4 3-Pin Cannon Plug Configurations

M‑2980A Capacitor Control Cabinet

–8–

Optional Equipment/Accessories • M-6280A Digital Capacitor Bank Control

• M-6283A Three-Phase, Independent Phase Switching Digital Capacitor Bank Control

• Pole mount bracket (Figure 13)

NOTE: Refer to Figure 9 for referenced cabinet sensor and antenna locations.

• Load Current Sensor Options Include:

– 15 KV Fisher Pierce Line Post Sensor - Includes 35 ft. cable with 3-Pin Cannon connector(Figure 4) and Cabinet Side Connection.

– 15 KV Lindsey Line Post Sensor

– 30 Foot Cable for Lindsey Line Post Sensor

• Neutral Current Sensor Options Include:

▲ Caution: Use of a Fisher Pierce AT-929 for Neutral Current input to the M-6283A Control without Jumper JP1 placed in the A-B position will result in damage to the control and the display of an error code.

▲ CAUTION: Use of a Fisher Pierce AT-929 for Neutral Current input to the M-6280A control without a B-1391 Resistor Assembly installed between TB1-14 and TB1-15 will result in damage to the control and the display of an error code.

– 50:0.2 CT Neutral Current Sensor terminated with 3-Pin Cannon connector (Figure 4) using customer specified (10, 20, 35, or 45 foot) length of shielded twisted pair cable. Includes Cabinet Side Connections installed in hole location N.

– 50:0.2 CT Neutral Current Sensor with customer specified (10, 20, 35, or 45 foot) length of shielded twisted pair cable.

– Cannon Connector, cabinet side 3-Pin (Figure 4)

• Antenna Cable & Bulkhead Connector (For Installation with Antennas Mounting Direct to Cabinet) options include:

– TNC male to N female weatherproof bulkhead and antenna cable for lid mount.

– SMA male to N female weatherproof bulkhead and antenna cable for lid mount.

– SMA male to N female weatherproof bulkhead and antenna cable for cabinet mount.

– Double-D Hole for "N" connections in location 1, 2, 3 or 4 of cabinet to accommodate antenna exit.

• Lightning Protection (For installations with external antennas) options include:

– DSXL PolyPhaser Lightning Arrestor 700MHz - 2.7GHz N Female protected side, N Female Bulkhead antenna side.

– AL-LSXM PolyPhaser Lightning Arrestor 2 GHz to 6 GHz N Female protected side, N Female Bulkhead antenna side.

– SMA male to N male antenna cable to connect lightning protection to a radio for cabinet mount.

– TNC male to N male antenna cable to connect lightning protection to a radio for cabinet mount.

• Antennas:

– Laird FG9023, 902 MHz to 928 MHz, 3 dBi gain, fiberglass Omnidirectional antenna, N Female connector.

– FM2, antenna Pole Mount Bracket for Laird fiberglass antennas.

– Laird TRAB9023NP, 902 MHz to 928 MHz, 3 dBi gain, Omnidirectional Phantom antenna, N Female bulkhead connector.

– SMA male to N male antenna cable to connect antennas with an integrated bulkhead to a radio for cabinet mount.

– TNC male to N male antenna cable to connect antennas with an integrated bulkhead to a radio for cabinet mount.

–9–

M‑2980A Capacitor Control Cabinet

Optional Equipment/Accessories (Cont.’d)

• Radio Options Include:

2 Way VHF (154 MHz) radio

– Radius

2 Way (130 MHz - 3.7 GHz) radio modems:

– SilverSpring Networks SSN ebridge and sbridge

– MDS INET 900 AP

– MDS INET II

– MDS SD9

– MDS X710

– MDS SD4

– MDS 9810

– MDS TransNET

– MDS Mercury 3650 and 900

– MDS entraNET 900 and 2400

– CellNet Series III

Digital Cellular Modems:

– Sixnet BT series Mobility Pro/Industrial Pro Gateways

– Multitech Multimodem series routers and modems

– AirLink Raven II, X, XE

– Zywan 3G/GPRS/GSM Cellular Modem

• Radio ready options include:

– Universal Radio Bracket

– Universal Radio Bracket with 12 Vdc or 24 Vdc power supply

– Universal Radio Bracket with customer supplied power supply installed

• Radio, Factory Installation:

– Radio mounted and installed to M-2980A

– Customer supplied radio mounted and installed to M-2980A

• RS-232 Radio Comm Cable - 30" length. Connects M-6280A/M-6283A Control to radio’s DB9 Port

• Ethernet Radio Comm Cable - 24" length. Connects M-6280A/M-6283A Control to radio’s RJ45 Port

• Universal Power Cable provides fused 120 Vac to power a radio power supply (Included on all radio brackets)

• DB9 to DB25 - RS-232 Cable Converter

• Intrusion Detection Microswitch assembly

• 1/2" HEYCO Liquid Tight Cordgrip to secure cable coming into cabinet via hole location "T" or "B".

• Universal Radio/Modem Bracket (For field mounting in the door of the M-2980A Cabinet)

• 12 Vdc Power Supply for radio

• 24 Vdc Power Supply for radio

• 25 foot N male to N male LMR-400 antenna extension cable

M‑2980A Capacitor Control Cabinet

–10–

Optional Equipment/Accessories (Cont.’d) • Battery Backup Power

The Battery Backup option provides backup power to the control, and radio (if equipped). The Battery Backup system consists of:

– XP Power Model Number BCS75US13C

Input

Voltage: 90-264 Vac (120-370 Vdc)

Frequency: 47-63 Hz

Current: 75 W: 1.5/1.0 A max 115/230 Vac

Power Factor: Meets EN61000-3-2, Class A

Input Protection: Internal 4.0 A, 250 V fuse, fitted in line

Input Protection: External 6.3 A, 250 V fuse, fitted in line

Output Power

Output Power: 75 W

Output 1: 13.8 V, 5.50 A

Output 2: 13.8 V, 1.95 A

Efficiency: 86%

Environmental

Operating Temperature: -20 °C to +70 °C

Cooling: 75 W, Convection-cooled

Operating Humidity: 95% RH, non-condensing

Storage Temperature: -40 °C to +85 °C

Operating Altitude: 2000 m

Shock: 30 g pk, half sine, 6 axes

Vibration: 2 g rms, 10 Hz to 500 Hz, 10 min/cycle for 60 mins on each axis

Compliance

Emissions: EN55022, Level B conducted and radiated

Harmonic Currents: EN61000-3-2, class A

Voltage Flicker: EN61000-3-3

ESD Immunity: EN61000-4-2, level 3 Perf Criteria A

Radiated Immunity: EN61000-4-3, 3 V/m Perf Criteria A

EFT/Burst: EN61000-4-4, level 2 Perf Criteria A

Surge: EN61000-4-5, installation class 3, Perf Criteria A

Conducted Immunity: EN61000-4-6, 3 V Perf Criteria A

Dips & Interruptions: EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B

Safety Approvals: EN60950-1, UL60950-1

–11–

M‑2980A Capacitor Control Cabinet

Optional Equipment/Accessories (Cont.’d) – CYCLON® Battery BC Single Cell Model Number 0850-0108

Voltage: 12.0 Vdc

Capacity: 8.0 Ah

This product contains a non-spillable, sealed pure lead battery cell pack, which has been accepted by the Department of Transportation in compliance with tests found in 49 CFR §173.159(d). The rugged construction of the battery pack is rated for -65° C to +80° C (-85° F to +176° F) service environment. The battery pack is supplied in a charged condition capable of extremely high energy short circuit currents.

Required Storage Parameters to Maintain Charge CapacityDuring storage batteries lose charge capacity by self-discharge. The recommended recharge interval is every 6 months from date of receipt. To maintain charge capacity, check the charge every 6 months.

Temperature: 25° C

Humidity: Maximum relative humidity 80% for temperatures up to 31° C, decreasing to 31° C linearly to 50% relative humidity at 40° C.

Environment: Storage area to be free of dust, corrosive gases, flammable materials, dew, percolating water, rain and solar radiation.

M‑2980A Capacitor Control Cabinet

–12–

▲  CAUTION: Avoid short-circuiting terminals and wire terminals of opposite polarity.

L N(AC In) Gnd V0+ B+ B- N.C

CN1

CN2

Figure 5 Battery Backup Power Connections

Figure 6 Battery Backup Power Orientation in Cabinet

–13–

M‑2980A Capacitor Control Cabinet

Installation of Battery Cell PackThe optional Battery Cell Pack is shipped loose with the M-2980A cabinet. The following instructions describe the installation of the Battery Cell Pack.

▲ Caution: Observe all Cautions previously listed when installing the Battery Cell Pack.

▲ Caution: Do not short the Positive and Negative Terminals when installing the Battery Cell Pack. The Battery Cell Pack is capable of extremely high energy short circuit currents.

1. Install the Battery Cell Pack as shown in Figure 7, with the Negative Terminal towards the bottom of the cabinet door and the Positive Terminal towards the top of the cabinet door.

Figure 7 Battery Cell Pack Orientation

2. Fasten the restraining straps by threading the small end of the strap through the second slot of the other end of the strap (Figure 8), then pull tight (about 15 lbs). Thread the small end back through the same slot, this will keep it out of the way and make it easier to remove in the future.

Figure 8 Battery Cell Pack Restraining Straps

3. Connect the Negative marked White wire to the Battery Cell Negative Terminal and the Positive marked Red wire to the Battery Cell Positive Terminal.

M‑2980A Capacitor Control Cabinet

–14–

PhysicalPolycarbonate Cabinet

Size: 15.69" high x 13.19" wide x 7.27" deep (39.9 cm x 33.6 cm x 18.5 cm)

Approximate Weight: 9 lbs (4.1 kg)

Approximate Shipping Weight: 13 lbs, 5 oz (6.05 kg)

Approximate Weight with M-6280A/M-6283A Digital Capacitor Bank Control: 15 lbs, 5 oz (7.02 kg)

Approximate Shipping Weight with M-6280A/M-6283A Control: 23 lbs, 10 oz (10.61 kg)

Molded Lexan® Cabinet

Size: 18.38" high x 12.43" wide x 7.81" deep (46.7 cm x 31.6 cm x 19.84 cm)

Approximate Weight: 10 lbs, 8 oz (4.76 kg)

Approximate Shipping Weight: 12 lbs (5.44 kg)

Approximate Weight with M-6280A/M-6283A Digital Capacitor Bank Control: 18 lbs (8.17 kg)

Approximate Shipping Weight with M-6280A/M-6283A Control: 21 lbs, 8 oz (9.75 kg)

Cold Rolled Steel/Stainless Steel (304)B7B346

Size: 22.6" high x 11.38" wide x 10.09" deep (57.5 cm x 28.91 cm x 27.69 cm)

Approximate Weight: 16 lbs, 8 oz (7.48 kg)

Approximate Shipping Weight: 24 lbs (10.89 kg)

Approximate Weight with M-6280A/M-6283A Digital Capacitor Bank Control: 23 lbs, 8 oz (12.36 kg)

Approximate Shipping Weight with M-6280A/M-6283A Control: 36 lbs (16.33 kg)

NOTE: Add approximately 7.5 lbs (3.4 kg) when equipped with Battery Backup option.

WarrantyThe M-2980A Weatherproof Capacitor Control Cabinet is covered by a five year warranty from date of shipment. Third party mounted options will carry their respective manufacturer’s warranty, passed along through Beckwith Electric.

Specification subject to change without notice.

–15–

M‑2980A Capacitor Control Cabinet

TTOP

INTERFACE HOLE

1TOP LID

ANTENNA CABLE HOLE

2TOP CABINET

ANTENNA CABLE HOLE

BBOTTOM

INTERFACE HOLE

3BOTTOM LID

ANTENNA CABLE HOLE

4BOTTOM CABINET

ANTENNA CABLE HOLE

NNEUTRAL CURRENT

SENSOR HOLE

LLOAD CURRENTSENSOR HOLE

Figure 9 Cabinet Antenna Mounting and Sensor Location Options

M‑2980A Capacitor Control Cabinet

–16–

Polycarbonate Meter Socket Mount Cabinet

Lexan® Meter Socket Mount Cabinet

NonmetallicDoor Hinges Stainless Steel

Locking ClaspsAccept up to 3/8"

Hasp Locks

External Grounding Stud

4, 5 or 6 BladeMeter Socket(4 Standard)

Factory CustomWiring Available

C a b i n e t D o o r A c c o m o d a t e sOpt iona l Power Supp l ies andCommunication Devices

Integrated DoorHinge With StainlessSteel Hinge Pin

External Grounding Stud

Cabinet Door AccomodatesOptional Power Supplies andCommunication Devices

Radio AntennaMounting Hole

Radio AntennaMounting Hole

Radio AntennaMounting Hole

Stainless SteelLocking Clasps

Accept up to 3/8"Hasp Locks

4, 5 or 6 BladeMeter Socket(4 Standard)

Factory CustomWiring Available

Radio AntennaMounting Hole

Figure 10 Meter Socket Mount

–17–

M‑2980A Capacitor Control Cabinet

Polycarbonate Pole Mount Cabinet

Lexan® Pole Mount Cabinet

Adjustable Direct PoleMounting Bracket

Adjustable Direct PoleMounting Bracket

NonmetallicDoor Hinges

Stainless Steel LockingClasps Accept up to 3/8"Hasp Locks

External Grounding Stud

4, 5 or 6 Blade MeterSocket Plug(4 Standard)

Factory CustomWiring Available

Standard 5' Control Cable(Optional cable lengths in fivefoot increments up to 50 feet)

Cabinet Door AccomodatesOptional Power Suppl ies andCommunication Devices

Adjustable Direct PoleMounting Bracket

Integrated DoorHinge With Stainless

Steel Hinge Pin

External Grounding Stud

Standard 5' Control Cable(Optional cable lengths in fivefoot increments up to 50 feet)

Adjustable Direct PoleMounting Bracket

Stainless Steel LockingClasps Accept up to 3/8"Hasp Locks

4, 5 or 6 BladeMeter Socket Plug

(4 Standard)Factory CustomWiring Available

Cabinet Door AccomodatesOptional Power Suppl ies andCommunication Devices

Radio AntennaMounting Hole

Radio AntennaMounting Hole

Figure 11 Polycarbonate and Lexan Pole Mount Cabinet and Meter Socket Plug

M‑2980A Capacitor Control Cabinet

–18–

Cold Rolled Steel/Stainless SteelPole Mount Cabinet

Adjustable Direct PoleMounting Bracket

Adjustable Direct PoleMounting Bracket

Stainless SteelDoor Hinge

Stainless Steel LockingClasps Accept up to 3/8"Hasp Locks

External Grounding Stud

4, 5 or 6 Blade MeterSocket Plug(4 Standard)

Factory CustomWiring Available

Standard 5' Control Cable(Optional cable lengths in fivefoot increments up to 50 feet)

Cabinet AccomodatesOptional Power Suppliesand Communicat ionDevices

Figure 12 Cold Rolled Steel and Stainless Steel Pole Mount Cabinet and Meter Socket Plug

–19–

M‑2980A Capacitor Control Cabinet

558.822.00

398.5115.69

152.46.00

298

11.73

50820.00

16.63

5.56R.22

11.18R.44

25.41.00

76.23.00

11.1.44

38.11.50

11.18.44

76.23.00

335.0813.19

2.54.10

184.577.27

558.822.00

B-1225 Cable 5 PinConnector Shown, B1234Meter Base Adapter Cable

[Millimeters]

Figure 13 Polycarbonate Cabinet Dimensions

M‑2980A Capacitor Control Cabinet

–20–

7.80[19.8]

22.63[57.5]

18.38[46.7]

9.56[24.3]

12.43[31.6]

Meter Base MountShown for Reference

20.0[50.7]

21.63[54.9]

Figure 14 Lexan® Cabinet Dimensions

–21–

M‑2980A Capacitor Control Cabinet

3.70[9.4]

1.85[4.7]

R 0.56[1.42]

0.65[1.64]

CL

2.25[5.72]

1.13[2.87]

R 0.22[0.56]

2X Ø 0.53[1.53]

0.5[1.27]

1.50

22.63[57.5]

CL

R 0.27[0.69]

2X R 0.34[0.86]

2.75[6.99]

0.50[1.27]

0.67[1.7]

1.85[4.7]

10.09[27.69]

7.34[18.64]

0.50[1.27]

9.93[25.22]

9.88[25.01]

11.38[28.91]

17.52[44.5] 20.38

[51.77]

Figure 15 Cold Rolled Steel/Stainless Steel Cabinet Dimensions

© 2010 Beckwith Electric Co. All Rights Reserved.Printed in U.S.A. (1.15.03)

800‑2980A‑SP‑04MC1 02/17

BECKWITH ELECTRIC CO., INC.6190 - 118th Avenue North • Largo, Florida 33773-3724 U.S.A.

PHONE (727) 544-2326 • FAX (727) [email protected]