LPD - IMO · LPD 1102.02 en-GB, ID-No.: 901920001, 160-433/A 5 3. Technical Data 3.3 Sound level...

16
LPD 1102.02 en-GB, ID-No.: 901920001, 160-433/A Product Description LPD Std Line Flow volume: 2 - 20 l/min Max differential pressure: 10 bar Applications: Circulation and lubrication

Transcript of LPD - IMO · LPD 1102.02 en-GB, ID-No.: 901920001, 160-433/A 5 3. Technical Data 3.3 Sound level...

Page 1: LPD - IMO · LPD 1102.02 en-GB, ID-No.: 901920001, 160-433/A 5 3. Technical Data 3.3 Sound level Typical pump sound levels refer to free field conditions at a distance of 1 m from

LPD

110

2.02

en-

GB

, ID

-No.

: 901

9200

01, 1

60-4

33/A

Product Description

LPDStd Line

Flow volume: 2 - 20 l/minMax differential pressure: 10 barApplications: Circulation and lubrication

Page 2: LPD - IMO · LPD 1102.02 en-GB, ID-No.: 901920001, 160-433/A 5 3. Technical Data 3.3 Sound level Typical pump sound levels refer to free field conditions at a distance of 1 m from

LPD

110

2.02

en-

GB

, ID

-No.

: 901

9200

01, 1

60-4

33/A

www.imo.se2

1.1 Functionality

The LPD pumps are used for a number of different fluids:Lubrication oil, vegetable oil, hydraulic oil and other hydraulic fluids, polymers, emulsions and any non-aggressive fluid with sufficient lubricating properties.

1.2 Applications

Typical applications are:- Lubrication of machines such as diesel engines, gears etc - Supply and circulation of fuel oil for diesel engines, separators and burners

1.3 Installation

The pump is designed to be short coupled directly to an IEC 071 electric motor of flange type. By the angle bracket, the pump might be mounted horizontally or vertically.

As standard; the pump is supplied included counter flanges (IMO AB design).

For more information about installation, see the Installation and Start-up instruction for low pressure pumps.

1. Applications

Page 3: LPD - IMO · LPD 1102.02 en-GB, ID-No.: 901920001, 160-433/A 5 3. Technical Data 3.3 Sound level Typical pump sound levels refer to free field conditions at a distance of 1 m from

www.imo.se 3LPD

110

2.02

en-

GB

, ID

-No.

: 901

9200

01, 1

60-4

33/A

L P D 0 2 0 N 1 I V B P Pump series

LPD

SizePower rotor diameter [mm]015, 020

LeadN = Normal lead

GenerationDesign generation 1

Material in pump bodyI = Cast iron

Shaft seal designV = Carbon/Silicone Carbide seal with elastomers in Viton

MountingB = Flange mounting

ValveP = Internal pressure relief valve

Special designCode group omitted for standard design (A-number)

2. Pump model code

Page 4: LPD - IMO · LPD 1102.02 en-GB, ID-No.: 901920001, 160-433/A 5 3. Technical Data 3.3 Sound level Typical pump sound levels refer to free field conditions at a distance of 1 m from

LPD

110

2.02

en-

GB

, ID

-No.

: 901

9200

01, 1

60-4

33/A

www.imo.se4

3. Technical Data

3.1 Pressure Information

Pressure relief valve

The pump is equipped with an integral pressure relief valve with internal return, limiting the differen-tial pressure across the pump and protecting the pump.Should the discharge line be blocked, the relief valve will be opened by the pressure. The valve is adjustable for different opening pressures. The value of the pressure limit can be set at the factory and should be adjusted at installation (see Installation & Start-up instruction for low-pressure pumps).The maximum pressure accumulation is 3 bar.

The valve has a maximum set pressure of 10 bar.

Inlet pressure

Minimum inlet pressure (suction capability) is dependent on fluid viscosity and rotation speed. It in-creases with decreasing viscosity and decreasing speed. Information about minimum inlet pressure for each individual duty case can be obtained from IMO AB or pump selection software WinPump.

For size 015, maximum inlet pressure is 1 bar.For size 020, maximum inlet pressure is 5 bar.

For higher inlet pressure, kindly contact IMO AB.

Discharge pressure

For size 015, maximum discharge pressure is 11 bar.For size 020, maximum discharge pressure is 15 bar.

Differential pressure

Maximum differential pressure is 10 bar but reduced at low viscosities according to table belowViscosity [cSt] 1,4 2 6 10 >16Max. diff. pressure [bar] 3,4 4,0 6,5 8,3 10Refer to your IMO representative or use the pump selection software WinPump to determine the exact operating limits.

3.2 Driver information

Driver type

The pump is designed to be short-coupled to an electric motor with dimensions according to IEC size 71.The motor bearing will have to carry a slight axial load from the rotor set. With motors delivered from IMO AB, this load will not significantly impair the bearing life expectancy.

Speed

The maximum speed is 3600 rpm. For higher speeds, contact IMO AB.

Rotation

The pump is designed to operate in one rotational direction only, counter clockwise when facing the shaft end.For shorter periods of time, a few minutes for emptying a discharge line, the pump may be operated in reverse direction, provided the back pressure is limited to 3 bar.

Page 5: LPD - IMO · LPD 1102.02 en-GB, ID-No.: 901920001, 160-433/A 5 3. Technical Data 3.3 Sound level Typical pump sound levels refer to free field conditions at a distance of 1 m from

www.imo.se 5LPD

110

2.02

en-

GB

, ID

-No.

: 901

9200

01, 1

60-4

33/A

3. Technical Data

3.3 Sound level

Typical pump sound levels refer to free field conditions at a distance of 1 m from the pump. Noise of driver excluded in the quoted figures. The sound levels are measured at a discharge pressure of 5 bar, 2940 rpm and viscosity 40 cSt, according to ISO-3741. Size 015 020Sound level dB [A] 50 52

3.4 Moment of Inertia

Moment of intertia [10-6 kgm2]Size 015 020Value 5 10

3.5 Fluid viscosity

1,4 – 600 cSt.For higher viscosity, contact IMO AB.

3.6 Fluid temperature

-20 – +90 °C for all versions of LPD pumps.

Page 6: LPD - IMO · LPD 1102.02 en-GB, ID-No.: 901920001, 160-433/A 5 3. Technical Data 3.3 Sound level Typical pump sound levels refer to free field conditions at a distance of 1 m from

LPD

110

2.02

en-

GB

, ID

-No.

: 901

9200

01, 1

60-4

33/A

www.imo.se6

4. Design

4.1 Ball bearing

Ball bearing for the pump is not needed since the forces are handled by the ball bearing of the motor.

4.2 Material & design

Model Material pump Material rotor Material idler Material seal Material elastomer

LPD Cast iron Steel Cast iron Carbon/Silicon carbide

Viton

Page 7: LPD - IMO · LPD 1102.02 en-GB, ID-No.: 901920001, 160-433/A 5 3. Technical Data 3.3 Sound level Typical pump sound levels refer to free field conditions at a distance of 1 m from

www.imo.se 7LPD

110

2.02

en-

GB

, ID

-No.

: 901

9200

01, 1

60-4

33/A

015N 020N rpm l/min kW l/min kW 1470 2,2 0,1 5,3 0,2 1770 3,1 0,2 7,5 0,3 2950 6,7 0,3 16,0 0,5 3550 8,5 0,4 20,3 0,6

5. Performance GuideTypical performance values at 5 barFlow calculated at 26 cSt, power at 260 cSt. Pump performance established according to EN 14343.

0,0

0,3

0,6

0,9

1,2

1,5

0,0

5

10

15

20

25

020N015N

m3/h l/min

Page 8: LPD - IMO · LPD 1102.02 en-GB, ID-No.: 901920001, 160-433/A 5 3. Technical Data 3.3 Sound level Typical pump sound levels refer to free field conditions at a distance of 1 m from

LPD

110

2.02

en-

GB

, ID

-No.

: 901

9200

01, 1

60-4

33/A

www.imo.se8

6. Sectional view

Page 9: LPD - IMO · LPD 1102.02 en-GB, ID-No.: 901920001, 160-433/A 5 3. Technical Data 3.3 Sound level Typical pump sound levels refer to free field conditions at a distance of 1 m from

www.imo.se 9LPD

110

2.02

en-

GB

, ID

-No.

: 901

9200

01, 1

60-4

33/A

Pos

No

Den

omin

atio

n

1010

C

ompl

ete

pow

er ro

tor

(106

) S

haft

134

Lock

ing

scre

w16

2 S

haft

slee

ve20

1 Id

ler r

otor

401

Pum

p bo

dy45

3 S

crew

509

Sha

ft se

al51

4 R

etai

ning

ring

520

Fron

t cov

er52

1 O

-rin

g55

1 R

ear c

over

556

Gas

ket

Pos

No

Den

omin

atio

n

6000

C

ompl

ete

valv

e el

emen

t(6

05)

O-r

ing

(608

) Va

lve

spin

dle

(608

A)

Lock

ing

clam

p(6

08B)

S

crew

(608

C)

Pin

(612

0)

Com

plet

e re

gula

ting

nut

(613

) Te

nsio

n pi

n(6

14)

Valv

e pi

ston

(615

) Va

lve

sprin

g62

2 S

crew

623

Plat

e

7. List of Components

Dra

win

g re

mar

ks:

(1) B

end

win

gs o

f loc

king

cla

mp(

608)

ove

r sc

rew

s(60

8B)

Not

es:

- C

ompo

nent

s w

ith P

os N

o w

ithin

par

enth

esis

are

par

ts o

f sub

asse

mbl

y

Page 10: LPD - IMO · LPD 1102.02 en-GB, ID-No.: 901920001, 160-433/A 5 3. Technical Data 3.3 Sound level Typical pump sound levels refer to free field conditions at a distance of 1 m from

LPD

110

2.02

en-

GB

, ID

-No.

: 901

9200

01, 1

60-4

33/A

www.imo.se10

8. Pump Dimensions

Page 11: LPD - IMO · LPD 1102.02 en-GB, ID-No.: 901920001, 160-433/A 5 3. Technical Data 3.3 Sound level Typical pump sound levels refer to free field conditions at a distance of 1 m from

www.imo.se 11LPD

110

2.02

en-

GB

, ID

-No.

: 901

9200

01, 1

60-4

33/A

8. Pump Dimensions

Dra

win

g re

mar

ks:

(1) N

ame

plat

e(2

) Cov

er fo

r set

scr

ew. T

urn

set s

crew

clo

ckw

ise

to in

crea

se s

et p

ress

ure.

(3) O

utle

t. IS

O G

3/4”

(4) I

nlet

. IS

O G

1”

Not

es:

- D

imen

sion

s in

mm

Page 12: LPD - IMO · LPD 1102.02 en-GB, ID-No.: 901920001, 160-433/A 5 3. Technical Data 3.3 Sound level Typical pump sound levels refer to free field conditions at a distance of 1 m from

LPD

110

2.02

en-

GB

, ID

-No.

: 901

9200

01, 1

60-4

33/A

www.imo.se12

9. Pump Unit dimensions

Page 13: LPD - IMO · LPD 1102.02 en-GB, ID-No.: 901920001, 160-433/A 5 3. Technical Data 3.3 Sound level Typical pump sound levels refer to free field conditions at a distance of 1 m from

www.imo.se 13LPD

110

2.02

en-

GB

, ID

-No.

: 901

9200

01, 1

60-4

33/A

9. Pump Unit dimensions

Dra

win

g re

mar

ks

(1) C

over

for s

et s

crew

. Tur

n se

t scr

ew c

lock

wis

e to

in

crea

se s

et p

ress

ure

(2) S

pace

for d

ism

antli

ng(3

) Inl

et. I

SO

G1”

(4) O

utle

t. IS

O G

3/4”

*)

D

imen

sion

s an

d w

eigh

t are

app

roxi

mat

e va

lues

for

Bro

ok C

rom

pton

mot

ors

Not

es:

- D

imen

sion

s in

mm

Page 14: LPD - IMO · LPD 1102.02 en-GB, ID-No.: 901920001, 160-433/A 5 3. Technical Data 3.3 Sound level Typical pump sound levels refer to free field conditions at a distance of 1 m from

LPD

110

2.02

en-

GB

, ID

-No.

: 901

9200

01, 1

60-4

33/A

www.imo.se14

10. Accessories

11. Maintenance and Service

A bare shaft pump (Fig. 1) can be ordered with the accessories in fig. 2-3.

Fig. 1 Bare shaft pump Fig. 2 Connecting frame Fig. 3 Electric motor

Spare parts for these pumps are easily available from stock. For detailed information and know-how about service, see the Maintenance & Service Instruction for LPD pumps or contact IMO AB.

Page 15: LPD - IMO · LPD 1102.02 en-GB, ID-No.: 901920001, 160-433/A 5 3. Technical Data 3.3 Sound level Typical pump sound levels refer to free field conditions at a distance of 1 m from

www.imo.se 15LPD

110

2.02

en-

GB

, ID

-No.

: 901

9200

01, 1

60-4

33/A

Page 16: LPD - IMO · LPD 1102.02 en-GB, ID-No.: 901920001, 160-433/A 5 3. Technical Data 3.3 Sound level Typical pump sound levels refer to free field conditions at a distance of 1 m from

LPD

110

2.02

en-

GB

, ID

-No.

: 901

9200

01, 1

60-4

33/A

Adress:

IMO ABPO Box 42090, 126 14 Stockholm