Lowara-1315-submersible-pump-Lenntech1 Vortex 1.1 Product description Usage A submersible pump, with...

15
Technical Specification 1315, 60Hz Lenntech Tel. +31-152-610-900 Fax. +31-152-616-289 info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289

Transcript of Lowara-1315-submersible-pump-Lenntech1 Vortex 1.1 Product description Usage A submersible pump, with...

Page 1: Lowara-1315-submersible-pump-Lenntech1 Vortex 1.1 Product description Usage A submersible pump, with vortex hydraulic, for liquids containing solids and abrasive media, or light wastewater.

Technical Specification

1315, 60Hz

[email protected] Tel. +31-152-610-900www.lenntech.com Fax. [email protected] Tel. +31-152-610-900www.lenntech.com Fax. +31-152-616-289

Page 2: Lowara-1315-submersible-pump-Lenntech1 Vortex 1.1 Product description Usage A submersible pump, with vortex hydraulic, for liquids containing solids and abrasive media, or light wastewater.

Table of Contents

1 Vortex........................................................................................................................................... 21.1 Product description............................................................................................................. 21.2 Motor rating and performance curves.............................................................................. 4

2 Non-clog...................................................................................................................................... 82.1 Product description............................................................................................................. 82.2 Motor rating and performance curves............................................................................ 10

Table of Contents

1315, 60Hz Technical Specification 1

Page 3: Lowara-1315-submersible-pump-Lenntech1 Vortex 1.1 Product description Usage A submersible pump, with vortex hydraulic, for liquids containing solids and abrasive media, or light wastewater.

1 Vortex1.1 Product description

Usage

A submersible pump, with vortex hydraulic, for liquids containing solids and abrasivemedia, or light wastewater.

Denomination

Type Non-explosion proofversion

Explosion proofversion

Model variant Installation types

Vortex 1315.181 1315.090 • H – High head• M – Medium

head

• Free-standing• Wet-well

The pump can be used in the following installations:

Free-standing Portable semipermanent, wet well arrangement with hose coupling orflange for connection to the discharge pipeline.

Wet-well Semipermanent, wet well arrangement with the pump installed on twoguide bars. The connection to the discharge is automatic.

Application limits

Feature Description

Liquid temperature Maximum 40°C (104°F)

Depth of immersion Maximum 20 m (65 ft)

pH of the pumped liquid 5.5 – 14

Liquid density Maximum 1100 kg/m3

Motor data

Feature Description

Motor type Squirrel-cage induction motor

Frequency 60 Hz

1 Vortex

2 1315, 60Hz Technical Specification

Page 4: Lowara-1315-submersible-pump-Lenntech1 Vortex 1.1 Product description Usage A submersible pump, with vortex hydraulic, for liquids containing solids and abrasive media, or light wastewater.

Feature Description

Power supply 1-phase or 3-phase

Starting method • Direct on-line• Star-delta• Variable Frequency Drive (VFD)

Number of starts per hour Maximum 15

Code compliance IEC 60034-1

Voltage variation withoutoverheating

±10%, if it does not run continuously at full load

Voltage imbalance betweenphases

Maximum 2%

Stator insulation class F (155°C [311°F])

Cables

Application Type

Direct-on-line start or Y/D start with two cables Flygt SUBCAB® - a heavy duty 4 cores motor power cablewith two twisted pair screened control cores. Conductorinsulation rating of 90°C, which allows for increasedcurrent. Superior mechanical strength and high abrasionand tear resistant. Chemical resistant within pH 3-10 andozone, oil, and flame resistant. Used up to 70°C watertemperature. Cables < 10 mm2 with unscreened controlcores.

Y/D start Flygt SUBCAB® - a heavy duty 7 cores motor power cablewith two twisted pair screened control cores. Conductorinsulation rating of 90°C, which allows for increasedcurrent. Superior mechanical strength and high abrasionand tear resistant. Chemical resistant within pH 3-10 andozone, oil, and flame resistant. Used up to 70°C watertemperature. Cables < 7G6 mm2 with unscreenedcontrol cores.

Monitoring equipment

Motor Thermal contacts opening temperature

15-12-2Z, 15-12-4Z 140°C (284°F)

Materials

Table 1: Major parts except mechanical seals

Denomination Material ASTM EN

Major castings Cast iron, gray 30B GJL-200

Pump housing Cast iron, gray 30B GJL-200

Impeller, alternative 1 Cast iron, gray 35B GJL-250

Impeller, alternative 2 Cast iron, gray 30B GJL-200

Lifting eye bolt Steel electro zinc coated – EN 10084 - C15E

Lifting handle Stainless steel AISI 304 1,4301

Shaft Stainless steel AISI 431 1.4057+QT800

Screws and nuts Stainless steel, A2 AISI 304 1.4301, 1.4306, 1.4307,1.4311

O-rings Nitrile rubber (NBR) 70° IRH – –

Oil, part no 901752 Medical white oil of paraffintype. Fulfills FDA 172.878 (a)

– –

1 Vortex

1315, 60Hz Technical Specification 3

Page 5: Lowara-1315-submersible-pump-Lenntech1 Vortex 1.1 Product description Usage A submersible pump, with vortex hydraulic, for liquids containing solids and abrasive media, or light wastewater.

Table 2: Mechanical seals

Inner seal Outer seal

Carbon (CSb)/ Aluminum oxide (Al2O3) Corrosion resistant cemented carbide (WCCR)/ Aluminumoxide (Al2O3)/

Surface treatment

Finish

Black or blue two-component high-solid top coating. See internal standard M 0700.00.0004 for standard painting.

Options

• Leakage sensor in the stator housing (FLS)

Accessories

• Installation equipment

Sold in kits• Mechanical accessories such as discharge connections, adapters, and hose

connections• Electrical accessories such as pump controller, control panels, starters, monitoring

relays, and cables

1.2 Motor rating and performance curvesThese are examples of motor rating and curves. For more information, please contactyour local sales and service representative.

Star-delta starting current is 1/3 of Direct on-line starting current.

H

Q [l/s] / [usgpm]

H [ft] / [m]

2P [hp] / [kW]

0 4 8 12 16 20

0 50 100 150 200 250 300 350

0

2

4

6

8

10

12

14

16

18

0

10

20

30

40

50

60

2

3

4

5

2

4

6

8

H

295

295

296

296

297

297

WS010601A

1 Vortex

4 1315, 60Hz Technical Specification

Page 6: Lowara-1315-submersible-pump-Lenntech1 Vortex 1.1 Product description Usage A submersible pump, with vortex hydraulic, for liquids containing solids and abrasive media, or light wastewater.

Table 3: 460 V, 60 Hz, 3–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

RatedCurrent, A

Start current,A

Power Factor,cos φ

Installation

4.8 6.4 295 3465 7.7 53 0.91 FS, WW

4.1 5.5 296 3490 6.7 53 0.9 FS, WW

3.5 4.7 297 3505 5.8 53 0.87 FS, WW

• FS= Free-standing• WW=Wet-well

Q [l/s] / [usgpm]

H [ft] / [m]

2P [hp] / [kW]

0 4 8 12 16 20

0 50 100 150 200 250 300 350

0

2

4

6

8

10

12

14

16

0

10

20

30

40

50

2

3

4

5

2

4

6

8

H

296

296

297

297

WS010600A

Table 4: 230 V, 60 Hz, 1–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

RatedCurrent, A

Start current,A

Power Factor,cos φ

Installation

4.1 5.5 296 3475 22 96 1 FS, WW

3.5 4.7 297 3500 19 96 1 FS, WW

• FS= Free-standing• WW=Wet-well

1 Vortex

1315, 60Hz Technical Specification 5

Page 7: Lowara-1315-submersible-pump-Lenntech1 Vortex 1.1 Product description Usage A submersible pump, with vortex hydraulic, for liquids containing solids and abrasive media, or light wastewater.

M

Q [l/s] / [usgpm]

H [ft] / [m]

2P [hp] / [kW]

0 5 10 15 20 25 30 35 40

0 100 200 300 400 500 600 700

0

2

4

6

8

10

12

0

5

10

15

20

25

30

35

40

45

1.52.02.53.03.54.0

2

3

4

5

6

M

483

483

485

485

485

485

487

487

487

487

WS010599A

Table 5: 460 V, 60 Hz, 3–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

RatedCurrent, A

Start current,A

Power Factor,cos φ

Installation

3.7 5 483 1695 6.9 34 0.85 FS, WW

2.5 3.4 487 1735 5.0 34 0.77 FS, WW

3 4 485 1720 5.6 34 0.81 FS, WW

• FS= Free-standing• WW=Wet-well

1 Vortex

6 1315, 60Hz Technical Specification

Page 8: Lowara-1315-submersible-pump-Lenntech1 Vortex 1.1 Product description Usage A submersible pump, with vortex hydraulic, for liquids containing solids and abrasive media, or light wastewater.

Q [l/s] / [usgpm]

H [ft] / [m]

2P [hp] / [kW]

0 5 10 15 20 25 30 35 40

0 100 200 300 400 500 600 700

0

2

4

6

8

10

0

5

10

15

20

25

30

35

1.5

2.0

2.5

3.0

3.5

2

3

4

5

M

485

485

485

485

487

487

487

487

WS010598A

Table 6: 230 V, 60 Hz, 1–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

RatedCurrent, A

Start current,A

Power Factor,cos φ

Installation

2.5 3.4 487 1765 14 77 0.98 FS, WW

3 4 485 1755 17 77 0.98 FS, WW

• FS= Free-standing• WW=Wet-well

1 Vortex

1315, 60Hz Technical Specification 7

Page 9: Lowara-1315-submersible-pump-Lenntech1 Vortex 1.1 Product description Usage A submersible pump, with vortex hydraulic, for liquids containing solids and abrasive media, or light wastewater.

2 Non-clog2.1 Product description

Usage

A submersible pump for efficient pumping of clean water, surface water, and wastewatercontaining solids. The pump is designed for sustained efficiency over time.

Denomination

Type Non-explosion proofversion

Explosion proofversion

Model variant Installation types

Non-clog 1315.181 1315.090 • M – Mediumhead

• S – Super highhead

• Free-standing• Wet-well

The pump can be used in the following installations:

Free-standing Portable semipermanent, wet well arrangement with hose coupling orflange for connection to the discharge pipeline.

Wet-well Semipermanent, wet well arrangement with the pump installed on twoguide bars. The connection to the discharge is automatic.

Application limits

Feature Description

Liquid temperature Maximum 40°C (104°F)

Depth of immersion Maximum 20 m (65 ft)

pH of the pumped liquid 5.5 – 14

Liquid density Maximum 1100 kg/m3

Motor data

Feature Description

Motor type Squirrel-cage induction motor

Frequency 60 Hz

2 Non-clog

8 1315, 60Hz Technical Specification

Page 10: Lowara-1315-submersible-pump-Lenntech1 Vortex 1.1 Product description Usage A submersible pump, with vortex hydraulic, for liquids containing solids and abrasive media, or light wastewater.

Feature Description

Power supply 1-phase or 3-phase

Starting method • Direct on-line• Star-delta• Variable Frequency Drive (VFD)

Number of starts per hour Maximum 15

Code compliance IEC 60034-1

Voltage variation withoutoverheating

±10%, if it does not run continuously at full load

Voltage imbalance betweenphases

Maximum 2%

Stator insulation class F (155°C [311°F])

Cables

Application Type

Direct-on-line start or Y/D start with two cables Flygt SUBCAB® - a heavy duty 4 cores motor power cablewith two twisted pair screened control cores. Conductorinsulation rating of 90°C, which allows for increasedcurrent. Superior mechanical strength and high abrasionand tear resistant. Chemical resistant within pH 3-10 andozone, oil, and flame resistant. Used up to 70°C watertemperature. Cables < 10 mm2 with unscreened controlcores.

Y/D start Flygt SUBCAB® - a heavy duty 7 cores motor power cablewith two twisted pair screened control cores. Conductorinsulation rating of 90°C, which allows for increasedcurrent. Superior mechanical strength and high abrasionand tear resistant. Chemical resistant within pH 3-10 andozone, oil, and flame resistant. Used up to 70°C watertemperature. Cables < 7G6 mm2 with unscreenedcontrol cores.

Monitoring equipment

Motor Thermal contacts opening temperature

15-12-2Z, 15-12-4Z 140°C (284°F)

Materials

Table 7: Major parts except mechanical seals

Denomination Material ASTM EN

Major castings Cast iron, gray 30B GJL-200

Pump housing Cast iron, gray 30B GJL-200

Impeller Cast iron, gray 30B GJL-200

Lifting eye bolt Steel electro zinc coated – EN 10084 - C15E

Lifting handle Stainless steel AISI 304 1,4301

Shaft Stainless steel AISI 431 1.4057+QT800

Screws and nuts Stainless steel, A2 AISI 304 1.4301, 1.4306, 1.4307,1.4311

O-rings Nitrile rubber (NBR) 70° IRH – –

Oil, part no 901752 Medical white oil of paraffintype. Fulfills FDA 172.878 (a)

– –

2 Non-clog

1315, 60Hz Technical Specification 9

Page 11: Lowara-1315-submersible-pump-Lenntech1 Vortex 1.1 Product description Usage A submersible pump, with vortex hydraulic, for liquids containing solids and abrasive media, or light wastewater.

Table 8: Mechanical seals

Inner seal Outer seal

Carbon (CSb)/ Aluminum oxide (Al2O3) Corrosion resistant cemented carbide (WCCR)/ Aluminumoxide (Al2O3)/

Surface treatment

Finish

Black or blue two-component high-solid top coating. See internal standard M 0700.00.0004 for standard painting.

Options

• Leakage sensor in the stator housing (FLS)

Accessories

• Installation equipment

Sold in kits• Mechanical accessories such as discharge connections, adapters, and hose

connections• Electrical accessories such as pump controller, control panels, starters, monitoring

relays, and cables

2.2 Motor rating and performance curvesThese are examples of motor rating and curves. For more information, please contactyour local sales and service representative.

Star-delta starting current is 1/3 of Direct on-line starting current.

M

Q [l/s] / [usgpm]

H [ft] / [m]

2P [hp] / [kW]

0 10 20 30 40 50

0 100 200 300 400 500 600 700 800 900

0

2

4

6

8

10

12

14

0

10

20

30

40

50

2

3

4

2

3

4

5

6

M

422

422

423

423

424

424

425

425

432

432

433

433

434

434

435

435

WS010593A

2 Non-clog

10 1315, 60Hz Technical Specification

Page 12: Lowara-1315-submersible-pump-Lenntech1 Vortex 1.1 Product description Usage A submersible pump, with vortex hydraulic, for liquids containing solids and abrasive media, or light wastewater.

Table 9: 460 V, 60 Hz, 3–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

RatedCurrent, A

Start current,A

Power Factor,cos φ

Installation

3.7 5 422 1695 6.9 34 0.85 FS, WW

3.7 5 432 1695 6.9 34 0.85 FS, WW

2.5 3.4 424 1735 5.0 34 0.77 FS, WW

2.5 3.4 425 1735 5.0 34 0.77 FS, WW

2.5 3.4 435 1735 5.0 34 0.77 FS, WW

3 4 423 1720 5.6 34 0.81 FS, WW

3 4 433 1720 5.6 34 0.81 FS, WW

3 4 434 1720 5.6 34 0.81 FS, WW

• FS= Free-standing• WW=Wet-well

Q [l/s] / [usgpm]

H [ft] / [m]

2P [hp] / [kW]

0 10 20 30 40 50

0 100 200 300 400 500 600 700 800 900

0

2

4

6

8

10

0

5

10

15

20

25

30

35

1.5

2.0

2.5

3.0

2

3

4

M

424

424

425

425

434

434

435

435

WS010592A

Table 10: 230 V, 60 Hz, 1–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

RatedCurrent, A

Start current,A

Power Factor,cos φ

Installation

2.5 3.4 425 1765 14 77 0.98 FS, WW

2.5 3.4 435 1765 14 77 0.98 FS, WW

3 4 424 1755 17 77 0.98 FS, WW

3 4 434 1755 17 77 0.98 FS, WW

• FS= Free-standing• WW=Wet-well

2 Non-clog

1315, 60Hz Technical Specification 11

Page 13: Lowara-1315-submersible-pump-Lenntech1 Vortex 1.1 Product description Usage A submersible pump, with vortex hydraulic, for liquids containing solids and abrasive media, or light wastewater.

S

Q [l/s] / [usgpm]

H [ft] / [m]

2P [hp] / [kW]

0 5 10 15 20 25 30

0 100 200 300 400 500

0

5

10

15

20

25

30

0

20

40

60

80

100

3

4

5

3

4

5

6

7

8

S

263

263

264

264

265

265

273

273

274

274

275

275

WS010595A

Table 11: 460 V, 60 Hz, 3–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

RatedCurrent, A

Start current,A

Power Factor,cos φ

Installation

4.8 6.4 263 3465 7.7 53 0.91 FS, WW

4.8 6.4 273 3465 7.7 53 0.91 FS, WW

4.1 5.5 264 3490 6.7 53 0.9 FS, WW

4.1 5.5 274 3490 6.7 53 0.9 FS, WW

3.5 4.7 265 3505 5.8 53 0.87 FS, WW

3.5 4.7 275 3505 5.8 53 0.87 FS, WW

• FS= Free-standing• WW=Wet-well

2 Non-clog

12 1315, 60Hz Technical Specification

Page 14: Lowara-1315-submersible-pump-Lenntech1 Vortex 1.1 Product description Usage A submersible pump, with vortex hydraulic, for liquids containing solids and abrasive media, or light wastewater.

Q [l/s] / [usgpm]

H [ft] / [m]

2P [hp] / [kW]

0 5 10 15 20 25

0 50 100 150 200 250 300 350 400 450

0

5

10

15

20

25

0

10

20

30

40

50

60

70

80

90

2.5

3.0

3.5

4.0

4.5

3

4

5

6

S

264

264

265

265

274

274

275

275

WS010594A

Table 12: 230 V, 60 Hz, 1–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

RatedCurrent, A

Start current,A

Power Factor,cos φ

Installation

4.1 5.5 264 3475 22 96 1 FS, WW

4.1 5.5 274 3475 22 96 1 FS, WW

3.5 4.7 265 3500 19 96 1 FS, WW

3.5 4.7 275 3500 19 96 1 FS, WW

• FS= Free-standing• WW=Wet-well

2 Non-clog

1315, 60Hz Technical Specification 13

Page 15: Lowara-1315-submersible-pump-Lenntech1 Vortex 1.1 Product description Usage A submersible pump, with vortex hydraulic, for liquids containing solids and abrasive media, or light wastewater.

Xylem |’zīləm|

1) The tissue in plants that brings water upward from the roots;2) a leading global water technology company.

We’re a global team unified in a common purpose: creating advancedtechnology solutions to the world’s water challenges. Developing newtechnologies that will improve the way water is used, conserved, and re-used inthe future is central to our work. Our products and services move, treat, analyze,monitor and return water to the environment, in public utility, industrial,residential and commercial building services settings. Xylem also provides aleading portfolio of smart metering, network technologies and advancedanalytics solutions for water, electric and gas utilities. In more than 150 countries,we have strong, long-standing relationships with customers who know us for ourpowerful combination of leading product brands and applications expertise witha strong focus on developing comprehensive, sustainable solutions.

Visit our Web site for the latest version of this documentand more information

The original instruction is in English. All non-Englishinstructions are translations of the original instruction.

© 2018 Xylem Inc

887506_1.0_en-US_2018-05_TS_1315, 60Hz

[email protected] Tel. +31-152-610-900www.lenntech.com Fax. [email protected] Tel. +31-152-610-900www.lenntech.com Fax. +31-152-616-289