LOW VOLTAGE DISCONNECT Instructions Scan for additional...

2
CAUTION symbol refers to a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. WARNING symbol refers to a potentially hazardous situation which, if not avoided, may result in death or serious injury. Instructions PN 7635 / 7635B Blue Sea Systems Inc. p 360.738.8230 4600 Ryzex Way f 360.734.4195 Bellingham, WA 98226 USA www.bluesea.com 980016770 Rev.003 WARNING CAUTION Installation GUARANTEE: Blue Sea Systems stands behind its products for as long as you own them. Find detailed information at www.bluesea.com/about. For customer service, call 800-222-7617. Senses low battery voltage and automatically disconnects devices to save power for starting or to preserve battery life Status light in both m-LVD and Remote Control Switch provides visual warning of low voltage state prior to disconnect Alarm output available for audible warning of low voltage state prior to disconnect (optional alarm required) Remote Control Switch Functions: Disconnect Voltage Adjustment - Sets desired disconnect voltage Override - Temporarily delays circuit disconnect for 10 minutes OFF - Temporarily disconnects circuits until voltage rises Override or OFF - Silences alarm (optional alarm required) Includes Remote Control Switch PN 7928 DC AC Before beginning electrical installation, disconnect all AC and DC power sources. Do not service equipment that has been automatically disconnected by the m-LVD without first permanently removing power from the equipment by a means other than the m-LVD. WARNING CAUTION If you are not knowledgeable about electrical systems, consult an electrical professional. Mount the m-LVD. Three mounting options are illustrated below: 1.00" (25.4mm) SUGGESTED MINIMUM SCREW LENGTH #10 SCREWS WITH THREAD APPROPRIATE FOR MOUNTING SURFACE 2-5/8" (66.7mm) MOUNTING HOLE DIAMETER 5/16" (7.9mm) MAXIMUM PANEL THICKNESS 2-5/16" (58.7mm) MOUNTING HOLE DIAMETER 1.00" (25.4mm) SUGGESTED SCREW LENGTH FOR 1/8" PANEL THICKNESS #10 HEX NUTS 3/8" WIDTH #10 MACHINE SCREWS 2.25 (57.2mm) SUGGESTED MINIMUM SCREW LENGTH #10 SCREWS WITH THREAD APPROPRIATE FOR MOUNTING SURFACE Rear Panel Mount Front Panel Mount Surface Mount Front Panel Mount (Rear View) m -LVD LOW VOLTAGE DISCONNECT Scan for additional product information 1.45" (36.83mm) 0.83" (21.08mm) Remote Control Switch Mounting Hole Dimensions Intermittent Rating: 5 min. 115A Continuous Rating 65A Nominal Voltage 12V DC Cable Size (to meet current ratings) 6 AWG (16mm²) Terminal Stud Size 1/4"-20 (M6) Disconnect Voltage 11.3V12.1V Adjustable Factory Default Disconnect Voltage 12.1V Time Delay to Alarm The unit waits 5 mins after the voltage goes below the set point before it starts the warning. Then an additional 5 mins to disconnect, 10 mins total. Alarm Time Before Disconnect 5 mins Reconnect Voltage 13V DC Remote Control Switch Type: SPDT, Action: (ON)-OFF-(ON) ( ) = momentary Maximum Alarm Current 250mA Maximum External LED Current 14mA Regulatory ISO 8846, Meets SAE J1171 external ignition protection requirements Specifications Installation (continued) Remove rear insulating cover as illustrated.

Transcript of LOW VOLTAGE DISCONNECT Instructions Scan for additional...

Page 1: LOW VOLTAGE DISCONNECT Instructions Scan for additional ...assets.bluesea.com/files/resources/instructions/980016770.pdf · Instructions PN 7635 / 7635B Blue Sea Systems Inc. p 360.738.8230

CAUTION symbol refers to a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.

WARNING symbol refers to a potentially hazardous situation which, if not avoided, may result in death or serious injury.

InstructionsPN 7635 / 7635B

Blue Sea Systems Inc. p 360.738.82304600 Ryzex Way f 360.734.4195Bellingham, WA 98226 USA www.bluesea.com

980016770 Rev.003

WARNING

CAUTION

Installation

GUARANTEE: Blue Sea Systems stands behind its products for as long as you own them. Find detailed information at www.bluesea.com/about. For customer service, call 800-222-7617.

Senses low battery voltage and automatically disconnects devices to save power for starting or to preserve battery life• Status light in both m-LVD and Remote Control Switch provides visual warning of low voltage state prior to disconnect• Alarm output available for audible warning of low voltage state prior to disconnect (optional alarm required) • Remote Control Switch Functions: Disconnect Voltage Adjustment - Sets desired disconnect voltage Override - Temporarily delays circuit disconnect for 10 minutes OFF - Temporarily disconnects circuits until voltage rises Override or OFF - Silences alarm (optional alarm required)• Includes Remote Control Switch PN 7928

DC AC

Before beginning electrical installation, disconnect all AC and DC power sources. Do not service equipment that has been automatically disconnected by the m-LVD

withoutfirstpermanentlyremovingpowerfromtheequipmentbyameansother than the m-LVD.

WARNING

CAUTION If you are not knowledgeable about electrical systems, consult an electrical professional.

Mount the m-LVD. Three mounting options are illustrated below:

1.00" (25.4mm)SUGGESTED

MINIMUM SCREWLENGTH

#10 SCREWSWITH THREADAPPROPRIATE

FOR MOUNTINGSURFACE

2-5/8" (66.7mm)MOUNTING HOLE

DIAMETER

5/16" (7.9mm)MAXIMUM PANEL

THICKNESS

2-5/16" (58.7mm)MOUNTING HOLE

DIAMETER

1.00" (25.4mm)SUGGESTED SCREW

LENGTH FOR 1/8"PANEL THICKNESS

#10 HEX NUTS3/8" WIDTH

#10 MACHINESCREWS

2.25 (57.2mm)SUGGESTED MINIMUM

SCREW LENGTH

#10 SCREWSWITH THREADAPPROPRIATE

FOR MOUNTINGSURFACE

Rear Panel Mount

Front Panel Mount

Surface Mount

Front Panel Mount (Rear View)

m-LVD LOW VOLTAGE DISCONNECT

Scan for additionalproduct information

1.45" (36.83mm)

0.83" (21.08mm)

Remote Control SwitchMounting Hole Dimensions

Intermittent Rating: 5 min. 115AContinuous Rating 65ANominal Voltage 12V DCCable Size (to meet current ratings) 6 AWG (16mm²)Terminal Stud Size 1/4"-20 (M6)Disconnect Voltage 11.3V–12.1V AdjustableFactory Default Disconnect Voltage 12.1VTime Delay to Alarm The unit waits 5 mins after the voltage goes below the set point before it starts the warning. Then an additional 5 mins to disconnect, 10 mins total.Alarm Time Before Disconnect 5 minsReconnect Voltage 13V DCRemote Control Switch Type: SPDT, Action: (ON)-OFF-(ON) ( ) = momentaryMaximum Alarm Current 250mAMaximum External LED Current 14mARegulatoryISO 8846, Meets SAE J1171 external ignition protection requirements

Specifications

Installation (continued)

Remove rear insulating cover as illustrated.

Page 2: LOW VOLTAGE DISCONNECT Instructions Scan for additional ...assets.bluesea.com/files/resources/instructions/980016770.pdf · Instructions PN 7635 / 7635B Blue Sea Systems Inc. p 360.738.8230

Installation Diagram

COMMON BUSBAR

REMOTE CONTROLSWITCH

OPTIONAL ALARM STEREO OR OTHER

12V DC DEVICES

BATTERY

LED OUTPUT

OPTIONAL BATTERY SWITCH Required if

the battery is over 800 Cold

Cranking Amps (CCA)

ALARM OUTPUT

1

2

3

8 74

5

610A FUSE

FUSE*See Wire Size

and Fuse Rating Chart

above

FUSE

Connection Legend

DC Positive

DC Negative (Ground)OptionalControl

+

-NEG

POS

FUSE

m-LVD Connections FunctionA BatteryB Load1 Ground2 Remote Switch3 Alarm Output4 LED Output

• The Installation Diagram illustrated below represents a common installation and is not meant to be a guide for wiring a specific vessel. Caution: Disconnect battery connections before beginning the installation. Reconnect after the installation is complete. Use the wire sizing chart below to select the appropriate wire sizes. Consult an ABYC certified electrician for proper fuse placement and sizing.

* Larger wire sizes may be required to minimize voltage drop in long wire runs. For more information please use the Circuit Wizard at www.circuitwizard.bluesea.com.

Wire Size and Fuse Rating Chart*Amps Min. Wire Size* (AWG) Fuse Rating Min. Wire Size* (Metric)≤30 #10 40A-50A 6 mm²≤50 #8 60A-65A 10 mm²≤65 #6 90A-100A 16 mm²

Electrical Connections

m-LVD Connection Table

Disconnect Voltage Adjustment

Disconnect Voltage LED Flash CountFactory Default:

12.1V 5

11.9V 411.7V 311.5V 211.3V 1

• Press and hold the OVERRIDE position of the remote control switch for 10 seconds to enter adjustment mode. Adjustment mode can only be entered in the Connected or Disconnected states, not in the Low Voltage Warning state. LED will beginaflashpatterntoindicatethecurrentDisconnect voltage setting (see table below).

Disconnect Voltage Adjustment Table

• Press and release OFF to decrease the Disconnect voltagesettingin0.2Vincrementsdowntoaminimumof11.3V(1flash).

• Press and release OVERRIDE to increase the Disconnect voltagein0.2Vincrementsuptoamaximumof12.1V(5flashes).

• Whenyouaresatisfiedwithyourselection,releasethe switch, and wait approximately 20 seconds, the m-LVD will save the new Disconnect Voltage Setting, and automatically return to normal operation.

m-LVD Normal Operation Status Chart

LED Alarm Relay StatusOFF Solid OFF Closed ConnectedON Solid ON Closed Low Voltage WarningDouble Flash OFF Open Disconnected

m-LVD Normal Operation Status Chart

Operation during Low Voltage Warning or when Disconnected• Press OVERRIDE to temporarily delay circuit disconnect for 10 minutes.• Press OVERRIDE or OFF to silence alarm (optional alarm required).• Press OFF to temporarily disconnect circuits until voltage rises.

Remote Control Switch