LOW COST ELECTRICITY METER READING SYSTEM
USING GSM
PRESENTED BY
JEFF JOSEPH
ROLL NO:26
S7,EEE
![Page 2: Low cost ppt final](https://reader036.fdocuments.us/reader036/viewer/2022062400/58d071dc1a28abc9788b51f9/html5/thumbnails/2.jpg)
2
Preview
Introduction Existing system It’s Disadvantages Requirement of proposed system Hardware Implementation Software Implementation Results Advantages Conclusion References
![Page 3: Low cost ppt final](https://reader036.fdocuments.us/reader036/viewer/2022062400/58d071dc1a28abc9788b51f9/html5/thumbnails/3.jpg)
Introduction
Total electricity demand in India 2015-2016 is 1,162,423 MU but available is 1,138,346 MU
Metering-one of the most imp. steps in transmission and usage of electricity.
Most of the meters are of digital meters working with human interventions
The proposed system-working of energy meter without human interventions, less power consumption
GSM module-for communication & microcontroller MSP430FG4618
3
![Page 4: Low cost ppt final](https://reader036.fdocuments.us/reader036/viewer/2022062400/58d071dc1a28abc9788b51f9/html5/thumbnails/4.jpg)
4
Two types of energy meters are commonly used Mechanical energy meter & Electronic energy meter
Existing system
![Page 5: Low cost ppt final](https://reader036.fdocuments.us/reader036/viewer/2022062400/58d071dc1a28abc9788b51f9/html5/thumbnails/5.jpg)
Existing system (Cont...)
Mechanical energy meter work - principle of electromagnetic induction, metallic disc acted upon- two coils
Primary and secondary coils produce magnetic flux in proportional to voltage and current respectively
Field due to voltage-lagg by 90 degree results eddy current, exert a force on the disc
Disc attached to a spindle-worm gear registers This drives the register where the readings are noted
5
![Page 6: Low cost ppt final](https://reader036.fdocuments.us/reader036/viewer/2022062400/58d071dc1a28abc9788b51f9/html5/thumbnails/6.jpg)
Existing system (Cont...)
In electronic meter, current measure-current transformer and voltage-resistive voltage divides
An ADC converts these values into digital and it is given to microprocessor
Hence this calculate the energy consumption It has EEPROM employed for storing values over a 20
years of detection
6
![Page 7: Low cost ppt final](https://reader036.fdocuments.us/reader036/viewer/2022062400/58d071dc1a28abc9788b51f9/html5/thumbnails/7.jpg)
It’s Disadvantages
High labour cost Improper & Untimely billing Consumes high amount of power Loss of unaccountable energy & paperwork's Prone to power theft Cause high travel expenses and time consumption for
non reachable rural areas meter reading
7
![Page 8: Low cost ppt final](https://reader036.fdocuments.us/reader036/viewer/2022062400/58d071dc1a28abc9788b51f9/html5/thumbnails/8.jpg)
Proposed system overview
8
The urgent need is a low cost system that is available at a very low rate with accurate reading
The current and potential transformers are used to attenuates current and voltage respectively
This reduced values are conditioned using different elements to be compactable with the inbuilt ADC
The digital values are then processed by microcontroller hence the power consumption is calculated.
This microcontroller is connected to GSM module
![Page 9: Low cost ppt final](https://reader036.fdocuments.us/reader036/viewer/2022062400/58d071dc1a28abc9788b51f9/html5/thumbnails/9.jpg)
Proposed system overview (Cont…)
GSM modules sends information to users and suppliers via SMS
9
![Page 10: Low cost ppt final](https://reader036.fdocuments.us/reader036/viewer/2022062400/58d071dc1a28abc9788b51f9/html5/thumbnails/10.jpg)
Hardware Implementation
Current Transformer Current transformer produces a reduced current
accurately proportional to the current in the circuit, which can be conveniently connected to measuring and recording instruments.
Potential Transformer Potential transformer or voltage transformer gets used
in electrical power system for stepping down the system voltage to a safe value which can be fed to low ratings meters and relays.
10
![Page 11: Low cost ppt final](https://reader036.fdocuments.us/reader036/viewer/2022062400/58d071dc1a28abc9788b51f9/html5/thumbnails/11.jpg)
Hardware Implementation (Cont…)
Signal conditioning module It contains three elements Precision rectifier Ripple eliminator Voltage divider
Rectify the ac voltage-smooth dc voltage, reduced intensity compactable with microcontroller. These are mainly done with capacitor circuits
11
![Page 12: Low cost ppt final](https://reader036.fdocuments.us/reader036/viewer/2022062400/58d071dc1a28abc9788b51f9/html5/thumbnails/12.jpg)
Hardware Implementation (Cont...)
MicrocontrollerHere we use MSP430FG4618,Its specifications are• 80 I/O pins• Low supply voltage Range-1.8v to 3.6v• Ultra low power consumption(Active mode-400 μA)• 16bit RISC Architecture• 12-Bit A/D Converter• one universal synchronous/asynchronous
communication interface
12
![Page 13: Low cost ppt final](https://reader036.fdocuments.us/reader036/viewer/2022062400/58d071dc1a28abc9788b51f9/html5/thumbnails/13.jpg)
Hardware Implementation (Cont….)
• Integrated LCD Driver up to 160 Segments
Its computations• Power consumption is computed every second• Summing power consumption over a given period of
time gives energy used by a consumer13
![Page 14: Low cost ppt final](https://reader036.fdocuments.us/reader036/viewer/2022062400/58d071dc1a28abc9788b51f9/html5/thumbnails/14.jpg)
Hardware Implementation (Cont...)
Its computations• 1 kWh = 1 kW*1 hr = 1 kJ/s*3600s = 3600000 J• when the sum reaches 3600000, energy equivalent to
1 kW/hr or simply 1 unit is consumed• Real Time Clock(RTC) interrupts the controller every
second• RTC keeps track of date and time enabling the meter
console to send SMS at user configurable intervals.
14
![Page 15: Low cost ppt final](https://reader036.fdocuments.us/reader036/viewer/2022062400/58d071dc1a28abc9788b51f9/html5/thumbnails/15.jpg)
Hardware Implementation (Cont...)
GSM module• SIMCON sim900a GSM module is interfaced to the
microcontroller• The on chip UART communicates the usage
information to the GSM module• SMS is generated after regular interval of time which
can be sent to the local database for further processing of the billing
• The database contains information like customer identification number, meter no and no of unit consumed
15
![Page 16: Low cost ppt final](https://reader036.fdocuments.us/reader036/viewer/2022062400/58d071dc1a28abc9788b51f9/html5/thumbnails/16.jpg)
Software Implementation
AT commands of sim900a are used for establishing communication and conveying the usage information
• AT-initialise GSM module• AT+HVOIC-end all existing calls• AT+CMGF-set message format to text mode• AT+CMGS-followed by the destination number is used
to convey the same to the GSM module UART transmission is carried out at a baud rate of
9600
16
![Page 17: Low cost ppt final](https://reader036.fdocuments.us/reader036/viewer/2022062400/58d071dc1a28abc9788b51f9/html5/thumbnails/17.jpg)
17
![Page 18: Low cost ppt final](https://reader036.fdocuments.us/reader036/viewer/2022062400/58d071dc1a28abc9788b51f9/html5/thumbnails/18.jpg)
Results The power measured by the meter in testing phase for load
drawing up to 20A at 230V AC: When a graph is plotted on ACTUAL POWER V/S CALCULATED
POWER
18
![Page 19: Low cost ppt final](https://reader036.fdocuments.us/reader036/viewer/2022062400/58d071dc1a28abc9788b51f9/html5/thumbnails/19.jpg)
Results (Cont....)
The readings plotted using MATLAB give a fairly linear graph with an average error of 0.18%
The maximum consumption of the system is 2W/months
total cost of the unit including electronic components, controller, GSM module, and current and voltage sensors adds upto INR 1800 (less than $35)
SMS containing usage information
19
![Page 20: Low cost ppt final](https://reader036.fdocuments.us/reader036/viewer/2022062400/58d071dc1a28abc9788b51f9/html5/thumbnails/20.jpg)
Advantages
Reduce human dependency Reduction in technical problems Power theft is not possible Sends alerts on power cuts and communication
updates Low consumption of energy Low cost for implementation High security Timely billing will be possible
20
![Page 21: Low cost ppt final](https://reader036.fdocuments.us/reader036/viewer/2022062400/58d071dc1a28abc9788b51f9/html5/thumbnails/21.jpg)
Conclusion
Solution for automation in energy sector Decreasing the cost which is spent for billing and
distribution of bills On ultra-low power MSP430, consumes very small
amount of energy for its operation The microcontroller MSP430 is cheaper Tamper proof so electricity theft can be reduced Beneficial for both consumer as well as energy supplier Technical errors and corruptions can be avoided Hence it is a required system in India…..
21
![Page 22: Low cost ppt final](https://reader036.fdocuments.us/reader036/viewer/2022062400/58d071dc1a28abc9788b51f9/html5/thumbnails/22.jpg)
Future scope
□ used as a remainder-over usage of current by modifying the software.
□ A mini printer can be interfaced to get a printed bill or details of billing.
22
![Page 23: Low cost ppt final](https://reader036.fdocuments.us/reader036/viewer/2022062400/58d071dc1a28abc9788b51f9/html5/thumbnails/23.jpg)
References
1) Muhammad Saadi, Rabeel Manzoor, Lunchakorn Wuttisittikulkij, Proposal for Low Cost GSM based Electric Meter for Efficient and Automated Meter Reading for Developing Countries, Proceedings of the World Congress on Engineering 2012, London, U.K., Vol II, pp. 1024–1027, July 4 - 6, 2012
2) Texas Instruments, MSP430x4xx Family User’s Guide (Rev. J), http://www.ti.com/lit/ug/slau056j/slau056j.pdf
3) Load Generation balance Report 2012-13. Retrieved on Thursday 02, 2013 from http://www.cea.nic.in/
23
![Page 24: Low cost ppt final](https://reader036.fdocuments.us/reader036/viewer/2022062400/58d071dc1a28abc9788b51f9/html5/thumbnails/24.jpg)
24
![Page 25: Low cost ppt final](https://reader036.fdocuments.us/reader036/viewer/2022062400/58d071dc1a28abc9788b51f9/html5/thumbnails/25.jpg)
25