LOS ANGELES WORLD AIRPORTS Terminal Wayfinding Standards · 2018-02-06 · The Terminal Wayfinding...

78
LOS ANGELES WORLD AIRPORTS Terminal Wayfinding Standards 02-05-2018

Transcript of LOS ANGELES WORLD AIRPORTS Terminal Wayfinding Standards · 2018-02-06 · The Terminal Wayfinding...

LOS ANGELES WORLD AIRPORTSTerminal Wayfinding Standards

02-05-2018

Introduction .................................. 04–06S.1 Summary of Sign Types ........................................................04

S.2 Summary of Sign Types ........................................................05

1.1 Purpose ........................................................................................06

Wayfinding .................................... 07–082.1 What is wayfinding .................................................................07

2.2 Influencing factors ..................................................................08

2.3 Benefits of good wayfinding ..............................................08

Signage Design Guide .................... 09–173.1 Signage Systems ......................................................................09

3.2 Infrastructure Connectivity ................................................10

3.3 Typography.................................................................................12

3.4 Color Scheme ...........................................................................14

3.5 Pictograms .................................................................................15

3.6 Pathway .......................................................................................17

C_Customs and Border Protection .. 19–25C_1 CBP Wall Identity ....................................................................19

C_2 Welcome Identity ....................................................................20

C_3 Carousel Identity .....................................................................21

C_4 CBP Counter Identity ............................................................22

C_5 CBP Primary Checkpoint .....................................................23

C_6 Security Regulation ................................................................24

C_7 Hazmat regulation ..................................................................25

C

1

2

3

Contents

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

02 04-07-2017

G_Gates ......................................... 26–31G_1 Pier Identity ...............................................................................26

G_2 Departure Hall Identity ........................................................27

G_3 Gate Identity .............................................................................28

G_4 Gate Identity Sterile Corridor ...........................................29

G_5 Counter Identity ......................................................................30

G_6 TSA Identity Blade ..................................................................31

M_Miscellaneous ........................... 32–51M_1 Room Occupancy ....................................................................32

M_2 Life Safety Regulation Identity ..........................................33

M_3 Evacuation Plan Elevator .....................................................34

M_4 Elevator Directory ...................................................................35

M_5 Stairwell Identity .....................................................................36

M_6 Stair Identity ..............................................................................37

M_7 Floor Identity ............................................................................38

M_8 Area of Assistance Sign ........................................................39

M_9 Area of Evacuation Map/Stair Identity .........................40

M_10 Tactile Exit - Wall .....................................................................41

M_11 Exit Only No Re-Entry ...........................................................42

M_12 Restricted Area - Door ..........................................................43

M_13 Poster Frame .............................................................................44

M_14 Poster Stanchion .....................................................................45

M_15 Poster Stanchion .....................................................................46

M_16 Clearance Path .........................................................................47

M_17 Clearance Path - Wall ............................................................48

M_18 Clearance Bar ............................................................................49

M_19 Clearance - Wall Mounted ..................................................50

M_20 Evacuation Plan Reduced Size ..........................................51

R_Regulatory ................................. 52–61R_1 Room Identity ...........................................................................52

R_2 Multiple Room Identity ........................................................53

R_3 Defibrillator Room Identity ................................................54

R_4 Defibrillator Identity Vinyl ..................................................55

R_5 General Services Identity ....................................................56

R_6 Restroom Identity Door .......................................................57

R_7 Restroom Identity Wall ........................................................58

R_8 Restroom Identity Door No. ..............................................59

R_9 General Services Identity Wall ..........................................60

R_10 Wheelchair Accessible Stalls .............................................61

W_Wayfinding ............................... 62–77W_1 CBP Identity Sign ....................................................................62

W_2 Pedestrian Directional - Smaller Overhead ................63

W_3 Pedestrian Directional - Overhead .................................64

W_4 CBP Directional Static/Dynamic Overhead ................65

W_5 CSR Static Dynamic Overhead .........................................66

W_6 Wall Identity ..............................................................................67

W_7 Pedestrian Directional - Smaller Overhead ................68

W_8 Small Directional - Wall ........................................................69

W_9 Wayfinding Directional - Wall ...........................................70

W_10 Pedestrian Direction - Wall .................................................71

W_11 Informational Sign Placard .................................................72

W_12 Directional Sign Placard .......................................................73

W_13 Small Freestanding Directional ........................................74

W_14 Freestanding Directory.........................................................75

W_15 large Freestanding Directional .........................................76

W_16 Freestanding Directional .....................................................77

W_17 Pet Area Station .......................................................................78

G

M

R

W

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

03 09-12-2017

Contents

Summary of Sign Types

LEVEL 3����� �

IN FIREEMERGENCY,DO NOT USEELEVATOR

USE EXIT STAIRS

C_4 CBP COUNTER IDENTITYC_1 CBP WALL IDENTITY

(TERMINAL IDENTITY)

C_2 WELCOME IDENTITY C_3 BID/CAROUSEL ID

G_2 DEPARTURE HALL IDENTITY

C_5 CBP PRIMARY CHECKPOINT

Gate

G_3 GATE IDENTITY G_6 TSA IDENTITY BLADEG_4 GATE IDENTITYSTERILE CORRIDOR

G_5 COUNTER IDENTITY

M_13 POSTER FRAME M_14 POSTERSTANCHION

M_15 POSTERSTANCHION

M_10 EXIT ROUTEM_1 ROOM OCCUPANCY M_2 LIFE SAFETYREGULATORY IDENTITY

M_5 STAIRWELLIDENTITY

M_3 EVACUATIONPLAN ELEVATOR

M_20 EVACUATION PLANREDUCED SIZE

M_12 RESTRICTEDAREA - DOOR

M_9 AREA OF EVAC MAP/STAIR IDENTITY

M_11 EXIT ONLYNO RE-ENTRY

M_16 CLEARANCEPATH

M_17 CLEARANCEPATH WALL

KEEPCLEAR KEEP AREA CLEAR

AT ALL TIMES

CAUTION

M_18 CLEARANCE BAR M_19 CLEARANCE - WALL MOUNT

M_6 STAIR IDENTITY M_8 AREA OF ASSISTANCE SIGN

M_4 ELEVATORDIRECTORY

G_1 PIER IDENTITY

C_6 SECURITY REGULATION C_7 HAZMAT REGULATION

Federal law forbids the carriage of hazardous materials aboard aircraft in your luggage or on your person. A violation can result in five years' imprisonment and penalties of $250,000 or more (49 U.S.C. 5124). Hazardous materials include explosives, compressed gases, flammable liquids and solids, oxidizers, poisons, corrosives and radioactive materials. Examples: Paints, lighter fluid, fireworks, tear gases, oxygen bottles, and radio-pharmaceuticals.

There are special exceptions for small quantities (up to 70 ounces total) of medicinal and toilet articles carried in your luggage and certain smoking materials carried on your person. For further information contact your airline representative.

Hazardous Materials

FIRST CLASS BOARDINGU.S. CUSTOMS

LEVEL 4

AUTHORIZED ACCESS ONLY

5

3

GENERAL BOARDINGRESTROOMS4

M_7 FLOOR IDENTITY

STAIR 5NO ROOF ACCESS

2EXIT AT LEVEL 1

1 THRU 5

SPECIALSERVICES

EXIT ONLYNO RE-ENTRY

AREA FOREVACUATIONASSISTANCE Key Plan

Persons able to use stairway, do soas soon as possible.

Emergency communications systemis available 24 hours a day by usingphone for assistance.

Stair 1No Roof Access

Stair 6No Roof

EVAC MAP TBD

Access

380 WORLD WAY - LEVEL 3

Stairwell

Fire PullFire ExtinguisherArea of EvacuationAssistance

You Are HereExit RouteElevator

RESTRICTED AREA

L.A.M.C. 56.30 L.A. CITY ORDINANCE NO. 95-789

TRESPASSING / LOITERINGPROHIBITED BY LAW

ALL AUTHORIZED PERSONNEL MUSTDISPLAY ID BADGE BEYOND THIS POINT

AREA FOREVACUATIONASSISTANCE

FOR ASSISTANCEUSE PHONE

Key Plan

Persons able to use stairway, do soas soon as possible.

Emergency communications systemis available 24 hours a day by usingphone for assistance.

Stair 1No Roof Access

Stair 6No Roof

EVAC MAP TBD

Access

380 WORLD WAY - LEVEL 3

Stairwell

Fire PullFire ExtinguisherArea of EvacuationAssistance

You Are HereExit RouteElevator

EVACUATION PLAN300 WORLD WAY - LEVEL 3

Emergency Phone Number: 911Fire alarm sounds like a loud tone.Fire alarm looks like �ashing light.

Fire Extinguisher

Fire PullYou Are Here

Elevator Stairwell

Exit Route

IN CASE OF FIRE USE EXIT STAIRSDO NOT USE ELEVATOR

T3 - St.#5

EVACUATION PLAN300 WORLD WAY - LEVEL 3

Emergency Phone Number: 911Fire alarm sounds like a loud tone.Fire alarm looks like �ashing light.

Fire Extinguisher

Fire PullYou Are Here

Elevator Stairwell

Exit Route

IN CASE OF FIRE USE EXIT STAIRSDO NOT USE ELEVATOR

T3 - St.#5

EVACUATION PLAN300 WORLD WAY - LEVEL 3

Emergency Phone Number: 911Fire alarm sounds like a loud tone.Fire alarm looks like �ashing light.

Fire Extinguisher

Fire PullYou Are Here

Elevator Stairwell

Exit Route

IN CASE OF FIRE USE EXIT STAIRSDO NOT USE ELEVATOR

T3 - St.#5

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

04 01-30-2018

S.1

Summary of Sign Types

Gates150-159

Gates130-146

LoungeEscalatorsElevatorsRestrooms

RestaurantsDuty Free

W_2 PEDESTRIAN DIRECTIONAL- SMALLER OVERHEAD

W_10 PEDESTRIAN DIRECTIONAL - WALL

W_8 SMALL DIRECTIONAL -WALL

W_1 CBP IDENTITY

W_15 LARGE FREESTANDING DIRECTIONAL

W_16 FREESTANDING DIRECTORY

LoungesEscalatorsElevatorsRestrooms

RestaurantsDuty Free

Gates

Gates

150-159

130-146

Gates148

R_3 DEFIBRILATORIDENTITY BLADE

R_4 DEFIBRILATORIDENTITY VINYL

R_1 ROOM IDENTITY R_5 GENERALSERVICES IDENTITY

R_6 RESTROOM IDENTITYDOOR (TITLE 24)

R_7 RESTROOM IDENTITYWALL

R_9 GENERAL SERVICESIDENTITY - WALL

R_8 RESTROOM IDENTITYNO DOOR

R_2 MULTIPLE ROOM ID

W_11 INFORMATION SIGN PLACARD

W_12 DIRECTIONALSIGN PLACARD

W_17 PET RELIEFSTATION

PetReliefAreaPlease pick-upafter your pet.No Smoking.

PLEASE CLEAN UPAFTER YOUR DOG!

W_7 PEDESTRIAN DIRECTIONAL - SMALL OVERHEAD

W_3 PEDESTRIAN DIRECTIONAL - OVERHEAD

Restrooms

Restaurants

W_6 WALL IDENTITY

Customer Service Representative

W_4 CBP DIRECTIONAL STATIC/DYNAMIC OVERHEAD

W_5 CSR STATIC DYNAMICOVERHEAD

W_9 WAYFINDINGDIRECTIONAL - WALL

Rooms 00-00 Rooms 00-00

W_14 FREESTANDING DIRECTORY

Information Upper BoardingRestrooms

EXIT and Connecting FlightsGround Transport

Elevators

Cashier

W_13 SMALL FREESTANDINGDIRECTIONAL

CBPTRAINING��� ��������

Mr. John Doe0ffcr. Jane Doe

2-1-CR012-1-CR01

Gates 130-144Bag ClaimRestrooms

Exit

Bag ClaimRestrooms

RestroomsGates 130-144

Restaurants

Gates

Escalator

Lounge

Elevator

Shopping

Restrooms

Food

Gates 130-148N. ConcourseAirline LoungesShoppingRestroomsConcessions

W. 98th St.

Sky

Way 96th St. Bridge

P-2A

P-6VP-6VP

-4

P-2P-1

P-7

P-3

P-5P-4

Departure

East

Way

East

Way

Way

Departure

Arrival

Upper Level

Lower Level

Arrival

Upper Level

Lower Level

Lowe

r

Lev

el

Uppe

r

Lev

el

Tom

Bra

dley

Inte

rnat

iona

l Ter

min

al

Long-TermPublic Parking

Lot CFree Bus Serv ice t o

Airline Terminals

Long-TermPublic Parking

Lot B

Lincoln Blvd.

Arbor Vitae St.

W. 96th St.

Airp

ort

.dvlB

Century Blvd.

From I-405 Fwy.

104th St.

111th St.

Imperial Hwy

Free Bus Serv ice t oAirline Terminals

La C

iene

ga

.dvlB

Wes t

evlupeSda

Blv

d.

Wes

t

Center Way

Uppe

r Lev

el

Low

er L

evel

Wes

t Way

1

1

123

4 5 6 7 8405

405

105

NORTH

Metro Rail Green LineImperial Hwy. & Aviation Blvd.

Lot B111th & La Cienega Blvd.

Cell Phone Waiting LotAirport Blvd. & Arbor Vitae St.

R_10 RESTROOM IDENTITYPRIORITY STALL

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

05 09-12-2017

S.2

08-04-2015

1.1Purpose The Terminal Wayfinding Standards for Los Angeles World Airports has

been developed to assist the industry involved in delivering wayfinding

information to travellers at Los Angeles International Airport.

The Standards includes information and advice on wayfinding practices as

well as guidance on designing signs. It is intended to provide a reference

and instruction on the important aspects of wayfinding as well as sources

for more detailed and specific information.

The use of the Standards should be taken into consideration in wayfinding

planning activities throughout all terminals at LAX. Any variations to the

guidelines should be presented to the proper department for approval.

All signs in these standards are in compliance with the current ADA

guidelines that regulates the size of symbols and accompanying text. To

further aid the traveling public, LAWA emphasizes the use of international

symbols on its wayfinding. TBIT West signs currently have smaller

pictograms. Super graphics incorporating international symbols can be

utilized as a wayfinding aid supplementing the existing signage to make the

path of travel an intuitive experience.

1 INTRODUCTION

06

Los

Ang

eles

Wor

ld A

irpor

ts

| T

erm

inal

Way

findi

ng S

tand

ards

|

Int

rodu

ctio

n

08-04-2015

Los

Ang

eles

Wor

ld A

irpor

ts

| T

erm

inal

Way

findi

ng S

tand

ards

|

Way

find

ing

072 WAYFINDING

2.1What is Wayfinding Wayfinding can be defined as a process in which people navigate an

environment using information support systems such as architectural clues,

lighting, sight lines and signage.

Successful wayfinding systems can be measured by how travellers

experience the airport environment and how the information facilitates

self-navigation from point A to point B. Wayfinding systems should create

a welcoming and enjoyable environment, reassure travellers and provide

answers to questions before they have to ask for assistance.

Wayfinding is achieved by focussing on the travellers needs, especially

during the planning and design phases, and encompasses environmental

factors, building design, user expectation and signage information.

Wayfinding systems should provide the following information

to travellers:

• identify their location

• reinforce they are travelling in the right direction

• identify their destination on arrival (of each area)

• know where to exit safely in an emergency

Wayfinding information can be delivered through the following:

• dynamic information

• static signs

• temporary information

• lighting

• building design

• user’s prior knowledge and experience

• staff

• audible information

08

08-04-2015

2.2Influencing FactorsHUMAN

These are the factors concerned with the individual and their ability to

interpret wayfinding information being conveyed to them. This is influenced

by their experience in the airport environment and their familiarity with the

type of information they encounter. Inexperienced travellers tend not to

have a good understanding of how to move through an airport and will look

for more information.

When a person is unable to locate the information they require, they will

seek alternative sources such as asking staff. People are unable to store

a lot of information in their short term memory and they may ignore

important information when they are unable to distinguish it from other

less relevant information.

INFORMATION

The type of information provided to travellers (visual, audible or physical)

and how they interpret and understand this information will affect how

they find their way through the airport.

Wayfinding information that is similar to other airport information may be

confusing and should be avoided wherever possible. Travellers should be

able to distinguish wayfinding information from other types of information,

such as operational or advertising.

ENVIRONMENT

An airport’s physical layout and architectural features will also influence

successful wayfinding. Providing information and reassurance at decision

points will help travellers make decisions. The use of sight lines and other

visual clues will also aid wayfinding.

2.3Benefits of Good Wayfinding Travellers need consistent, concise, accurate and timely information when

they are in the airport environment. If a traveller is unable to find their way

it can lead to frustration and a poor experience.

Good wayfinding can offer a number of benefits, including:

• traveller satisfaction

• reduce clutter and unnecessary information in the airport environment

• aid traveller flow and reduce airport crowding

• assist travellers get to their flights on time

• allows travellers to reach their destination easily and quickly, allowing

them time to explore their environment (e.g. shopping, eating, relaxing)

• reduce enquiries to airport staff

Los

Ang

eles

Wor

ld A

irpor

ts

| T

erm

inal

Way

findi

ng S

tand

ards

|

Way

find

ing

09

Los

Ang

eles

Wor

ld A

irpor

ts

| T

erm

inal

Way

findi

ng S

tand

ards

|

Sig

nage

Des

ign

Gui

de

08-04-2015

3 SIGNAGE DESIGN GUIDE

3.1Signage SystemsThe primary purpose of an airport sign system is to move travellers through

the airport using a concise and comprehensive system of directional,

operational, informational and regulatory messages.

The following are sign design guidelines for use at all of the Los Angeles

International Airport terminals.

Signs should be positioned to ensure consistency, visual clutter is reduced

and travellers are presented with key information at critical decision

making points.

Avoid positioning several contrasting signs in close proximity to each

other. Signs and posters should not compete with other signs for the user’s

visual attention.

Provide travellers with key information at critical decision making points. To

support decision making, travellers need clear directions at decision points.

10

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

03-07-2017

3.2

GENERAL REQUIREMENTS FOR INFRASTRUCTURE

Admonition to Environmental Graphics Designers

When working for Los Angeles World Airports (LAWA), designers must

adhere to the following procedures during the design phases of all

signage projects. All submittals shall conform to the design direction set

forth in this design manual.

It is expected and required that all environmental graphics designers

participating in any graphics/signage projects with LAWA ensure that

all work associated with the fabrication and installation of the signage

maintain its aesthetic integrity.

Engineering services must be retained for the purpose of graphics/

signage construction in order for documentation to be complete and

thorough. This documentation includes, but is not limited to structural,

electrical, data, and any other engineering services required for the

successful implementation of the graphics/signage program.

It shall be the responsibility of the engineering/fabricating team to

perform the complete review of the sign’s infrastructure connections and

to incorporate all the reasonable safety factors necessary to protect the

Owner and their representatives, against public liability.

All electrical and data requirements shall be identified by an electrical

engineer, licensed in the State of California and will provide all “panel to

install locations” specifications and circuitry information.

The sign fabricator will review all types of signs, messages, and graphics

that are indicated on the design drawings and specifications, and

confirm various materials, finishes, electrical and data requirements. The

structural design and calculations for all signage will require certification

by an Engineer licensed in the State of California. The fabricator will

complete the structural design of the signs and coordinate with the

engineer and/or general contractor for infrastructure connections.

Submittal documents (shop drawings) shall be complete in application,

size, details, materials and specifications and reflect the sign types and

designs described in this manual. The Engineering team will coordinate

with the sign fabricator and the general contractor on all infrastructure

footings, structural attachments, and penetrations of slabs in new and

existing building conditions.

Infrastructure Connectivity

11

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

03-07-2017

Infrastructure Connectivity Details 3.2

CEILING CONNECTION CONFIGURATION OPTIONS

FLOOR CONNECTION CONFIGURATION OPTIONS

WALL CONNECTION CONFIGURATION OPTIONS

STEELSTRUCTUREV.I.F.

RESTORE FIREPROOFINGOF STEEL BEAM

RESTORE FIREPROOFINGOF STEEL BEAM

RESTORE FIREPROOFINGOF STEEL BEAM

VERIFY

BASE PLATE

ANCHOR AS REQUIRED

ELECTRICAL AND DATA

FEEDS

THICKENED SLAB

FINISHED FLOOR

SIGN CABINET

BASE PLATE

ANCHOR AS REQUIRED

ELECTRICAL AND DATA CONDUIT AS REQ’D

SLAB

FINISHED FLOOR

SIGN CABINET

SIGN CABINET INTERNAL J-BOX

SECTION DETAILD

FACILITY WALL (VERIFY)

MOUNTING HARDWARE AS REQUIRED

BLOCKING AS REQUIRED

SECTION DETAILA

SECTION DETAILE SECTION DETAILF

SECTION DETAILB SECTION DETAILC

ESCUTCHEON COVER

MOUNTING PLATE

SIGN CABINET

12

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

08-04-2015

Typography3.3Helvetica Neue Lt Pro 65 Medium

Helvetica Neue Lt Pro 75 Bold

08-04-2015

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

13

Typography 3.3Franklin Gothic ITCBY BT – Demi

Joanna MT Semibold Regular

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

14 03-07-2017

Color Scheme

Paint

Materials

3.4

NOTE: CONTRACTED GRAPHICS DESIGNER IS TO PROVIDE TERMINAL SPECIFIC COLORS WITH PAINT SPECIFICATIONS FOR EACH SIGNAGE PACKAGE FOR REVIEW AND APPROVAL. DESIGNER TO PROVIDE THREE(3) PAINT SAMPLES OF EACH COLOR PROPOSED. MINIMUM SIZE FOR COLOR SAMPLES IS 3”X3”.

NOTE: CONTRACTED GRAPHICS DESIGNER IS TO PROVIDE TERMINAL SPECIFIC MATERIALS WITH SPECIFICATIONS FOR EACH SIGNAGE PACKAGE FOR REVIEW AND APPROVAL. DESIGNER TO PROVIDE THREE(3) PAINT SAMPLES OF EACH FINISH AND MATERIAL PROPOSED. MINIMUM SIZE FOR SAMPLES IS 6”X6”.

15

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

02-05-2018

Pictograms 3.5

Terminal

MEN RESTROOM

WAITING ROOM

VENDING MACHINES

FORWARD AND RIGHT ARROW

CURRENCY EXCHANGE

WOMEN RESTROOM

LITTER DISPOSAL

PLAY AREA

LEFT AND DOWNARROW

TICKET PURCHASE

ALL GENDER RESTROOM

ATM

BAGGAGE

RIGHT AND DOWNARROW

PUBLIC PHONECOURTESY PHONE

NURSING ROOM

RESTAURANT

PARKING

RIGHT ARROW

SMOKING

ELEVATOR

FOOD

NO ENTRY

LEFT ARROW

ANIMAL CARE

ACCESSIBLE ELEVATOR

DRINKING FOUNTAIN

INFORMATION

DOWN ARROW

PET AREA (EXTERNAL USE)

STAIRS

WATER DISPENSER

CLEAN AIR

U-TURN ARROW

PET AREA(INTERNAL USE)

CHANGING ROOM

SHOPS

BUSINESS CENTER

UP ARROW

NO SMOKING

RESTROOM

ESCALATOR

COMPUTER STATION

COFFEE SHOP FORWARD AND LEFT ARROW

CASHIER

15

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

16

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

07-18-2017

Pictograms

Roadway

International Travel

Accessible

Emergency

3.5

* Where pictograms are provided as designations of permanent interior rooms and spaces,

they shall comply with requirements for minimum field height, finish and contrast, and they

shall be accompanied by compliant tactile (raised letter and braille) descriptors. Directional

and informational pictograms are not required to have tactile descriptors.

GROUND TRANSPORT

TTY

DEFIBRILLATOR

AGRICULTURE

CAR RENTAL

HEARING LOSS

INFORMATION

IMMIGRATION

LAX TRANSPORTATION

VOLUMN CONTROLTELEPHONE

EXIT

GATES CONNECTING FLIGHT DEPARTING FLIGHTS ARRIVING FLIGHTSBUSTAXI

ACCESSIBLE

FIRST AID

CUSTOMS

16

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

17

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

04-07-2017

Pathway

RIGHT

LEFT

DOWN ON LEFT

DOWN

DOWN ON RIGHT

STRAIGHT AHEAD

UP

AHEAD ON LEFT

UP ON LEFT

AHEAD ON RIGHT

UP ON RIGHT

INTERPRETATIONPLANLOCATION

ORIENTATIONAPPLICATION/ INTERPRETATIONPLAN

LOCATIONORIENTATIONAPPLICATION/

3.6Orientation & Interpretation

18

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

04-07-2017

Pathway

Decision point

Sight lineCirculation path

Sign

Terminal 3example

Point or approach areawhere passenger must

make a directional decision

22'-0" +- viewing distance

Concourse NorthConcourse South

Decision Point Diagram

3.6

Minimum font heights when viewed from distance:20’ - 3”25’ - 3 3/4”30’ - 4 1/2”

19

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

08-04-2015

CBP Wall Identity C_1CBP Signage Contact Information

NOTE: CBP SIGNAGE MAY BE REQUIRED IN THE TERMINALS. CONTACT THE FOLLOWING FOR DETAILED SIGNAGE INFORMATION AND STANDARDS.

CUSTOMS & BORDER PROTECTION GENERAL PRINTING & GRAPHICS (202) 344-1310

CUSTOMS & BORDER PROTECTION MISSION SUPPORT (562) 980-3140 ext.102

20

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

08-04-2015

Welcome IdentityC_2

Sign Type Design

Location

Dimensions

Location

Dimensions

Location

Dimensions

Location

Dimensions

Location

Dimensions

Location

Dimensions

Gate Identity Sterile Corridor

Customs Secondary IdentityWelcome Identity

Area of Refuge/Evac Map/Stair ID

Area of Refuge Sign

G_3

C_6C_5

R_10

R_9 BOH Multiple Room IDR_11

FOR ASSISTANCE USE PHONE

Persons able to use stairway, do so as soon as possible.

To summon assistance follow instructions.

Emergency communications system is available 24 hours a day by using phone for assistance.

Stair 1No Roof Access

Stair 6No RoofAccess

YOU ARE HERE AREA FOREVACUATIONASSISTANCEEXIT ROUTE

ELEVATOR

STAIRWELL

FIRE PULL

FIRE EXTINGUISHER

AREA FOR EVACUATION ASSISTANCE

Admissibility Review

380 WORLD WAY

Emergency Phone Number: 911Fire alarm is a loud tone with flashing strobe

IN CASE OF FIRE USE EXIT STAIRSDO NOT USE ELEVATOR

EVACUATION PLAN

LEVEL 3

YOU ARE HERE AREA FOR EVACUATION ASSISTANCEEXIT ROUTE

ELEVATOR

STAIRWELL

FIRE PULL

FIRE EXTINGUISHER

Stair 1No Roof Access

Stair 6No RoofAccess

3/16"

3/16"

AREA FOR EVACUATION ASSISTANCE

EXIT STAIRS DOWNEVACUATION ASSISTANCE

TRAININGCBP

��� ��������

Mr. John Doe0�cr. Jane Doe

2-1-CR01

FRONT ELEVATION1 NOT TO SCALE

CONTEXT ELEVATION3 NOT TO SCALE

SIDE VIEW2 NOT TO SCALE

GENERAL NOTES: 1. FABRICATED ALUMINUM LETTERFORMS AND LOGO. 2. LETTER FACES AND RULE LINES TO BE VERTICAL BRUSHED FINISH WITH

MIRROR POLISHED RETURNS. 3. 3” THICK LETTERFORMS AND RULE TO BE PIN MOUNTED 1/2” FROM FACILITY

WALL WITH THREADED WELDED STUDS, PAINTED NON-CORROSIVE SPACERS AND EPOXY ADHESIVE.

4. VERIFY WALL CONSTRUCTION PRIOR TO FABRICATION OF SIGN.

5. SIGNAGE SHOWN IS FOR PLACEMENT PURPOSES ONLY. FINAL MESSAGE AND LOCATION OF SIGN TO BE PROVIDED BY LAWA.

REFER TO NOTE FROM SIGN TYPE C_1

11 3/4"

1 1/8"

11 3/4"

21

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Carousel Identity C_3

SECTION DETAIL5 NOT TO SCALE

FRONT ELEVATION1 NOT TO SCALE

TOP ELEVATION4 NOT TO SCALE

SIDE ELEVATION2 NOT TO SCALE

GENERAL NOTES: 1. DOUBLE SIDED SIGN CABINET WITH LCD DISPLAYS. 2. SIGN CABINET TO HAVE INTERNAL FRAMING AND CLADDED WITH BRUSHED

ALUMINUM. PROVIDE INCONSPICUOUS ACCESS AS REQUIRED FOR EASE OF MAINTENANCE. EXPOSED EDGES OF ALUMINUM TO BE POLISHED.

3. FABRICATED ALUMINUM SIGN PANEL PAINTED IN COLOR NOTED. 4. NUMERALS TO BE FLAT-CUT-OUT ALUMINUM WITH PAINT FINISH AS NOTED.

ADHERE TO SIGN PANEL WITH HIDDEN MECHANICAL FASTENERS. 5. LCD ARRAY DYNAMIC DISPLAY SCREENS TO BE PROVIDED BY LAWA/GC

(EXAMPLE: NEC P701 70” - USE CURRENT SPECIFICATION). INSTALL INTO SIGN CABINET IN A MANNER TO ALLOW EASE OF MAINTENANCE. MONITORS TO BE LOCKED INTO PLACE. COORDINATE WITH LAWA/GC FOR DISPLAY REQUIREMENTS. WEIGHT OF MONITORS IS APPROXIMATELY 220 LBS EACH. PROVIDE APPROPRIATE STRUCTURAL SUPPORT AS REQUIRED BY STRUCTURAL ENGINEERING CALCULATIONS. DETAIL SHOWN IS ONLY A SUGGESTION.

6. FINAL MESSAGE PER SIGN LOCATION TO BE PROVIDED BY LAWA. 7. DESIGNER TO FIELD VERIFY AND DETERMINE BEST METHOD OF INSTALLATION.

DESIGNER TO PROVIDE STRUCTURAL ENGINEERING CALCULATIONS AS REQUIRED AND COORDINATE WITH GENERAL CONTRACTOR FOR STRUCTURAL REQUIREMENTS.

8. TOTAL APPROXIMATE WEIGHT: 850 LBS. TOTAL APPROXIMATE WATTAGE REQUIREMENT: 1500W 9. SIGN CABINET BASE TO BE CLADDED WITH BRUSH FINISHED ALUMINUM.

NOTE: ALL TEXT MUST COMPLY WITH THE ADA STANDARDS, INCLUDING FONT SIZE,

COLOR CONTRAST AND READABILITY FROM A DISTANCE.

5

HINGED DOOR ASSEMBLY

MONITOR

TBD

SIGN PANEL 3.

SIGN CABINET 2.

Sign Type Design

22

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

CBP Counter IdentityCBP Primary CheckpointCBP Counter Identity

CBP Wall Identity

C_4C_2

C_1

AED Identity

CBP Carousel Identity

M_4

C_3

Location

Dimensions

Location

Dimensions

Location

Dimensions

Location Above checkpoint kiosks

Dimensions Cabinet: 3’-5” x 2’-10”Screen: 2’-11” x 1’-8”

Gate IdentityG_2

Location

Dimensions

Location

Dimensions

Signage Details Sheet SD_04C_4

Sign Type DesignGENERAL NOTES: 1. NON-ILLUMINATED IDENTIFICATION NUMBER PLAQUES AND APPLIED VINYL LOGOS. 2. SIGN PANEL BACKGROUND TO BE ALUMINUM WITH BRUSHED FINISH. 3. SIGN PANEL TO BE PAINTED ALUMINUM PERMANENTLY ATTACHED TO SIGN BACKGROUND. 4. NUMERALS TO BE FLAT-CUT-OUT PAINTED ALUMINUM AND APPLIED TO SIGN PANEL WITH ALIGNMENT PINS AND ADHESIVE AS REQUIRED. 5. GRAPHIC LOGOS (WHERE OCCURS) TO BE APPLIED VINYL. “GLOBAL ENTRY” LOGO TO FOLLOW CBP GUIDELINES. REFER TO CBP.GOV FOR INFORMATION. LAWA TO PROVIDE SPECIFIC LOGO LOCATIONS. 6. SIGN TO BE MOUNTED TO PODIUM WITH THREADED WELDED STUDS AND SILICONE ADHESIVE AS REQUIRED. 7. FINAL MESSAGE PER SIGN LOCATION TO BE PROVIDED BY LAWA.

FRONT ELEVATION1 NOT TO SCALE

DETAIL PLAN VIEW2 NOT TO SCALE

CONTEXT ELEVATION3 SCALE: 3/16” = 1’-0”

C_2 - CUSTOMS CHECKPOINT IDENTITY

SIGN BACKGROUND

SIGN PANEL 3.

NUMERALS 4.

SIGN BACKGROUND 1/8”1/8”

1/8”SIGN PANEL 3.

NUMERALS 4.

PODIUM 6.

GLOBAL ENTRY LOGO 5.

GENERAL NOTES: 1. NON-ILLUMINATED IDENTIFICATION NUMBER PLAQUES AND APPLIED VINYL

LOGOS. 2. SIGN PANEL BACKGROUND TO BE ALUMINUM WITH BRUSHED FINISH. 3. SIGN PANEL TO BE PAINTED ALUMINUM PERMANENTLY ATTACHED TO SIGN

BACKGROUND. 4. NUMERALS TO BE FLAT-CUT-OUT PAINTED 1/8” ALUMINUM AND APPLIED TO

SIGN PANEL WITH ALIGNMENT PINS AND ADHESIVE AS REQUIRED. 5. GRAPHIC LOGOS (WHERE OCCURS) TO BE APPLIED VINYL. “GLOBAL ENTRY”

LOGO TO FOLLOW CBP GUIDELINES. REFER TO CBP.GOV FOR INFORMATION. LAWA TO PROVIDE SPECIFIC LOGO LOCATIONS.

6. SIGN TO BE MOUNTED TO PODIUM WITH THREADED WELDED STUDS AND

SILICONE ADHESIVE AS REQUIRED. 7. FINAL MESSAGE PER SIGN LOCATION TO BE PROVIDED BY LAWA.

FRONT ELEVATION1 SCALE: 1 1/2” = 1’-0”

DETAIL PLAN VIEW2 SCALE: 1 1/2” -= 1’-0”

CONTEXT ELEVATION3 SCALE: 3/16” = 1’-0”

SIGN BACKGROUND

SIGN PANEL 3

NUMERALS 4

SIGN BACKGROUND 2 1/8”1/8”

1/8”SIGN PANEL 3

NUMERALS 4

PODIUM 6

GLOBAL ENTRY LOGO 5.

23

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

04-07-2017

CBP Primary Checkpoint C_5

Sign Type Design4'-0"

2'-0"

2'-11”

1'-7 1/2"

1’-0"

1'-3"

6 3/4"

7 8

7 8

7 8

8

3 3/8"

FRONT ELEVATION1 SCALE: 1” = 1’-0”

OPTIONAL CONFIGURATION3 SCALE: 1/2” = 1’-0”

SECTION2 SCALE: 1” = 1’-0”

VERIFY STRUCTURE ABOVE

PLAN

ELEVATION SIDE

MASKED AND PAINTED FIELD

GENERAL NOTES: 1. CEILING MOUNTED DISPLAY MONITOR INCASED IN A FABRICATED ALUMINUM

CABINET WITH INTERNAL ILLUMINATION FOR NUMERALS, ARROWS, AND RED/GREEN LIGHTING.

2. MONITOR TO BE NEC 40” #P401 AND SUPPLIED BY OWNER. PROVIDE AND

INSTALL MOUNTING BRACKET AS REQUIRED BY STRUCTURAL ENGINEERING CALCULATIONS.

3. CABINET AND SHROUD TO BE FABRICATED WITH BRUSHED ALUMINUM AND

HAVE INTERNAL FRAMING AS REQUIRED. PROVIDE INCONSPICUOUS ACCESS PANELS FOR MAINTENANCE.

5. INTERNAL ILLUMINATION TO BE WHITE LED. 6. RED/GREEN LIGHTS TO BE PUSH-THRU TRANSLUCENT WHITE ACRYLIC AND

INTERNALLY ILLUMINATED WITH INDEPENDANTLY CONTROLLED RED AND GREEN LED LIGHTING. SURFACE OF PUSH-THRU LENS TO BE FLUSH WITH CABINET SURFACE. PROVIDE 3 SETTINGS PER LENS, RED, GREEN AND OFF.

7. PRIOR TO BID SUBMISSION, VERIFY FACILITY STRUCTURE PRIOR TO SIGNAGE

FABRICATION. PROVIDE MOUNTING BRACKET AS REQUIRED BY STRUCTURAL ENGINEERING CALCULATIONS.

8. PRIOR TO BID SUBMISSION, COORDINATE STRUCTURAL, ELECTRICAL AND

DATA REQUIREMENTS WITH GENERAL CONTRACTOR. 9. LAWA TO PROVIDE SPECIFIC MESSAGING PER SIGN LOCATION.

NOTE: THE SCALE OF THE SIGNAGE AND GRAPHICS ARE SUBJECT TO CHANGE IN

ORDER TO BE COMPLIANT WITH ADA GUIDELINES IF THE INSTALLATION SITE EXCEEDS THE HEIGHT SHOWN IN THE DRAWING PROVIDED.

ALL TEXT MUJST COMPLY WITH ADA STANDARDS INCLUDING TEXT HEIGHT, COLOR CONTRAST AND READABILITY FROM A DISTANCE AND ILLUMINATION.

VINYL GRAPHICS

6'-8

" MIN

.

CBP Primary CheckpointCBP Counter Identity

CBP Wall Identity

C_4C_2

C_1

AED Identity

CBP Carousel Identity

M_4

C_3

Location

Dimensions

Location

Dimensions

Location

Dimensions

Location Above checkpoint kiosks

Dimensions Cabinet: 3’-5” x 2’-10”Screen: 2’-11” x 1’-8”

Gate IdentityG_2

Location

Dimensions

Location

Dimensions

Signage Details Sheet SD_04

24

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Security Regulation

Sign Type Design

C_6

GENERAL NOTES: 1. 1/8” THICK WHITE SINTRA PANEL WITH SCREENED GRAPHICS. 2. MOUNT TO WALL WITH SILICONE ADHESIVE AND DOUBLE-SIDED TAPE. 3. SIGNAGE SHOWN IS FOR PLACEMENT PURPOSES ONLY. OBTAIN MESSAGE

AND SIGNAGE CRITERIA FROM LAWA.

FRONT ELEVATION1 NOT TO SCALESIDE ELEVATION2 NOT TO SCALE

1/8”

1'-10"

5/16"5/16"

1/4"1/4"

1/2"1/2"

1/2"

1/2"1/8"1/2"

5/8"

10 3/4"

9 1/4"3/4" 3/4"

C L

MOUNT WITH SILICONE ADHESIVEAND DLUBLE-SIDED TAPE

US DEPARTMENT OF HOMELAND SECURITYRULES AND REGULATIONS• Airport operators, in consultation with their FSD, must develop and incorporate into their TSA-approved ASP, Aviation Security (AVSEC) Contingency Plans that are tailored to the airport. AVSEC systems, methods and procedures should address specific HSAS levels. In developing the plan, the airport operator and FSD must consider the relative risk to the airport, existing vulnerabilities identified through a vulnerability assessment of the airport, unique characteristics of the airport, and resources available to the airport.When the Secretary of the Department of Homeland Security declares the nation at an enhanced threat condition, the airport operator and others must immediately implement the corresponding security measures contained in the AVSEC Contingency Plan and all appropriate security directives.

• In addition, the airport operator is responsible to ensure that an FAA-approved Airport Emergency Plan (AEP), is coordinated with the TSA FSD and included in the overall Airport Operations Manual for FAA certification of the airport. The AEP will identify the local emergency response agencies (hospitals, emergency medical services, mutual-aid first responders, military and federal support agencies, etc.) and types of services which will need to be accommodated and may require additional facilities during emergency conditions.

• Airport operators, in consultation with their FSD, must develop and incorporate into their TSA-approved ASP, Aviation Security (AVSEC) Contingency Plans that are tailored to the airport. AVSEC systems, methods and procedures should address specific HSAS levels. In developing the plan, the airport operator and FSD must consider the relative risk to the airport, existing vulnerabilities identified through a vulnerability assessment of the airport, unique characteristics of the airport, and resources available to the airport.When the Secretary of the Department of Homeland Security declares the nation at an enhanced threat condition, the airport operator and others must immediately implement the corresponding security measures contained in the AVSEC Contingency Plan and all appropriate security directives.

US DEPARTMENT OF HOMELAND SECURITYRULES AND REGULATIONS• Airport operators, in consultation with their FSD, must develop and incorporate into their TSA-approved ASP, Aviation Security (AVSEC) Contingency Plans that are tailored to the airport. AVSEC systems, methods and procedures should address specific HSAS levels. In developing the plan, the airport operator and FSD must consider the relative risk to the airport, existing vulnerabilities identified through a vulnerability assessment of the airport, unique characteristics of the airport, and resources available to the airport.When the Secretary of the Department of Homeland Security declares the nation at an enhanced threat condition, the airport operator and others must immediately implement the corresponding security measures contained in the AVSEC Contingency Plan and all appropriate security directives.

• In addition, the airport operator is responsible to ensure that an FAA-approved Airport Emergency Plan (AEP), is coordinated with the TSA FSD and included in the overall Airport Operations Manual for FAA certification of the airport. The AEP will identify the local emergency response agencies (hospitals, emergency medical services, mutual-aid first responders, military and federal support agencies, etc.) and types of services which will need to be accommodated and may require additional facilities during emergency conditions.

• Airport operators, in consultation with their FSD, must develop and incorporate into their TSA-approved ASP, Aviation Security (AVSEC) Contingency Plans that are tailored to the airport. AVSEC systems, methods and procedures should address specific HSAS levels. In developing the plan, the airport operator and FSD must consider the relative risk to the airport, existing vulnerabilities identified through a vulnerability assessment of the airport, unique characteristics of the airport, and resources available to the airport.When the Secretary of the Department of Homeland Security declares the nation at an enhanced threat condition, the airport operator and others must immediately implement the corresponding security measures contained in the AVSEC Contingency Plan and all appropriate security directives.

1’-3”

25

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Hazmat Regulation C_7

Sign Type Design

11"

3"

1'-2 1/4”

1'-5”

2 3/4"

7/8"

5/8"

1/2"1/2"

3/4"

3/4"

3/18"

1/4"

1/4"1/4"

Federal law forbids the carriage of hazardous materials aboard aircraft in your luggage or on your person. A violation can result in five years' imprisonment and penalties of $250,000 or more (49 U.S.C. 5124). Hazardous materials include explosives, compressed gases, flammable liquids and solids, oxidizers, poisons, corrosives and radioactive materials. Examples: Paints, lighter fluid, fireworks, tear gases, oxygen bottles, and radio-pharmaceuticals.

There are special exceptions for small quantities (up to 70 ounces total) of medicinal and toilet articles carried in your luggage and certain smoking materials carried on your person. For further information contact your airline representative.

Hazardous Materials

FRONT ELEVATION1 NOT TO SCALESIDE ELEVATION2 NOT TO SCALE

GENERAL NOTES: 1. 1/8” THICK WHITE SINTRA PANEL WITH SCREENED GRAPHICS. 2. MOUNT TO WALL WITH SILICONE ADHESIVE AND DOUBLE-SIDED TAPE. 3. SIGNAGE SHOWN IS FOR PLACEMENT PURPOSES ONLY. OBTAIN MESSAGE

AND SIGNAGE CRITERIA FROM LAWA.

NOTE: ALL TEXT MUST COMPLY WITH THE ADA STANDARDS, INCLUDING FONT SIZE,

COLOR CONTRAST AND READABILITY.

1/8”

MOUNT WITH SILICONE ADHESIVEAND DLUBLE-SIDED TAPE

26

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

04-07-2017

SECTION DETAIL2 NOT TO SCALESECTION DETAIL1 NOT TO SCALE

& SUBSTATIONINCOMING SWITCH

1100

Restroom Identity Oversize Baggage Identity

BOH Room Identity Animal Arrival Directional Wall

Pier Identity AED Identity

3'-0"

2'-0"4'-0"

Location

Dimensions

Location

Dimensions

Location

Dimensions

Location

Dimensions

Location

Dimensions

Location

Dimensions

M_1R_7

R_8

G_1

M_2

M_3

WOMEN

Sign Type Design

Pier IdentityG_1

Sign Type Design

27

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

08-04-2015

Sign Type Design

Departure Hall Identity G_2

W_1 DEPARTURE HALL IDENTITY

FRONT ELEVATION1 NOT TO SCALE

GENERAL NOTES: 1. NON-ILLUMINATED, DIMENSIONAL LETTERING MOUNTED TO WALL. 2. FABRICATED ALUMINUM LETTERS WITH PAINTED FINISH.

3. MESSAGE, SIZE, AND LOCATION TO BE DETERMINED BY LAWA. 4. FONT: HELVETICA NEUE LT PRO 85 HEAVY

28

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Gate IdentityG_3

Sign Type DesignGENERAL NOTES: 1. DOUBLE-FACED, NON ILLUMINATED, FREESTANDING PYLON SIGN WITH

DIMENSIONAL COPY. 2. FABRICATED ALUMINUM CABINET WITH INTERNAL STRUCTURE AS REQUIRED. 3. SIGN PANELS TO BE FABRICATED ALUMINUM PAINTED IN COLOR INDICATED.

ATTACH TO SIGN CABINET IN AN INCONSPICUOUS MANNER. 4. COPY TO BE FLAT-CUT-OUT PAINTED ALUMINUM FLUSH MOUNTED TO SIGN

PANEL WITH HIDDEN MECHANICAL FASTENERS. FACE AND EDGES OF COPY TO BE PAINTED IN COLOR INDICATED.

5. DESIGNER TO FIELD VERIFY AND DETERMINE BEST METHOD OF INSTALLATION.

DESIGNER TO PROVIDE STRUCTURAL ENGINEERING CALCULATIONS AS REQUIRED AND COORDINATE WITH GENERAL CONTRACTOR FOR FOOTING REQUIREMENTS.

6. LAWA TO PROVIDE SPECIFIC MESSAGES PER SIGN LOCATION.

FRONT ELEVATION1 NOT TO SCALE

SIDE ELEVATION2 NOT TO SCALE

9'-0"

1'-1"

3 1/2"

2 3/4"

8"

8'-4"

8"

2 1/4"

11"

C L

COPY 4. 6.

COPY 4. 6.

Gate

FOOTING 5.

29

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

04-07-2017

Gate Identity Sterile Corridor G_4

Sign Type Design

FRONT ELEVATION1 NOT TO SCALESIDE ELEVATION2 NOT TO SCALE

GENERAL NOTES: 1. NON-ILLUMINATED SIGN PANEL WITH MOUNTING BRACKET. 2. BACKGROUND PANEL TO BE 1/2” ALUMINUM INTEGRATED WITH MOUNTING

BRACKET AS REQUIRED. 3. SIGN PANEL TO BE 1/8” THICK PAINTED ALUMINUM PANEL IN COLOR INDICAT-

ED. ATTACH TO BACKGROUND PANEL IN A PERMANENT MANNER. 4. GRAPHICS TO BE 1/4” THICK FLAT CUT OUT PAINTED ALUMINUM ADHERED TO

SIGN PANEL WITH EPOXY AND ALIGNMENT PINS OR HIDDEN FASTENERS. 5. ALUMINUM MOUNTING BRACKET WITH WELDED CONSTRUCTION AS REQUIRED.

ATTACH TO CEILING WITH FLAT-HEAD/COUNTERSUNK FASTENERS AS REQUIRED.

6. FIELD VERIFY EXISTING CONDITIONS PRIOR TO FABRICATION OF SIGNS.

COORDINATE WITH G.C. AND DETERMINE BEST METHOD FOR INSTALLATION REQUIREMENTS.

7. LAWA TO PROVIDE SIGN LOCATIONS AND SPECIFIC MESSAGE PER SIGN

LOCATION.

8. A MINIMUM VERTICAL CLEARANCE OF 6’-8” AFF ON ELEVATION.

BACKGROUND PANEL 2.

SIGN PANEL 3.

BLOCKING 6.

MOUNTING BRACKET 5.

GRAPHICS 4

6'-8

" MIN

. AFF

1 5/8"

3"

6"

1'-4"1'-6"

1'-4"

1'-6"

FINISHED FLOOR

CEILING

1/2"

30

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Counter IdentityG_5

Sign Type Design

FRONT ELEVATION1 SCALE: 1 1/2” -= 1’-0”SECTION DETAIL2 SCALE: 3” -= 1’-0”

GENERAL NOTES: 1. FABRICATED ALUMINUM NUMBERS. 2. NUMBERS TO BE FABRICATED ALUMIUM WITH ALL SURFACES PAINTED IN

COLOR NOTED. NUMBERS TO BE MOUNTED TO 3/16” THICK ALUMINUM BASE PLATE.

3. ATTACH SIGNAGE TO FACILITY GATE PODIUM WITH COUNTERSUNK MECHANI-

CAL FASTENERS AS REQUIRED. 4. FIELD VERIFY EXISTING CONDITIONS. COORDINATE WITH GENERAL CONTRAC-

TOR TO DETERMINE BEST METHOD OF INSTALLATION BASED ON STRUCTURAL ENGINEERING CALCULATIONS.

5. LAWA TO PROVIDE LOCATIONS AND SPECIFIC MESSAGES PER SIGN LOCATION. 6. A MINIMUM VERTICAL CLEARANCE OF 6’-8” AFF ON ELEVATION.

TVDISPLAY

TVY

FINISHED FLOOR

6'-8

" MIN

. AFF

31

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

TSA Identity Blade G_6

Sign Type DesignGENERAL NOTES: 1. FREESTANDING, NON-ILLUMINATED, DOUBLE-FACED FABRICATED PYLON

IDENTITY. 2. PYLON TO BE FABRICATED ALUMINUM CONSTRUCTION WITH BRUSHED FINISH. 3. SIGN PANEL TO BE 1/8” THICK PAINTED ALUMINUM PANEL PERMANENTLY

ADHERED TO PYLON. 4. NUMBER TO BE FLAT-CUT-OUT 22 GUAGE ALUMINUM WITH FACE AND EDGES

PAINTED IN COLOR NOTED. 5. RULE LINE TO BE MASKED AND SPRAY PAINTED OR SCREEN PRINTED. 6. FIELD VERIFY EXISTING CONDITIONS. COORDINATE WITH GENERAL

CONTRACTOR TO DETERMINE BEST METHOD OF INSTALLATION BASED ON STRUCTURAL ENGINEERING CALCULATIONS.

7. LAWA TO PROVIDE LOCATIONS AND SPECIFIC MESSAGES PER SIGN

LOCATION. 8. LAWA TO PROVIDE OVERALL SIGNAGE DIMENSIONS.

FRONT ELEVATION1 NOT TO SCALE

SIGN PANEL 3

NUMBERS 4

PYLON 2

4 1/2"10 1/4"

9"

1/2" 1/2"

1 3/4"

6'-10" 5'-11 3/4"

2"

2"

RULE LINE 5

32

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Room Occupancy

Sign Type Design

M_1

CONTEXT ELEVATION3 NOT TO SCALE

GENERAL NOTES: 1. WALL MOUNTED PLAQUE WITH PAINTED BACKGROUND AND SCREENED

GRAPHICS. 2. SIGN PANEL TO BE 1/8” THICK BRUSHED ALUMINUM WITH MASKED AND

PAINTED BACKGROUND. 3. COPY TO BE 3M MATTE WHITE OPAQUE FILM MACHINE CUT VINYL AS

INDICATED ON DRAWING. 4. FLUSH MOUNT ONTO EXISTING INTERIOR WALL WITH SILICONE ADHESIVE AND

VHB TAPE AS REQUIRED. 5. LAWA TO PROVIDE SPECIFIC MESSAGE PER LOCATION OF SIGN.5'

-6"

5'-0"

C L 75PERSONS

MAXIMUMOCCUPANCY

NOT TO EXCEED

FRONT ELEVATION1 NOT TO SCALESIDE ELEVATION2 NOT TO SCALE

10" 9 1/2"

3/4"5/8"

1/2"

10"

9 1/2"

OF SIGN & COPYC L

C L

4

3/4"

5/8"

5/8"3/4"

3/4"

5/8"

3"

1/2"

33

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Life Safety Regulation Identity M_2

Sign Type Design

CONTEXT ELEVATION3 NOT TO SCALE

Jambs of Elevator Hoistway Entrance

ELEVATOR HOISTWAY SIGN

GENERAL NOTES: 1/8” THICK STAINLESS STEEL PANEL WITH SCREENPRINTED GRAPHICS.

INLAYED 1/32“ D. DIMENSIONAL LETTERS TO BE 1/16” THICK PAINTED AS NOTED.

MOUNT TO WALL WITH SPACER PANEL (THICKNESS DETERMINED BY EXISITING CALL BUTTON PANEL), VHB TAPE AND SILICONE ADHESIVE.

BRAILLE TO BE GRADE 2 STAINLESS STEEL BEADS.

REFER TO MESSAGE SCHEDULE FOR EXACT MESSAGE PER LOCATION OF SIGN.

WIDTH IS DETERMINED BY WIDTH OF ELEVATOR CALL BUTTON PANEL. CONFIRM PRIOR TO FABRICATION OF SIGN.

FIELD VERIFY PRIOR TO FABRICATION.

NOTE: THIS SIGN IS NOT REQUIRED, NOR SHOULD IT BE PROVIDED AT ELEVATORS

THAT SERVE AS AN ACCESSIBLE MEANS OF EGRESS (CBC 3002.3, EXCEPTION 1), OR AT ELEVATORS THAT ARE USED FOR OCCUPANT SELF-EVACUATION IN ACCORDANCE WITH CBC 3008 (CBC 3002.3, EXCEPTION 2).

1.

2.

3.

4.

5.

6.

7.

SIDE ELEVATION2 NOT TO SCALE

PICTOGRAM FIELD 1 2"

3 3/

8"

4 3/8"

C L

FRONT ELEVATION1 NOT TO SCALE

5"± VERIFY

2 1/8"

5/16"3/16"5/16"3/16"5/16"3/16"5/16"3/16"5/16"

11/16"

9"5/8"

3 1/4"

C L

IN FIREEMERGENCY,DO NOT USEELEVATOR

USE EXIT STAIRS

34

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

01-30-2018

Evacuation Plan ElevatorM_3

Sign Type Design

GENERAL NOTES: 1. EVACUATION PLAN REGULATION SIGNAGE. 2. SIGN BACKGROUND TO BE 1/8” THICK ALUMINUM WITH BRUSHED FINISH ON FACE AND EDGES. 3. 1/8” THICK PAINTED ACRYLIC SIGN PANEL TO BE ADHERED TO SIGN BACKGROUND IN A PERMANENT MANNER. 4. ALL COPY AND GRAPHICS TO BE SCREEN PRINTED IN COLORS INDICATED. 5. FLUSH MOUNT TO EXISTING WALL WITH WELDED THREADED STUDS AND SILICONE ADHESIVE AS REQURIED. 6. LAWA TO PROVIDE BASE MAP ART AND SPECIFIC MESSAGES PER LOCATION OF SIGN.

FRONT ELEVATION - ALT 11 NOT TO SCALE

CONTEXT ELEVATION3 NOT TO SCALE

RE

CO

MM

EN

DE

DH

EIG

HT

ATTACHED SIGNS

FINISHED FLOOR

SIDE ELEVATION2 NOT TO SCALE

PICTOGRAM

PICTOGRAM

4

4

SIGN PANEL 3

1’-1”

2”

1/4”OF SIGN & COPYC L

NUMBERS

COPY

RULE

4

4

4

COPY 4

COPY

1/4”

1/4”

1/2”

1/2”

1/2”

1/2”

3/8”

3/8”

3/8”

3/8”1/2”

3/8”1/2”

1/16”

1/16”1’-6”

1/4”

3/4”

1/4”3/8”

3”

3/8”

1/2”3/8”

5/8”

7/8”

3/4”

3/4”

1/2”3/8”

PICTOGRAM

PICTOGRAM

4

CONTEXT ELEVATION6 NOT TO SCALE

FRONT ELEVATION - ALT 25 NOT TO SCALE

FRONT ELEVATION3 NOT TO SCALESIDE ELEVATION4 NOT TO SCALE

BACKGROUND PANEL

SIGN PANEL

BRAILLE

DIMENSIONAL LETTERS

1/8”

1/8”1’-0”

4”

11 1/2”

1/2"

3/8"

7/8"

7/8"

2

1

SIGN PANEL 1 2

6

3

PICTOGRAM

PICTOGRAM

4

4

SIGN PANEL3

NUMBERS

COPY

RULE

4

4 6

4

COPY4 6

PICTOGRAM

PICTOGRAM

1’-1”

2”

1/4”OF SIGN & COPYC LCOPY

1/4”

3/4”

1/4”3/8”

3”7/8”

1/2”3/8”

4

1/4”

1/2”1/2”

1/2”

1/2”

1 1/4”

3/8”1/4”3/8”

3/8”

1/2”3/8”

1/2”3/8”

1/2”3/8”

1/2”3/8”

7/8”3/8”

1/4”3/8”1/4”3/8”

1/16”

1/16”

1’-6”

3/8”

1/2”3/8”

5/8”

3/4”

3/4”

EVACUATION PLAN300 WORLD WAY - LEVEL 3

Emergency Phone Number: 911Fire alarm sounds like a loud tone.Fire alarm looks like �ashing light.

Fire Extinguisher

Fire PullYou Are Here

Elevator Stairwell

Exit Route

IN CASE OF FIRE USE EXIT STAIRSDO NOT USE ELEVATOR

T3 - St.#5EVACUATION PLAN

300 WORLD WAY - LEVEL 3

Emergency Phone Number: 911Fire alarm sounds like a loud tone.Fire alarm looks like �ashing light.

Fire Extinguisher

Fire PullYou Are Here

Elevator Stairwell

Exit Route

IN CASE OF FIRE USE EXIT STAIRSDO NOT USE ELEVATOR

T3 - St.#5

EVACUATION PLAN300 WORLD WAY - LEVEL 3

Emergency Phone Number: 911Fire alarm sounds like a loud tone.Fire alarm looks like �ashing light.

Fire Extinguisher

Fire Pull

You Are Here

Elevator

Stairwell

Exit Route

IN CASE OF FIREUSE EXIT STAIRSDO NOT USEELEVATOR

T3 - St.#5

35

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Elevator Directory M_4

Sign Type DesignGENERAL NOTES: 1. WALL MOUNTED PLAQUE WITH PAINTED BACKGROUND AND SCREENED

GRAPHICS. 2. SIGN PANEL TO BE 1/8” THICK BRUSHED ALUMINUM WITH MASKED AND

PAINTED BACKGROUND. 3. COPY AND GRAPHICS TO BE MACHINE CUT VINYL ON INDIVIDUAL CHANGEABLE

PANELS WITH COLOR TO MATCH AS INDICATED ON DRAWING. 4. FLUSH MOUNT ONTO EXISTING INTERIOR WALL WITH SILICONE ADHESIVE AND

VHB TAPE AS REQUIRED. 5. LAWA TO PROVIDE SPECIFIC MESSAGE PER LOCATION OF SIGN.

FRONT ELEVATION1 NOT TO SCALE

SIDE ELEVATION2 NOT TO SCALE

11/16"11/16"

3/8"

9/16"

9/16"9/16"

9/16"

3"4 1/2"

1/8"

2 7/8"

2 7/8"

2 7/8"

2 7/8"

2 7/8"

1'-8"

1 3/4"

3/4"

3/4"

11/16"1 3/32"

1 3/32"

FIRST CLASS BOARDINGU.S. CUSTOMS

LEVEL 4GENERAL BOARDINGRESTROOMS

AUTHORIZED ACCESS ONLY

543

FIRST CLASS BOARDINGU.S. CUSTOMS

LEVEL 4

AUTHORIZED ACCESS ONLY

5

3

GENERAL BOARDINGRESTROOMS4

5'-1

0" M

AX

36

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Stairwell IdentityM_5

Sign Type DesignGENERAL NOTES: 1. ADA AND LOCAL FIRE CODE COMPLIANT WALL MOUNTED IDENTIFICATION

PANEL. 2. BACKGROUND PANEL TO BE 4MM SINTRA FINISH ON FACE AND EDGES. 3. SIGN PANEL TO BE 1/8” THICK PHOTOPOLYMER PANEL. 4. FLUSH MOUNT ONTO EXISTING INTERIOR WALL WITH SILICONE ADHESIVE AND

VHB TAPE AS REQUIRED. 5. VERIFY WITH LAWA FOR SPECIFIC MESSAGES PER SIGN LOCATION. CONTEXT ELEVATION4 SCALE: 3/16” = 1’-0”

TOP OF SIGN

1'-9"

1'-8 1/2"

1'-7"

1"

1 1/2"

7/8"

1 1/2"

1 1/4"

6"

OF SIGN & COPYC L

C L

1 1/2"

7/8"

1 1/2"

1 1/2"

1 1/4"

DIMENSIONALLETTERS

1/8”

BACKGROUNDPANEL2

SIGN PANEL3

NUMBER

FRONT ELEVATION1 NOT TO SCALESIDE ELEVATION2 NOT TO SCALE

STAIR 5NO ROOF ACCESS

2EXIT AT LEVEL 1

1 THRU 5

37

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

01-30-2018

Stair Identity M_6

Sign Type Design

3” Space from Door Frame

5

4’R

EC

OM

ME

ND

ED

HE

IGH

T

ATTACHED SIGNS

FINISHED FLOOR

CONTEXT ELEVATION6 NOT TO SCALE

GENERAL NOTES: 1. EVACUATION PLAN REGULATION SIGNAGE. 2. SIGN BACKGROUND TO BE 1/8” THICK ALUMINUM WITH BRUSHED FINISH ON FACE AND EDGES. 3. 1/8” THICK PAINTED ACRYLIC SIGN PANEL TO BE ADHERED TO SIGN BACKGROUND IN A PERMANENT MANNER. 4. ALL COPY AND GRAPHICS TO BE SCREEN PRINTED IN COLORS INDICATED AS

SHOWN ON 3. 5. FLUSH MOUNT TO EXISTING WALL WITH WELDED THREADED STUDS AND SILICONE ADHESIVE AS REQURIED. 6. LAWA TO PROVIDE BASE MAP ART AND SPECIFIC MESSAGES PER LOCATION OF SIGN.

NOTE: SEE PAGE 51 FOR A REDUCE SIZE EVACUATION PLAN, ONLY IF WALL AREA

DOES NOT FIT THE SIZE OF THESE SIGNS.

FRONT ELEVATION - ALT 11 NOT TO SCALE

FRONT ELEVATION - ALT 25 NOT TO SCALE

SIDE ELEVATION2 NOT TO SCALEFRONT ELEVATION3 NOT TO SCALE

SIDE ELEVATION4 NOT TO SCALE

BACKGROUND PANEL

SIGN PANEL

BRAILLE

DIMENSIONAL LETTERS

1/8”

1/8”1’-0”

4”

11 1/2”

1/2"

3/8"

7/8"

7/8"

2

1

SIGN PANEL 1 2

6

3

EVACUATION PLAN300 WORLD WAY - LEVEL 3

Emergency Phone Number: 911Fire alarm sounds like a loud tone.Fire alarm looks like �ashing light.

Fire Extinguisher

Fire PullYou Are Here

Elevator Stairwell

Exit Route

IN CASE OF FIRE USE EXIT STAIRSDO NOT USE ELEVATOR

T3 - St.#5

EVACUATION PLAN300 WORLD WAY - LEVEL 3

Emergency Phone Number: 911Fire alarm sounds like a loud tone.Fire alarm looks like �ashing light.

Fire Extinguisher

Fire PullYou Are Here

Elevator Stairwell

Exit Route

IN CASE OF FIRE USE EXIT STAIRSDO NOT USE ELEVATOR

T3 - St.#5

EVACUATION PLAN300 WORLD WAY - LEVEL 3

Emergency Phone Number: 911Fire alarm sounds like a loud tone.Fire alarm looks like �ashing light.

Fire Extinguisher

Fire Pull

You Are Here

Elevator

Stairwell

Exit Route

IN CASE OF FIREUSE EXIT STAIRSDO NOT USEELEVATOR

T3 - St.#5

PICTOGRAM

PICTOGRAM

4

4

SIGN PANEL 3

1’-1”

2”

1/4”OF SIGN & COPYC L

NUMBERS

COPY

RULE

4

4

4

COPY 4

COPY

1/4”

1/4”

1/2”

1/2”

1/2”

1/2”

3/8”

3/8”

3/8”

3/8”1/2”

3/8”1/2”

1/16”

1/16”1’-6”

1/4”

3/4”

1/4”3/8”

3”

3/8”

1/2”3/8”

5/8”

7/8”

3/4”

3/4”

1/2”3/8”

PICTOGRAM

PICTOGRAM

4

PICTOGRAM

PICTOGRAM

4

4

SIGN PANEL3

NUMBERS

COPY

RULE

4

4 6

4

COPY4 6

PICTOGRAM

PICTOGRAM

1’-1”

2”

1/4”OF SIGN & COPYC LCOPY

1/4”

3/4”

1/4”3/8”

3”7/8”

1/2”3/8”

4

1/4”

1/2”1/2”

1/2”

1/2”

1 1/4”

3/8”1/4”3/8”

3/8”

1/2”3/8”

1/2”3/8”

1/2”3/8”

1/2”3/8”

7/8”3/8”

1/4”3/8”1/4”3/8”

1/16”

1/16”

1’-6”

3/8”

1/2”3/8”

5/8”

3/4”

3/4”

38

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Floor Identity M_7

Sign Type DesignGENERAL NOTES: 1. ADA AND LOCAL FIRE CODE COMPLIANT WALL MOUNTED IDENTIFICATION

PANEL. 2. BACKGROUND PANEL TO BE STAINLESS STEEL WITH BRUSHED FINISH ON

FACE AND EDGES. ADHERE TO PHOTOPOLYMER PANEL IN A TAMPERPROOF MANNER.

3. SIGN PANEL TO BE 1/8” THICK PHOTOPOLYMER PANEL. 4. SIGN TO BE FLUSH MOUNTED TO WALL WITH THREADED WELDED STUDS AND

SILICONE ADHESIVE AS REQUIRED.

5. PHOTOPOLYMER BRAILLE TO BE GRADE 2 AND PAINTED TO MATCH BACKGROUND COLOR

6. VERIFY WITH LAWA FOR SPECIFIC MESSAGES PER SIGN LOCATION.

NOTE: THE STAR INDICATE THE ACTUAL DISCHARGE LEVEL VARIES.

CONTEXT ELEVATION4 SCALE: 3/16” = 1’-0”

TOP OF SIGN

STAIR 5NO ROOF ACCESS

1EXIT THIS LEVEL

1 THRU 5���� ���� �����

STAIR 5NO ROOF ACCESS

1EXIT THIS LEVEL

1 THRU 5���� ���� �����

1'-9"

1'-8 1/2"

1'-9"

1"

1 1/2"

1 3/8"

1 1/2"

3/4"

1 1/2"

6"

OF SIGN & COPYC L

C L

1 1/2"

3/4"

1 1/2"

1/2"

1 7/8"

1"

DIMENSIONALLETTERS

BACKGROUNDPANEL2

SIGN PANEL

BRAILLE

3

NUMBERSTAR

ATTACHED SIGNTO WALL4

FRONT ELEVATION1 NOT TO SCALESIDE ELEVATION2 NOT TO SCALE

39

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Area of Assistance Sign M_8

Sign Type DesignGENERAL NOTES: 1. ADA COMPLIANT WALL MOUNTED IDENTIFICATION PANEL. 2. SIGN BACKGROUND TO BE 1/8” THICK ALUMINUM WITH BRUSHED FINISH ON

FACE AND EDGES. ADHERE TO PHOTOPOLYMER PANEL IN A TAMPERPROOF MANNER.

3. COPY AND GRAPHICS TO BE SCREEN PRINTED IN COLORS INDICATED. 4. MAP TO BE SCREEN PRINTED IN COLORS INDICATED. MAP TO BE UNIQUE PER

SIGN LOCATION. MAP SHOWN IS FOR REFERENCE ONLY. MAP ART TO BE PROVIDED BY GENERAL CONRACTOR.

5. SIGN TO BE FLUSH MOUNTED TO WALL WITH THREADED WELDED STUDS AND

SILICONE ADHESIVE AS REQUIRED. 6. SIGNAGE SHOWN IS FOR PLACEMENT PURPOSES ONLY. LAWA TO PROVIDE

MESSAGE SCHEDULE FOR SPECIFIC MESSAGES PER SIGN LOCATION.

Key Plan

2"

1/2"

1/2"

1 1/2"

6"1'-7"

1 1/2"

3/4"

1/2"3/4"

2"

1"

1"

1"

ATTACH TO WALLAS REQUIRED 5

2GROUND PANELPANEL 1

FRONT ELEVATION2 NOT TO SCALESIDE ELEVATION3 NOT TO SCALE

FRONT ELEVATION1 NOT TO SCALE

Stair 1No Roof Access

Stair 6No Roof

EVAC MAP TBD

Access

1/4"

1/4"

1'-7"

1'-4"1'-0"

1/4" 1/4"

1/8"

1/8"1/4" 1/4" OF SIGN & COPYC L

5 1/4"

6 7/8"

5/8"1/2"

1/16"1/2"

5/8"

5/8"

5/8"

5/8"

3/4"

1/2"

1/4"

5/8"1/4"

5/8"1/4"

1/2"1/2"

1/4"

1/4"

OF SIGN & COPYC L

COPY 4 6

COPY 4COPY 3

SIGN PANEL

COPY 4

COPY 4 6

5/8"

1/2"

5/8"1/2"5/8"3/2"

3

3 PICTOGRAM

PICTOGRAM

PICTOGRAMBACKGROUND

AREA FOREVACUATIONASSISTANCE

FOR ASSISTANCEUSE PHONE

Key Plan

Persons able to use stairway, doso as soon as possible.

Emergency communications system is available 24 hours a day by using phone for assistance.

Stair 1No Roof Access

Stair 6No Roof

EVAC MAP TBD

Access

380 WORLD WAY - LEVEL 3

Stairwell

Fire PullFire ExtinguisherArea of EvacuationAssistance

You Are HereExit RouteElevator

40

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

01-30-2018

Area of Evacuation Map/Stair IdentityM_9

Sign Type Design

FRONT ELEVATION1 NOT TO SCALESECTION DETAIL2 NOT TO SCALE

10"1/2"

3/8"

5/8"3/8"

3/8"3/8"

1/4"

7/8"

7/8"

7/8"

3/8"

7/8"

7/8"

3/8"

1/4"3/4"

3/4"1/8"

AREA FOREVACUATIONASSISTANCE

AREA FOREVACUATIONASSISTANCE

GENERAL NOTES: 1. TWO PART FABRICATED ALUMINUM AND ACRYLIC SIGN PANEL WITH INTERNAL

ILLUMINATION, RECESS INTO WALL. 2. “UPPER PANEL” TO BE TRANSLUCENT ACRYLIC WITH OPAQUE PAINTED OR

VINYL FIELD WITH SHOW-THRU INTERNALLY ILLUMINATED COPY AND ACCESSIBLE LOGO. ILLUMINATION TO MEET CODE REQUIREMENTS FOR THIS SIGN. PROVIDE INCONSPICUOUS MAINTENANCE ACCESS.

3. “LOWER PANEL” TO BE BRUSHED ALUMINUM PANEL WITH PAINTED FIELD.

COPY AND GRAPHICS TO BE SCREEN PRINTED IN COLORS INDICATED. 4. ADA COPY TO BE DIMENSIONAL AND PAINTED IN COLOR NOTED. ADA COPY TO

MEET ADA REQUIREMENTS. 5. 120V CIRCUIT AND BATTERY BACK-UP AS REQUIRED FOR LOW VOLTAGE LED

POWER SUPPLY. 6. COORDINATE WITH GENERNAL CONTRACTOR TO PROVIDE WALL RECESS ABD

ELECTRICAL FEED AS REQUIRED. 7. BRAILLE TO BE GRADE 2 WITH COLOR TO MATCH BACKGROUND. 8. MESSAGE SHOWN IS FOR PLACEMENT PURPOSES ONLY. LAWA TO PROVIDE

SPECIFIC MESSAGES PER LOCATION OF SIGN. 9. SIGN TO BE FLUSH MOUNTED ONTO EXISTING FACILITY WALL IN A

TAMPER-PROOF MANNER.

NOTE: ALL TEXT MUST COMPLY WITH THE ADA STANDARDS, INCLUDING FONT SIZE,

COLOR CONTRAST AND READABILITY FROM A DISTANCE.

SEE PAGE 51 FOR A REDUCE SIZE EVACUATION PLAN, ONLY IF WALL AREA DOES NOT FIT THE SIZE OF THESE SIGNS.

FRONT ELEVATION - ALT 13 NOT TO SCALESIDE ELEVATION4 NOT TO SCALE

9 1/2"

9"

PICTOGRAM

PICTOGRAM

4

4

SIGN PANEL 3

1’-1”

2”

1/4”OF SIGN & COPYC L

NUMBERS

COPY

RULE

4

4

4

COPY 4

COPY

1/4”

1/4”

1/2”

1/2”

1/2”

1/2”

3/8”

3/8”

3/8”

3/8”1/2”

3/8”1/2”

1/16”

1/16”1’-6”

1/4”

3/4”

1/4”3/8”

3”

3/8”

1/2”3/8”

5/8”

7/8”

3/4”

3/4”

1/2”3/8”

PICTOGRAM

PICTOGRAM

4

EVACUATION PLAN300 WORLD WAY - LEVEL 3

Emergency Phone Number: 911Fire alarm sounds like a loud tone.Fire alarm looks like �ashing light.

Fire Extinguisher

Fire PullYou Are Here

Elevator Stairwell

Exit Route

IN CASE OF FIRE USE EXIT STAIRSDO NOT USE ELEVATOR

T3 - St.#5

41

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Tactile Exit – Wall M_10

Sign Type Design

FRONT ELEVATION1 NOT TO SCALE

SIDE ELEVATION2 NOT TO SCALE

9 1/2"

4 1/

4"

1 3/

8"5/

8"3/

8"3/

8"1

1/2"

(3/8

" MIN

.)

9"

C L

���� �����

GENERAL NOTES: 1. TACTILE WALL MOUNTED IDENTIFICATION PANEL. 2. SIGN BACKGROUND TO BE 1/8” THICK ALUMINUM WITH BRUSHED FINISH ON FACE AND

EDGES. ADHERE TO PHOTOPOLYMER PANEL IN A TAMPERPROOF MANNER. 3. SIGN PANEL TO BE 1/8” THICK PHOTOPOLYMER PANEL WITH 1/32” RAISED GRAPHICS WITH

BRAILLE. 4. PHOTOPOLYMER ADA COMPLIANT LETTERS TO BE MINIMUM 1/32” PROTRUSION FROM FACE

OF SIGN AND SCREEN TIPPED IN COLOR NOTED. 5. PHOTOPOLYMER BRAILLE TO BE GRADE 2 AND PAINTED TO MATCH BACKGROUND. 6. SIGN TO BE FLUSH MOUNTED TO WALL WITH THREADED WELDED STUDS AND SILICONE

ADHESIVE AS REQUIRED. 7. PROVIDE SIGNAGE IN REQUIRED AREAS WITH PROPER MESSAGING PER ADA AND LOCAL

CODES.

NOTE: CA-COMPLIANT GRADE 2 BRAILLE BY A CERTIFIED GRADE 2 BRAILLE TRANSLATOR.

42

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Exit Only No Re-EntryM_11

Sign Type Design GENERAL NOTES: 1. DOOR MOUNTED ALUMINUM SIGN PANEL WITH SCREEN PRINTED COPY AND

SMBOLS, 2. SIGN PANEL TO BE 1/16” THICK BRUSHED ALUMINUM WITH PANTED CENTER. 3. COPY, GRAPHICS AND BACKGROUND FIELD TO BE MASKED AND PAINTED OR

SCREENPRINTED. 4. MOUNT TO DOOR WITH VHB TAPE AND SILICONE ADHESIVE AS REQUIRED. FOR

GLASS DOOR INSTALLATIONS ADHERE WHITE VINYL CUT TO SIGN PANEL PROPORTIONS TO FIRST SURFACE OF GLASS PRIOR TO INSTALLATION OF SIGN PANEL.

5. CONFIRM MESSAGING WITH LAWA PRIOR TO FABRICATION OF SIGNS.

NOTE: MINIMUM TEXT HEIGHT 5/8”.

FRONT ELEVATION1 NOT TO SCALESIDE ELEVATION2 NOT TO SCALE

SYMBOL BORDER 3

SYMBOL 3

SYMBOL BACKGROUND 3

PAINTED SIGN PANEL 2

EXIT ONLYNO RE-ENTRY

1'-0"

1 3/4"

1 1/8"1/4"

1 1/2"

3/4"

3/4"

5/8"5"

COPY 3

EXIT ONLYNO RE-ENTRY

43

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Restricted Area – Door M_12

Sign Type Design

1'-4"

3/16"

3/16"

2"

7"

3/4"

7/8"

1 1/8"

3/4"

1/2"

1"

1"

1"

1'-4"

3/16"

3/16"

2"

1'-0"

3/4"

7/8"

3/4"

1/2"

1/4"

1/4"

1/4"1/4"

1/4"

1/4"1/4"

1/4"

1/4"

5/8"

5/8"

5/8"

5/8"

5/8"

5/8"

5/8"

5/8"

5/8"

5/8"5/8"

1'-4"

3/16"

3/16"

2"

1'-1/2"

3/4"

7/8"

3/4"

1/2"

1/2"1/2"

5/8"

5/8"

5/8"

5/8"

5/8"

5/8"

5/8"

5/8"

3/8

3/4"

5/8"

1/4"

1/4"

1/4"

1/4"

1/4"

1/4"

1/4"

1/4"

1'-4"

3/16"

3/16"

2"

8 1/2"

3/4"

7/8"

3/4"

3/4"

1/4"

1/4"

1/4"3/8"

5/8"

5/8"

3/4"

3/4"

1/2"

1/2"1/2"

RESTRICTED AREA

L.A.M.C. 56.30 L.A. CITY ORDINANCE NO. 95-789

TRESPASSING / LOITERINGPROHIBITED BY LAW

ALL AUTHORIZED PERSONNEL MUSTDISPLAY ID BADGE BEYOND THIS POINT

1'-4"

3/16"

3/16"

2"

7"

3/4"

7/8"

3/4"

7/8"

1/4"5/8"

5/8"

3/4"

1/2"

1/2"1/2"

1'-4"

3/16"

3/16"

2"

1'-3 1/2"

3/4"

7/8"

3/4"

1/4"

1/4"

1/4"3/8"

5/8"

5/8"

3/4"

3/4"

1/2"

1/2"

1/2"1/2"

1/2"

3/4"

1"

1"

COPY, TYP.

LINE

LAYOUT “A”1 NOT TO SCALE

LAYOUT “B”2 NOT TO SCALE

LAYOUT “C”3 NOT TO SCALE

LAYOUT “D”4 NOT TO SCALE

LAYOUT “E”5 NOT TO SCALE

LAYOUT “F”6 NOT TO SCALE

CONTEXT ELEVATION7 NOT TO SCALE

FINISHED FLOOR

GENERAL NOTES: 1. SCREENPRINTED GRAPHICS ON OPAQUE WHITE VINLY FILM WITH ADHESIVE

BACKING.

2. MOUNT TO FACE OF EXISTING FACILITY DOOR. GLASS DOOR INSTALLATIONS TO HAVE WHITE POLYESTER FILM PROFILE CUT TO MATCH SIGN, ATTACH TO SECOND SURFACE OF GLASS. COLOR TO MATCH RED.

3. REFER TO LAWA FOR EXACT MESSAGE PER LOCATION OF SIGN.

4. COPY AND SYMBOLS TO BE SCREENPRINTED, COLOR AS INDICATED.

5. LAYOUT “A” TO BE ORDERED THROUGH U.S. CUSTOMS BORDER PROTECTION SEAL TO BE PRINTED BY U.S. CUSTOMS BORDER PROTECTION APPROVED PRINTER ONLY.

44

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Poster Frame

Sign Type Design

M_13

FRONT ELEVATION1 NOT TO SCALESIDE ELEVATION2 NOT TO SCALE

N.I.C.

6'-1

0"

45

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

08-04-2015

Sign Type Design

Poster Stanchion M_14

FRONT ELEVATION1 NOT TO SCALE

DETAIL2 NOT TO SCALE

GENERAL NOTES: 1. FREESTANDING PORTABLE POSTER STANCHION. 2. 22”X28” DIRECTRAC CURVED BASE, WITH DIRECTRAC POSTER CARTRIDGE.

CATALOG NUMBER #50-4501A/SA/SET, SATIN ALUMINUM FINISH. PRE-AP-PROVED FOR TSA USAGE.

LAVI INDUSTRIES, LAVI.COM 27810 AVENUE HOPKINS VALENCIA, CA 91355 [email protected] PHONE: (888) 285-8605 3. TSA TO PROVIDE POSTER INSERTS.

1'-10"2’

-4”

46

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

08-04-2015

FRONT ELEVATION1 NOT TO SCALE

DETAIL2 NOT TO SCALE

GENERAL NOTES: 1. FREESTANDING PORTABLE POST STANCHION. 2. 22" X 28" VERTICAL TRADITIONAL SIGN

3. 72" POSTS STAND WITH SLOPED BASE, SATIN ALUMINUM FINISH. PRE-APPROVED FOR TSA USAGE.

LAVI INDUSTRIES, LAVI.COM 27810 AVENUE HOPKINS VALENCIA, CA 91355 [email protected] PHONE: (888) 285-8605 4. AIRLINES TO PROVIDE POSTER INSERTS.

NOTE: IF SIGNS / POSTERS ON THESE STANCHIONS PROVIDE DIRECTION TO

OR INFORMATION ABOUT INTERIOR OR EXTERIOR SPACES AND FACILITIES, THEY MUST COMPLY WITH ACCESSIBILITY REQUIREMENTS (CBC 11B-216.3). MOST NOTABLY, SINCE THIS STANCHION IS QUITE TALL, CHARACTERS LOCATED > 70" AFF (TO </= 120" AFF) MEASURED TO THEIR BASELINE MUST BE AT LEAST 2" TALL DEPENDING ON VIEWING DISTANCE (CBC 11B-703.5.5).

SPECIALSERVICES

1'-10"

2’-4

”6’

-0”

Sign Type Design

Poster StanchionM_15

47

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Sign Type Design

Clearance Path M_16

FRONT ELEVATION1 NOT TO SCALE

GENERAL NOTES: 1. PAINTED GRAPHIC ONTO FLOOR SURFACE. 2. PAINT TO BE SLIP RESISTANT 3. LAWA TO PROVIDE LOCATIONS OF SIGNS.

2.

COPY 2.

3'-0"

17'-6"

6'-2"

7"

KEEPCLEAR

48

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

04-07-2017

GENERAL NOTES: 1. WALL MOUNTED SIGN PANEL. 2. SIGN PANEL TO BE PAINTED ALUMINUM WITH REFLECTIVE VINYL GRAPHICS. 3. MOUNT TO WALL WITH VHB TAPE AND SILICONE ADHESIVE AS REQUIRED. 4. VERIFY LOCATIONS, MESSAGING AND QUANTITIES WITH LAWA.

5. 5/8” MINIMUM TEXT HEIGHT.

5"5/8"

1"

1/4"

3/8"

5/8"

1 7/8"

7/8"

1/2"

1'-2"

1’- 1 1/2"

FRONT ELEVATION1 NOT TO SCALE

KEEP AREA CLEARAT ALL TIMES

CAUTIONSign Type Design

Clearance Path – WallM_17

49

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Sign Type Design

Clearance Bar M_18

6. COORDINATE WITH GC FOR CLEARANCE HEIGHT DIMENSIONS.

7. 3” MINIMUM TEXT HEIGHT.

FRONT ELEVATION1 NOT TO SCALE

PLAN ELEVATION3 NOT TO SCALE

END ELEVATION2 NOT TO SCALE

CEILING STRUCTURE/MATERIAL

ENLARGED SUSPENSION DETAIL

INTERNAL STRUCTUREAS REQUIRED

9'-10"

REFLECTIVE VINYL LETTERING 4" CAP HT.

6" 4"1"

1"

50

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Clearance Bar

Clearance - Wall Mounted

Location

Dimensions

Location

Dimensions

M_21

M_22

12’ - 4” CLEARANCE

Freestanding Direction/Elev. Call

Location

Dimensions

M_23

5/8"

LEVEL 3level 3

IN FIRE EMERGENCY,DO NOT USE ELEVATOR

USE EXIT STAIRS

FIRE RECALL

FIREFIGHTER’S OPERATIONTO RECALL ELEVATORS INSERT FIRE

KEY AND TURN TO ON

Shopping

Restaurants

Restrooms

To All Gates

Terminal 3

Airline Lounge

Children’s Play Area

Smoking Lounge

Airline Lounge

Airline Lounge

CONTEXT ELEVATION2 NOT TO SCALE

DETAIL3 NOT TO SCALE

ATTACHED TO BUILDING STRUCTURE

1 1/2” X 1 1/2” SQUARE TUBE BRACKET ASREQUIRED. ATTACH TO BUILDING FACADEAND/OR TO TUBE SUPPORTS FOR SIGNTYPEMOUNTING BRACKET ATTACHED TOBUILDING SOFFIT WITH S/S HEX BOLT INTOEXPANSION ANCHOR; BOLT GOES THRUSOFFIT PANEL & RIGID INSULATION;EXPANSION ANCHOR & DRILLED HOLEIN SOFFIT PANEL BY GC;QTY. OF ANCHORS AS REQ’D.

NOTE: VERIFY SOFFIT CONSTRUCTION AT LOCATION.SECTION THRU PARKING STRUCTURE ENTRY SOFFIT

END VIEW

6” DIA. ALUMINUM TUBE CLEARANCEBAR SUSPENDED FROM SOFFITBANG BAR MOUNTED TO SOFFITCOORDINATE MOUNTINGREQUIREMENTS WITH GC.

(2) #6 x 1” S.S. PIN-IN-TORX FHSMS SCREW HEADS PAINTED TO MATCH BACKGROUND MMC# 95015A296

STEEL MOUNTING PLATE ATTACHED TO BUILDING STRUCTURE STEEL/CONCRETE ASSEMBLY. VERIFY ASSEMBLY REQUIREMENTS AND CONDITION PRIOR TO FABRICATION

CURTAIN WALL SYSTEM

VERIFY FULL WIDTH OF DRIVE AISLE FOR ASSEMBLY

13’-0”

GENERAL CONTRACTOR AND FABRICATORTO CONFIRM WEIGHT OF ASSEMBLY TO ENSURESTRUCTURAL SUPPORT IS ADEQUATE

FRONT ELEVATION1 NOT TO SCALE

1 1/2” X 1 1/2” SQUARE TUBE BRACKET ASREQUIRED. ATTACH TO BUILDING FACADEAND/OR TO TUBE SUPPORTS FOR SIGNTYPE

1"1"

4"

3. 3” MINIMUM TEXT HEIGHT.

Sign Type Design

Clearance – Wall MountedM_19

51

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Evacuation Plan Reduced Size M_20

Sign Type Design

FRONT ELEVATION - ALT 11 NOT TO SCALEFRONT ELEVATION - ALT 23 NOT TO SCALE

CONTEXT ELEVATION3 NOT TO SCALE

RE

CO

MM

EN

DE

DH

EIG

HT

SIDE ELEVATION2 NOT TO SCALE

1/4”

3/4”5/8”

3/8”3/8”

5/8”1/8”

1/2”

1/2”

1/16”

1/16”

3/8”

3/8”

3/8”

3/8”1/8”

3/8”1/8”

3/8”1/8”

1 3/8”

1/4”

1/4”5/8”

3/16”3/8”

2 1/4”

3/4”

3/8”3/8”3/8”3/8”3/8”3/8”3/8”3/8”3/8”3/8”3/8”

1/2”

PICTOGRAM

PICTOGRAM

4

4

SIGN PANEL3

NUMBERS

COPY

RULE

4

4 6

4

COPY4 6

PICTOGRAM

PICTOGRAM

1’-3”

11”

2 1/2”

1/4”OF SIGN & COPYC L

PICTOGRAM

PICTOGRAM

4

4

SIGN PANEL 3

11”

2 1/2”

1/8”OF SIGN & COPYC L

NUMBERS

COPY

RULE

4

4 6

4

COPY 4 6

COPY

5/8”1/8”

1/8”

1/2”

1/2”1/16”

1/16”1’-3”

1/4”

3/4”

3/16”3/8”

2 1/4”

3/8”

3/8”

3/8”3/8”

3/8”

3/8”

3/8”3/8”3/8”

1/4”

1/4”5/8”

5/8”

1/2”

1/2”

3/8”3/8”

PICTOGRAM

PICTOGRAM

4

GENERAL NOTES: 1. EVACUATION PLAN REGULATION SIGNAGE. 2. SIGN BACKGROUND TO BE 1/8” THICK ALUMINUM WITH BRUSHED FINISH ON FACE AND EDGES. 3. 1/8” THICK PAINTED ACRYLIC SIGN PANEL TO BE ADHERED TO SIGN BACKGROUND IN A PERMANENT MANNER. 4. ALL COPY AND GRAPHICS TO BE SCREEN PRINTED IN COLORS INDICATED. 5. FLUSH MOUNT TO EXISTING WALL WITH WELDED THREADED STUDS AND SILICONE ADHESIVE AS REQURIED. 6. LAWA TO PROVIDE BASE MAP ART AND SPECIFIC MESSAGES PER LOCATION OF SIGN.

NOTE: USE THIS REDUCE SIZE EVACUATION PLAN SIGN ONLY IF OTHER SIGNS ON

PAGE 34, 37, AND 40 DOES NOT FIT THE WALL AREA.

EVACUATION PLAN300 WORLD WAY - LEVEL 3

Emergency Phone Number: 911Fire alarm sounds like a loud tone.Fire alarm looks like �ashing light.

Fire Extinguisher

Fire PullYou Are Here

Elevator Stairwell

Exit Route

IN CASE OF FIRE USE EXIT STAIRSDO NOT USE ELEVATOR

T3 - St.#5

Emergency Phone Number: 911Fire alarm sounds like a loud tone.Fire alarm looks like �ashing light.

Fire Extinguisher

Fire Pull

You Are Here

Elevator

Stairwell

Exit Route

IN CASE OF FIREUSE EXIT STAIRSDO NOT USEELEVATOR

EVACUATION PLAN300 WORLD WAY - LEVEL 3

T3 - St.#5

52

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

GENERAL NOTES: 1. ADA COMPLIANT ROOM IDENTIFICATION SIGNAGE. 2. SIGN PANEL TO BE 1/4” THICK PHOTOPOLYMER MOUNTED TO WALL. 3. PHOTOPOLYMER DIMENSIONAL LETTERS TO BE MINIMUM 1/32” PROTRUSION

FROM SIGN FACE AND SCREEN-TIPPED IN COLOR INDICATED. 4. PHOTOPOLYMER GRADE 2 BRAILLE TO BE ADA COMPLIANT WITH COLOR TO

MATCH BACKGROUND COLOR. 5. SIGN TO BE MOUNTED TO WALL WITH VHB TAPE AND SILICONE ADHESIVE AS

REQUIRED. 6. COORDINATE WITH LAWA FOR SPECIFIC LOCATIONS AND MESSAGES PER

SIGN LOCATION.

NOTE: DUAL-PURPOSE SIGN MUST INCLUDE BOTH VISUAL AND TACTILE FORMATS.

SPACING BETWEEN THE BASELINES OF SEPARATE LINES OF CHARACTERS MUST BE 135% MINIMUM AND 175% MAXIMUM OF THE CHARACTER HEIGHT (CBC 11B-703.2.8). NEITHER A BASELINE-TO-BASELINE DIMENSION NOR A DIMENSION BETWEEN LINES OF RAISED TEXT IS PROVIDED.

CA-COMPLIANT GRADE 2 BRAILLE BY A CERTIFIED GRADE 2 BRAILLE TRANSLATOR.

2-1-CR01

Side Elevation2 NOT TO SCALE

Front Elevation2 NOT TO SCALE

5/8

5/8

5/8

5/8"

5/16

"3/

8"3/

8"7/

8"

3/8

5/16

"

1/4”

3/4"

1/2"

5/8"

6"

(NO COLOR)

VINYL NUMERALS(WHITE)

10-03-2017

Sign Type Design

Room IdentityR_1

53

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

GENERAL NOTES: 1. ADA COMPLIANT ROOM IDENTIFICATION SIGNAGE WITH REPLACEABLE NAME

PANELS. 2. SIGN PANEL TO BE 1/4” THICK PHOTOPOLYMER MOUNTED TO 1/8” THICK

ALUMINUM BACKGROUND PANEL. 3. BACKGROUND PANEL TO BE PAINTED ALUMINUM, PERMANENTLY ATTATCHED

TO SIGN PANEL AND REPLACEABLE PANEL EXTRUSION. 4. PHOTOPOLYMER DIMENSIONAL LETTERS TO BE MINIMUM 1/32” PROTRUSION

FROM SIGN FACE AND SCREEN-TIPPED IN COLOR INDICATED. 5. PHOTOPOLYMER GRADE 2 BRAILLE TO BE ADA COMPLIANT WITH COLOR TO

MATCH BACKGROUND COLOR. 6. PANEL GUIDES TO BE BRUSHED ALUMINUM REPLACEABLE PANEL EXTRUSION

OR FABRICATED AS REQUIRED. 7. REPLACEABLE PANELS TO BE PAINTED ACRYLIC WITH VINYL COPY. PANELS

TO BE HELD IN PLACE WITH HIDDEN FASTENERS. 8. SIGN TO BE MOUNTED TO WALL WITH THREADED WELDED STUDS AND

SILICONE ADHESIVE AS REQUIRED. 9. SIGNAGE SHOWN IS FOR PLACEMENT PURPOSES ONLY. LAWA TO PROVIDE

MESSAGE SCHEDULE FOR SPECIFIC MESSAGES PER LOCATION OF SIGNS. 10. 3/8” MINIMUM FOR BRAILLE HEIGHT.

NOTE: CA-COMPLIANT GRADE 2 BRAILLE BY A CERTIFIED GRADE 2 BRAILLE

TRANSLATOR.

FRONT ELEVATION1 NOT TO SCALESECTION DETAIL2 NOT TO SCALE

5/8"

5/8"

5/8"

5/8"

5/8"

5/8"

3/8"3/8"3/8"

7/8"

10 1/4"

3/4"

1/2"

1/4"

7/8"

1/4"

7/8"

1/4"

7/8"

1/4"

1/4"

1/8"

5/16"

5/16"

9 1/2"5/8"

1/4"1/8"

PANEL GUIDES 6

REPLACEABLE PANELS 7

REPLACEABLE PANEL COPY 7

SIGN PANEL 2

VINYL NUMBERALS(WHITE)

DIMENSIONAL LETTERS(NO COLOR)

ADA LETTERS 4

BRAILLE 5

5/8"

CBPTRAINING��� ��������

Mr. John Doe0ffcr. Jane Doe

2-1-CR012-1-CR01

Sign Type Design

Multiple Room Identity R_2

54

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

GENERAL NOTES: 1. DOUBLE-FACED, NON-ILLUMINATED WALL MOUNTED SIGN PANEL. 2. SIGN PANEL TO BE 1/4” THICK ALUMINUM WITH WHITE PAINTED FACE. 3. COPY AND PICTOGRAMS TO BE VINYL-DIE-CUT IN COLORS INDICATED. 4. FABRICATED ALUMINUM MOUNTING PLATE WITH BRUSHED FINISH. 5. ATTACH SIGN TO FACILITY WALL WITH STAINLESS STEEL COUNTERSUNK

FASTENERS AS REQUIRED. 6. VERIFY EXISTING CONDITIONS PRIOR TO FABRICATION OF SIGN. COORDINATE

WITH GENERAL CONTRACTOR TO PROVIDE ADDITIONAL BLOCKING AS REQUIRED.

6'-8

" MIN

.

MOUNTING PLATE2 NOT TO SCALEFRONT ELEVATION1 NOT TO SCALE

1’-4”

1”

3”

1”

1”

1”

7 1/2”

3/4”

3/4”

3/4”

5/8”

5/8”

1’-6”

1’-6”

10-03-2017

Sign Type Design

Defibrillator Identity BladeR_3

55

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

FRONT ELEVATION1 NOT TO SCALE

5’-1

0”

GENERAL NOTES: 1. PRINTED DECAL ON WHITE BACKGROUND. 2. VERIFY WALL CONDITIONS / BINNACLE PRIOR TO FABRICATION OF SIGN

1’-4”

3”

1

1

1

1

1

5/8”

3/4”

3/4”

3/4”

5/8”

1”

1’-6”

Sign Type Design

Defibrillator Identity Vinyl R_4

56

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

FRONT ELEVATION1 NOT TO SCALE

MOUNTING PLATE22

NOT TO SCALE

ADDITIONAL LAYOUTS6 NOT TO SCALE

SIGN PANEL 4

RESTROOMS

3 7

GENERAL NOTES: 1. DOUBLE-FACED, NON-ILLUMINATED, WALL MOUNTED BLADE SIGN. 2. FABRICATED ALUMINUM SIGN CABINET. 3. PICTOGRAMS TO BE FLAT-CUT OUT 1/4” THICK ALUMINUM PANITED IN COLORS

NOTED. PICTOGRAMS TO BE MOUNTED TO SIGN PANEL WITH HIDDEN MECHANI-CAL FASTENERS.

4. SIGN PANEL TO BE 1/4” THICK WITH FACE AND EDGES PAINTED IN COLOR AS

NOTED. 5. DESIGNER TO FIELD VERIFY AND DETERMINE BEST METHOD OF INSTALLATION

WITH MINIMAL VISUAL IMPACT. DESIGNER TO PROVIDE STRUCTURAL ENGINEER-ING CALCULATIONS AS REQUIRED AND COORDINATE WITH GENERAL CONTRAC-TOR FOR STRUCTURAL REQUIREMENTS.

6. ESTIMATED SIGN WEIGHT: 50 LBS EACH. 7. VERIFY SPECIFIC MESSAGE PER SIGN LOCATION WITH LAWA.

6'-8

"

CONTEXT ELEVATION5 NOT TO SCALE

HEARING LOSS

1'-3"

10 1

/4"

C L

TTY

1'-3"

10 1

/4"

C L

CLEAN AIR

1'-3"

10 1

/4"

C L

VOLUME CONTROL TELEPHONE

1'-3"

11"

C L

1'-3"

10 7

/8"

8"

C L

1 3/16”1 3/16”

1 15/16”

ALL GENDERRESTROOM

NURSING ROOM

PET AREAINFORMATION

5.

3”

SIDE CABINET

ELEVATORS

10 3

/4"

PUBLIC PHONECOURTESY PHONE

10 3

/4"

ESCALATORS

9 3/

8"

ATM

10 1

/2"

VENDING MACHINES

8 3/

8"

SMOKING

6 1/

8"

10-03-2017

Sign Type Design

General Services IdentityR_5

57

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

CIRCLE AND TRIANGLE SIGN PANELS TO BE 1/4” PHOTOPOLYMER WITH SILICONE ADHESIVS AND DOUBLE-SIDE TAPE.

FRONT ELEVATION MEN1 NOT TO SCALEFRONT ELEVATION WOMEN2 NOT TO SCALE

ALL GENDER3 NOT TO SCALESIDE VIEWS4 NOT TO SCALE

6. COORDINATE WITH LAWA FOR SPECIFIC LOCATIONS AND MESSAGES PER SIGN LOCATION.

CONTEXT ELEVATION5 NOT TO SCALE

4'-1

0" t

o 5

'-0"

12”12”

12”

Sign Type Design

Restroom Identity Door R_6

58

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

5'-0

" MA

X

4'-0

" MIN

ALL GENDERFAMILYWOMEN

3

4

3

4

3

2

3

2

2

GENERAL NOTES: 1. ADA COMPLIANT ROOM IDENTIFICATION SIGNAGE. 2. SIGN PANEL TO BE 1/8” THICK PHOTOPOLYMER. PAINT TO MATCH COLOR

INDICATED. 3. PHOTOPOLYMER DIMENSIONAL LETTERS TO BE MINIMUM 1/32” PROTRUSION

FROM SIGN FACE. LETTERS TO BE SCREEN-TIPPED IN COLOR INDICATED. 4. PHOTOPOLYMER CA-COMPLIANT GRADE 2 BRAILLE BY A CERTIFIED GRADE 2

BRAILLE TRANSLATOR WITH COLOR TO MATCH BACKGROUND COLOR. 5. SIGN TO BE MOUNTED TO WALL WITH THREADED WELDED STUDS AND

SILICONE ADHESIVE AS REQUIRED. 6. COORDINATE WITH LAWA FOR SPECIFIC LOCATIONS AND MESSAGES PER

SIGN LOCATION.

NOTE: SIGN MOUNTING HEIGHT IS NOT SHOWN OR NOTED. AS WITH ALL ROOM

IDENTIFICATION SIGNAGE, THESE SIGNS ARE REQUIRED TO BE MOUNTED NO LOWER THAN 48" AFF MEASURED TO THE BASELINE OF THE LOWEST LINE OF BRAILLE CELLS, AND NO HIGHER THAN 60" AFF MEASURED TO THE BASELINE OF THE HIGHEST LINE OF RAISED CHARACTERS. (CBC 11B-703.4.1).

FRONT ELEVATION1 NOT TO SCALESIDE ELEVATION2 NOT TO SCALE

ADDITIONAL LAYOUTS3 NOT TO SCALE

CONTEXT ELEVATION4 NOT TO SCALE

4"

1/8"

1/8"

5/8"

1 1/2"

3/8"

10-03-2017

Sign Type Design

Restroom Identity WallR_7

59

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

GENERAL NOTES: 1. ADA/TITLE 24 COMPLIANT ROOM IDENTIFICATION SIGNAGE. 2. SIGN PANEL TO BE 1/4” THICK PHOTOPOLYMER WITH PAINTED EDGE AND

BORDER. UNISEX VERSION TO BE PERMANENTLY MOUNTED TO BACKGROUND PANEL.

3. BACKGROUND PANEL FOR UNISEX VERSION ONLY TO BE PHOTOPOLYMER.

PAINT TO MATCH COLORS INDICATED. 4. PICTOGRAMS/LETTERS TO BE SCREEN PRINTED IN COLOR INDICATED. 5. SIGN TO BE MOUNTED TO WALL WITH THREADED WELDED STUDS AND

SILICONE ADHESIVE AS REQUIRED. 6. COORDINATE WITH LAWA FOR SPECIFIC LOCATIONS AND MESSAGES PER SIGN

LOCATION. NOTE: RAISED LETTERS AND BRAILLE ARE NOT REQUIRED, NOR SHOLD IT BE

PROVIDED ON THESE SIGNS, ESPECIALLY IF MOUNTED ON SWINGING DOORS.

FRONT VIEW-MEN/WOMEN4 NOT TO SCALEFRONT ELEVATION - ALL GENDER1 NOT TO SCALE

7/8"

1/2"

4"4"

9"

SCREEN PRINTED LETTERS

1'-0

"

SIDE VIEW - ALL GENDER2 NOT TO SCALESIDE VIEW - MEN/WOMEN3 NOT TO SCALE

BACKGROUNDBORDER 3

6

7/8"

4 1/

2"7/

8"3

3/8"

8 3/

4"

SCREEN PRINTED LETTERS

SIGN PANEL BORDER

BACKGROUND FIELD

1'-0

"

4

SCREEN PRINTED LETTERS

SIGN PANEL BORDER

BACKGROUND FIELD

4

7/8"

4 1/

2"7/

8"2

5/8"

8"

11 1

/2"

1'-0

"

WOMEN

10-03-2017

Sign Type Design

Restroom Identity No Door R_8

60

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

GENERAL NOTES: 1. WALL MOUNTED IDENTIFICATION SIGNAGE. 2. SIGN PANEL TO BE 1/8” THICK PHOTOPOLYMER. PAINT TO MATCH COLOR

INDICATED. 3. SIGN TO BE MOUNTED TO WALL WITH VHB TAPE AND SILICONE ADHESIVE AS

REQUIRED. 4. COORDINATE WITH LAWA FOR SPECIFIC LOCATIONS AND MESSAGES PER

SIGN LOCATION.

ACCESSIBLE

PHONES

ELEVATORS

PET AREA

NURSING ROOM

DRINKING FOUNTAIN

ATM

FRONT ELEVATION1 NOT TO SCALE

SIDE VIEW2 NOT TO SCALE

2

2

ADDITIONAL LAYOUTS4 NOT TO SCALE

10-03-2017

Sign Type Design

General Services Identity WallR_9

61

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

GENERAL NOTES: 1. WALL MOUNTED IDENTIFICATION SIGNAGE. 2. SIGN PANEL TO BE 1/8” THICK PHOTOPOLYMER. PAINT TO MATCH COLOR

INDICATED. 3. SIGN TO BE MOUNTED TO DOOR WITH VHB TAPE AND SILICONE ADHESIVE

AS REQUIRED.

4. COORDINATE WITH LAWA FOR SPECIFIC LOCATIONS.

FRONT ELEVATION1 NOT TO SCALESIDE ELEVATION2 NOT TO SCALE

2

3

CONTEXT ELEVATION3 NOT TO SCALE

3”

9”

3”

9”

MOUNT WITH SILICONE ADHESIVEAND DLUBLE-SIDED TAPE

5’-0

” M

IN

C L

FINISHED FLOOR

SIGN PANEL

STALL DOOR

10-03-2017

Sign Type Design

Wheelchair Accessible Stalls R_10

62

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

GENERAL NOTES: 1 DOUBLE-FACED, NON-ILLUMINATED, CEILING MOUNTED SIGN CABINET. 2. FABRICATED SIGN CABINET WITH INTERNAL FRAMING AS REQUIRED. 3. SIGN PANEL TO BE 3/4” DEEP FABRICATED ALUMINUM WITH PAINT FINISH AS

NOTED. 4. COPY AND GRAPHICS TO BE VINYL DIE CUT IN COLORS INDICATED ON

DRAWING. 5. PRIOR TO BID SUBMISSION, FIELD VERIFY EXISTING CONDITIONS PRIOR TO

FABRICATION OF SIGN. DETERMINE BEST METHOD FOR SIGNAGE INSTALLA-TION. PROVIDE STRUCTURAL ENGINEERING CALCULATIONS.

6. COORDINATE WITH GENERAL CONTRACTOR TO PROVIDE ADDITIONAL SIGNAGE SUPPORT AS REQUIRED.

7. VERTICAL SUPPORTS WITH DECORATIVE CLADDING AS REQUIRED. PROVIDE

SMALLEST DIAMETER AS ALLOWED BY STRUCTURAL ENGINEERING CALCULATIONS.

8. SIGNAGE SHOWN IS FOR PLACEMENT PURPOSES ONLY. FINAL MESSAGE AND

LOCATION OF SIGN TO BE PROVIDED BY LAWA.

9. THE SCALE OF THE SIGNAGE AND GRAPHICS ARE SUBJECT TO CHANGE IN ORDER TO BE COMPLIANT WITH ADA GUIDELINES IF THE INSTALLATION SITE EXCEEDS THE HEIGHT SHOWN IN THE DRAWING PROVIDED.

END VIEW2 NOT TO SCALEFRONT ELEVATION1 NOT TO SCALE

PICTOGRAM FIELD 4

ESCUCHEON PLATE

PICTOGRAM 4 93"

3/4"

1'-6" 1'-4"

4'-0"

4"7"

4 1/2"

5

7

2

3

4

6

Cashier

6'-8

" MIN

.

Sign Type Design

CBP Identity SignW_1

63

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Sign Type Design

Pedestrian Directional – Smaller Overhead W_2

TOP VIEW1 NOT TO SCALE

GENERAL NOTES: 1. DOUBLE-FACED, NON-ILLUMINATED, CEILING MOUNTED SIGN CABINET. 2. FABRICATED SIGN CABINET WITH INTERNAL FRAMING AS REQUIRED. 3. SIGN PANEL TO BE 3/4” DEEP FABRICATED ALUMINUM WITH PAINT FINISH AS

NOTED. 4. COPY AND GRAPHICS TO BE VINYL DIE CUT IN COLORS INDICATED ON

DRAWING. 5. PRIOR TO BID SUBMISSION, FIELD VERIFY EXISTING CONDITIONS PRIOR TO

FABRICATION OF SIGN. DETERMINE BEST METHOD FOR SIGNAGE INSTALLATION WITH CONCEALED MECHANICAL FASTERNERS. PROVIDE STRUCTURAL ENGINEERING CALCULATIONS.

NOTE: THE SCALE OF THE SIGNAGE AND GRAPHICS ARE SUBJECT TO CHANGE IN

ORDER TO BE COMPLIANT WITH ADA GUIDELINES IF THE INSTALLATION SITE EXCEEDS THE HEIGHT SHOWN IN THE DRAWING PROVIDED.

3"

3/4"

6'-8

" MIN

.

FRONT ELEVATION1 NOT TO SCALE SIDE ELEVATION2 NOT TO SCALE

3"3/4"3/4"7

3" TYP.

4 1/4"

4 1/4"

7/8"

7/8"

1"

3/4"

3/4"

5/8"

5/8"

1'-6"

6'

Gates 130-144Bag ClaimRestrooms

64

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

GENERAL NOTES: 1. DOUBLE-FACED, NON-ILLUMINATED, CEILING MOUNTED SIGN CABINET. 2. FABRICATED SIGN CABINET WITH INTERNAL FRAMING AS REQUIRED. 3. SIGN PANEL TO BE 3/4” DEEP FABRICATED ALUMINUM WITH PAINT FINISH AS

NOTED. 4. COPY AND GRAPHICS TO BE VINYL DIE CUT IN COLORS INDICATED ON

DRAWING. 5. DESIGNER TO FIELD VERIFY AND DETERMINE BEST METHOD OF INSTALLATION

WITH MINIMAL VISUAL IMPACT. DESIGNER TO PROVIDE STRUCTURAL ENGINEERING CALCULATIONS AS REQUIRED AND COORDINATE WITH GENERAL CONTRACTOR FOR STRUCTURAL REQUIREMENTS.

6. FIELD VERIFY EXISTING CONDITIONS PRIOR TO BID SUBMISSION. 7. VERTICAL SUPPORTS WITH DECORATIVE CLADDING AS REQUIRED. PROVIDE

SMALLEST DIAMETER AS ALLOWED BY STRUCTURAL ENGINEERING CALCULA-TIONS.

8. SIGNAGE SHOWN IS FOR PLACEMENT PURPOSES ONLY. FINAL MESSAGE AND

LOCATION OF SIGN TO BE PROVIDED BY LAWA.

NOTE: THE SCALE OF THE SIGNAGE AND GRAPHICS ARE SUBJECT TO CHANGE IN

ORDER TO BE COMPLIANT WITH ADA GUIDELINES IF THE INSTALLATION SITE EXCEEDS THE HEIGHT SHOWN IN THE DRAWING PROVIDED.

PLAN VIEW3 NOT TO SCALE

FRONT ELEVATION1 NOT TO SCALEEND VIEW2 NOT TO SCALE

VE

RIF

Y C

LEA

RA

NC

E IN

FIE

LD

FINISHED FLOOR

6'-8

" MIN

.

4”

7

3/4”

3/4”

4TYPICAL INLAYED SYMBOL 4SYMBOL BACKGROUND 4

1" 11 1/2"4"

1'6"

15'-8"

10" 6"

5"

4"4"4" 5"

5 3/4"

2 1/2"

2 5/8"

3"4"

4"

Gates 130-144 RestroomsRestaurants

Sign Type Design

Pedestrian Directional – OverheadW_3

65

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Sign Type Design

CBP Directional Static/Dynamic Overhead W_4GENERAL NOTES: 1. DOUBLE-FACED, NON-ILLUMINATED, CEILING MOUNTED SIGN CABINET WITH

LED DISPLAYS. 2. FABRICATED SIGN CABINET WITH INTERNAL FRAMING AS REQUIRED. 3. SIGN PANEL TO BE 3/4” DEEP FABRICATED ALUMINUM WITH PAINT FINISH AS

NOTED. 4. COPY AND GRAPHICS TO BE VINYL DIE CUT IN COLORS INDICATED ON

DRAWING. 5. LED DISPLAY TO BE PROVIDED BY LAWA. PROVIDE MANUFACTURER’S

REQUIREMENTS FOR VENTILATION IN SIGN CABINET. ALLOW FOR EASE OF MAINTENANCE WITH INCONSPICUOUS ACCESS PANELS.

6. DESIGNER TO FIELD VERIFY AND DETERMINE BEST METHOD OF INSTALLA-

TION WITH MINIMAL VISUAL IMPACT. DESIGNER TO PROVIDE STRUCTURAL ENGINEERING CALCULATIONS AS REQUIRED AND COORDINATE WITH GENERAL CONTRACTOR FOR STRUCTURAL REQUIREMENTS.

7. FIELD VERIFY EXISTING CONDITIONS PRIOR TO BID SUBMISSION.

8. VERTICAL SUPPORTS AND BRACKET WITH DECORATIVE CLADDING AS REQUIRED. PROVIDE SMALLEST DIAMETER AS ALLOWED BY STRUCTURAL ENGINEERING CALCULATIONS.

9. SIGNAGE SHOWN IS FOR PLACEMENT PURPOSES ONLY. FINAL MESSAGE AND

LOCATION OF SIGN TO BE PROVIDED BY LAWA.

NOTE: THE SCALE OF THE SIGNAGE AND GRAPHICS ARE SUBJECT TO CHANGE IN

ORDER TO BE COMPLIANT WITH ADA GUIDELINES IF THE INSTALLATION SITE EXCEEDS THE HEIGHT SHOWN IN THE DRAWING PROVIDED.

PLAN VIEW3 NOT TO SCALE

FRONT ELEVATION (SIDE A)1 NOT TO SCALEEND ELEVATION2 NOT TO SCALE

LED DISPLAY 5

COPY AND GRAPHICS 4 6"3/4"

PICTOGRAM FIELD 4

12'-0"

1'-4

"

1'-6

"

4"

4"

2 1/4"

2 1/4"

3 1/2"

1 5/8"

2 3/8"

5"

5 1/2"

CEILING 7

ARROW 4

8

ESCUCHEON PLATE

Bag Claim 4-8Oversize Bag Claim

Federal Inspection ServicesGround Transport

VE

RIF

Y C

LEA

RA

NC

E IN

FIE

LD

FINISHED FLOOR

6'-8

" MIN

.

66

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

ELEVATION1 NOT TO SCALE

PLAN VIEW3 NOT TO SCALE

END VIEW2 NOT TO SCALE

SIGN CABINET 2

SIGN FACE 3

LED DISPLAY 5

SUPPORTS 7

11'-0"

10'-10"

6"

1"

2'-0"3"

7"

1"

1"

7"

2"3"

GENERAL NOTES: 1. SINGLE-FACED, NON-ILLUMINATED, CEILING MOUNTED SIGN CABINET WITH

LED DISPLAYS. 2. FABRICATED SIGN CABINET WITH INTERNAL FRAMING AS REQUIRED. 3. SIGN PANEL TO BE 3/4” DEEP FABRICATED ALUMINUM. FACE AND RETURNS

TO BE PAINTED IN COLOR AS NOTED. 4. COPY AND GRAPHICS TO BE VINYL DIE CUT IN COLORS INDICATED ON

DRAWING. 5. LED DISPLAY SPECIFICATIONS TO BE APPROVED BY LAWA. PROVIDE

MANUFACTURER’S REQUIREMENTS FOR VENTILATION IN SIGN CABINET. ALLOW FOR EASE OF MAINTENANCE WITH INCONSPICUOUS ACCESS PANELS.

6. DESIGNER TO FIELD VERIFY AND DETERMINE BEST METHOD OF INSTALLA-TION WITH MINIMAL VISUAL IMPACT. DESIGNER TO PROVIDE STRUCTURAL ENGINEERING CALCULATIONS AS REQUIRED AND COORDINATE WITH GENERAL CONTRACTOR FOR STRUCTURAL REQUIREMENTS.

7. VERTICAL SUPPORTS AND BRACKET WITH DECORATIVE CLADDING AS

REQUIRED. PROVIDE SMALLEST DIAMETER AS ALLOWED BY STRUCTURAL ENGINEERING CALCULATIONS.

8. SIGNAGE SHOWN IS FOR PLACEMENT PURPOSES ONLY. FINAL MESSAGE AND

LOCATION OF SIGN TO BE PROVIDED BY LAWA.

NOTE: THE SCALE OF THE SIGNAGE AND GRAPHICS ARE SUBJECT TO CHANGE IN

ORDER TO BE COMPLIANT WITH ADA GUIDELINES IF THE INSTALLATION SITE EXCEEDS THE HEIGHT SHOWN IN THE DRAWING PROVIDED.

Customer Service Representative

VE

RIF

Y C

LEA

RA

NC

E IN

FIE

LD

FINISHED FLOOR

6'-8

" MIN

.

Sign Type Design

CSR Static Dynamic OverheadW_5

67

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Sign Type Design

Wall Identity W_6

GENERAL NOTES: 1. NON-ILLUMINATED, WALL MOUNTED FABRICATED ALUMINUM SIGN CABINET. 2. ALUMINUM SIGN CABINET TO BE FABRICATED IN A MANNER TO ALLOW EASE

OF MAINTENANCE. PROVIDE INTERNAL SUPPORT AS REQUIRED. 3. SIGN FACE TO BE PAINTED ALUMINUM ATTACHED TO SIGN CABINET WITH

BLIND FASTENERS. 4. COPY AND GRAPHICS TO BE VINYL DIE-CUT IN COLOR INDICATED ON

DRAWING. 5. VERIFY EXISTING CONDITIONS PRIOR TO FABRICATION OF SIGN. COORDINATE

WITH GENERAL CONTRACTOR TO PROVIDE ADDITIONAL BLOCKING AS REQUIRED. CONNECTION DETAILS AND STRUCTURAL CALCULATIONS TO BE VERIFIED BY STRUCTURAL ENGINEERING CALCULATIONS.

6. VERIFY FINAL MESSAGE AND LOCATION OF SIGN WITH LAWA. NOTE: THE SCALE OF THE SIGNAGE AND GRAPHICS ARE SUBJECT TO CHANGE IN

ORDER TO BE COMPLIANT WITH ADA GUIDELINES IF THE INSTALLATION SITE EXCEEDS THE HEIGHT SHOWN IN THE DRAWING PROVIDED.

FRONT ELEVATION1 NOT TO SCALESECTION DETAIL2 NOT TO SCALE

1 1/2"

1/4"

SIGN CABINET 2

1'-6"

5'-10"

7" 4"

5 1/2"

1 1/2"

FINISHED FLOOR

VE

RIF

Y C

LEA

RA

NC

E IN

FIE

LD

6'-8

" MIN

.

68

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

GENERAL NOTES: 1. DOUBLE-FACED, NON-ILLUMINATED, CEILING MOUNTED SIGN CABINET. 2. FABRICATED SIGN CABINET WITH INTERNAL FRAMING AS REQUIRED. 3. SIGN PANEL TO BE 3/4” DEEP FABRICATED ALUMINUM WITH PAINT FINISH AS

NOTED. 4. COPY AND GRAPHICS TO BE VINYL DIE CUT IN COLORS INDICATED ON

DRAWING. 5. COORDINATE WITH GENERAL CONTRACTOR TO PROVIDE ADDITIONAL

SIGNAGE SUPPORT AS REQUIRED. 6. DESIGNER TO FIELD VERIFY AND DETERMINE BEST METHOD OF INSTALLA-

TION WITH MINIMAL VISUAL IMPACT. DESIGNER TO PROVIDE STRUCTURAL ENGINEERING CALCULATIONS AS REQUIRED AND COORDINATE WITH GENERAL CONTRACTOR FOR STRUCTURAL REQUIREMENTS.

7. VERTICAL SUPPORTS WITH DECORATIVE CLADDING AS REQUIRED. PROVIDE

SMALLEST DIAMETER AS ALLOWED BY STRUCTURAL ENGINEERING CALCULA-TIONS.

8. SIGNAGE SHOWN IS FOR PLACEMENT PURPOSES ONLY. FINAL MESSAGE AND

LOCATION OF SIGN TO BE PROVIDED BY LAWA.

NOTE: THE SCALE OF THE SIGNAGE AND GRAPHICS ARE SUBJECT TO CHANGE IN

ORDER TO BE COMPLIANT WITH ADA GUIDELINES IF THE INSTALLATION SITE EXCEEDS THE HEIGHT SHOWN IN THE DRAWING PROVIDED.

FRONT ELEVATION1 NOT TO SCALESIDE ELEVATION2 NOT TO SCALE

9

5 6 74"

4"

1"

1"

1 1/8"

1 1/8"

1 3/8"

1 3/8"

3"1'-6"

3"3/4"3/4"

Information Upper BoardingRestrooms

EXIT and Connecting FlightsGround Transport

Elevators

6'-8

" MIN

.

Sign Type Design

Pedestrian Directional – Small OverheadW_7

69

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Sign Type Design

Small Directional – Wall W_8

Exit

Bag ClaimRestrooms

GENERAL NOTES: 1. SINGLE-FACED, NON-ILLUMINATED, WALL MOUNTED SIGN CABINET. 2. FABRICATED SIGN CABINET WITH INTERNAL FRAMING AS REQUIRED. 3. SIGN PANEL TO BE 3/4” DEEP FABRICATED ALUMINUM WITH PAINT FINISH AS

NOTED. 4. COPY AND GRAPHICS TO BE VINYL DIE CUT IN COLORS INDICATED ON

DRAWING. 5. DESIGNER TO FIELD VERIFY AND DETERMINE BEST METHOD OF INSTALLA-

TION WITH MINIMAL VISUAL IMPACT. DESIGNER TO PROVIDE STRUCTURAL ENGINEERING CALCULATIONS AS REQUIRED AND COORDINATE WITH GENERAL CONTRACTOR FOR STRUCTURAL REQUIREMENTS.

6. FIELD VERIFY EXISTING CONDITIONS PRIOR TO FABRICATION OF SIGN. 7. SIGNAGE SHOWN IS FOR PLACEMENT PURPOSES ONLY. FINAL MESSAGE AND

LOCATION OF SIGN TO BE PROVIDED BY LAWA.

NOTE: THE SCALE OF THE SIGNAGE AND GRAPHICS ARE SUBJECT TO CHANGE IN

ORDER TO BE COMPLIANT WITH ADA GUIDELINES IF THE INSTALLATION SITE EXCEEDS THE HEIGHT SHOWN IN THE DRAWING PROVIDED.

TYPICAL INLAYED SYMBOL 4SYMBOL BACKGROUND 4

8

5.

5

4"

4"

1 1/8"

1 1/8"

1"

1"

1 3/8"

1 3/8"3"1'-6"

6'-0"

FRONT ELEVATION1 NOT TO SCALE

PARTIAL SECTION DETAIL3 NOT TO SCALE

SIDE ELEVATION2 NOT TO SCALE

FINISHED FLOOR

6'-8

" MIN

.

VE

RIF

Y C

LEA

RA

NC

E IN

FIE

LD

70

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

GENERAL NOTES: 1. WALL MOUNTED PLAQUE WITH PAINTED BACKGROUND AND SCREENED

GRAPHICS. 2. SIGN PANEL TO BE 1/8” THICK BRUSHED ALUMINUM WITH MASKED AND

PAINTED BACKGROUND. 3. COPY TO BE VINYL DIE-CUT WITH COLOR TO MATCH AS INDICATED ON

DRAWING. 4. FLUSH MOUNT ONTO EXISTING INTERIOR WALL WITH SILICONE ADHESIVE AND

VHB TAPE AS REQUIRED. 5. LAWA TO PROVIDE SPECIFIC MESSAGE PER LOCATION OF SIGN.

NOTE: THE SCALE OF THE SIGNAGE AND GRAPHICS ARE SUBJECT TO CHANGE IN

ORDER TO BE COMPLIANT WITH ADA GUIDELINES IF THE INSTALLATION SITE EXCEEDS THE HEIGHT SHOWN IN THE DRAWING PROVIDED.

FRONT ELEVATION1 NOT TO SCALE

BACKGROUND FIELD10" 2"3"

2 1/2"

2 1/2"

1"

1"

1/2"

1/2"

5'-0"

Rooms 00-00 Rooms 00-00

FINISHED FLOOR

BASELINE OF CHARACTERS

6'-8

" Max

.

VE

RIF

Y C

LEA

RA

NC

E IN

FIE

LD

Sign Type Design

Wayfinding Directional – WallW_9

71

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Sign Type Design

Pedestrian Direction – Wall W_10

GENERAL NOTES: 1. NON-ILLUMINATED, WALL MOUNTED FABRICATED ALUMINUM SIGN CABINET. 2. ALUMINUM SIGN CABINET TO BE FABRICATED IN A MANNER TO ALLOW EASE

OF MAINTENANCE. PROVIDE INTERNAL SUPPORT AS REQUIRED. 3. SIGN FACE TO BE PAINTED ALUMINUM ATTACHED TO SIGN CABINET WITH

BLIND FASTENERS. 4. COPY AND GRAPHICS TO BE VINYL DIE-CUT IN COLOR INDICATED ON

DRAWING. 5. VERIFY EXISTING CONDITIONS PRIOR TO FABRICATION OF SIGN. COORDINATE

WITH GENERAL CONTRACTOR TO PROVIDE ADDITIONAL BLOCKING AS REQUIRED. CONNECTION DETAILS AND STRUCTURAL CALCULATIONS TO BE VERIFIED BY STRUCTURAL ENGINEERING CALCULATIONS.

6. VERIFY FINAL MESSAGE AND LOCATION OF SIGN WITH LAWA.

NOTE: THE SCALE OF THE SIGNAGE AND GRAPHICS ARE SUBJECT TO CHANGE IN

ORDER TO BE COMPLIANT WITH ADA GUIDELINES IF THE INSTALLATION SITE EXCEEDS THE HEIGHT SHOWN IN THE DRAWING PROVIDED.

6"4"

4"

2 3/4"

2 5/8"

2 5/8"

VARIES

FRONT ELEVATION1 NOT TO SCALE

1'-6" 7"

4 1/2"

1 1/2"

1 1/2"

4 1/2"

4"

1"

1"

SECTION DETAIL2 NOT TO SCALE

1 1/2"

1/4"

SIGN CABINET 2

FINISHED FLOOR

6'-8

" MIN

.

VE

RIF

Y C

LEA

RA

NC

E IN

FIE

LD

RestroomsGates 130-144

Restaurants

72

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Sign Type Design

Informational Sign PlacardW_11

GENERAL NOTES: 1. WALL MOUNTED PLAQUE WITH PAINTED BACKGROUND OR SCREENED

GRAPHICS. 2. SIGN PANEL TO BE 1/8” THICK PHOTOPOLYMER COLOR TO MATCH THE

SCREEN PRINTED GRAPHICS. 3. FLUSH MOUNT ONTO EXISTING INTERIOR WALL WITH SILICONE ADHESIVE AND

VHB TAPE AS REQUIRED. 4. TYPESTYLE: HELVETICA NEUE LT PRO 65 MEDIUM. 5. LAWA TO PROVIDE SPECIFIC MESSAGE PER LOCATION OF SIGN.

FRONT ELEVATION1 NOT TO SCALE

1'-6"

2'-6"

1"3/4"

1"3/4"

1"3/4"

1"3/4"

1"3/4"

1"3/4"

1"3/4"

1"3/4"

1"

1 1/2"

1 1/2"

In the course of normal handling, yourluggage may acquire evidence of use,such as minor cuts, scratches, dentsor soil.We trust you to understand that weare not responsible for conditions thatresult from this type of normal wearand tear.Thank You.

73

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Sign Type Design

Directional Sign Placard W_12

GENERAL NOTES: 1. WALL MOUNTED PLAQUE WITH PAINTED BACKGROUND OR SCREENED

GRAPHICS. 2. SIGN PANEL TO BE 1/8” THICK PHOTOPOLYMER COLOR TO MATCH THE

SCREEN PRINTED GRAPHICS. 3. FLUSH MOUNT ONTO EXISTING INTERIOR WALL WITH SILICONE ADHESIVE AND

VHB TAPE AS REQUIRED. 4. TYPESTYLE: HELVETICA NEUE LT PRO 65 MEDIUM. 5. LAWA TO PROVIDE SPECIFIC MESSAGE PER LOCATION OF SIGN.

NOTE: VARIANCES

FRONT ELEVATION1 NOT TO SCALE

1'-6"

2"

2"

1"1 3/4"

1 3/4"

3/4"

6 1/2"

1 1/8"

1 1/8"

2'-6"

Gates 30-39Located in Terminal 3

(Alternate text or foreign language)

74

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

GENERAL NOTES: 1. DOUBLE-FACED, NON ILLUMINATED, FREESTANDING PYLON SIGN WITH

REPLACEABLE MAP DIRECTORY. 2. FABRICATED ALUMINUM CABINET WITH INTERNAL STRUCTURE AS REQUIRED. 3. SIGN PANELS TO BE FABRICATED ALUMINUM PAINTED IN COLOR INDICATED.

ATTACH TO SIGN CABINET IN AN INCONSPICUOUS MANNER. 4. COPY AND GRAPHICS TO BE VINYL DIE-CUT TO MATCH COLORS INDICATED ON

DRAWING. 5. LED DISPLAY SPECIFICATIONS TO BE APPROVED BY LAWA. PROVIDE

MANUFACTURER’S REQUIREMENTS FOR VENTILATION IN SIGN CABINET. ALLOW FOR EASE OF MAINTENANCE WITH INCONSPICUOUS ACCESS PANELS.

6. DESIGNER TO FIELD VERIFY EXISTING CONDITIONS AND COORDINATE WITH

GENERAL CONTRACTOR FOR BEST METHOD OF INSTALLATION. DESIGNER TO PROVIDE STRUCTURAL AND FOOTING REQUIREMENTS BASED ON STRUCTUR-AL ENGINEERING CALCULATIONS.

7. LAYOUT SHOWN IS FOR PLACEMENT PURPOSES ONLY. LAWA TO PROVIDE

SPECIFIC MESSAGES PER SIGN LOCATION.

SIGN CABINET 2

SIGN PANEL 3

BASE COVER

FOOTING 7

DIRECTORY/MAP 5

COPY AND GRAPHICS 4

7'-4"8'-0"

8"

4'-0"

2" 1" 1"2 1/

8"

2 1/

2"

2"1 3/8"

2"1 3/8"

2"1 3/8"

2"1 3/8"

2"1 3/8"

2"

3 5/8"

1"2 1/2"

2'-8"

2'-5"

4"

1" 1"

Gates 130-148N. ConcourseAirline LoungesShoppingRestroomsConcessions

W. 98th St.

Sky W

ay 96th St. Bridge

P-2A

P-6VP-6VP

-4

P-2P-1

P-7

P-3

P-5P-4

Departure

East

Way

East

Way

Way

Departure

Arrival

Upper Level

Lower Level

Arrival

Upper Level

Lower Level

Lowe

r

Lev

el

Uppe

r

Lev

el

Tom

Bra

dley

Inte

rnat

iona

l Ter

min

al

Long-TermPublic Parking

Lot CFree Bus Service to

Airline Terminals

Long-TermPublic Parking

Lot B

Lincoln Blvd.

Arbor Vitae St.

W. 96th St.

Airp

ort

.dvlB

Century Blvd.

From I-405 Fwy.

104th St.

111th St.

Imperial Hwy

Free Bus Service toAirline Terminals

La C

iene

ga

.dvlB

Wes t

evlupeSda

Blv

d.

Wes

t

Center Way

Uppe

r Lev

el

Lowe

r Lev

el

Wes

t Way

1

1

123

4 5 6 7 8405

405

105

NORTH

Metro Rail Green LineImperial Hwy. & Aviation Blvd.

Lot B111th & La Cienega Blvd.

Cell Phone Waiting LotAirport Blvd. & Arbor Vitae St.

FRONT ELEVATION1 NOT TO SCALESIDE ELEVATION2 NOT TO SCALE

Sign Type Design

Small Freestanding DirectionalW_13

75

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Sign Type Design

Freestanding Directory W_14

GENERAL NOTES: 1. DOUBLE-FACED, NON ILLUMINATED, FREESTANDING PYLON SIGN WITH VINYL

COPY. 2. FABRICATED ALUMINUM CABINET WITH INTERNAL STRUCTURE AS REQUIRED. 3. SIGN PANELS TO BE FABRICATED ALUMINUM PAINTED IN COLOR INDICATED.

ATTACH TO SIGN CABINET IN AN INCONSPICUOUS MANNER. 4. COPY AND GRAPHICS TO BE VINY DIE-CUT APPLIED TO SIGN PANEL. 5. FIELD VERIFY EXISTING CONDITIONS. COORDINATE WITH GENERAL CONTRAC-

TOR FOR BEST METHOD OF INSTALLATION. PROVIDE STRUCTURAL AND FOOTING REQUIREMENTS BASED ON STRUCTURAL ENGINEERING CALCULA-TIONS.

6. DESIGNER TO FIELD VERIFY AND DETERMINE BEST METHOD OF INSTALLATION

WITH MINIMAL VISUAL IMPACT. DESIGNER TO PROVIDE STRUCTURAL ENGINEERING CALCULATIONS AS REQUIRED AND COORDINATE WITH GENERAL CONTRACTOR FOR STRUCTURAL REQUIREMENTS.

7. FABRICATED BASE COVER TO BE FABRICATED IN A MANNER TO WITHSTAND

ABUSE FROM LUGGAGE CARTS. 8. MESSAGES SHOWN ARE FOR PLACEMENT PURPOSES ONLY. LAWA TO

PROVIDE SPECIFIC MESSAGES PER SIGNAGE LOCATION.

8'-0"

1/2"

40"

MIN

.

1/2"

5'-10"

2'-6"

5 1/8"

1 1/8"1 1/8"2 7/16"

8"

3 3/8"

3 3/8"

1 3/4"

4 1/8"

4 1/8"

4 1/8"

3 3/8"

4 1/8"

3 3/8"

4 1/8"

4 1/8"

6 3/4"

6 3/4"

2" TYP

1"

FRONT ELEVATION1 NOT TO SCALE

SIDE ELEVATION2 NOT TO SCALE

SIGN CABINET 2

6

BASE 7

FINISHED FLOOR

Gates

Escalator

Lounge

Elevator

Shopping

Restrooms

Food

76

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

GENERAL NOTES: 1. DOUBLE-FACED, NON ILLUMINATED, FREESTANDING PYLON SIGN WITH

MONITOR, POSTER CABINET AND VINYL COPY. 2. FABRICATED ALUMINUM CABINET WITH INTERNAL STRUCTURE AS REQUIRED. 3. SIGN PANELS TO BE FABRICATED ALUMINUM PAINTED IN COLOR INDICATED.

ATTACH TO SIGN CABINET IN AN INCONSPICUOUS MANNER. 4. COPY AND GRAPHICS TO BE VINY DIE-CUT APPLIED TO SIGN PANEL. 5. FIELD VERIFY EXISTING CONDITIONS. COORDINATE WITH GENERAL

CONTRACTOR FOR BEST METHOD OF INSTALLATION. PROVIDE STRUCTURAL AND FOOTING REQUIREMENTS BASED ON STRUCTURAL ENGINEERING CALCULATIONS.

6. LED DISPLAY SPECIFICATIONS TO BE APPROVED BY LAWA. PROVIDE

MANUFACTURER’S REQUIREMENTS FOR VENTILATION IN SIGN CABINET. ALLOW FOR EASE OF MAINTENANCE WITH INCONSPICUOUS ACCESS PANELS.

7. POSTER RETAINER TO BE TEMPERED GLASS WITH FABRICATED FRAME TO

MATCH SIGN PANEL. PROVIDE CONTINUOUS HINGE AND TWO LOCKS KEYED ALIKE. PROVIDE TOOL-LESS FASTENERS AND BACKER PANEL TO RETAIN POSTER.

8. MONITOR TO BE PROVIDED BY LAWA. INSTALL IN A MANNER TO ALLOW EASE

OF MAINTENANCE. FOLLOW MANUFACTURERS RECCOMENDATIONS FOR INSTALLATION INCLUDING VENTILATION REQUIREMENTS.

9. DESIGNER TO FIELD VERIFY AND DETERMINE BEST METHOD OF INSTALLA-

TION WITH MINIMAL VISUAL IMPACT. DESIGNER TO PROVIDE STRUCTURAL ENGINEERING CALCULATIONS AS REQUIRED AND COORDINATE WITH GENERAL CONTRACTOR FOR STRUCTURAL REQUIREMENTS.

10. ESTIMATED SIGN WATTAGE REQUIREMENTS: 2500W ESTIMATED SIGN WEIGHT: 1200 LBS. 11. MESSAGES SHOWN ARE FOR PLACEMENT PURPOSES ONLY. LAWA TO

PROVIDE SPECIFIC MESSAGES PER SIGNAGE LOCATION.

OPTION 1

14'-0"

2'-3"

2'-1"

3 1/8"

3 1/2"

3 1/2"

3 1/2"

1 1/4"

3 7/8"

3 7/8"3 1/2"1 1/4"

3 1/2"

3 1/2"

1'-2 1/2"

1 1/4"

1 3/4"2"

1 3/4"2"

1 3/4"2"2"

5 1/2"

1 3/4"

1'-10 3/8"

2"2"

3"

1"

1'-4"

1'-2"

9

SIGN PANEL 3

TYP. COPYAND GRAPHICS 4

SIGN CABINET 2

SUGGESTED SEAMLOCATION

CONTINUOUS HINGE

TYP. LOCKS 7

SUGGESTED SEAMLOCATION

MONITOR 8

MONITOROPENING 8

SIGN PANEL 3

TYP. COPYAND GRAPHICS 5

SIGN CABINET 2

ELEVATION (SIDE A)1 NOT TO SCALE

PLAN VIEW3 NOT TO SCALE

END ELEVATION 2 NOT TO SCALEELEVATION (SIDE B) 4 NOT TO SCALE

5'-10"MAX.

Gates150-159

Gates130-146

LoungeEscalatorsElevatorsRestrooms

RestaurantsDuty Free

Sign Type Design

Large Freestanding DirectionalW_15

77

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

Sign Type Design

Freestanding Directory W_16GENERAL NOTES: 1. DOUBLE-FACED, NON ILLUMINATED, FREESTANDING PYLON SIGN WITH

MONITOR, POSTER CABINET AND VINYL COPY. 2. FABRICATED ALUMINUM CABINET WITH INTERNAL STRUCTURE AS REQUIRED. 3. SIGN PANELS TO BE FABRICATED ALUMINUM PAINTED IN COLOR INDICATED.

ATTACH TO SIGN CABINET IN AN INCONSPICUOUS MANNER. 4. COPY AND GRAPHICS TO BE VINY DIE-CUT APPLIED TO SIGN PANEL. 5. POSTER RETAINER TO BE TEMPERED GLASS WITH FABRICATED FRAME TO

MATCH SIGN PANEL. PROVIDE CONTINUOUS HINGE AND TWO LOCKS KEYED ALIKE. PROVIDE TOOL-LESS FASTENERS AND BACKER PANEL TO RETAIN POSTER.

6. LED DISPLAY SPECIFICATIONS TO BE APPROVED BY LAWA. PROVIDE

MANUFACTURER’S REQUIREMENTS FOR VENTILATION IN SIGN CABINET. ALLOW FOR EASE OF MAINTENANCE WITH INCONSPICUOUS ACCESS PANELS.

7. DESIGNER TO FIELD VERIFY AND DETERMINE BEST METHOD OF INSTALLA-

TION WITH MINIMAL VISUAL IMPACT. DESIGNER TO PROVIDE STRUCTURAL ENGINEERING CALCULATIONS AS REQUIRED AND COORDINATE WITH GENERAL CONTRACTOR FOR STRUCTURAL REQUIREMENTS.

8. ESTIMATED SIGN WATTAGE REQUIREMENTS: 2500W ESTIMATED SIGN WEIGHT: 1200 LBS. 9. MESSAGES SHOWN ARE FOR PLACEMENT PURPOSES ONLY. LAWA TO

PROVIDE SPECIFIC MESSAGES PER SIGNAGE LOCATION.

ELEVATION (SIDE A)1 NOT TO SCALEEND ELEVATION 2 NOT TO SCALE

ELEVATION (SIDE B) 4 NOT TO SCALE

TOP VIEW 3 NOT TO SCALE

SIGN PANEL 3

TYP. COPYAND GRAPHICS 4

SIGN CABINET 2

SUGGESTED SEAMLOCATION

SUGGESTED SEAMLOCATION

VENT 8

SIGN CABINET 2

FOOTING 9

CONTINUOUS HINGE

TYP. LOCKS 5

MONITOR 6

7

MONITOROPENING 6

SIGN PANEL 3

TYP. COPYAND GRAPHICS 4 9

SIGN CABINET 2

3'-3"

6"

5"

1 1/2"

2 1/4"

5"2 1/4"

6 3/4"

3'-0"

3"2 3/4"

3"2 3/4"

3"2 3/4"

3"8 1/2"

3"2 3/4"

5'-10"MAX.

4'-3 3/4"

20'-0"

2'-5"±

4'-1"±

3"

5"

5"

5"

5"

1'-11"4 1/4"

2 1/4"

6 3/4"

LoungesEscalatorsElevatorsRestrooms

RestaurantsDuty Free

Gates

Gates

150-159

130-146

LoungesEscalatorsElevatorsRestrooms

RestaurantsDuty Free

Gates

Gates

150-159

130-146

Gates148

OPTION 2

78

Los Angeles World AirportsTerminal Wayfinding StandardsSignage Design Guide

10-03-2017

FRONT ELEVATION1 NOT TO SCALESIGN PANEL2 NOT TO SCALE

CONTEXT ELEVATION3 NOT TO SCALE

GENERAL NOTES:

1. PURCHASE AND INSTALL PET STATION AND FABRICATE AND INSTALL TOP SIGN PANEL AS NOTED.

2. PURCHASE PET STATION AS NOTED. PROVIDE FOOTING TO RECEIVE TELESCOPIC POST AS REQUIRED.

3. SIGN PANEL TO BE 1/8” PANEL WITH SCREEN PRINTED GRAPHICS AS NOTED.

4. DESIGNER TO FIELD VERIFY AND DETERMINE BEST METHOD OF INSTALLA-TION WITH MINIMAL VISUAL IMPACT. DESIGNER TO PROVIDE STRUCTURAL ENGINEERING CALCULATIONS AS REQUIRED AND COORDINATE WITH GENERAL CONTRACTOR FOR FOOTING REQUIREMENTS.

PLEASE CLEAN UPAFTER YOUR DOG!

1'-8"1'-10"

2 "

1'-3 3/4"

1'-11"

4'-0"

5'-10"

8 1/2"

1"

11 1/2"

1'-8"

1 1/4"

1"

1"

1"

1 1/2"

3/4"

3/4"

3/4" 1 1/2"

1 1/4"

3/8"

1 5/8"

3 3/8"

2"

2"

2"

1/2"

2” x 2” x 5’10”

PetReliefAreaPlease pick-upafter your pet.No Smoking.

PLEASE CLEAN UPAFTER YOUR DOG!

Sign Type Design