FIBRE OPTIC CABLE
| SYDNEY | MELBOURNE | BRISBANE | PERTH | JCSTECH.COM.AU
LOOSE TUBE
LOOSE TUBE FIBREOPTIC CABLEJCS offers a range of outdoor optical cables for external underground duct installation and direct burial. Cables are available in a range of fibre counts, fibre types and mechanical constructions depending on the specific application.
OPTICAL FIBRE
JCS loose tube cables can be supplied in the full range of optical fibres available to meet the demands of different applications, including multimode OM1, OM3 and singlemode OS1 and OS2 fibres.
2 LOOSE TUBE FIBRE OPTIC CABLE | JCS TECHNOLOGIES | SYDNEY | MELBOURNE | BRISBANE | PERTH | JCSTECH.COM.AU
Multi - loose tube dielectric optical cable designed for external underground duct installation or direct burial. Advanced design with GRP central strength member for greatly reduced cable size, offering fibre counts from 2 to 144 and many benefits for both installers and network owners.
All-dielectric multi-loose tube fibre optic cable for external underground duct installation or direct burial. Advanced design with GRP central strength member for greatly reduced cable size, offering fibre counts from 2 to 144. A protective layer of lightweight, flat GRP non-metallic armour to withstand rodent attack.
Loose tube dielectric optical cable with 6, 12 or 24 fibres, designed for external underground duct installation or direct burial. The cable is designed with glass fibre reinforced plastic peripheral strength members for enhanced fibre protection in installation applications where mechanical impact is expected. LSZH option available.
SM@RTCORE LOOSE TUBE FIBREOPTIC CABLE
ARM@CORE LOOSE TUBE FIBREOPTIC CABLE
SM@RTCORE CENTRAL TUBE FIBREOPTIC CABLE
SM@RTCORE LOOSE-TUBE FIBREOPTIC CABLELoose tube dielectric optical cable designed for external underground installations in ducts by pulling, jetting or floating techniques or by direct burial in open-cut trenches. Low-viscosity gel-filled fibre tubes. Advanced cable design and manufacture has enabled greatly reduced cable size, offering many benefits for both installers and network owners. GRP central strength member, UV stabilised polyethylene sheath.
See the relevant cabled optical fibre data sheet.
• Single layer multi-loose tube construction• Central strength member (CSM)• Thermoplastic Tube with up to 12 fibres filled with a low viscosity, thixotropic, non-melting gel• Tube and filler elements SZ stranded around CSM• Water swellable elements (dry-core) for water tightness• UV stabilised polyethylene sheath• Two ripcords beneath sheath for easy removal• UV stabilised nylon outer jacket bonded to PE sheath
FEATURES • Reduced diameter, smaller cable
cross section, high fibre density
• Multi – loose tube construction, with fibre counts from 2 to 144
• Internal dry water blocking technology
• Composite UV stabilised polyethylene / bonded outer nylon jacket
• Termite resistant
• Low duct hauling friction
APPLICATIONS• External underground duct
installation
• Direct burial
CABLE DESIGN
TECHNICAL DATA
OPTICAL CHARACTERISTICS
Number of Fibres 2-72 84-96 108-120 132-144
No. of elements 6 8 10 12
Tube/filler diameter 2.1 mm
Cable nominal diameter 10.0 10.7 12.2 13.6 mm
Cable nominal weight 75 92 126 153 kg/km
Max installation tension 2.0 2.5 kN
Max crush resistance 2.0 (short term) / 1.0 (long term) kN/100mm
Min bend radius 20 x cable OD (full load) / 10 x cable OD (no load) mm
Temperature range
installation 0 to +50⁰C
⁰Cstorage -20 to +70⁰C
operation -10 to +70⁰C
LOOSE TUBE FIBRE OPTIC CABLE | JCS TECHNOLOGIES | SYDNEY | MELBOURNE | BRISBANE | PERTH | JCSTECH.COM.AU 3
SM@RTCORE LOOSE-TUBE CABLEIDENTIFICATION
MECHANICAL CHARACTERISTICS
Sheath Colour: The outer sheath colour is blue.Sheath Marking: The outer sheath is marked in 1 meter intervals as follows:
Packing: New non-returnable timber drums to AS/NZS 2857 with NOLCO-FLEX protectionDelivery Lengths: Standard delivery length is 4 km with a tolerance of - 1% / + 3%
No. Colour1 2 3 4 5 6 7 8 9 10 11 12
blue orange green brown grey white red black yellow violet pink aqua
Fibre and Buffer Tube Colours
Fillers are either natural (opaque) or black.
Parameter Test Method Test Conditions Acceptance Criteria
Tensile strength IEC 60794-1-2-E1Load per cable max tensile strength
max fibre strain < 0.6%/30mins∆ attenuation < 0.1dB
Crush IEC 60794-1-2-E310/120 min, load per max crush resistance, 3 adjacent sections
No sheath or core damage∆ attenuation < 0.1dB
Impact IEC 60794-1-2-E4Wt: 1.5 kg, Ht: 1.0 mAnvil Ø: 25 mm, Impacts: 1
No fibre, sheath or core damage∆ attenuation < 0.1dB/5 mins
Torsion IEC 60794-1-2-E7Tension: per cable spec. Rotation 10 half-turn cycles ea. clockwise and anti-clockwise / 1m / 1 min.
No fibre breaks, no sheath or core structure damage. ∆ attenuation < 0.1dB
Bend IEC 60794-1-2-E11 Mandrel Ø: 20 x Cable OD, 1 turn ∆ attenuation < 0.1dB
Bend under tension
Concurrent totensile testIEC 60794-1-2-E18
Mandrel Ø: 40 x Cable OD, 1 turnNo fibre, sheath or core damage∆ attenuation < 0.1dB/5 mins
Temperature cycling
IEC 60794-1-2-F1Min. sample length: 1000m–10⁰C to +70⁰C
no avg. attenuation increase /∆T. No fibre attenuation > 0.15dB/km
Water penetration
IEC 60794-1-2-F5B Length = 3m, Water ht. = 1m No water leakage after 24 hrs.
F L S – X X X – X X – X – X X X X
FIBRE TYPE
FIBRE CORESCABLE LENGTH (m)
OVERSHEATHING
002 to 144
O - OversheathingX - None
M1 - OM1M3 - OM3S1 - OS1S2 - OS2
ORDERING INFORMATION
4 LOOSE TUBE FIBRE OPTIC CABLE | JCS TECHNOLOGIES | SYDNEY | MELBOURNE | BRISBANE | PERTH | JCSTECH.COM.AU
ARM@CORE ALL DIELECTRIC RODENT PROOF LOOSETUBE OPTICAL CABLEAll dielectric loosetube fibre optic cable for external underground installations in ducts or direct burial in open-cut trenches, and designed to withstand rodent attack. Low-viscosity gel-filled fibre tubes. Advanced cable design and manufacture has enabled greatly reduced cable size, offering many benefits for both installers and network owners. Glass fibre reinforced plastic non-conductive central strength member and armour rods, UV stabilised Polyethylene / Nylon sheath.
• Single layer multi-loose tube construction
• GRP central strength member (CSM) with/without over-sheath
• Thermoplastic Tube with up to 12 fibres filled with a low viscosity, thixotropic, non-melting gel
• Tubes and fillers are SZ stranded around the CSM
• Water swellable elements (dry-core technology)
• Polyethylene AS1049 compliant bedding
• Flat GRP rod armour
• AS1049 compliant polyethylene sheath with 2 ripcords
• UV resistant AS1049 compliant bonded nylon outer jacket
FEATURES • Reduced diameter, high fibre density
• Multi – loose tube with 2 to 144 fibres
• Rodent proof GRP layer, independently tested
• Internal dry water blocking technology
• Composite UV stabilised polyethylene / bonded outer nylon jacket
• Termite resistant
• Low duct hauling friction
• Non-conductive
APPLICATIONS• External underground duct
installation
• Direct burial
®www.prysmiangroup.com Issued 2014-06-10
Page 1 of 2
F(12-144)_LTNG
FTL4/D2EP1
External Underground Loosetube All Dielectric Rodent Proof Optical Cable
Cable Design
IEC 60794-3-11
ACMA - AS/CA S008
- Drawing not to scale -
Multi-loosetubeconstruction–Single layer2 to144 fibres
Centralstrengthmember(CSM):Glass fibre reinforcedplasticmaterial (GRP)withorwithoutover-sheathing
Tube:Thermoplasticmaterial, containingup to12single-modeoptical fibres filledwitha lowviscosity, thixotropic,non-meltinggel fully compatiblewith fibrecoatingandtubematerial
Stranding:Therequirednumbersofelements (tubesand fillers)areSZstrandedaroundthecentral strengthmember
Longitudinalwatertightness:Waterswellableelements (dry-core technology)
Bedding:Polyethylene incompliancewithAS1049
Armour:FlatGRPRods
Sheath:Polyethylene incompliancewithAS1049.Tworipcordsprovidedbeneaththesheath foreasy removal
Outerjacket:UV resistant polyamide (Nylon) in compliance with AS1049 integrally bonded to PE sheath
Technical data
Number of Fibres 2 to 72 84 - 96 108 - 120 132 - 144
Number of elements 6 8 10 12
Tube / Filler diameter mm 2.1
Cable nominal diameter mm 13.8 14.8 16.6 18.5
Cable nominalweight kg/km 165 189 244 298
Max. installation tension kN 4.0
Max. crush resistance kN/100mm 4.0 (Short term) /2.0 (Long term)
Min. bending radius mmAt full load 30xCableODAtno load 15xCableOD
Temperature range °C Installation -0 ->+50 Transport &Storage -20 -> +70 Operation -10 ->+70
Optical Characteristics
See the attached cabled optical fibre data sheet.
Identification
Fibre and Buffer Tube Colours
No. 1 2 3 4 5 6 7 8 9 10 11 12
Colour blue orange green brown grey white red black yellow violet pink aqua
Fillers are either natural (opaque) or black, jelly filled tubes (with no fibres) are also used.
This loose tube dielectric optical cable is designed for external underground installations in ducts or by direct burial. GRParmour provides rodent protection and polyamide provides anti-termite protection.
See the relevant cabled optical fibre data sheet.
CABLE DESIGN
TECHNICAL DATA
OPTICAL CHARACTERISTICS
Number of Fibres 2-72 84-96 108-120 132-144
No. of elements 6 8 10 12
Tube/filler diameter 2.1 mm
Cable nominal diameter 13.8 14.8 16.6 18.5 mm
Cable nominal weight 165 189 224 298 kg/km
Max installation tension 4.0 kN
Max crush resistance 4.0 (short term) / 2.0 (long term) kN/100mm
Min bend radius 30 x cable OD (full load) / 15 x cable OD (no load) mm
Temperature range
installation 0 to +50⁰C
⁰Cstorage -20 to +70⁰C
operation -10 to +70⁰C
LOOSE TUBE FIBRE OPTIC CABLE | JCS TECHNOLOGIES | SYDNEY | MELBOURNE | BRISBANE | PERTH | JCSTECH.COM.AU 5
ARM@CORE RODENT PROOF LOOSE-TUBE CABLE IDENTIFICATION
Sheath Colour: The outer sheath colour is blue.Sheath Marking: The outer sheath is marked in 1 meter intervals as follows:
Packing: New non-returnable timber drums to AS/NZS 2857 with NOLCO-FLEX protectionDelivery Lengths: Standard delivery length is 4 km with a tolerance of - 1% / + 3%
No. Colour1 2 3 4 5 6 7 8 9 10 11 12
blue orange green brown grey white red black yellow violet pink aqua
Fibre and Buffer Tube Colours
Fillers are either natural (opaque) or black, jelly-filled tubes (no fibres) are also used.
MECHANICAL CHARACTERISTICS
F L A – X X X – X X – X – X X X X
FIBRE TYPE
FIBRE CORESCABLE LENGTH (m)
OVERSHEATHING
002 to 144
O - OversheathingX - None
M1 - OM1M3 - OM3S1 - OS1S2 - OS2
ORDERING INFORMATION
Parameter Test Method Test Conditions Acceptance Criteria
Tensile strength IEC 60794-1-2-E1 Load per cable max tensile strengthmax fibre strain < 0.6%/30mins∆ attenuation < 0.1dB
Crush IEC 60794-1-2-E310/120 min, load per max crush resistance, 3 adjacent sections
No sheath or core damage∆ attenuation < 0.1dB
Impact IEC 60794-1-2-E4Wt: 1.5 kg, Ht: 1.0 mAnvil Ø: 25 mm, Impacts: 1
No fibre, sheath or core damage∆ attenuation < 0.1dB/5 mins
Torsion IEC 60794-1-2-E7Tension: per cable spec. Rotation / 1m: 1 turn clockwise / 1 min. and 2 turns anti-clockwise / 2 mins.
No fibre breaks, no sheath or core structure damage. ∆ attenuation < 0.1dB
Bend IEC 60794-1-2-E11 Mandrel Ø: 180mm, 1 turn ∆ attenuation < 0.1dB
Bend under tension
Concurrent totensile testIEC 60794-1-2-E18
Mandrel Ø: 360mm, 1 turnNo fibre, sheath or core damageΔ attenuation < 0.1dB/5 mins
Temperature cycling
IEC 60794-1-2-F1Min. sample length: 1000m–10⁰C to +70⁰C
no avg. attenuation increase /∆T. No fibre attenuation > 0.15dB/km
Water penetration IEC 60794-1-2-F5B Length = 3m, Water ht. = 1m No water leakage after 24 hrs.
6 LOOSE TUBE FIBRE OPTIC CABLE | JCS TECHNOLOGIES | SYDNEY | MELBOURNE | BRISBANE | PERTH | JCSTECH.COM.AU
See the relevant cabled optical fibre data sheet.
OPTICAL CHARACTERISTICS
TECHNICAL DATA
OPTICAL CHARACTERISTICS
Number of Fibres 6 – 12 – 24
No. of elements 1
Tube/filler diameter 3.7 mm
Cable nominal diameter 8.4 mm
Cable nominal weight 73.5 (LSZH) / 53.5 (PE) kg/km
Max installation tension 2.0 kN
Max crush resistance 2.0 (short term) / 1.0 (long term) kN/100mm
Min bend radius 180 (full load) / 90 (no load) mm
Temperature range
installation 0 to +50⁰C
⁰Cstorage -20 to +70⁰C
operation -10 to +70⁰C
SM@RTCORE CENTRAL TUBE FIBREOPTIC CABLEAll dielectric loosetube fibre optic cable for external underground installations in ducts or direct burial in open-cut trenches, and designed to withstand rodent attack. Low-viscosity gel-filled fibre tubes. Advanced cable design and manufacture has enabled greatly reduced cable size, offering many benefits for both installers and network owners. Glass fibre reinforced plastic non-conductive central strength member and armour rods, UV stabilised Polyethylene / Nylon sheath.
PE sheath with Nylon outer jacket
• Central loose tube construction • Thermoplastic tube with up to 24 fibres filled with a low• viscosity, thixotropic, non-melting gel• GRP peripheral strength members with super-absorbent coating material• Water swellable elements (dry-core) for water tightness• UV stabilised LSZH sheath or UV stabilised polyethylene sheath with bonded nylon outer jacket• Two ripcords beneath sheath for easy removal
FEATURES • Reduced diameter, smaller cable
cross section, high fibre density
• Central loose tube construction, with fibre counts from 2 to 144
• Internal dry water blocking technology
• Termite resistant
• Low duct hauling friction
• UV stabilised LSZH or PE sheath
• UV stabilised polyamide (Nylon) outer jacket
APPLICATIONS• External underground duct
installation
• Direct burial
CABLE DESIGNLSZH sheath
LOOSE TUBE FIBRE OPTIC CABLE | JCS TECHNOLOGIES | SYDNEY | MELBOURNE | BRISBANE | PERTH | JCSTECH.COM.AU 7
Packing: New non-returnable timber drums to AS/NZS 2857 with NOLCO-FLEX protectionDelivery Lengths: Std. delivery length 4 km with a tolerance of -1%/+3%; Total Weight 430kg
MECHANICAL CHARACTERISTICS
F L C – X X – X X – X – X X X X
FIBRE TYPE
FIBRE CORESCABLE LENGTH (m)
SHEATH MATERIAL
06 12 24
Z - LSZH (Low Smoke Zero Halogen)P - Polyethylene / Nylon
M1 - OM1M3 - OM3S1 - OS1S2 - OS2
ORDERING INFORMATION
SM@RTCORE CENTRAL TUBE FIBREOPTIC CABLE IDENTIFICATIONIDENTIFICATION
Sheath Colour: The outer sheath colour is blue.Sheath Marking: The outer sheath is marked in 1 meter intervals as follows:
No. Colour1 2 3 4 5 6 7 8 9 10 11 12
blue orange green brown grey white red black yellow violet pink aqua
No. Colour13 14 15 16 17 18 19 20 21 22 23 24
blue orange green brown grey white red white yellow violet pink aqua
Fibre and Buffer Tube Colours
00
69
-042
016
Parameter Test Method Test Conditions Acceptance Criteria
Tensile strength IEC 60794-1-2-E1Load per cable max tensile strength
max fibre strain < 0.6%/30mins∆ attenuation < 0.1dB
Crush IEC 60794-1-2-E310/120 min, load per max crush resistance, 3 adjacent sections
No sheath or core damage∆ attenuation < 0.1dB
Impact IEC 60794-1-2-E4Wt: 1.5 kg, Ht: 1.0 mAnvil Ø: 25 mm, Impacts: 1
No fibre, sheath or core damage∆ attenuation < 0.1dB/5 mins
Torsion IEC 60794-1-2-E7Tension: per cable spec. Rotation / 1m: 1 turn clockwise / 1 min. and 2 turns anti-clockwise / 2 mins.
No fibre breaks, no sheath or core structure damage. ∆ attenuation < 0.1dB
Bend IEC 60794-1-2-E11 Mandrel Ø: 180mm, 1 turn ∆ attenuation < 0.1dB
Bend under tensionConcurrent totensile testIEC 60794-1-2-E18
Mandrel Ø: 360mm, 1 turn
After 1 minute no fibre breaks, no sheath or core structure damage. ∆ attenuation < 0.1dB from no load to full load
Temperature cycling IEC 60794-1-2-F1Min. sample length: 1000m–10⁰C to +70⁰C
no avg. attenuation increase /∆T. No fibre attenuation > 0.15dB/km
Water penetration IEC 60794-1-2-F5B Length = 3m, Water ht. = 1m No water leakage after 24 hrs.
8 LOOSE TUBE FIBRE OPTIC CABLE | JCS TECHNOLOGIES | SYDNEY | MELBOURNE | BRISBANE | PERTH | JCSTECH.COM.AU
COMPACT AND MEDIUM JOINT CLOSURESThe Compact Multi Function Joint (CMJ) and Medium Multi Function Joint (MMJ) are fibre cable jointing dome closures. Ideal for use as Cable Chamber Joints, Track Joints, Spur Joints or Distribution Joints due to their capacities (144 /288 fibres) and compact sizes. Each factory fitted splice tray can accommodate up to 12/24 spliced fibres.
An optional multi-functional bracket enables vertical or horizontal wall or pole mounting. The joint has four circular ports for mechanical entry glands, one oval port for heat shrink or mechanical entry and two additional small circular ports also for heat shrink entry.
• Single Entry Gland Kit
• Multi Way Entry Gland Kits
• Oval Port Entry Kit
• Silicone Grease
• Emergency Port Cable Entry
• Optical Splitters
• Splice Protectors
• Mounting Bracket / Support Tool
FEATURES • 12 splices / 12/24 single element trays
provides max capacity 144/288 fibres
• Each single circuit tray has 2 sections giving 24/48 total trays per joint
• 4 splices / tray gives 192 fibres capacity
• Suits Ø 1.3 x 30mm splice protectors
• Entry ports accept Ø20mm cables
• Emergency ports accept Ø12mm cables
• Multi way cable entry glands
• Hinged splice trays for full live access
• Accommodates splitters to 64 port
• Pole/wall mounting bracket
• Optional pressure test valve
• Integrated loop storage basket• 01 x Base
• 01 x Cap
• 01 x Clamp
• 01 x O Seal
• 02 x Tube Retainer
• 04 x Tube Retainer Cover
• 24 x SE Splice Trays
• 01 x Loop Storage Basket
• 01 x Pole / Wall Bracket
• 01 x Fibre Routing Manifold
LOOSE TUBE FIBRE OPTIC CABLE | JCS TECHNOLOGIES | SYDNEY | MELBOURNE | BRISBANE | PERTH | JCSTECH.COM.AU 9
The CMJ/MMJ is supplied with:
KIT CONTENTS
ADDITIONAL ITEMS
COMPACT AND MEDIUM JOINT CLOSURES SPECIFICATIONS
ParameterValue
CMJ MMJ
Minimum Fibre Bend Radius 20 mm
Number of Cable Ports 4 circular and 1 oval plus 2 small emergency ports
Cable Ø Range (mm)
Circular Port 7 to 20 mm
Multi Port (in circular port) 5 to 7 mm (4 Way), 3x2mm flat cable (8 Way)
Oval Port 7 to 21 mm (Heat Shrink), 7 to 15 mm (mechanical)
Emergency Port 4 to 12 mm
Cable Retention (N):
Circular Port > (Cable Ø/45) x 1000 N, strength member secured
4 Way Multi Way (in circular port) > 150 / 30 N for cables with / without Aramid yarns
Maximum # of splice trays12 Single Element 24 Single Element
12 single Circuit Double Trays 24 single Circuit Double Trays
Maximum fibre capacity of Joint144 Single Element 288 Single Element
96 Single Circuit 192 Single Circuit
Splitter capacity 4 optical splitters of 4mm x 4mm x 60mm
Required space envelope (L) 290 x (W) 231 x (D) 164 mm (L) 380 x (W) 231 x (D) 164 mm
Operating temperature -40⁰C to + 70⁰C (5 to 95% RH)
Packing Dimensions (L) 480 x (W) 250 x (D) 210 mm
Packed weight 2.4 kg
Net weight 1.9 kg
Material
Cap/ Base GF Polypropylene
Clamp GF Nylon
Splice Trays FR ABS
Testing
Closure Sealing IP68 (5 metres) (IEC 61300-2-23)
Optical Tested 1310nm,1550nm and 1625nm
Change of Temperature IEC 61300-2-22
Dry Heat BS EN 60068-2-2 Test Bb
Damp Heat IEC 60068-2-3: 1969
Vibration IEC 61300-2-1
Torsion IEC 61300-2-5
Bending IEC 61300-2-37
Impact IEC 61300-2-12
Cable Retention IEC 61300-2-4
Crush Resistance IEC 61300-2-10
Item Description Order Code
Compact Joint Closure (CMJ) Fibre cable jointing dome closure 290mm height / 144 splice capacity FEP-CMJ
Medium Joint Closure (MMJ) Fibre cable jointing dome closure 380mm height / 288 splice capacity FEP-MMJ
ORDERING INFORMATION Contact JCS regarding additional items such as cable entry kits, splitters and splice protectors.
10 LOOSE TUBE FIBRE OPTIC CABLE | JCS TECHNOLOGIES | SYDNEY | MELBOURNE | BRISBANE | PERTH | JCSTECH.COM.AU
LARGE JOINT CLOSURESThe Large Multifunction Joint (LMJ) is a large dome closure for optical cable splicing, ideal for track, spur and loop access applications in the external optical network. With two vertical tray stacks, it can accommodate a wide variety of cables such as loose tube, central loose tube, Flextube and blown fibre.
The modular tray system is designed for positive fibre management for Single Circuit Management (SCM) and Single Element Management (SEM), and the splice trays can accommodate a variety of splice protectors and splitters.
The joint has ten circular ports and one oval port for mechanical entry. Mechanical glands are used to seal cables into the circular ports. Multi way glands are also available to fit multiple cables into each circular port.
The LMJ is supplied in three different sizes to suit required splice capacity.
FEATURES • 1344 fibre capacity
• 2688 fibre capacity using 24 fibre trays
• Different cap lengths to configure tray capacity
• Mechanical oval port and loop storage for up to 276 fibres using loose tubes (Loop capacity 3.4m of 23 elements, Ø2.2mm)
• Suits Ø 1.3 x 30mm splice protectors
• Circular entry ports accept Ø23mm cables, oval port accept Ø18mm
• Multi way cable entry glands
• Hinged splice trays for full live access
• Accommodates splitters to 64 port
• Pole/wall mounting bracket
• Closure sealed to IP68
• Oval Port Entry Kits
• Splicing Modules
• Splitter Modules
• Splice Protectors
• Mounting Brackets
• Circular Port Gland Kits
• Closure Upgrade Kits
ADDITIONAL ITEMS
LOOSE TUBE FIBRE OPTIC CABLE | JCS TECHNOLOGIES | SYDNEY | MELBOURNE | BRISBANE | PERTH | JCSTECH.COM.AU 11
The LMJ is supplied as an empty closure with a cap, a base, a clamp, a sealing gasket and a support frame. Cable entry kits, splice trays and accessories are ordered separately as required. The closures can also be preconfigured upon request.
KIT CONTENTS
LARGE JOINT CLOSURES SPECIFICATIONS
ORDERING INFORMATION
The LMJ is a modular system. Please contact JCS for custom enclosure configurations and for the wide range of accessories available.
ParameterValue
LMJ Short Cap LMJ Medium Cap LMJ Long Cap
Minimum Fibre Bend Radius 30 mm
Number of Cable Ports 10 circular and 1 oval
Cable Ø Range (mm)
Circular Port 4 to 23 mm
Multi Port (in circular port) 5 to 9 mm (4 Way), 3x2mm flat cable (8 Way)
Oval Port 6 to 18 mm
Cable Retention (N):
Circular Port > (Cable Ø/45) x 1000 N, strength member secured
4 Way Multi Way (circular port) > 150 / 30 N for cables with / without Aramid yarns
Capacity for Single Element Management (SEM) 12f per tray and 24f per tray
Maximum number of trays 48 (24 + 24) 80 (40 + 40) 112 (56 + 56)
Maximum splices – 12f tray 576 960 1344
Maximum splices – 24f tray 1152 1920 2688
Capacity for Single Circuit Management (SCM) 4f per tray
Maximum number of trays 96 (48 + 48) 160 (80 + 80) 224 (112 + 112)
Maximum splices 384 640 896
Required space envelope (L) 493x(D) 250 mm (L) 600x(D) 250 mm (L) 721x(D) 250 mm
Operating temperature -20⁰C to + 60⁰C (5 to 95% RH)
Material
Cap/ Base GF Polypropylene
Clamp GF Nylon
Splice Trays FR ABS
Testing
Closure Sealing IP68 (5 metres) (IEC 61300-2-23)
Optical Tested 1310nm,1550nm and 1625nm
Change of Temperature IEC 61300-2-22
Dry Heat BS EN 60068-2-2 Test Bb
Damp Heat IEC 60068-2-3: 1969
Vibration IEC 61300-2-1
Torsion IEC 61300-2-5
Bending IEC 61300-2-37
Impact IEC 61300-2-12
Cable Retention IEC 61300-2-4
Crush Resistance IEC 61300-2-10
JCS TECHNOLOGIES PTY LTD | www.jcstech.com.au | U1, 5-11 Mellor Street, West Ryde NSW 2114T: +61 2 8878 6600 | F: +61 2 9808 2622 | E: [email protected]
00
69
-042
016