LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced...

63
www.yinuochina.com

Transcript of LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced...

Page 2: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

YINUO’s Dream:

Rise Chinese flag

Create national brand

Produce global products

Page 3: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Instrumentation & Pump

Collecting technology from all over

the world and then made in China

Page 4: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Application

Page 5: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Sales network all over the world

Page 6: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

History

Page 7: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

History

Page 8: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed
Page 9: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

• 1993~2003 Years➢ Established the first factory at Panjin in 1993

➢ Developed and produced Double Rotator Flowmeter in 1995

➢ Developed and produced Flow auto controller in 1997

➢ Developed and produced High pressure Flow auto controller in 1998

➢ Established the second factory at Jiading District , Shanghai in 1999

➢ Constructed the oil/water/oil calibration plant in 2000,2001,2002

➢ Got the CCS cert. for PD flowmeter in 2003;

History

Page 10: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

•2004~2017 Years•Got the BV of France for YINUO company in 2004

•Became the First Level Supplier of CNPC and Sinopec in 2005

•Developed and produced Mass Flowmeter in 2006

•Established the third factory in Songjiang, Shanghai in 2008

•Established the Emis-Yinuo (Russia) Joint Venture company in 2008

•Established the Yinuo-Korvet (China) Joint Venture company in 2010

•Developed and produced Ultrasonic Gas Flowmeter in 2011

•Established the GPE factory in 2011

•Developed and produced Multi-phase measurement equipment in 2013

•Got the UL cert. for Coriolis mass flowmeter in 2016

•Got the CE cert. for Vortex, Ultrasonic, Electromagnetic flowmeter in 2017

Page 11: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Who we are?• As a joint-stock company, we have

5 companies and 3 factories:

• Shanghai Yinuo Instrument Co., Ltd. (factory in Jiading)

• Shanghai Yinuo Kovert Pump Co., Ltd.

• Shanghai Yinuo Automation Engineering Co., Ltd.

• Shanghai Nuoly International Co., Ltd.

• Panjin Branch (factory in Northeast of China near oilfield)

• EMIS-YINUO LLC (In Chelyabinsk of Russia).

(factory in

Songjiang)

Page 12: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Who we are?

• There are total in 398 staffs and more than 55% of them are

bachelor degree or above. There are 18 senior engineers and 50

engineers of them.

Page 13: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

What we do?Shanghai Yinuo Instrument Co., Ltd.is a leading manufacturer of flow

measurement and control instruments.

Shanghai Yinuo-Kovert Pump Co., Ltd. is professional pump manufacturer.

Shanghai Yinuo Automation Engineering Co., Ltd. is a famous

project/system contractor who focuses on automation loading system or

engineering.

Shanghai Nuoly International Co., Ltd. focuses on international trading of

electricity meter/power meter, ZigBee for housing, some parts of instrument or

pump, etc.

Page 14: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Achievements in the past 9 years

Sales Amount

• The sale Volume has been

growing at average rate of 20%.

In 2015, the annual sales

reached RMB330 million (about

USD52million).

2005, 20.4

2006, 120

2007, 210

2009, 2402010, 250

2011, 2702012, 280

2013, 2902014, 300

2015, 330

2008, 220

0Million

50Million

100Million

150Million

200Million

250Million

300Million

350Million2005

2006

2007

2008

2009

2010

2011

2012

2013

2014

2015

2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015

Page 15: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Certificates

ISO9001/ISO14001/OHSAS18001

Page 16: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Certificates

12 invention

patents and 38

utility model

patents

Page 17: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Certificates

Page 18: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Certificates

HART Registered

cert for LZYN-

Coriolis Mass

flowmeter

Page 19: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Certificates

BV & CCS for the Marine

Page 20: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Certificates

National Key New Product

Certificates

GLZ-high pressure auto-controllerLSZ-Double rotator (Gas) flowmeter

LZYN-Coriolis mass flowmeter

Page 21: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Production FacilitiesOur 3 manufacturing factories includes total 48,000 m2 area with 36000 m2 building.

We had gotten the ISO9001:2000 quality system certification and all delivered products are manufactured and tested according to this quality system.

We have three R&D centers: Electronic + Mechanical + Automation system R&D center.

We have advanced machining center, Computer Numerical Control (CNC). All core parts are all completed in CNC processing center and the whole flowmeter will be tested by calibration.

Page 22: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Production Facilities

Automatic Micro-bending Machine

Good parallelism could be ensured by the

whole control

THE ACCURACY OF the bending angle

could be controlled within ±0.1° The repeatability of micro-bending could be

ensured

Page 23: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Production Facilities

Automatic Chip Mounter (Surface Mounting Technology)

The reject rate can be

controlled under 0.01‰

Small volume and high

mounting density

High frequency

characteristics, EMI and RFI

could be reduced

High reliability and shock

resistance

Page 24: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Production Facilities

Creative Assembly and detecting System

The vibration can be observed clearly

Vibration transmission can be eliminated

The system is to boost efficiency and the passing rate

Page 25: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Production FacilitiesAutomatic Welding Machine

1. High welding quality

2. High yield

1. High welding quality 2. High yield

Page 26: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Production Facilities

Gas Calibration Lab.

Water-Based Gravimetric

Calibration Lab.

Oil Calibration Lab.

Calibration system

Water calibration Lab., from DN10-600mm, and calibrated by electric scale;

Oil calibration Lab.: from DN8-400mm, the biggest system in East of China, highest accuracy is 0.1%;

Gas calibration Lab.: sonic nozzle principle, to test the meter from DN25-300mm.

Page 27: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Sub: Mass Flowmeter Micro-bent shaped

Features

• Coriolis Flow Measurement Technology

• Multivariable capability for mass flow rate, volume, density and temperature measurement

• Rugged, robust meters with no moving parts result in minimal maintenance or repair

• Accuracy over a wide flow range from a single meter optimizes plant efficiency

• No flow conditioning or straight pipe runs required making installation simplified and less expensive

• Widest range of Coriolis, density, concentration and net flow measurement devices available

Page 28: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Construction

• Part 1: Transmitter

General anolog

transmitter(Series G)

DSP transmitter

(Series D)

Features

• Digital signal processor transmitter for high sampling and larger turn-down ratio

• Electrical fast transient & Surge immunity test got electromagnetic compatibility A according to ICE61326

Page 29: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Construction

Type 1: Triangle Shaped

Size from ½” to 1”

Type 2: U- Shaped

Size from 1 ½ ” to 8”

Type 3: Micro-bent Shaped

Size from 1/8 ” to 12”New!!

Super bend: from DN50-100

Page 30: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Main Specification

Size: 3/8” to 12”

Flow range: 50-1,500,000kg/hr

Max. process pressure: Up to 250bar

Max. process temp.: Up to 250℃

Process connection: GB, DIN, ANSI, ASME, JIS, etc.

Communication: 4-20mA; Pulse/Frequency; Modbus RTU( RS485); HART

communication protocol

Sensor: Triangle shaped, U shaped , Micro bent shaped.

Transmitter: DSP digital

Electric interface: M20*1.5 /G ½” or Customized

Explosion proof: Exib II CT3-T6 ( NEPSI; GOST)

Page 31: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Multi-functionDirectly measured values:

1. Mass flow

2. Density

3. Temperature

and then calculate Volume flow

Various Configuration between

pulse and 4-20mA for above values

Bi-direction Measurement

Water-cut oil @ API 15℃

4. Oil/water ratio analysis

Page 32: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Application- Marine

Page 33: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Application- Loading & Uploading

12 sets LZYN-Coriolis mass flowmeter in military project, and measure the oil

from tank to airplan.

Page 34: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Application- Oil Plant

Page 35: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Features Superior accuracy - to 0.1% of reading over 30:1 turn-down

Uniform rotation means low pressure loss

No metal-to-metal contact provides for long service lifetime

Self-lubricating

Very low noise and vibration

Reduced number of parts reduces maintenance requirements

Rugged double case construction prevents loss of calibration

due to changes in pressure or temperature More+

LSZ-Double rotator Flowmeter (PD Meter)

Page 36: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

LSZ-Double Rotator Flow meter (PD

Flow meter) is made up of the housing

and two special rotors, transmission

components and mechanical or

electrical register.

WORKING PRINCIPLE

Page 37: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Features- Register For option

VR-7886

Mechanical

Round

Mechanical

• Veeder Root-7886 Mechanical Register

• Electronic Ex-proof type LCD , water-proof

Register

• Round dial Mechanical

• EMR3 Electronic Meter Register

Page 38: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Feature comparing

High accuracy and

repeatability

Low noise

Low pressure loss

Pulse-free for longer lifetime

Comparing with

other kinds of

PD Flow meter,

double rotator

flow meter

means

Page 39: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Application

Double

Rotator

(PD Meter)

Ship

Building

ChemicOil

filed& Refinery

Loading&

Metering

Page 40: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

IntroductionLBYN series scrape-board flow meter

(Also called Rotary Vane Flow meter) is

a newly type, particular-designed,

precisely process and assembling

positive displacement flow meter. It

has only one rotator, circling with

uniform velocity.

LBYN-Scrape Board (rotary vane) Flowmeter

Page 41: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

LBYN-Scrape Board (rotary vane) Flowmeter

Feature

1. Superior accuracy to ± 0.1%.

2. Smooth running and low noise and

vibration

3. Long service lifetime

4. Can match with photoelectric generator

for signal output

5. Double cases and Low pressure Drop

Size 1” to 16”

Max. Process pressure 63bar

Max. Process Temp. Up to 200℃

Register VR7886/ Round dial register/ digital register

Output Pulse/4 to 20mA; RS485( for digital only)

Accuracy Up to +/-0.1+%

Page 42: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Application

Page 43: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Ultrasonic Gas flowmeter

FeatureSize: DN25~300mm

Pressure : 10Mpa

Accuracy: ±0.5~1.5%

Medium T: -40~+85C;

Output signal : Pulse, 4-20mA, RS485;

Turn down ratio: 1:30-1:50

No pressure loss;

Double direction measurement;

Better anti-interference function;

Water proof

Special transducer designing for impurity gas;

Page 44: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Compare with gas turbine, vortex, gas rotary, and Differential pressure

flowmeter, it the following advantages:

1.Wide flow range :1:30;

2.Low flow velocity to 0.001m/s;

3.Self-diagnostic function(Inner parameters,

transducer etc)

4.Double direction measurement;

5.No pressure loss;

6.Better anti-interference function;

7.Alarm;

Advantages

Page 45: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Application

Various Energy gas & Industry gas under middle or low flow range

Page 46: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

LXW-Vortex Flowmeter (High Pressure)

DSP transmitter

DN15~300

Compact structure for high temperature(up to 300℃), High pressure(up to 320bar), Temperature and/or Pressure compensation

Service for steam and gas, liquid. +More

Page 47: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

MAGYN-Series Intelligent

Electromagnetic Flowmeter (High Pressure)

Accuracy: 0.3%, 0.5%,1.0%

DN15~3000

PN16~420bar

Ambient magnetic field:≤400A/m

Liquid Conductivity:5u/cm

Output Signal:4~20mA, Pulse output,RS485

Alarm Output:Alive

+More

Page 48: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

LTD-General electronic flowmeter

(Tangential Turbine)Anti-impurity, anti-jammed

High Pressure(max. 420bar)

Easy installation and discharge

Local LCD display for instant flow and total flow

Power supply: 3.6V lithium battery, 24VDC

Signal output for long-distant transmit:

Analog 4~20mA, Pulse/, RS485.

Service: Water, wastewater, low viscosity oil, etc.

Reference: Iran, Russia, CIS, Africa, South America

.

+More

Russia,

Page 49: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

GLZ Series High Pressure

Flow Auto Controller

IntroductionThe flow meter parts of GLZ Series Higher Pressure Flow Auto Controller are made up of

impeller, shaft and bearing which has been specially machined. So it has strong function of

fouling prevention to the waste water in the oilfield. Meanwhile, the impeller bracket can be

easily taken out from the body of the meter, which brings many conveniences for the meter’s

periodical test. The controlling and executive part of the flow valves is alternating electromotor

which has been passed decelerator device. With manual device and interior battery, the GLZ can

work normally when alternating current is cut down. And the hand-wheel is so light that the

distinguish ability ratio is high under the function of decelerator device. The application of

advanced electric technology makes the whole controller the higher stability and anti-jamming

capability. +More

Page 50: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

XJB-Screw Rotor Pump

Working Features:

Low power consumption , High capacity ,

good energy-saving performance

Russia aerospace seal technology

1.5~2.5 times capacity than common pump

1.5~3.0 times Suction height than common pump

30-50% energy conservation than the normal rotor

pump in the same flow capacity

More small Mass and outlet size than common pump

Special alloy rotor with high wear resistance

Working and functioning in cavitations

Page 51: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Application

Page 52: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

2GS Series Twin Screw Pump( double suction)

High head

Low noise

Resistant impurity

Suitable for high viscosity medium

delivery

Self-priming, high suction

1. 2GS Series screw pump is independent

researched by Nuoko Pump Co.,Ltd and

gets 2 Chinese invention patents, 5

patents of utility model.

2. Screw pump is divided into single screw

pump ,two screw pump, double suction

two screw pump and three screw pump,

we manufacture single suction double

screw pump and double suction double

screw pump.

3. Principle of screw pump: Motor drive

several rotors operating in pump cavity,

fluid sucked from one side, and discharge

to other side (Double suction screw suck

fluid from both ends, and discharge in the

middle). Pressure increasing and drive

fluid delivery. There is sealing face

between rotators inside and shell, in which

the flow is transited in a certain unit like by

a spoon, so screw pump is a kind of

positive displacement pump.

Page 53: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Packing

Page 54: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Application

Page 55: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

YQSJL-YN Multi-phase separation measurement equipment

SEVEN FEATURES!!!

Break gas thoroughly

Boost pressure through pumping

Easy to measure with high accuracy.

High automation

Remote communication to connect with

the oilfield network.

Skid-mounted for easy installation

and application

Two years full tracking service

THREE GAS SEPERATION WAYS

Cyclonic gas separation

Bubble-hitting gas separation

Negative pressure burst gas

separation

Page 56: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Live Operation Software

Page 57: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

History record

Page 58: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

On site applicationUser feedback report

Page 59: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

QZ Skid Mounted Loading ﹠ Metering System

PD Meter

Filter and Gas Eliminator

Mass

Flowmeter

Batch Controller

Page 60: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Afghan crude oil Loading & Metering 2 channels 4 sets SKID systems

Process: key parts manufacturing, assembly, painting,

container delivery, installation and comissioning in the field

Page 61: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Equatorial Guinea Project:two oil depots loading & metering system

Page 62: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Advantages of YINUO(1) For electronic products, we have automatic chip mounter (Surface

Mounting Technology) production line and high/low temp. testing equipment.

(2) For mechanical products, we have advantage on casting, machining, and

welding which is the key point in eyes of Russian.

(3) For calibration, we have calibration facilities approved by China

government for oil, water and gas.

(4) For flowmeter, we are Top leaders in China for both of PD Meter and

Coriolis Mass Flowmeter, we got CE certificates, CCS certificate (China) and

BV certificate (France) for marine market.

(4) For pump, we combined Russian military technology with China low cost to

manufacture for large capacity transportation of oil, chemical, water, and

wastewater even if contain some participles and we also design and produce

twin-screw pump for high pressure, high viscosity liquid with multiphase.

(5) For SCADA loading & metering/ Skid Mount System, we also have much

experience in China and in Afghanistan, Equatorial Guinea and are trying to

promote in all over the world.

Page 63: LOGOapcse.com/wp-content/uploads/2017/08/03-2017-YINUO... · 2017-08-04 · Developed and produced Flow auto controller in 1997 ... at Jiading District , Shanghai in 1999 Constructed

Thank you four attention and expect your cooperation!

For any question, Please contact us:

[email protected]: +86-21-39531213

Website: www.yinuochina.com