LOGO! 8 - IntroductionFor internal use only / Siemens AG 2012. All Rights Reserved.1LOGO! 8 News Roadmap LOGO! 8LOGO! 8 Hardware, functionsLOGO! Soft Comfort V8 Improvements / NewsExercisesFor internal use only / Siemens AG 2012. All Rights Reserved.2Roadmap LOGO! 8 and LSC V8Q1032014Q2062014Q3092014Q4122014Q1032015Q2062015Underdevelopmentplannedavailable

HMI 2014Light & Building 2014

08/2014LOGO! TDE+ 2 Ethernet Ports+ 6 Lines, 3 background colors

LOGO! Soft Comfort V8+ Single-Program and Network Mode+ automatic IP assignment + Web-Server + Data exchange via D&D

LOGO! 0BA8all BM and EM+ Micro SD-Card+ TD based Web-Server+ add. 4 outputs Q17 Q20+ 8 AQ+ 6 Lines, 3 background colors

LOGO! App V3+ for LOGO! 7 and 8+ I/O Table+ Upload Datalog file+ access protection via PW

LOGO! CMR 2020

3LOGO! 8 News+ New design for all BM and EM+ Complete BM family of 8 BM (like LOGO! 6)+ All expansion modules (like today but not compatible with old EM/BM)+ all LOGO! BM & EM in one release+ New LOGO! TDE+ Communication with: KNX, CSM, GSM (AS-I not planed yet)+ New design for LOGO! Power

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.20144

LOGO! 8 Hardware

+ 4 TE housing like LOGO! 6+ standard Micro SD-Card+ captive cover (cant get lost)+ new display+ 6 lines (16/10 characters per line)+ 3 background colors (white, amber, red)+ additional functions+ adjustable startup time+ new menu structure+ add. outputs Q17 .. Q20 + add. Analog outputs AQ 3 ..8+ Dataloging to MSD-card max. 20.000 records in one file

All LOGO! 8 BM and EM in one release (except KNX/EIB)Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.20145LOGO! 8 Hardware

Attention: When migrating a program you must add the IP address of the new LOGO! TD and the target LOGO! IP-Adr.New display:+ 6 lines, 20/24 characters per line+ 3 backlight colors (white, amber, red)+ 2 Ethernet ports+ 3 pin standard power connector+ selection list for target LOGO! BM+ Operator / Admin modeNur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.20146LOGO! 8 Hardware

LOGO! 8 TDE: Two LOGO! connected to the two Ethernet port:Selection to which LOGO! the TDE shouldcommunicate and show the message texts

LOGO! 8 TDE: A LOGO!8 and a PC connected to the two Ethernet port:Communication of LOGO! Soft Comfort V8and the TDE possible at the same time.

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.20147LOGO! Soft Comfort V8 InstallationLOGO! Soft Comfort V8Free update via LOGO! Internet page or via Help / Update CenterSupports all actual operating systems (Windows, Mac and Linux)Available languages:+ German+ English+ Italian+ French+ Spain+ Chineseother languages possible via DDK translation in the regionsSupports all LOGO! version (0BA0 .. LOGO!8)

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014LOGO! Soft Comfort V8 InstallationInstallation of the pilot version of LOGO! Soft Comfort V8:

Copy the complete folder to your local hard disk. Open the folder of your operating system (Win, Mac or Linux)Windows: change to the right folder based on your installation (64 or 32 Bit)Execute the file:LOGOComfort.exe

Not when LSC V8 is released!Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014LOGO! Soft Comfort V8: Diagram Mode

1237451. Menu bar2. Standard Toolbar (fix)3. Program mode4. Program Toolbar (fix)5. Program Editor6. Status bar7. Diagrams8. Function blocks 68

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014LOGO! Soft Comfort V8: Diagram Mode

2Program toolbar- selection- connect- cut/join connection- comments- align automatically - align horizontal- align vertical- bring to front- send back- Undo- Redo- constants connectors- basic functions- special functions- Data-Loging

- undo split- split into two windows- split into three windows- zoom in- zoom out- select lines- page layout- convert to LAD/FBD- simulation- online-Test- show reference lines - expand parameter boxes- hide parameter boxes

3

4Standard Toolbar: separate icons for RUN/STOPProgram mode:Change from diagram to network mode

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014Connect to LOGO! in Diagram modeNur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014

LOGO! Soft Comfort V8 : Connect to LOGO! Diagram mode15Interface selection(Ethernet, Com-Port, USB)Interface number (if more then just one is available)Target IP-Address of LOGO! 8Scan for available devicesList of available devicesCheck connection to target LOGO! (3)2346

Benefit: Automatically set/reset of the Ethernet interfaceExercise: Connect to LOGO! using automatic IP assignment with different IP-Addresses of LOGO!Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014Please note:If the search of connected devices dont work, then:Disable addition Ethernet connection to other networks then to the network where LOGO! is connected.In regular Windows installation (without the Siemens CAT Enterprise installation). Select the right Ethernet interface where LOGO! is connected to. (Windows operating system always have a preferred Ethernet interface. So it requires to select the right Ethernet interface)If you know the IP-Address of the LOGO! then you can also add it to the address book, or you can enter it as the target IP-Address.

13Migration from older LOGO! Programs to LOGO! 8Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014

LOGO! 8: Migration from LOGO! x LOGO! 8Migration from older LOGO! Programs to LOGO! 8File/open Select file and press open21

Exercise: Open an old LOGO! program and migrate to LOGO! 8 including __Web-Server.

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014

Migration from older LOGO! Programs to LOGO! 81. Change hardware to LOGO! 81

2LOGO! 8: Migration from LOGO! x LOGO! 8Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014

Migration from older LOGO! Programs to LOGO! 81. Check properties of message texts2. Select messages for Web-Server3. Download program to LOGO! 81

2LOGO! 8: Migration from LOGO! x LOGO! 8Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014

Migration from older LOGO! Programs to LOGO! 81. Open the file properties File/Properties2. Enable Web-Server and specify a Password for Web-Server login1

2LOGO! 8: Migration from LOGO! x LOGO! 8Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014

Migration from older LOGO! Programs to LOGO! 8Add your LOGO! 8 IP-Address to connect to the integrated Web-ServerSelect the view you need+ LOGO! System+ LOGO! Variables+ LOGO! Base module+ LOGO! TDE

1

2LOGO! 8: Migration from LOGO! x LOGO! 8Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014LOGO! 8 Migration from LOGO! x to LOGO! 8

+ with all common PC Web-Browsers(Internet Explorer, Chrome, FireFox, )+ with all Smartphones (optimized resolution)(Android, iOS, WindowsPhone, . with common Internet browser (Opera, Chrome, .)+ with all Tablet PCs (optimized resolution)(Android, iOS, Windows, with common Internet browser)Program itSelect itEnable itOpen itSupported operation:+ Parameter changes configured in a message text+ Cursor buttons at LOGO! BM or LOGO! TDE used in the LOGO! Program+ LOGO! TD function keys used in the LOGO! Program

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014New in LOGO! Soft Comfort V8Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014

LOGO! Soft Comfort V8 : Referencing132Additional icon for shown referencinginformation- Expand all parameter boxes- Collapse all parameter boxes- Show reference lines

Reference in LOGO! Soft Comfort V8- Parameter box of FB- Reference done like wiring of signal

Benefit: Better documentation, diagnostic and overview of referenced values

Referencing up to V7 via FB-SelectionExercise: Create a program for LOGO! 8 using an analog amplifier as a reference for an Off-Delay.Change HW between LOGO! 6/7 and LOGO! 8 Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.201422LOGO! Soft Comfort V8 : Special flags13Direct selection of special flags from the listClear separation color of special flagsSet color for special flag in Tools/Options/Colors2Benefit: Simple to program and clear differentiation of special flags via different color

12

Exercise: Change the color for the special flags.Create a program including special flagsExercise 2: create a program where a service telephone number is shown on the displays with flashing red background color.Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.201423

New:Additional delay time for sunrise and sunset.Benefit: Individual setting depending on the application (light control, animal breeding, ..) LOGO! Soft Comfort V8 : Astronomical clockExercise: Create a Program for LOGO! 8 with some astronomical clocks with different delays and simulate it.Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014

Weekly timer:All settings in one dialogBenefit: Simpler to configure and better overview of the settings

LOGO! Soft Comfort V8 : Weekly timerExercise: Create a Program including a weekly timer and simulate it in LOGO! Soft ComfortNur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014

Access Control settings:Remote access for LOGO! Soft Comfort V8LOGO! Soft Comfort (Telelservice)Access control for LOGO! AppAccess control for Web-ServerLOGO! TDE Menu (Admin / Operator mode)Benefit: Separate access control and PW for all remote connections

LOGO! Soft Comfort V8 : Access control settingsNur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014

I/O Settings:Configuration for onboard analog input at a LOGO! Base module:+ Disabled (for 8 PT100/1000)+ 2 AI (Default)+ 4 AI (max.)Benefit: Up to max. 8 temperature measures for all LOGO! 8 Base modules

LOGO! Soft Comfort V8 : I/O SettingsNur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014LOGO! Soft Comfort V8 : Function block positionLOGO! 8 and LOGO! Soft Comfort V8:Same position of FB after program upload. (Requires LOGO! Soft Comfort V8 and LOGO! 8)Benefit: Better diagnostic because of same FB position after upload

Upload LOGO! 7Upload LOGO! 8

Exercise: Download and upload some programs to LOGO! 8Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.201428LOGO! Soft Comfort V8: V-Memory in LOGO! 8

V-Memory in LOGO! 8 New addresses. Customer using the LOGO! 7 addresses have to change tiDate & Time information in LOGO! 8New addresses range for date & time.Read / Write supportedNew address rangeDate & Time address rangeExercise: Start simulation and add the addresses for date & time into a data table.

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014LOGO! Soft Comfort V8: DatalogMax 20.000 recordsA new datalog file will automatically generatedon the MicroSD-cardThe last one can be uploaded by LOGO! Soft Comfort V8Record to internal memory same as LOGO! 7Benefit: Long term recording with automatically created new datalog record. New data logging with LOGO! 8

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014LOGO! TDE Admin / Operator modeNur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014LOGO! TDE Admin / operator modeWith * marked points can not be selected in Operator mode.Most important limitations in operator mode:- RUN / STOPP- Program changes- Program name- Password changes- All functions related to MSD-CardBenefit: Password protection for accidentally changesLOGO! TDE : Admin / Operator mode

* Start* Program Setup Network Diagnostic* Card

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014

Access control setting:Remote access for LOGO! Soft ComfortAccess fro LOGO! App V3Web-Server accessLOGO! TDE Menu (Admin / Operator)Benefit: Separate password protection for remote access and TDE

LOGO! TDE : Admin / Operator mode

Exercise: Enable and configure the TDE Operator/Admin mode and test it.

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014Network modeNur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014

LOGO! Soft Comfort V8 Network Mode: Overview123946Menu barStandard ToolbarProgram modeNetwork ToolbarNetwork viewStatus barProgram editorStatus barNetwork projectFunction blocks 10578

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014

LOGO! Soft Comfort V8: Interfaces1Connection via Dyn-DNS (Internet)- Select Dyn-DNS- Dyn-DNS Name of LOGO! 8- Test connection32

Connection via programing cable - Select LOGO! Cable- Port selection (COM-number / USB)- Test connectionConnection via Ethernet- Ethernet-Interface selection- IP of target LOGO!- Search connected devices- Address book- Test connection to selected device- List of connected devicesNur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014Exercise 1: Connect to LOGO! 8 in network modeExercise 2: Migration of old programs LOGO! 6 / 7 LOGO! 8Exercise 3: Import of programs in network modeExercise 4: LOGO! communication in network mode

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014Exercise 1: Connect to LOGO! 8 in network modeNetwork mode1. Press Go Online to automatically detect connected LOGO! 82. View of connected LOGO! in network view

12

Benefit: Automatically configuration of IP setting to find connected LOGO! devicesNur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014Network mode1. LOGO! device on the network, program part of the network project2. LOGO! device on the network,No program of this LOGO! part of thenetwork project3. Manually added LOGO! Device to thenetwork project.

213

Benefit: Clear identification of devices.Exercise 1: Connect to LOGO! 8 in network modeNur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014Exercise 3: Add programs to a network project

Add programs to a network project:Via D&D from Diagram Network ModusOnly programs for LOGO7 or 8 can be added.Programs for older LOGO! must change indialog mode firstVia direct Import

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014Exercise 4: Data transfer with LOGO! 8

Configuration via Drag & Drop Drag the signal (digital or analogue) from one diagram to another oneClear view of network information.Simplest handling6

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014LOGO! 8 Communication in network modeDifferent devices in network view:PC or PGLOGO! 8 with configured connectionLOGO! 7 with configured connectionS7 compatible device (S7-1200, 300, )Simatic HMI (Basic or Comfort Panel)LOGO! TDE (view only)

1

123465

Shortcut:Link to project file. To start other programing tool like TIA-Portal from LOGO! Soft Comfort V87

Nur fr internen Gebrauch / Siemens AG 2009. Alle Rechte vorbehalten.Industry SectorSeite Nr.21.05.2014Thank you for your attention!H. SchindlerI IA AS FA SB-PRM 3

Phone: +49 (0)911 / 895 - 3665

E-Mail: [email protected] internal use only / Siemens AG 2012. All Rights Reserved.43