LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE Service Information INDEX Installation ............................................................................ 1 Reference Data .................................................................... 2 Multifunction Logic Valve ...................................................... 3-5 15 psi Part No R431005976 (formerly P -062016-00000) 30 psi Part No R431005977 (formerly P -062016-00001) 80 psi Part No R431005980 (formerly P -062016-00004) Hydraulic Pilot Logic Valves ................................................. 9-11 35 psi Part No R431005967 (formerly P -062014-00000) 110 psi Part No R431005968 (formerly P -062014-00001) 220 psi Part No R431005969 (formerly P -062014-00003) Logic Pressure Regulator ..................................................... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part No R431005986 (formerly P -062018-00001) Logic Valves Miniature Shuttle ............................................. 12-14 Part No R431005928 (formerly P -061971-00000) Logic Flow Control Valves .................................................... 15-17 Part No R431005931 (formerly P -061975-00002) Logic Timer ........................................................................... 18-19 (Time In) Part No. R431006335 (formerly P -064003-00000) (Timed Release) R431006336 (formerly P -064003-00001) Multifunction Adjustable Logic Valve .................................... 20-22 Logic Solenoid Valve ............................................................ 23-24 Logic Test Assembly and Disassembly Schematic ....................................................... 25 SM-1200.9200 WARNING - INSTALLATION AND MOUNTING The user of these devices must conform to all applicable electrical, mechanical, piping and other codes in the installation, operation or repair of these devices. Installation! Do not attempt to install, operate or repair these devices without proper training in the technique of working on pneumatic systems and devices, or under trained supervision. Compressed air systems contain high levels of stored energy. Do not attempt to connect, disconnect or repair these products when a system is under pressure. Always exhaust the pressure from an air system before performing any service work. Failure to do so can result in serious personal injury. Mounting! Devices should be mounted and positioned in such a manner that they cannot be accidentally operated.

Transcript of LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator...

Page 1: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

LOGIC VALVE DISASSEMBLY

AND SERVICE REPAIR PROCEDURE

Service Information

INDEX Installation ............................................................................ 1 Reference Data .................................................................... 2 Multifunction Logic Valve ...................................................... 3-5 15 psi Part No R431005976 (formerly P -062016-00000) 30 psi Part No R431005977 (formerly P -062016-00001) 80 psi Part No R431005980 (formerly P -062016-00004) Hydraulic Pilot Logic Valves ................................................. 9-11 35 psi Part No R431005967 (formerly P -062014-00000) 110 psi Part No R431005968 (formerly P -062014-00001) 220 psi Part No R431005969 (formerly P -062014-00003) Logic Pressure Regulator ..................................................... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part No R431005986 (formerly P -062018-00001) Logic Valves Miniature Shuttle ............................................. 12-14 Part No R431005928 (formerly P -061971-00000) Logic Flow Control Valves .................................................... 15-17 Part No R431005931 (formerly P -061975-00002) Logic Timer ........................................................................... 18-19 (Time In) Part No. R431006335 (formerly P -064003-00000) (Timed Release) R431006336 (formerly P -064003-00001) Multifunction Adjustable Logic Valve .................................... 20-22 Logic Solenoid Valve ............................................................ 23-24 Logic Test Assembly and Disassembly Schematic ....................................................... 25

SM-1200.9200

WARNING - INSTALLATION AND MOUNTING The user of these devices must conform to all

applicable electrical, mechanical, piping and other codes in the installation, operation or repair of these devices. Installation! Do not attempt to install, operate or repair these devices without proper training in the technique of working on pneumatic systems and devices, or under trained supervision. Compressed air systems contain high levels of stored energy. Do not attempt to connect, disconnect or repair these products when a system is under pressure. Always exhaust the pressure from an air system before performing any service work. Failure to do so can result in serious personal injury. Mounting! Devices should be mounted and positioned in such a manner that they cannot be accidentally operated.

Page 2: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

Description New Part No Previous Part No Working Pressure Adjustable Pressure Setting

Flow Rating @ 150

psi

Operating Temp.

Shift Defer- ential

Trip Pressure

Volume Capcty

Operatng Power / Power

Consump

MULTIFUNCTION LOGIC VALVE (Fig 1-1)

LOGIC VALVE MF L/SUBPLATE 3WAY OPN CTR

R431005976 p -062016-00000 150 psi maximum (10.3 bar) —- SCFM =

21.0 -20°F (-29°C) to +165°F (73.9°C) —-

NC 15 psi (1.0 bar)/30 psi (2.0 bar)

—- —-

LOGIC VALVE MF L/SUBPLATE 3WAY OPN CTR

R431005977 p -062016-00001 150 psi maximum (10.3 bar) —- SCFM =

21.0 -20°F (-29°C) to +165°F (73.9°C) —-

NC 15 psi (1.0 bar)/30 psi (2.0 bar)

—- —-

LOGIC PRESSURE REGULATOR (Fig 1-2)

LOGIC VALVE REDUCING L/SUBPLATE

R431005985 p -062018-00000 150 psi maximum (10.3 bar)

0 to 75 psi (0-5.2 bar) 0 to 140 psi (0-9.6 bar)

SCFM = 21.0

-20°F (-29°C) to +165°F (73.9°C) —- —- —- —-

LOGIC VALVE REDUCING L/SUBPLATE

R431005986 p -062018-00001 150 psi maximum (10.3 bar)

0 to 75 psi (0 - 5.2 bar) 0 to 140 psi (0 - 9.6 bar)

SCFM = 21.0

-20°F (-29°C) to +165°F (73.9°C) —- —- —- —-

MULTIFUNCTION LOGIC VALVE - HYDRAULIC (Fig 1-3)

LOGIC VALVE HMF L/SUBPLATE 3WAY OPN CTR

R431005967 p -062014-00000 Pneumatic 150 psi max (10.3 bar) / Hydraulic (Pilot) 350

—- SCFM = 21.0 Pneumat

-20°F (-29°C) to +165°F (73.9°C) —-

NC 110 psi (7.6 bar)/35 psi (2.4 bar)

—- —-

LOGIC VALVE HMF L/SUBPLATE 3WAY OPN CTR

R431005968 p -062014-00001 Pneumatic 150 psi max (10.3 bar) / Hydraulic (Pilot) 350

—- SCFM = 21.0 Pneumat

-20°F (-29°C) to +165°F (73.9°C) —-

NC 110 psi (7.6 bar)/35 psi (2.4 bar)

—- —-

LOGIC SHUTTLE VALVE (Fig 1-4)

LOGIC VALVE MINIATURE SHUTTLE

R431005928 p -061971-00000 150 psi maximum (10.3 bar) —- SCFM =

21.0 -20°F (-29°C) to +165°F (73.9°C)

1 0 psi max. (0.068

—- —- —-

LOGIC TIMER FLOW CONTROL VALVE (Fig 1-6)

LOGIC FLOW CONT VALVE W/TIMING VOL FREE

R431006335 p -064003-00000 150 psi maximum (10.3 bar) —- SCFM =

21.0 -25°F (-32°C) to +165°F (73.9°C) —- —-

2.2 cu. In. (36 cu. Cms.)

—-

LOGIC FLOW CONT VALVE W/TIME OUT L/SUBPL

R431006336 p -064003-00001 150 psi maximum (10.3 bar) —- SCFM =

21.0 -25°F (-32°C) to +165°F (73.9°C) —- —-

2.2 cu. In. (36 cu. Cms.)

—-

ADJUSTABLE MULTIFUNCTION LOGIC VALVE (Fig 1-7)

LOGIC VALVE MF L/SUBPLATE 3WAY 5- R431005932 p -061976-00000 150 psi maximum

(10.3 bar) -5 to 40 psi / 40 to 80 psi

SCFM = 21.0

-20°F (-29°C) to +165°F (73.9°C) —- —- —- —-

LOGIC VALVE MF L/SUBPLATE 3WAY 40 R431005933 p -061976-00001 150 psi maximum

(10.3 bar) -5 to 40 psi / 40 to 80 psi

SCFM = 21.0

-20°F (-29°C) to +165°F (73.9°C) —- —- —- —-

LOGIC SOLENOID VALVE (Fig 1-8A)

LOGIC VALVE SOL W/MAN OVER R431006752 p -065993-00000 150 psi maximum

(10.3 bar) —- SCFM = 6.0

-40°F (-40°C) to +165°F (73.9°C) —- —- —-

(28 Volts DC) / (7 watts AC)

LOGIC FLOW CONTROL VALVE (Fig 1-5A)

Time Release

Time-In

R431006335 P -064003-00000 150 psi maximum (10.3 bar) SCFM =

21.0 -25°F (-32°C) to +165°F (73.9°C)

2.2 cu. In. (36 cu. Cms.)

R431006336 P -064003-00001 150 psi maximum (10.3 bar) SCFM =

21.0 -25°F (-32°C) to +165°F (73.9°C)

2.2 cu. In. (36 cu. Cms.)

Page 3: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

Page 3

MULTIFUNTION LOGIC VALVE Refer to figure 1-1 & 1-1A for parts identification and proceed as follows: shut-off and vent air supply to control valve. Note: Replace worn parts from repair kit, part number R431006223, upon disassembly and inspection. DISASSEMBLY A. Remove two mounting screws (18) to remove

multifunction logic valve (figure 1-1) from plate assembly and align the valve on two (2) mounting bolts as shown on attached disassembly fixture schematic. Hold valve middle body section while disassembling. Remove two body screws (15) from the body (1, figure 1-1).

B. Remove diaphragm (11), spring seat (12), regulating spring (14) and spring shims (17) from cover (13).

C. Remove body gasket (6). D. Remove exhaust valve seat (9) and exhaust

valve spring (3) from valve seat body (7). E. Remove supply valve spring (4) and supply

valve (5). F. Remove packings (2 and 3) and packing (16)

from body (1). CLEANING. Clean all metal parts with a nonflammable solvent (barsol or mineral spirits). Wash all rubber parts with soap (Ivory-soft flakes) and water. Rinse thoroughly and dry parts with clean, dry, compressed air. INSPECTION AND REPAIR. Inspect and lubricate all O-Ring seals with Dow Corning No. 55 pneumatic grease. Repairs to this valve generally consist of replacement of any part found to be defective during the disassembly procedure.

REASSEMBLY AND INSTALLATION. After inspection and parts replacement, reassemble and install the multifunction logic valve as follows: A. Install packing (16) and packings (2 and 3) in

body (1). B. Install supply valve (5) and supply valve spring

(4). C. Install body gasket (6) to the valve seat body

(1). D. Install packing (10), to exhaust valve seat (9)

and exhaust valve spring (8), in the valve seat body (7).

E. Install diaphragm (11), spring seat (12), shims (17) regulation spring (14), and cover (13).

F. Install two body screws (15) in the body (1). TESTING. Attach the Logic Valve to a subplate assembly as shown on attached schematic. Apply a constant 100 psi air supply to port number 1 and check for leakage around valve body gaskets. No pressure should be shown on the delivery gauge at port 5. Apply graduated control pilot signal as per valve spring rating and note that pressure is shown on delivery gage at specified trip point of actuation. Check valve body and port 4 for any leakage. None permitted. Secure air supply and remove valve from test plate. Secure valve with mounting screws (18) to Logic Panel.

CORRECTIVE MAINTENANCE

MULTIFUNCTION LOGIC VALVE

Page 4: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

PORT - 1 Supply (normally closed)

PORT - 2 Control #1

PORT - 3 Supply (normally open)

PORT - 4 Control #2

PORT - 5 Delivery

PORT IDENTITY SCHEDULE

Page 4

MULTIFUNCTION LOGIC VALVE

Fig 1-1

Page 5: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

Page 5

MULTIFUNCTION LOGIC VALVE

Assembly View

Qty Description Previous Part Number

1 1 Body P -067247-00000

* 2 1 O-ring, 7/32” x 11/32” See Kit

* 3 1 O-ring, 3/8” x 1/2” See Kit

4 1 Spring, Supply Valve P63075-00000

* 5 1 Valve, Supply See Kit

* 6 1 Gasket, Body See Kit

7 1 Body, Valve Seat P67249-00000

8 1 Spring, Exhaust Valve P52889-00000

9 1 Seat, Exhaust Valve P61986-00001

* 10 1 O-ring, 1/8” x 1/4” See Kit

* 11 1 Diaphragm See Kit

12 1 Seat, Spring P61987-00000

13 1 Cover P67156-00000

14 1 Spring, Regulating (15 psi) P62012-00000

14A 1 Spring, Regulating (30 psi) P62013-00000

14B 1 Spring, Regulating (80 psi) P60360-00000

15 2 Screw. 8-32 x 2-14” (not shown) P49109-00003

* 16 5 O-ring, 3/8” OD See Kit

Ref New Part Number

R431007038

See Kit

See Kit

R431006176

See Kit

See Kit

R431007106

R431003030

R431005945

See Kit

See Kit

R431005946

R431007028

R431005964

R431005965

R431005489

R431001693

See Kit

—- —- Complete MF L/Subplate 3way open ctr R431005976 P -062016-00000

—- —- Complete MF L/Subplate 3way open ctr R431005977 P -062016-00001

—- —- Complete MF L/Subplate 3way open ctr R431005980 P -062016-00004

* Recommended spare parts to be retained in stock at all times. Available in Repair it form, order part number R431006223 (formerly P -063392-00000).

Fig 1-1A

Page 6: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

Page 6

CORRECTIVE MAINTENANCE

LOGIC PRESSURE REGULATOR

LOGIC PRESSURE REGULATOR Refer to figure 1-2 & 1-2A for parts identification and proceed as follows: shut-off and vent air supply to control valve. Note: Replace worn parts from repair kit, part number P -063966-00000, upon disassembly and inspection. DISASSEMBLY A. Remove packing (20) from body (1). Remove

the two mounting screws (21) to remove valve (figure 1-2) and align the valve on disassembly fixture as shown on schematic. Hold valve middle body section while disassembling. Turn adjusting screw cap (18) counterclockwise until cap is removed. Remove two body screws (19) from the spring housing (13).

B. Remove spring seat (12), regulating spring (15), ball seat (16), ball (17), adjustment screw (18), and packing (14) from spring housing (13).

C. Remove diaphragm (11), spring (8), exhaust valve seat (9), and packing (10) from valve seat body (7).

D. Remove gasket (6) from body (1). E. Remove supply valve spring (4), supply valve

(5) and packings (2 and 3) from body (1). CLEANING. Clean all metal parts with a nonflammable solvent (barsol or mineral spirits). Wash all rubber parts with soap (Ivory-soft flakes) and water. Rinse thoroughly and dry parts with clean, dry, compressed air. INSPECTION AND REPAIR. Inspect and lubricate all O-Ring seals with Dow Corning No. 55 pneumatic grease except diaphragm and gasket. Repairs to this valve generally consist of

replacement of any part found to be defective during the disassembly procedure. REASSEMBLY AND INSTALLATION. After inspection and parts replacement, reassemble and install the logic pressure regulator as follows: A. Install packings (2 and 3), supply valve (5),

supply valve spring (4), and gasket (6) into body (1). Align body (7) with body (1) by ball plugs on side of bodies.

B. Install packing (10) to exhaust valve seat (9), spring (8), and diaphragm (11) into the valve seat body (7) while holding the two bodies together.

C. Install packing (14), adjustment screw (18), ball (17), ball seat (19), regulating spring (15), spring seat (12) and spring housing (13).

D. Install two body screws (19). Secure spring housing (13) to body (1).

E. Install packing (20) into body (1). TESTING. Attach the Logic Valve to a subplate as shown on attached schematic. Apply a constant 150 psi air supply to port number 3 and check for leakage around valve body gaskets. No pressure should be shown on the delivery gauge at valve port 5. Adjust slotted cap screw clockwise until 40 psi is showing. Check valve body and port 4 for any leakage. None permitted. Reduce pressure to original pressure setting. Secure air supply and remove valve from test plate and reconnect to Logic Panel with mounting screws (21).

Page 7: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

Page 7

PORT - 1 Supply (normally closed)

PORT - 2 Control #1

PORT - 3 Supply (normally open)

PORT - 4 Control #2

PORT - 5 Delivery

PORT IDENTITY SCHEDULE

LOGIC PRESSURE REGULATOR

Fig 1-2

Page 8: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

Page 8

LOGIC PRESSURE REGULATOR

Qty Description Previous Part Number

1 1 Body P -067247-00000

* 2 1 O-ring, 7/32” x 11/32” See Kit

* 3 1 O-ring, 3/8” x 1/2” See Kit

4 1 Spring, Supply Valve P -063075-00000

* 5 1 Valve, Supply See Kit

* 6 1 Gasket, Body See Kit

7 1 Body, Valve Seat P -067249-00000

8 1 Spring, Exhaust Valve P -052889-00000

9 1 Seat, Exhaust Valve P -061986-00001

* 10 1 O-ring, 1/8” x 1/4” See Kit

* 11 1 Diaphragm See Kit 12 1 Seat, Spring P -061987-00000

13 1 Housing, Spring P -061992-00000

* 14 1 O-ring, 1-1/8” OD See Kit

15 1 Spring, Regulating (0-75 psi) P -060360-00000

15 1 Spring, Regulating (0-140 psi) P -062549-00000

16 1 Seat, Ball & Spring P -061988-00000

17 1 Ball, 3/8” Dia. P -049680-00004

Ref

18 1 Screw, Adjusting P -061993-00000

19 2 Screw (Not shown) P -049109-00003

* 20 5 O-ring, 3/8” OD See Kit

21 2 Screw P -049467-00017

New Part Number

R431007038

See Kit

See Kit

R431006176

See Kit

See Kit

R431007041

R431003030

R431005945

See Kit

See Kit R431005946

R431005948

See Kit

R431005489

R431006081

R431005947

R431001960

R431005949

R431001693

See Kit

R431001776

Complete Pressure Regulator (0-75 psi) R431005985 P -062018-00000

Complete Pressure Regulator (0-140 psi) R431005986 P -062018-00001

* Recommended spare parts to be retained in stock at all times. Available in Repair kit form, order part number R431006319 (formerly P -063966-00000).

Valve Function Symbol

Fig 1-2A

Page 9: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

Page 9

MULTIFUNTION LOGIC VALVE Refer to figure 1-3 & 1-3A for parts identification and proceed as follows: shut-off and vent air supply to control valve and hydraulic pilot pressure. Note: Replace worn parts from repair kit, part number R431006320, upon disassembly and inspection. DISASSEMBLY A. Remove two mounting screws (22) to remove

multifunction logic valve (figure 1-3) from plate assembly and align the valve on two (2) mounting bolts as shown on attached disassembly fixture schematic. Hold valve middle body section while disassembling. Remove two body screws (17) from the body (1, figure 1-3).

B. Remove cover (14). Remove regulating spring (15) and spring shims (16).

C. Remove piston seal (12). D. Remove exhaust valve seat (9) and exhaust

valve spring (3) from valve seat body (7). Remove packing (10). Disassemble piston (11) by removing nut (20) and washer (19). Remove packing (21).

E. Remove packing (6A) from body (7) and gasket (6) from body (1). Remove supply valve spring (4) and supply valve (5).

F. Remove packings (2 and 3) and packing (16) from body (1).

CLEANING. Clean all metal parts with a nonflammable solvent (barsol or mineral spirits). Wash all rubber parts with soap (Ivory-soft flakes) and water. Rinse thoroughly and dry parts with clean, dry, compressed air. INSPECTION AND REPAIR. Inspect and lubricate all O-Ring seals with Dow Corning No. 55 pneumatic grease. Repairs to this valve generally consist of replacement of any part found to be defective during the disassembly procedure. REASSEMBLY AND INSTALLATION. After inspection and parts replacement, reassemble and install the multifunction logic valve as follows:

A. Install packing (18) and packings (2 and 3) in body (1).

B. Install supply valve (5) and supply valve spring (4).

C. Install body gasket (6) to the valve seat body (1) and packing (6A).

D. Install packing (10), to exhaust valve seat (9) and exhaust valve spring (8), in the valve seat body (7).

E. Reconnect exhaust seat (9) to piston (11) with nut (20) and washer (19). Attach piston seal (12) to piston (11). NOTE: Align body (1) to body (7) by ball plugs on side of bodies and hold together.

F. Install regulation spring (15), shims (16), and cover (14). NOTE: Align cover (14) pilot port and diaphragm port hole to right side of ball plugs in body (7).

G. Install two body screws (15) in the body (1). TESTING. Attach the Logic Valve to a subplate assembly as shown on attached schematic. Apply a constant 100 psi air supply to port number 1 and check for leakage around valve body gaskets. No pressure should be shown on the delivery gauge at port 5. Apply graduated control pilot signal as per valve spring rating and note that pressure is shown on delivery gage at specified trip point of actuation. Check valve body and port 4 for any leakage. None permitted. Secure air supply and remove valve from test plate. Secure valve with mounting screws (22) to Logic Panel.

CORRECTIVE MAINTENANCE

MULTIFUNCTION LOGIC VALVE / HYDRAULIC

Page 10: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

Page 10

PORT - 1 Supply (normally closed)

PORT - 2 Control #1

PORT - 3 Supply (normally open)

PORT - 4 Control #2

PORT - 5 Delivery

PORT IDENTITY SCHEDULE

MULTIFUNCTION LOGIC VAVLE / HYDRAULIC

Fig. 1-3

Page 11: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

Page 11

MULTIFUNCTION LOGIC VALVE / HYDRAULIC CONTROL SIGNAL

Qty Description Previous Part Number

1 1 Body P -067247-00000

* 2 2 O-ring, 7/32” x 11/32” See Kit

* 3 1 O-ring, 3/8” x 1/2” See Kit

4 1 Spring, Supply Valve P -063075-00000

* 5 1 Valve, Supply See Kit

* 6 1 Gasket, Body See Kit

7 1 Body, Valve Seat P -064693-00000

8 1 Spring, Exhaust Valve P -060836-00000

9 1 Seat, Exhaust Valve P -064692-00001

* 10 1 O-ring, 1/8” x 1/4” See Kit

11 1 Piston P -062005-00000

* 12 1 U-cup Seal See Kit

* 13 1 Gasket, Cover See Kit

14 1 Cover P -063077-00000

15 1 Spring, Regulating (35 psi) P -062013-00000

15A 1 Spring, Regulating (110 psi) P -062448-00000

15B 1 Spring, Regulating (220 psi) P -062549-00000

17 2 Screws, 8/32” x 2-1/4” (Not shown) P -049109-00003

Ref

* 18 5 O-ring, 3/8” OD See Kit

19 1 Washer, Lock No 10 P -049866-00007

20 1 Nut, 10-32 P -049901-00016

* 21 1 O-ring See Kit

* 6A 1 O-ring, 7/32” x 11/32” See Kit

≠ 16 3 Shims, (Not shown) P -053455-00003

22 2 Screw P -049467-00017

New Part Number

R431007038

See Kit

See Kit

R431006176

See Kit

See Kit

See Kit

R431006470

R431005588

R431006469

See Kit

R431005958

See Kit

See Kit

R431007028

R431005965

R431006056

R431006081

R431003217

R431001693

See Kit

R431002344

R432002246

See Kit

R431001776

—- —- Multifunction Logic Valve (35 psi) complete R431005968 P -062014-00001

—- —- Multifunction Logic Valve (110 psi) complete R431005967 P -062014-00000

—- —- Multifunction Logic Valve (220 psi) complete R431005969 P -062014-00003

* Recommended spare parts to be retained in stock at all times. * Available in Repair kit form, order part number R431006320 (formerly P -063967-00000). ≠ Maximum quantity required. Actual quantity installed at factory depends on spring ratings.

Fig. 1-3A

Valve Function Symbol

Page 12: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

Page 12

CORRECTIVE MAINTENANCE

LOGIC SHUTTLE VALVE Refer to figure 1-4 & 1-4A for parts identification. Shut-off and vent air supply to control valve and proceed as follows: Note: Replace worn parts from repair kit, part number R431006240, upon disassembly. DISASSEMBLY A. Remove two mounting screws (7) from (figure

1-4) and align valve on disassembly fixture as shown on schematic. Remove two screws (5) from body (1) and cover (4).

B. Remove gasket (3), diaphragm (2), and packing (6).

CLEANING. Clean all metal parts with a nonflammable solvent (barsol or mineral spirits). Wash all rubber parts with soap (Ivory-soft flakes) and water. Rinse thoroughly and dry parts with clean, dry, compressed air. INSPECTION AND REPAIR. Inspect and lubricate all O-Ring seals with Dow Corning No. 55 pneumatic grease except diaphragm and gasket. Repairs generally consist of replacement of any part found to be defective during the disassembly procedure.

REASSEMBLY AND INSTALLATION. After inspection, install replacement parts and reassemble the logic shuttle valve as follows: A. Install packing (6), diaphragm (2), and gasket

(3). B. Install cover (4) and body (1) with two screws

(5). TESTING. Attach the Logic Valve to a subplate assembly as shown on attached schematic. Apply a constant 100 psi air supply to port number 1 and note that delivery gauge in port 5 shows 100 psi. Check for leakage at port 3. None permitted. Vent supply. Apply 100 psi to port 3 and note that delivery shows 100 psi. Check for leakage at port 1. None permitted. Vent supply and remove valve. Reattach logic valve with mounting screws (7).

LOGIC SHUTTLE VALVE

Page 13: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

Page 13

LOGIC SHUTTLE VALVE

PORT IDENTITY SCHEDULE

PORT - 1 or 3 Inlet Pressure

PORT - 5 Delivery Pressure

Fig. 1-4

Page 14: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

Page 14

LOGIC SHUTTLE VALVE

Ref Qty Description New Part Number Previous Part Number

— —- Complete Multifunction Logic Valve (35 psi) R431005928 P -061971-00000

1 1 Body R431005938 P -061979-00001

* 2 1 Diaphragm See Kit See Kit

* 3 1 Gasket See Kit See Kit

4 1 Cover R431005940 P -061980-00001

5 2 Screw, 8-32 x 3/4” R431001690 P -049109-00000

* 6 3 O-ring, 3/8” O.D. See Kit See Kit

7 2 Screw R431001772 P -049467-00013

* Recommended spare parts to be retained in stock at all times. * Available in Repair kit form, order part number R431006240 (formerly P -063400-00000).

Fig. 1-4A

VALVE FUNCTION SYMBOL

Page 15: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

Page 15

LOGIC FLOW CONTROL VALVE

CORRECTIVE MAINTENANCE

LOGIC FLOW CONTROL VALVE Refer to figure 1-5A for parts identification. Shut-off and vent air supply to control valve and proceed as follows: Note: Replace worn parts from repair kit, part number R431006224. DISASSEMBLY A. Remove two mounting screws (21) to remove

valve from Logic Plate. B. Remove two screws (1), lock washers (2) from

logic flow control valve (16) and base (4). C. Remove packings (3 and 5) and filter (6) from

housing (16). D. Remove cap (7) and packing (8). E. Turn nut (14) clockwise until flush with body

(16). F. Remove guide (9) and packings (10, 11). CLEANING. Clean all metal parts with a nonflammable solvent (barsol or mineral spirits). Wash all rubber parts with soap (Ivory-soft flakes) and water. Rinse thoroughly and dry parts with clean, dry, compressed air. INSPECTION AND REPAIR. Inspect and lubricate all O-Ring seals with Dow Corning No. 55 pneumatic grease. Repairs generally consist of replacement of any part found to be defective during the disassembly procedure.

REASSEMBLY AND INSTALLATION. After inspection, install replacement parts and reassemble the logic flow control valve as follows: A. Install packing (10. 11), and guide (9). B. Rotate nut (14) counterclockwise until fully out. C. Install packing (8) and cap (7). D. Install filter (6) and packings (3 and 5). E. Install base (4) to flow control valve housing

(16). Secure with lock washers (21) and two screws (1).

F. Install packings (3). G. Install two screws. Secure figure 1-4A in place

on the Logic Panel. TESTING. Attach the Logic Valve to a sub-plate as shown on page 25. Connect supply pressure to port 1 and put a gauge in port 5 and port 3. Turn on the supply pressure to 100 psi. Read the pressure on gauge 5 should read the same as the supply pressure and gauge 3 should read zero. Back the pressure to zero and reverse lines 1 and 3. Increase pressure to 100 psi and gauge 5 should read 100 psi and gauge 1 should read zero. Back the pressure to zero and disconnect the lines.

Page 16: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

Page 16

LOGIC FLOW CONTROL VALVE

Fig. 1-5A

VALVE FUNCTION SYMBOL

PORT IDENTITY SCHEDULE

PORT - 3-4 Controlled Flow

PORT - 4-3 Free Flow

Ref Qty Description New Part Number Previous Part Number

— —- Complete Logic Flow Control Valve R431005931 P -061975-00002

1 2 Screw, 8-32 x 1-3/4” R431001692 P -049109-00002

2 2 Lockwasher R432012235 P -049866-00003

* 3 2 O-ring, 3/8” O.D. See Kit See Kit

4 1 Base R431005956 P -062000-00001

* 5 2 O-ring, 9/16” O.D. See Kit See Kit

6 1 Filter R431005954 P -061999-00000

7 1 Cap R431005953 P -061998-00000

* 8 1 O-ring, 3/4” O.D. See Kit See Kit

9 1 Guide R431005952 P -061997-00000

* 10 1 U cup See Kit See Kit

* 11 1 O-ring, 5/16” O.D. See Kit See Kit

12 1 Screw, regulating R431005951 P -061996-00000

* 13 1 O-ring, 1/4” O.D. See Kit See Kit

14 1 Nut, Knurled R431006292 P -063497-00000

15 1 Jam Nut, 10-48 Hex. R431002426 P -049901-00036

16 1 Housing R431005950 P -061995-00000

* Recommended spare parts to be retained in stock at all times. * Available in Repair kit form, order part number R431006224 (formerly P -063393-00000).

Page 17: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

Page 17

LOGIC TIMER FLOW CONTROL VALVE

CORRECTIVE MAINTENANCE

LOGIC TIMER FLOW CONTROL VALVE Refer to figure 1-6 & 1-6A for parts identification. Shut-off and vent air supply to control valve and proceed as follows: Note: Replace worn parts from repair kit, part number R431006224 (formerly P -063393-00000). DISASSEMBLY A. Remove two mounting screws (21) to remove

valve from Logic Plate. B. Remove packings (19 and 20) from volume (1). C. Remove two screws (1), lockwashers (2) from

logic flow control valve (16) and base (4). D. Remove packings (3 and 5) and filter (6) from

housing (16). E. Remove cap (7) and packing (8). F. Turn nut (14) clockwise until flush with body

(16). G. Remove guide (9) and packings (10 and 11). CLEANING. Clean all metal parts with a nonflammable solvent (barsol or mineral spirits). Wash all rubber parts with soap (Ivory-soft flakes) and water. Rinse thoroughly and dry parts with clean, dry, compressed air. INSPECTION AND REPAIR. Inspect and lubricate all O-Ring seals with Dow Corning No. 55 pneumatic grease. Repairs generally consist of replacement of any part found to be defective during the disassembly procedure. REASSEMBLY AND INSTALLATION. After inspection, install replacement parts and

reassemble the logic timer flow control valve as follows: A. Install packing (10 and 11), and guide (9). B. Rotate nut (14) counterclockwise until fully out. C. Install packing (8) and cap (7). D. Install filter (6) and packings (3 and 5). E. Install base (4) to flow control valve housing

(16). Secure with lockwashers (21) and two screws (1).

F. Install packings (19 and 20) in volume (18). G. Install two screws (21) to the time in volume

(18). Secure figure 1-5A in place on the Logic Panel.

TESTING. Attach the Logic Valve to a sub-plate as shown on page 25. Connect supply to port 3 and gauge to port 4. Make sure adjusting screw # 14 is all the way in before turning on the air supply. Set the air supply to 100 psi and slowly turn adjusting out and the pressure on port 4 should start to slowly go up as you turn the screw out till it reaches 100 psi. Then back the pressure off and connect supply to port 4 and gauge in port 3 and turn adjusting screw all the way back in. Turn on the air supply to 100 psi and the gauge in port 3 should go to 100 psi. Release the pressure before removing the valve.

Page 18: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

Page 18

LOGIC TIMER FLOW CONTROL VALVE

PORT IDENTITY SCHEDULE

PORT - 3-4 Timed Application

PORT - 4-3 Timed Release

Not normally disassembled during overhaul

Fig.1-6

Page 19: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

Page 19

LOGIC TIMER FLOW CONTROL VALVE

Ref Qty Description New Part Number Previous Part Number

— —- Complete Logic Timer Unit (Time-in) R431006335 P -064003-00000

— —- Complete Logic Timer Unit (Time-out) R431006336 P -064003-00001

17 1 Logic Flow Control Valve (see parts list pg 16) R431005931 P -061975-00002

18 1 Volume-Time in (for P -064003-00000) R431006228 P -063395-00004

18 1 Volume-Time out (for P -064003-00001) R431006227 P -063395-00003

* 19 2 O-ring, 3/8” O.D. See Kit See Kit

* 20 1 O-ring, 1” O.D. See Kit See Kit

21 2 Mounting Screw, No. 8-32 x 5 1/2” LG R431001775 P -049467-00016

* Available in Repair kit form, order part number R431006224 (formerly P -063393-00000).

Fig.1-6A

Timed Release

Timed-in Application

Page 20: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

Page 20

MULTIFUNCTION ADJUSTABLE LOGIC VALVE

CORRECTIVE MAINTENANCE

LOGIC TIMER FLOW CONTROL VALVE Refer to figure 1-7 & 1-7A for parts identification. Shut-off and vent air supply to control valve and proceed as follows: Note: Replace worn parts from repair kit, part number R431006380 upon disassembly and inspection. DISASSEMBLY A. Remove the two mounting screws (26) to

remove valve (figure 1-7) and align the valve on disassembly fixture as shown on schematic. Hold valve middle body section while disassembling. Turn adjusting screw cap (22) counterclockwise until cap is removed. Remove two body screws (23) from the spring housing (17). Remove packing (20) from body (1).

B. Remove spring seat (16), regulating spring (19), ball seat (20), ball (21), and packing (18) from spring housing (17).

C. Remove diaphragm (15), diaphragm follower (14), packing (10), from spacer (13) and diaphragm follower (12).

D. Remove diaphragm (11), spring (8), exhaust valve seat (9), and packing (10) from valve seat body (7).

E. Remove supply valve spring (4), supply valve (5), and packings (2 and 3) from body (1) and gasket (6).

CLEANING. Clean all metal parts with a nonflammable solvent (barsol or mineral spirits). Wash all rubber parts with soap (Ivory-soft flakes) and water. Rinse thoroughly and dry parts with clean, dry, compressed air. INSPECTION AND REPAIR. Inspect and lubricate all O-Ring seals with Dow Corning No. 55 pneumatic grease except diaphragm and gasket. Repairs generally consist of replacement of any part found to be defective during the disassembly procedure. REASSEMBLY AND INSTALLATION. After inspection, install replacement parts and reassemble the logic pressure regulator as follows:

A. Install packings (2 and 3), supply valve (5), supply valve spring (4), and gasket (6) into body (1). Align body (7) with body (1) by ball plugs on side of bodies.

B. Install packing (10) to exhaust valve seat (9) and diaphragm follower (14). Install valve seat (9) spring (8), and diaphragm (11) into the valve seat body (7) while holding the two bodies together. And diaphragm follower (12) and spacer (13).

C. Install diaphragm follower (14) to spacer (13), diaphragm (15).

D. Install adjustment screw (22), ball (21), ball seat (20), regulating spring (19A/19B), and spring seat (16) and spring housing (17). NOTE: Align housings and diaphragms port hole to the right side of ball plugs in bodies as shown in exploded view.

E. Install two body screws (23). Secure spring housing (17) to body (1).

F. Install packing (20) in body (1). TESTING. Attach the logic valve to a subplate as shown on attached schematic. Apply a constant 150 psi air supply to port number 3 and check for leakage around valve body gaskets. No pressure should be showing on delivery gauge at valve port no. 5. Adjust slotted cap screw clockwise until 40 psi is showing. Check valve body and port no. 4 for any leakage. None permitted. Reduce pressure to original pressure setting. Secure air supply and remove valve from test plate and reconnect to Logic Panel with mounting screws (26).

Page 21: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

Page 21

Fig 1-7

MULTIFUNCTION ADJUSTABLE LOGIC VALVE

Page 22: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

Page 22

MULTIFUNCTION ADJUSTABLE LOGIC VALVE

Ref Qty Description New Part Number Previous Part No.

—- —- Mltfnctn Adj. Logic Vlv 5-40 psi (less plate), Complete R431005932 P -061976-00000 —- —- Mltfnctn Adj. Logic Vlv 40-80psi (less plate), Complete R431005933 P -061976-00001

1 1 Body, Cp. R431007038 P -067247-00000 * 2 1 O-ring See Kit See Kit * 3 1 O-ring, 3/8” X 1/2” See Kit See Kit 4 1 Supply, Valve spring R431006176 P -063075-00000 * 5 1 Supply, Valve See Kit See Kit * 6 1 Valve, Body gasket See Kit See Kit * 7 1 Valve, Seat body See Kit See Kit 8 1 Exhaust, Valve spring R431005588 P -060836-00000 9 1 Exhaust, Valve seat R431006470 P -064693-00001 * 10 2 O-ring, 1/8” X 1/4” See Kit See Kit * 11 1 Diaphragm See Kit See Kit 12 1 Diaphragm, Follower R431005957 P -062002-00000 13 1 Diaphragm, Spacer R431005943 P -061984-00000 14 1 Diaphragm, #2 Followers R431005944 P -061985-00000 * 15 1 Diaphragm See Kit See Kit

—- —- Mltfnctn Adj. Logic Vlv 80-120psi (less plate),Complete R431005934 P -061976-00002

—- —- Multifunction Adj. Logic Vlv (w/subplate), Complete —- P -061978-00001 —- —- Multifunction Adj. Logic Vlv (w/subplate), Complete —- P -061978-00000

16 1 Spring, Seat R431005946 P -061987-00000 17 1 Spring, Housing R431005948 P -061992-00000 * 18 1 O-ring, 1 1/8” O.D. See Kit See Kit 19A 1 Compression Spring 5 to 40 psi R431005489 P -060360-00000 19B 1 Compression Spring 40 to 80 psi R431002993 P -052738-00000

20 1 Ball & Spring seat R431005947 P -061988-00000 21 1 Steel Ball, 3/8” Diameter R431001962 P -049680-00010 22 1 Adjusting screw R431005949 P -061993-00000 23 2 Pan-head Screw, 8-32 x 2 3/4” (not shown) R431001694 P -049104-00004 * 24 5 O-ring, 3/8” O.D. See Kit See Kit 25 1 Subplate R431006017 P -062129-00001 26 2 Screw, 8-32 x 4 (not shown) R431001769 P -049467-00010

19C 1 Compression Spring 80 to 120 psi R431006081 P -062549-00000

* Recommended spare parts to be retained in stock at all times. * Available in Repair kit form, order part number R431006380 (formerly P -064201-00000).

Fig. 1-7A

Page 23: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

Page 23

LOGIC SOLENOID VALVE

CORRECTIVE MAINTENANCE

LOGIC SOLENOID VALVE Refer to figure 1-8A for parts identification. Secure supply pressure and proceed as follows: Note: Replace worn parts from repair kit, part number P -066222-00000. DISASSEMBLY A. Disconnect electrical leads from solenoid valve

(3) to terminal block. B. Remove two mounting screws (16) from body

assembly (15). C. Disconnect connector (2) from solenoid valve

(3). Pull tubing (1) from body assembly (15). D. Remove solenoid valve (3) from the body

assembly (15). Remove solenoid gasket seal, plunger and plunger housing. Replace if necessary with solenoid valve (3).

CLEANING. Clean all metal parts with a nonflammable solvent (barsol or mineral spirits). Wash all rubber parts with soap (Ivory-soft flakes) and water. Rinse thoroughly and dry parts with clean, dry, compressed air. INSPECTION AND REPAIR. Inspect and lubricate all O-Ring seals with Dow Corning No. 55 pneumatic grease. Repairs generally consist of

replacement of any part found to be defective during the disassembly procedure. REASSEMBLY AND INSTALLATION. After inspection, parts replacement, and reassembly, install the logic solenoid valve as follows: A. Install packing (12 and 13) in body assembly

(15). B. Install solenoid valve (3) to the body assembly

(15). C. Install tubing (1) into body assembly (15).

Connect the connector (2) to solenoid valve (3).

TESTING. Secure valve to a subplate - R431006017 as shown on attached schematic. Open supply to Port No. 1. No delivery a Port 5 gauge check leakage around tube No. 1. None permitted. Energize solenoid coil with 28 VDC power signal. Delivery gauge should show pressure. De-energize solenoid coil and secure supply and remove valve mounting screws.

Page 24: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

Page 24

LOGIC SOLENOID VALVE

Ref Qty Description New Part Number Previous Part

—- —- Logic Solenoid Valve, Complete R431006752 P -065993-00000 1 1 Tubing, Solenoid supplyu 1/4” O.D. —- —- 2 1 Fitting, female connector R431001689 P -049103-00002 * 3 1 Solenoid coil assembly C.P. R431006753 P -065994-00000 * 4 1 Washer In Item 3 —- * 5 1 Plunger In Item 3 —- * 6 1 Spring. plunger In Item 3 —- * 7 1 Post In Item 3 —- * 8 1 Solenoid coil In Item 3 —- * 9 1 Washer In Item 3 * 10 1 Washer In Item 3 —- 11 1 Fitting R432012165 P -049722-00017 * 12 1 Packing, O-ring See Kit —- * 13 1 Packing, O-ring See Kit —- 14 1 Nameplate R432011765 P -049182-00000 15 1 Base Block R431006756 P -065997-00000 16 2 Mounting pan-head screw R431001772 P -049467-00013

Fig 1-8A

* Recommended spare parts to be retained in stock at all times. * Available in Repair kit form, order part number P -066222-00000.

Page 25: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

Page 25

TEST PROCEDURE

Ref Qty Description New Part Number Previous Part No.

1A,B,C 3 Shut off valve R431006012 P -062098-00000 2 1 Regulator R431003624 P -055119-00000 3 1 Air gauge R432011829 P -048134-00000 4 1 Test plate R431006017 P -062129-00001 5 1 Air gauge R432011829 P -048134-00000 6 1 Quick disconnect unit N\A N\A

TEST PROCEDURE 1. Attach test valve to plate 2. Open supply - 1A & 1B 3. Preference attached procedure

per individual valve part number.

100 psi supply inlet

Reference attached individual valve test procedure per valve part number.

Mounting screw with slotted screw head removed.

Subplate part number R431006017

Screw part number R431001776

Page 26: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

Page 26

NOTES

Page 27: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

NOTICE TO PRODUCT USERS

1. WARNING: FLUID MEDIA AVENTICS pneumatic devices are designed and tested for use with filtered, clean, dry, chemical free air at pressures and temperatures within the specified limits of the device. For use with media other than air or for human life support systems, AVENTICS must be consulted. Hydraulic cylinders are de-signed for operation with filtered, clean, petroleum based hy-draulic fluid; operation using fire-resistant or other special types of fluids may require special packing and seals. Consult the factory. 2. WARNING: MATERIAL COMPATIBILITY Damage to product seals or other parts caused by the use of noncompatible lubricants, oil additives or synthetic lubricants in the air system compressor or line lubrication devices voids AVENTICS warranty and can result in product failure or other malfunction. See lubrication recommendations below. AIR LINE LUBRICANTS! In service higher than 18 cycles per minute or with continuous flow of air through the device, an air line lubricator is recommended.* (Do not use line lubrication with vacuum products.) However, the lubricator must be main-tained since the oil will wash out the grease, and lack of lubri-cation will greatly shorten the life expectancy. The oils used in the lubricator must be compatible with the elastomers in the device. The elastomers are normally BUNA-N, NEOPRENE, VITON, SILICONE and HYTREL. AVENTICS recommends the use of only petroleum based oils without synthetic addi-tives, and with an aniline point between 180° F and 210° F. COMPRESSOR LUBRICANTS! All compressors (with the exception of special "oil free" units) pass oil mist or vapor from the internal crankcase lubricating system through to the com-pressed air. Since even small amounts of non-compatible lubri-cants can cause severe seal deterioration (which could result in component and system failure) special care should be taken in selecting compatible compressor lubricants. 3. WARNING: INSTALLATION AND MOUNTING The user of these devices must conform to all applicable elec-trical, mechanical, piping and other codes in the installation, operation or repair of these devices.

INSTALLATION ! Do not attempt to install, operate or repair these devices without proper training in the technique of work-ing on pneumatic or hydraulic systems and devices, unless under trained supervision. Compressed air and hydraulic sys-tems contain high levels of stored energy. Do not attempt to connect, disconnect or repair these products when a system is under pressure. Always exhaust or drain the pressure from a system before performing any service work. Failure to do so can result in serious personal injury. MOUNTING! Devices should be mounted and positioned in such a manner that they cannot be accidentally operated. 4. WARNING: APPLICATION AND USE OF PRODUCTS The possibility does exist for any device or accessory to fail to operate properly through misuse, wear or malfunction. The user must consider these possibilities and should provide ap-propriate safe guards in the application or system design to prevent personal injury or property damage in the event of a malfunction. 5. WARNING: CONVERSION, MAINTENANCE AND REPAIR When a device is disassembled for conversion to a different configuration, maintenance or repair, the device must be tested for leakage and proper operation after being reassembled and prior to installation. MAINTENANCE AND REPAIR! Maintenance periods should be scheduled in accordance with frequency of use and working conditions. All AVENTICS products should provide a minimum of 1,000,000 cycles of maintenance free service when used and lubricated as recommended. However, these products should be visually inspected for defects and given an "in sys-tem" operating performance and leakage test once a year. Where devices require a major repair as a result of the one million cycles, one year, or routine inspection, the device must be disassembled, cleaned, inspected, parts replaced as re-quired, rebuilt and tested for leakage and proper operation prior to installation. See individual catalogs for specific cycle life estimates. 6. PRODUCT CHANGES Product changes including specifications, features, designs and availability are subject to change at any time without no-tice. For critical dimensions or specifications, contact factory. *Many AVENTICS pneumatic valves and cylinders can operate with or without air line lubrication; see individual sales catalogs for details.

LIMITATIONS OF WARRANTIES & REMEDIES AVENTICS warrants its products sold by it to be free from defects in material and workmanship to the following: For twelve months after shipment AVENTICS will repair or replace (F.O.B. our works), at its option, any equipment which under normal conditions of use and service proves to be defective in material or workmanship at no charge to the purchaser. No charge will be made for labor with respect to defects covered by this Warranty, provided that the work is done by AVENTICS or any of its authorized service facilities. However, this Warranty does not cover expenses incurred in the removal and reinstallation of any product, nor any downtime incurred, whether or not proved defective. All repairs and replacement parts provided under this Warranty policy will assume the identity, for warranty purposes, of the part re-placed, and the warranty on such replacement parts will expire when the warranty on the original part would have expired. Claims must be submitted within thirty days of the failure or be subject to rejection. This Warranty is not transferable beyond the first using purchaser. Specifically, excluded from this Warranty are failures caused by mis-use, neglect, abuse, improper operation or filtration, extreme temperatures, or unauthorized service or parts. This Warranty also ex-cludes the use of lubricants, fluids or air line additives that are not compatible with seals or diaphragms used in the products. This War-ranty sets out the purchaser's exclusive remedies with respect to products covered by it, whether for negligence or otherwise. Neither, AVENTICS nor any of its affiliates will be liable for consequential or incidental damages or other losses or expenses incurred by reason of the use or sale of such products. Our liability (except as to title) arising out of the sale, use or operation of any product or parts, wheth-er on warranty, contract or negligence (including claims for consequential or incidental damage) shall not in any event exceed the cost of replacing the defective products and, upon expiration of the warranted period as herein provided, all such liability is terminated. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, WHETHER FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE. No attempt to alter, amend or extend this Warranty shall be effective unless author-ized in writing by an officer of AVENTICS Corporation. AVENTICS reserves the right to discontinue manufacture of any product, or change product materials, design or specifications without notice.

Page 27

Page 28: LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE · 2018. 6. 12. · Logic Pressure Regulator ..... 6-8 0-75 psi (Part No R431005985 (formerly P -062018-00000) 0-140 psi (Part

AVENTICS Corporation 1953 Mercer Road Lexington, KY 40511 www.aventics.com/us [email protected] AVENTICS Incorporated 3426 Mainway Drive Burlington, Ontario CANADA L7M 1A8 www.aventics.com/ca [email protected]

SM-1200.9200/May 2014 Subject to change. Printed in United States. AVENTICS Corporation. This document, as well as the data, specifications, and other information set forth in it, are the exclusive property of AVENTICS. It may not be reproduced or given to third parties without its consent.