![Page 1: LocusUSA DiagnostX OTA Radio Analyzer Solution](https://reader031.fdocuments.us/reader031/viewer/2022030311/58efd3881a28abe2558b457d/html5/thumbnails/1.jpg)
Which radio is about to fail due to
Reactive Maintenance?
![Page 2: LocusUSA DiagnostX OTA Radio Analyzer Solution](https://reader031.fdocuments.us/reader031/viewer/2022030311/58efd3881a28abe2558b457d/html5/thumbnails/2.jpg)
Proactive preventative maintenance can tell
with the DiagnostX OTA Waveform Analyzer
![Page 3: LocusUSA DiagnostX OTA Radio Analyzer Solution](https://reader031.fdocuments.us/reader031/viewer/2022030311/58efd3881a28abe2558b457d/html5/thumbnails/3.jpg)
Next Generation DiagnostX
US Patents: 8565096, 8948022, 9282482, 8600371, 8825042, 9432866. Other patents pending.
TM
![Page 4: LocusUSA DiagnostX OTA Radio Analyzer Solution](https://reader031.fdocuments.us/reader031/viewer/2022030311/58efd3881a28abe2558b457d/html5/thumbnails/4.jpg)
DiagnostX is an over-the-air radio analyzer – the only one on the market. DiagnostX monitors the base station RECEIVE frequency, analyzing all control channel transmissions from the subscriber radios on the system.
4
![Page 5: LocusUSA DiagnostX OTA Radio Analyzer Solution](https://reader031.fdocuments.us/reader031/viewer/2022030311/58efd3881a28abe2558b457d/html5/thumbnails/5.jpg)
Operation
• Connect to an AC power source (100-240V, 50-60 Hz)
• Connect to an antenna: RX antenna at the multi-coupler or stand-alone antenna
• Enter Control Channel frequencies
• Define Thresholds
5
Registration
Group Affiliation
PTT
DiagnostX Viewer Console
![Page 6: LocusUSA DiagnostX OTA Radio Analyzer Solution](https://reader031.fdocuments.us/reader031/viewer/2022030311/58efd3881a28abe2558b457d/html5/thumbnails/6.jpg)
Stand-alone or System-wide Coverage
• DiagnostX DX-2002 can be used as a stand-alone unit, or it can be extended with up to three NX-200 remote receivers
• Data from the NX-200 units are sent to the DX-2002 via IP connectivity
6
![Page 7: LocusUSA DiagnostX OTA Radio Analyzer Solution](https://reader031.fdocuments.us/reader031/viewer/2022030311/58efd3881a28abe2558b457d/html5/thumbnails/7.jpg)
System-wide Coverage
7
NX-200
NX-200
IP Backhaul
NX-200
NX-200
DiagnostX Viewer Console
![Page 8: LocusUSA DiagnostX OTA Radio Analyzer Solution](https://reader031.fdocuments.us/reader031/viewer/2022030311/58efd3881a28abe2558b457d/html5/thumbnails/8.jpg)
DiagnostX is Protocol and Frequency Band Specific
Available Protocols: • P25 Trunked • P25 Conventional • SmartNet™/SmartZone™ • MOTOTRBO • EDACS • NXDN
Available Frequencies: • VHF (136-174)
• UHF (380-430 or 450-470 or 470-512)
• 700 MHz • 800 MHz • 900 MHz
8
![Page 9: LocusUSA DiagnostX OTA Radio Analyzer Solution](https://reader031.fdocuments.us/reader031/viewer/2022030311/58efd3881a28abe2558b457d/html5/thumbnails/9.jpg)
P25 Metrics and Measurements
1. Frequency Error
2. Symbol Error 600, Symbol Error 1800
3. Maximum Frequency Deviation
4. Modulation Fidelity
5. BER (on a per transmission basis, %)
6. RSSI (on a per transmission basis, dBm)
7. SNR (on a per transmission basis)
8. Reserve Gain at the multi-coupler (dBm)
9
![Page 10: LocusUSA DiagnostX OTA Radio Analyzer Solution](https://reader031.fdocuments.us/reader031/viewer/2022030311/58efd3881a28abe2558b457d/html5/thumbnails/10.jpg)
Failed Evaluation List
10
![Page 11: LocusUSA DiagnostX OTA Radio Analyzer Solution](https://reader031.fdocuments.us/reader031/viewer/2022030311/58efd3881a28abe2558b457d/html5/thumbnails/11.jpg)
Transmissions
11
![Page 12: LocusUSA DiagnostX OTA Radio Analyzer Solution](https://reader031.fdocuments.us/reader031/viewer/2022030311/58efd3881a28abe2558b457d/html5/thumbnails/12.jpg)
Reports
12
![Page 13: LocusUSA DiagnostX OTA Radio Analyzer Solution](https://reader031.fdocuments.us/reader031/viewer/2022030311/58efd3881a28abe2558b457d/html5/thumbnails/13.jpg)
Waveform Visualization
13
![Page 14: LocusUSA DiagnostX OTA Radio Analyzer Solution](https://reader031.fdocuments.us/reader031/viewer/2022030311/58efd3881a28abe2558b457d/html5/thumbnails/14.jpg)
Benefits of DiagnostX 1. Ensures operational readiness - measures radio alignment
constantly
2. Reduces maintenance costs by addressing only radios out of specification
3. The ideal complement to an auto-tune service monitor
4. Indispensible P25 migration tool
5. Completely autonomous from the radio system
14
![Page 15: LocusUSA DiagnostX OTA Radio Analyzer Solution](https://reader031.fdocuments.us/reader031/viewer/2022030311/58efd3881a28abe2558b457d/html5/thumbnails/15.jpg)
Proactive Efficient Proven
15
More information available by calling LocusUSA 321-727-3077
www.locususa.com/products/diagnostx