Load Centers & Circuit Breakers 1 - HDSupplySolutions.com

68
Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-1 1 LOAD CENTERS & CIRCUIT BREAKERS Contents Load Centers Catalog Numbering System 1-2 Siemens PL and ES Series Load Centers™ Introduction 1-3 WireGuide™ Load Centers and Breakers 1-3 PL Series Load Centers Features and Product Offering 1-4 – 1-5 PL Series Single Phase Main Lug & Main Breaker Load Centers 1-6 PL Series Single Phase Special Load Centers 1-7 PL Series Three Phase Main Lug & Main Breaker Load Centers 1-8 PL Series Three Phase Unassembled Load Centers 1-9 ES Series Load Centers Features and Product Offering 1-10 – 1-11 ES Series Single Phase Main Lug & Main Breaker Load Centers 1-12 ES Series Single Phase Special Load Centers 1-14 ES Series Three Phase Main Lug & Main Breaker Load Centers 1-15 EQ ® Load Centers, 300-400 Amp 1-16 Generator Ready Load Centers 1-17 Riser Panel Load Centers 1-18 EQ ® Load Centers, Small Circuit and Circuit Breaker Enclosures 1-19 – 1-20 Renovation Interiors 1-21 Load Centers OEM Interiors and Accessories 1-22 – 1-25 Standby Power Systems 1-26 – 1-27 Knockout Diagrams 1-28 – 1-32 Load Center Cross Reference 1-33 – 1-34 Circuit Breakers Arc-Fault and Ground-Fault Breakers 1-35 Dual Arc-Fault and Ground-Fault Breakers 1-36 Type QP, 1" Breakers 1-37 Duplex, Triplex and Quadplex Plug-In Breakers 1-38 Special Application Breakers 1-39 Type QD, 3/4" Breakers 1-40 Main and Branch Circuit Breakers 1-41 Circuit Breaker Dimension Drawings and Lug Data 1-42 – 1-43 Circuit Breaker Accessories 1-44 – 1-45 Surge Protection Products 1-46 – 1-48 AC Disconnects, 1-Phase, NEMA 3R Rated 1-49 Murray Load Centers 1-50 – 1-56 Main Lug Only and Main Breaker 1-50 – 1-51 Accessories 1-52 Catalog Logic 1-53 Cross References and Knockout Drawings 1-54 – 1-56 Murray Circuit Breakers 1-57 – 1-67 Arc-Fault Interrupters (AFCI) 1-57 1" Plug-in 1-58 – 1-59 Circuit Breaker and Surge Protective Device (SPD) 1-60 Special Application Breakers 1-61 Type MSQ, 3/4 Inch Plug-In Breakers 1-62 Main and Branch Circuit Breakers 1-63 Accessories 1-64 – 1-65 Line Diagrams and Lug Data 1-66 – 1-67 Scan to connect online to the most up-to- date version of this Section of SPEEDFAX. 1 Load Centers & Circuit Breakers SPEEDFAX TM 2017 Section PL Series Load Center WireGuide Load Center Generator Ready Load Center (Section was last modified on 03/18/19)

Transcript of Load Centers & Circuit Breakers 1 - HDSupplySolutions.com

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-1

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

C o n t e n t sLoad CentersCatalog Numbering System 1-2Siemens PL and ES Series Load Centers™ Introduction 1-3 WireGuide™ Load Centers and Breakers 1-3PL Series Load Centers Features and Product Offering 1-4 – 1-5 PL Series Single Phase Main Lug & Main Breaker Load Centers 1-6 PL Series Single Phase Special Load Centers 1-7 PL Series Three Phase Main Lug & Main Breaker Load Centers 1-8 PL Series Three Phase Unassembled Load Centers 1-9ES Series Load Centers Features and Product Offering 1-10 – 1-11 ES Series Single Phase Main Lug & Main Breaker Load Centers 1-12 ES Series Single Phase Special Load Centers 1-14 ES Series Three Phase Main Lug & Main Breaker Load Centers 1-15EQ® Load Centers, 300-400 Amp 1-16Generator Ready Load Centers 1-17Riser Panel Load Centers 1-18EQ® Load Centers, Small Circuit and Circuit Breaker Enclosures 1-19 – 1-20Renovation Interiors 1-21Load Centers OEM Interiors and Accessories 1-22 – 1-25Standby Power Systems 1-26 – 1-27Knockout Diagrams 1-28 – 1-32Load Center Cross Reference 1-33 – 1-34

Circuit BreakersArc-Fault and Ground-Fault Breakers 1-35Dual Arc-Fault and Ground-Fault Breakers 1-36Type QP, 1" Breakers 1-37Duplex, Triplex and Quadplex Plug-In Breakers 1-38Special Application Breakers 1-39Type QD, 3/4" Breakers 1-40Main and Branch Circuit Breakers 1-41Circuit Breaker Dimension Drawings and Lug Data 1-42 – 1-43Circuit Breaker Accessories 1-44 – 1-45

Surge Protection Products 1-46 – 1-48

AC Disconnects, 1-Phase, NEMA 3R Rated 1-49

Murray Load Centers 1-50 – 1-56 Main Lug Only and Main Breaker 1-50 – 1-51 Accessories 1-52 Catalog Logic 1-53 Cross References and Knockout Drawings 1-54 – 1-56

Murray Circuit Breakers 1-57 – 1-67 Arc-Fault Interrupters (AFCI) 1-57 1" Plug-in 1-58 – 1-59 Circuit Breaker and Surge Protective Device (SPD) 1-60 Special Application Breakers 1-61 Type MSQ, 3/4 Inch Plug-In Breakers 1-62 Main and Branch Circuit Breakers 1-63 Accessories 1-64 – 1-65 Line Diagrams and Lug Data 1-66 – 1-67

Scan to connect online to the most up-to-date version of this Section of SPEEDFAX.

1Load Centers & Circuit Breakers SPEEDFAXTM 2017 Section

PL SeriesLoad Center

WireGuide Load Center

Generator Ready

Load Center

(Section was last modified on 03/18/19)

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-2

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

Catalog Numbering System­

Type Enclosure or Component E = Indoor Type 1 2-10 and 30-42 circuits 300-400Amp G = Indoor Type 1 12-42 circuits W = Outdoor Type 3R I or PI = Interior R = Riser P = PL Series Indoor Type 1 12-70 circuits S = ES Series Indoor Type 1 12-70 circuits PW = PL Series Outdoor Type 3R 12-70 circuits SW = ES Series Outdoor Type 3R 12-70 circuits

Spaces Maximum number of 1" breakers

Circuits Maximum number of circuits

Type of Main ML or L = Main Lug

MB or B = Main Breaker

System 1 = 1-Phase, 3-Wire 3 = 3-Phase, 3-Wire or 3-Phase, 4-Wire

Main Ampere Rating Ex:100 = 100 Amps

Interior Blank = Standard A = Wireguide

Trim/Others Blank = Combination S = Surface F = Flush T = Feed-Thru Lugs G or GB = Ground Bar Factory Installed

Type of Bus Bar Blank = Aluminum C or CU = Copper P = Aluminum Bus, Value Pack

Trim Color Blank = Grey W = White

Products Shown In Sections 1 of this Speedfax Meet or Exceed the Following Standards.n UL50 — Electric Cabinets and Boxes

n UL67 — Electric Panelboards

n UL486 — Wire Connectors

n UL489 — Molded-Case Circuit Breakers

n UL869 — Service Equipment

n UL943 — Ground Fault interrupters(Class A — Personnel Protection)

n Federal Specification W-P-115b —Panel Power Distribution

n Federal Specification W-C-375B —Circuit Breakers

n NEC

n NEMA 250

Underwriters’ Laboratories, Inc. Reference File Numbers:n Series Connected Circuit Breaker

Information is recognized by UL under file #E10848(N)

n Load Centers Listed by UL under file #E10703

n Load Centers UL recognized compo-nents found under file #E10703, Volume 6 and 7. (Also referenced under the rec-ognized components directory — sec-tion QEUY2)

n EQ Circuit Breakers are Listed by UL under file #E82615

Load CentersCatalog Numbering System

P 12 24 B 1 100 A S CU W

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-3

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

PL Series:n Convertible

n Invertiblea

n Flush or Surface Mount Combination Covera

n Insta-wire neutrals & grounds

n Ground bars included

n Copper busbars

n Dual neutrals on all configurations

n Carton-in-carton packaging

n Lifetime warranty

ES Series:n Invertiblea

n Flush or Surface Mount Combination Covera

n Insta-wire neutrals & grounds

n Aluminum busbars

n Single sided neutral on 24 circuits and below

n Single piece carton packaging

n 10 year warranty

PL Series 3-phase ES Series 3-phase

Combination Type AFCI WireGuide Breaker

PL Series 1-phase ES Series 1-phase

WireGuide Load Centers

Load CentersSiemens PL and ES Series Load Centers™ Overview

a Applies only to NEMA 1 ES and PL Load Centers

NEW WireGuide™ Load Centers and BreakersWireGuide load centers accept new AFCIs with shortened neutral wires that slide directly into the neutral bar.

Featuresn Over 4 inches of breaker wire bending space

n 11 SKUs each available in both grey and whitea

n Pre-trimmed and ready to install neutral wires have an"Oops Loop" if extra wire is needed

n Full length neutral bars

n Decreased installation time

n WireGuide breakers available by adding "WG" suffix to existing catalog numbers. See page 1-35 for more details.

Revised on 03/31/19

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-4

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

PL Series Load CentersFeatures

The patented INSTA-WIRE™ neutral/ground system allows for faster installation because

screws are backed out, ready for wire insertion. The visible neutral and grounds system aids in the insertion of conductors.

The pre-positioned bond screw eliminates bond strap/screw assemblies, and reduces the risk of

losing components in the field.

Mounting tabs on the trim hold it in place on the load center, freeing up both hands to drive the trim screws.

The outdoor enclosure has a slide hinge door for the easiest installation and can be removed by backing out only one screw.

PL Series Load Centers ship with trims packaged separately.

All devices convertible from main lug to main breaker and vice versa.

Invertible for bottom feed application.a

Copper Bus

All devices are provided

with 2 factory installed

ground bars.

Combination head screw on the neutrals, ground, trim,

upper pan, and bond

screw provide installation

flexibility.

A rigid, sturdy base pan

provides the ruggedness

required for the

most harsh applications.

a Applies only to NEMA 1 ES and PL Load Centers

Revised on 03/02/17

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-5

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

The PL Series Load Center product line provides a wide array of variation to meet any application need.The following offering is available in the PL Series product line:

n 12-70 Circuits/Spaces

n Indoor and Outdoor enclosures

n 100 to 225 Amp

n Main Lug and Main Breakers

n Un-assembled offering in 3-phase

Un-assembled 3-phase

PL Series 1-phase Main Lug

PL Series 3-phase Main Breaker

PL Series Load CentersProduct Offering

Product Category RESI

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-6

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

a Suitable for use as service equipment.b May be installed on higher rated systems when

protected by a circuit breaker with a higher AIR rating.c Indoor enclosures are 14 1/4" wide by 3 7/8" deep.d Outdoor enclosures are 14 1/2" wide by 4 1/4" deep.e Suitable for use as service entrance equipment when

not more than six main disconnecting means are provided. See article 230.71 of the NEC®.

f 125A load centers will accept MBK100A and MBK125A. 150A load centers will accept MBK150A. 200A load centers will accept MBK200A and MBK150A. 225A load centers will accept MBK225A, MBK200A, MBK150A.

g Copper bus load centers are recommended for those applications where the environment may be severe (i.e. far and coastal areas).

h Includes all PL Series features with aluminum bussing.i Available (made to order) in white by adding "W" to the

end of the part number.

PL Series 1-Phase Main Lug & Main Breaker Load Centers1-phase, 3-wire SN, 120/240 Volts AC

Product Category RESI

Revised on 06/30/18

Main Breaker/Convertible Load Centersa Copper Busg

12-70 Circuits / 100-225 Amperes 60/75°C Rated 22,000A IRb

Amp Rating

No. of Spaces

Indoor Enclosure – NEMA Type 1 Outdoor Enclosure – NEMA Type 3R

No. of Circuits

PL Catalog Number

No. of Circuits

PL with WireGuide Interior Catalog Numberi

NEMA 1 - Enclosure Height (inches)c

No. of Circuits Catalog Number

NEMA 3R - Enclosure Height (inches) d

100

12 24 P1224B1100CU — — 18 24 PW1224B1100CU 2116 24 P1624B1100CUi — — 21 24 PW1624B1100CU 23

2020 P2020B1100CU

40 P2040B1100ACU 2420 PW2020B1100CU 27

24 P2024B1100CU — — —24 24 P2424B1100CU 48 P2448B1100ACU 24 — — —

3030 P3030B1100CU 60 P3060B1100ACU 30 — — —40 — — — — 40 PW3040B1100CU 35

125 30 30 P3030B1125CUi 60 P3060B1125ACU 30 40 PW3040B1125CU 35

15020

30 P2030B1150CU 40 P2040B1150ACU 24 — — —30 — — — — 30 PW2030B1150CU 27

3030 P3030B1150CU 60 P3060B1150ACU 30 — — —40 — — — — 40 PW3040B1150CU 35

200

20 40 P2040B1200CU 40 P2040B1200ACU 30 40 PW2040B1200CU 27

30 40P3040B1200CU 60 P3060B1200ACU 36 40 PW3040B1200CU 35P3040B1200hi 60 P3060B1200Ah 36 — — —

40 40P4040B1200CUi 80 P4080B1200ACU 36 40 PW4040B1200CU 38P4040B1200hi 80 P4080B1200Ah 36 — — —

54 70 P5470B1200CU 80 P5480B1200ACU 44 — — —

22542 60 P4260B1225CUi 80 P4280B1225ACU 39 60 PW4260B1225CU 4254 70 P5470B1225CUi 80 P5480B1225ACU 44 — — —

Single phase factory installed 22kA IR main circuit breaker offers 22/10kA IR series combination rating when using 10kA type QP, QT, QPF, QE, QN, and QAF2/QAF2C branch breakers.

Main Lug/Convertible Load Centersf Copper Busg

12-70 Circuits / 125-225 Amperes 60/75° Rated 100,000A IR

Amp Rating

No. of Spaces

Indoor Enclosure - NEMA Type 1 Outdoor Enclosure - NEMA Type 3R

No. of Circuits

PL Catalog Number

No. of Circuits

PL with WireGuide Interior Catalog Numberi

NEMA 1 - Enclosure Height (inches)c

No. of Circuits Catalog Number

NEMA 3R - Enclosure Height (inches)d

125

1212 P1212L1125CUe — — 18 12 PW1212L1125CUe 2124 P1224L1125CUe — — 18 24 PW1224L1125CUe 21

16 24 P1624L1125CU — — 21 24 PW1624L1125CU 23

2020 P2020L1125CUi

40 P2040L1125ACU24 — — —

24 P2024L1125CU 24 — — —24 40 P2440L1125CUi 48 P2448L1125ACU 24 — — —30 40 P3040L1125CUi 60 P3060L1125ACU 30 40 PW3040L1125CU 3540 40 P4040L1125CUi 80 P4080L1125ACU 36 — — —

150 20 30 P2030L1150CU 40 P2040L1150ACU 24 30 PW2030L1150CU 27

200

12 24 P1224L1200CU — — 24 24 PW1224L1200CUe 2320 40 P2040L1200CU 40 P2040L1200ACU 30 40 PW2040L1200CU 2724 40 P2440L1200CU 48 P2448L1200ACU 30 — — —

30

30 P3030L1200CU60 P3060L1200ACU 36

— — —40 P3040L1200CUi 40 PW3040L1200CU 3554 P3054L1200CU 54 PW3054L1200CU 3540 P3040L1200hi 60 P3060L1200Ah 36 — — —

4040 P4040L1200CUi 80 P4080L1200ACU 36 40 PW4040L1200CU 3840 P4040L1200h 80 P4080L1200Ah 36 — — —

22512 24 — — — 24 PW1224L1225CU 2342 60 P4260L1225CUi 80 P4280L1225ACU 39 60 PW4260L1225CU 4254 70 P5470L1225CU 80 P5480L1225ACU 44 — — —

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-7

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

a Includes all PL Series features with aluminum bussing.

b Indoor enclosures are 14 1/4" wide by 3 7/8" deep.

Split Ground Series Main Lug Convertible Load Centers Copper Bus12-60 Circuits / 125-200 Amperes 60/75° Rated, 100,000A IRBranch Circuits Indoor Enclosure – NEMA Type 1

Amp Rating

No. of Spaces

No. of Circuits Catalog Number

Enclosure Height (inches)b

125 12 24 P1224L1125CUSG 18

125 16 24 P1624L1125CUSG 21

125 20 30 P2030L1125CUSG 24

125 24 30 P2430L1125CUSG 24

150 20 30 P2030L1150CUSG 24

200 30 40 P3040L1200CUSG 36

200 30 40 P3040L1200SGa 36

200 40 40 P4040L1200CUSG 36

200 40 40 P4040L1200SGa 36

225 40 60 P4260L1225CUSG 39

First Surge PL Load Centers Copper Bus54-60 Circuits 60/75° Rated, 22,000A IRAmp Rating

No. of Spaces

No. of Circuits Catalog Number

Surge Protection

Enclosure Height (inches)b

200 30 54 P3054B1200S140 140kA 36

200 40 60 P4060B1200S140 140kA 42

Split Ground Series Main Breaker Convertible Load Centers Copper Bus40 Circuits / 200 Amperes 60/75° Rated, 22,000A IRc

Branch Circuits Indoor Enclosure – NEMA Type 1

Amp Rating

No. of Spaces

No. of Circuits Catalog Number

Enclosure Height (inches)b

200 40 40 P4040B1200CUSG 36

Outdoor Trailer Panels Copper Bus16 Circuits / 200 Amperes 60/75° Rated, 22,000A IRe

Amp Rating

No. of Spaces

No. of Circuits Catalog Number Main Breaker

Enclosure Height (inches)d

200 8 16 PW0816L1200TC MBK150A or MBK200A Field Installed 23

200 8 16 PW0816B1200TC MBK200A Factory Installed 23

c May be installed on higher rated systems when pro-tected by a circuit breaker with a higher AIR rating.

d Outdoor enclosures are 14 1/2" wide by 4 1/4" deep.e Main lug panel rated 100,000A IR.

Split Ground Load Centers have factory installed 100%

neutral with factory bonded 75% ground. No neutral tie strap.

f Load centers with white trim have increased lead time of 3-4 weeks. Sold in pallet quantities only.

g Load centers with CUW suffix indicates copper bus with white trim. Load centers with W suffix only indicates aluminum bus with white trim.

PL Series 1-Phase Special Application Load Centers1-phase, 3-wire SN, 120/240 Volts AC

Product Category RESI

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-8

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

Main Breaker/Convertible Load Centers Copper Bush

30-70 Circuits / 100-225 Amperes 60/75°C Rated 22,000A IRa

Branch Circuits Indoor Enclosure – NEMA Type 1 Outdoor Enclosure – NEMA Type 3R

Amp Rating

No. of Spaces

No. of Circuits Catalog Number

Enclosure Height (inches)c Catalog Number

Enclosure Height (inches)d

100 12 24 P1224B3100CUb 24 — —100 30 42 P3042B3100CUb 30 — —125 30 30 P3030B3125CU 39 — —150 24 42 P2442B3150CU 36 — —150 42 42 P4242B3150CU 42 — —200 30 54 P3054B3200CU 39 PW3054B3200CU 38200 42 60 P4260B3200CU 42 PW4260B3200CU 42225 42 60 P4260B3225CU 42 — —225 42 60 P4260B3225TCUf 49 — —225 54 70 P5470B3225CU 49 — —

Main Lug/Convertible Load Centerse Copper Bush

12-70 Circuits / 125-225 Amperes 60/75° Rated 100,000A IRi

Branch Circuits Indoor Enclosure – NEMA Type 1 Outdoor Enclosure – NEMA Type 3R

Amp Rating

No. of Spaces

No. of Circuits Catalog Number

Enclosure Height (inches)c Catalog Number

Enclosure Height (inches)d

125 12 24 P1224L3125CUg 21 PW1224L3125CUg 21200 24 42 P2442L3200CU 36 PW2442L3200CU 35200 30 54 P3054L3200CU 39 PW3054L3200CU 38225 42 60 P4260L3225CU 42 PW4260L3225CU 42225 54 70 P5470L3225CU 49 — —

a May be installed on higher rated systems when pro-tected by a circuit breaker with a higher AIR rating.

b Back fed main breaker.c Indoor enclosures are 14 1/4" wide by 3 7/8" deep.d Outdoor enclosures are 14 1/2" wide by 4 1/4" deep.

e Suitable for use as service entrance equipment when not more than six main disconnecting means are provided. See article 230.71 of the NEC®.

f Includes factory installed feed through lugs and is also non-convertible.

g Non-convertible to main breaker.h All load centers are provided with tin plated copper bus bars.

i Rated 100,000A IR in series with breakers listed on wiring diagram.

All load centers are provided with tin-plated copper bus bars.

Available (made to order) in white by adding "W" to the end of the part number

PL Series 3-Phase Main Lug & Main Breaker Load Centers3-phase, 3-wire, 240 Volt AC or 3-phase, 4-wire, 120/240 or 120/208 Volts AC

Product Category RESI

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-9

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

Main Breaker Convertible Unassembled Load Centers Copper Buse

24-70 Circuits / 100-225 Amperes 60/75°C Rated 22,000A IRa

Interiors Enclosure Trim Kit

Amp Rating

No. of Spaces

No. of Circuits

Interior Catalog Number

Enclosure Height (inches)c

Enclosure Catalog Number

No. Breaker Spaces

Trim Catalog Numbere

100 30 42 PI3042B3100CUb 30 3PE30 30 PT3042B3100150 24 42 PI2442B3150CU 36 3PE36 24 PT2442X3150200 30 54 PI3054B3200CU 39 3PE39 30 PT3054X3200200 42 60 PI4260B3200CU 42 3PE42 42 PT4260X3200225 54 70 PI5470B3225CU 49 3PE49 54 PT5470X3225

Main Lug Convertible Unassembled Load Centers Copper Buse

12-70 Circuits / 125-225 Amperes 60/75° Rated 100,000A IRf

Interiors Enclosure Trim Kit

Amp Rating

No. of Spaces

No. of Circuits

Interior Catalog Number

Enclosure Height (inches)c

Enclosure Catalog Number

No. Breaker Spaces

Trim Catalog Numberd

125 12 24 PI1224L3125CU 21 3PE21 12 PT1224L3125 200 24 42 PI2442L3200CU 36 3PE36 24 PT2442X3200200 30 54 PI3054L3200CU 39 3PE39 30 PT3054X3200 225 42 60 PI4260L3225CU 42 3PE42 42 PT4260X3225 225 54 70 PI5470L3225CU 49 3PE49 54 PT5470X3225

a May be installed on higher rated systems when pro-tected by a circuit breaker with a higher AIR rating.

b Back fed main breaker.c Indoor enclosures are 14 1/4" wide by 3 7/8" deep.

d Trim catalog numbers with a “B” indicate for use with main breaker and is not convertible. “L” indicates for use with main lug and is not convertible. “X” indicates can be used with convertible interior.

e All load center interiors are provided with tin plated copper bus bars.

f Rated 100,000A IR in series with breakers listed on wiring diagram.

PL Series 3-Phase Unassembled Load Centers3-phase, 3-wire, 240 Volt AC or 3-phase, 4-wire, 120/240 or 120/208 Volts AC

Product Category RESI

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-10

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

The patented INSTA-WIRE™ neutral/ground system allows for faster installation because

screws are backed out, ready for wire insertion. The visible neutral and grounds system aids in the insertion of conductors.

The pre-positioned bond screw eliminates bond strap/screw assemblies, and reduces the risk of

losing components in the field.

Mounting tabs on the trim hold it in place on the load center, freeing up both hands to drive the trim screws.

The outdoor enclosure has a slide hinge door for the easiest installation and can be removed by backing out only one screw.

ES Series Load Centers ship in single piece carton.

Invertible for bottom feed application.a

Aluminum bus.

Combination head screw on the neutrals, ground, trim,

upper pan, and bond

screw provide installation

flexibility.

A rigid, sturdy base pan

provides the ruggedness

required for the

most harsh applications.

Single side inboard neutral on 24 circuits and below; dual on

30 circuits and above.

Ground bar field installed (select skus with “G”

suffix will have ground bar factory installed).

ES Series Load CentersFeatures

a Applies only to NEMA 1 ES and PL Load Centers

Revised on 03/02/17

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-11

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

The ES Series Load Center product line provides a wide array of variation to meet any application need.

The following offering is available in the ES Series product line:

n 12-70 Circuits/Spaces

n Indoor and Outdoor enclosures

n 100 to 225 Amp

n Main Lug and Main Breakers

n Value packs – a mix of branch breakers provided with the load center.

ES Series1-phase Main Lug

125A, 12-24 circuits

ES Series1- phase Main Breaker

125- 225A, 30-70 circuits

ES Series3-phase Main Breaker

ES Series Load CentersProduct Offering

Product Category RESI

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-12

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

a Suitable for use as service equipment.b May be installed on higher rated systems when pro-

tected by a circuit breaker with a higher AIR rating.c Indoor enclosures are 14 1/4" wide by 3 7/8" deep.

d Outdoor enclosures are 14 1/2" wide by 4 1/4" deep.e Suitable for use as service entrance equipment when

not more than six main disconnecting means are pro-vided. See article 230.71 of the NEC®.

f ES Series single phase skus with a "G" suffix have ground bar included (factory installed).

g Line and Neutral Lug Wire Range: 500 kcmil - #2 AL/CUh Available (made to order) in white by adding "W" to the

end of the part number.

ES Series 1-Phase Main Lug & Main Breaker Load Centers1-phase, 3-wire SN, 120/240 Volts AC

Product Category RESI

Revised on 11/29/17

Main Breakera Aluminum Bus12-70 Circuits / 100-225 Amperes 60/75°C Rated 22,000A IRb

Amp Rating

No. of Spaces

Indoor Enclosure – NEMA Type 1 Outdoor Enclosure – NEMA Type 3R

No. of Circuits

ES Catalog Number

No. of Circuits

ES with WireGuide Interior Catalog Numberh

NEMA 1 - Enclosure Height (inches)c

No. of Circuits Catalog Number

NEMA 3R - Enclosure Height (inches)d

100

10 20 S1020B1100 — — 18 — — —12 24 S1224B1100 — — 18 24 SW1224B1100 2116 24 S1624B1100h — — 21 24 SW1624B1100 23

2020 S2020B1100

40 S2040B1100A 2420 SW2020B1100 27

24 S2024B1100 — — —30 30 S3030B1100h 60 S3060B1100A 30 — — —

125

12 24 — — — — 24 SW1224B1125 21

1624 S1624B1125 — — 21 — —32 — — — — 24 SW2024B1125 27

24 24 S2424B1125h 48 S2448B1125A 24 24 SW2424B1125 27

3030 S3030B1125h

60 S3060B1125A 30— — —

40 S3040B1125 40 SW3040B1125 35

150

16 30 S1630B1150 — — 24 — — —20 30 S2030B1150 40 S2040B1200A 24 — — —24 30 S2430B1150 48 S2448B1200A 30 — — —

3030 S3030B1150h

60 S3060B1150A 30— — —

40 S3040B1150 40 SW3040B1150 3540 40 — — — — 40 SW4040B1150 38

200

16 32 S1632B1200 — — 24 — — —20 40 S2040B1200 40 S2040B1200A 30 40 SW2040B1200 2724 40 S2440B1200 48 S2448B1200A 30 — — —30 40 S3040B1200h 60 S3060B1200A 36 40 SW3040B1200 3540 40 S4040B1200h 80 S4080B1200A 36 40 SW4040B1200 3842 60 S4260B1200 80 S4280B1200A 39 — — —54 70 S5470B1200 80 S5480B1200A 44 — — —

22542 60 S4260B1225 80 S4280B1225A 39 60 SW4260B1225 4254 70 S5470B1225 80 S5480B1225A 44 — — —

Main Lug Aluminum Bus12-70 Circuits / 125-225 Amperes 60/75° Rated 100,000A IR

Amp Rating

No. of Spaces

Indoor Enclosure - NEMA Type 1 Outdoor Enclosure - NEMA Type 3R

No. of Circuits

ES Catalog Number(6)

No. of Circuits

ES with WireGuide Interior Catalog Numberfh

NEMA 1 - Enclosure Height (inches)c

No. of Circuits Catalog Number

NEMA 3R - Enclosure Height (inches)d

125

1212 S1212L1125e — — 18 12 SW1212L1125e 2124 S1224L1125e — — 18 24 SW1224L1125e 21

16 24 S1624L1125 — — 21 24 SW1624L1125 21

20

20 S2020L1125h

40 S2040L1125AG 21

— — —20 S2020L1125Gh —— — —24 S2024L1125 — — —24 S2024L1125G — — —

24

24 S2424L1125h

48 S2448L1125AG 24

24 SW2424L1125 2724 S2424L1125Gh — — —40 S2440L1125h — — —40 S2440L1125G — — —

3040 S3040L1125h —

S3060L1125AG 3040 SW3040L1125 29

40 S3040L1125Gh — — — —40 40 S4040L1125 80 S4080L1125AG 36 — — —

150 20 30 S2030L1150h 40 S2040L1150AG 24 30 SW2030L1150 27

200

12 24 S1224L1200e — 21 24 SW1224L1200e 2120 40 S2040L1200 40 S2040L1200AG 24 40 SW2040L1200 2724 40 S2440L1200h 48 S2448L1200AG 30 — — —

30

30 S3030L1200h

60 S3060L1200AG 30— — —

40 S3040L1200h 40 SW3040L1200 3554 S3054L1200 54 SW3054L1200 3540 S3040L1200L50g — — 36 — — —

40 40 S4040L1200h 80 S4080L1200AG 36 40 SW4040L1200 35

22512 24 — — — — 24 SW1224L1225 2342 60 S4260L1225 80 S4280L1225AG 36 60 SW4260L1225 3854 70 S5470L1225 80 S5480L1225AG 42 — — —

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-13

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

a Suitable for use as service equipment.b May be installed on higher rated systems when pro-

tected by a circuit breaker with a higher AIR rating.

Featuresn Available for the most popular ES Load Centers

n Gives the ability to order in bulk

n Enclosures will have minimal packaging for less hassle and waste at the job site

n Keeps the covers separate to prevent damage or theft

n Includes full size cardboard covers to keep the interior safe during painting

n All main lug panels include factory installed ground bars

Main Breaker ES Unassembled Load Centersa Aluminum Bus24-40 Circuits / 125-200 Amperes 60/75° Rated 22,000A IRb

Amp Rating Box Catalog Number Main

No. of Spaces

No. of Circuits

Dimensions Trim Catalog Number

Pallet QuantityHeight Width Depth

125 SB2424B1125 Main Breaker 24 24 24 14.5 4.25 ST2424B1125 36

200 SB3040B1200 Main Breaker 30 40 36 14.5 4.25 ST3040B1200 30

200 SB4040B1200 Main Breaker 40 40 36 14.5 4.25 ST4040B1200d 30

Main Lug ES Unassembled Load Centersc Aluminum Bus24-40 Circuits / 125-200 Amperes 60/75° Rated 100,000A IR

Amp Rating Box Catalog Number Main

No. of Spaces

No. of Circuits

Dimensions Trim Catalog Number

Pallet QuantityHeight Width Depth

125 SB2440L1125G Main Lug 24 40 24 14.5 4.25 ST2440L1125 36

125 SB3040L1125G Main Lug 30 40 30 14.5 4.25 ST3040L1125 36

200 SB3040L1200G Main Lug 30 40 30 14.5 4.25 ST3040L1200 36

200 SB4040L1200G Main Lug 40 40 36 14.5 4.25 ST4040L1200 30

Selectable Main ES Unassembled Load Centersc Aluminum Bus30-40 Circuits / 200 Amperes

Amp Rating Box Catalog Number Main

No. of Spaces

No. of Circuits

Dimensions Trim Catalog Number

Pallet QuantityHeight Width Depth

150/200 SB3040C1200G Convertible 30 40 36 14.5 4.25 ST3040X1200 30

150/200 SB4040C1200G Convertible 40 40 36 14.5 4.25 ST4040X1200 30

c ES Series single phase skus with a "G" suffix have ground bar included (factory installed).

d Available (made to order) in white by adding "W" to the end of the part number.

ES Series 1-Phase Unassembled Load Centers1-phase, 3-wire SN, 120/240 Volts A

Revised on 04/20/17

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-14

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

Outdoor Trailer Panels Aluminum Bus16 Circuits / 200 Amperes 60/75° Rated 100,000A IRAmp Rating

No. of Spaces

No. of Circuits Catalog Number Main Breaker

Enclosure Height (inches)d

200 8 16 SW0816L1200T N/A N/A 23

200 8 16 SW0816B1200Te MBK200A Factory Installed 23

Split Ground Series Load Centersf

30-40 Circuits / 125-200 Amperes16 Circuits / 200 Amperes Aluminum BusBranch Circuits Indoor Enclosure – NEMA Type 1

Amp Rating

No. of Spaces No. of Circuits Catalog Number

Enclosure Height (inches)b

125 20 30 S2030L1125SG 21

150 30 30 S3030B1150SG 30

200 40 40 S4040B1200SG 36

Selectable Main Load Centersg

24-40 Circuits / 125-200 Amperes Aluminum BusBranch Circuits Indoor Enclosure – NEMA Type 1 Outdoor Enclosure – NEMA Type 3R Available Kits

Amp Rating

No. of Spaces

No. of Circuits Catalog Number

Enclosure Height (inches)b Catalog Number

Enclosure Height (inches)d Main Lug Main Breaker

125 24 24 S2424C1125 24 SW2424C1125 27 ECMLK125 MBK100A, MBK125A

200 20 40 S2040C1200 35 SW2040C1200 35 ECMLK225 MBK200A

200 30 40 S3040C1200 36 SW3040C1200 35 ECMLK225 MBK150A, MBK200A

200 40 40 S4040C1200 36 SW4040C1200 38 ECMLK225 MBK150A, MBK200A

Value Pack Load Centersc Aluminum Bus

Catalog Number Load Center Breakers Included AmpN0. of Spaces

No. of Circuits

S2020B1100P S2020B1100 (3) Q120, (1) Q230 100 20 20S3040B1200P S3040B1200 (3) Q120, (1) Q230 200 30 40S3040L1200P S3040L1200 (3) Q120, (1) Q230 200 30 40S4040B1200P S4040B1200 (3) Q120, (1) Q230 200 30 40S3054B1200P N/A (3) Q120, (1) Q230 200 30 54

a Load centers with white trim have increased lead time of 3-4 weeks. Sold in pallet quantities only. Additional charge will apply. Contact sales office for details.

b Indoor enclosures are 14 1/4" wide by 3 7/8" deep.

c Breakers are shipped inside a sleeve located inside the load center.

d Outdoor enclosures are 14 1/2" wide by 4 1/4" deep.e Main breaker rated 22,000A IR.

f Split Ground load centers have factory installed 100% neutral with factory bonded 75% ground.

g Selectable main load centers do not come with main lugs or main breakers. Those kits are sold separately.

First Surge ES Load Centers Aluminum Bus54-60 Circuits 60/75° Rated, 22,000A IRAmp Rating

No. of Spaces

No. of Circuits Catalog Number

Surge Protection

Enclosure Height (inches)b

200 30 54 S3054B1200S060 60kA 36

200 40 60 S4060B1200S060 60kA 42

ES Series 1-Phase Special Load Centers1-phase, 3-wire SN, 120/240 Volts AC

Product Category RESI

Revised on 04/20/17

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-15

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

Main Breaker Aluminum Bus30-60 Circuits / 100-225 Amperes 60/75°C Rated 10,000A IRa

Branch Circuits Indoor Enclosure – NEMA Type 1 Outdoor Enclosure – NEMA Type 3R

Amp Rating

No. of Spaces

No. of Circuits Catalog Number

Enclosure Height (inches)c Catalog Number

Enclosure Height (inches)d

100 12 24 S1224B3100b 24 SW1224B3100 23100 30 30 S3030B3100b 30 — —100 30 42 S3042B3100b 30 — —125 30 42 S3042B3125 35 — —150 24 42 S2442B3150 36 SW2442B3150 35150 42 42 S4242B3150 42 — —150 30 54 S3054B3150 35 — —200 30 54 S3054B3200 39 SW3054B3200 38200 42 60 S4260B3200 42 SW4260B3200 42225 42 42 S4242B3225 42 SW4242B3225 42

Main Luge Aluminum Bus12-70 Circuits / 125-225 Amperes 60/75° Rated 100,000A IRf

Branch Circuits Indoor Enclosure – NEMA Type 1 Outdoor Enclosure – NEMA Type 3R

Amp Rating

No. of Spaces

No. of Circuits Catalog Number

Enclosure Height (inches)c Catalog Number

Enclosure Height (inches)d

125 12 24 S1224L3125 21 SW1224L3125 21150 18 36 S1836L3150 24 SW1836L3150 23150 24 42 S2442L3150 30 SW2442L3150 27200 12 24 S1224L3200 21 SW1224L3200 21200 24 42 S2442L3200 30 SW2442L3200 27200 30 54 S3054L3200g 30 SW3054L3200 35225 42 60 S4260L3225g 36 SW4260L3225 38225 54 70 S5470L3225g 42 — —

a May be installed on higher rated systems when pro-tected by a circuit breaker with a higher AIR rating.

b Back fed main breaker.c Indoor enclosures are 14 1/4" wide by 3 7/8" deep.

d Outdoor enclosures are 14 1/2" wide by 4 1/4" deep.e Suitable for use as service entrance equipment when

not more than six main disconnecting means are provided. See article 230.71 of the NEC®.

f Rated 100,000A IR in series with breakers listed on wiring diagram.

g Available (made to order) in white by adding "W" to the end of the part number.

ES Series 3-Phase Main Lug & Main Breaker Load Centers3-phase, 3-wire, 240 Volt AC or 3-phase, 4-wire, 120/240 or 120/208 Volts AC

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-16

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

Product Category RESI

a Indoor and outdoor enclosures are 20" wide by 6" deep.b Dual Main provisions. Has factory installed 200 amp MD-TR

main breaker with provision for second MD-TR main breaker up to 200 amps to feed sub-panl or other large loads.

Featuresn UL listed for 60/75°C conductors.

See equipment markings for applications.

n Copper bus standard.

n Factory installed lock on indoor enclosures.

n Outdoor enclosures use HV type hubs. See page 1-23.

n Main breaker units have a factory installed JXD2 type breaker.

E3030MB1400SCU

EQ® Load Centers—300-400 Amp1-Phase, 3-Wire/3-Phase, 3-Wire, 4-Wire

Revised on 03/31/19

Main Breaker 300-400 Amperec 120/240 Volts AC1Ø, 3-Wire 65,000A IRBranch Circuits Indoor Enclosure – NEMA Type 1 Outdoor Enclosure – NEMA Type 3R

Amp Rating

No. of Spaces

No. of Circuits

Siemens Catalog Number

Murray Catalog Number

Enclosure Heighta Trim Style

Siemens Catalog Number

Murray Catalog Number

Enclosure Heighta

30042 42 E4242MB1300FCU — 58 Flush — — —42 42 E4242MB1300SCU — 58 Surface — — —

400

30 30 — LC330SSbf 47 Surface — — —30 30 E3030MB1400SCU — 52 Surface W3030MB1400CU — 5242 42 E4242MB1400FCU — 58 Flush — — —42 42 E4242MB1400SCU LC442SSg 58 Surface W4242MB1400CU LW442SRg 58

240 Volts AC3Ø, 3-Wire, 4-Wire 65,000A IRBranch Circuits Indoor Enclosure – NEMA Type 1 Outdoor Enclosure – NEMA Type 3R

Amp Rating

No. of Spaces

No. of Circuits

Siemens Catalog Number

Murray Catalog Number

Enclosure Heighta Trim Style

Siemens Catalog Number

Murray Catalog Number

Enclosure Heighta

300 42 42 E4242MB3300SCU — 58 Surface — — —

40030 30 E3030MB3400SCU — 52 Surface — — —42 42 E4242MB3400FCU — 58 Flush — — —42 42 E4242MB3400SCU LP442SSh 58 Surface W4242MB3400CU LZ442SRh 58

Main Lug 400 Ampere 120/240 Volts AC1Ø, 3-Wire 65,000A IRBranch Circuits Indoor Enclosure – NEMA Type 1 Outdoor Enclosure – NEMA Type 3R

Amp Rating

No. of Spaces

No. of Circuits

Siemens Catalog Number

Murray Catalog Number

Enclosure Heighta Trim Style

Siemens Catalog Number

Murray Catalog Number

Enclosure Heighta

400

12 6 — — — — W0606ML1400CUdeg — 4330 30 E3030ML1400SCU — 41 Surface W3030ML1400CU — 4342 42 E4242ML1400FCU — 47 Flush — — —42 42 E4242ML1400SCU LC042SSf 47 Surface W4242ML1400CU LW042SRf 47

240 Volts AC3Ø, 3-Wire, 4-Wire 22,000A IRBranch Circuits Indoor Enclosure - NEMA Type 1 Outdoor Enclosure - NEMA Type 3R

Amp Rating

No. of Spaces

No. of Circuits

Siemens Catalog Number

Murray Catalog Number

Enclosure Heighta Trim Style

Siemens Catalog Number

Murray Catalog Number

Enclosure Heighta

40030 30 E3030ML3400SCU — 41 Surface — — —42 42 E4242ML3400FCU — 47 Flush — — —42 42 E4242ML3400SCU LP042SS 47 Surface W4242ML3400CU LW942SRh 47

c UL listed as suitable for use as service equipment.d Accepts up to six QN style breakerse Suitable for use as service entrance equipment when not

more than six main disconnecting means are provided.

f 50,000A IRg 22,000A IRh 10,000A IR

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-17

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

Generator Ready Load CentersThe Siemens generator ready load center can save thousands of dollars in future generator installation expenses while keeping initial expenses to a minimum. Works with an automatic standby generator or a portable generator.

Load Center Features

n UL Listed

n Indoor Type 1 and outdoor Type 3R

n 225A max rated

n Flush or surface mounting

n Fits between standard stud centers

n Tin plated copper bus bars

n 22 kAIC rated

n 120/240V ~

n Main lug – convertible to main breaker with addition of MBK150A, MBK200A, or MBK225A

n Installation of transfer mechanism can be performed at time of generator installation

Automatic transfer switch features:n UL Listed

n Operates automatically when connected to generator

n Transfers load from utility to generator and back to utility

n Transfer switch (sold separately) catalog number: GENTFRSWTCHac

a Q2125S provided with GENTFRSWTCH for use with automatic transfer mechanism.

b 2 spaces and 2 circuits are reserved for standby generator installation.

GENTFRSWTCH

NEMA 1

NEMA 3R

c Field install breaker for voltage sensing required.d Indoor enclosures are 14 1/4" wide by 3 7/8" deep.e Outdoor enclosures are 14 1/2" wide by 4 1/4" deep.

Generator Ready Load Centers1-Phase, 3-WIre SN, 120/240Volts AC

Revised on 03/31/19

Indoor Enclosure – NEMA Type 1Amp Rating

No. of Spacesb

No. of Circuitsb

Siemens Catalog Number

Murray Catalog Number Main

Enclosure Heightd

200 30 42 G3042B1200GEN LC3042B1200GEN Main Breaker 42225 30 42 G3042L1225GEN LC3042L1225GEN Main Lug 42200 42 54 G4254B1200GEN — Main Breaker 44225 42 54 G4254L1225GEN - Main Lug 44

Outdoor Enclosure – NEMA Type 3RAmp Rating

No. of Spacesb

No. of Circuitsb

Siemens Catalog Number

Murray Catalog Number Main

Enclosure Heighte

200 30 42 W3042B1200GEN - Main Breaker 42225 30 42 W3042L1225GEN - Main Lug 42

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-18

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

Riser Panel Load Centersa

Riser panel load centers are ideal for high rise applications. The shifted interior provides room for conductors to pass through the load center. The tap kits allow the installer to tap off from those conductors to power the panel.

Featuresn UL Listed for use in 1Ø and 3Ø riser gutter applications.

n Copper bus standard.

n Main lug factory standard - convertible to main breaker.

n Neutrals aligned on left side- keeps way clear for riser cables.

n Available in 125 and 200 amp models.

n Invertible for left and right hand applications.

Riser Gutter Tap Kitb

The riser gutter tap kit (ECRLK250) allows the installer to tap off the main conductors, eliminating the need to cut completely through the conductor. The tap kit accepts 250 -1/0 on the main conductor side and 250-#6 on the tap side.

Riser GutterThe riser gutter (RAG24) is used to convert anyload center 24” or larger into a riser panel.

Featuresn Single and 3-phase applications

n Compatible with any single or 3-phase Siemens load center 24" or higher

n Flush trim included

n Load center mounting hardware and pass through brush included (Catalog no. RAG24)

1-phase, 3-wire SN, 120/240 Volts AC

Amp Rating

No. of Spaces

No. of Circuits

Catalog Number Dimensions (inches)

Acceptable Main Breaker KitsAluminum Bus

Aluminum Bus White Coating Copper Bus

Copper Bus White Coating Height Width Depth

125 16 32 R1632L1125 R1632L1125W R1632L1125CU — 24 14.25 3.88 MBK100A,MBK125A125 24 24 R2424L1125 R2424L1125W R2424L1125CU — 30 14.25 3.88 MBK100A, MBK125A125 24 42 R2442L1125 R2442L1125W R2442L1125CU R2442L1125CUW 30 14.25 3.88 MBK100A, MBK125A200 30 42 R3042L1200 R3042L1200W R3042L1200CU R3042L1200CUW 36 14.25 3.88 MBK150A, MBK200A

a The riser panels are single phase only, but can be fed from 1-phase or 3-phase systems running through the gutter trough area.

b ECRLK250 is sold separately

RAG24Any Load Center24" or larger

Riser Panel Load Centers1-Phase, 3-WIre SN, 120/240Volts AC

ECRLK250

R1632L1125CU

Revised on 04/20/17

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-19

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

a Suitable for use as service equipment when a main breaker (100A maximum) is used with retainer clip (Cat. No. ECMBR1).

b Two Q115 or MP115 and one Q130 or MP130 included c 22KAIC Main Breaker factory installedd 70 amp maximum breaker.e Suitable for use as service entrace equipment when a

main breaker (70A maximum) is used with reatiner clip (Cat. No. ECMBR1).

f Will not accommodate a 2-pole circuit breaker with shunt trip.

g Suitable for use as service equipment when not more than six main disconnecting means are provided. Check local codes and restrictions.

h Packaged in quantities of 5.i CSA Listed No Door 10KAIC Main Breaker factory installed

l l2-pole 60A GFCI, a restriction of #6 wire applies due to wire bend space of the enclosure.

m Suffix SPA50 indicates a factory installed 50A 2-pole GFCI and suffix SPA60 indicates a factory installed 60A 2-pole GFCI.

n Suitable only for use as service equipment.o Requires field installed main and retainer clip

(Cat. No. ECLX378M).

Features/Applicationsn Indoor and Outdoor Applications

n UL Listed

n 2 to 12 Space Options

n SPA panels offer a 50A or 60A factory installed GFCI breaker

n Service Entrance or Subfeed Applications

Renovation PanelIdeal for older home renovation projects where the distance between the studs is narrower than current construction practices. The narrower panel eliminates the need to ‘notch’ out the existing studs.

Spa PanelsSpa Panels are ideal for outdoor applications requiring the use of ground fault protection, such as hot tubs. A factory installed 2-Pole GFCI breaker is provided, along with 2 extra circuits.

Product Category RESI

Small Circuit Load CentersIdeal for subfeed applications

EQ® Load Centers—Small Circuit Load Centers1-Phase, 3-WIre SN, 120/240Volts AC�

Amp Rating

No. of Spaces

No. of Circuits

Indoor Enclosure - NEMA Type 1

Siemens Catalog Number

Murray Catalog Number

Max Short Circuit Rating

Bus Material Mounting

Phase Lug Wire Size Ground Bar

Dimensions (inches)

H W D

10010 20 E1020MB1100FCGPabc LC110DFCGPabc 22,000 Copper Flush

CU or AL #4 - 2/0 AWG

ECGB10 Installed14.6 12.3 3.7

12 24E1224ML1100FGde — 100,000 Aluminum Flush 14.6 12.3 3.7E1224ML1100FCUde — 100,000 Copper Flush Use ECGB kits 14.6 12.3 3.7

125

4 8E0408ML1125Ffghi LC004NFfgh 100,000 Aluminum Flush AL #12 - 2/0 AWG

or CU #14 - 2/0 AWG Use ECGB or

ECLX kits

12.8 6.5 3.3

E0408ML1125Sfghi LC004NSfgh 100,000 Aluminum Surface 12.8 6.5 3.3

8 16

E0816ML1125Fgi LC008DFg 100,000 Aluminum Flush

CU or AL #4 - 2/0 AWG

14.6 12.3 3.7E0816ML1125Sgi LC008DSg 100,000 Aluminum Surface 14.6 12.3 3.7

E0816ML1125FGBg LC008DFGg 100,000 Aluminum Flush ECGB10 or ECLX071M Installed 14.6 12.3 3.7

— LC008DSGg 100,000 Aluminum Surface ECLX071M Installed 14.6 12.3 3.7E0816ML1125FCUg — 100,000 Copper Flush

Use ECGB kits14.6 12.3 3.7

E0816ML1125SCUg — 100,000 Copper Surface 14.6 12.3 3.7

Amp Rating

No. of Spaces

No. of Circuits

Outdoor Enclosure - NEMA Type 3R

Siemens Catalog Number

Murray Catalog Number

Max Short Circuit Rating

Bus Material

Hub Provision

Phase Lug Wire Size Ground Bar

Dimensions (inches)

H W D

100 2 4 W0204MB1100cg LW102NLgh 100,000 Aluminum 1.25” HS Hub AL #12 - 2/0 AWG

or CU #14 - 2/0 AWG

Use ECGB or ECLX kits

12.1 6.2 4.4

1254 8

W0408ML1125fhil LW004NRfhl 100,000 Aluminum

HS Cover Plate

12.1 6.2 4.4W0408L1125SPA50lm LW004NRSPA50lm 100,000 Aluminum

ECGB5 Installed12.1 6.2 4.4

W0408L1125SPA60lm LW004NRSPA60lm 100,000 Aluminum 12.1 6.2 4.4

8 16 W0816ML1125CUgi LW008NRg 100,000 Copper

CU or AL #4 - 2/0 AWG

Use ECGB or ECLX kits 14.7 12.1 4.1

150 4 4 W0404MB1150CTScn — 22,000 Copper

ECLX384M Installed

20.0 11.1 4.7

200 4

8— LW004TRno 100,000 Aluminum 20.0 11.1 4.7— LW204TLn 100,000 Aluminum 2” HS

Hub20.0 11.1 4.7

4W0404MB1200CTn — 22,000 Copper 20.0 11.1 4.7

W0404MB1200CTSn — 22,000 Copper HS Cover Plate 20.0 11.1 4.7

Revised on 03/31/19

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-20

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

a Additional breaker types may be listed on the wiring diagram.

b Will not accommodate 2-pole GFCI or Circuit breaker with shunt trip.

c Can accommodate 2-pole GFCI breaker up to 60A.

d CSA Listede Will not accommodate circuit breaker with shunt trip.f Series rating

Featuresn Circuit breaker enclosures range from

60A to 250A, indoor and outdoor models

n UL listed

n Suitable for use as service entrance equipment

n UL listed for 60/75°C Conductors (See equipment markings for applications)

n Outdoor type 3R devices use HS type hubs (pg. 1-22) except for the W0204ML1060 which uses HA type hubs

W0202MB1200CU E0303ML3100CU

EQ® Load Centers—Circuit Breaker Enclosures1-Phase and 3-Phase, 240V AC Max.

Product Category RESI

Revised on 03/31/19

Amp Rating

No. of Poles

Indoor Enclosure - NEMA Type 1 Outdoor Enclosure - NEMA Type 3R

Catalog NumberBreaker Useda

Max Short Circuit Rating

Std. Pkg.

Dimensions (inches)

Catalog NumberBreaker Useda

Max Short Circuit Rating

Std. Pkg.

Dimensions (inches)

H W D H W D

1-Phase, 3-Wire SN - 120/240 Volts AC - Breaker Factory Installed

100 2E0202MB1100 Q2100

22,000 1 17.3 7.3 4.3W0202MB1100CU Q2100

22,000 1 17.2 7.3 4.3LC100CS MP2100 LW100CR MP2100

150 2 — — — — — — — W0202MB1150CU QN2150H 65,000 1 19.8 8.7 5

200 2E0202MB1200 QN2200 22,000 1 20 8.7 4 W0202MB1200CU QN2200HLC200VS MPD2200 22,000 1 20 8.7 4 LW200VR MPD2200

150 2 — — — — — — — WB2150BQR QR22B150L 10,000 1 26.9 7.1 4.4200 2 — — — — — — — WB2200BQR QR22B200L

225 2 — — — — — — — WB2225BQR QR22B225L

1-Phase, 3-Wire SN - 120/240 Volts AC - Enclosure Only

60 2

E0204ML1060Sbd QP, QPH, or HQP

100,000f 5 9.9 5.2 2.7

W0204ML1060bd QP, QPH, or HQP

100,000f 5 8.1 5.5 3.5E0204ML1060Fbd — —

LC002GSb MP-T, MP-HT, or MP-MT LW002GRb MP-T, MP-HT,

or MP-MT

125 2E0204ML1125SCUc

QP or QPH 22,000 1 17.3 7.3 4.3

W0204ML1125CUc QP or QPH 22,000 1 17.2 7.3 4.3E0204ML1125FCUc — —

LC002HS MP-T or MP-HT LW002HR MP-T or MP-HT

200 2— — — — — — — W0202ML1200CU QN, QNH, or

HQN 65,000 1 19.8 8.7 5

LC004VS MD-T, MD-HT, or MD-MT 65,000 1 17.3 7.3 4.3 LW004VR MD-T, MD-HT,

or MD-MT

2251-4 — — — — — — — W0406ML1225CU QPP or QP 10,000 1 23.2 10.4 4.5

2 — — — — — — — QR2N3R2 QR2, QRH2, or HQR2 65,000 1 26.9 7.1 4.4

250 2QR2N1S QR2, QRH2,

HQR2, or HQR2H 100,000 1 31.4 9.6 5.6— — — — — — —

QR2N1F — — — — — — —

3-Phase, 3-Wire 240 Volts AC or 3-Phase, 4-Wire SN — 120/208 Volts AC, 120/240, 240 Volts AC - Enclosure Only

100 2-3E0303ML3100Se QP or QPH

22,000 1 17.3 7.3 4.3W0303ML3100e QP or QPH

22,000 1 17.2 7.3 4.3LP003CSe MP-T or MP-HT LW903CRe MP-T or MP-HTEB3100Se BQ or BQH WB3100e BQ or BQH

250 2-3QR2N1S QR2, QRH2,

HQR2, or HQR2H

100,000 1 31.4 9.6 5.6QR2N3R3 QR2, QRH2,

HQR2, or HQR2H 100,000 1 31.4 9.6 5.6

QR2N1F — — — — — — —

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-21

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

Featuresn For use in home renovations

with existing load centersa

n Suitable for use in indoor Type 1 Enclosure

n Interior, Flush Cover, and Hardware included

n Adjustable depth

n Incoming lugs: 2/0 - #4 AWG

n UL listed

Revised on 03/31/19

Amp Rating

No. of Spaces

No. of Circuits Catalog Numbers

Min. Enclosure Size (inches) Max. Enclosure Size (inches) Cover Dimensions (inches)

L W Db L W Db L W

100 8 16 RE0816ML1100J 13.00 10.50 3.75 19.00 14.25 6.00 22.00 18.00

100 8 16 RE0816ML1100K 20.00 10.50 3.75 26.00 14.25 6.00 29.00 18.00

125 12 24 RE1224ML1125J 17.00 12.25 3.75 21.00 14.25 6.00 23.00 18.00

125 12 24 RE1224ML1125K 22.00 12.25 3.75 26.00 14.25 6.00 29.00 18.00

a Existing enclosure must mearsure within listed dimensions for the use of the kit.

b Depth of enclosure is measured from finished wall surface.

Renovation Interiors1 Phase, 3 WIRE, 120/240V�

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-22

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

a UL Recognized Components.b The letters “CU” in any catalog number represent copper

bus bars.

c Feed thru lugs provided.d Convertible to main breaker using the MBK main breaker

kits.

I1224L1125CU

I0816ML1125CU

W

H

I0408ML1125

W

H

Parallel Lug

W

H

I0202L1200

W

H

1 Phase

W

H

3 Phase

W

H

I1220L1200CT

W

H

3Ø: Main Lug Interiorsb

Amps Catalog Number Spaces Circuits

Dimensions

Height Width125 SI1224L3125B 12 24 10.04 9.95200 SI1224L3200B 12 24 10.04 9.95200 SI2442L3200B 24 42 16.04 9.95200 SI3054L3200B 30 54 19.04 9.95225 SI4242L3225B 42 42 25.04 9.95125 PI1224L3125CUB 12 24 10.04 9.95200 PI1224L3200CUB 12 24 10.04 9.95200 PI1836L3200CUB 18 36 13.04 9.95125 PI1836L3125CUB 18 36 13.04 9.95200 PI2442L3200CUB 24 42 10.04 9.95200 PI3054L3200CUB 30 54 19.04 9.95225 PI4242L3225CUB 42 42 25.04 9.95

1Ø: High Circuit Main Lug Interiors with Neutral Barsd

Amps Catalog Numberb Spaces Circuits

Dimensions

Height Width125 I1224L1125CU 12 24 10.80 9.80125 I1624L1125CU 16 24 12.80 9.80125 I3040L1125CU 30 40 20.80 9.80200 I0816L1200CTd 8 16 10.80 9.80200 I1224L1200CU 12 24 10.80 9.80200 I1632L1200CU 16 32 12.80 9.80200 I2040L1200CU 20 40 14.80 9.80200 I3040L1200CU 30 40 14.80 9.80200 I4040L1200CU 40 40 24.80 9.80225 I4242L1225CU 42 42 26.80 9.80

1Ø: Small Circuit Main Lug Interiors

Amps Catalog Numberb Spaces Circuits

Dimensions

Height Width60 I0204ML1125CU 2 2 4.40 1.8560 I0303ML3100CU 3 3 5.77 3.42125 I0408ML1125 4 8 4.51 6.61125 I0816ML1125CU 8 16 6.19 6.81125 I0816ML1125CUSP 8 16 6.19 6.81200 I0202L1200 4 4 3.88 7.13200 I1220L1200CT 12 20 9.00 7.00

1Ø: Parallel Lug Interiors with Neutral Bars

Amps Catalog Numberb Spaces Circuits

Dimensions

Height Width

200 CTI2040L1200CU 20 40 14.80 9.80200 CTI2440L1200CU 24 40 16.80 9.80200 CTI3040L1200CU 30 40 20.80 9.80

Lug DataInterior Amperage Wire range TorqueI0204ML1060 60 2/0 - 4 AWG 45 lb. - ins.I0303ML3100 100 2/0 - 4 AWG 45 lb. - ins.I1224ML1100 100 2/0 - 4 AWG 45 lb. - ins.I0408ML1125 125 2/0 - 4 AWG 45 lb. - ins.I0816ML1125CU/CUSP 60 2/0 - 4 AWG 45 lb. - ins.Single Phase 125 2/0 - 4 AWG 110 lb. - ins.Single Phase 200/225 300 kcmil - 4 AWG 250 lb. - ins.Three Phase 125 300 kcmil - 6 AWG 340 lb. - ins.Three Phase 200/225 300 kcmil - 6 AWG 340 lb. - ins.

Load CentersLoad Center OEM Interiorsa

Product Category RESI

W

H

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-23

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

Load CentersLoad Center Accessoriesa

Catalog Number Description

Pack Qty

Ground Bar Kits (For ES and PL Load Centers)EC1GB8 GROUND BAR KIT-8 POS 1EC1GB82 GROUND BAR KIT-8 POS, 2/0 LUG 1EC2GB12 GROUND BAR KIT-12 POS 1EC2GB122 GROUND BAR KIT-12 POS, 2/0 LUG 1EC2GB15 GROUND BAR KIT-15 POS 1EC2GB152 GROUND BAR KIT-15 POS, 2/0 LUG 1EC3GB21 GROUND BAR KIT-21 POS 1EC3GB212 GROUND BAR KIT-21 POS, 2/0 LUG 1EC3GB27 GROUND BAR KIT-27 POS 1EC3GB272 GROUND BAR KIT-27 POS, 2/0 LUG 1EC3GB30 GROUND BAR KIT-30 POS 1EC3GB302 GROUND BAR KIT-30 POS, 2/0 LUG 1EC3GB352 GROUND BAR KIT-35 POS, 2/0 LUG 1EC3GB352G GROUND BAR KIT-35 POS, 2/0 LUGb 1

Ground Bar Kits (For Legacy Load Centers)ECGB5 GROUND BAR KIT-5 POS 1ECGB10 GROUND BAR KIT-10 POS 1ECGB101 GROUND BAR KIT-10 POS, 1/0 LUG 1ECGB14 GROUND BAR KIT-14 POS 1ECGB141 GROUND BAR KIT-14 POS, 1/0 LUG 1ECGB142 GROUND BAR KIT-14 POS, 2/0 LUG 1ECGB20 GROUND BAR KIT-20 POS 1ECGB201 GROUND BAR KIT-20 POS, 1/0 LUG 1ECGB202 GROUND BAR KIT-20 POS, 2/0 LUG 1ECINSGB5 INSULATED GROUND BAR KIT-5 POS 1ECINSGB14 INSULATED GROUND BAR KIT-14 POS 1ECINSGB20 INSULATED GROUND BAR KIT-20 POS 1

a The pack quantity is the number that is sold in a pack. Items listed on this page must be ordered in multiples of pack quantities but items are priced per each. For example, ECRLK250 come 3 to a pack so must be ordered in multiples of 3 but pricing would be individual unit price times 3.

b Bar has green-colored screws.c QR Main Breaker Kits include a QR filler plate.d Main Breaker Kits include line terminal barriers.

Revised on 03/31/19

Catalog Number Description

Pack Qty

Load Center Conversion Kitscd

MBK100A MAIN BREAKER KIT 100A 1PH 22K 1MBK125A MAIN BREAKER KIT 125A 1PH 22K 1MBK150A MAIN BREAKER KIT 150A 1PH 22K 1MBK200A MAIN BREAKER KIT 200A 1PH 22K 1MBK225A MAIN BREAKER KIT 225A 1PH 22K 1MBK3100 MAIN BREAKER KIT 100A 3PH QP 240V 10K 1MBK3125R MAIN BREAKER KIT 125A 3PH 240V 10K, QR 1MBK3150R MAIN BREAKER KIT 150A 3PH 240V 10K, QR 1MBK3175R MAIN BREAKER KIT 175A 3PH 240V 10K, QR 1MBK3200R MAIN BREAKER KIT 200A 3PH 240V 10K, QR 1MBK3225R MAIN BREAKER KIT 225A 3PH 240V 10K, QR 1MBK3125HR MAIN BREAKER KIT 125A 3PH 240V 22K, QR 1MBK3150HR MAIN BREAKER KIT 150A 3PH 240V 22K, QR 1MBK3175HR MAIN BREAKER KIT 175A 3PH 240V 22K, QR 1MBK3200HR MAIN BREAKER KIT 200A 3PH 240V 22K, QR 1MBK3225HR MAIN BREAKER KIT 225A 3PH 240V 22K, QR 1MBK3125HHR MAIN BREAKER KIT 125A 3PH 240V 65K, QR 1MBK3150HHR MAIN BREAKER KIT 150A 3PH 240V 65K, QR 1MBK3175HHR MAIN BREAKER KIT 175A 3PH 240V 65K, QR 1MBK3200HHR MAIN BREAKER KIT 200A 3PH 240V 65K, QR 1MBK3225HHR MAIN BREAKER KIT 225A 3PH 240V 65K, QR 1HMBK3125HR MAIN BREAKER KIT 125A 3PH 240V 100K, QR 1HMBK3150HR MAIN BREAKER KIT 150A 3PH 240V 100K, QR 1HMBK3175HR MAIN BREAKER KIT 175A 3PH 240V 100K, QR 1HMBK3200HR MAIN BREAKER KIT 200A 3PH 240V 100K, QR 1HMBK3225HR MAIN BREAKER KIT 225A 3PH 240V 100K, QR 1ECMLK125 1 PH MAIN LUG CONVERSION KIT 100-125A 1ECMLK225 1 PH MAIN LUG CONVERSION KIT 150-225A 1ECMLK3125 3 PH MAIN LUG CONVERSION KIT 100-125A 1ECMLK3225 3 PH MAIN LUG CONVERSION KIT 150-225A 1

Lug KitsECCS1 COLLAR STRAP FOR GRD BARS #14-1/0 1ECCS2 COLLAR STRAP FOR GRD BARS #6-250 1ECLKB1 NEUTRAL LUG KIT WITH BOND TAB 1ECLK3 NEUTRAL LUG KIT #1-300 FOR EQIII LC 1ECLK1-2 NEURTAL LUG KIT #2 TO 1/0 FOR EQIII LC 1ECLK2 NEUTRAL LUG KIT #4-2/0 FOR EQIII LC, PL, ES 1ECLK2SC 2/0 LUG FOR 125AMP NEUTRAL FEEDER 1ECLK2125 125A SUB FEED LUGS-USES 2 SPACES 1ECLK2225 150A-225A SUB FEED LUGS-USES 4 SPACES 1ECLK3225 3P SUB FEED LUGS-USES 6 SPACES 1ECRLK250 RISER LUG KIT 250 KCMIL 3

Miscellaneous Load Center AccessoriesECCP1 PKG OF 100 CIRCUIT DIRECTORY 100ECQF3 QP/BQ/ED2 FILLER PLATE 5ECMBF125 1 PH 100&125A MAIN BREAKER FILLER PLATE 1EC3PMFP1 3 POLE MAIN FILLER PLATE, QJ 1EC3PMFPR 3 POLE MAIN FILLER PLATE, QR 1ECSMK1 SURFACE MOUNT 1/4" SPACE KIT FOR LC'S 4ECTS2 LC TRIM SCREWS 6ECTS2W LC TRIM SCREWS WHITE 6ECLCHINGE GREY LC HINGES 100ECADHLCDIRLBL ADHESIVE LC DIRECTORY LABELS 100ECSIELATCH SIEMENS LC LATCHES 25ECBONDSCRW LC BOND SCREW 10ECSN1 SCREWS & NUTS FOR HC HUB-BOTTOM USE 4RAG24 RISER AUX GUTTER 24" 1ECAFL ARC FLASH LABEL 10

Neutral Bar KitsECLNB14 MLO NEUTRAL BAR KIT-14 POS 1ECCNB16 CONVERTIBLE LC NEUTRAL BAR KIT-16 POS 1ECMLK125 1 PH MAIN LUG CONVERSION KIT 100-125A 1

Lock KitsECQFL2 FLUSH LOCK KIT FOR ULT., PL, ES, 3PH

100A-225A 1

ECQFL1 FLUSH LOCK KIT-REPLACEMENT FOR EQ LC 1

ECQFL3 ADD-A-LOCK (FLUSH LOCK ) FOR 300-400A LC 1

HubsECHA000

HA Type W0204ML1060

CLOSURE PLATE 1

ECHA075 HUB - 3/4” 1

ECHA100 HUB - 1” 1

ECHA125 HUB - 1 1/4” 1

ECHA150 HUB - 1 1/2” 1

ECHS000

HS Type PL & ES and Small Circuit Loadcenters

CLOSURE PLATE 1

ECHS075 HUB - 3/4” 1

ECHS100 HUB - 1” 1

ECHS125 HUB - 1 1/4” 1

ECHS150 HUB - 1 1/2” 1

ECHS200 HUB - 2” 1

ECHS250 HUB - 2 1/2” 1

ECHV000

HV Type 300-400A Loadcenters

CLOSURE PLATE 1

ECHV200 HUB - 2” 1

ECHV250 HUB - 2.5” 1

ECHV300 HUB 3” 1

ECHV350 HUB - 3.5” 1

ECHV400 HUB - 4” 1

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-24

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

Ground Bar Kit, ECGB14 Neutral Lug Kit, ECLK1-2wire range — #2-1 AWG

Cu or Al

Neutral Lug Kit, ECLK3wire range — #1-300 MCM

Neutral Lug Kit, ECLK2wire range — #4-#2/0 AWG

Cu or Al

For use on Ground Bar onlyCollar Strap, Wire Range;

ECCS1; ECCS2

2 PH Main Lug Conversion Kit150A-225AECMLK225

3-Pole Main Breaker KitMBK3200

Ground Bar Kit20 POS. 2/0 Lug

ECGB202

Main Breaker Retainer kit for PL, ES, & Ultimate Load Centers

ECMBR2

Main Breaker Retainer Kit for EQ Load Centers

ECMBR1

Add-A-Lock(Flush Lock), ECQFL3

300-400A Load Centers

Add-A-Lock(Flush Lock), ECQFL2

PL, ES, Ultimate Load Centersand EQ III up to 225A

Filler Plate, ECQF3Add-A-Lock(Flush Lock) ECQFL1For EQ load centers

Main Breaker Kit200A - 225A, 1PH 22K

MBK200A

Lug Kit, 3-Pole, Subfeed orFeed thru Applications

ECLK3225

Load CentersLoad Center Accessories

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-25

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

Load CentersLoad Center Accessories­

Load centers and meter combosTouchsafe barriers are required for any single main serviceentrance application for a panel covered under UL 67. LineTerminal Barriers will be included in Main Breaker LoadCenters and Single Main Meter Combos manufactured afterJanuary 1, 2017.

Single phase and 3-phase main breaker kits will include abarrier. Field installable kits are being created for replacementsif needed and line terminal barriers are being added to holddown kits that can be used in back-fed applications. Thebarriers are designed to have minimal interference duringload center installation, and can be removed and reattachedas necessary.

Catalog number Description

ECLTB1 For EQ Main Breakers/MBK kits 100A-125A

ECLTB2 For EQ Main Breakers/MBK kits 150A-225A

ECLTB3 For QN / QNR type breakers

ECLTB4 For QR 3 phase breakers

ECMBR1a For 2 Pole QP / MP-T type breakers for EQIII (extruded basepan) and Line 5 Load Centers

ECMBR2a For 2 Pole QP / MP-T type breakers to be used with Ultimate LCs (now ES / PL), Murray or Rock Solid

ECMBR3 For 3 Pole QP / MP-T type breakers to be used with PL, ES 3 phase load centers

ECLX387HD For 2 Pole MP-T type breakers in legacy Murray load centers

Revised on 03/31/19

a Barrier fits with 2-pole QP 70A and above and all amperages of QPH and HQP.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-26

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

To activate standby power the utility main breaker must be in the “OFF” position to prevent dangerous feedback between the power sources.

Panels in which the bussing or wire forms from the meter socket land on main lugs are not acceptable for use in standby systems because turning the main breaker to “OFF” does not prevent feedback to the utility power lines. Examples of such panels include catalog numbers that start with the following letters.

MC0606L1200*

MM0406L1*

MC1212L1200*

Standard featuresn UL listed for use in most

Siemens load centers and meter combinations

n Suitable for use with optional standby systems in accordance with article 702 of the National Electric Code

n Corrosion resistant finish

n Easy assembly requiring no modifications to the load center or meter combination

n Remains attached to the main breakers when load center cover

Wire formsor bussing

Acceptable usage of Interlock Kits by load center/meter combination catalog numbers

Siemens Meter CombinationsMC0408B1200RGA 8 MC1020B1100S 1 2

MC0408B1200RT 8 MC1224B1100EFC 2

MC0408B1200T 8 MC1224B1100ESC 2

MC0816B1150JLT 9 MC1224B1125EFC 2

MC0816B1150RCT 8 MC1224B1125ESC 2

MC0816B1150TH 5 7 MC2040B1150JLC 8

MC0816B1200CT 8 MC2040B1200JLC 8

MC0816B1200EFN 2 MC2040B1200R 5 7

MC0816B1200ESN 2 MC2040B1200RC 9

MC0816B1200EST 2 MC2040B1200RJBC 9

MC0816B1200JLT 9 MC2442S1200FC 2

MC0816B1200RCT 8 MC2442S1200SC 2

MC0816B1200RGA 8 MC3042B1200FED 3

MC0816B1200RTH 5 7 MC3042B1200JLC 8

MC0816B1200T 7 MC3042B1400FD 5 7

MC0816B1200TH 5 7 MC3042B1400SC 5 7

MC0816B1350RLTM 5 MC3042B1400SCS 5 7

MC0816B1400RLTM 5 MC3042B1400SD 5 7

MC0816B1400SCS 5 7 MC3042B1400SDS 5 7

MC1020B1100F 1 2 MC4040S1200SC 5

Numbers 1 through 9 in these tables representthe last digit in each interlock kit catalog number.Example: 1 = ECSBPK01

When used in horizontal positions as typical inmost load centers, ECSBPK07 is recommended foruse only with QNR type circuit breakers.

Standby power interlock kits are not intended for use with AFCI, GFCI, 3-pole or 1/2” frame circuit breakers and 4 space, 125 amp load centers.

Siemens type EQ load centers using a “4-pole” main breaker do not have a kit available to interlock this main to branch circuits. Branch circuit positions can be interlocked.

Utility main breakerStandby power main breaker

Convert load centers or meter combinations into standby power panels

ES Series Load Centers can utilize interlock kits: 1, 2, 5, 6, 7. Kits 3 and 4 can also be used on main breaker panels.

PL Series Load Centers can utilize interlock kits: 1, 2, 3, 4, 5, 6, 7.

Load CentersManual Transfer Interlock Kits for Load Centers and Meter Combinations

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-27

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

Load CentersManual Transfer Interlock Kits for Load Centers and Meter Combinations

Prevents dangerous feedback between two sources of power

a Manual breaker interlock kits are attached to the break-ers not the trim of the load center.

b These kits take up 2 spaces adjacent to the 2 pole breaker being interlocked. Those spaces cannot accommodate filler plates.

Manual Transfer Interlock Kitsa

Catalognumber

UsageInformation

Utility mainbreaker types

Standby mainbreaker types

InterlockNumber

ECSBPK01 For use on load centers or meter combinations that will accept 2-pole circuit breakers oppositeone another as shown.

QP, QPH, HQPH QP, QPH, HQPH 1

ECSBPK02 For use on load centers or meter combinations that will accept 2- or 4-pole next to a 2-pole circuit breaker side by side as shown.

QP, QPH, HQPH QP, QPH, HQPH 2

ECSBPK03b For use on UltimateTM and RockSolid load centers, 150 amp andhigher, to connect the main breakerto a 2-pole circuit breaker.

MBK150A,MBK200A, OR MBK225A

QP, QPH, HQPH 3

ECSBPK04b For use on Ultimate and Rock Solidload centers, 125 amp and lower,to connect the main breaker to a 2-pole circuit breaker.

MBK100A orMBK125A

QP, QPH, HQPH 4

ECSBPK05 For use on load centers or meter meter combinations that will accept a QNR (MD-TR) frame circuit breaker next to a 2-pole circuit breaker as shown.

QNR, QNRH, HQNR QP, QPH, HQPH 5

ECSBPK06b For use on load centers or meter combinations that will accept a QN (MD-T) frame circuit breaker next to a 2-pole circuit breaker as shown.

QN, QNH, HQN QP, QPH, HQPH 6

ECSBPK07 For use on load centers or meter combinations that will accept two QNR (MD--TR) circuit breakers side by side as shown OR will accept two QN (MD--T) circuit breakers side by side as shown.

QNR, QNRH, HQNR, QN, QNH, HQN

QNR, QNRH, HQNR QN,QNH, HQN

7

ECSBPK08b For use on 8 space, over/under,OH/UG feed meter combinations as shown. Limited application to specific catalog numbers.

QPP, QPPH QP, QPH, HQPH 8

ECSBPK09b For use on 20 space, over/under, OH/UG feed meter combinations as shown. Limited application to specific catalog numbers.

QPP, QPPH QP, QPH, HQPH 9

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-28

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

Load Centers1-Phase Indoor and 1-Phase & 3-Phase Outdoor Enclosures—Knockout Diagrams

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-29

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

Siemens­/­Speedfax­ Previous­folio:­1-17

Load Centers3-Phase Indoor and Riser Enclosures—Knockout Diagrams

(8) K.O.s for1", 1-1/4", 1-1/2", 2", 2-1/2"

Conduit

(2) K.O.s for1-1/2", 2", 2-1/2" Conduit

(42) for 1/2" ConduitK.O.s

(8) for1/2", 3/4" Conduit

K.O.s

(10) for1/2", 3/4", 1" Conduit

K.O.s

(4) 5/16" K.O.s

New Riser Panel KO Diagram

6/17/08

RAG24 KO Dwg1/5/11

(4) K.O.s for1-1/2", 2", 2-1/2"Conduit

(4) Mounting Holes

All Riser Panels RAG24

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-30

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

Siemens­/­Speedfax­ Previous­folio:­1-18

Load CentersOutdoor Enclosures—Knockout Diagrams

Outdoor 400ALoad Center

2 Type "HV" Hub Openings

12 K.O.'s For.5", .75", Conduit

2 K.O.'s For2.50", 3", 3.50" Conduit

2 K.O.'s For.75", 1", 1.25", 1.50" Conduit

5 K.O.'s For1", 1.25", 1.50", 2", 2.50" Conduit

4 Mounting Holes.218 Dia

4 K.O.'s For.5", .75", 1", 1.25" Conduit

W0204ML1060 W0408ML1125

W0406ML1125CU

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-31

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

W0204ML1125

W0303ML3100

WB3100

WB2225 and WB32225

W0612ML1125

W0816ML1125

Load CentersOutdoor Enclosures—Knockout Diagrams

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-32

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

E0612ML1125

E0816ML1125

E1224ML1100F

E0408ML1125 E0303ML3100SCU

EB3100

E0204ML1060

Indoor 300-400ALoad Center

24 K.O.'s For.5", .75"Conduit

8 K.O.'s For.5", .75", 1",

1.25" Conduit

E0204ML1060

E0408ML1125E0303ML3100SCU

EB3100

E0612ML1125

E0816ML1125

E1224ML1100F

Load CentersIndoor Enclosures—Knockout Diagrams

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-33

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

Ultimate Load Center Cross Reference to ES Series and PL SeriesPhase Type Current Sku ES Series PL Series

1 Phase Indoor

New — P3040L1200SGNew — P4040L1200SGNew - Higher Circuits — P4260L1225CUSGNew - Higher Circuits S3054L1200 P3054L1200CUNew - Higher Circuits S5470B1225 P5470B1225CUNew - Higher Circuits S5470L1225 P5470L1225CUNew - Higher Circuits SW3054L1200 PW3054L1200CUG1212L1125 S1212L1125 -G1212L1125CU — P1212L1125CUG1224B1100 S1224B1100 -G1224B1100CU — P1224B1100CUG1224L1125 S1224L1125 -G1224L1125CU — P1224L1125CUG1224L1125CUSG — P1224L1125CUSGG1224L1200CU S1224L1200 P1224L1200CUG1624B1100 S1624B1100 -G1624B1100CU — P1624B1100CUG1624B1100W S1624B1100W -G1624L1125 S1624L1125 -G1624L1125CU — P1624L1125CUG1624L1125CUSG — P1624L1125CUSGG1630B1150 S1630B1150 -G2020B1100 S2020B1100 -G2020B1100CP S2020B1100P -G2020B1100CU — P2020B1100CUG2020L1125 S2020L1125 -G2020L1125CU — P2020L1125CUG2020L1125CUW S2020L1125W —G2030B1150 S2030B1150 —G2030B1150CU — P2030B1150CUG2030L1125CUSG — P2030L1125CUSGG2030L1150 S2030L1150 —G2030L1150CU — P2030L1150CUG2030L1150CUSG — P2030L1150CUSGG2040B1200 S2040B1200 —G2040B1200CU — P2040B1200CUG2040L1200 S2040L1200 —G2040L1200CU — P2040L1200CUG2424B1100CU — P2424B1100CUG2424B1125 S2424B1125 —G2424L1125 S2424L1125 —G2424L1125W S2424L1125W —G2430B1150 S2430B1150 —G2430L1125CUSG — P2430L1125CUSGG2440B1200 S2440B1200 —G2440L1125CU S2440L1125 P2440L1125CUG2440L1200 S2440L1200 —G2440L1200CU — P2440L1200CUG3030B1100CU S3030B1100 P3030B1100CUG3030B1150 S3030B1150 —G3030B1150CU — P3030B1150CUG3030L1200 S3030L1200 —G3030L1200CU — P3030L1200CUG3030L1200W S3030L1200W —G3040B1200 S3040B1200 P3040B1200G3040B1200CP S3040B1200P —G3040B1200CU — P3040B1200CUG3040L1125CU — P3040L1125CUG3040L1125CUW S3040L1125W —G3040L1200 S3040L1200 P3040L1200G3040L1200CP S3040L1200P —G3040L1200CU — P3040L1200CUG3040L1200CUSG — P3040L1200CUSGG4040B1200 S4040B1200 P4040B1200G4040B1200CP S4040B1200P —G4040B1200CU — P4040B1200CUG4040B1200W S4040B1200W P4040B1200WG4040L1125CU S4040L1125 P4040L1125CUG4040L1200 S4040L1200 P4040L1200G4040L1200CU — P4040L1200CUG4040L1200CUSG — P4040L1200CUSGG4242B1225CU S4260B1225 P4260B1225CUG4242L1225CU S4260L1225 P4260L1225CUG2020B1100SP S2024B1100 P2024B1100CUG2020L1125SP S2020L1125G —G2024L1125SP S2024L1125/S2024L1125G P2024L1125CUG2424L1125SP S2424L1125G —G3030B1125CU S3030B1125 P3030B1125CUG3040L1125 S3040L1125/S3040L1125G —G4040B1200CUSG — P4040B1200CUSG

Load CentersCross Reference

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-34

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

Ultimate Load Center Cross Reference to ES Series and PL SeriesPhase Type Current Sku ES Series PL Series

1 Phase Outdoor

W0816B1200CT SW0816B1200T PW0816B1200TCW0816L1200CT SW0816L1200T PW0816L1200TCW1212L1125CU SW1212L1125 PW1212L1125CUW1224B1100CU SW1224B1100 PW1224B1100CUW1224L1125CU SW1224L1125 PW1224L1125CUW1224L1200CU SW1224L1200 PW1224L1200CUW1224L1225CU SW1224L1225 PW1224L1225CUW1624B1100CU SW1624B1100 PW1624B1100CUW1624L1125CU SW1624L1125 PW1624L1125CUW2020B1100CU SW2020B1100 PW2020B1100CUW2030L1150CU SW2030L1150 PW2030L1150CUW2040B1200CU SW2040B1200 PW2040B1200CUW2040L1200CU SW2040L1200 PW2040L1200CUW2424L1125CU SW2424L1125 —W3040B1200CU SW3040B1200 PW3040B1200CUW3040L1125CU SW3040L1125 PW3040L1125CUW3040L1200CU SW3040L1200 PW3040L1200CUW4040B1200CU SW4040B1200 PW4040B1200CUW4040L1200CU SW4040L1200 PW4040L1200CUW4242B1225CU SW4260B1225 PW4260B1225CUW4242L1225CU SW4260L1225 PW4260L1225CU

3 Phase

Indoor

New S4242B3150 —New – Higher Circuits — P5470B3225CUNew – Higher Circuits S5470L3225 P5470L3225CUG1224L3125CU S1224L3125 P1224L3125CUG1224L3200CU S1224L3200 —G1836L3150CU S1836L3150 —G2442B3150CU S2442B3150 P2442B3150CUG2442B3150CU22 — P2442B3150CUG2442L3150CU S2442L3150 —G2442L3200CU S2442L3200 P2442L3200CUG3030B3100CU S3030B3100 P3042B3100CUG3030B3100CU22 — P3042B3100CUG3042B3200CU S3054B3200 P3054B3200CUG3042L3200CU S3054L3200 P3054L3200CUG4242B3200CU S4260B3200 P4260B3200CU

G4242B3225CU S4242B3225 P4260B3225TCU/P4260B3225CU

G4242L3225CU S4260L3225 P4260L3225CU

Outdoor

W1224L3125CU SW1224L3125 PW1224L3125CUW1224L3200CU SW1224L3200 —W1836L3150CU SW1836L3150 —W2442B3150CU SW2442B3150 —W2442L3150CU SW2442L3150 —W2442L3200CU SW2442L3200 PW2442L3200CUW3042B3200CU SW3054B3200 PW3054B3200CUW3042B3200CU22 — PW3054B3200CUW3042L3200CU SW3054L3200 PW3054L3200CUW4242B3200CU SW4260B3200 PW4260B3200CUW4242B3200CU22 — PW4260B3200CUW4242B3225CU SW4242B3225 PW4260L3225CUW4242L3225CU SW4260L3225 —

Load CentersCross Reference

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-35

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

Product Category RESI

Circuit BreakersArc-Fault and Ground-Fault Breakers Selection/Wiring�Diagrams

n Built to order. Allow 8 -10 weeks for delivery.a UL Listed as SWD (Switching Duty) Rated, suitable for 120V AC Fluorescent Lighting.b Add WG to the part number for the WireGuide version.

Arc-Fault Circuit Interrupters (AFCI)AFCI’s detect arcing faults (an unintentional arcing condition in a circuit) that standard circuit breakers are unable to detect. The device is intended to mitigate the effects of arcing faults by functioning to de-energize the circuit when an arc-fault is detected.

1-Pole Equipment Protection

2-Pole Equipment Protection

1-Pole GFCI 2-Pole GFCI

1-Pole Combination Type AFCI

2-Pole Combination Type AFCI

Wiring Diagrams

QAF2/QPF/QE/QPF2 Accessories

Combination Type AFCIDetects all three possible types of arc faults: line-to-ground, line-to-neutral, and series.Breaker Type

Ampere Rating

10,000 A IR Catalog No.

22,000 A IR Catalog No.

65,000 A IR Catalog No.

QAF2/QAFH2/HQAF21-Pole 120V AC

1520

QA115AFC a b

QA120AFC a b

QA115AFCH a

QA120AFCH a

QA115AFCHHn a

QA120AFCHHn a

QAF/QAFH2-Pole 120/240V AC

1520

Q215AFC a b

Q220AFC a b

Q215AFCHn a

Q220AFCHn a

——

Branch-Feeder AFCIDetects line-to-ground and line-to neutral arcs.

QAF2/QAFH2/HQAF21-Pole 120V AC

15 20

QA115AF a

QA120AF a

QA115AFHn a

QA120AFHn a

QA115AFHHn a

QA120AFHHn a

NEW Dual Function AFCI/GFCIThe Dual Function Circuit Breaker combines Combination Type AFCI and GFCI, protecting against both Arc Faults and (5mA) Ground Faults. The device includes the Self Test feature, making it the first in class in electrical safety for homeowners.

QFGA2/QFGAH2/HQFGA21-Pole 120V AC

15 20

Q115DF a b

Q120DF a b

Q115DFHn a

Q120DFH a

Q115DFHHn a

Q120DFHHn a

Description Catalog Numbera

Padlocking Device 1-Pole ECPLD1

Padlocking Device 2-Pole ECPLD2

Handle Block ECBX231M

1-Pole Branch Feeder AFCI

1-Pole Dual Function AFCI/GFC

Ground-Fault Circuit Interrupters (GFCI)Provides Class A (5mA) ground fault protection. Intended for personnel protection. Includes Self Test as an added safety feature.

Breaker TypeAmp Rating

10,000 A IR Catalog No.

22,000 A IR Catalog No.

65,000 A IR Catalog No.

QPF2/QPHF2/HQPF21-Pole 120V AC Plug-in

152030

QF115Aab

QF120Aab

QF130Aa

QF115AHna

QF120AHna

QF130AHna

QF115AHHna

QF120AHHna

QF130AHHna

QPF/QPHF 2-Pole 120/240V AC Plug-in

152030405060

QF215AQF220AQF230AQF240AQF250AQF260A

QF215AHn

QF220AHn

QF230AHn

QF240AHn

QF250AHn

QF260AHn

— — — — — —

Ground Fault Equipment Protection (30mA)Provides protection of equipment from damaging line-to-ground faults currents. De-energizes the circuit for all ungrounded conductors of the circuit.

QE/QEH1-Pole 120V AC Plug-in

15 20 30

QE115QE120QE130

QE115Hn

QE120Hn

QE130Hn

— — —

QE/QEH2-Pole 120/240V AC Plug-in

15 20 30 40 50 60

QE215QE220QE230QE240QE250QE260

QE215Hn

QE220Hn

QE230Hn

QE240Hn

QE250Hn

QE260Hn

— — — — — —

• UL Listed • HACR Rated

Revised on 05/31/18

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-36

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

1-Pole Dual FunctionCircuit Breaker

Two state-of-the-art technologies combined in one device!Dual Function Circuit Breakers: QFGA2/QFGAH2/HQFGA2

Introducing the Dual Function Circuit Breaker that provides Arc Fault and Ground Fault protection in one device. The 2014 National Electric Code requires Arc Fault protection on Kitchen and Laundry circuits where Ground fault protection is currently a requirement. One solution to meet this code is to pair an AFCI circuit breaker with a GFCI receptacle. The Dual function breaker will replace the Arc fault breaker and the Ground Fault receptacle. Additionally, the breaker will help eliminate the use of two separate devices and improve cost savings.

Features• Plug-in or bolt-on branch circuit breakers for

Siemens single phase load centers

• Self Test feature as required by UL 1699 effective June 2015

• Saving time – ease of installation – only One product to install vs. Two

• Saving money – Two safety devices combined into One.

• LED trip indicator – a Siemens exclusive!

• Available with interrupting rating of 10kA, 22kA or 65kA

• UL Listed

• Torque rating: 25 lb. in.

• Padlocking device available, use catalog number ECPLD1

• Both lugs at the same angle - for easier wiring

Circuit BreakersDual Function Arc-Fault and Ground-Fault breaker

Revised on 05/31/18

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-37

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

QP / QPH / HQP Internal AccessoriesControl Voltage AC Catalog Number Field/Factory Installed120V Shunt Trip add suffix …00S01n Factory24V Shunt Trip add suffix …00S07n Factory120V Auxiliary Switch add suffix …01nb Factory

ModificationsDescription Catalog Number400 Hz Calibration add suffix …Yh

Marine 50˚C Ambient add suffix …MCalibrationFungus Proofing add suffix …F

Continuous Current Rating @ 40° C

Type QPa Type QPH Type HQP

10,000A IR 22,000A IR 65,000A IR

Catalog Number Catalog Number Catalog Number

1-Pole Plug-In (120/240V AC)e

10 Q110i — —15 Q115c Q115Hc Q115HHnc

20 Q120c Q120Hc Q120HHnc

25 Q125 Q125Hn Q125HHn

30 Q130 Q130H Q130HHn

35 Q135n Q135Hn Q135HHn

40 Q140 Q140H Q140HHn

45 Q145n Q145Hn Q145HHn

50 Q150 Q150H Q150HHn

60 Q160 Q160Hn Q160HHn

70 Q170 Q170Hn Q170HHn

2-Pole Plug-In (Common-Trip 120/240V AC)f

10 Q210i — —15 Q215 Q215H Q215HH20 Q220 Q220H Q220HH25 Q225 Q225Hn Q225HHn

30 Q230 Q230H Q230HH35 Q235 Q235Hn Q235HHn

40 Q240 Q240H Q240HHn

45 Q245 Q245Hn Q245HHn

50 Q250 Q250H Q250HH60 Q260 Q260H Q260HH70 Q270 Q270H Q270HH80 Q280 Q280Hn Q280HHn

90 Q290 Q290H Q290HHn

100 Q2100 Q2100H Q2100HH110 Q2110 Q2110H Q2110HHn

125 Q2125 Q2125H Q2125HH

2-Pole Plug-In (Common-Trip 240V AC)df

15 Q215R — —20 Q220R — —30 Q230R — —40 Q240R — —50 Q250R — —

3-Pole Plug-In (Common-Trip 240V AC)g

15 Q315 Q315H Q315HHn

20 Q320 Q320H Q320HH25 Q325 Q325Hn Q325HHn

30 Q330 Q330H Q330HH35 Q335 Q335Hn Q335HHn

40 Q340 Q340H Q340HH45 Q345 Q345Hn Q345HHn

50 Q350 Q350H Q350HH60 Q360 Q360H Q360HH70 Q370 Q370H Q370HHn

80 Q380 Q380H Q380HHn

90 Q390 Q390H Q390HHn

100 Q3100 Q3100H Q3100HH

For external accessories please refer to page 1-44.

n Built to order. Allow 2-3 weeks for delivery.a UL Listed for use with 60/75° wire through 40 amps,

UL listed for use with 75° wire only for 50 amps and above, HACR rated.

\b 1A and 1B contacts.

c UL Listed for frequent switching applications (SWD). 120V AC Fluorescent Lighting. d UL Listed for use on 3-phase grounded “B” systems — 10,000 for this application. e Shipped 12 per sleeve.

f Shipped 6 per sleeve.g Shipped 4 per sleeve.h UL Listed 5 KA IR.i Type QP1, UL listed for 16 AWG conductors and

multiple wires.

Circuit BreakersType QP with INSTA-WIRE

Product Category RESI

Q120

Q220

Q320

Revised on 10/31/18

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-38

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

For external accessories, please refer to page 1-44.

Circuit BreakersDuplex, Triplex and Quadplex Plug-In Breakers�

Product Category RESI

QT TriplexThese space saver triplex breakers provide a 2-pole common trip breaker for 120/240V AC circuits and two single poles for 120V AC circuits. Triplex require two panel spaces. HACR rated.

QT QuadplexThese space saver quadplex breakers provide two sets of common trip, two-pole breakers for 120/240V AC circuits, and require two panel spaces. HACR rated.

For inches / millimeters conversion, see Application Data section.

n Built to order. Allow 2–3 weeks for delivery. a Non-CTL. For replacement use only in panels manufac-tured before 1968

Duplex Circuit Breakers

Breaker TypeAmpereRating Catalog Number Catalog Number

QT1-Pole10K AIC120V AC

15–15 Q1515 Q1515NCa

15–20 Q1520 Q1520NCa

20–20 Q2020 Q2020NCa

20–30 Q2030 —30–15n Q3015 —30–20 Q3020 —30–30 Q3030 Q3030NCa

SHIPPING: 12 per carton, (Wt. 4.8 lbs.)

Triplex Circuit Breakers

BreakerType

Ampere Rating

CatalogNumberSingle Pole

Common-Trip2-Pole

QT2-Pole10K AIC120/240V ACInner PolesCommon Trip

15 15 Q21515CT15 20 Q21520CT15 25 Q21525CTn

15 30 Q21530CT15 35 Q21535CTn

15 40 Q21540CT15 45 Q21545CTn

15 50 Q21550CT20 20 Q22020CT20 25 Q22025CTn

20 30 Q22030CT20 35 Q22035CTn

20 40 Q22040CT20 45 Q22045CTn

20 50 Q22050CT30 30 Q23030CTSHIPPING: 6 per carton, (Wt. 4.9 lbs.)

Quadplex Circuit Breakers

BreakerType

Ampere Rating

CatalogNumber

Common-Trip 2-Pole Outside

Common-Trip 2-Pole Inside

QT2-Pole10K AIC120/240V ACInner andOutter 2 PolesCommon Trip

15 15 Q21515CT215 30 Q21530CT220 20 Q22020CT220 50 Q22050CT230 20 Q23020CT230 25 Q23025CT230 30 Q23030CT230 50 Q23050CT240 20 Q24020CT240 30 Q24030CT240 40 Q24040CT2SHIPPING: 6 per carton, (Wt. 4.8 lbs.)

QT DuplexThese space saver duplex breakers combine two independent 1/2" breaker poles in a common unit. This unit plugs into one load center stab and requires one panel space. HACR rated.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-39

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

Circuit BreakersSpecial Application Breakers

Product Category RESI

n Built to order. Allow 2–3 weeks for delivery. Note: All circuit breakers on this page are 10K AIC

a UL Listed as SWD (Switching Duty) Rated, suitable for 120V AC Fluorescent Lighting.

Switching Neutral

Wiring Diagrams

Figure 1 Figure 2

Figure 3 Figure 4

HID LightingFor high-intensity discharge lamp loads having in-rush currents above the instantaneous trip setting of a standard breaker.

BreakerType

WiringDiagram

Complete Breaker UL Unenclosed

Ampere Rating Catalog Number

QP1-Pole120V AC

Figure 115 Q115HIDan

20 Q120HIDa

30 Q130HID

QP2-Pole120/240V AC

Figure 215 Q215HID20 Q220HIDn

30 Q230HIDn

Molded Case Switch For applications that do not require overcurrent protection.

QP1-Pole120V AC

Figure 1 100 Q1100S

QP2-Pole120/240V AC Figure 2

305060125

Q230SQ250SQ260SQ2125S

No-Noise For applications that require a reduction in the 60-cycle hum of a standard breaker.

QP2-Pole120/240V AC

Figure 2 5060

Q250NNnQ260NN

Switching Neutrals Used where all conductors are required to be disconnected. Neutral pole of the circuit breaker does not connect to load center bus. One side is wired to neutral and the other side to the device.

QG2-WireCommon Trip120V AC

Figure 3 1520

QG215QG220

QG3-WireCommon Trip120/240V AC

Figure 4 20 QG320

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-40

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

Circuit Breakers3/4 Inch Plug-In Breakers

Product Category RESI

Number of Number Per Shipping Poles Carton Weight (lbs.)

1 16 3.8 2 8 4.2

Shipping Weights

For inches / millimeters conversion, see Application Data section.

a UL Listed for frequent switching applications (SWD). 120V AC Fluorescent Lighting. One or two load conductors.

Listed Panelboards—Square D—Catalog Numbers

QO2L30F/S QO2-4L70F/S QO2-4L70TS QO2-4L70RB QO6-12L100F/S QO6-12L100DF/S QO6-12L100TF/S QO6-12L100DTF/S QO6-12L100RB QO8-16L100F/S QO8-16L100DF/S QO8-16L100TF/S QO8-16L100DTF/S QO8-16L100RB QO112M100/RB QO116M100/RB QO120M100/RB QO124M100 QO12L100DF/S QO12L100RB QO12-20M100/RB QO12-20M100TF/S

QO12M100/RB QO16-20M100/RB QO16M100/RB QO20M100/RB QO112L125G/RB QO112-24L125G/RB QO112-24L125GWGC QO116L125G QO116-24L125G/RB QO12-24L125/RB QO120-24L125G QO120-24L125GWGC QO120L125G QO124L125G/RB QO124M125/RB QO16L125/RB QO16-12M125FTRB QO16-24L125/RB QO20L125/RB QO20-24L125/RB QO24L125/RB QO120-30L150G

QO120-30M150/RB QO124L150G QO124M150 QO130L150G/RB QO130M150/RB QO16L150/RB QO16M150/RB QO16-30L150/RB QO18-16M150FTRB QO20-30M150/RB QO20-30M150TF/S QO20-30L150 QO24L150/RB QO24M150/RB QO30L150/RB QO30M150/RB QO8-16M200FT/RB QO112L200G/RB QO120-40M200/RB QO120-40M200TC QO124M200 QO130L200G/RB

QO130-40M200 QO130M200/RB QO130-40L200G/RB QO140M200/RB QO16L200/RB QO16M200/RB QO18-16M200FTRB QO20-40L200/RB QO20-40M200TF/S QO20-40M200/RB QO24L200/RB QO24M200/RB QO30L200/RB QO30M200/RB QO30-40L200/RB QO30-40M200/RB QO40M200/RB QO140M225 QO142L225G/RB

Panelboard Compatibility List

Featuresn 3/4" format

n HACR Rated

n UL Classified for use in certain Square D load centers

Type QD Circuit BreakersThe Type QD circuit breaker line is available in 1-pole and 2-pole common trip versions listed on this page.

The circuit breakers are UL Classified and UL Listed.

All QD breakers are supplied with load side connectors suitable for 60/75°C wire and are calibrated for 40°C maximum ambient applications.

UL ClassifiedSiemens Type QD circuit breakers are UL Classified for use in specific Square D load centers in place of Square D Type QO® circuit breakers. A Panelboard Compatibility List packaged with each QD breaker shows which type QD circuit breakers are acceptable for use in Square D load centers.

The interrupting rating on these circuit breakers is 10,000A IR maximum and they are not series rated with Square D circuit breakers or equipment. This UL Classification allows a Siemens Type QD circuit breaker to be used in place of a Square D Type QO circuit breaker in those load centers that are specifically shown on the Panelboard Compatibility list. For additional information, contact your local Siemens sales engineer.

ContinuousCurrent Rating@ 40°C

1-Pole 2-Pole

120V 120/240V Common Trip

Catalog Number Catalog Number

15 D115a D21520 D120a D22030 D130 D23040 D140 D24050 D150 D25060 D160 D260

D120 D220

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-41

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

Requires 4 panel spaces, 2 adjacent and 2 opposite. SHIPPING: 1 per carton (Wt. 3 lbs.)

Requires 6 spaces due to cross over design. Fits only EQIII 125-400A 3-phase load centers

SHIPPING: 5 per carton (Wt. 17 lbs.)

a All circuit breakers on this page are common trip.b Reverse handle.c CSA Listed.d MBK100A for use in 100 and 125A load centers.

MBK125A for use in 125A load centers. MBK150A for use in 150, 200 and 225A load centers. MBK200A for use in 200 and 225A load centers. MBK225A for use in 225A load centers. MBK175A for use in 200 and 225A load centers.

e QNR required for horizontal applications or vertical applications where the lugs are facing up. The QN breaker is required for vertical applications where the lugs are facing down as shown.

For inches / millimeters conversion, see Application Data section.n Built to order. Allow 2–3 weeks for delivery.

BreakerType

AmpereRating

CatalogNumber

CatalogNumber

UL InterruptingRatings (kA)

QN2-Pole120/240V AC

150 QN2150 QN2150Rb 10175 QN2175n QN2175Rbn 10200 QN2200 QN2200Rb 10

QNH2-Pole120/240V AC

150 QN2150H QN2150RHb 22175 QN2175Hn QN2175RHbn 22200 QN2200H QN2200RHb 22

HQN2-Pole120/240V AC

150 HQN2150 HQN2150Rb 65175 HQN2175n — 65200 HQN2200 HQN2200Rb 65

Main Breaker KitsFor use in PL, ES, and Ult Load Centersd For use in EQIII Load Centers

ULType

AmpereRating

CatalogNumber

ULType

AmpereRating

CatalogNumber

UL InterruptingRatings (kA)

EQ8681 100 MBK100A EQ9675 100 MBK100 22EQ8682 125 MBK125A EQ9677 125 MBK125 22EQ8693 150 MBK150A EQ9683 150 MBK150 22— — — EQ9684 175 MBK175n 22EQ8695 200 MBK200A EQ9685 200 MBK200 22EQ8696 225 MBK225A EQ9686 225 MBK225 22

BreakerType

AmpereRating

CatalogNumber

UL InterruptingRatings (kA)

QPJc

3-Pole240V AC

125 QPJ3125 10150 QPJ3150 10200 QPJ3200 10

Breaker Type

AmpereRating

CatalogNumber

UL Interrupting Breaker Ratings (kA)Volts AC 120/240

QPP2-Pole120/240V AC

125 Q2125B 10150 Q2150B 10175 Q2175Bn 10200 Q2200B 10225 Q2225B 10

QPPH2-Pole120/240V AC

125 Q2125BH 22150 Q2150BH 22175 Q2175BHn 22200 Q2200BH 22225 Q2225BHn 22

HQPH2-Pole, 120/240V AC

100 HQ2100H 100125 HQ2125H 100

HQPP2-Pole120/240V AC

125

Obsolete150175200225

HQPPH2-Pole120/240V AC

100

Obsolete

125150175200225

Circuit BreakersMain and Branch Circuit Breakersa

Product Category RESI

MBK MBK (100,125)A (150,200,225)A

QNRe QNe

2-Pole QPP

QPJ

EQ9675

Revised on 10/31/18

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-42

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

a All standard circuit breakers are calibrated to 40°C maxi-mum ambient application.

Type QPF, QPHF, QE, QAF2, QAF2H

Type QN, QNH, HQN Type QNR, QNRH, HQNR

Type QT

3"

23/8"

31/8"

1-Pole 2-Pole 3-Pole

QP, QPH, HQP

Type EQ8681, EQ8682 Type EQ8693, EQ8695, EQ8696

Type QPP, QPPH, HQPP, HQPPH

Type QPJ

Circuit BreakersLine Diagrams/Dimension Drawings

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-43

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

Circuit BreakersLug Data

Circuit Breaker TypeCircuit BreakerAmpere Rating

CablesPer Connector

ConnectorWire Range

LOAD SIDE

QP, QPH, HQP, Plug-in 10 1 or 2 #14-#16 AWG Cu

15–35 11

#14–#6 AWG Cu #14–#6 AWG Al

40–50 11

#8–#6 AWG Cu #8–#4 AWG Al

55-125 11

#8-#2/0 AWG Cu#8-#2/0 AWG Al

QP 1 & 2-Pole Only 55-60 1 #6-#4 AWG Cu-Al (#3 AWG compatible with QPH & HQP)

QT 15–35 11

#14–#6 AWG Cu #14–#6 AWG Al

40 1 #8 AWG CU-Al

40–50 Exception: 1 & 2-pole QP at 55-60

11

#8–#6 AWG Cu#8–#4 AWG Al

QPF, QPHF 15–30 11

#14–#10 AWG Cu#12–#8 AWG Al

40–60 11

#8–#6 AWG Cu#8–#4 AWG Al

QAF2, QAFH2, QFGA2, QFGAH2

15–20 11

#14–#12 AWG Cu#12–#10 AWG Al

QD 15–20 2 #14–#10 AWG Cu Only

15–20 11

#14–#12 AWG Cu#12–#10 AWG Al

25–35 11

#10–#8 AWG Cu#10–#6 AWG Al

40–60 11

#8–#6 AWG Cu#8–#4 AWG Al

QN, QNH, HQN 150–200 1 #1–300kcmil Cu-Al

QS, QSH, QSHH, HQS, HQSH 100–225 1 #3–300kcmil Cu-Al

EQ8681-Ultimate, PL, ES 100 1 #4–3/0 AWG Cu-Al

EQ8682-Ultimate, PL, ES 125 1 #4–3/0 AWG Cu-Al

EQ8693-Ultimate, PL, ES 150 1 #1–300kcmil Cu-Al

EQ8695-Ultimate, PL, ES 200 1 #1–300kcmil Cu-Al

EQ8696-Ultimate, PL, ES 225 1 #1–300kcmil Cu-Al

QPP, QPPH, HQPP, HQPPH

125 11

#1 AWG Cu#2/0 AWG Al

150 11

#1/0 AWG Cu#3/0 AWG Al

175 11

#2/0 AWG Cu#4/0 AWG Al

200 11

#3/0 AWG Cu250kcmil AWG Al

225 11

#4/0 AWG Cu300kcmil AWG Al

EQ9675-EQIII 100 11

#8-#2/0 AWG Cu#8-#2/0 AWG Al

EQ9677-EQIII 125 11

#8-#2/0 AWG Cu#8-#2/0 AWG Al

EQ9683-EQIII 150 11

#1/0 AWG Cu#3/0 AWG Al

EQ9684 175 11

#3/0 AWG Cu250kcmil AWG Al

EQ9685-EQIII 200 11

#2/0 AWG Cu#4/0 AWG Al

EQ9686-EQIII 225 11

#4/0 AWG Cu300kcmil AWG Al

QPJ 125–200 1 #2–300kcmil Cu-Al

Revised on 10/31/18

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-44

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

Circuit BreakersCircuit Breaker Accessories

Product Category RESI

a For a complete list of standby power mechanical interlock kits, see page 1-25

b For use with Ultimate Load Center Main Breakersc Not suitable for use on 15-50A, 10 AIC Type QP Circuit

Breakers

d QP Type includes QPH, HQPe BL Type includes BLH, HBLf BQ Type includes BQH, HBQ

g QAF2 Type includes QAFH2, BAF2, BAFH2, QFGA2, QFGAH2, BFGA2, BFGAH2

h QPF Type includes QPHF, BLF, BLHF i QE Type includes QEH, BLE, BLEH

Circuit Breaker Accessories defghi

Catalog Number For Use With Breaker Type Number of Poles Standard Package

Padlocking Device For locking breaker in “OFF” position. Note “ON” position does not affect breaker fuctionally

ECPLD1 Type QP, BL, QAF2, QPF2, QE, QT-Duplex, BQ, BQXD 1P 3 PiecesECPLD1R Type QP, BL, QAF2, QPF, QE, QT-Duplex, BQ, BQXD

(Red Color)1P 3 Pieces

ECPLD2 Type QP, BL, QAF2, QPF, QE, QT-Triplex & Quadplex, BQ, BQXD

2P 3 Pieces

ECPLD2R Type QP, BL, QAF2, QPF, QE, QT-Triplex & Quadplex, BQ, BQXD (Red Color)

2P 3 Pieces

ECPLD3 Type QP, BL, QAF2, QPF, QE, BQ 3P 1 PieceUS2:ECPLD3R Type QP, BL, QAF2, QPF, QE, BQ (Red Color) 3P 1 PieceECQLD3 Type QP, BL, BQ, BQXD 1P 10 PiecesECQLD4 Type QT-Duplex QT-Duplex Breakers 10 Pieces

ECQLN3b 150-225 MBKA, QN, QNR n/a 1 PieceECQTH4 Type QP, BL, BQH Designed for (3) 1P Breakers 1 Piece

Handle Tie Provide simultaneous swiching of 2 adjacent handles.

ECQTH2 Type QT Duplex Designed for (2) QT Duplex Breakers 25 PiecesECQTH3 Type QP, BL 2P 50 Pieces

Mechanical Interlocka

ECQML12 Type QP, BL, BQ Interlock Bracket Designed for 1” Breaker 10 Pieces

Handle Blocking Device For holding breaker in “ON” or “OFF” position. Not a lockout/tagout device

ECQL1 Type QP, BL, BQ, BQXD 1P 10 PiecesECBX231M Type QT-Duplex 1/2” Breakers 10 Pieces

Main Breaker Retainer

ECMBR1c EQ Load Centers 1 PieceECMBR2 PL, ES, and Ultimate Load Centers: 2-pole QP 1 PieceECMBR3 PL, ES, and Ultimate Load Centers: 3-pole QP 1 Piece

Mounting Accessories

MB120 Type BQ, BQH Mounting Clips 1P 20 PiecesFP9508 Type BQ, BQH FACE MOUNT PLATE 1P 10 PiecesFP9555 Type BQ, BQH FACE MOUNT PLATE 2P 10 PiecesFP9556 Type BQ, BQH FACE MOUNT PLATE 3P 10 PiecesSMB6R Type BQ MOUNTING BRACKET 1P, 2P, 3P 6 PiecesTCH65K Type BQ MOUNTING ADAPTER 500 PiecesBR2 Type BQ, BQH, BQXD Back Mounting Plates 2P 10 PiecesBR3 Type BQ, BQH, BQXD Back Mounting Plates 3P 10 PiecesBR4 Type BQ, BQH, BQXD Back Mounting Plates 4P 10 PiecesI0204ML1125CU Type QP Back Mounting Plates 1P, 2P 10 PiecesI0303ML3100CU Type QP Back Mounting Plates 3P 10 Pieces

Replacement Lugs

TA1Q1 Type BQ, NGG 100A Al Cu LGS n/a 6 PiecesTC1Q1 Type BQ, NGG 40A Al Cu LUGS n/a 6 Pieces

Finger Shield

BQFS1K Type BQXD Finger Shield (Bulk Pack) n/a 1000 PiecesBQFS2 Type BQXD Finger Shield n/a 2 Pieces

Filler Plate

ECQF3 1” Filler Plate n/a 5 Pieces

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-45

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

Mechanical Interlock

ECQML12

Circuit BreakersCircuit Breaker Accessories

Padlocking Device

ECPLD1R/2R/3R (Single pole pictured. 2-/3-pole available) ECQLD4 ECQTH4ECPLD2

ECPLD1 ECQLD3

Handle Tie

ECQTH3ECQTH2

Handle Blocking Device

ECBX231M

ECQL1

Main Breaker Retainer

ECMBR2ECMBR1

Mounting Accessories

MB120 I0204ML1125 SMB6R

FP9508

FP9555

FP9556

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-46

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

Featuresn 2 inch wide plug-on design

— Includes (2) 1 Pole circuits breakers

— No loss of load center spaces

n Easy to install and perfect for retrofit

n LEDs provide protection status

BenefitsBy installing a Siemens Circuit Breaker and Surge Protective Device (SPD) in the load center of the residence, surge protection is provided for all branch circuitsa.

Two green LED indicator lights are provided to show that surge protection is provided for all circuits connected to the load center. These breakers should be used for circuit protection of frequently used household or facility circuits because the lights and devices connected to these circuits provide an effective indication that surge protection is being provided.

The circuit breaker and SPD utilize Siemens-built 150V AC, 40mm, metal oxide varistors (MOVs). The maximum impulse rating for the SPD module is 40kA. The standard interrupting rating for the circuit breakers is 10k AIC. All Type QP circuit breakers and SPD are plug-on style, with load terminals provided. The devices are rated for 120/240V AC and are calibrated for 40 degrees C maximum ambient applications.

Breaker Type Ampere Rating Catalog Number Surge Type

QP(2) 15 QSA1515SPD SPD

1- Pole

120/240V AC(2) 20 QSA2020SPD SPD

10K AIC

Catalog Number QSA1515SPDQSA2020SPD

Amperage 15 or 20 AmpNumber of Poles (2) 1-Pole Circuit BreakersInitial Clamping Level 240 VoltsTransient Energy Rating 360 Joules line-to-neutral

720 Joules line-to-lineTransient Suppression 500 volts peak, line-to-neutralVoltage Rating 1000 volts peak, line-to-linePeak Current Rating (impulse) 40,000 amperesDischarge Voltage Characteristic @ 1,500A, 600 volts

@ 5,000A, 800 volts(both line-to-neutral)

Discharge Current Withstand Rating 10,000 amperesline-to-neutral

Circuit Breaker Interrupting Rating 10,000A, 120/240V ACListings/Certifications UL, CSA

Meets UL 1449 4th Edition

a For warranty information please refer to the surge website www.usa.siemens.com/surge

Circuit Breaker and Surge Protective Device (SPD)

Surge ProtectionCircuit Breaker and Surge Protective Device (SPD)

Product Category RESI

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-47

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

Surge ProtectionPower Service Entrance Surge Protection

FirstSurgeTM - Power, Plus, or Pron 4th Listed, Type 2, Surge Protective Device (SPDn Surge Current Capacities:

– 60,000 A,FirstSurge Power (FS060) – 100,000 A,FirstSurge Plus (FS100) – 140,000 A, FirstSurge Pro (FS140)

n 3 Stage Commercial Grade Notification: – Protection Status LEDs – Audible Alarm – Flashing Red Service LED

n Ground Reference Monitoring (GRM)n 10 year product & connected equipment warranty** See www.usa.siemens.com/surge for warranty terms and conditions.

Surge Type Catalog Number

FirstSurge Power FS060FirstSurge Plus FS100FirstSurge Pro FS140

AC Surge ProtectionUL and CSA Listings 1449 4th Edition & CSA 22.2 No. 269.2Surge Spike Capacity 60kA, 100kA, or 140kALine Voltage 120/240 1 Phase 50/60 HzUL 1449 4th Edition VPR L-N, L-G, N-G: 600 V; L-L: 900VRated Voltage (MCOV) L-N, L-G, and N-G: 150V; L-L: 300VShort Circuit Current Rating (SCCR) 100kA

Inominal (In) Rating 20kAResponse Time <1 nanosecondEnclosure NEMA 4X Indoor and Outdoor RatedProduct Warranty 10 years

Type 1 SPD / Surge Arrestor Replacement

Product Category RESI

A C

GN

BREAKER

susa.siemens.

1-888-333-3545com/surge

susa.siemens.

1-888-333-3545com/surge

Use closest breaker to SPDLocate SPD close to intendedbreaker (max. 30A)

Keep Leads Short as PossibleAvoid Sharp Bends

Outdoor installation requires appropriateweather sealing at nipple (gasket, sealingconduit, etc.)

Rotate FirstSurge™ such that LEDindicator is most visible

To Protected Loads

FirstSurge – FS060, FS100, FS140

TPS3 03 is a UL 1449 4th Edition 50 kA Type 1 compact surge protective device that can be used as a replacement second-ary surge or lighting arrestors. Having a Type 1 designation allows for flexible electrical system connection location (line or load side) as well as UL 96A compliance (@ 20 kA In).

TPS3 03 Key Featuresn UL 1449 4th Edition Listed Type 1n Type 1 Rated SPDn 50 kA Per Phase Surge Currentn 20 kA In (Most models)n 200 kA SCCR (Most modelsn UL 96A Lightning Protection Master Labeling compliant

(@ 20 kA))n Every MOV is monitoredn Mounts external to electrical distribution equipment – Recommend for Line Side or Load Side Applicationsn Standard compact NEMA 4X polycarbonate enclosuren Modes of Protection: L-N or L-G and L-Ln Standard Monitoring: LED Indicatorn Dimensions: 3.25” x 3.25” x 3.3”

(82.6 mm x 82.6 mm x 83.8 mm)n Weight: 2 lb. (0.9 kg)n 2 Year Product Warranty

Available Options:n Dry contacts & Audible Alarm (option “D”)

TPS3 03

TPS3 01 DIN RAIL Mounting

Ordering Information

Surge Current (kA)

05 = 50 kA per phaseVoltage CodeA = 120/240 V, 1Ø, 3WB = 120/240 V, 3Ø, 4WC = 120/208 V, 3Ø, 4WD = 240 V, 3Ø, 3WE = 277/480 V, 3Ø, 4WF = 480 V, 3Ø, 3WG = 600 V, 3Ø, 3WK = 380/220 V, 3Ø, 4WL = 600/347 V, 3Ø, 4W

Available Accessories: Ordered Separately

RMSIE = Remote monitor

Catalog # TPS3 03

Example: TPS3C0305D0 = Type 1 SPD for a 208/120V application with a surge current capacity of 50 kA per phase, in a standard NEMA 4X enclosure with dry contacts and audible alarm option.

When an option is not selected, include a zero (0) in the field.

Options

D = Dry contact & audible alarm

N = Adds N-G Protection

TPS3 03

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-48

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

FSCATVn UL/cUL listed surge protection

n Rated for CATV, DSS, TV, VCR, and Cable Modem

n Easy to install

n Standard Female to Female F connector

n Low insertion loss

n Automatic recovery

n 5 Year product warranty** See www.usa.siemens.com/surge for warranty terms and conditions.

FSPHONE & FSPHONE4X n UL/cUL listed

n Hardwired Telephone/Modem/Fax/DSL protection

n Exceptionally fast response time

n Low insertion loss

n Available with or without enclosure

n 5 Year product warranty*

* See www.usa.siemens.com/surge for warranty terms and conditions.

The Siemens FSPHONE & FSPHONE4X is a 2 pair, hardwired surge protector designed to stop surges from entering through the main telephone incoming service connection. It is equipped with a failshort device to permanently ground the telephone line in the event of a power cross. The FSPHONE is designed for indoor applications where the FSPHONE4X is useed for outdoor mounting is required.

The FSPHONE4X includes the FSPHONE plus a weatherproof enclosure to facilitate indoor or outdoor applications. The enclosure is molded of temperature and humidity resistant thermoplas-tic to resist cracking and discoloration. The cover can be secured with a tie wrap or similar locking device. Surge Type Catalog Number

Telco FSPHONETelco FSPHONE4X

AC Surge Protection

Catastrophic Surge Circuit YesSpike Capacity 200 AmpsLet Through Voltage <270VOvercurrent Protection YesResponse Time <1 nanosecondEnvironmentally Sealed YesUL/cUL Listings 497AMeets Telcordia (formallly Bellcore) GR-974-CORE Requirements for Telecommunications Line Protectors

Yes

Product Warranty 5 years

Coaxial Service Entrance Surge Protection

Siemens FSCATV shields coaxial connected electronics in residential and light commercial applications against electrical transient damage, including lightning, from entering through the main cable connection.

FSCATV includes a section of coaxial cable with female to female splice for line side application. The Siemens warranty covers product defects for 5 years. To have complete protection for your equipment, home, or business, it is important to protect AC power lines and all data lines the equipment is connected through.

Surge Type Catalog Number

Coaxial FSCATV

AC Surge Protection

Frequency Range DC thru 1.5 GHz Catastrophic Surge Circuit YesSpike Capacity 5000 Amps, 8/20 µSecImpedance 75 OhmsOvercurrent Protection YesReturn Loss 30dB @ 1 GHzInsertion Loss <0.1dB

UL/cUL Listings 497B

Meets IEEE C62.41.1 Requirements YesProduct Warranty 5 Years

SPD - Surge Protective DeviceTelephone Service Entrance Surge Protection

Product Category RESI

FSPHONE4XFSPHONE

FSCATV

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-49

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

WN2060 WN2060GFCI WNAS2060GFCIWF2060PL

Wire Range Table Copper Aluminum Connector Solid Stranded Solid Stranded Line #14-8 #14-3 #12-8 #12-3 Load #14-8 #14-3 #12-8 #12-3 Neutral #12-8 #12-2 #12-8 #12-2 Equip. Grnd #12-8 #12-2 #12-8 #12-2

Steel AC Disconnectsa

Ampere Disconnect Horse Power Dimensions Pallet Rating Type Catalog Number Rating Height Width Depth Qty. 30 Fused Pullout WF2030 3 71⁄4 5 21⁄8 360 60 Fused Pullout WF2060 10 9 5 21⁄8 360 60 Non-fused Pullout WN2060 10 71⁄4 5 21⁄8 360 60 Non-automatic Switch WNAS2060 10 71⁄4 5 21⁄8 360

Plastic AC Disconnectsa

Steel AC Disconnects with 15 Amp GFCI Receptaclea

Ampere Disconnect Horse Power Dimensions Pallet Rating Type Catalog Number Rating Height Width Depth Qty. 30 Fused Pullout WF2030GFCI 3 9 61⁄8 53⁄16 112 60 Fused Pullout WF2060GFCI 10 9 61⁄8 53⁄16 112 60 Non-fused Pullout WN2060GFCI 10 71⁄8 53⁄4 53⁄16 144 60 Non-automatic Switch WNAS2060GFCI 10 71⁄8 53⁄4 53⁄16 144

a Accepts Class H Fuse

Ampere Disconnect Horse Power Dimensions Pallet Rating Type Catalog Number Rating Height Width Depth Qty. 30 Fused Pullout WF2030PL 3 71⁄4 5 21⁄2 216 60 Fused Pullout WF2060PL 10 71⁄4 5 21⁄2 216 60 Non-fused Pullout WN2060PL 10 71⁄4 5 21⁄2 360 60 Non-Fused Pullout WN2060PLX 10 8 53⁄4 31⁄2 288 60 Non-automatic switch WNAS2060PL 10 71⁄4 5 21⁄2 360

AC Disconnects1-Phase, NEMA 3R Rated

Product Category RESI

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-50

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

a 100-225A only.b Standard package quantity equal to 1.c Dimensions shown are representative of outside box

length, width & depth (± 1⁄8”) and do not include allow-ance for mounting bumps, endwalls, hubs or hardware

protrusions. Allow approximately 11⁄4” additional in length and width dimensions for surface or combination over-hang. Consult factory for specific details if required.

d Hub provision only. Closure plate included. Panels through 225A require HS type hub; panels over 225A require HV type hub. See accessories page 1-44 for hub selection.

e Copper bus load centers are recommended for those applications where the environment may be severe (ie farm and coastal areas).

f Units manufactured after April 10, 2014 are UL listed for Siemens and Murray Breakers

g Heights shown are for Series A. Original series heights are listed on page 1-19.

Rock Solid Load Centersf

Main Lug Only, 1Ø, 65,000 AICa, Main Lug Panels 3-Wire 120/240V AC or 208Y/120V AC, Insulated and Bonded Split Neutrals

Load centers on this page through 225 amp feature a split neutral insulated bars. For service entrance applications, install bonding strap, and use both bars for neutral and ground conductors. For non service entrance applications, do not install bonding strap and use insulated bars for neutral conductors and bonded bar for ground conductors.

LW2040L1200

Siemens­/­Speedfax­ Previous­folio:­Murray­ SS­2/14/11

12-42 Circuit, 125–225 AmperesAmpsMax.

No. ofSpaces

Max.Circuit

Indoor Type 1b Dimensionsc Outdoor Type 3Rbd Dimensionsc

Catalog Number Heightg Width Depth Catalog Number Height Width Depth125 12 24 LC1224L1125 18 143⁄8 4 LW1224L1125 20 141⁄4 41⁄2125 16 32 LC1632L1125 21 143⁄8 4 LW1632L1125 29 141⁄4 41⁄2125 20 40 LC2040L1125 21 143⁄8 4 LW2040L1125 29 141⁄4 41⁄2125 30 40 LC3040L1125 30 143⁄8 4 — — — —150 16 32 LC1632L1150 24 143⁄8 4 — — — —150 24 40 LC2440L1150 30 143⁄8 4 — — — —200 12 24 — — — — LW1224L1200 29 141⁄4 41⁄2200 20 40 LC2040L1200 24 143⁄8 4 LW2040L1200 29 141⁄4 41⁄2200 24 40 LC2440L1200 30 143⁄8 4 — — — —200 30 40 LC3040L1200 30 143⁄8 4 LW3040L1200 38 141⁄4 41⁄2200 40 40 LC4040L1200 36 143⁄8 4 — — — —225 40 60 LC4060L1225 36 143⁄8 4 — — — —

Copper Buse

AmpsMax.

No. ofSpaces

Max.Circuit

Indoor Type 1b Dimensionsc Outdoor Type 3Rb Dimensionsc

Catalog Number Heightg Width Depth Catalog Number Height Width Depth125 20 40 LC2040L1125CU 21 143⁄8 4 — — — —200 20 40 LC2040L1200CU 24 143⁄8 4 — — — —200 30 40 LC3040L1200CU 30 143⁄8 4 — — — —200 40 40 LC4040L1200CU 36 143⁄8 4 — — — —225 12 24 — — — — LW1224L1225CU 29 141⁄4 41⁄2225 42 42 LC4242L1225CU 39 143⁄8 4 LW4242L1225CU 42 141⁄4 41⁄2

Revised on 11/01/17

Product Category RESI

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-51

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

Rock Solid Load Centersf

Main Lug Only, 1Ø, 65,000 AICa, Main Lug Panels 3-Wire 120/240V AC or 208Y/120V AC, Insulated and Bonded Split Neutrals

a 100-225A only.b This information is based on use of 10,000 AIC rated

branch circuit breakers in load center (MP-T, MH-T, MP-GT, MG). Most series ratings exclude MH-T above 40 Amp. Consult device wiring diagram for spe-cific data.

c Remote Onlyd Types MQH & MQL may be mounted internal in 150-225

amp 3Ø main breaker load centers.

e Dimensions shown are representative of outside box length, width & depth (±1⁄8”) and do not include allowance for mounting bumps, endwalls, hubs or hardware protru-sions. Allow approximately 11⁄4” additional in length and width dimensions for surface or combination overhang. Consult factory for specific details if required.

f Hub provision only. Closure plate included. Panels through 225A require HS type hub; panels over 225A require HV type hub.

g Standard package quantity equal to 1.h Copper bus load centers are recommended for those

applications where the environment may be severe (ie farm and coastal areas).

i Units manufactured after April 10, 2014 are UL listed for Siemens and Murray Breakers

Heights shown are for Series A. Original series heights are listed on page 1-19.

Rock Solid Load Centersi

Main Breaker, 1Ø, 22,000 AICa

Load Center Short Circuit Current Rating

Copper Bush

Amps No. of Max. Indoor Type 1g Dimensionse Max. Spaces Circuit Catalog Number Height Width Depth 100 20 40 LC2040B1100CU 21 143⁄8 4 200 20 40 LC2040B1200CU 30 143⁄8 4 200 30 40 LC3040B1200CU 36 143⁄8 4 200 40 40 LC4040B1200CU 36 143⁄8 4

Load Center Short Circuit Current Rating Load Center Internal or Remote Short Circuit Load Center Main or Feeder Current Ratingb Main Rating Circuit Breaker Type 10,000 AIC Any Any 22,000 AIC 100/125A MP-HT, MQHcd

150/200/225A MD-H, MQHbd, MPP-HTc

42,000 AIC 100/125A MQLcd

150/200/225A MQLbd

65,000 AIC 100/125A MP-MT, MPP-MTc

150/200/225A MPP-MTc

100,000 AIC 100/125A 100A, 300V AC, Class “T” Fusec

100,000 AIC 150/200/225A 200A, 300V AC, Class “T” Fusec

LC2040B1200

Load centers on this page through 200 amp feature a new split neutral with one bonded and one insulated bar. For service entrance applications, install bonding strap, and use both bars for neutral and ground conductors. For non service entrance applications, do not install bonding strap and use insulated bar for neutral conductors and bonded bar for ground conductors.

Siemens­/­Speedfax­ Previous­folio:­Murray­ SS­2/14/11

12-42 Circuit, 100-200 AmperesAmpsMax.

No. ofSpaces

Max.Circuit

Catalog Number Dimensionse Outdoor Type 3Rfg Dimensionse

Indoor Type 1g Height Width Depth Catalog Number Height Width Depth100 12 24 LC1224B1100 18 143⁄8 4 LW1224B1100 23 141⁄4 41⁄2100 16 32 — — — — LW1632B1100 23 141⁄4 41⁄2100 20 40 LC2040B1100 21 143⁄8 4 — — — —100 24 40 LC2440B1100 24 143⁄8 4 — — — —100 30 40 LC3040B1100 30 143⁄8 4 — — — —150 16 32 LC1632B1150 24 143⁄8 4 — — — —150 20 40 LC2040B1150 30 143⁄8 4 LW2040B1150 29 141⁄4 41⁄2150 24 40 LC2440B1150 30 143⁄8 4 — — — —150 30 40 LC3040B1150 36 143⁄8 4 — — — —200 12 24 — — — — LW1224B1200 29 141⁄4 41⁄2200 16 32 LC1632B1200 24 143⁄8 4 — — — —200 20 40 LC2040B1200 30 143⁄8 4 LW2040B1200 29 141⁄4 41⁄2200 24 40 LC2440B1200 30 143⁄8 4 — — — —200 30 40 LC3040B1200 36 143⁄8 4 LW3040B1200 38 141⁄4 41⁄2200 40 40 LC4040B1200 36 143⁄8 4 LW4040B1200 38 141⁄4 41⁄2200 30 54 LC3054B1200 36 143⁄8 4 — — — —200 40 40 LC4040B1200 36 143⁄8 4 — — — —200 40 60 LC4060B1200 36 143⁄8 4 — — — —

Murray load centers have UL recognized short circuit current ratings up to 100,000 Amps, when used with appropriate main or feeder (remote or internal) overcurrent devices. Load center ratings are shown below. For load center applications with residential or commercial metering equipment, refer to the appropriate catalog section.

1Ø, main breaker load centers are Underwriter’s Laboratories Listed for use with 60/75°C conductors and accept Murray branch circuit breakers which are also UL Listed for use with 60/75°C conductors. Type 3R load centers are furnished with a hub opening closure plate.

Revised on 11/01/17

Product Category RESI

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-52

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

Catalog Number Description Pack Quanity

MBK100M 100A—For use on 100 & 125A Rock Solid Load Centers only 1

MBK125M 125A—For use on 125A Rock Solid Load Centers only 1

MBK150M 150A—For use on 150, 200, & 225A Rock Solid Load Centers only 1

MBK200M 200A—For use on 200 & 225A Rock Solid Load Centers only 1

MBK225M 225A—For use on 225A Rock Solid Load Centers only 1

ECMLK125 1 PH Main Lug Conversion Kit 100-125A 1ECMLK225 1 PH Main Lug Conversion Kit 150-225A 1

Load CentersElectricenter Accessories

Hubs

ECQFL2 QF3/ECQF3

MBK100M MBK200M

Insulated Neutral Kit

ECHS125

Backfed Main Breaker Hold Down Kits

Miscellaneous

Main Breaker Kits

Lug Kits

Ground Bars and Insulated Neutral Kits

ECMBR2

ECLX388HD

ECMBR1

ECLX387HD

ECLX386HD

Siemens­/­Speedfax­ Previous­folio:­Murray­ SS­2/14/11

Catalog Number Description Pack QuanityECLX068M 4 small terminals—15⁄8” long 10ECLX069M 5 small and 2 large terminals—3” long 10ECLX071M 8 small and 3 large terminals—31⁄2” long 10ECLX072M 11 small and 4 large terminals—45⁄8” long 10ECLX073M 14 small amd 5 large terminals—53⁄4” long 10ECLX074M 17 small amd 6 large terminals—7” long 10ECLX075M 21 small amd 7 large terminals—8” long 10ECINSNB27 Insulated neutral bar with 27 positions 10ECINSNB32 Insulated neutral bar with 32 positions 10

ECINSNB33 Insulated neutral bar with 33 positions and a 300 MCM lug 10

ECINSNB41 Insulated neutral bar with 41 positions and a 300 MCM lug 10

ECINSNB43 Insulated neutral bar with 43 positions 10

Catalog Number Description Pack Quanity

ECLK2SC #2/0 max. lug for 125 amp neutral feeder for 12–42 circuit devices 50

ECLX384M CB enclosure ground lug 20

Catalog Number Description Pack QuanityECQFL2 Door lock for Rock Solid Load Centers 10ECQF3 Filler plate (1”) 10

ECMBF125Filler plate for main breaker opening on 100–125A Rock Solid Load Centers. Use two QF3 filler plates for 150–225A load centers

25

LX077SF Flush installation cover for 400A panels 1ECTS2 6 Cover screws, combination cover 50 Bags

ECSMK1 Surface mount spacer kit provides 1⁄4” space between load center and wall 25

Catalog Number Description Pack Quanity

ECMBR2 For use on MP-T, MP-HT, & MP-MT breakers in Rock Solid Load Centers 25

ECMBR1 For use on MP-T, MP-HT, & MP-MT breakers in 2 –8 circuit Load Centers 25

ECLX378M For use on MD-T, MD-HT, & MD-MT breakers on old style (pre 2003) load centers (12–42 circuit) 25

ECLX386HDFor use on MP-T, MP-HT, & MP-MT breakers (15–60A) on old style (pre 2003) load centers (12–42 circuit)

25

ECLX387HDFor use on MP-T, MP-HT, & MP-MT breakers (70–125A) on old style (pre 2003) load centers (12–42 circuit)

25

ECLX388HDFor use on MP-T, MP-HT, & MP-MT breakers (100–125A) on old style (pre 2003) load centers (12–42 circuit)

25

Catalog Number Description Pack QuanityECHS075 3⁄4” Hub 10ECHS100 1” Hub 10ECHS125 11⁄4” Hub 10ECHS150 11⁄2” Hub 10ECHS200 2” Hub 10ECHS250 21⁄2” Hub 10

Product Category RESI

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-53

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

Load CentersCatalog Number Logic

LC 30 40 L 1 200 CU

LC = Indoor Load Center LW = Outdoor Load Center - Type 3R

Spaces(max. No. of 1” breakers)

Circuits(max. No. of circuits)

Main AmpereRating

CU = Copper Bus Bar T = Feed Thru Lugs P = Value Pack

L = Main Lug B = Main Breaker

1 = 1Ø 3 = 3Ø

Lug Data

a All lugs are rated for Cu or AI wire. Wire rang shown is maximum allowable for bending space provided. Lug may accommodate larger wire. Refer to National Electric Code for specific wire size requirements.

b 500 kcmil must be top side entry.

Siemens­/­Speedfax­ Previous­folio:­Murray­1-11­­ NO­edits­rev2

Amps Phase

Wire Rangea

Main LugLoad Centers

Main BreakerLoad Centers

060 1Ø 14-4100 1Ø — 3-1/0125 (4 CKT) 1Ø 14-2/0 —125 (6 CKT & Above) 1Ø 4-2/0 4-2/0150 1Ø 1/0-4/0 4-250 kcmil

Amps Phase

Wire Rangea

Main LugLoad Centers

Main BreakerLoad Centers

200 1Ø 4-250 kcmil 4-250 kcmil225 1Ø 4-300 kcmil 4-300 kcmil400 (24 and 42 CKT) 1Ø (1)3/0-500 kcmilb (1or2)3/0-250 kcmil

(2)3/0-250 kcmil400 (30 CKT Only) 1Ø — (1)3/0-500 kcmil

(2)3/0-250 kcmil400 (24 and 42 CKT) 3Ø (1)3/0-500 kcmilb

(2)3/0-250 kcmil

Rock Solid Load Centers

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-54

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

Murray 3-Phase Cross Reference to New SKUs

(See Section 1 for full offering)

Legacy Murray SKU ES™ Series Part No. PL™ Series Part No.

LC1224B3100CU S1224B3100 P1224B3100CU

LC1224L3125CU S1224L3125 P1224L3125CULC1224L3200CU S1224L3200 No equivalentLC1836B3100CU No equivalent No equivalentLC1836L3150CU S1836L3150 No equivalentLC1836L3200CU S2442L3200 No equivalentLC2442L3150CU S2442L3150 P2442L3200CULC3042B3150CU S4242B3150 P4242B3150CULC3042B3200CU S3054B3200 P3054B3200CULC3042L3200CU S3054L3200 P3054L3200CULC4242B3200CU S4260B3200 P4260B3200CULC4242B3225CU S4242B3225 P4260B3225TCU/P4260B3225CU LC4242L3225CU S4260L3225 P4260L3225CULW1224L3125CU SW1224L3125 PW1224L3125CULW1836L3150CU SW1836L3150 No equivalentLW3042B3200CU SW3054B3200 PW3054B3200CULW3042L3200CU SW3054L3200 PW3054L3200CUNew S3042B3100 —New S5470L3225 —New SW1224L3200 —New SW2442L3150 —New SW2442L3200 —New SW4260L3225 —New S3030B3100 —New SW2442B3150 —New SW4260B3200 —New SW4242B3225 —New — P3042B3100CU

Siemens­/­Speedfax­ Previous­folio:­Murray­ SS­2/14/11

New Murray Heights

Load Center

Height

Original Series A

LC1224B1100 18 18LC1224L1125 21 18LC1224L1125P 21 18LC1632B1150 24 24LC1632B1200 30 24LC1632L1125 21 21LC1632L1150 24 24LC2040B1100 24 21LC2040B1100CU 24 21LC2040B1100P 24 21LC2040B1150 30 30LC2040B1200 30 30LC2040B1200CU 30 30LC2040B1200P 30 30LC2040L1125 24 21LC2040L1125CU 24 21LC2040L1200 30 24LC2040L1200CU 30 24LC2440B1100 24 24LC2440B1150 30 30LC2440B1200 30 30LC2440L1150 30 30LC2440L1200 30 30LC2448B1100 24 24LC2448B1100P 24 24LC3040B1100 30 30LC3040B1150 36 36LC3040B1200 36 36LC3040B1200CU 36 36LC3040B1200P 36 36LC3040L1125 30 30LC3040L1200 36 30LC3040L1200CU 36 30LC3054B1200 36 36LC3060B1200P 36 36LC4040B1200 39 36LC4040B1200CU 39 36LC4040B1200P 39 36LC4040L1200 39 36LC4040L1200CU 39 36LC4060B1200 39 36LC4060L1225 39 36LC4242L1225CU 42 39LC4260B1200 42 39LC4260B1200P 42 39

Revised on 11/01/17

Murray Load CentersCross References

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-55

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

Knockout DiagramsRock Solid Load Centers (including Generator Ready)

Outdoor Main Breaker and Main Lug EnclosuresIndoor Main Breaker and Main Lug Enclosures

10 K.O.s For0.5”, 0.75”, 1”

Conduit

2 K.O.s For.038”, 0.5”, 0.75”, 1”,

1.25”Conduit

4 K.O.s For0.25” Conduit

12 K.O.s For.038”, 0.5”, 0.75”

Conduit

52 K.O.s For0.5”Conduit

10 K.O.s For1”, 1.25”, 2”, 2.5”

Conduit

12 K.O.s For0.5”Conduit

8 K.O.s For0.5, 0.75”Conduit

4 K.O.s For1”, 1.5”, 2”, 2.5”

Conduit

4 K.O.s For1”, 1.5” Conduit

K.O. dimensions refer to conduit trade size, not actual diameter.

C

CC

C

L

W D

BB

CC

B B

B BQ

L

W D

B

M

R

B BA A

A A

B

Q

Q

B

B B

B

M

M

M

A A

L

W D

N

C

A A A

A A

A A A A

AA A A

A A

A A A

NN

N

N

N

CC

C

C

C

B

B

B B

B

B

B

B

B B

Knockout Code—Conduit Sizes

g = 1⁄4 S = 1, 11⁄4, 11⁄2, 2, 21⁄2A = 1⁄2 T = 11⁄4B = 1⁄2,

3⁄4 U = 11⁄4, 11⁄2C = 1⁄2, 3⁄4, 1 V = 11⁄4, 11⁄2, 2D = 1⁄2, 1 W = 11⁄4, 2E = 1⁄2, 3⁄4, 1, 11⁄4 X = 11⁄4, 11⁄2, 2, 21⁄2F = 1⁄2, 11⁄4, 11⁄2 Y = 11⁄2, 2G = 3⁄4 Z = 11⁄2, 2, 21⁄2H = 3⁄4, 1 AA = 11⁄2, 2, 21⁄2, 3J = 3⁄4, 1, 11⁄4 BB = 11⁄2, 2, 21⁄2, 3, 31⁄2K = 3⁄4, 11⁄4 CC = 2, 21⁄2, 3, 31⁄2L = 1⁄2, 3⁄4, 1, 11⁄4, 11⁄2 EE = 2, 21⁄2, 3M = 3⁄4, 1, 11⁄4, 11⁄2 FF = 21⁄2, 3N = 3⁄4, 1, 11⁄4, 11⁄2, 2 GG = 21⁄2, 3, 31⁄2P = 1, 11⁄4 HH = 21⁄2, 3, 31⁄2, 4Q = 1, 11⁄4,11⁄2 JJ = 31⁄2, 4R = 1, 11⁄4, 11⁄2, 2 LL = 3 VV = 2

4 Circuit Indoor 8 Circuit Indoor 16 Circuit Indoor

Siemens­/­Speedfax­ Previous­folio:­Murray­ SS­2/14/11

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-56

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

GG

L

W D

E EGG

BBBBB

B

E E

BBBBB

B

GG GGE E

BBBBB

BE E

BBBBB

B

HS

L

W D

C C

C C

HS

L

W D

M

MMM

B

B

Knockout Code—Conduit Sizes

g = 1⁄4 S = 1, 11⁄4, 11⁄2, 2, 21⁄2A = 1⁄2 T = 11⁄4B = 1⁄2,

3⁄4 U = 11⁄4, 11⁄2C = 1⁄2, 3⁄4, 1 V = 11⁄4, 11⁄2, 2D = 1⁄2, 1 W = 11⁄4, 2E = 1⁄2, 3⁄4, 1, 11⁄4 X = 11⁄4, 11⁄2, 2, 21⁄2F = 1⁄2, 11⁄4, 11⁄2 Y = 11⁄2, 2G = 3⁄4 Z = 11⁄2, 2, 21⁄2H = 3⁄4, 1 AA = 11⁄2, 2, 21⁄2, 3J = 3⁄4, 1, 11⁄4 BB = 11⁄2, 2, 21⁄2, 3, 31⁄2K = 3⁄4, 11⁄4 CC = 2, 21⁄2, 3, 31⁄2L = 1⁄2, 3⁄4, 1, 11⁄4, 11⁄2 EE = 2, 21⁄2, 3M = 3⁄4, 1, 11⁄4, 11⁄2 FF = 21⁄2, 3N = 3⁄4, 1, 11⁄4, 11⁄2, 2 GG = 21⁄2, 3, 31⁄2P = 1, 11⁄4 HH = 21⁄2, 3, 31⁄2, 4Q = 1, 11⁄4,11⁄2 JJ = 31⁄2, 4R = 1, 11⁄4, 11⁄2, 2 LL = 3 VV = 2

HV

GG

L

W D

EE

EE

HV

GGBBB

BBB

BBB

BBB

400A Indoor

4 Circuit Outdoor8 Circuit Outdoor

400A Outdoor

Siemens­/­Speedfax­ Previous­folio:­Murray­ SS­2/14/11

Knockout DiagramsIndoor and Outdoor Enclosures

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-57

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

n Built to order. Allow 8 -10 weeks for delivery.a Not UL Listed as SWD Rated.

b White line neutral (pigtail) must be connected to the panel neutral for the device to function.

Ground Fault Equipment Protection (30mA)b

Type EQF circuit breakers provide protection of equipment from damaging line-to-ground fault currents by de-energizing the circuit for all ungrounded conductors of the faulted circuit.

Breaker Type

Amp Rating

10,000 A IR Catalog No.

22,000 A IR Catalog No.

MP-ET/MP-HET1-Pole120V AC

152030

MP115EGa

MP120EGa

MP130EG

MP115EGH na

MP120EGH na

MP130EGH n

MP-ET/MP-HET2-Polea

120/240V AC

15 MP215EG MP215EGH n

20 MP220EG MP220EGH n

30 MP230EG MP230EGH n

40 MP240EG MP240EGH n

50 MP250EG MP250EGH n

60 MP260EG n MP260EGH n 1-Pole GFCI 2-Pole GFCI

1-Pole Branch Feeder AFCI

AFCI and GFCI Accessories

1-Pole Combination Type AFCI

2-Pole Combination Type AFCI

Siemens­/­Speedfax­ Previous­folio:­Murray­ SS­2/15/11

Arc-Fault Circuit Interrupters (AFCI)AFCI’s detect arcing faults (an unintentional arcing condition in a circuit) that standard circuit breakers are unable to detect. The device is intended to mitigate the effects of arcing faults by functioning to de-energize the circuit when an arc fault is detected

Combination Type AFCIb

Detects all three possible types of arc faults: line-to-ground, line-to-neutral, and series.

Breaker Type

Ampere Rating

10,000 A IRCatalog Number

22,000 A IRCatalog Number

65,000 A IRCatalog Number

MP-AT2/MP-HAT2/MP-MAT21-Pole 120V AC

1520

MPA115AFCa

MPA120AFCa

MPA115AFCHna

MPA120AFCHna

MPA115AFCHHMPA120AFCHH

MP-AT2/MP-HAT22-Pole 120/240V AC

1520

MP215AFCa

MP220AFCa

MP215AFCHna

MP220AFCHna

——

Branch-Feeder AFCIDetects line-to-ground and line-to-neutral arcs.

MP-AT2/MP-HAT2/MP-MAT21-Pole 120V AC

15 20

MPA115AFa

MPA120AFaMPA115AFH na

MPA120AFH naMPA115AFHHMPA120AFHH

Description Catalog Number

Padlocking Device for 1” & Twin Breakers ECPLD1

Padlocking Device for 2” & Quad Breakers ECPLD2

Handle Blocking Device for 1/2” Circuit Breakers ECBX231M

NEW Dual Function AFCI/GFCIThe Dual Function Circuit Breaker combines Combination Type AFCI and GFCI, protecting against both Arc Faults and (5mA) Ground Faults. The device includes the Self Test feature, making it the first in class in electrical safety for homeowners.

MP-GAT2/MP-HGAT2/MP-MGAT21-Pole 120V AC

15 20

MP115DFMP120DF

MP115DFHMP120DFH

MP115DFMMP120DFM

• UL Listed• HACR Rated (Except where noted)• Standard 1 inch per pole format with

plug-in design

Ground-Fault Circuit Interrupters (Class A - 5mA)

b

Ground-fault circuit interrupters (GFCI) provide Class A ground fault protection. A GFCI is a device intended for personnel protection and will de-energize the circuit when a fault current to ground is 6 milliamperes or more.

Breaker Type

Amp Rating

10,000 A IR Catalog No.

22,000 A IR Catalog No.

MP-GT/MP-HGT1-Pole120V AC

15 MP115GFA MP115GFAHn

20 MP120GFA MP120GFAHn

25 MP125GFA MP125GFAHn

30 MP130GFA MP130GFAHn

MP-GT/MP-HGT2-Polea

120/240V AC

15 MP215GFA MP215GFAPn

20 MP220GFA MP220GFAPn

30 MP230GFA MP230GFAPn

40 MP240GFA MP240GFAPn

50 MP250GFA MP250GFAPn

60 MP260GFA MP260GFAPn

Ground Fault Interrupters and Protection

Circuit BreakersArc-Fault Circuit Interrupters (AFCI)

Product Category RESI

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-58

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

n Built to order. Allow 2-3 weeks for deliverya UL Listed for use with 60/75° wire through 40 amps,

UL listed for use with 75° wire only for 50 amps and above, HACR rated. 120V AC Fluorescent Lighting.

b 1A and 1B contacts.c UL Listed for use on 3 phase grounded “B” systems —

10,000 for this application.d UL Listed for frequent switching applications (SWD).e Shipped 12 per sleeve.

f Shipped 6 per sleeve.g Shipped 4 per sleeve.h UL Listed 5KA IR.i Not UL Listed. 1 & 2 Poles only.

MP-T / MP-HT / MP-MT Internal Accessories Description Catalog Number Field/Factory Installed120V Shunt Trip add suffix...STn Factory24V Shunt Trip add suffix...ST24Vn Factory120V Auxiliary Switch add suffix...ASnb Factory

Wiring Diagrams

1-Pole

2-Pole

3-Pole

Siemens­/­Speedfax­ Previous­folio:­Murray­ SS­2/15/11

ModificationsDescription Catalog Number400Hz Calibration add suffix...Y h

Marine 50˚ C Ambient add suffix...MCalibrationFungus Proofing add suffix...F

Continuous Current Rating @ 40° C

Type MP-Ta Type MP-HT Type MP-MT

10,000A IR 22,000A IR 65,000A IR

Catalog Number Catalog Number Catalog Number

1-Pole Plug-In (120/240V AC)e

10 MP110 — —15 MP115d MP115KHd MP115KMnd

20 MP120d MP120KHd MP120KMnd

25 MP125 MP125KHn MP125KMn

30 MP130 MP130KH MP130KMn

35 MP135n MP135KHn MP135KMn

40 MP140 MP140KH MP140KMn

45 MP145n MP145KHn MP145KMn

50 MP150 MP150KH MP15KKMn

60 MP160n MP160KHn MP160KMn

70 MP170n MP170KHn MP170KMn

2-Pole Plug-In (Common-Trip 120/240V AC )f

15 MP215 MP215KH MP215KMn

20 MP220 MP220KH MP220KMn

25 MP225 MP225KHn MP225KMn

30 MP230 MP230KH MP230KMn

35 MP235 MP235KHn MP235KMn

40 MP240 MP240KH MP240KMn

45 MP245 MP245KHn MP245KMn

50 MP250 MP250KH MP250KMn

60 MP260 MP260KH MP260KMn

70 MP270 MP270KHn MP270KMn

80 MP280 MP280KHn —90 MP290 MP290KHn MP290KMn

100 MP2100 MP2100KH MP2100KM110 MP2110 MP2110KH MP2110KMn

125 MP2125 MP2125KH MP2125KM

2-Pole Plug-In (Common-Trip 240V AC)cf

15 MPH215 — —20 MPH220 — —30 MPH230 — —40 MPH240n — —50 MPH250 — —60 MPH260 — —70 MPH270n — —100 MPH2100n — —

3-Pole Plug-In (Common-Trip 240V AC)g

15 MP315 MP315KH MP315KMn

20 MP320 MP320KH MP320KMn

25 MP325n MP325KHn —30 MP330 MP330KH MP330KM35 MP335n — —40 MP340 MP340KH MP340KM45 MP345n — —50 MP350 MP350KH MP350KM60 MP360 MP360KH MP360KM70 MP370 MP370KH MP370KMn

80 MP380 MP380KHn MP380KMn

90 MP390 MP390KHn MP390KMn

100 MP3100 MP3100KH MP3100KM

For external accessories please refer to page 1-47.

Circuit BreakersFull Size (1" per Pole) with INSTA-WIRE

Product Category RESI

Revised on 10/31/18

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-59

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

For external accessories please refer to page 1-47.

MH-T Duplex

n Built to order. Allow 2–3 weeks for delivery. a Non-CTL.. For replacement use only in panels manufac-tured before 1968.

These space saver duplex breakers combine two independent 1/2" breaker poles in a common unit. This unit plugs into one load center stab and requires one panel space. HACR rated.

MH-T Triplex

These space saver triplex breakers provide a 2-pole common trip breaker for 120/240V AC circuits and two single poles for 120V AC circuits. Triplex require two panel spaces. HACR rated.

MH-T Quadplex

These space saver quadplex breakers provide two sets of common trip, two-pole breakers for 120/240V AC circuits, and require two panel spaces. HACR rated.

Siemens­/­Speedfax­ Previous­folio:­Murray­ SS­2/15/11

Duplex Circuit Breakers

Breaker TypeAmpereRating Catalog Number Catalog Number

MH-T1-Pole10K AIC120V AC

15–15 MP1515 MP1515Na

15–20 MP1520 MP1520Nna

20–20 MP2020 MP2020Na

20–30 MP2030 MP2030Nna

15–30 MP3015n MP3015Nna

30–30 MP3030 MP3030Nna

SHIPPING: 12 per carton, (Wt. 4.8 lbs.)

Triplex Circuit Breakers

BreakerType

Ampere Rating

CatalogNumberSingle Pole

Common-Trip2-Pole

MH-T2-Pole10K AIC120/240V ACInner PolesCommon Trip.Outter Poles1 Pole Units

15 15 MP2151515 20 MP2201515 25 MP22515n

15 30 MP2301515 35 MP23515n

15 40 MP2401515 45 MP24515n

15 50 MP2501520 20 MP2202020 25 MP22520n

20 30 MP2302020 35 MP23520n

20 40 MP2402020 45 MP24520n

20 50 MP25020SHIPPING: 6 per carton, (Wt. 4.9 lbs.)

Quadplex Circuit Breakers

BreakerType

Ampere Rating

CatalogNumber

Common-Trip 2-Pole Outside

Common-Trip 2-Pole Inside

MH-T2-Pole10K AIC120/240V ACOutter andInner 2 PolesCommon Trip

15 15 MP21515CT215 30 MP21530CT220 15 MP22015CT220 50 MP22050CT230 20 MP23020CT230 25 MP23025CT230 30 MP23030CT230 50 MP23050CT240 20 MP24020CT240 30 MP24030CT240 40 MP240240CT2SHIPPING: 6 per carton, (Wt. 4.8 lbs.)

Circuit BreakersDuplex, Triplex and Quadplex Plug-in Breakers

Product Category RESI

Revised on 10/31/18

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-60

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

Breaker Type Ampere Rating Catalog Number Surge Type

QP(2) 15 MSA1515SPD SPD

1- Pole

120/240V AC(2) 20 MSA2020SPD SPD

10K AIC

Catalog Number MSA1515SPDMSA2020SPD

Amperage 15 or 20 AmpNumber of Poles (2) 1-Pole Circuit BreakersInitial Clamping Level 240 VoltsTransient Energy Rating 360 Joules line-to-neutral

720 Joules line-to-lineTransient Suppression 500 volts peak, line-to-neutralVoltage Rating 1000 volts peak, line-to-linePeak Current Rating (impulse) 40,000 amperesDischarge Voltage Characteristic @ 1,500A, 600 volts

@ 5,000A, 800 volts(both line-to-neutral)

Discharge Current Withstand Rating 10,000 amperesline-to-neutral

Circuit Breaker Interrupting Rating 10,000A, 120/240V ACListings/Certifications UL, CSA

Meets UL 1449 4th Edition

a For warranty information please refer to the surge website www.usa.siemens.com/surge

Siemens­/­Speedfax­ Previous­folio:­New­page­from­Powerpoint­ ­ Updated­by­S­Spencer­1-3-11

Featuresn 2 inch wide plug-on design

— Includes (2) 1 Pole circuits breakers

— No loss of load center spaces

n Easy to install and perfect for retrofit

n LEDs provide protection status

BenefitsBy installing a Siemens Circuit Breaker and Surge Protective Device (SPD) in the load center of the residence, surge protection is provided for all branch circuitsa.

Two green LED indicator lights are provided to show that surge protection is provided for all circuits connected to the load center. These breakers should be used for circuit protection of frequently used household or facility circuits because the lights and devices connected to these circuits provide an effective indication that surge protection is being provided.

The circuit breaker and SPD utilize Siemens-built 150V AC, 40mm, metal oxide varistors (MOVs). The maximum impulse rating for the SPD module is 40kA. The standard interrupting rating for the circuit breakers is 10k AIC. All Type QP circuit breakers and SPD are plug-on style, with load terminals provided. The devices are rated for 120/240V AC and are calibrated for 40 degrees C maximum ambient applications.

Circuit Breaker and Surge Protective Device (SPD)

Circuit BreakersCircuit Breaker and Surge Protective Device (SPD)

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-61

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

Switched Neutrals

n Built to order. Allow 2–3 weeks for delivery. Note: All circuit breakers on this page are 10K AIC

a UL Listed as SWD (Switching Duty) Rated, suitable for 120V AC Fluorescent Lighting.

Wiring Diagrams

HID LightingFor high-intensity discharge lamp loads having in-rush currents above the instantaneous trip setting of a standard breaker.

BreakerType

WiringDiagram

Complete Breaker UL Unenclosed

Ampere Rating Catalog Number

MP-T1-Pole120V AC

Figure 115 MP115HIDna

20 MP120HIDna

30 MP130HIDn

QP2-Pole120/240V AC

Figure 115 MP215HIDn

20 MP220HIDn

30 MP230HIDn

Molded Case SwitchMolded case non-automatic switch does not provide overload protection.

MP-T2-Pole240V ACPlug-In

Figure 2 3060

MP260NAMP230NA

Switched NeutralsFor use where all conductors are required to be disconnected. Neutral pole of breaker does not connect to loadcenter bus. One side is wired to neutral and the other to the device.

MG2-WireCommon Trip120V AC

Figure 3 1520

MP215SNMP220SN

MG3-WireCommon Trip120/240V AC

Figure 4 20 MP320SN

Figure 3 Figure 4

Circuit BreakersSpecial Application Breakers

Product Category RESI

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-62

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

Listed Panelboards—Square Db—Catalog Numbers

QO2L30F/S QO2-4L70F/S QO2-4L70TS QO2-4L70RB QO6-12L100F/S QO6-12L100DF/S QO6-12L100TF/S QO6-12L100DTF/S QO6-12L100RB QO8-16L100F/S QO8-16L100DF/S QO8-16L100TF/S QO8-16L100DTF/S QO8-16L100RB QO112M100/RB QO116M100/RB QO120M100/RB QO124M100 QO12L100DF/S QO12L100RB QO12-20M100/RB QO12-20M100TF/S

QO12M100/RB QO16-20M100/RB QO16M100/RB QO20M100/RB QO112L125G/RB QO112-24L125G/RB QO112-24L125GWGC QO116L125G QO116-24L125G/RB QO12-24L125/RB QO120-24L125G QO120-24L125GWGC QO120L125G QO124L125G/RB QO124M125/RB QO16L125/RB QO16-12M125FTRB QO16-24L125/RB QO20L125/RB QO20-24L125/RB QO24L125/RB QO120-30L150G

QO120-30M150/RB QO124L150G QO124M150 QO130L150G/RB QO130M150/RB QO16L150/RB QO16M150/RB QO16-30L150/RB QO18-16M150FTRB QO20-30M150/RB QO20-30M150TF/S QO20-30L150 QO24L150/RB QO24M150/RB QO30L150/RB QO30M150/RB QO8-16M200FT/RB QO112L200G/RB QO120-40M200/RB QO120-40M200TC QO124M200 QO130L200G/RB

QO130-40M200 QO130M200/RB QO130-40L200G/RB QO140M200/RB QO16L200/RB QO16M200/RB QO18-16M200FTRB QO20-40L200/RB QO20-40M200TF/S QO20-40M200/RB QO24L200/RB QO24M200/RB QO30L200/RB QO30M200/RB QO30-40L200/RB QO30-40M200/RB QO40M200/RB QO140M225 QO142L225G/RB

Panelboard Compatibility List

Features• 3/4" format.

• HACR Rated.

• UL Classified for use in certain Square Db

load centers.

Type MSQ Circuit BreakersThe Type MSQ circuit breaker line is available in 1-pole and 2-pole common trip versions listed on this page.

The circuit breakers are UL Classified and UL Listed.

All MSQ breakers are supplied with load side connectors suitable for 60/75°C wire and are calibrated for 40°C maximum ambient applica-tions.

UL ClassifiedMurray Type MSQ circuit breakers are UL Classified for use in specific Square Db load-centers in place of Square Db Type QO® cir-cuit breakers. A Panelboard Compatibility List packaged with each QD breaker shows which type MSQ circuit breakers are acceptable for use in Square Db load centers.

The interrupting rating on these circuit break-ers is 10,000A IR maximum and they are not series rated with Square Db circuit breakers or equipment. This UL Classification allows a Murray Type MSQ circuit breaker to be used in place of a Square Db Type QO circuit breaker in those load centers that are specifi-cally shown on the Panelboard Compatibility list. For additional information, contact your local Murray sales engineer.

a UL Listed for frequent switching applications (SWD). 120V AC Fluorescent Lighting. One or two load conductors.

b Square D is a registered trademark of Schneider Electric.

1-Pole 2-PoleWiring Diagrams

Number of Number Per Shipping Poles Carton Weight (lbs.)

1 16 3.8 2 8 4.2

Shipping Weights

ContinuousCurrent Rating@ 40°C

1-Pole 2-Pole

120V 120/240V Common Trip

Catalog Number Catalog Number

15 MQ115a MQ21520 MQ120a MQ22030 MQ130 MQ23040 MQ140 MQ24050 MQ150 MQ25060 MQ160 MQ260

Circuit BreakersType MSQ, 3/4 Inch Plug-In Breakers

Product Category RESI

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-63

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

n Built to order. Allow 2–3 weeks for delivery.a All circuit breakers on this page are common trip.b Reverse handle, ON toward lugs. See page 2-23.c Requires 4 panel spaces, 2 adjacent, and 2 opposite.d For use as load center branch and/or replacement main

for old-style load center.e Main breaker kit for Rock Solid load centerf Requires 6 spaces due to cross over design.

g 4-poles wide for use with 200A modular and Uni-Pak metering

h For use with breaker types MD-T(R), MD-HT(R), MD-MT(R)

i MD-TR required for horizontal mounting applications as shown, or for vertical applications when the lugs are on top. MD-T required for vertical mounting applications with the lugs on the bottom as shown.

MBK100M for use with 100A and 125A Rock Solid load centers only. MBK125M for use with 125A Rock Solid load centers only.

MBK150M for use with 150A, 200A, and 225A Rock Solid load centers only. MBK200M for use with 200A and 225A Rock Solid load centers only. MBK225M for use with 225A Rock Solid load centers only.

MD-TR, MD-HTR, MD-MTRi

M1 M2

Type MPP-T, MPP-HT, MPP-MT, MPP-PT

Type ED-A, ED-HA

MD-T, MD-HT, MD-MTi

Breaker TypeAmpereRating Catalog Number Catalog Numberbd

UL InterruptingRatings (kA)

MD-Tc

2-Pole120/240V AC

150 MPD2150 MPD2150R 10175 MPD2175n MPD2175Rn 10200 MPD2200 MPD2200R 10

MD-HTc

2-Pole120/240V AC

150 MPD2150KH MPD2150RH 22175 MPD2175KHn MPD2175RHn 22200 MPD2200KH MPD2200RH 22

MD-MTc

2-Pole120/240V AC

150 MPD2150KM MPD2150RM 65175 MPD2175KMn MPD2175RMn 65200 MPD2200KM MPD2200RM 65

Breaker TypeAmpereRating Catalog Number

UL InterruptingRatings (kA)

M1e

2-Pole120/240V AC

100 MBK100M 22

125 MBK125M 22

M2e

2-Pole120/240V AC

150 MBK150M 22

175 MBK175M 22

200 MBK200M 22

225 MBK225M 22

Breaker TypeAmpereRating Catalog Number

UL InterruptingRatings (kA)

ED-Af

3-Pole240V AC

125 EP3125 10150 EP3150 10200 EP3200 10175 EP3175 10225 EP3225 10

Breaker TypeAmpereRating Catalog Number

UL InterruptingRatings (kA)

MPPg

2-Pole120/240V AC

125 MPP2125 10150 MPP2150 10175 MPP2175n 10200 MPP2200 10225 MPP2225 10

MPP-HTg

2-Pole120/240V AC

125 MPP2125KH 22150 MPP2150KH 22175 MPP2175KHn 22200 MPP2200KH 22225 MPP2225KHn 22

MPP-MTg

2-Pole120/240V AC

125

Obsolete150175200225

MPP-PTg

2-Pole120/240V AC

100

Obsolete

125150175200225

Circuit BreakersMain and Branch Circuit Breakersa

Product Category RESI

Revised on 10/31/18

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-64

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

Circuit Breaker Accessories defg

Catalog Number For Use With Breaker Type Number of Poles Standard Package

Padlocking Device For locking breaker in “OFF” position. Note “ON” position does not affect breaker fuctionally

ECPLD1 Type MP-T, MP-AT2, MP-GT, MP-ET, MH-T-Duplex 1P 3 PiecesECPLD1R Type MP-T, MP-AT2, MP-GT, MP-ET, MH-T-Duplex

(Red Color)1P 3 Pieces

ECPLD2 Type MP-T, MP-AT2, MP-GT, MP-ET, MH-T-Triplex &Quadplex

2P 3 Pieces

ECPLD2R Type MP-T, MP-AT2, MP-GT, MP-ET, MH-T-Triplex &Quadplex, (Red Color)

2P 3 Pieces

ECPLD3 Type MP-T, MP-AT2, MP-GT, MP-ET 3P 1 PieceUS2:ECPLD3R Type MP-T, MP-AT2, MP-GT, MP-ET (Red Color) 3P 1 PieceECQLD3 Type MP-T 1P 10 PiecesECQLD4 Type MH-T-Duplex QT-Duplex Breakers 10 PiecesECQLN3b 150-225 M2, MD-T n/a 1 PieceECQTH4 Type MP-T, BL, BQH Designed for (3) 1P Breakers 1 Piece

Handle Tie Provide simultaneous swiching of 2 adjacent handles.

ECQTH2 Type MH-T Duplex Designed for (2) QT Duplex Breakers 25 PiecesECQTH3 Type MP-T, BL 2P 50 Pieces

Mechanical Interlocka

ECQML12 Type MP-T, Interlock Bracket Designed for 1" Breaker 10 Pieces

Handle Blocking Device For holding breaker in “ON” or “OFF” position. Not a lockout/tagout device

ECQL1 Type MP-T 1P 10 PiecesECBX231M Type MH-T-Duplex 1/2" Breakers 10 Pieces

Main Breaker Retainer

ECMBR2 Rock Solid Load Centers 1 Piece

Mounting Accessories

I0204ML1125CU Type MP-T, Back Mounting Plates 1P, 2P 10 PiecesI0303ML3100CU Type MP-T, Back Mounting Plates 3P 10 Pieces

Filler Plate

ECQF3 1" Filler Plate n/a 5 Pieces

n Built to order. Allow 2-3 weeks for deliverya For a complete list of standby power mechanical inter-

lock kits, see the Standby Generator Section XXXXb For use with Murray Rock Solid Center Main Breakers

c Not suitable for use on 15-50A, 10 AIC Type MP-T Circuit Breakers

d MP-T Type includes MP-HT, MP-MTe MP-AT2 Type includes MP-HAT2

f MP-GT Type includes MP-HGT g MP-ET Type includes MP-HET

Siemens­/­Speedfax­ Previous­folio:­Murray­ SS­2/15/11

Circuit BreakersCircuit Breaker Accessories

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-65

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

Siemens­/­Speedfax­ Previous­folio:­Murray­ SS­2/15/11

Circuit BreakersCircuit Breaker Accessories

Mechanical Interlock

ECQML12

Padlocking Device

ECPLD1R/2R/3R (Single pole pictured. 2-/3-pole available) ECQLD4 ECQTH4ECPLD2

ECPLD1 ECQLD3

Handle Tie

ECQTH3ECQTH2

Handle Blocking Device

ECBX231M

ECQL1

Main Breaker Retainer

ECMBR2

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-66

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

a All standard circuit breakers are calibrated to 40°C maxi-mum ambient application.

Type MD-T, MD-HT, MD-MT

Type MH-T Type MP-GT, MP-HGT, MP-ET, MP-HET

3"

23/8"

31/8"

1-Pole 2-Pole 3-Pole

Type MP-T, MP-HT, MP-MT

Type M1 Type M2

Type MPP-T, MPP-HT, MPP-MT, MPP-PTType MD-TR, MD-HTR, MD-MTR

Circuit BreakersLine Diagrams

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 1-67

1LO

AD

CENTERS &

CIRCU

IT BREA

KERS

Circuit Breaker TypeCircuit BreakerAmpere Rating

Cables PerConnector

ConnectorWire Range

LOAD SIDE

MP-T, MP-HT, MP-MT 10 1 or 2 #16–#14 CU

15–35 11

#14-#6 AWG Cu#14-#6 AWG Al

40–50 11

#8–#6 AWG Cu#8–#4 AWG Al

55–125 (exception: 1 & 2-pole MP-T at 55-60)

11

#8-#2/0 Cu #8-#2/0 Al

MP-T 1 & 2-Pole ONLY 55–60 1 #6-#4 AWG Cu-Al (#3 AWG requires MP-HT or MP-MT)

MH-T 15–35 11

#14-#6 AWG Cu#14-#6 AWG Al

40 1 #8 AWG CU-Al

40–50 11

#8–#6 AWG Cu#8–#4 AWG Al

MP-GT, MP-HGT, MP-ET, MP-HETBLF, BLHF, BLE, BLEH

15–30 11

#14–#10 AWG Cu#12–#8 AWG Al

40–60 11

#8–#6 AWG Cu#8–#4 AWG Al

MP-AT2, MP-HAT, BAF, BAFH 15–20 11

#14–#12 AWG Cu#12–#10 AWG Al

MSQ 15–20 2 #14-#10 AWG Cu only

15–20 11

#14–#12 AWG Cu#12–#10 AWG Al

25–35 11

#10–#8 AWG Cu#10–#6 AWG Al

40–60 11

#8–#6 AWG Cu#8–#4 AWG Al

MD-T, MD-HT, MD-MT, MD-PT, MD-TR, MD-HTR, MD-MTR, MD-PTR

150–200 1 #1–300kcmil Cu-Al

M1100

1 #4-3/0 AWG Cu #4-3/0 AWG Al

1 #4-3/0 AWG Cu #4-3/0 AWG Al

125 1 #4–3/0 AWG Cu-Al

M2 150 1 #1–300kcmil Cu-Al

200 1 #1–300kcmil Cu-Al

225 1 #1–300kcmil Cu-Al

MPP-T, MPP-HT, MPP-MT, MPP-PT 125 11

#1 AWG Cu#2/0 AWG Al

150 11

#1/0 AWG Cu#3/0 AWG Al

175 11

#2/0 AWG Cu#4/0 AWG Al

200 11

#3/0 AWG Cu250kcmil AWG Al

225 11

#4/0 AWG Cu300kcmil AWG Al

MQ, MQH, MQL 60–225 1 #6–300kcmil Cu#4–300kcmil Al

Siemens­/­Speedfax­ Previous­folio:­Murray­ SS­2/15/11

Circuit BreakersLug Data

Revised on 10/31/18

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog1-68

1LO

AD

CEN

TERS

&

CIRC

UIT

BRE

AKE

RS

Circuit BreakersNotes