Lo-Rad Presentation (CAREION)

9
RADIOGRAPHIC TESTING WITH LO-RAD EQUIPMENT

description

lorad presentation

Transcript of Lo-Rad Presentation (CAREION)

  • RADIOGRAPHIC TESTING WITH LO-RAD EQUIPMENT

  • Lo-Rad is a flexible system which fits any shape and size of steel or pipe work.Lo-Rad operates efficiently under varying temperature conditions -50 to 120 Degrees CelsiusLo-Rad system is easily attached to any specimen due to the patented self adhesive envelopesLo-Rad system allows you to use your existing and standard radiographic equipment, Techops 660, 880 Gammamat TI, TIF etc

    Lo-Rad Features

  • Complete System

    The case will hold the following

    Mazel mats with envelopesPrimary beam Mazel mats & envelopeMazel Outer and standard inner guide tubeCollimatorEllipse standFlash boxThe system is easily transported on site. The unit is waterproof and has castor wheels for maneuverability and storing.

  • Lo-Rad Mazel Mats

    915 x 305 x 9.5mm11.3kgLead equivalent of 3.3mmSpecificationsFlexible!!!

  • Self Adhesive Mats & Ellipse Stand For work on 2 Inch pipe work - DWDIAllows for required SFD

  • Mazel Guide Tube & Collimator

    39mm od 19 mm id 8 kgMax Temp 120 DegLength 1.5mSpecificationsTungsten CollimatorStandard Guide TubeMazel Guide Tube ShieldFlexible!

  • Mazel Flash Box

    Flash Box weight 11KgSpecifications

    The Mazel Flash Box is designed to reduce any flash radiation which might be emitted when the source is wound out

  • Step by StepStep 1Attach Guide Tube to Isotope/ContainerStep 2Insert Isotope/Container into Flash BoxStep 3Attach collimator to weld or specimenStep 4Enclose collimator and weld with Mazel MatsStep 5Expose Weld

  • CONTACTThank you for your time