LM-79-08 Test Report - RemPhos Technologies€¦ · NVLAP LAB CODE 201011-0 Report No.:...

16
NVLAP LAB CODE 201011-0 Report No.: GZE150867-C-P Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com 1 / 16 LM-79-08 Test Report For REMPHOS TECHNOLOGIES LLC (Brand Name: ) 90 Holten St, Danvers, MA 01923USA LED Lamp Model name(s): RPT-LEDBIAX-2000LM-3000K Representative (Tested) Model: RPT-LEDBIAX-2000LM-3000K Model Different: N/A Test & Report By: Review By: Peeta Cao Engineer: Peeta Cao Manager: Tommy Liang Date: Aug.24,2015 Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.

Transcript of LM-79-08 Test Report - RemPhos Technologies€¦ · NVLAP LAB CODE 201011-0 Report No.:...

NVLAP LAB CODE 201011-0

Report No.: GZE150867-C-P

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

1 / 16

LM-79-08 Test Report

For

REMPHOS TECHNOLOGIES LLC

(Brand Name: )

90 Holten St, Danvers, MA 01923,USA

LED Lamp

Model name(s): RPT-LEDBIAX-2000LM-3000K

Representative (Tested) Model: RPT-LEDBIAX-2000LM-3000K

Model Different: N/A

Test & Report By: Review By:

Peeta Cao

Engineer: Peeta Cao Manager: Tommy Liang

Date: Aug.24,2015

Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or

any agency of the Federal Government.

NVLAP LAB CODE 201011-0

Report No.: GZE150867-C-P

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

2 / 16

U.S. Department of Energy

Lighting FactsTM

Uniform LM-79 Reporting Template

Laboratory Information:

Name of Test Laboratory Standard-Tech Co., Ltd.

Date of Test Report Aug.24,2015

Test Report No. GZE150867-C-P

Laboratory Contact Name Tommy Liang

Product Information:

Organization Name REMPHOS TECHNOLOGIES LLC

Brand Name

Model Number RPT-LEDBIAX-2000LM-3000K

SKU (if available) N/A

Type of Luminaire

(for integral lamps, list base type and lamp type) LED Lamp

Luminaire Aperture (for downlights) -- in.

Luminaire Length -- mm

Luminaires Width -- mm

Number of Units (modular products) N/A s

Electrical Measurements:

Integrating Sphere

Output

Goniophotometer

Output

Input Wattage -- 20.75 W

Input Current -- 0.1745 A

Input Voltage (ac) -- 120.0 V

Power Factor -- 0.9911

Off-State Power -- 0 W

Photometric Characteristics

Total Initial Lumen Output -- 1836.5 lm

Initial Lumen Efficacy -- 88.51 lm/w

Correlated color temperature / CCT 2981 -- K

Color rendering index / CRI 83.4 --

R9 Value 10 --

Duv -0.0018 --

Luminous Intensity Distribution

Center beam candlepower (if applicable)

-----

599 cd

Beam angle (if applicable) 116.7 °

Zonal lumens in the 0°-60° zone 70.3 %

Zonal lumens in the 60°-90° zone 26.3 %

Zonal lumens in the 90°-120° zone 3 %

Zonal lumens in the 120°-180° zone 0.4 %

NVLAP LAB CODE 201011-0

Report No.: GZE150867-C-P

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

3 / 16

Test Specifications:

Date of Receipt : Aug.20,2015

Date of Test : Aug.22,2015

Test item : Total Luminous Flux, Luminous Distribution Intensity, Luminous

Efficacy, Correlated Color Temperature, Color Rendering Index,

Chromaticity Coordinate, Electrical parameters

Reference Standard IES LM-79-2008 Electrical and Photometric Measurements of Solid-State

Lighting Products

ANSI C78.377-2008 Specifications for the Chromaticity of Solid State

Lighting Products

CIE 13.3-1995 Method of Measuring and Specifying Colour Rendering

Properties of Light Sources

CIE 15-2004 Technical Report Colorimetry

IESNA LM-16-93 Practical Guide to Colorimetry of Light Source

IESNA TM-16-05 Technical Memorandum on Light Emitting Diode (LED)

Sources and Systems

Reference Work

Instruction

QD25

Test Methods

1. Photometric and Electrical measurements – Light Distribution Method:

Photometric parameters were measured using the goniophotometer and software. The ambient

temperature shall be maintained at 25° C ± 1° C, measured at a point not more than 1 m from the

sample and at the same height as the sample. The sample was operated at 120 Volts AC, 60Hz. It was

stabilized before measurement was made. Luminous flux, luminaire efficacy, zonal lumen were

calculated from the software taken at 1° vertical intervals and 22.5° horizontal intervals.

2. Photometric and Electrical Measurements – Integrating Sphere Method:

Photometric parameters were measured using an integrating sphere, a spectroradiometer and software.

The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C. The sample

measurements were made using a spectroradiometer connected by a fiber optic cable and detector

through the detector port of the integrating sphere. The sample was operated at 120 Volts AC, 60Hz. It

was stabilized before measurement was made. Chromaticity coordinates, correlated color temperature

and color rendering index were calculated from the spectral radiant flux measurements taken at least 5

nm intervals over the range of 380 to 780 nm.

NVLAP LAB CODE 201011-0

Report No.: GZE150867-C-P

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

4 / 16

1. Product Information:

Brand Name

Model Number RPT-LEDBIAX-2000LM-3000K

Luminaire Type LED Lamp

Rated Voltage / Frequency 100~ 277, 50/60Hz

Nominal Power 20W

Rated Initial Lamp Lumen --

Declared CCT 3000K

LED Manufacturer N/A

LED Model N/A

Sample Receipt Date Aug.20,2015

Sample Number GZE150867-C1(3000K)

Photo

NVLAP LAB CODE 201011-0

Report No.: GZE150867-C-P

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

5 / 16

2. Electrical, Photometric and Chromaticity Measurements

(Refer to Work Instruction QD25)

IES LM-79 2008

Test date 2015-08-22 Test Ambient: 25.2 º C

Test Orientation As intended Stabilization Time (min) 90

Model Number RPT-LEDBIAX-2000LM-3000K

Electrical Measurement:

Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD %

GZE150867

-C1

120.0 60 0.1745 20.75 0.9911 11.42

277.0 60 0.0833 21.02 0.9106 14.74

Sphere-Spectroradiometer Method :

Parameter Result Special Color Rendering Indices

Test Voltage (V) 120.0 R1 82 R9 10

Frequency (Hz) 60 R2 91 R10 79

Color Rendering Index (CRI) 83.4 R3 97 R11 83

R9 10 R4 82 R12 76

CCT (K) 2981 R5 82 R13 84

Chromaticity (x, y) x=0.4356 y=0.3991 R6 89 R14 99

Chromaticity (u’, v’) u'=0.2519 v'=0.5192 R7 83 R15 75

Duv -0.0018 R8 61 -- --

Goniophotometer Method :

Parameter Result

Test Voltage (V) 120.0

Frequency (Hz) 60

Total Luminous (lm) 1836.5

Luminous Efficacy (lm/W) 88.51

Beam Angle° 116.7

Center Beam Candle Power (cd) 599

Goniophotometer Method in :

Parameter Result

Test Voltage (V) 277.0

Frequency (Hz) 60

Total Luminous (lm) 1847

Luminous Efficacy (lm/W) 87.86

NVLAP LAB CODE 201011-0

Report No.: GZE150867-C-P

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

6 / 16

Spectral Power Distribution & Chromaticity Diagram

NVLAP LAB CODE 201011-0

Report No.: GZE150867-C-P

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

7 / 16

Zonal Lumen Tabulation

Zonal Lumen Summary

Zone Lumens % Luminaire

0-30 464.2 24%

0-40 760.6 39.3%

0-60 1,359.3 70.3%

60-90 509.3 26.3%

70-100 299.8 15.5%

90-120 57.8 3%

0-90 1,868.6 96.6%

90-180 64.8 3.4%

0-180 1,933.4 100%

Lumens Per Zone

Zone Lumens % Total Zone Lumens % Total

0-10 56.6 2.9% 90-100 27.8 1.4%

10-20 162.1 8.4% 100-110 19.3 1%

20-30 245.5 12.7% 110-120 10.7 0.6%

30-40 296.4 15.3% 120-130 4.5 0.2%

40-50 310.4 16.1% 130-140 1.6 0.1%

50-60 288.3 14.9% 140-150 0.5 0%

60-70 237.3 12.3% 150-160 0.3 0%

70-80 169.4 8.8% 160-170 0.2 0%

80-90 102.6 5.3% 170-180 0.1 0%

NVLAP LAB CODE 201011-0

Report No.: GZE150867-C-P

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

8 / 16

Photometric Data

Illuminance Plots

NVLAP LAB CODE 201011-0

Report No.: GZE150867-C-P

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

9 / 16

ISOCANDELA DIAGRAM

ISOLUX DIAGRAM

NVLAP LAB CODE 201011-0

Report No.: GZE150867-C-P

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

10 / 16

Candela Table - Type C

0 22.5 45 67.5 90 112.5 135 157.5 180 202.5 225 247.5 270 292.5 315 337.5 360

0 599 599 599 599 599 599 599 599 599 599 599 599 599 599 599 599 599

1 599 599 599 599 599 599 599 599 599 599 599 599 599 599 599 599 599

2 598 599 599 598 599 599 598 598 598 598 599 599 598 598 599 598 598

3 598 598 598 598 598 598 598 598 598 598 598 598 598 598 599 598 598

4 597 597 597 597 598 597 597 597 597 597 597 597 597 597 598 597 597

5 596 596 596 597 596 597 596 596 596 596 596 596 596 597 597 595 596

6 594 595 595 596 596 595 595 594 594 595 595 595 595 595 595 594 594

7 592 593 594 595 594 594 593 593 593 593 594 594 594 594 594 593 592

8 591 591 592 594 593 593 592 591 591 591 592 593 592 592 593 591 591

9 589 590 590 592 591 591 590 589 588 589 590 591 591 590 590 589 589

10 586 587 588 590 589 590 588 587 586 586 588 589 589 588 589 587 586

11 584 585 586 588 588 587 586 584 583 584 585 587 587 586 586 584 584

12 581 582 584 585 585 585 584 582 580 581 583 585 585 584 584 582 581

13 578 579 581 583 583 583 581 579 577 578 580 583 582 582 581 579 578

14 575 576 578 580 581 580 578 576 574 575 577 580 580 579 578 576 575

15 571 573 575 578 578 577 575 572 570 571 574 577 577 576 575 572 571

16 568 569 572 574 575 574 572 568 566 568 571 574 575 573 572 569 568

17 564 565 569 571 572 571 568 564 563 564 567 571 572 570 568 565 564

18 559 561 565 568 569 568 564 560 558 560 564 568 568 567 564 561 559

19 555 557 561 564 565 564 560 556 554 555 560 564 565 563 560 557 555

20 550 552 557 561 562 561 556 551 549 551 556 560 561 559 556 552 550

21 545 548 552 557 558 557 552 546 544 546 551 556 558 555 552 547 545

22 540 543 548 553 554 553 547 541 539 541 547 552 554 551 548 543 540

23 535 537 544 549 550 549 542 536 534 536 542 548 550 547 543 538 535

24 530 532 539 544 545 544 538 531 529 531 538 543 545 543 538 533 530

25 524 527 534 540 541 539 532 525 523 525 533 539 541 538 533 527 524

26 519 521 529 535 536 534 527 520 517 520 528 534 536 533 528 522 519

27 513 516 524 530 532 529 522 514 511 514 522 529 532 528 522 516 513

28 507 510 518 525 527 524 516 508 505 508 517 524 527 523 516 510 507

NVLAP LAB CODE 201011-0

Report No.: GZE150867-C-P

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

11 / 16

29 500 504 513 519 522 519 510 502 499 502 511 518 522 518 511 504 500

30 494 498 507 514 517 513 504 496 492 495 505 513 516 513 505 498 494

31 487 491 501 508 512 508 498 489 486 489 499 508 511 507 499 491 487

32 481 484 495 503 506 502 492 483 479 482 493 502 506 502 493 484 481

33 474 478 488 497 501 496 486 476 472 476 486 496 500 496 486 478 474

34 467 471 482 492 495 490 479 469 465 469 480 490 494 490 480 471 467

35 460 464 475 485 490 484 473 462 458 462 473 485 488 483 473 464 460

36 453 457 469 479 483 478 466 455 451 455 466 478 482 477 466 457 453

37 445 450 462 473 478 472 459 448 443 447 459 472 476 471 460 450 445

38 438 443 455 467 472 466 452 440 435 440 452 466 470 464 453 442 438

39 430 435 448 461 466 460 445 432 428 432 445 459 464 458 446 435 430

40 423 428 441 454 459 453 438 425 420 425 438 452 457 451 439 427 423

41 415 420 434 448 453 446 431 417 412 417 431 446 451 445 431 419 415

42 406 412 426 441 446 440 423 410 404 409 424 439 445 438 424 411 406

43 398 404 419 434 440 433 415 402 396 401 416 432 438 431 417 403 398

44 390 396 411 427 433 426 408 394 387 393 409 425 431 424 409 395 390

45 381 388 403 420 426 419 400 385 379 385 401 418 424 417 402 387 381

46 373 380 396 413 420 412 392 377 370 377 393 411 418 410 394 379 373

47 364 371 388 406 413 405 384 368 361 368 385 404 411 403 386 370 364

48 355 363 380 399 406 398 377 360 353 360 378 396 404 396 378 362 355

49 347 354 372 391 399 390 369 351 344 351 369 389 396 389 370 354 347

50 338 346 364 384 392 383 361 343 335 343 362 381 389 381 362 345 338

51 329 337 356 376 385 376 353 334 326 334 354 374 382 374 354 336 329

52 320 328 348 369 378 368 345 325 317 325 345 366 375 366 346 328 320

53 311 319 340 362 370 361 337 316 308 316 338 359 368 359 338 319 311

54 302 310 332 354 363 354 329 307 298 308 329 351 361 352 330 310 302

55 293 302 324 346 356 346 321 298 289 298 321 344 354 344 322 301 293

56 283 293 315 339 349 339 313 289 280 289 313 336 346 337 314 292 283

57 274 283 307 331 342 331 305 280 270 280 305 329 339 329 306 283 274

58 264 274 299 324 334 324 297 271 261 271 297 321 332 322 298 274 264

59 255 265 291 316 327 316 289 262 252 262 289 313 325 314 289 264 255

60 245 256 283 309 320 309 281 252 242 253 280 306 318 307 281 255 245

NVLAP LAB CODE 201011-0

Report No.: GZE150867-C-P

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

12 / 16

61 236 247 274 301 313 301 273 244 232 244 272 298 310 299 273 246 236

62 226 238 266 293 305 294 265 235 223 234 264 290 303 292 265 237 226

63 217 228 258 286 298 286 257 226 213 225 256 282 296 285 257 228 217

64 207 219 250 278 291 279 249 216 203 216 248 274 289 277 248 219 207

65 197 210 242 271 284 272 241 207 194 207 240 267 281 270 240 210 197

66 187 201 234 263 277 264 233 198 184 198 231 259 274 263 232 201 187

67 178 192 226 256 270 257 225 189 174 189 223 251 267 255 224 191 178

68 168 183 218 249 262 250 217 180 164 179 216 244 260 248 216 182 168

69 158 174 210 242 255 243 209 171 155 170 208 237 253 241 209 173 158

70 148 165 202 235 248 236 201 163 145 161 200 230 246 233 201 164 148

71 139 156 195 227 242 229 194 154 135 153 192 223 239 226 193 156 139

72 129 148 187 221 235 222 187 145 125 144 184 217 232 219 186 147 129

73 119 139 180 214 228 215 179 136 115 135 176 211 225 212 178 138 119

74 109 131 172 207 221 208 172 128 106 127 169 204 219 205 171 130 109

75 100 122 165 201 215 201 165 120 96 118 162 198 212 198 164 122 100

76 91 114 158 194 208 194 158 112 87 110 155 192 205 192 157 114 91

77 81 106 151 187 201 188 151 105 78 102 147 185 199 185 150 106 81

78 72 98 144 181 195 181 144 97 69 95 140 179 192 179 143 98 72

79 63 91 137 174 189 175 137 90 60 87 133 172 186 173 136 90 63

80 54 84 131 168 182 168 131 83 51 80 126 166 180 166 130 83 54

81 46 77 125 161 176 162 125 76 43 73 120 160 173 160 123 76 46

82 38 70 119 154 170 156 119 69 35 67 114 153 168 154 117 70 38

83 30 64 113 148 164 150 112 63 28 60 109 147 162 148 111 64 30

84 24 58 108 142 158 144 106 57 21 54 104 141 155 142 106 58 24

85 17 52 102 136 152 138 101 52 15 49 99 135 150 137 100 52 17

86 12 47 96 131 146 132 95 47 10 44 93 130 144 131 95 47 12

87 7 43 91 126 141 127 90 42 5 39 88 124 138 126 89 42 7

88 3 38 85 120 135 121 85 37 2 35 82 119 133 120 84 38 3

89 1 34 80 115 130 116 80 33 0 31 77 114 127 115 79 34 1

90 0 30 75 110 124 111 75 29 0 27 73 108 122 109 74 30 0

91 0 27 71 105 119 106 70 24 0 22 68 103 117 104 69 26 0

92 0 16 67 101 114 101 66 5 0 7 63 99 112 99 65 11 0

NVLAP LAB CODE 201011-0

Report No.: GZE150867-C-P

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

13 / 16

93 0 2 58 96 110 96 42 0 0 0 27 91 106 92 41 0 0

94 0 0 5 79 99 72 0 0 0 0 0 47 74 51 0 0 0

95 0 2 0 11 45 4 0 5 0 3 0 0 4 1 0 4 0

96 0 4 0 1 0 0 0 6 0 5 0 0 0 0 0 5 0

97 0 5 0 0 0 0 0 6 0 5 1 0 0 0 0 6 0

98 0 5 2 0 0 0 6 5 0 4 20 1 0 0 13 5 0

99 0 4 24 0 0 0 25 4 0 3 23 1 0 0 23 4 0

100 0 4 24 1 0 3 23 4 0 3 22 11 0 9 22 4 0

101 0 4 23 26 3 31 22 4 0 3 21 43 23 42 22 4 0

102 0 4 22 42 35 43 21 3 0 3 20 40 55 41 21 3 0

103 0 3 20 40 53 40 20 3 0 2 19 38 53 39 20 3 0

104 0 3 19 38 51 39 19 3 0 2 18 36 50 37 19 3 0

105 0 3 18 36 49 37 18 2 0 2 16 34 48 35 17 3 0

106 0 2 17 34 47 35 17 2 0 1 15 32 45 33 16 2 0

107 0 2 16 32 44 33 16 2 0 1 14 31 43 32 15 2 0

108 0 2 15 31 42 31 15 1 0 1 13 29 40 30 14 2 0

109 0 1 13 29 40 29 13 1 0 1 12 28 38 29 13 1 0

110 0 1 13 27 37 28 13 1 0 1 11 27 36 27 12 1 0

111 0 1 12 26 35 27 11 1 0 0 10 25 34 26 11 1 0

112 0 1 11 25 33 25 11 1 0 0 10 24 32 24 10 1 0

113 0 1 10 23 31 24 10 0 0 0 9 22 30 23 10 1 0

114 0 1 9 22 29 22 9 0 0 0 8 21 28 21 9 1 0

115 0 1 8 21 28 21 8 0 0 0 7 19 26 20 8 1 0

116 0 0 8 19 26 19 8 0 0 0 7 18 24 19 7 0 0

117 0 0 7 18 24 18 7 0 0 0 6 17 23 18 7 0 0

118 0 0 6 17 23 17 6 0 0 0 6 16 21 16 6 0 0

119 0 0 6 16 21 16 6 0 0 0 5 15 20 15 6 0 0

120 0 0 5 15 20 15 5 0 0 0 5 14 19 14 5 0 0

121 0 0 5 14 18 14 5 0 0 0 4 13 17 13 5 0 0

122 0 0 4 13 17 13 4 0 0 0 4 12 16 12 4 0 0

123 0 0 4 12 16 12 4 0 0 0 3 11 15 11 4 0 0

124 0 0 4 11 15 11 4 0 0 0 3 10 14 11 4 0 0

NVLAP LAB CODE 201011-0

Report No.: GZE150867-C-P

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

14 / 16

125 0 0 3 10 13 10 3 0 0 0 3 9 13 10 3 0 0

126 0 0 3 9 12 9 3 0 0 1 3 8 12 9 3 0 0

127 0 0 3 8 11 8 3 0 0 1 2 8 11 8 3 0 0

128 0 0 3 8 10 8 2 0 0 1 2 7 10 7 2 0 0

129 0 0 3 7 9 7 2 0 1 1 2 6 9 7 2 0 0

130 0 0 2 6 9 6 2 0 0 1 1 6 8 6 2 0 0

131 0 0 2 6 8 6 2 0 1 1 1 5 7 6 2 0 0

132 0 0 2 5 7 5 1 0 1 1 1 5 7 5 1 0 0

133 0 0 2 5 6 5 1 0 1 1 1 4 6 5 1 0 0

134 0 0 1 4 6 4 1 0 1 1 1 4 6 4 1 0 0

135 0 0 1 4 5 4 1 0 1 1 1 3 5 4 1 0 0

136 0 0 1 3 5 3 1 0 1 1 0 3 5 3 1 0 0

137 0 0 1 3 4 3 0 0 1 1 0 2 4 3 1 0 0

138 0 0 1 3 4 2 0 0 1 1 0 2 4 3 1 0 0

139 0 0 1 3 3 2 1 0 1 1 0 2 3 2 0 0 0

140 0 0 1 2 3 2 0 0 1 1 0 2 3 2 0 0 0

141 0 0 1 2 2 2 0 0 1 1 0 1 2 2 0 0 0

142 0 0 0 2 2 1 0 0 1 1 0 1 2 1 0 0 0

143 0 0 0 2 2 1 0 0 1 1 0 1 2 1 0 0 0

144 0 0 0 1 2 1 0 0 1 1 0 1 2 1 0 0 0

145 0 0 0 1 1 1 0 0 1 1 1 1 1 1 0 0 0

146 0 0 0 1 1 1 0 0 1 1 1 1 1 1 0 1 0

147 0 0 0 1 1 1 0 0 1 1 1 1 1 1 0 0 0

148 0 0 0 1 1 0 0 0 1 1 1 1 1 0 0 0 0

149 0 0 0 1 1 0 0 0 1 1 1 1 1 0 0 0 0

150 0 0 0 1 0 0 1 0 1 1 1 1 0 0 0 0 0

151 1 0 0 0 0 0 1 0 1 1 1 1 0 0 0 0 1

152 0 0 0 0 0 0 1 0 1 1 1 1 0 0 1 0 0

153 0 0 0 0 0 0 1 0 1 1 1 1 0 0 1 0 0

154 0 0 0 0 0 0 1 0 1 1 1 1 0 0 0 0 0

155 1 0 0 0 0 0 1 0 1 1 1 1 0 0 0 0 1

156 1 0 0 0 0 0 1 1 1 1 1 1 0 0 1 0 1

NVLAP LAB CODE 201011-0

Report No.: GZE150867-C-P

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

15 / 16

157 1 1 0 0 0 0 1 1 1 1 1 1 0 0 1 0 1

158 1 0 0 0 1 0 1 1 1 1 1 1 0 0 1 0 1

159 1 0 0 0 0 0 1 1 1 1 1 1 0 0 1 0 1

160 1 0 0 0 0 0 1 1 1 1 1 1 0 0 1 0 1

161 1 0 0 0 0 0 0 1 1 1 1 1 0 0 1 0 1

162 1 0 0 0 0 0 0 1 1 1 1 1 0 0 1 0 1

163 1 0 0 0 0 0 0 1 1 1 1 1 0 0 1 0 1

164 1 0 0 0 0 0 0 1 1 1 1 1 0 0 1 0 1

165 1 0 0 0 0 0 0 1 1 1 1 1 0 0 1 0 1

166 1 0 0 0 0 0 0 1 1 1 1 1 0 0 1 0 1

167 1 1 0 0 0 0 0 1 1 1 1 1 0 0 1 0 1

168 1 1 0 0 1 0 0 1 1 1 1 1 0 0 1 0 1

169 1 1 0 0 1 0 0 1 1 1 1 1 0 0 1 0 1

170 1 1 1 0 1 0 0 1 1 1 1 1 0 0 1 0 1

171 1 1 1 0 1 0 0 1 1 1 1 1 0 0 1 0 1

172 1 1 1 0 1 0 0 1 1 1 1 1 0 0 1 1 1

173 1 1 1 0 1 0 0 1 1 1 1 1 0 0 1 1 1

174 1 1 1 1 1 0 0 1 1 1 1 1 0 0 1 1 1

175 1 1 1 1 1 0 0 1 1 1 1 1 0 0 1 1 1

176 1 1 1 1 1 0 0 1 1 1 1 1 0 0 1 1 1

177 1 1 1 1 1 0 0 1 1 1 1 1 0 0 1 1 1

178 1 1 1 1 1 0 0 1 1 1 1 1 0 0 1 1 1

179 1 1 1 1 1 0 0 1 1 1 1 1 0 0 1 1 1

180 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

NVLAP LAB CODE 201011-0

Report No.: GZE150867-C-P

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

16 / 16

3. Test Equipment

Equipment ID Equipment Name Last Calibration Date Next Calibration Date

ST-R-336 2 meter Integrating Sphere 2015-07-01 2016-06-30

ST-R-331 Spectral analysis system HAAS-2000 2015-07-01 2016-06-30

D204 Standard Lamp 2015-07-01 2016-06-30

PF2010 Power Meter for Integrating Sphere 2015-07-01 2016-06-30

EE-09 Goniophotometer system 2015-07-01 2016-06-30

D908S Standard Lamp 2015-07-01 2016-06-30

PF210 Power Meter for Goniophotometer 2015-07-01 2016-06-30

ST-R-181A Temperature Tester 2015-07-01 2016-06-30

Uncertainty

Photometric Measurement (Sphere):1.74%

Chromaticity Measurement(Sphere):14.3K

Photometric Measurement(Goniophotometer):1.62%

****** END OF DATASHEET PACKAGE ******