NVLAP LAB CODE 201011-0
Report No.: GZE160226-A
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
1 / 17
LM-79-08 Test Report
For
Venture Lighting International,Inc
(Brand Name: N/A)
7905 Cochran Road,Ste 300Glenwillow,Ohino 44139,USA
LED Lamp
Model name(s): OR100-40E39
Model differences: N/A
Test & Report By: Review By:
Johnson Sun
Engineer: Johnson Sun Manager: Tommy Liang
Date:Feb.26, 2016
Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or
any agency of the Federal Government.
NVLAP LAB CODE 201011-0
Report No.: GZE160226-A
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
2 / 17
U.S. Department of Energy
Lighting FactsTM
Uniform LM-79 Reporting Template
Laboratory Information:
Name of Test Laboratory Standard-Tech Co., Ltd.
Date of Test Report Feb.26, 2016
Test Report No. GZE160226-A
Laboratory Contact Name Tommy Liang
Product Information:
Organization Name Venture Lighting International,Inc
Brand Name N/A
Model Number OR100-40E39
SKU (if available) N/A
Type of Luminaire
(for integral lamps, list base type and lamp type) LED Lamp
Luminaire Aperture (for downlights) -- in.
Luminaire Length -- mm
Luminaires Width -- mm
Number of Units (modular products) N/A s
Electrical Measurements:
Integrating Sphere
Output
Goniophotometer
Output
Input Wattage -- 101.5 W
Input Current -- 0.8508 A
Input Voltage (ac) -- 120.0 V
Power Factor -- 0.9941
Off-State Power -- 0 W
Photometric Characteristics
Total Luminous (lm) -- 11123 lm
Luminous Efficacy (lm/W) -- 109.61 lm/w
Correlated color temperature / CCT 4109 -- K
Color rendering index / CRI 83.4 --
R9 Value 9 --
Duv 0.0010 --
Luminous Intensity Distribution
Center beam candlepower (if applicable) -- 382 cd
Beam angle (if applicable) -- 265.9 °
Zonal lumens in the 0°-60° zone -- 28.6 %
Zonal lumens in the 60°-90° zone -- 37.8 %
Zonal lumens in the 90°-120° zone -- 23.5 %
Zonal lumens in the 120°-180° zone -- 10.1 %
NVLAP LAB CODE 201011-0
Report No.: GZE160226-A
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
3 / 17
Test Specifications:
Date of Receipt : Nov.27,2015
Date of Test : Feb.24,2016
Test item : Total Luminous Flux, Luminous Distribution Intensity, Luminous
Efficacy, Correlated Color Temperature, Color Rendering Index,
Chromaticity Coordinate, Electrical parameters
Reference Standard IES LM-79-2008 Electrical and Photometric Measurements of Solid-State
Lighting Products
ANSI C78.377-2008 Specifications for the Chromaticity of Solid State
Lighting Products
CIE 13.3-1995 Method of Measuring and Specifying Colour Rendering
Properties of Light Sources
CIE 15-2004 Technical Report Colorimetry
IESNA LM-16-93 Practical Guide to Colorimetry of Light Source
IESNA TM-16-05 Technical Memorandum on Light Emitting Diode (LED)
Sources and Systems
Reference Work
Instruction
QD25
Test Methods
1. Photometric and Electrical Measurements – Integrating Sphere Method:
Photometric parameters were measured using an integrating sphere, a spectroradiometer and software.
The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C. The sample
measurements were made using a spectroradiometer connected by a fiber optic cable and detector
through the detector port of the integrating sphere. The sample was operated at 120 Volts AC, 60Hz. It
was stabilized before measurement was made. Chromaticity coordinates, correlated color temperature
and color rendering index were calculated from the spectral radiant flux measurements taken at least 5
nm intervals over the range of 380 to 780 nm.
2. Photometric and Electrical Measurements – Integrating Sphere Method:
Photometric parameters were measured using an integrating sphere, a spectroradiometer and software.
The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C. The sample
measurements were made using a spectroradiometer connected by a fiber optic cable and detector
through the detector port of the integrating sphere. The sample was operated at 120 Volts AC, 60Hz. It
was stabilized before measurement was made. Chromaticity coordinates, correlated color temperature
and color rendering index were calculated from the spectral radiant flux measurements taken at least 5
nm intervals over the range of 380 to 780 nm.
NVLAP LAB CODE 201011-0
Report No.: GZE160226-A
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
4 / 17
1. Product Information:
Brand Name N/A
Model Number OR100-40E39
Luminaire Type LED Lamp
Rated Voltage / Frequency 100 ~ 277Vac, 50/60Hz
Nominal Power 100W
Rated Initial Lamp Lumen N/A
Declared CCT 4000K
LED Manufacturer Guangzhou Hongli Opto-Electronic Co., Ltd.
LED Model HL-A-2835HW-S1-08-HR3
Sample Receipt Date Nov.27,2015
Sample Number GZE160226-A1
Photo
NVLAP LAB CODE 201011-0
Report No.: GZE160226-A
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
5 / 17
2.1 Electrical, Photometric and Chromaticity Measurements
(Refer to Work Instruction QD25)
IES LM-79 2008
Test date 2016-02-24 Test Ambient: 25.1º C
Test Orientation As intended Stabilization Time (min) 90
Model Number OR100-40E39
Electrical Measurement:
Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD %
GZE160226
-A1
120.0 60 0.8508 101.5 0.9941 9.74
277.1 60 0.3920 99.80 0.9188 13.55
Sphere-Spectroradiometer Method:
Parameter Result Special Color Rendering Indices
Test Voltage (V) 120.0 R1 82 R9 9
Frequency (Hz) 60 R2 91 R10 78
Color Rendering Index (CRI) 83.4 R3 96 R11 79
R9 9 R4 81 R12 61
CCT (K) 4109 R5 82 R13 84
Chromaticity (x, y) x=0.3764 y=0.3763 R6 87 R14 98
Chromaticity (u’, v’) u'=0.2226 v'=0.5008 R7 85 R15 76
Duv 0.0010 R8 64 -- --
Goniophotometer Method:
Parameter Result
Test Voltage (V) 120.0
Frequency (Hz) 60
Total Luminous (lm) 11123
Luminous Efficacy (lm/W) 109.61
Beam Angle° 265.9
Center Beam Candle Power (cd) 382
Goniophotometer Method:
Parameter Result
Test Voltage (V) 277.0
Frequency (Hz) 60
Total Luminous (lm) 11088
Luminous Efficacy (lm/W) 111.11
NVLAP LAB CODE 201011-0
Report No.: GZE160226-A
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
6 / 17
Spectral Power Distribution & Chromaticity Diagram
NVLAP LAB CODE 201011-0
Report No.: GZE160226-A
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
7 / 17
Zonal Lumen Tabulation:
Zonal Lumen Summary
Zone Lumens % Luminaire
0-30 538.1 4.8%
0-40 1,146.6 10.3%
0-60 3,176.4 28.6%
60-90 4,207.7 37.8%
70-100 3,911.6 35.2%
90-120 2,617.1 23.5%
0-90 7,384.1 66.4%
90-180 3,740.1 33.6%
0-180 11,124.2 100%
Lumens Per Zone
Zone Lumens % Total Zone Lumens % Total
0-10 38.9 0.3% 90-100 1,031.0 9.3%
10-20 151.9 1.4% 100-110 836.1 7.5%
20-30 347.3 3.1% 110-120 750.1 6.7%
30-40 608.5 5.5% 120-130 558.4 5%
40-50 887.3 8.0% 130-140 325.5 2.9%
50-60 1,142.6 10.3% 140-150 159.3 1.4%
60-70 1,327.1 11.9% 150-160 68.1 0.6%
70-80 1,430.0 12.9% 160-170 11.0 0.1%
80-90 1,450.7 13.0% 170-180 0.8 0%
NVLAP LAB CODE 201011-0
Report No.: GZE160226-A
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
8 / 17
Photometric Data
Illuminance Plots
NVLAP LAB CODE 201011-0
Report No.: GZE160226-A
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
9 / 17
ISOCANDELA DIAGRAM
ISOLUX DIAGRAM
NVLAP LAB CODE 201011-0
Report No.: GZE160226-A
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
10 / 17
Candela Table - Type C
0 22.5 45 67.5 90 112.5 135 157.5 180 202.5 225 247.5 270 292.5 315 337.5 360
0 382 382 382 382 382 382 382 382 382 382 382 382 382 382 382 382 382
1 382 382 382 381 382 382 382 382 382 382 382 382 382 380 381 381 382
2 384 382 381 381 382 382 380 383 384 383 382 383 383 382 380 382 384
3 385 384 383 384 384 382 384 385 386 385 385 385 385 384 385 384 385
4 387 387 387 387 386 386 387 386 388 389 388 388 389 388 388 387 387
5 391 390 390 390 391 391 390 390 391 394 393 394 394 393 392 392 391
6 397 396 396 397 397 397 395 397 399 399 398 401 401 398 397 397 397
7 404 403 403 405 403 403 403 405 407 408 408 408 409 407 405 404 404
8 412 412 412 413 412 412 413 413 417 418 418 417 419 416 414 413 412
9 423 423 422 424 425 423 423 424 426 429 429 430 431 427 422 422 423
10 436 436 435 436 436 435 433 438 439 442 440 444 445 440 435 435 436
11 449 449 449 451 449 450 450 452 455 456 457 460 458 455 452 447 449
12 463 463 466 466 466 462 465 467 470 472 473 476 474 470 467 462 463
13 479 479 482 481 483 481 483 487 486 488 491 494 490 486 483 479 479
14 495 498 500 498 501 500 501 506 503 505 510 512 509 505 503 496 495
15 512 517 521 519 519 519 522 524 523 525 530 532 526 523 521 514 512
16 530 534 542 540 538 537 543 544 540 543 550 552 544 540 541 533 530
17 551 554 562 560 559 557 564 566 559 563 571 574 567 560 564 554 551
18 572 575 584 582 581 579 587 588 582 586 592 596 588 582 585 577 572
19 594 597 606 605 604 603 609 611 605 610 613 618 607 603 607 599 594
20 615 619 626 627 626 627 631 635 626 632 635 642 629 625 628 621 615
21 637 639 646 650 650 651 654 660 650 654 658 666 650 646 650 645 637
22 662 662 668 675 675 675 676 682 675 679 681 691 675 668 672 669 662
23 688 684 689 698 701 699 697 704 701 704 702 713 698 690 695 691 688
24 713 708 710 720 726 722 719 726 728 725 722 733 722 711 716 713 713
25 738 731 730 742 752 743 739 747 753 747 741 756 748 733 737 735 738
26 764 754 752 765 779 764 760 768 779 769 761 778 774 755 759 759 764
27 794 776 773 791 806 787 782 789 807 793 782 800 800 778 779 782 794
NVLAP LAB CODE 201011-0
Report No.: GZE160226-A
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
11 / 17
28 823 798 795 814 835 811 804 813 838 818 803 823 828 801 799 807 823
29 851 820 816 839 865 836 823 836 866 842 824 847 855 824 818 830 851
30 879 842 837 861 895 860 844 856 897 866 845 867 879 844 838 852 879
31 906 864 858 882 925 882 864 876 925 887 866 887 902 865 859 873 906
32 931 885 877 903 952 902 882 894 951 906 884 908 925 884 879 894 931
33 955 905 897 925 980 922 902 915 978 927 904 928 948 904 898 916 955
34 980 927 915 948 1006 942 921 935 1005 947 923 948 970 923 916 936 980
35 1002 950 932 969 1032 961 940 953 1029 967 941 967 991 941 935 956 1002
36 1023 966 948 990 1057 980 959 971 1054 985 960 988 1011 958 953 976 1023
37 1043 987 967 1011 1081 999 978 990 1078 1003 978 1010 1029 975 972 995 1043
38 1063 1005 984 1032 1102 1018 997 1007 1100 1022 996 1031 1049 992 988 1013 1063
39 1081 1023 1002 1052 1122 1035 1013 1026 1123 1040 1015 1050 1065 1009 1005 1033 1081
40 1099 1042 1019 1073 1140 1052 1030 1045 1143 1059 1033 1069 1082 1027 1022 1052 1099
41 1115 1061 1037 1090 1157 1069 1049 1064 1161 1075 1052 1088 1098 1044 1038 1070 1115
42 1132 1078 1054 1110 1173 1086 1067 1081 1179 1090 1069 1107 1114 1061 1054 1087 1132
43 1147 1096 1071 1129 1189 1101 1087 1098 1196 1105 1089 1124 1129 1077 1071 1103 1147
44 1161 1113 1088 1150 1203 1117 1105 1115 1210 1118 1108 1141 1143 1094 1089 1123 1161
45 1175 1129 1104 1166 1218 1132 1124 1133 1225 1131 1127 1158 1158 1110 1105 1139 1175
46 1188 1146 1120 1183 1231 1147 1142 1148 1242 1144 1142 1175 1172 1126 1121 1156 1188
47 1202 1161 1136 1201 1245 1161 1159 1163 1255 1158 1158 1190 1184 1140 1134 1172 1202
48 1214 1175 1152 1218 1258 1175 1175 1178 1269 1171 1171 1206 1198 1154 1146 1187 1214
49 1226 1190 1166 1232 1270 1189 1192 1192 1281 1184 1184 1222 1211 1167 1155 1203 1226
50 1239 1203 1178 1247 1282 1203 1206 1204 1294 1197 1194 1237 1223 1181 1165 1216 1239
51 1251 1216 1190 1262 1293 1217 1218 1218 1304 1209 1205 1250 1235 1194 1176 1231 1251
52 1262 1228 1202 1274 1306 1229 1229 1229 1313 1220 1214 1264 1246 1206 1188 1244 1262
53 1273 1241 1214 1287 1315 1241 1240 1240 1322 1232 1222 1277 1256 1219 1198 1256 1273
54 1283 1254 1224 1300 1326 1253 1251 1253 1331 1245 1233 1288 1266 1231 1208 1269 1283
55 1292 1265 1237 1314 1337 1268 1263 1267 1340 1256 1243 1301 1276 1246 1220 1282 1292
56 1301 1278 1246 1324 1344 1279 1271 1280 1349 1266 1249 1314 1288 1261 1232 1297 1301
57 1312 1287 1256 1334 1351 1289 1278 1291 1359 1276 1259 1324 1297 1273 1245 1308 1312
58 1321 1295 1263 1345 1360 1300 1280 1299 1364 1284 1268 1335 1304 1283 1253 1319 1321
NVLAP LAB CODE 201011-0
Report No.: GZE160226-A
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
12 / 17
59 1327 1304 1269 1354 1366 1307 1281 1303 1371 1294 1275 1344 1310 1291 1259 1328 1327
60 1333 1313 1276 1362 1371 1316 1282 1309 1377 1302 1279 1350 1314 1299 1265 1335 1333
61 1339 1318 1278 1368 1375 1321 1281 1316 1381 1305 1280 1356 1318 1305 1271 1343 1339
62 1341 1322 1279 1375 1378 1325 1283 1324 1382 1310 1280 1362 1321 1309 1274 1349 1341
63 1344 1326 1280 1379 1382 1330 1287 1329 1382 1314 1285 1368 1324 1317 1278 1354 1344
64 1346 1332 1282 1384 1386 1333 1289 1333 1383 1319 1290 1373 1327 1323 1283 1357 1346
65 1348 1338 1286 1388 1388 1339 1290 1338 1387 1325 1292 1377 1329 1331 1287 1362 1348
66 1351 1344 1288 1392 1389 1344 1293 1342 1389 1328 1292 1382 1333 1337 1291 1365 1351
67 1353 1349 1289 1396 1391 1349 1295 1345 1391 1329 1295 1387 1334 1341 1294 1370 1353
68 1357 1350 1290 1400 1396 1354 1296 1348 1393 1333 1298 1389 1336 1345 1298 1371 1357
69 1359 1352 1289 1402 1398 1357 1296 1351 1396 1336 1299 1392 1339 1350 1303 1373 1359
70 1362 1354 1289 1405 1397 1359 1296 1352 1395 1336 1300 1394 1339 1355 1308 1375 1362
71 1362 1356 1290 1407 1396 1361 1296 1355 1394 1337 1303 1398 1339 1359 1309 1376 1362
72 1360 1359 1292 1409 1396 1365 1295 1355 1394 1339 1304 1400 1337 1362 1310 1378 1360
73 1361 1361 1291 1413 1396 1365 1297 1357 1394 1339 1303 1401 1335 1362 1312 1379 1361
74 1360 1360 1291 1412 1398 1365 1296 1361 1395 1340 1303 1400 1336 1365 1316 1382 1360
75 1359 1359 1291 1413 1396 1365 1296 1360 1393 1338 1301 1400 1334 1366 1316 1378 1359
76 1355 1356 1287 1410 1393 1364 1294 1358 1391 1336 1300 1401 1331 1363 1314 1377 1355
77 1352 1355 1284 1410 1392 1364 1291 1357 1387 1334 1298 1399 1329 1363 1312 1375 1352
78 1351 1353 1282 1407 1389 1361 1288 1357 1385 1333 1298 1398 1328 1363 1312 1373 1351
79 1349 1352 1281 1406 1386 1360 1284 1355 1381 1329 1296 1396 1325 1362 1311 1373 1349
80 1349 1350 1278 1405 1383 1358 1281 1354 1380 1327 1293 1395 1325 1361 1311 1372 1349
81 1347 1349 1275 1402 1380 1355 1277 1351 1379 1325 1290 1392 1319 1359 1307 1371 1347
82 1345 1346 1271 1399 1379 1352 1273 1348 1376 1324 1286 1390 1317 1357 1304 1367 1345
83 1343 1343 1269 1395 1376 1350 1269 1347 1374 1323 1284 1387 1315 1355 1303 1366 1343
84 1341 1342 1266 1394 1374 1346 1265 1347 1372 1322 1282 1386 1315 1353 1302 1365 1341
85 1342 1342 1265 1391 1372 1343 1263 1346 1373 1322 1281 1384 1316 1352 1302 1366 1342
86 1341 1342 1263 1389 1371 1341 1262 1346 1373 1321 1279 1382 1315 1351 1301 1365 1341
87 1337 1338 1259 1386 1370 1339 1260 1344 1369 1318 1277 1380 1312 1348 1296 1360 1337
88 1329 1330 1254 1382 1370 1336 1255 1336 1360 1307 1269 1376 1308 1344 1288 1352 1329
89 1316 1315 1241 1374 1367 1325 1238 1307 1344 1286 1247 1361 1299 1328 1272 1337 1316
NVLAP LAB CODE 201011-0
Report No.: GZE160226-A
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
13 / 17
90 1299 1290 1215 1337 1323 1276 1189 1216 1273 1221 1195 1307 1254 1283 1237 1291 1299
91 1208 1200 1162 1284 1272 1225 1115 1093 1160 1100 1120 1246 1205 1228 1163 1174 1208
92 1091 1076 1087 1229 1221 1175 1047 965 1044 975 1046 1180 1151 1164 1092 1048 1091
93 973 951 1019 1171 1169 1118 977 849 926 859 976 1123 1095 1105 1016 916 973
94 878 852 945 1113 1117 1058 906 824 888 822 900 1067 1042 1050 942 852 878
95 853 832 875 1052 1066 999 832 803 859 800 828 1008 990 991 866 834 853
96 833 816 803 989 1013 941 776 787 848 794 771 949 939 932 808 819 833
97 822 804 752 932 959 889 730 777 838 780 730 890 903 873 760 808 822
98 820 791 712 879 945 836 696 764 828 765 702 836 900 816 728 798 820
99 810 777 689 824 938 786 666 751 808 756 684 786 897 764 706 786 810
100 796 769 670 773 933 741 642 809 796 784 660 742 893 718 688 795 796
101 785 844 648 729 925 699 615 918 840 891 642 699 887 680 666 895 785
102 876 955 631 691 920 663 588 1025 947 999 631 662 882 641 648 1006 876
103 978 1068 614 657 913 629 562 1091 1052 1080 605 628 876 606 630 1117 978
104 1082 1105 591 626 912 598 525 1088 1138 1068 578 599 869 580 600 1122 1082
105 1114 1088 568 594 910 563 510 1077 1124 1058 566 570 865 555 577 1105 1114
106 1096 1074 555 566 908 530 499 1061 1112 1045 575 546 864 532 573 1091 1096
107 1084 1061 569 550 898 507 516 1039 1099 1020 604 523 861 509 588 1077 1084
108 1072 1040 608 524 889 475 561 1012 1083 996 657 500 851 486 634 1056 1072
109 1057 1016 653 506 881 456 607 996 1059 978 694 476 842 464 676 1032 1057
110 1036 997 699 489 874 437 645 977 1039 960 732 462 833 445 719 1014 1036
111 1016 979 733 475 865 425 690 954 1024 938 761 463 820 438 746 992 1016
112 998 961 759 474 849 432 722 930 1007 911 769 476 803 453 765 971 998
113 980 934 774 496 841 448 733 907 983 893 760 498 806 473 773 948 980
114 962 912 758 517 861 472 743 890 958 873 741 519 840 496 750 921 962
115 939 895 744 535 898 492 717 860 942 845 719 534 877 516 731 904 939
116 918 872 721 555 934 509 704 835 925 818 699 550 913 533 705 882 918
117 904 845 704 574 975 525 682 818 896 799 675 566 949 544 679 853 904
118 884 825 683 587 1016 532 661 794 872 771 659 573 987 554 656 833 884
119 855 807 669 588 1052 537 643 766 857 742 635 565 1023 553 623 816 855
120 838 778 647 579 1084 530 622 751 828 717 617 559 1048 542 599 788 838
NVLAP LAB CODE 201011-0
Report No.: GZE160226-A
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
14 / 17
121 821 759 630 571 1106 524 605 725 795 691 598 551 1057 528 578 765 821
122 793 738 615 563 1104 516 586 701 772 664 581 543 1044 518 560 746 793
123 771 715 596 555 1091 508 574 681 742 632 560 536 1031 509 542 719 771
124 744 692 583 550 1076 500 556 656 684 602 547 531 1016 501 528 697 744
125 601 669 567 543 1060 495 540 634 537 576 531 529 1000 494 509 673 601
126 458 648 551 538 1043 493 525 610 406 546 510 523 983 491 493 648 458
127 387 625 530 531 1025 488 506 588 331 525 488 518 965 492 481 625 387
128 317 603 507 525 1008 484 481 565 258 503 467 517 947 489 469 600 317
129 281 578 482 521 988 482 459 544 233 476 443 513 927 484 461 575 281
130 344 545 457 517 969 481 436 518 283 446 422 510 907 481 441 542 344
131 374 510 432 507 950 479 409 488 273 413 395 504 887 477 418 504 374
132 366 467 405 501 929 475 383 455 257 372 371 498 866 472 397 462 366
133 358 419 382 495 908 472 356 415 246 337 348 494 844 465 371 412 358
134 346 376 356 485 888 469 329 372 234 300 328 490 823 459 344 369 346
135 335 332 337 485 867 466 311 331 219 268 311 485 803 455 309 331 335
136 322 291 314 482 847 464 293 290 203 236 288 481 784 451 280 292 322
137 307 253 297 479 828 461 276 249 192 193 273 475 764 447 259 256 307
138 285 217 279 475 808 460 264 218 190 161 255 469 744 444 233 215 285
139 264 186 262 470 786 457 248 171 200 116 239 462 723 440 215 179 264
140 253 163 247 462 764 451 232 133 203 71 225 451 703 436 190 158 253
141 238 120 231 452 741 444 217 106 141 32 208 440 679 428 163 115 238
142 220 76 215 441 715 438 204 84 77 16 195 427 654 419 146 73 220
143 153 44 202 430 686 432 192 85 27 47 183 412 629 409 134 47 153
144 80 62 189 420 656 425 184 84 17 76 169 399 604 398 129 60 80
145 42 93 176 411 629 416 176 73 51 117 157 383 581 389 126 90 42
146 83 122 167 401 602 407 171 57 94 141 149 368 556 380 123 114 83
147 117 123 159 388 576 397 170 44 124 127 141 352 531 370 122 114 117
148 112 114 151 374 547 388 170 38 114 114 131 335 505 359 115 101 112
149 97 111 145 358 516 380 170 35 99 98 120 316 477 345 110 95 97
150 82 106 140 343 484 373 171 31 86 89 106 299 449 329 115 94 82
151 67 96 135 329 453 364 172 27 76 76 92 280 421 315 118 88 67
NVLAP LAB CODE 201011-0
Report No.: GZE160226-A
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
15 / 17
152 54 83 133 317 424 351 175 22 59 63 72 263 397 301 121 75 54
153 43 71 126 303 397 338 175 20 50 52 51 244 373 287 118 60 43
154 34 59 115 288 370 325 175 22 40 42 26 223 345 271 108 50 34
155 26 48 102 271 341 311 171 21 29 32 12 203 320 256 93 43 26
156 20 42 80 256 314 294 169 10 22 25 6 184 297 240 75 37 20
157 15 38 59 240 290 276 161 5 20 21 6 160 273 226 53 33 15
158 13 36 40 222 264 258 148 6 16 18 11 126 249 209 31 31 13
159 12 34 24 204 239 236 133 15 7 10 17 88 226 188 15 30 12
160 11 31 17 179 216 213 115 28 4 5 22 48 205 161 9 28 11
161 10 29 22 145 191 188 84 46 5 4 25 20 178 125 12 26 10
162 10 28 32 96 158 156 54 50 9 4 27 17 144 78 16 24 10
163 10 26 40 52 116 111 27 54 14 6 26 24 95 37 26 23 10
164 10 24 43 19 64 62 13 52 18 9 22 42 49 11 29 21 10
165 10 22 36 6 28 28 17 50 17 9 22 56 15 4 28 19 10
166 9 20 28 4 11 11 28 45 16 8 20 51 8 5 22 17 9
167 9 17 18 16 15 15 46 40 15 8 18 45 14 16 15 15 9
168 8 15 8 26 31 32 54 35 15 8 14 34 34 23 7 12 8
169 8 12 3 23 46 45 47 30 13 7 10 28 41 21 3 9 8
170 7 9 3 19 41 41 38 25 11 6 10 17 29 17 3 6 7
171 5 4 3 15 32 32 30 20 10 6 8 13 26 14 3 3 5
172 3 3 3 12 23 23 21 16 8 5 6 11 20 10 3 3 3
173 3 3 5 9 16 16 16 12 7 4 5 8 14 8 4 3 3
174 2 3 5 7 11 11 11 9 5 3 3 7 9 6 4 3 2
175 2 3 5 5 7 7 8 6 4 3 3 5 7 5 4 3 2
176 3 3 4 4 5 5 6 5 3 2 3 4 5 4 3 3 3
177 3 3 3 3 3 3 4 3 2 2 2 3 3 2 3 2 3
178 2 2 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2
179 2 2 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2
180 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
NVLAP LAB CODE 201011-0
Report No.: GZE160226-A
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
16 / 17
NVLAP LAB CODE 201011-0
Report No.: GZE160226-A
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
17 / 17
3. Test Equipment
Equipment ID Equipment Name Last Calibration Date Next Calibration Date
ST-R-336 2 meter Integrating Sphere 2015-07-01 2016-06-30
ST-R-331 Spectral analysis system HAAS-2000 2015-07-01 2016-06-30
D204 Standard Lamp 2015-07-01 2016-06-30
PF2010 Power Meter for Integrating Sphere 2015-07-01 2016-06-30
EE-09 Goniophotometer system 2015-07-01 2016-06-30
D908S Standard Lamp 2015-07-01 2016-06-30
PF210 Power Meter for Goniophotometer 2015-07-01 2016-06-30
ST-R-181A Temperature Tester 2015-07-01 2016-06-30
Uncertainty
Photometric Measurement (Sphere):1.74%
Chromaticity Measurement(Sphere):14.3K
Photometric Measurement(Goniophotometer):1.62%
****** END OF DATASHEET PACKAGE ******