Liverpool John Moores University Former Royal Mail Sorting ... Disclosure...Liverpool John Moores...
Transcript of Liverpool John Moores University Former Royal Mail Sorting ... Disclosure...Liverpool John Moores...
Liverpool John Moores University
Former Royal Mail Sorting Office, Copperas Hill, Liverpool, L2 0QN
WYG Asbestos Refurbishment / Demolition Survey Report
10 Apr 2015
WYG Environment
part of the WYG group ..................................................................................
230 www.wyg.com Page 1 of 386 creative minds safe hands.......................................................................................
Document Control
Document Checking:
Project: Refurbishment & Demolition SurveysClient: Liverpool John Moores UniversityJob Number: J004560File Origin: 17
Prepared by: Jonathan Ford Signed:
Quality Manager
Verified by: Peter Worth Signed:
Principal Consultant
Issue Date Status
1 10 Apr 2015
2 10 Apr 2015 updated photos updated drawings to improve clarity and annotation
3 10 Apr 2015 Update of site plans
4 10 Apr 2015 Update of site plans
5 10 Apr 2015 Addition of duct survey data & amendment to drawings
WYG Environment
part of the WYG group ..................................................................................
www.wyg.com Page 2 of 386 creative minds safe hands.......................................................................................
Contents Page
Table Contents
Appendix Contents
0.0 Executive Summary...........................................................................................................................
1.0 Introduction......................................................................................................................................
2.0 Site Details.......................................................................................................................................
3.0 Survey Methodology..........................................................................................................................
4.0 Survey Conditions.............................................................................................................................
5.0 Asbestos Register.............................................................................................................................
6.0 Recommendations.............................................................................................................................
7.0 Glossary of Terms.............................................................................................................................
8.0 References.......................................................................................................................................
Table 1 Areas of No Access.................................................................................................................
Appendix A – Report Conditions for WYG Asbestos Refurbishment / Demolition Survey
Appendix B – Inspection Reports
Appendix C – Material Risk Assessment Criteria
Appendix D – Site Sketches
Appendix E – Analysis Certificates
Contents Page
Table Contents
Appendix Contents
0.0 Executive Summary........................................................................................................................... 4
1.0 Introduction...................................................................................................................................... 5
2.0 Site Details....................................................................................................................................... 6
3.0 Survey Methodology.......................................................................................................................... 14
4.0 Survey Conditions............................................................................................................................. 16
5.0 Asbestos Register............................................................................................................................. 19
6.0 Recommendations............................................................................................................................. 51
7.0 Glossary of Terms............................................................................................................................. 55
8.0 References....................................................................................................................................... 56
Table 1 Areas of No Access................................................................................................................. 17
Appendix A – Report Conditions for WYG Asbestos Refurbishment / Demolition Survey
Appendix B – Inspection Reports
Appendix C – Material Risk Assessment Criteria
Appendix D – Site Sketches
Appendix E – Analysis Certificates
WYG Environment
part of the WYG group ..................................................................................
www.wyg.com Page 3 of 386 creative minds safe hands.......................................................................................
0.0 Executive Summary
Site Address The site address is Former Royal Mail Sorting Office, Copperas Hill, Liverpool L2 0QN.
General Site Description
The site comprises 1 building. The site is used as Former Royal Mail Sorting Office.
Date and type of survey undertaken
It is understood from the client that the survey was undertaken to provide a higher level of information to refurbishment/demolition contractors/assist with the compliance of the Control of Asbestos Regulations (CAR) 2012. A WYG Asbestos Refurbishment / Demolition Survey was undertaken in accordance with HSG 264 Asbestos; The Survey Guide. The WYG Asbestos Refurbishment / Demolition Survey was conducted between 14th January and 4th February 2014 by Andrew Noone, Jonathan Ford and Tom Sendall of WYG Environment Planning Transport Ltd. A further visit was conducted to include the vehicle exhaust duct system on 23rd February 2015 by Peter Worth & Jonathan Ford of WYG. Sample analysis techniques were UKAS accredited in accordance with HSG 248 – Asbestos: The Analysts Guide for Sampling, Analysis and Clearance Procedures, 2005.
Summary of Asbestos Containing Materials Identified
A total of 110 no. samples were analysed following the survey. Of these, 49 no. samples were confirmed as asbestos. This led to the identification of 193 no. items. These include the following material types:
● Asbestos Cement ● Asbestos Insulating Board ● Asbestos Textiles/Paper ● Dust/Debris ● Reinforced Composite ● Well Bound Material
Areas of No Access Every effort was made to access all areas of the site. Inaccessible areas and limitations of a WYG Asbestos Refurbishment / Demolition Survey are detailed in Sections 4.2 and 4.3 of this report. Inaccessible areas should be presumed to contain asbestos containing materials (ACM’s) until such time as an inspection can be made that proves otherwise, as required by the Control of Asbestos Regulations (CAR) 2012.
This sheet is intended to provide a summary only of the asbestos survey findings. It does not provide a definitive engineering analysis for the purposes of costing or construction and is subject to the limitations of this WYG Asbestos Refurbishment / Demolition Survey.
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 4 of 386
.......................................................................................
1.0 Introduction
1.1 General
WYG Environment Planning Transport Ltd (WYG) was commissioned by Liverpool John Moores University to undertake a WYG Asbestos Refurbishment / Demolition survey at the Former Royal Mail Sorting Office, Copperas Hill, Liverpool L2 0QN.
Andrew Noone, Jonathan Ford and Tom Sendall undertook the survey between 14th January and 4th February 2014. A further visit was conducted to include the vehicle exhaust duct system on 23rd February 2015 by Peter Worth & Jonathan Ford of WYG.
1.2 Objectives
A WYG Asbestos Refurbishment / Demolition survey was undertaken at the site in order to meet the following objectives:
● To identify the presence, location and condition of reasonably accessible asbestos containing materials (ACM’s). ● To produce a report to identify areas of confirmed and suspected asbestos and to provide an indication as to
their location, condition and extent.
1.3 Report Conditions
This report has been prepared in accordance with the accepted service details, terms and conditions of our accepted proposal letter Q004569. The report is further subject to the conditions detailed in Appendix A.
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 5 of 386
.......................................................................................
2.0 Site Details
2.1 Location
The site address is Former Royal Mail Sorting Office, Copperas Hill, Liverpool.
2.2 Buildings
The site comprises 1 building. The site is used as Former Royal Mail Sorting Office.
Specific areas included within the survey scope are as follows:
● Copperas Hill/External/1 Roof room 3 tank room ● Copperas Hill/External/2 Roof room 4 lift motor room ● Copperas Hill/External/3 Roof room 6 lift motor room ● Copperas Hill/External/4 Roof room 5 tank room ● Copperas Hill/External/5 Roof room 7a lift motor room ● Copperas Hill/External/6 Roof room 7b tank room ● Copperas Hill/External/7 Riser tower lift motor room ● Copperas Hill/External/8 Riser tower lift motor room lower level ● Copperas Hill/External/9 Roof lift motor room 2 ● Copperas Hill/External/10 Roof lift motor room 2 lobby ● Copperas Hill/External/11 Roof lift motor room 2 Lobby Riser Tower ● Copperas Hill/External/12 Roof lift motor room 2 upper level tank room ● Copperas Hill/External/13 Roof ventilation plant room 2 ● Copperas Hill/External/14 Roof ventilation plant room 1 ● Copperas Hill/External/15 Roof ● Copperas Hill/External/16 Entrance to Service Centre ● Copperas Hill/External/17 Plant Room and Substation External Canopy ● Copperas Hill/External/18 West Tower Loading bay (Level 1) ● Copperas Hill/External/ Wash Cabin ● Copperas Hill/External/ Security Box ● Copperas Hill/External/ Main Entrance ● Copperas Hill/External/External Window Infills (Behind Brown Panels) ● Copperas Hill/5th Floor/1 Lift lobby ● Copperas Hill/5th Floor/2 Lift lobby spiral staircase ● Copperas Hill/5th Floor/3 Lift lobby riser ● Copperas Hill/5th Floor/4 Room 31 Cleaners ● Copperas Hill/5th Floor/5 Room 30 Lockers ● Copperas Hill/5th Floor/6 Riser tower upper and lower level ● Copperas Hill/5th Floor/7 Corridor ● Copperas Hill/5th Floor/8 Room 34 ● Copperas Hill/5th Floor/9 Room 34a ● Copperas Hill/5th Floor/10 Room 33 Toilets ● Copperas Hill/5th Floor/11 Room 33a Records Room ● Copperas Hill/5th Floor/12 Room 38 Training ● Copperas Hill/5th Floor/13 Room 39
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 6 of 386
.......................................................................................
● Copperas Hill/5th Floor/14 Rooms 40 and 41 ● Copperas Hill/5th Floor/15 Room 42 ● Copperas Hill/5th Floor/16 Room 43 ● Copperas Hill/5th Floor/17 Room 44 ● Copperas Hill/5th Floor/18 Room 48 ● Copperas Hill/5th Floor/19 T.P.M. Library ● Copperas Hill/5th Floor/20 Waiting room ● Copperas Hill/5th Floor/21 Room 47 A.C.M. Store ● Copperas Hill/5th Floor/22 Room 46 Office ● Copperas Hill/5th Floor/23 Room 45 Resource Section ● Copperas Hill/5th Floor/24 Revenue Management ● Copperas Hill/5th Floor/25 Room 35 Classroom 3 ● Copperas Hill/5th Floor/26 Male toilet riser ● Copperas Hill/5th Floor/27 Male toilets ● Copperas Hill/5th Floor/28 Room 10 Female Lockers ● Copperas Hill/5th Floor/29 Room 32 Female Toilets ● Copperas Hill/5th Floor/30 Room 16 Lockers ● Copperas Hill/5th Floor/31 Room 13 Lockers ● Copperas Hill/5th Floor/32 Room 17 Societies ● Copperas Hill/5th Floor/33 Room 14 ● Copperas Hill/5th Floor/34 Room 86 ● Copperas Hill/5th Floor/35 Room 87 ● Copperas Hill/5th Floor/36 Room 88 ● Copperas Hill/5th Floor/37 Room 89 ● Copperas Hill/5th Floor/38 Room 90 ● Copperas Hill/5th Floor/39 Room 98 ● Copperas Hill/5th Floor/40 Room 93 ● Copperas Hill/5th Floor/41 Room 94 ● Copperas Hill/5th Floor/42 Room 59 ● Copperas Hill/5th Floor/43 Rooms 58 and 57 ● Copperas Hill/5th Floor/44 Rooms 56 ● Copperas Hill/5th Floor/45 Rooms 55 ● Copperas Hill/5th Floor/46 Room 54 ● Copperas Hill/5th Floor/47 Room 53 ● Copperas Hill/5th Floor/48 Rooms 46b, 46c, 46d, 46e
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 7 of 386
.......................................................................................
● Copperas Hill/5th Floor/49 Rooms 46 and 46a ● Copperas Hill/5th Floor/50 Room 47 and Store ● Copperas Hill/5th Floor/51 Rooms 48, 49, 51, 52 ● Copperas Hill/5th Floor/52 Room 71 Store ● Copperas Hill/5th Floor/53 Room 73 Secure area ● Copperas Hill/5th Floor/54 Medical Suite Rooms 100 - 108 ● Copperas Hill/5th Floor/55 Rooms 60 - 62 ● Copperas Hill/5th Floor/56 Room 63 ● Copperas Hill/5th Floor/57 Rooms 65 ● Copperas Hill/5th Floor/58 Room 64 ● Copperas Hill/5th Floor/59 Room 66 ● Copperas Hill/5th Floor/60 Room 85 Syphon ● Copperas Hill/5th Floor/61 Room 67 ● Copperas Hill/5th Floor/62 Room 68 ● Copperas Hill/5th Floor/63 Room 95 Kitchen ● Copperas Hill/5th Floor/64 Room 97 ● Copperas Hill/5th Floor/65 Room 84 ● Copperas Hill/5th Floor/66 Room 99 ● Copperas Hill/5th Floor/67 Room 29 ● Copperas Hill/5th Floor/68 Room 28 ● Copperas Hill/5th Floor/69 Room 27 ● Copperas Hill/5th Floor/70 Room 24 ● Copperas Hill/5th Floor/71 Room 25 ● Copperas Hill/5th Floor/72 Room 26 ● Copperas Hill/5th Floor/73 Room 23 ● Copperas Hill/5th Floor/74 Corridor outside Room 23 ● Copperas Hill/5th Floor/75 Shop ● Copperas Hill/5th Floor/76 Shop Store ● Copperas Hill/5th Floor/77 Room15 Games room ● Copperas Hill/5th Floor/78 Room 22 Female WC ● Copperas Hill/5th Floor/79 Room 4 Dining room/servery ● Copperas Hill/5th Floor/80 Room 69 Smoking Lounge ● Copperas Hill/5th Floor/81 Room 70 Non Smoking Lounge ● Copperas Hill/5th Floor/82 Room 18 Kitchen ● Copperas Hill/5th Floor/83 Room 19 Kitchen Manager
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 8 of 386
.......................................................................................
● Copperas Hill/5th Floor/84 Room 20 Store ● Copperas Hill/5th Floor/85 Kitchen freezers ● Copperas Hill/5th Floor/86 Room 36 Quadrant Office ● Copperas Hill/5th Floor/87 Room 75 ● Copperas Hill/5th Floor/88 Room 76 ● Copperas Hill/5th Floor/89 Room 21 ● Copperas Hill/5th Floor/90 Room 5 ● Copperas Hill/5th Floor/91 Room 6 ● Copperas Hill/5th Floor/92 Room 7 ● Copperas Hill/5th Floor/93 Room 8 ● Copperas Hill/5th Floor/94 Room 9 ● Copperas Hill/4th Floor Mezzanine Floor/1 Main lobby ● Copperas Hill/4th Floor Mezzanine Floor/2 Main riser ● Copperas Hill/4th Floor Mezzanine Floor/3 Old server room ● Copperas Hill/4th Floor Mezzanine Floor/4 Kitchen Lobby ● Copperas Hill/4th Floor Mezzanine Floor/5 Kitchen ● Copperas Hill/4th Floor Mezzanine Floor/6 Toilets ● Copperas Hill/4th Floor Mezzanine Floor/7 Mezzanine offices North ● Copperas Hill/4th Floor Mezzanine Floor/8 UPS Room ● Copperas Hill/4th Floor Mezzanine Floor/4m West Tower 4mw1 - 4mw3 ● Copperas Hill/4th Floor Mezzanine Floor/4m South West Tower 4msw1-4msw3 ● Copperas Hill/4th Floor Mezzanine Floor/4m South East Tower 4mse1- 4mse 3a,b & c ● Copperas Hill/4th Floor/1 Room 25 Lift Lobby ● Copperas Hill/4th Floor/2 Rooms 23 and 24 Toilets ● Copperas Hill/4th Floor/3 Room 20 Riser Tower ● Copperas Hill/4th Floor/4 Lift lobby riser ● Copperas Hill/4th Floor/5 Room 19 OCR Training ● Copperas Hill/4th Floor/6 Rooms 15, 17, 18 ● Copperas Hill/4th Floor/7 Room 14 ● Copperas Hill/4th Floor/8 Above Room 19 ● Copperas Hill/4th Floor/9 Security viewing gallery ● Copperas Hill/4th Floor/10 Rooms 26-27 ● Copperas Hill/4th Floor/11 Rooms 29 ● Copperas Hill/4th Floor/12 Rooms 28 ● Copperas Hill/4th Floor/13 Rooms 30
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 9 of 386
.......................................................................................
● Copperas Hill/4th Floor/14 Rooms 31-35 ● Copperas Hill/4th Floor/15 Room 37 Safe ● Copperas Hill/4th Floor/16 Rooms 26-30 ● Copperas Hill/4th Floor/17 Room 23-24 Toilet Riser ● Copperas Hill/4th Floor/18 Room 36 Chain enclosure ● Copperas Hill/4th Floor/19 Rooms 38-39 ● Copperas Hill/4th Floor/20 Room 40 Female wc ● Copperas Hill/4th Floor/21 Room 41 Lift Lobby ● Copperas Hill/4th Floor/22 Riser adjacent room 41 ● Copperas Hill/4th Floor/23 Riser adjacent room 55 ● Copperas Hill/4th Floor/24 Room 55 Lift Lobby ● Copperas Hill/4th Floor/25 Room 54 Male WC ● Copperas Hill/4th Floor/26 South West Lift Lobby ● Copperas Hill/4th Floor/27 Room 48 Male WC ● Copperas Hill/4th Floor/28 Room 47 Male wc ● Copperas Hill/4th Floor/29 Room 46-42 ● Copperas Hill/4th Floor/30 West Stair Lobby ● Copperas Hill/4th Floor/31 Room 2, cleaners ● Copperas Hill/4th Floor/32 Room 1 Female wc ● Copperas Hill/4th Floor/33 Room 56, main floor area ● Copperas Hill/4th Floor/34 Lift Moor Room for LSG001 ● Copperas Hill/3rd Floor Mezzanine Floor/1 North Lift Lobby ● Copperas Hill/3rd Floor Mezzanine Floor/2 North Engineers Riser ● Copperas Hill/3rd Floor Mezzanine Floor/3 North Locker Room ● Copperas Hill/3rd Floor Mezzanine Floor/4 North Lockers Riser ● Copperas Hill/3rd Floor Mezzanine Floor/5 Conveyor gallery ● Copperas Hill/3rd Floor Mezzanine Floor/6 East Stamp Store ● Copperas Hill/3rd Floor Mezzanine Floor/7 East Male WC ● Copperas Hill/3rd Floor Mezzanine Floor/8 South East Male WC ● Copperas Hill/3rd Floor Mezzanine Floor/9 South East Female WC ● Copperas Hill/3rd Floor Mezzanine Floor/10 South West Female WC ● Copperas Hill/3rd Floor Mezzanine Floor/11 South West Office ● Copperas Hill/3rd Floor Mezzanine Floor/12 South West Lobby ● Copperas Hill/3rd Floor Mezzanine Floor/16 Throughout level 3 Mezz ● Copperas Hill/3rd Floor Mezzanine Floor/34 Room 18 Mezz plant room
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 10 of 386
.......................................................................................
● Copperas Hill/3rd Floor Mezzanine Floor/17 Room 17 above G6 lift ● Copperas Hill/3rd Floor/1 Room 34 Entrance lobby/Reception ● Copperas Hill/3rd Floor/2 Room 37 ● Copperas Hill/3rd Floor/3 Room 38 Loading Bays ● Copperas Hill/3rd Floor/4 Security viewing galleries throughout. ● Copperas Hill/3rd Floor/5 Room 35 Male WC ● Copperas Hill/3rd Floor/6 Room 36 Riser ● Copperas Hill/3rd Floor/13 Room 33 ● Copperas Hill/3rd Floor/14 Lift motor rooms in main loading bay ● Copperas Hill/3rd Floor/7 Room 33 ● Copperas Hill/3rd Floor/8 Room 39 Revenue Management ● Copperas Hill/3rd Floor/9 Room 40 ● Copperas Hill/3rd Floor/10 Room 41 ● Copperas Hill/3rd Floor/11 Room 61 (above room 41) ● Copperas Hill/3rd Floor/12 Room 42 Male WC ● Copperas Hill/3rd Floor/13 Room 43 Lobby ● Copperas Hill/3rd Floor/14 Room 52 ● Copperas Hill/3rd Floor/15 Room 50 ● Copperas Hill/3rd Floor/16 Room 56 ● Copperas Hill/3rd Floor/17 Room 54 ● Copperas Hill/3rd Floor/18 Room 55 ● Copperas Hill/3rd Floor/19 Welfare enclosures 15, 16, 17, 18 ● Copperas Hill/3rd Floor/20 Room 21 Safe ● Copperas Hill/3rd Floor/21 Room 22 ● Copperas Hill/3rd Floor/22 Room 23 ● Copperas Hill/3rd Floor/23 Room 20 ● Copperas Hill/3rd Floor/24 Rooms 12 and 9 ● Copperas Hill/3rd Floor/25 Rooms 6, 45, 46 Priority services and offices ● Copperas Hill/3rd Floor/26 Room 10 Corridor and Lobby ● Copperas Hill/3rd Floor/27 Rooms 25, 26, 27 and 29 ● Copperas Hill/3rd Floor/28 Room 28 Strong room ● Copperas Hill/3rd Floor/29 Room 31 ● Copperas Hill/3rd Floor/30 Room 30 Male WC ● Copperas Hill/3rd Floor/31 Rooms 57, 58, 59, 60 ● Copperas Hill/3rd Floor/32 Rooms 1, 3, 4, 5
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 11 of 386
.......................................................................................
● Copperas Hill/3rd Floor/33 Rooms 2 and 7 Toilets ● Copperas Hill/3rd Floor/15 Room 24 Sorting area ● Copperas Hill/3rd Floor/ Throughout Level 3 ● Copperas Hill/3rd Floor/Riser Tower Conveyor to Tunnel ● Copperas Hill/2nd Floor/1 Room 29 Boiler Room ● Copperas Hill/2nd Floor/2 Room 28 Tank Room ● Copperas Hill/2nd Floor/3 Lift lobby x2 S/W Tower ● Copperas Hill/2nd Floor/4 Male WC S/W Tower ● Copperas Hill/2nd Floor/5 Store S/W Tower ● Copperas Hill/2nd Floor/6 Main Corridor ● Copperas Hill/2nd Floor/7 Rooms 19-23 ● Copperas Hill/2nd Floor/8 Rooms 17 and 18 ● Copperas Hill/2nd Floor/9 Rooms 2a,b and c (West) ● Copperas Hill/2nd Floor/10 Room 2 Cleaners (West) ● Copperas Hill/2nd Floor/11 Lift lobby West Tower ● Copperas Hill/2nd Floor/12 Room 1 Union Room ● Copperas Hill/2nd Floor/13 Room 2 Female WC W Tower ● Copperas Hill/2nd Floor/14 Room 5 Addressograph Room ● Copperas Hill/2nd Floor/15 Room 6 Addressograph Store ● Copperas Hill/2nd Floor/16 Rooms 7-9, 14-15 Classrooms 1 and 2 and adjacent ● Copperas Hill/2nd Floor/17 Rooms 10 - 13 Callers Office and associated areas ● Copperas Hill/2nd Floor/18 Room 35 - 36 ● Copperas Hill/2nd Floor/19 Fume Extract and Plenum Chamber (accessed via 37) ● Copperas Hill/2nd Floor/20 Room 29a Engineers Workshop and 30 Electric ● Copperas Hill/2nd Floor/21 Room 38 and 39 ● Copperas Hill/2nd Floor/22 Room 24 - 27 ● Copperas Hill/2nd Floor/ Throughout Level 2 ● Copperas Hill/2nd Floor/Riser Tower Conveyor to Tunnel ● Copperas Hill/1st Floor/1 Room 12 Lift lobby ● Copperas Hill/1st Floor/2 Room 11 and 13 Sensitive Waste ● Copperas Hill/1st Floor/3 Room 3 and 10 ● Copperas Hill/1st Floor/4 Room 5 - 9 ● Copperas Hill/1st Floor/5 Room 4 ● Copperas Hill/1st Floor/6 West Tower Corridor ● Copperas Hill/1st Floor/7 Room 1 and 2
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 12 of 386
.......................................................................................
● Copperas Hill/1st Floor/ Throughout Level 1 ● Copperas Hill/Lift Shaft/1 G4 (LPG 009) ● Copperas Hill/Lift Shaft/2 G2 (LPG 007) ● Copperas Hill/Lift Shaft/3 G1 (LPG 006) ● Copperas Hill/Lift Shaft/4 P1-3 Passenger Lift ● Copperas Hill/2nd Floor Mezzanine Floor/2M-001 Vehicle Exhaust Duct - South (Lower) ● Copperas Hill/2nd Floor Mezzanine Floor/2M-002 Vehicle Exhaust Duct - North West (Upper) ● Copperas Hill/2nd Floor Mezzanine Floor/2M-003 Vehicle Exhaust Duct - North (Upper) ● Copperas Hill/2nd Floor Mezzanine Floor/2M-004 Vehicle Exhaust Duct - East (Lower)
Specific areas excluded from the survey scope are as follows:
● Riser tower below level 2 ● Electrical substations
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 13 of 386
.......................................................................................
3.0 Survey Methodology
A WYG Asbestos Refurbishment / Demolition survey, using the methodology set out in HSG 264 was undertaken. Each accessible area was inspected to locate materials presumed or strongly presumed to contain asbestos, all of which must be removed prior to demolition and/or major refurbishment.
Photographs of each sample location were taken, however where similar materials were identified these are referenced to similar homogeneous materials.
Each sample is assessed using a material assessment algorithm, which assigns a score of risk to each individual ACM based the following criteria:
● Product Type; ● Extent of Damage or Deterioration; ● Surface Treatment; and ● Asbestos Type
Each criterion has various scores and when all the scores for each are added together a value of risk is generated for the material. This is only a requirement of HSG 264 for Management Surveys; however, the algorithm values have been applied during this survey as we understand that contractors may visit the site prior to demolition.
All samples were analysed by a UKAS accredited laboratory using Polarised Light Microscopy and Dispersion Staining techniques in accordance with HSG 248.
Priority must be determined by carrying out a risk assessment (ie a priority assessment) which will take into account factors such as:
● the location of the material; ● the extent of the material; ● the use to which the location is put; ● the occupancy of the area; ● the activities carried on in the area; and ● the likelihood/frequency with which maintenance activities are likely to take place.
The priority assessment can only be carried out with the detailed knowledge of all these factors. The surveyor can help in this process, by obtaining information which will contribute to the priority assessment, particularly in small or simple premises where information on occupancy and use is straightforward. However, such help must be undertaken with caution. It is the duty holder, under CAR 2012, who is required to make the risk assessment using their detailed knowledge of the activities carried out in the premises. Priority assessments provided are outside the scope of our UKAS accreditation.
The combined material and priority assessment results should be used to establish the priority for those ACMs needing remedial action and the type of action that will be taken. There are various remedial options available: in many cases the ACMs can be protected or enclosed, sealed or encapsulated, or repaired. These options should be considered first. Where such actions are not practical, ACMs should be removed. Further information on risk assessments and management of asbestos is available in A comprehensive guide to managing asbestos in premises.
Sampling of suspect materials is completed in accordance with HSG264 and our accreditation by UKAS to ISO 17020. By its nature, sampling building materials may include a limited damage and WYG accept no responsibility for making
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 14 of 386
.......................................................................................
good such areas, unless agreed in writing advance of the survey.
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 15 of 386
.......................................................................................
4.0 Survey Conditions
4.1 Access Constraints
All areas within the scope of works were accessed (unless stated in Section 4.3) for the presence of ACM’s and where ACM’s were presumed and/or strongly presumed samples were taken. These presumptions are based upon surveyors experience associated with identification of a particular material.
4.2 Survey Limitations
Whilst the surveyors made every effort, WYG cannot guarantee that all asbestos containing materials have been identified, or that survey results are definitive. Specific areas of the site where suitable access was not available are recorded in Section 4.3 of this document.
Features that generally fall outside the scope of a WYG Asbestos Refurbishment / Demolition survey include:
● Within solid floor voids (e.g. Concrete Slab), where no inspection hatch is present. ● Areas behind or above suspected asbestos containing materials¹ ● Within solid concrete floors where asbestos shuttering may have been used ● Within confined spaces etc. where reasonable access is unavailable² ● Within live plant or electrical apparatus unless specifically mentioned within the report ● Beneath lagging or cladding of live pipes where a burn hazard may be present ● Concealed pipe runs, where reasonable access in unavailable ● Areas that are considered to present a significant Health & Safety risk. ● Within live plant or electrical apparatus ● Areas where access may involve damaging the fabric of the building
¹ Areas behind or above suspected asbestos containing materials are required to be inspected by HSG264. Where such areas could not be identified prior to the commission of the survey, a provisional sum should have been allowed for by the client to enable the surveyor to return to site with a licensed asbestos contractor in order to gain access. Such access may also necessitate 14–day (ASB5) notification to the HSE and may require concurrent air monitoring to be carried out. Should this type of access have been required, we liaises and sought agreement from the project team before commencing beyond the agreed project scope.
² Where access is restricted due to confined space or other health & safety concerns, these areas will be detailed in the report and recommendations given for the most appropriate means of investigation, and if necessary, any additional costs which would be entailed. A strategy of using representative samples of suspected asbestos materials has been used to minimise the number of samples taken to a practical level and keep to a minimum the disturbance of potential asbestos containing materials at the site. Because of this strategy the results of the survey should be interpreted such that all visually similar materials in the same area must be assumed to be composed of the same material until proven otherwise.
In accordance with The Control of Asbestos Regulations 2012, it must be assumed that materials visually assessed as asbestos containing materials contain amphibole asbestos fibres (i.e. Amosite and Crocidolite), unless sampled to prove otherwise.
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 16 of 386
.......................................................................................
4.3 Areas of No Access
Table 1 Areas of No Access
4.4 Survey Specific Notes
There is always a possibility that asbestos materials other than those highlighted by this report are present in those areas not accessed fully at the time of the survey.
Inaccessible areas should be presumed to contain amphibole asbestos and appropriate management planning should be implemented in order to control access and maintenance activities to these areas until such a time as they can be accessed and the presence or absence of asbestos containing materials can be confirmed.
A strategy of using representative samples of suspected asbestos materials has been used to minimise the number of samples taken to a practical level and keep to a minimum the disturbance of potential asbestos containing materials. Because of this strategy the results of the survey should be interpreted such that all visually similar materials in the same area must be assumed to be composed of the same material until proven otherwise.
Room Number Area of No Access Reason
Throughout Building Locked safes No keys
Throughout Building Toilets & Risers- above timber shuttering to high
level ceiling
Limited access - Concrete identified above, internals of shuttering not viewed due to height
of boxing
Level 2 Room 28 Tank Room Sump void Unable to survey void due to flooding
Level 2 Room 38 Fume Extract
Exhaust duct Fixed Metal Louvres prevent access
Level 3 Room 35 & 42 WC Floor duct Manhole fixed
Level 3 Room 39 Revenue Management
Beneath heavy duty floor scale recessed into concrete
floor
Could not be lifted safely
Level 5 Room 30 Lockers Behind plasterboard high level window infills
Asbestos contamination in ceiling void
Level 4 MezzMain Lobby Wall safe No key
G1 Lift (lpg001) Metal safety grid in shaft No safe access
G1 Lift (lpg001) Shaft Below level 2 No access doors locked at tunnel
G2 Lift (lpg007) Shaft Limited access only viewed from level 5 and pit area
Lift broken
G1 & G2 Lift Shaft Behind metal door aprons No safe access
LSG 001 Lift Wall void at ceiling level of shaft
High level access within lift shaft required
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 17 of 386
.......................................................................................
In accordance with The Control of Asbestos Regulations 2012, it must be assumed that materials visually assessed as asbestos containing materials contain amphibole asbestos fibres (i.e. Amosite and Crocidolite), unless strongly presumed otherwise or sampled to prove otherwise.
Asbestos products and non–asbestos products in some areas of the building are located in close proximity to each other. Care must be taken when removing the asbestos in order that contamination of the non–asbestos materials is not caused, as this will increase disposal costs.
Material assessments have been undertaken on the various items inspected. These assessments are carried out according to the material assessment algorithm appended to this report, which is based on the assessment criteria in HSG 264.
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 18 of 386
.......................................................................................
5.0 Asbestos Register
Inspection Number Area Feature Material Type –
(Friability)Asbestos
FibreMaterial
Assessment ScorePriority
Assessment ScoreTotal Assessment
ScoreSample Number Recommendations
5Copperas Hill,
External, Roof room 3 tank room (1)
Presumed asbestos in live electrics
Asbestos Textiles/Paper
(Medium)
(1) Chrysotile 4 N/A N/A - Inspect Prior to
Disturbance
7Copperas Hill,
External, Roof room 4 lift motor room (2)
Presumed asbestos in live electrics
Asbestos Textiles/Paper
(Medium)
(1) Chrysotile 4 N/A N/A - Inspect Prior to
Disturbance
8Copperas Hill,
External, Roof room 6 lift motor room (3)
Presumed asbestos in live electrics
Asbestos Textiles/Paper
(Medium)
(1) Chrysotile 4 N/A N/A - Inspect Prior to
Disturbance
12Copperas Hill,
External, Roof room 5 tank room (4)
Presumed asbestos in live electrics
Asbestos Textiles/Paper
(Medium)
(1) Chrysotile 4 N/A N/A - Inspect Prior to
Disturbance
13Copperas Hill,
External, Roof room 5 tank room (4)
Cement pipe and jointing Asbestos Cement (Low) (1)
Chrysotile 3 N/A N/A AR000246 Remove if likely to be disturbed
14Copperas Hill,
External, Roof room 7a lift motor room (5)
Presumed asbestos in live electrics
Asbestos Textiles/Paper
(Medium)
(1) Chrysotile 4 N/A N/A - Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 19 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability) Asbestos FibreMaterial
Assessment Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
15Copperas Hill,
External, Roof room 7a lift motor room (5)
Insulating board lining to door
Asbestos Insulating Board (Medium) (1) Chrysotile 4 N/A N/A AR000247 Remove if likely to be
disturbed
17Copperas Hill,
External, Roof room 7b tank room
Insulating board lining to door (as sample
AR000247)
Asbestos Insulating Board (Medium) (1) Chrysotile 4 N/A N/A AR000247 Remove if likely to be
disturbed
19Copperas Hill,
External, Riser tower lift motor room (7)
Presumed asbestos in live electrics
Asbestos Textiles/Paper
(Medium)(1) Chrysotile 4 N/A N/A - Inspect Prior to
Disturbance
20Copperas Hill,
External, Riser tower lift motor room (7)
Asbestos brake shoes in lift motor
Asbestos Cement (Low)
(3) Crocidolite (or unknown) 6 N/A N/A - Inspect Prior to
Disturbance
21Copperas Hill,
External, Riser tower lift motor room (7)
Durasteel trap doors Asbestos Insulating Board (Medium) (1) Chrysotile 5 N/A N/A AR000249 Remove if likely to be
disturbed
22
Copperas Hill, External, Riser tower lift motor room lower
level
Durasteel trap doors to ceiling (as sample
AR000249)
Asbestos Insulating Board (Medium) (1) Chrysotile 5 N/A N/A AR000249 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 20 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability) Asbestos FibreMaterial
Assessment Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
24Copperas Hill,
External, Roof lift motor room 2 (9)
Floor tiles Reinforced Composite (Low) (1) Chrysotile 2 N/A N/A AR000252 Remove if likely to be
disturbed
25Copperas Hill,
External, Roof lift motor room 2 (9)
Brake shoes in lift motors Asbestos Cement (Low)
(3) Crocidolite (or unknown) 5 N/A N/A - Remove if likely to be
disturbed
27Copperas Hill,
External, Roof lift motor room 2 (9)
Presumed asbestos in live electrics
Asbestos Textiles/Paper
(Medium)(1) Chrysotile 4 N/A N/A - Inspect Prior to
Disturbance
29Copperas Hill,
External, Roof lift motor room 2 lobby
Insulating board lining to doors (as sample
AR000264)
Asbestos Insulating Board (Medium) (1) Chrysotile 5 N/A N/A AR000264 Remove if likely to be
disturbed
30
Copperas Hill, External, Roof lift motor
room 2 Lobby Riser Tower (11)
Presumed asbestos in live electrics
Asbestos Textiles/Paper
(Medium)(1) Chrysotile 4 N/A N/A - Inspect Prior to
Disturbance
31
Copperas Hill, External, Roof lift motor
room 2 Lobby Riser Tower (11)
Insulating board lining to door
Asbestos Insulating Board (Medium) (1) Chrysotile 5 N/A N/A AR000264 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 21 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability)Asbestos
FibreMaterial
Assessment Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
32Copperas Hill,
External, Roof lift motor room 2 upper level tank room (12)
Presumed asbestos in live electrics
Asbestos Textiles/Paper
(Medium)
(1) Chrysotile 4 N/A N/A - Inspect Prior to
Disturbance
34Copperas Hill,
External, Roof ventilation plant room 2 (13)
Mastic to ventilation duct jointing
Reinforced Composite (Low)
(1) Chrysotile 2 N/A N/A AR000254 Remove if likely to be
disturbed
35Copperas Hill,
External, Roof ventilation plant room 2 (13)
Bitumen above strammit ceiling
Well Bound Material (Low)
(1) Chrysotile 2 N/A N/A AR000255 Remove if likely to be
disturbed
36Copperas Hill,
External, Roof ventilation plant room 2 (13)
Loose gaskets Asbestos Textiles/Paper (Low)
(1) Chrysotile 3 N/A N/A AR000256 Remove if likely to be
disturbed
37Copperas Hill,
External, Roof ventilation plant room 2 (13)
Presumed asbestos in live electrics
Asbestos Textiles/Paper
(Medium)
(1) Chrysotile 4 N/A N/A - Inspect Prior to
Disturbance
38Copperas Hill,
External, Roof ventilation plant room 2 (13)
Insulating board lining to walls
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 22 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability) Asbestos FibreMaterial
Assessment Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
39
Copperas Hill, External, Roof
ventilation plant room 1
Mastic to ventilation duct jointing (as sample
AR000254)
Reinforced Composite (Low) (1) Chrysotile 2 N/A N/A AR000254 Remove if likely to be
disturbed
40
Copperas Hill, External, Roof
ventilation plant room 1
Bitumen above strammit ceiling (as sample
AR000255)
Well Bound Material (Low) (1) Chrysotile 2 N/A N/A AR000255 Remove if likely to be
disturbed
41
Copperas Hill, External, Roof
ventilation plant room 1 (14)
Gaskets to pipework Asbestos Textiles/Paper (Low) (1) Chrysotile 3 N/A N/A AR000258 Remove if likely to be
disturbed
42
Copperas Hill, External, Roof
ventilation plant room 1 (14)
Presumed asbestos in live electrics
Asbestos Textiles/Paper
(Medium)(1) Chrysotile 4 N/A N/A - Inspect Prior to
Disturbance
43
Copperas Hill, External, Roof
ventilation plant room 1
Insulating board lining to walls (as sample
AR000257)
Asbestos Insulating Board (Medium) (2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
44
Copperas Hill, External, Roof
ventilation plant room 1 (14)
Insulating board debris to floor
Asbestos Insulating Board (Medium)
(2) Chrysotile + Amosite 9 N/A N/A AR000259 Restrict access and
remove
Refurbishment & Demolition Surveys / J004560 Page 23 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability)Asbestos
Fibre
Material Assessment
Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
49 Copperas Hill, 5th Floor, Lift lobby
Insulating board behind external metal panels (as sample
AR000257)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
51Copperas Hill,
5th Floor, Lift lobby spiral staircase (2)
Insulating board lining to door Asbestos Insulating Board (Medium)
(1) Chrysotile 6 N/A N/A AR000265 Remove if likely to be
disturbed
52Copperas Hill,
5th Floor, Lift lobby riser
Insulating board lining to door (as sample AR000265)
Asbestos Insulating Board (Medium)
(1) Chrysotile 6 N/A N/A AR000265 Remove if likely to be
disturbed
53Copperas Hill,
5th Floor, Lift lobby riser (3)
Mastic to wall joints Well Bound Material (Low)
(1) Chrysotile 2 N/A N/A AR000266 Remove if likely to be
disturbed
54Copperas Hill,
5th Floor, Room 30 Lockers (5)
Insulating board and associated debris in ceiling void
Asbestos Insulating Board (Medium)
(2) Amosite 8 N/A N/A AR000267 Restrict access and
remove
58Copperas Hill,
5th Floor, Corridor (7)
Mastic to ventilation duct joints Well Bound Material (Low)
(1) Chrysotile 2 N/A N/A AR000270 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 24 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability)Asbestos
Fibre
Material Assessment
Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
59Copperas Hill,
5th Floor, Corridor (7)
Presumed gaskets to pipe work in ceiling void
Well-bound Material (Low)
(1) Chrysotile 2 N/A N/A - Remove if likely to be
disturbed
60Copperas Hill,
5th Floor, Corridor (7)
Rope gaskets to pipe hangers in ceiling void
Asbestos Textiles/Paper
(Medium)
(1) Chrysotile 4 N/A N/A AR000271 Remove if likely to be
disturbed
61Copperas Hill,
5th Floor, Room 34a
Insulating board panels behind external metal infills. (as sample
AR000257)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
62Copperas Hill,
5th Floor, Room 38 Training
Insulating board behind external metal panels (as sample AR000257)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
63Copperas Hill,
5th Floor, Room 39
Insulating board behind external metal panels (as sample AR000257)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
64
Copperas Hill, 5th Floor,
Rooms 40 and 41
Insulating board behind external metal panels (as sample AR000257)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 25 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability)Asbestos
Fibre
Material Assessment
Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
65 Copperas Hill, 5th Floor, Room 42
Insulating board behind external metal panels (as sample
AR000257)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
66 Copperas Hill, 5th Floor, Room 48
Insulating board behind external metal panels (as sample
AR000257)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
67Copperas Hill,
5th Floor, Room 46 Office
Insulating board behind external metal panels (as sample
AR000257)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
68Copperas Hill,
5th Floor, Room 45 Resource Section
Insulating board behind external metal panels (as sample
AR000257)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
69Copperas Hill,
5th Floor, Revenue Management
Insulating board behind external metal panels (as sample
AR000257)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
70Copperas Hill,
5th Floor, Room 35 Classroom 3
Insulating board behind external metal panels (as sample
AR000257)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 26 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability)Asbestos
Fibre
Material Assessment
Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
71Copperas Hill, 5th Floor, Male toilet riser (26)
Insulating board lining to door Asbestos Insulating Board (Medium)
(1) Chrysotile 6 N/A N/A AR000272 Remove if likely to be
disturbed
72Copperas Hill, 5th Floor, Male toilet riser (26)
Loose gaskets Asbestos Textiles/Paper (Low)
(1) Chrysotile 4 N/A N/A AR000273 Remove if likely to be
disturbed
73Copperas Hill, 5th Floor, Male
toilets
Insulating board shuttering in ceiling void (as sample AR000267)
Asbestos Insulating Board (Medium)
(2) Amosite 8 N/A N/A AR000267 Restrict access and
remove
75Copperas Hill, 5th Floor, Male
toilets
Insulating board behind external metal panels (as sample
AR000257)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
76Copperas Hill,
5th Floor, Room 14 (33)
Insulating board ceiling and associated debris in ceiling void
Asbestos Insulating Board (Medium)
(2) Amosite 5 N/A N/A AR000275 Remove if likely to be
disturbed
77Copperas Hill,
5th Floor, Room 90 (38)
Insulating board partition in ceiling void
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000276 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 27 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability)Asbestos
FibreMaterial
Assessment Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
78Copperas Hill,
5th Floor, Room 59
Insulating board behind external metal panels (as sample AR000257)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
79Copperas Hill,
5th Floor, Rooms 58 and 57
Insulating board behind external metal panels (as sample AR000257)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
80Copperas Hill,
5th Floor, Rooms 56
Insulating board behind external metal panels (as sample AR000257)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
81Copperas Hill,
5th Floor, Rooms 55
Insulating board behind external metal panels (as sample AR000257)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
82Copperas Hill,
5th Floor, Room 54
Insulating board behind external metal panels (as sample AR000257)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
83Copperas Hill,
5th Floor, Room 53
Insulating board behind external metal panels (as sample AR000257)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 28 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability)Asbestos
Fibre
Material Assessment
Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
85Copperas Hill,
5th Floor, Room 73 Secure area (53)
Insulating board lining to door Asbestos Insulating Board (Medium)
(1) Chrysotile 6 N/A N/A AR000278 Remove if likely to be
disturbed
86Copperas Hill,
5th Floor, Room 73 Secure area (53)
Rope to pipe hanger in ceiling void
Asbestos Textiles/Paper
(Medium)
(1) Chrysotile 4 N/A N/A AR000279 Remove if likely to be
disturbed
89Copperas Hill,
5th Floor, Rooms 60 - 62
Insulating board behind external metal panels (as sample
AR000257)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
92Copperas Hill,
5th Floor, Rooms 65
Insulating board behind external metal panels (as sample
AR000257)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
95 Copperas Hill, 5th Floor, Room 66
Insulating board behind external metal panels (as sample
AR000257)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
99 Copperas Hill, 5th Floor, Room 68
Insulating boards behind external metal panels (as sample
AR000257)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 29 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability)Asbestos
Fibre
Material Assessment
Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
101 Copperas Hill, 5th Floor, Room 27
Insulating board partition in ceiling void (as sample AR000276)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000276 Remove if likely to be
disturbed
102Copperas Hill,
5th Floor, Corridor outside Room 23
Loose insulating board on top of ducting in ceiling void (as sample
AR000257)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
103Copperas Hill,
5th Floor, Corridor outside Room 23
Insulating board behind external metal panels (as sample AR000257)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
104 Copperas Hill, 5th Floor, Shop
Insulating board shuttering in ceiling void (as sample AR000267)
Asbestos Insulating Board (Medium)
(2) Amosite 8 N/A N/A AR000267 Remove if likely to be
disturbed
105Copperas Hill,
5th Floor, Shop (75)
Sink pad Well Bound Material (Low)
(1) Chrysotile 3 N/A N/A AR000286 Remove if likely to be
disturbed
106 Copperas Hill, 5th Floor, Shop
Insulating board behind external metal panels (as sample AR000257)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 30 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability) Asbestos FibreMaterial
Assessment Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
107Copperas Hill,
5th Floor, Room 22 Female WC (78)
Cement pipe in riser Asbestos Cement (Low)
(3) Crocidolite (or unknown) 5 N/A N/A - Remove if likely to be
disturbed
108Copperas Hill,
5th Floor, Room 4 Dining room/servery
Insulating board behind external metal panels (as sample
AR000257)
Asbestos Insulating Board
(Medium)(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
111Copperas Hill,
5th Floor, Room 4 Dining room/servery
IB cladding to steelwork in ceiling void (as sample
AR000276)
Asbestos Insulating Board
(Medium)(2) Amosite 7 N/A N/A AR000276 Remove if likely to be
disturbed
112Copperas Hill,
5th Floor, Room 18 Kitchen
IB cladding to steelwork in ceiling void and debris. (as
sample AR000276)
Asbestos Insulating Board
(Medium)(2) Amosite 8 N/A N/A AR000276 Remove if likely to be
disturbed
113Copperas Hill,
4th Floor Mezzanine Floor, Main lobby
AIB and metal infill above windows (as sample AR000257)
Asbestos Insulating Board
(Medium)(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
114Copperas Hill,
4th Floor Mezzanine Floor, Main riser (2)
Insulating board lining to doorAsbestos
Insulating Board (Medium)
(1) Chrysotile 5 N/A N/A AR000289 Remove if likely to be disturbed
Refurbishment & Demolition Surveys / J004560 Page 31 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability) Asbestos FibreMaterial
Assessment Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
115Copperas Hill,
4th Floor Mezzanine Floor, Main riser (2)
Mastic to wall joints (both rooms) Reinforced Composite (Low) (1) Chrysotile 2 N/A N/A AR000290 Remove if likely to be
disturbed
116
Copperas Hill, 4th Floor Mezzanine
Floor, Old server room
Insulating board shuttering in ceiling void (as sample
AR000267)
Asbestos Insulating Board (Medium) (2) Amosite 8 N/A N/A AR000267 Restrict access and
remove
117Copperas Hill,
4th Floor, Room 25 Lift Lobby
IB infill behind concrete to windows (as sample AR000257)
Asbestos Insulating Board (Medium) (2) Amosite 6 N/A N/A AR000257 Remove if likely to be
disturbed
118Copperas Hill,
4th Floor, Rooms 23 and 24 Toilets
Insulating board shuttering and infills in ceiling void (as sample
AR000267)
Asbestos Insulating Board (Medium) (2) Amosite 8 N/A N/A AR000267 Restrict access and
remove
119Copperas Hill,
4th Floor, Room 20 Riser Tower (3)
Durasteel cladding to wall (high and low level)
Asbestos Insulating Board (Medium)
(2) Chrysotile + Amosite 5 N/A N/A AR000291 Remove if likely to be
disturbed
120Copperas Hill,
4th Floor, Lift lobby riser (4)
Insulating board lining to door Asbestos Insulating Board (Medium) (1) Chrysotile 5 N/A N/A AR000292 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 32 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability) Asbestos FibreMaterial
Assessment Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
121Copperas Hill,
4th Floor, Room 19 OCR Training
Durasteel cladding to wall (as sample AR000291)
Asbestos Insulating Board (Medium)
(2) Chrysotile + Amosite 5 N/A N/A AR000291 Remove if likely to be
disturbed
122Copperas Hill,
4th Floor, Above Room 19
Durasteel partition behind plasterboard (as sample
AR000249)
Asbestos Insulating Board (Medium) (1) Chrysotile 4 N/A N/A AR000249 Remove if likely to be
disturbed
125Copperas Hill,
4th Floor, Room 23-24 Toilet Riser (17)
Insulating board lining to door Asbestos Insulating Board (Medium) (1) Chrysotile 5 N/A N/A AR000295 Remove if likely to be
disturbed
126Copperas Hill,
4th Floor, Room 36 Chain enclosure
Durasteel lining to sack conveyor (as sample
AR000249)
Asbestos Insulating Board (Medium) (1) Chrysotile 5 N/A N/A AR000249 Remove if likely to be
disturbed
127Copperas Hill,
4th Floor, Room 41 Lift Lobby
IB lining to double doors to room 56 (as sample AR000265)
Asbestos Insulating Board (Medium) (1) Chrysotile 5 N/A N/A AR000265 Remove if likely to be
disturbed
128Copperas Hill,
4th Floor, Riser adjacent room 41
Insulating board lining to door (as sample AR000292)
Asbestos Insulating Board (Medium) (1) Chrysotile 5 N/A N/A AR000292 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 33 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability)Asbestos
Fibre
Material Assessment
Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
129
Copperas Hill, 4th Floor, Riser adjacent room
55
Insulating board lining to door (as sample AR000292)
Asbestos Insulating Board (Medium)
(1) Chrysotile 5 N/A N/A AR000292 Remove if likely to be
disturbed
131Copperas Hill,
4th Floor, Room 54 Male WC
Cement flue pipe (as sample AR000246) Asbestos Cement (Low)
(1) Chrysotile 3 N/A N/A AR000246 Remove if likely to be
disturbed
132
Copperas Hill, 4th Floor, South West Lift Lobby
(26)
Recessed gasket to flange on fire hydrant pipework.
Asbestos Textiles/Paper
(Medium)
(1) Chrysotile 4 N/A N/A - Remove if likely to be
disturbed
134Copperas Hill,
4th Floor, Room 48 Male WC
Cement flue pipe (as sample AR000246) Asbestos Cement (Low)
(1) Chrysotile 3 N/A N/A AR000246 Remove if likely to be
disturbed
135Copperas Hill,
4th Floor, West Stair Lobby
IB lining to double doors to stairwell (as sample AR000265)
Asbestos Insulating Board (Medium)
(1) Chrysotile 5 N/A N/A AR000265 Remove if likely to be
disturbed
136
Copperas Hill, 4th Floor, Room 56, main floor
area
AIB cladding to lift motor room above lift LSG001 including AIB fillets to underlying
timber studs and noggins. (as sample AR000299)
Asbestos Insulating Board (Medium)
(2) Amosite 6 N/A N/A AR000299 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 34 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability)Asbestos
Fibre
Material Assessment
Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
137Copperas Hill,
4th Floor, Room 56, main floor area
AIB infill to ceiling expansion joints x2 (as sample AR000275)
Asbestos Insulating Board
(Medium)
(2) Amosite 5 N/A N/A AR000275 Remove if likely to be
disturbed
138Copperas Hill,
4th Floor, Room 56, main floor area
Durasteel fire hatch to chute adjacent to slide 1 (as sample
AR000249)
Asbestos Insulating Board
(Medium)
(1) Chrysotile 5 N/A N/A AR000249 Remove if likely to be
disturbed
139Copperas Hill,
4th Floor, Room 56, main floor area
Durasteel fire hatches to T, U and S chutes (as sample AR000249)
Asbestos Insulating Board
(Medium)
(1) Chrysotile 5 N/A N/A AR000249 Remove if likely to be
disturbed
141Copperas Hill,
4th Floor, Lift Moor Room for LSG001
AIB wall cladding on AIB fillets on timber studs and noggins. (as
sample AR000299)
Asbestos Insulating Board
(Medium)
(2) Amosite 8 N/A N/A AR000299 Remove if likely to be
disturbed
143
Copperas Hill, 3rd Floor Mezzanine
Floor, North Lift Lobby (1)
IB lining to double doors to stairwell.Asbestos
Insulating Board (Medium)
(1) Chrysotile 5 N/A N/A AR000309 Remove if likely to be
disturbed
144Copperas Hill,
3rd Floor Mezzanine Floor, North Lift Lobby
AIB window infills behind overspill concrete behind ceiling RSJ (as
sample AR000257)
Asbestos Insulating Board
(Medium)
(2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 35 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability) Asbestos FibreMaterial
Assessment Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
145
Copperas Hill, 3rd Floor Mezzanine
Floor, North Engineers Riser
IB lining to door (as sample AR000295)
Asbestos Insulating Board (Medium) (1) Chrysotile 5 N/A N/A AR000295 Remove if likely to be
disturbed
147
Copperas Hill, 3rd Floor Mezzanine Floor, North Locker
Room
Insulation board infills above windows x 3 (as sample
AR000257)
Asbestos Insulating Board (Medium) (2) Amosite 7 N/A N/A AR000257 Remove if likely to be
disturbed
148
Copperas Hill, 3rd Floor Mezzanine Floor, North Locker
Room (3)
Putty seal to HVAC ducting in ceiling void
Well Bound Material (Low) (1) Chrysotile 2 N/A N/A AR000298 Remove if likely to be
disturbed
149
Copperas Hill, 3rd Floor Mezzanine Floor, North Lockers
Riser
Brown mastic to walls (as sample AR000266)
Well Bound Material (Low) (1) Chrysotile 2 N/A N/A AR000266 Remove if likely to be
disturbed
150
Copperas Hill, 3rd Floor Mezzanine
Floor, Conveyor gallery (5)
AIB wall panels Asbestos Insulating Board (Medium) (2) Amosite 6 N/A N/A AR000299 Remove if likely to be
disturbed
153Copperas Hill,
3rd Floor Mezzanine Floor, Conveyor gallery
Durasteel airlock to chain exit (as sample AR000291)
Asbestos Insulating Board (Medium)
(2) Chrysotile + Amosite 5 N/A N/A AR000291 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 36 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability) Asbestos FibreMaterial
Assessment Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
154Copperas Hill,
3rd Floor Mezzanine Floor, Conveyor gallery
Durasteel floor hatches (as sample AR000249)
Asbestos Insulating Board (Medium) (1) Chrysotile 5 N/A N/A AR000249 Remove if likely to be
disturbed
155Copperas Hill,
3rd Floor Mezzanine Floor, Conveyor gallery
Durasteel boxing to conveyor feed from loading bay (as
sample AR000291)
Asbestos Insulating Board (Medium)
(2) Chrysotile + Amosite 5 N/A N/A AR000291 Remove if likely to be
disturbed
156
Copperas Hill, 3rd Floor Mezzanine
Floor, South East Male WC
Cement flue in riser (as sample AR000246)
Asbestos Cement (Low) (1) Chrysotile 3 N/A N/A AR000246 Remove if likely to be
disturbed
158
Copperas Hill, 3rd Floor Mezzanine
Floor, South West Lobby (12)
Gasket to fire riserAsbestos
Textiles/Paper (Medium)
(1) Chrysotile 4 N/A N/A - Remove if likely to be disturbed
162
Copperas Hill, 3rd Floor, Room 34
Entrance lobby/Reception (1)
Mastic to ventilation ducting in ceiling void
Reinforced Composite (Low) (1) Chrysotile 2 N/A N/A - Remove if likely to be
disturbed
163 Copperas Hill, 3rd Floor, Room 37
Insulating boarding to door lining (as sample AR000295)
Asbestos Insulating Board (Medium) (1) Chrysotile 5 N/A N/A AR000295 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 37 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability) Asbestos FibreMaterial
Assessment Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
165
Copperas Hill, 3rd Floor, Room 38 Loading Bays
(3)
IB infill to ceiling expansion joint and debris to conduit
Asbestos Insulating Board (Medium) (2) Amosite 8 N/A N/A AR000306 Remove if likely to be
disturbed
168Copperas Hill,
3rd Floor, Room 38 Loading Bays
IB wall cladding and fillets above G6 goods lift (as sample AR000299)
Asbestos Insulating Board (Medium) (2) Amosite 7 N/A N/A AR000299 Remove if likely to be
disturbed
169
Copperas Hill, 3rd Floor, Room 38 Loading Bays
(3)
Insulating board shuttering to ventilation duct
Asbestos Insulating Board (Medium) (2) Amosite 6 N/A N/A AR000312 Remove if likely to be
disturbed
170Copperas Hill,
3rd Floor, Room 38 Loading Bays
IB wall cladding and fillets above Eastern loading bay platforms & stores
(as sample AR000299)
Asbestos Insulating Board (Medium) (2) Amosite 6 N/A N/A AR000299 Remove if likely to be
disturbed
171Copperas Hill,
3rd Floor, Room 38 Loading Bays
Durasteel to chain enclosure (as sample AR000291)
Asbestos Insulating Board (Medium)
(2) Chrysotile + Amosite 5 N/A N/A AR000291 Remove if likely to be
disturbed
173
Copperas Hill, 3rd Floor, Room 38 Loading Bays
(3)
Mastic to ventilation duct jointing Reinforced Composite (Low) (1) Chrysotile 2 N/A N/A AR000310 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 38 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability) Asbestos FibreMaterial
Assessment Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
174Copperas Hill,
3rd Floor, Room 38 Loading Bays
Durasteel cladding to wall (as sample AR000291)
Asbestos Insulating Board (Medium)
(2) Chrysotile + Amosite 5 N/A N/A AR000291 Remove if likely to be
disturbed
175Copperas Hill,
3rd Floor, Room 38 Loading Bays
Durasteel cladding (high and low level) (as sample AR000291)
Asbestos Insulating Board (Medium)
(2) Chrysotile + Amosite 5 N/A N/A AR000291 Remove if likely to be
disturbed
176Copperas Hill,
3rd Floor, Room 36 Riser
Insulating board lining to door (as sample AR000289)
Asbestos Insulating Board (Medium) (1) Chrysotile 5 N/A N/A AR000289 Remove if likely to be
disturbed
177Copperas Hill,
3rd Floor, Room 33
Insulating board lining to door (as sample AR000289)
Asbestos Insulating Board (Medium) (1) Chrysotile 5 N/A N/A AR000289 Remove if likely to be
disturbed
178Copperas Hill,
3rd Floor, Room 43 Lobby (13)
Insulating board lining to door Asbestos Insulating Board (Medium) (1) Chrysotile 4 N/A N/A AR000313 Remove if likely to be
disturbed
186Copperas Hill,
3rd Floor, Rooms 1, 3, 4, 5
Insulating board lining to room 3 stairwell door (as sample
AR000313)
Asbestos Insulating Board (Medium) (1) Chrysotile 4 N/A N/A AR000313 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 39 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability) Asbestos FibreMaterial
Assessment Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
187Copperas Hill,
3rd Floor, Room 24 Sorting area
Mastic to ventilation duct joints (as sample
AR000312)
Asbestos Insulating Board (Medium) (2) Amosite 6 N/A N/A AR000312 Remove if likely to be
disturbed
188
Copperas Hill, 3rd Floor Mezzanine Floor, Throughout level 3 Mezz
(16)
Presumed asbestos in live electrics
Asbestos Textiles/Paper
(Medium)(1) Chrysotile 4 N/A N/A - Remove if likely to be
disturbed
189
Copperas Hill, 3rd Floor Mezzanine Floor, Room 18 Mezz plant room
(34)
Mastic to ventilation duct jointing
Reinforced Composite (Low) (1) Chrysotile 2 N/A N/A AR000318 Remove if likely to be
disturbed
190Copperas Hill,
3rd Floor Mezzanine Floor, Room 17 above G6 lift (17)
Floor tiles Reinforced Composite (Low) (1) Chrysotile 3 N/A N/A AR000319 Remove if likely to be
disturbed
191Copperas Hill,
3rd Floor Mezzanine Floor, Room 17 above G6 lift
Insulating board to walls (as sample AR000299)
Asbestos Insulating Board (Medium) (2) Amosite 6 N/A N/A AR000299 Remove if likely to be
disturbed
192Copperas Hill,
2nd Floor, Room 29 Boiler Room (1)
Insulating board shuttering to foul
chamber
Asbestos Insulating Board (Medium)
(2) Chrysotile + Amosite 7 N/A N/A AR000320 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 40 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability)Asbestos
FibreMaterial
Assessment ScorePriority
Assessment Score
Total Assessment
Score
Sample Number Recommendations
193Copperas Hill,
2nd Floor, Room 29 Boiler Room (1)
Dust/debris to floor channel Dust/Debris (High) (2) Amosite 11 N/A N/A AR000321 Remove if likely to be disturbed
195Copperas Hill,
2nd Floor, Room 29 Boiler Room (1)
Rope gasket to boilerAsbestos
Textiles/Paper (Medium)
(1) Chrysotile 4 N/A N/A AR000323 Remove if likely to be
disturbed
196Copperas Hill,
2nd Floor, Room 29 Boiler Room (1)
Rope gasket to boilerAsbestos
Textiles/Paper (Medium)
(1) Chrysotile 5 N/A N/A AR000324 Remove if likely to be
disturbed
197Copperas Hill,
2nd Floor, Room 29 Boiler Room (1)
Rope gasket to boilerAsbestos
Textiles/Paper (Medium)
(1) Chrysotile 4 N/A N/A AR000325 Remove if likely to be
disturbed
198Copperas Hill,
2nd Floor, Room 29 Boiler Room (1)
Presumed asbestos within electrics
Asbestos Textiles/Paper
(Medium)
(1) Chrysotile 4 N/A N/A - Inspect Prior to
Disturbance
199Copperas Hill,
2nd Floor, Room 29 Boiler Room
Gasket to front of boilers (as sample AR000324)
Asbestos Textiles/Paper
(Medium)
(1) Chrysotile 5 N/A N/A AR000324 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 41 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability)Asbestos
Fibre
Material Assessment
Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
203Copperas Hill,
2nd Floor, Room 29 Boiler Room (1)
Mastic to vent duct joints Reinforced Composite (Low)
(1) Chrysotile 2 N/A N/A AR000329 Remove if likely to be
disturbed
205Copperas Hill,
2nd Floor, Room 29 Boiler Room (1)
No access within plantAsbestos
Textiles/Paper (Medium)
(1) Chrysotile 4 N/A N/A - Inspect Prior to
Disturbance
208Copperas Hill,
2nd Floor, Lift lobby x2 S/W Tower
IB door lining (as sample AR000309)
Asbestos Insulating Board (Medium)
(1) Chrysotile 5 N/A N/A AR000309 Remove if likely to be
disturbed
212Copperas Hill,
2nd Floor, Main Corridor (6)
Gaskets to pipeworkAsbestos
Textiles/Paper (Medium)
(1) Chrysotile 4 N/A N/A - Remove if likely to be
disturbed
214Copperas Hill,
2nd Floor, Rooms 19-23
Mastic to ventilation duct flange (as sample AR000329)
Reinforced Composite (Low)
(1) Chrysotile 2 N/A N/A AR000329 Remove if likely to be
disturbed
217Copperas Hill,
2nd Floor, Rooms 17 and 18
IB door lining to chute riser (as sample AR000313)
Asbestos Insulating Board (Medium)
(1) Chrysotile 4 N/A N/A AR000313 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 42 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability)Asbestos
Fibre
Material Assessment
Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
219Copperas Hill,
2nd Floor, Room 2 Cleaners (West)
IB door lining (as sample AR000313)
Asbestos Insulating Board (Medium)
(1) Chrysotile 4 N/A N/A AR000313 Remove if likely to be
disturbed
220Copperas Hill,
2nd Floor, Lift lobby West Tower
IB door lining (as sample AR000309)
Asbestos Insulating Board (Medium)
(1) Chrysotile 5 N/A N/A AR000309 Remove if likely to be
disturbed
222Copperas Hill,
2nd Floor, Room 6 Addressograph Store (15)
Vinyl floor tiles and bitumen adhesive below
Reinforced Composite (Low)
(1) Chrysotile 3 N/A N/A AR000334 Remove if likely to be
disturbed
223Copperas Hill,
2nd Floor, Room 6 Addressograph Store (15)
Lining to doors to stairs (visible)
Asbestos Insulating Board (Medium)
(2) Amosite 5 N/A N/A - Remove if likely to be
disturbed
224
Copperas Hill, 2nd Floor, Rooms 7-9, 14-15
Classrooms 1 and 2 and adjacent
Vinyl floor tiles and bitumen adhesive below (as sample
AR000334)
Reinforced Composite (Low)
(1) Chrysotile 3 N/A N/A AR000334 Remove if likely to be
disturbed
225
Copperas Hill, 2nd Floor, Rooms 10 - 13
Callers Office and associated areas
Vinyl floor tiles and bitumen adhesive below (as sample
AR000334)
Reinforced Composite (Low)
(1) Chrysotile 3 N/A N/A AR000334 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 43 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability)Asbestos
Fibre
Material Assessment
Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
228 Copperas Hill, 2nd Floor, Room 35 - 36
CAF gaskets to pipework and compressor pipes (as sample
AR000258)
Asbestos Textiles/Paper (Low)
(1) Chrysotile 3 N/A N/A AR000258 Remove if likely to be
disturbed
229Copperas Hill,
2nd Floor, Room 35 - 36 (18)
Electrical switch boxes presumed as live
Asbestos Textiles/Paper
(Medium)
(1) Chrysotile 5 N/A N/A - Remove if likely to be
disturbed
230
Copperas Hill, 2nd Floor, Fume Extract and Plenum Chamber
(accessed via 37)
Mastic to ventilation duct flanges (as sample AR000254)
Reinforced Composite (Low)
(1) Chrysotile 2 N/A N/A AR000254 Remove if likely to be
disturbed
231
Copperas Hill, 2nd Floor, Fume Extract and Plenum Chamber
(accessed via 37)
Mastic to wall expansion joint (as sample AR000266)
Well Bound Material (Low)
(1) Chrysotile 2 N/A N/A AR000266 Remove if likely to be
disturbed
233
Copperas Hill, 2nd Floor, Fume Extract and Plenum Chamber
(accessed via 37)
IB shuttering to duct ceiling (as sample AR000312)
Asbestos Insulating Board (Medium)
(2) Amosite 6 N/A N/A AR000312 Remove if likely to be
disturbed
234
Copperas Hill, 2nd Floor, Room 29a
Engineers Workshop and 30 Electric
IB panels to concrete upper expansion joint. (as sample
AR000306)
Asbestos Insulating Board (Medium)
(2) Amosite 8 N/A N/A AR000306 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 44 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability) Asbestos FibreMaterial
Assessment Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
235
Copperas Hill, 2nd Floor, Room 29a
Engineers Workshop and 30 Electric
CAF gaskets to pipework (as sample AR000258)
Asbestos Textiles/Paper (Low) (1) Chrysotile 3 N/A N/A AR000258 Remove if likely to be
disturbed
236
Copperas Hill, 2nd Floor, Room 29a
Engineers Workshop and 30 Electric
Mastic to wall expansion joints (as sample
AR000266)
Well Bound Material (Low) (1) Chrysotile 2 N/A N/A AR000266 Remove if likely to be
disturbed
238
Copperas Hill, 2nd Floor, Room 29a
Engineers Workshop and 30 Electric (20)
Resin panel to electrical switch gear
Well Bound Material (Low) (1) Chrysotile 3 N/A N/A AR000338 Remove if likely to be
disturbed
239
Copperas Hill, 2nd Floor, Room 29a
Engineers Workshop and 30 Electric
Mastic to ventilation duct flanges (as sample
AR000254)
Reinforced Composite (Low) (1) Chrysotile 2 N/A N/A AR000254 Remove if likely to be
disturbed
240Copperas Hill,
2nd Floor, Room 38 and 39 (21)
Presumed CAF and rope gaskets machinery and
pipework
Asbestos Textiles/Paper
(Medium)(1) Chrysotile 5 N/A N/A - Inspect Prior to
Disturbance
243 Copperas Hill, 2nd Floor, Room 24 - 27
IB shuttering to foul drain (as sample AR000320)
Asbestos Insulating Board (Medium)
(2) Chrysotile + Amosite 7 N/A N/A AR000320 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 45 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability)Asbestos
Fibre
Material Assessment
Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
245
Copperas Hill, External, Plant Room and
Substation External Canopy (17)
CAF gasket to pipeworkAsbestos
Textiles/Paper (Medium)
(1) Chrysotile 5 N/A N/A AR000340 Remove if likely to be
disturbed
246Copperas Hill,
1st Floor, Room 12 Lift lobby
IB door linings (as sample AR000313)
Asbestos Insulating Board (Medium)
(1) Chrysotile 4 N/A N/A AR000313 Remove if likely to be
disturbed
247Copperas Hill,
1st Floor, Room 11 and 13 Sensitive Waste
IB infill above door and loose to floor and in ceiling void (as
sample AR000257)
Asbestos Insulating Board (Medium)
(2) Amosite 8 N/A N/A AR000257 Remove if likely to be
disturbed
248Copperas Hill,
1st Floor, Room 11 and 13 Sensitive Waste
IB door lining (as sample AR000272)
Asbestos Insulating Board (Medium)
(1) Chrysotile 6 N/A N/A AR000272 Remove if likely to be
disturbed
250 Copperas Hill, 1st Floor, Room 3 and 10
IB door lining (as sample AR000313)
Asbestos Insulating Board (Medium)
(1) Chrysotile 4 N/A N/A AR000313 Remove if likely to be
disturbed
253 Copperas Hill, 1st Floor, Room 4
IB door lining (as sample AR000309)
Asbestos Insulating Board (Medium)
(1) Chrysotile 5 N/A N/A AR000309 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 46 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability)Asbestos
FibreMaterial
Assessment Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
254Copperas Hill,
1st Floor, West Tower Corridor
IB door linings (as sample AR000313)
Asbestos Insulating Board (Medium)
(1) Chrysotile 4 N/A N/A AR000313 Remove if likely to be
disturbed
258Copperas Hill,
Lift Shaft, P1-3 Passenger Lift (4)
IB wall panels Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000344 Remove if likely to be
disturbed
259Copperas Hill,
Lift Shaft, P1-3 Passenger Lift (4)
Mastic to wall expansion joint
Well Bound Material (Low)
(1) Chrysotile 3 N/A N/A AR000345 Remove if likely to be
disturbed
260Copperas Hill,
External, West Tower Loading bay (Level 1) (18)
Millboard canopy above loading bay doors
Asbestos Insulating Board (Medium)
(1) Chrysotile 7 N/A N/A AR000357 Remove if likely to be
disturbed
261Copperas Hill,
1st Floor, Throughout Level 1 ()
Presumed ACM's to live electrics
Asbestos Textiles/Paper
(Medium)
(1) Chrysotile 6 N/A N/A - Inspect Prior to
Disturbance
262Copperas Hill,
2nd Floor, Throughout Level 2 ()
Presumed ACM's to live electrics
Asbestos Textiles/Paper
(Medium)
(1) Chrysotile 6 N/A N/A - Inspect Prior to
Disturbance
Refurbishment & Demolition Surveys / J004560 Page 47 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability)Asbestos
Fibre
Material Assessment
Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
263 Copperas Hill, 3rd Floor, Throughout Level 3 ()
Presumed ACM's to live electrics
Asbestos Textiles/Paper
(Medium)
(1) Chrysotile 6 N/A N/A - Inspect Prior to
Disturbance
265
Copperas Hill, 4th Floor Mezzanine Floor, 4mw1 - 4mw3 (4m West
Tower)
IB door lining (as sample AR000265)
Asbestos Insulating Board (Medium)
(1) Chrysotile 6 N/A N/A AR000265 Remove if likely to be
disturbed
266
Copperas Hill, 4th Floor Mezzanine Floor,
4msw1-4msw3 (4m South West Tower)
Cement flue pipe in toilet riser (as sample
AR000246)
Asbestos Cement (Low)
(1) Chrysotile 4 N/A N/A AR000246 Remove if likely to be
disturbed
267
Copperas Hill, 4th Floor Mezzanine Floor,
4msw1-4msw3 (4m South West Tower)
IB door lining to stairwell (as sample AR000265)
Asbestos Insulating Board (Medium)
(1) Chrysotile 6 N/A N/A AR000265 Remove if likely to be
disturbed
268
Copperas Hill, 4th Floor Mezzanine Floor, 4mse1- 4mse 3a,b & c (4m
South East Tower)
IB door lining to stairwell (as sample AR000265)
Asbestos Insulating Board (Medium)
(1) Chrysotile 6 N/A N/A AR000265 Remove if likely to be
disturbed
269
Copperas Hill, 4th Floor Mezzanine Floor, 4mse1- 4mse 3a,b & c (4m
South East Tower)
Cement flue pipe in toilet riser (as sample
AR000246)
Asbestos Cement (Low)
(1) Chrysotile 4 N/A N/A AR000246 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 48 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability)Asbestos
Fibre
Material Assessment
Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
270
Copperas Hill, 3rd Floor, Conveyor
to Tunnel (Riser Tower)
Durasteel wall infills (as sample AR000249)
Asbestos Insulating Board (Medium)
(1) Chrysotile 6 N/A N/A AR000249 Remove if likely to be
disturbed
271
Copperas Hill, 3rd Floor, Conveyor
to Tunnel (Riser Tower)
Mastic to ventilation duct flange joints (as sample AR000254)
Reinforced Composite (Low)
(1) Chrysotile 3 N/A N/A AR000254 Remove if likely to be
disturbed
272
Copperas Hill, 3rd Floor, Conveyor
to Tunnel (Riser Tower)
CAF gaskets to pipework (as sample AR000258)
Asbestos Textiles/Paper (Low)
(1) Chrysotile 5 N/A N/A AR000258 Remove if likely to be
disturbed
273
Copperas Hill, 2nd Floor, Conveyor
to Tunnel (Riser Tower)
IB lining to door (as sample AR000264)
Asbestos Insulating Board (Medium)
(1) Chrysotile 6 N/A N/A AR000264 Remove if likely to be
disturbed
274
Copperas Hill, 3rd Floor, Conveyor
to Tunnel (Riser Tower)
Durasteel panel within mail chute - No access to sample (as sample
AR000246)
Asbestos Cement (Medium)
(1) Chrysotile 5 N/A N/A AR000246 Inspect Prior to
Disturbance
275Copperas Hill,
5th Floor, Rooms 48, 49, 51, 52
IB cladding above window in ceiling void (Room 48-49 Customer Services)
(as sample AR000276)
Asbestos Insulating Board (Medium)
(2) Amosite 7 N/A N/A AR000276 Remove if likely to be
disturbed
Refurbishment & Demolition Surveys / J004560 Page 49 of 386
...................................................................................................................................Liverpool John Moores University
Inspection Number Area Feature Material Type –
(Friability)Asbestos
Fibre
Material Assessment
Score
Priority Assessment
Score
Total Assessment
Score
Sample Number Recommendations
276Copperas Hill,
5th Floor, Room 70 Non Smoking Lounge
IB beam cladding in ceiling void above window (Room 70 & Room
5) (as sample AR000276)
Asbestos Insulating Board
(Medium)
(2) Amosite 7 N/A N/A AR000276 Remove if likely to be
disturbed
277
Copperas Hill, External, Window Infills (Behind Brown Panels)
(External)
Ib window infill panels (as sample AR000257)
Asbestos Insulating Board
(Medium)
(2) Amosite 6 N/A N/A AR000257 Remove if likely to be
disturbed
279
Copperas Hill, 2nd Floor Mezzanine Floor, Vehicle Exhaust Duct - South
(Lower) (2M-001)
Insulating board shuttering panels to ceiling (as sample BS021508)
Asbestos Insulating Board
(Medium)
(2) Amosite 9 N/A N/A BS021508 Repair and/or
Encapsulate
280
Copperas Hill, 2nd Floor Mezzanine Floor, Vehicle Exhaust Duct - North
West (Upper) (2M-002)
Insulating board shuttering panels to ceiling (as sample BS021508)
Asbestos Insulating Board
(Medium)
(2) Amosite 9 N/A N/A BS021508 Repair and/or
Encapsulate
281
Copperas Hill, 2nd Floor Mezzanine Floor, Vehicle Exhaust Duct - North
(Upper) (2M-003)
Insulating board shuttering panels to ceiling (as sample BS021508)
Asbestos Insulating Board
(Medium)
(2) Amosite 9 N/A N/A BS021508 Repair and/or
Encapsulate
282
Copperas Hill, 2nd Floor Mezzanine Floor, Vehicle Exhaust Duct - East
(Lower) (2M-004)
Insulating board shuttering to ceiling (as sample BS021508)
Asbestos Insulating Board
(Medium)
(2) Amosite 9 N/A N/A BS021508 Repair and/or
Encapsulate
Refurbishment & Demolition Surveys / J004560 Page 50 of 386
...................................................................................................................................Liverpool John Moores University
6.0 Recommendations
6.1 Summary
Survey inspection reports detail the ACM identified, its approximate extent and its priority risk rating, these reports are contained within Appendix B of this report. The asbestos register, Section 5.0 of this report summarises asbestos containing materials and presumed asbestos materials identified during the course of the survey.
Priority assessments provided are outside the scope of our UKAS accreditation.
6.2 Mastic to Wall Joints
Mastic was identified to wall joints in area 3 Lift Lobby Riser on the 5th floor. The material is sporadic and intermittent throughout the floor. This material should be presumed to be present to all floors.
6.2 Further Investigation
There is a possibility that asbestos material may be present in those areas that were concealed or inaccessible at the time of the survey or fell outside the scope of this investigation. Prior to demolition, refurbishment or any activity that disturbs the fabric of the building outside the scope of this survey it is recommended that a fully intrusive WYG Asbestos Refurbishment or Demolition survey be conducted, under controlled conditions where appropriate.
Prior to the application of a WYG Asbestos Refurbishment or Demolition survey all areas of the site should be approached with caution during any future works, we suggest that the contractor has an appropriate method statement in place such that if suspected asbestos materials are encountered, a sample can be taken to confirm the nature of the material prior to any work in that area.
6.3 General
If asbestos removal is required, it is recommended that a site–specific asbestos removal specification and method statements be produced in order to facilitate any asbestos removal works.
The waste generated from asbestos removal should be notified and disposed of in accordance with the Hazardous Waste (England & Wales) Regulations 2005, Amended 2009.
The contractor must ensure that adequate Duty of Care provisions are put in place for the transportation and disposal of wastes from the site in line with the obligations of the Environmental Protection Act 1990.
In accordance with Regulation 4 of The Control of Asbestos Regulations 2012, it is advised that a management plan is produced and a duty holder be appointed to coordinate and oversee the management of the asbestos at the site.
Where asbestos insulation materials are removed, the building manager should ensure that non–asbestos replacement materials are installed, to maintain fire proofing.
If asbestos containing materials (ACM’s) are to remain in–situ across the premises, CAR 2012 requires a Duty Holder be appointed/identified, who will be responsible for producing and implementing an Asbestos Management Plan, as defined by HSG 227.
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 51 of 386
.......................................................................................
Due to the nature of a WYG Asbestos Refurbishment / Demolition Survey there is always the possibility of asbestos being present within inaccessible areas and those areas outlined within Sections 4.2 and 4.3 of the report as outside the scope of this type of survey. If any work is to be carried out within these areas then materials encountered should be presumed to contain asbestos unless there is strong evidence for a reasoned argument that the material does not contain asbestos. This can be achieved by taking a sample and having subsequent analysis undertaken on the sample in accordance with HSG 248.
Prior to demolition, refurbishment or any other works that might disturb the asbestos materials identified, they should be removed. It is recommended that a site–specific method statement be produced in order to facilitate the removal of the asbestos. It is advised that a competent person be appointed to coordinate and oversee the management of asbestos at the site.
The detailed extent of asbestos materials presented in this report are approximate values only and should not be used in isolation to prepare quotations for asbestos repair or removal. It is recommended that any asbestos repair or removal be evaluated by an asbestos removal contractor, who should attend site to confirm the extent of asbestos.
6.4 Asbestos Management Plan (AMP)
The Control of Asbestos Regulations 2012 stipulates under Regulation 4, that persons responsible by virtue of ownership, contract or tenancy of a non–domestic premise are responsible for undertaking a suitable and sufficient assessment for the presence of asbestos materials within those premises and implement an appropriate Asbestos Management Plan (AMP).
Areas highlighted in Sections 4.2 and 4.3 as areas of ‘no access’ should be presumed to contain amphibole asbestos and appropriate management planning should be implemented in order to control access and maintenance activities to these areas until such a time as they can be accessed and the presence or absence of asbestos containing materials can be confirmed.
Asbestos materials were encountered in the survey as detailed in Section 5.0. The AMP should stipulate the requirements for working in these areas identified as containing asbestos as well as the areas of ‘no access’ as stated in Sections 4.2 and 4.3. For example the requirements for working in these areas may be a permit to work system, appropriate risk assessments or by other means to ensure people are not exposed to asbestos. (Remove if negative report)
Consultation of the Approved Code of Practice L127: The management of asbestos in non–domestic premises outlines the procedures that should be followed when developing and implementing an AMP.
In accordance with Regulation 4 of The Control of Asbestos Regulations 2012, it is advised that a ‘Duty Holder’ be appointed to coordinate and oversee the management of asbestos at the site. The most appropriate person to be considered to be a Duty Holder is the person responsible for coordinating maintenance activities for the premises.
The Duty Holder has the responsibility to incorporate the results of this survey into an AMP for the building. The Duty Holder must ensure that an appropriate Priority Assessment is undertaken as detailed in HSG 227: A Comprehensive Guide to Managing Asbestos in Premises, taking into account factors such as:
● Normal Occupant Activity – assessment based upon the interaction of occupants and the area being assessed. ● Likelihood of disturbance – assessment based upon location of asbestos, its accessibility and quantity of
material that has the potential to be disturbed. ● Human Exposure Potential – assessment based upon number of occupants, frequency of use and duration of
use.
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 52 of 386
.......................................................................................
● Maintenance Activity – assessment based upon type of maintenance activity and frequency.
Combining the Material Risk Assessment with the Priority Assessment provides an overall assessment with respect to ACM’s present within a building. This overall assessment will then determine the management requirements for the building.
Priority assessments provided are outside the scope of our UKAS accreditation.
WYG can assist in the process of risk assessment to further develop the AMP in accordance with L127 and HSG 227.
6.5 MMMF
A number of materials associated with Machine Made Mineral Fibre (MMMF) are present with areas in the building (e.g. within ceiling voids). These materials are covered by the COSHH regulations and persons working on or near these materials should undertake sufficient risk assessments and/or wear appropriate Personal Protective Equipment.
6.6 Fire Protection
Where asbestos insulation materials are removed, the building manager should ensure that non–asbestos replacement materials are installed, to maintain fire proofing.
If fire–rated materials are removed there may be a requirement to review and revise the site Fire Risk Assessment. WYG has a dedicated Fire Risk Assessment team, who would be pleased to provide further guidance in this respect required.
6.7 Other Safety Management and Compliance Services
We provide a range of safety management and compliance services to a variety of clients across the public and private sector. Services include:
Health and Safety Management
● Development and implementation of safety management systems such as OHSAS 18001, BS8800, HSG65 ● Advice on preparing effective health and safety policies, procedures and systems of work ● Risk assessments (including workplace and work activity, manual handling, display screen equipment (DSE),
CoSHH etc) ● Advice on setting key performance indicators for driving improvements in safety performance ● Accident and incident investigation ● Independent compliance audits ● Occupational exposure monitoring – dusts, fumes, vapours, etc ● Noise monitoring and noise control ● Indoor air quality and working environment investigation.
Legionella Assessment
● L8 compliant Legionella risk assessments ● Legionella awareness seminars and training ● Independent compliance audits
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 53 of 386
.......................................................................................
CDM Co–ordinator Services
● Full proactive CDM co–ordinator service on notifiable projects of all sizes ● Client’s construction health and safety advisor for non–notifiable projects ● Design of health and safety risk workshops ● CDM regulations compliance audits of all duty holders.
Fire and Explosion
● Regulatory reform (fire safety) order compliant fire risk assessments ● Expert advice on means of escape, structural protection, automatic detection and fire fighting systems ● Liaison with enforcing authorities ● Dangerous substances and explosive atmospheres regulations (DSEAR) risk assessment
Training
● Institution of occupational safety and health accredited courses: ● Directing safely ● Managing safely ● Working safely ● Executive update – key health and safety legislative requirements ● Health & safety responsibilities of line managers ● H&S risk assessments – a practical approach ● DSE safety and user awareness ● Handling loads, preventing injury – good manual handling practice ● COSHH assessment, assessor training ● CDM Regulations 2007 – introduction ● CDM Regulations 2007 for designers ● Asbestos awareness & training for non–licensable activities.
Asbestos Consultancy
● Asbestos surveys (management, refurbishment & demolition surveys) ● Removal specifications ● On–site inspection and monitoring of works ● Asbestos management plans ● Completion and validation reporting ● Asbestos awareness seminars and training ● Expert witness
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 54 of 386
.......................................................................................
7.0 Glossary of Terms
ACM Asbestos Containing Material
AIB Asbestos Insulating Board
AMP Asbestos Management Plan
CAR Control of Asbestos Regulations
EA Environment Agency
HSE Health and Safety Executive
HSG Health and Safety Guidance
MMMF Machine Made Mineral Fibre
NADIS No Asbestos Detected in Sample
UKAS United Kingdom Accreditation Service
WYG WYG Environment Planning Transport Ltd
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 55 of 386
.......................................................................................
8.0 References
HSG 264 Asbestos: The Survey Guide, 2nd Edition, 2012
HSG 248 Asbestos: The Analysts Guide for Sampling, Analysis and Clearance Procedures, 2005.
CAR 2012 Control of Asbestos Regulations 2012, April 2012.
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 56 of 386
.......................................................................................
Appendices
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 57 of 386
.......................................................................................
Appendix A – Report Conditions for WYG Asbestos Refurbishment / Demolition Survey
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 58 of 386
.......................................................................................
This report is produced solely for the benefit of Liverpool John Moores University, no account is taken for any reliance placed on it by any other party unless specifically agreed in writing otherwise.
This report refers, within the limitations stated, to the condition of the site at the time of the inspections. No warranty is given as to the possibility of future changes in the condition of the site.
This report is based on a site inspection in the accessed areas as noted, the physical investigation as detailed, information supplied by those parties referenced in the text. Some of the opinions are based on unconfirmed data and information and are presented as the best that can be obtained without further extensive dismantling and disturbance. The test results that are available can only be regarded as a limited but likely representative sample assessed against current guidelines. The impact of our assessment on other aspects of the development requires evaluation by other involved parties. The possibility of the presence of asbestos, perhaps in higher concentrations, elsewhere on the site, cannot be discounted.
Whilst the findings detailed within this report reflect our best assessment, because there are no exact UK definitions of these matters, being subject to risk analysis, we are unable to give categoric assurances that they will be accepted by authorities or funds without question as such bodies have unpublished, more stringent objectives. This report is prepared and written for the purposed uses stated in the report and should not be used in a different context without reference to WYG. In time improved practices or amended legislation may necessitate a re–assessment.
The report is limited to those aspects specifically reported on and is necessarily restricted and no liability is accepted for any other aspect. The opinions expressed cannot be absolute due to the limitations of time and resources accepted by the agreed brief and the possibility of unrecorded previous use and abuse of the site and adjacent sites. The report concentrates on the site as defined in the report.
WYG ENVIRONMENT PLANNING TRANSPORT LTD
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 59 of 386
.......................................................................................
Appendix B – Inspection Reports Priority assessments provided are outside the scope of our UKAS accreditation
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 60 of 386
.......................................................................................
Inspection Number 1 Reference Number: AR000237
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level External
Area / Room 1 Roof room 3 tank room
Feature Residue to pipe work
Product Type Insulation
Extent Amount 4 m
Recommendation
Product Score High Fibre Release - Thermal insulation (e.g. pipe and boiler lagging) sprayed asbestos, loose asbestos, asbestos mattresses and packing
0
Extent of Damage High damage - or delamination of materials, sprays and thermal insulation. Visible asbestos debris
0
Surface Treatment Unsealed lagging and sprays 0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 2 Reference Number: AR000238
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level External
Area / Room 1 Roof room 3 tank room
Feature Residue to pipe work
Product Type Insulation
Extent Amount 4 m
Recommendation
Product Score High Fibre Release - Thermal insulation (e.g. pipe and boiler lagging) sprayed asbestos, loose asbestos, asbestos mattresses and packing
0
Extent of Damage High damage - or delamination of materials, sprays and thermal insulation. Visible asbestos debris
0
Surface Treatment Unsealed lagging and sprays 0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 3 Reference Number: AR000239
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level External
Area / Room 1 Roof room 3 tank room
Feature Debris to floor
Product Type Insulation
Extent Amount 12 m
Recommendation
Product Score High Fibre Release - Thermal insulation (e.g. pipe and boiler lagging) sprayed asbestos, loose asbestos, asbestos mattresses and packing
0
Extent of Damage High damage - or delamination of materials, sprays and thermal insulation. Visible asbestos debris
0
Surface Treatment Unsealed lagging and sprays 0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 4 Reference Number: AR000240
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level External
Area / Room 1 Roof room 3 tank room
Feature Debris to floor
Product Type Insulation
Extent Amount 12 m
Recommendation
Product Score High Fibre Release - Thermal insulation (e.g. pipe and boiler lagging) sprayed asbestos, loose asbestos, asbestos mattresses and packing
0
Extent of Damage High damage - or delamination of materials, sprays and thermal insulation. Visible asbestos debris
0
Surface Treatment Unsealed lagging and sprays 0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 5 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Presumed
Notes
Building Copperas Hill
Floor Level External
Area / Room 1 Roof room 3 tank room
Feature Presumed asbestos in live electrics
Product Type Asbestos Textiles/Paper
Extent Amount 1 no.
Recommendation Inspect Prior to Disturbance
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 6 Reference Number: AR000241
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level External
Area / Room 2 Roof room 4 lift motor room
Feature Mastic around door
Product Type Well Bound Material
Extent Amount 3 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 7 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Presumed
Notes
Building Copperas Hill
Floor Level External
Area / Room 2 Roof room 4 lift motor room
Feature Presumed asbestos in live electrics
Product Type Asbestos Textiles/Paper
Extent Amount 1 no.
Recommendation Inspect Prior to Disturbance
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 8 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Presumed
Notes
Building Copperas Hill
Floor Level External
Area / Room 3 Roof room 6 lift motor room
Feature Presumed asbestos in live electrics
Product Type Asbestos Textiles/Paper
Extent Amount 1 no.
Recommendation Inspect Prior to Disturbance
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 9 Reference Number: AR000243
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level External
Area / Room 3 Roof room 6 lift motor room
Feature Insulating board lining to door
Product Type Insulating Board
Extent Amount 4 m
Recommendation
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 10 Reference Number: AR000244
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level External
Area / Room 4 Roof room 5 tank room
Feature Residue to pipe work
Product Type Insulation
Extent Amount 4 m
Recommendation
Product Score High Fibre Release - Thermal insulation (e.g. pipe and boiler lagging) sprayed asbestos, loose asbestos, asbestos mattresses and packing
0
Extent of Damage High damage - or delamination of materials, sprays and thermal insulation. Visible asbestos debris
0
Surface Treatment Unsealed lagging and sprays 0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 11 Reference Number: AR000245
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level External
Area / Room 4 Roof room 5 tank room
Feature Debris to floor
Product Type Insulation
Extent Amount 12 m
Recommendation
Product Score High Fibre Release - Thermal insulation (e.g. pipe and boiler lagging) sprayed asbestos, loose asbestos, asbestos mattresses and packing
0
Extent of Damage High damage - or delamination of materials, sprays and thermal insulation. Visible asbestos debris
0
Surface Treatment Unsealed lagging and sprays 0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 12 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Presumed
Notes
Building Copperas Hill
Floor Level External
Area / Room 4 Roof room 5 tank room
Feature Presumed asbestos in live electrics
Product Type Asbestos Textiles/Paper
Extent Amount 1 no.
Recommendation Inspect Prior to Disturbance
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 13 Reference Number: AR000246
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level External
Area / Room 4 Roof room 5 tank room
Feature Cement pipe and jointing
Product Type Asbestos Cement
Extent Amount 3 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 3 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 14 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Presumed
Notes
Building Copperas Hill
Floor Level External
Area / Room 5 Roof room 7a lift motor room
Feature Presumed asbestos in live electrics
Product Type Asbestos Textiles/Paper
Extent Amount 2 no.
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 15 Reference Number: AR000247
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level External
Area / Room 5 Roof room 7a lift motor room
Feature Insulating board lining to door
Product Type Asbestos Insulating Board
Extent Amount 4 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 16 Reference Number: AR000248
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level External
Area / Room 5 Roof room 7a lift motor room
Feature Bitumen in door frame
Product Type Well Bound Material
Extent Amount 4 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Medium damage - significant breakage of materials or several small areas where material has been damaged revealing loose asbestos fibres
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 17 Reference Number: As Sample AR000247
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level External
Area / Room 6 Roof room 7b tank room
Feature Insulating board lining to door
Product Type Asbestos Insulating Board
Extent Amount 4 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 18 Reference Number: As Sample AR000248
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level External
Area / Room 6 Roof room 7b tank room
Feature Bitumen behind door frame
Product Type Well Bound Material
Extent Amount 4 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Medium damage - significant breakage of materials or several small areas where material has been damaged revealing loose asbestos fibres
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 19 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Presumed
Notes
Building Copperas Hill
Floor Level External
Area / Room 7 Riser tower lift motor room
Feature Presumed asbestos in live electrics
Product Type Asbestos Textiles/Paper
Extent Amount 1 no.
Recommendation Inspect Prior to Disturbance
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 20 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Strongly Presumed
Notes
Building Copperas Hill
Floor Level External
Area / Room 7 Riser tower lift motor room
Feature Asbestos brake shoes in lift motor
Product Type Asbestos Cement
Extent Amount 1 no.
Recommendation Inspect Prior to Disturbance
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Crocidolite (or unknown) 3
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 6 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 21 Reference Number: AR000249
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level External
Area / Room 7 Riser tower lift motor room
Feature Durasteel trap doors
Product Type Asbestos Insulating Board
Extent Amount 4 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 22 Reference Number: As Sample AR000249
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level External
Area / Room 8 Riser tower lift motor room lower level
Feature Durasteel trap doors to ceiling
Product Type Asbestos Insulating Board
Extent Amount 4 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 23 Reference Number: AR000251
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level External
Area / Room 9 Roof lift motor room 2
Feature Cladding to beams
Product Type Insulating Board
Extent Amount 16 m
Recommendation
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 24 Reference Number: AR000252
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level External
Area / Room 9 Roof lift motor room 2
Feature Floor tiles
Product Type Reinforced Composite
Extent Amount 40 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 2 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 25 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Strongly Presumed
Notes
Building Copperas Hill
Floor Level External
Area / Room 9 Roof lift motor room 2
Feature Brake shoes in lift motors
Product Type Asbestos Cement
Extent Amount 3 no.
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Crocidolite (or unknown) 3
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 26 Reference Number: AR000253
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level External
Area / Room 9 Roof lift motor room 2
Feature Mastic to wall column joints
Product Type Reinforced Composite
Extent Amount 40 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 27 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Presumed
Notes
Building Copperas Hill
Floor Level External
Area / Room 9 Roof lift motor room 2
Feature Presumed asbestos in live electrics
Product Type Asbestos Textiles/Paper
Extent Amount 3 no.
Recommendation Inspect Prior to Disturbance
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 28 Reference Number: As Sample AR000253
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level External
Area / Room 10 Roof lift motor room 2 lobby
Feature Mastic to wall joints
Product Type Reinforced Composite
Extent Amount 4 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 29 Reference Number: As Sample AR000264
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level External
Area / Room 10 Roof lift motor room 2 lobby
Feature Insulating board lining to doors
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 30 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Presumed
Notes
Building Copperas Hill
Floor Level External
Area / Room 11 Roof lift motor room 2 Lobby Riser Tower
Feature Presumed asbestos in live electrics
Product Type Asbestos Textiles/Paper
Extent Amount 1 no.
Recommendation Inspect Prior to Disturbance
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 31 Reference Number: AR000264
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes x2 Doors
Building Copperas Hill
Floor Level External
Area / Room 11 Roof lift motor room 2 Lobby Riser Tower
Feature Insulating board lining to door
Product Type Asbestos Insulating Board
Extent Amount 4 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 32 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Presumed
Notes
Building Copperas Hill
Floor Level External
Area / Room 12 Roof lift motor room 2 upper level tank room
Feature Presumed asbestos in live electrics
Product Type Asbestos Textiles/Paper
Extent Amount 1 no.
Recommendation Inspect Prior to Disturbance
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 33 Reference Number: As Sample AR000253
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level External
Area / Room 12 Roof lift motor room 2 upper level tank room
Feature Mastic to wall joints
Product Type Reinforced Composite
Extent Amount 20 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 34 Reference Number: AR000254
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level External
Area / Room 13 Roof ventilation plant room 2
Feature Mastic to ventilation duct jointing
Product Type Reinforced Composite
Extent Amount < 100 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 2 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 35 Reference Number: AR000255
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level External
Area / Room 13 Roof ventilation plant room 2
Feature Bitumen above strammit ceiling
Product Type Well Bound Material
Extent Amount 500 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 2 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 36 Reference Number: AR000256
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level External
Area / Room 13 Roof ventilation plant room 2
Feature Loose gaskets
Product Type Asbestos Textiles/Paper
Extent Amount 3 no.
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 3 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 37 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Presumed
Notes
Building Copperas Hill
Floor Level External
Area / Room 13 Roof ventilation plant room 2
Feature Presumed asbestos in live electrics
Product Type Asbestos Textiles/Paper
Extent Amount 1 no.
Recommendation Inspect Prior to Disturbance
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 38 Reference Number: AR000257
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level External
Area / Room 13 Roof ventilation plant room 2
Feature Insulating board lining to walls
Product Type Asbestos Insulating Board
Extent Amount 360 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 39 Reference Number: As Sample AR000254
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level External
Area / Room 14 Roof ventilation plant room 1
Feature Mastic to ventilation duct jointing
Product Type Reinforced Composite
Extent Amount < 100 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 2 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 40 Reference Number: As Sample AR000255
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level External
Area / Room 14 Roof ventilation plant room 1
Feature Bitumen above strammit ceiling
Product Type Well Bound Material
Extent Amount 500 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 2 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 41 Reference Number: AR000258
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level External
Area / Room 14 Roof ventilation plant room 1
Feature Gaskets to pipework
Product Type Asbestos Textiles/Paper
Extent Amount 2 no.
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 3 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 42 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Presumed
Notes
Building Copperas Hill
Floor Level External
Area / Room 14 Roof ventilation plant room 1
Feature Presumed asbestos in live electrics
Product Type Asbestos Textiles/Paper
Extent Amount 1 no.
Recommendation Inspect Prior to Disturbance
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 43 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level External
Area / Room 14 Roof ventilation plant room 1
Feature Insulating board lining to walls
Product Type Asbestos Insulating Board
Extent Amount 360 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 44 Reference Number: AR000259
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level External
Area / Room 14 Roof ventilation plant room 1
Feature Insulating board debris to floor
Product Type Asbestos Insulating Board
Extent Amount 1 m
Recommendation Restrict access and remove
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage High damage - or delamination of materials, sprays and thermal insulation. Visible asbestos debris
3
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Chrysotile + Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 9 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 45 Reference Number: AR000260
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level External
Area / Room 14 Roof ventilation plant room 1
Feature Rope debris to ventilation ducting
Product Type Textiles/Paper
Extent Amount < 1 m
Recommendation
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
0
Extent of Damage High damage - or delamination of materials, sprays and thermal insulation. Visible asbestos debris
0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 46 Reference Number: AR000261
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level External
Area / Room 15 Roof
Feature White promenade tile and associated debris
Product Type Cement
Extent Amount 30 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage High damage - or delamination of materials, sprays and thermal insulation. Visible asbestos debris
0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 47 Reference Number: AR000262
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level External
Area / Room 15 Roof
Feature Dark promenade tiles and associated debris
Product Type Cement
Extent Amount 100 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage High damage - or delamination of materials, sprays and thermal insulation. Visible asbestos debris
0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 48 Reference Number: AR000263
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 1 Lift lobby
Feature Putty to timber beading on doors
Product Type Well Bound Material
Extent Amount 20 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 49 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 1 Lift lobby
Feature Insulating board behind external metal panels
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 50 Reference Number: As Sample AR000253
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 2 Lift lobby spiral staircase
Feature Mastic to wall joints
Product Type Reinforced Composite
Extent Amount 8 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 51 Reference Number: AR000265
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 2 Lift lobby spiral staircase
Feature Insulating board lining to door
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 6 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 52 Reference Number: As Sample AR000265
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 3 Lift lobby riser
Feature Insulating board lining to door
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 6 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 53 Reference Number: AR000266
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes This material is sporadic & intermittent throughout the floor. This material should be presumed present to all floors.
Building Copperas Hill
Floor Level 5th Floor
Area / Room 3 Lift lobby riser
Feature Mastic to wall joints
Product Type Well Bound Material
Extent Amount >250 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 2 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 54 Reference Number: AR000267
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 5 Room 30 Lockers
Feature Insulating board and associated debris in ceiling void
Product Type Asbestos Insulating Board
Extent Amount 12 m
Recommendation Restrict access and remove
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage High damage - or delamination of materials, sprays and thermal insulation. Visible asbestos debris
3
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 8 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 55 Reference Number: As Sample AR000253
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 6 Riser tower upper and lower level
Feature Mastic to wall joints
Product Type Reinforced Composite
Extent Amount 12 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 56 Reference Number: AR000268
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 6 Riser tower upper and lower level
Feature Coating to 3MF insulation in wall cavity
Product Type Textured Coating
Extent Amount 2 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Medium damage - significant breakage of materials or several small areas where material has been damaged revealing loose asbestos fibres
0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 57 Reference Number: AR000269
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 7 Corridor
Feature Panels above windows
Product Type Insulating Board
Extent Amount 12 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 58 Reference Number: AR000270
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 7 Corridor
Feature Mastic to ventilation duct joints
Product Type Well Bound Material
Extent Amount 100 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 2 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 59 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Presumed
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 7 Corridor
Feature Presumed gaskets to pipe work in ceiling void
Product Type Well-bound Material
Extent Amount < 100
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 2 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 60 Reference Number: AR000271
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 7 Corridor
Feature Rope gaskets to pipe hangers in ceiling void
Product Type Asbestos Textiles/Paper
Extent Amount < 100
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 61 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 9 Room 34a
Feature Insulating board panels behind external metal infills.
Product Type Asbestos Insulating Board
Extent Amount 12 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 62 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 12 Room 38 Training
Feature Insulating board behind external metal panels
Product Type Asbestos Insulating Board
Extent Amount 20 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 63 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 13 Room 39
Feature Insulating board behind external metal panels
Product Type Asbestos Insulating Board
Extent Amount 6 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 64 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 14 Rooms 40 and 41
Feature Insulating board behind external metal panels
Product Type Asbestos Insulating Board
Extent Amount 12 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 65 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 15 Room 42
Feature Insulating board behind external metal panels
Product Type Asbestos Insulating Board
Extent Amount 6 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 66 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 18 Room 48
Feature Insulating board behind external metal panels
Product Type Asbestos Insulating Board
Extent Amount 4 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 67 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 22 Room 46 Office
Feature Insulating board behind external metal panels
Product Type Asbestos Insulating Board
Extent Amount 4 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 68 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 23 Room 45 Resource Section
Feature Insulating board behind external metal panels
Product Type Asbestos Insulating Board
Extent Amount 20 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 69 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 24 Revenue Management
Feature Insulating board behind external metal panels
Product Type Asbestos Insulating Board
Extent Amount 12 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 70 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 25 Room 35 Classroom 3
Feature Insulating board behind external metal panels
Product Type Asbestos Insulating Board
Extent Amount 10 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 71 Reference Number: AR000272
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 26 Male toilet riser
Feature Insulating board lining to door
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 6 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 72 Reference Number: AR000273
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 26 Male toilet riser
Feature Loose gaskets
Product Type Asbestos Textiles/Paper
Extent Amount 3 no.
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 73 Reference Number: As Sample AR000267
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 27 Male toilets
Feature Insulating board shuttering in ceiling void
Product Type Asbestos Insulating Board
Extent Amount 4 m
Recommendation Restrict access and remove
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage High damage - or delamination of materials, sprays and thermal insulation. Visible asbestos debris
3
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 8 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 74 Reference Number: AR000274
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 27 Male toilets
Feature Bitumen around pipe penetration in ceiling void
Product Type Well Bound Material
Extent Amount < 1 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 75 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 27 Male toilets
Feature Insulating board behind external metal panels
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 76 Reference Number: AR000275
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 33 Room 14
Feature Insulating board ceiling and associated debris in ceiling void
Product Type Asbestos Insulating Board
Extent Amount 25 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 77 Reference Number: AR000276
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 38 Room 90
Feature Insulating board partition in ceiling void
Product Type Asbestos Insulating Board
Extent Amount 5 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 78 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 42 Room 59
Feature Insulating board behind external metal panels
Product Type Asbestos Insulating Board
Extent Amount 6 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 79 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 43 Rooms 58 and 57
Feature Insulating board behind external metal panels
Product Type Asbestos Insulating Board
Extent Amount 10 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 80 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 44 Rooms 56
Feature Insulating board behind external metal panels
Product Type Asbestos Insulating Board
Extent Amount 6 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 81 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 45 Rooms 55
Feature Insulating board behind external metal panels
Product Type Asbestos Insulating Board
Extent Amount 6 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 82 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 46 Room 54
Feature Insulating board behind external metal panels
Product Type Asbestos Insulating Board
Extent Amount 6 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 83 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 47 Room 53
Feature Insulating board behind external metal panels
Product Type Asbestos Insulating Board
Extent Amount 6 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 84 Reference Number: AR000277
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 52 Room 71 Store
Feature Mastic to door beading
Product Type Reinforced Composite
Extent Amount 4 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 85 Reference Number: AR000278
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 53 Room 73 Secure area
Feature Insulating board lining to door
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 6 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 86 Reference Number: AR000279
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 53 Room 73 Secure area
Feature Rope to pipe hanger in ceiling void
Product Type Asbestos Textiles/Paper
Extent Amount > 10 no.
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 87 Reference Number: AR000280
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 53 Room 73 Secure area
Feature Resin to counters
Product Type Reinforced Composite
Extent Amount < 2 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 88 Reference Number: AR000281
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 55 Rooms 60 - 62
Feature Room 62 Green vinyl under carpet
Product Type Reinforced Composite
Extent Amount 30 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 89 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 55 Rooms 60 - 62
Feature Insulating board behind external metal panels
Product Type Asbestos Insulating Board
Extent Amount 60 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 90 Reference Number: As Sample AR000281
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 56 Room 63
Feature Green vinyl to floor
Product Type Reinforced Composite
Extent Amount 40 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 91 Reference Number: AR000282
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 57 Rooms 65
Feature Red vinyl under carpet
Product Type Reinforced Composite
Extent Amount 100 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 92 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 57 Rooms 65
Feature Insulating board behind external metal panels
Product Type Asbestos Insulating Board
Extent Amount 40 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 93 Reference Number: As Sample AR000282
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 58 Room 64
Feature Red vinyl to floor
Product Type Reinforced Composite
Extent Amount 6 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 94 Reference Number: AR000283
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 59 Room 66
Feature Blue vinyl to floor
Product Type Reinforced Composite
Extent Amount 12 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 95 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 59 Room 66
Feature Insulating board behind external metal panels
Product Type Asbestos Insulating Board
Extent Amount 12 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 96 Reference Number: AR000284
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 60 Room 85 Syphon
Feature Textured coating to ceiling
Product Type Textured Coating
Extent Amount 10 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 97 Reference Number: As Sample AR000284
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 61 Room 67
Feature Textured coating to ceiling
Product Type Textured Coating
Extent Amount 8 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 98 Reference Number: As Sample AR000280
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 62 Room 68
Feature Resin to counter
Product Type Reinforced Composite
Extent Amount < 2 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 99 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 62 Room 68
Feature Insulating boards behind external metal panels
Product Type Asbestos Insulating Board
Extent Amount 80 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 100 Reference Number: AR000285
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 63 Room 95 Kitchen
Feature Insulating board to ceiling
Product Type Insulating Board
Extent Amount 12 m
Recommendation
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
0
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 101 Reference Number: As Sample AR000276
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 69 Room 27
Feature Insulating board partition in ceiling void
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 102 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 74 Corridor outside Room 23
Feature Loose insulating board on top of ducting in ceiling void
Product Type Asbestos Insulating Board
Extent Amount < 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 103 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 74 Corridor outside Room 23
Feature Insulating board behind external metal panels
Product Type Asbestos Insulating Board
Extent Amount 6 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 104 Reference Number: As Sample AR000267
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 75 Shop
Feature Insulating board shuttering in ceiling void
Product Type Asbestos Insulating Board
Extent Amount < 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage High damage - or delamination of materials, sprays and thermal insulation. Visible asbestos debris
3
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 8 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 105 Reference Number: AR000286
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 75 Shop
Feature Sink pad
Product Type Well Bound Material
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 3 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 106 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 75 Shop
Feature Insulating board behind external metal panels
Product Type Asbestos Insulating Board
Extent Amount 6 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 107 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Strongly Presumed
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 78 Room 22 Female WC
Feature Cement pipe in riser
Product Type Asbestos Cement
Extent Amount 3 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Crocidolite (or unknown) 3
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 108 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 79 Room 4 Dining room/servery
Feature Insulating board behind external metal panels
Product Type Asbestos Insulating Board
Extent Amount 120 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 109 Reference Number: AR000287
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 79 Room 4 Dining room/servery
Feature Insulating board lining to door
Product Type Insulating Board
Extent Amount 2 m
Recommendation
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 110 Reference Number: AR000288
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 79 Room 4 Dining room/servery
Feature Beading to door
Product Type Insulating Board
Extent Amount 4 m
Recommendation
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 111 Reference Number: As Sample AR000276
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 79 Room 4 Dining room/servery
Feature IB cladding to steelwork in ceiling void
Product Type Asbestos Insulating Board
Extent Amount 3 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 112 Reference Number: As Sample AR000276
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 82 Room 18 Kitchen
Feature IB cladding to steelwork in ceiling void and debris.
Product Type Asbestos Insulating Board
Extent Amount 3 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Medium damage - significant breakage of materials or several small areas where material has been damaged revealing loose asbestos fibres
2
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 8 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 113 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 4th Floor Mezzanine Floor
Area / Room 1 Main lobby
Feature AIB and metal infill above windows
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 114 Reference Number: AR000289
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 4th Floor Mezzanine Floor
Area / Room 2 Main riser
Feature Insulating board lining to door
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 115 Reference Number: AR000290
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 4th Floor Mezzanine Floor
Area / Room 2 Main riser
Feature Mastic to wall joints (both rooms)
Product Type Reinforced Composite
Extent Amount 6 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 2 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 116 Reference Number: As Sample AR000267
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 4th Floor Mezzanine Floor
Area / Room 3 Old server room
Feature Insulating board shuttering in ceiling void
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Restrict access and remove
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage High damage - or delamination of materials, sprays and thermal insulation. Visible asbestos debris
3
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 8 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 117 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 4th Floor
Area / Room 1 Room 25 Lift Lobby
Feature IB infill behind concrete to windows
Product Type Asbestos Insulating Board
Extent Amount 4 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 6 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 118 Reference Number: As Sample AR000267
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 4th Floor
Area / Room 2 Rooms 23 and 24 Toilets
Feature Insulating board shuttering and infills in ceiling void
Product Type Asbestos Insulating Board
Extent Amount 4 m
Recommendation Restrict access and remove
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage High damage - or delamination of materials, sprays and thermal insulation. Visible asbestos debris
3
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 8 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 119 Reference Number: AR000291
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 4th Floor
Area / Room 3 Room 20 Riser Tower
Feature Durasteel cladding to wall (high and low level)
Product Type Asbestos Insulating Board
Extent Amount 15 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile + Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 120 Reference Number: AR000292
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 4th Floor
Area / Room 4 Lift lobby riser
Feature Insulating board lining to door
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 121 Reference Number: As Sample AR000291
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 4th Floor
Area / Room 5 Room 19 OCR Training
Feature Durasteel cladding to wall
Product Type Asbestos Insulating Board
Extent Amount 3 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile + Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 122 Reference Number: As Sample AR000249
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 4th Floor
Area / Room 8 Above Room 19
Feature Durasteel partition behind plasterboard
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 123 Reference Number: AR000293
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 4th Floor Mezzanine Floor
Area / Room 7 Mezzanine offices North
Feature Vinyl floor tiles beneath carpet
Product Type Reinforced Composite
Extent Amount 125 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 124 Reference Number: AR000294
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 4th Floor
Area / Room 16 Rooms 26-30
Feature Mastic to wall expansion joints
Product Type Well Bound Material
Extent Amount > 25 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 125 Reference Number: AR000295
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 4th Floor
Area / Room 17 Room 23-24 Toilet Riser
Feature Insulating board lining to door
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 126 Reference Number: As Sample AR000249
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 4th Floor
Area / Room 18 Room 36 Chain enclosure
Feature Durasteel lining to sack conveyor
Product Type Asbestos Insulating Board
Extent Amount 36 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 127 Reference Number: As Sample AR000265
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 4th Floor
Area / Room 21 Room 41 Lift Lobby
Feature IB lining to double doors to room 56
Product Type Asbestos Insulating Board
Extent Amount 4 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 128 Reference Number: As Sample AR000292
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 4th Floor
Area / Room 22 Riser adjacent room 41
Feature Insulating board lining to door
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 129 Reference Number: As Sample AR000292
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 4th Floor
Area / Room 23 Riser adjacent room 55
Feature Insulating board lining to door
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 130 Reference Number: AR000296
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 4th Floor
Area / Room 25 Room 54 Male WC
Feature Resin WC cisterns
Product Type Reinforced Composite
Extent Amount 2 no.
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Medium damage - significant breakage of materials or several small areas where material has been damaged revealing loose asbestos fibres
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 131 Reference Number: As Sample AR000246
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 4th Floor
Area / Room 25 Room 54 Male WC
Feature Cement flue pipe
Product Type Asbestos Cement
Extent Amount 3 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 3 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 132 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Presumed
Notes
Building Copperas Hill
Floor Level 4th Floor
Area / Room 26 South West Lift Lobby
Feature Recessed gasket to flange on fire hydrant pipework.
Product Type Asbestos Textiles/Paper
Extent Amount 1 no.
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 133 Reference Number: As Sample AR000296
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 4th Floor
Area / Room 27 Room 48 Male WC
Feature Resin WC cisterns
Product Type Reinforced Composite
Extent Amount 1 no.
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Medium damage - significant breakage of materials or several small areas where material has been damaged revealing loose asbestos fibres
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 134 Reference Number: As Sample AR000246
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 4th Floor
Area / Room 27 Room 48 Male WC
Feature Cement flue pipe
Product Type Asbestos Cement
Extent Amount 3 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 3 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 135 Reference Number: As Sample AR000265
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 4th Floor
Area / Room 30 West Stair Lobby
Feature IB lining to double doors to stairwell
Product Type Asbestos Insulating Board
Extent Amount 4 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 136 Reference Number: As Sample AR000299
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 4th Floor
Area / Room 33 Room 56, main floor area
Feature AIB cladding to lift motor room above lift LSG001 including AIB fillets to underlying timber studs and noggins.
Product Type Asbestos Insulating Board
Extent Amount 64 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 6 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 137 Reference Number: As Sample AR000275
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 4th Floor
Area / Room 33 Room 56, main floor area
Feature AIB infill to ceiling expansion joints x2
Product Type Asbestos Insulating Board
Extent Amount 100 lm
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 138 Reference Number: As Sample AR000249
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 4th Floor
Area / Room 33 Room 56, main floor area
Feature Durasteel fire hatch to chute adjacent to slide 1
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 139 Reference Number: As Sample AR000249
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 4th Floor
Area / Room 33 Room 56, main floor area
Feature Durasteel fire hatches to T, U and S chutes
Product Type Asbestos Insulating Board
Extent Amount 6 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 140 Reference Number: AR000346
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 4th Floor
Area / Room 33 Room 56, main floor area
Feature Rubber beading to curtain wall at high level
Product Type Well Bound Material
Extent Amount 50
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 141 Reference Number: As Sample AR000299
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 4th Floor
Area / Room 34 Lift Moor Room for LSG001
Feature AIB wall cladding on AIB fillets on timber studs and noggins.
Product Type Asbestos Insulating Board
Extent Amount 48 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Medium damage - significant breakage of materials or several small areas where material has been damaged revealing loose asbestos fibres
2
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 8 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 142 Reference Number: AR000297
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 4th Floor
Area / Room 34 Lift Moor Room for LSG001
Feature Cement brake shoes to lift motor
Product Type Reinforced Composite
Extent Amount 2 no.
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 143 Reference Number: AR000309
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 3rd Floor Mezzanine Floor
Area / Room 1 North Lift Lobby
Feature IB lining to double doors to stairwell.
Product Type Asbestos Insulating Board
Extent Amount 4 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 144 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor Mezzanine Floor
Area / Room 1 North Lift Lobby
Feature AIB window infills behind overspill concrete behind ceiling RSJ
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 145 Reference Number: As Sample AR000295
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor Mezzanine Floor
Area / Room 2 North Engineers Riser
Feature IB lining to door
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 146 Reference Number: As Sample AR000301
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor Mezzanine Floor
Area / Room 2 North Engineers Riser
Feature Bitumen acoustic pads within Water Bunnie
Product Type Well Bound Material
Extent Amount 1 no.
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 147 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor Mezzanine Floor
Area / Room 3 North Locker Room
Feature Insulation board infills above windows x 3
Product Type Asbestos Insulating Board
Extent Amount 3 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 148 Reference Number: AR000298
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 3rd Floor Mezzanine Floor
Area / Room 3 North Locker Room
Feature Putty seal to HVAC ducting in ceiling void
Product Type Well Bound Material
Extent Amount 6 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 2 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 149 Reference Number: As Sample AR000266
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor Mezzanine Floor
Area / Room 4 North Lockers Riser
Feature Brown mastic to walls
Product Type Well Bound Material
Extent Amount 12 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 2 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 150 Reference Number: AR000299
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 3rd Floor Mezzanine Floor
Area / Room 5 Conveyor gallery
Feature AIB wall panels
Product Type Asbestos Insulating Board
Extent Amount 400 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 6 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 151 Reference Number: As Sample AR000297
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor Mezzanine Floor
Area / Room 5 Conveyor gallery
Feature Redundant motor brake shoes
Product Type Reinforced Composite
Extent Amount 2 no.
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 152 Reference Number: AR000300
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 3rd Floor Mezzanine Floor
Area / Room 5 Conveyor gallery
Feature Grey vinyl floor tiles
Product Type Reinforced Composite
Extent Amount 250 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 153 Reference Number: As Sample AR000291
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor Mezzanine Floor
Area / Room 5 Conveyor gallery
Feature Durasteel airlock to chain exit
Product Type Asbestos Insulating Board
Extent Amount 10 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile + Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 154 Reference Number: As Sample AR000249
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor Mezzanine Floor
Area / Room 5 Conveyor gallery
Feature Durasteel floor hatches
Product Type Asbestos Insulating Board
Extent Amount 3 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 155 Reference Number: As Sample AR000291
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor Mezzanine Floor
Area / Room 5 Conveyor gallery
Feature Durasteel boxing to conveyor feed from loading bay
Product Type Asbestos Insulating Board
Extent Amount 14 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile + Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 156 Reference Number: As Sample AR000246
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor Mezzanine Floor
Area / Room 8 South East Male WC
Feature Cement flue in riser
Product Type Asbestos Cement
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 3 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 157 Reference Number: AR000301
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 3rd Floor Mezzanine Floor
Area / Room 9 South East Female WC
Feature Bitumen acoustic pads in Water Bunnies x2
Product Type Well Bound Material
Extent Amount 1 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 158 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Presumed
Notes Presumed present all floors
Building Copperas Hill
Floor Level 3rd Floor Mezzanine Floor
Area / Room 12 South West Lobby
Feature Gasket to fire riser
Product Type Asbestos Textiles/Paper
Extent Amount 5 no.
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 159 Reference Number: AR000302
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 1 Room 34 Entrance lobby/Reception
Feature Insulating board infills above windows
Product Type Insulating Board
Extent Amount 8 m
Recommendation
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
0
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 160 Reference Number: AR000303
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 1 Room 34 Entrance lobby/Reception
Feature Textured coating to ceiling and above lift doors
Product Type Textured Coating
Extent Amount 35 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 161 Reference Number: AR000304
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 1 Room 34 Entrance lobby/Reception
Feature Supalux boarding to ceiling and in ceiling void
Product Type Insulating Board
Extent Amount 30 m
Recommendation
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
0
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 162 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Presumed
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 1 Room 34 Entrance lobby/Reception
Feature Mastic to ventilation ducting in ceiling void
Product Type Reinforced Composite
Extent Amount < 40 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 2 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 163 Reference Number: As Sample AR000295
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 2 Room 37
Feature Insulating boarding to door lining
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 164 Reference Number: AR000305
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 3 Room 38 Loading Bays
Feature IB cladding/fascia above loading bay doors
Product Type Insulating Board
Extent Amount 50 m
Recommendation
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
0
Extent of Damage High damage - or delamination of materials, sprays and thermal insulation. Visible asbestos debris
0
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 165 Reference Number: AR000306
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 3 Room 38 Loading Bays
Feature IB infill to ceiling expansion joint and debris to conduit
Product Type Asbestos Insulating Board
Extent Amount 50 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Medium damage - significant breakage of materials or several small areas where material has been damaged revealing loose asbestos fibres
2
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 8 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 166 Reference Number: AR000307
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 3 Room 38 Loading Bays
Feature Vicuclad beam cladding
Product Type Insulating Board
Extent Amount > 1000 m
Recommendation
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
0
Extent of Damage Medium damage - significant breakage of materials or several small areas where material has been damaged revealing loose asbestos fibres
0
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 167 Reference Number: AR000308
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 3 Room 38 Loading Bays
Feature T/C to beam cladding
Product Type Textured Coating
Extent Amount > 1000 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 168 Reference Number: As Sample AR000299
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 3 Room 38 Loading Bays
Feature IB wall cladding and fillets above G6 goods lift
Product Type Asbestos Insulating Board
Extent Amount 150 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 169 Reference Number: AR000312
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 3 Room 38 Loading Bays
Feature Insulating board shuttering to ventilation duct
Product Type Asbestos Insulating Board
Extent Amount 250 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 6 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 170 Reference Number: As Sample AR000299
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 3 Room 38 Loading Bays
Feature IB wall cladding and fillets above Eastern loading bay platforms & stores
Product Type Asbestos Insulating Board
Extent Amount 300 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 6 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 171 Reference Number: As Sample AR000291
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 3 Room 38 Loading Bays
Feature Durasteel to chain enclosure
Product Type Asbestos Insulating Board
Extent Amount 50 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile + Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 172 Reference Number: As Sample AR000294
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 3 Room 38 Loading Bays
Feature Mastic to wall expansion joints
Product Type Well Bound Material
Extent Amount 10 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 173 Reference Number: AR000310
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 3 Room 38 Loading Bays
Feature Mastic to ventilation duct jointing
Product Type Reinforced Composite
Extent Amount 150 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 2 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 174 Reference Number: As Sample AR000291
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 3 Room 38 Loading Bays
Feature Durasteel cladding to wall
Product Type Asbestos Insulating Board
Extent Amount 5 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile + Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 175 Reference Number: As Sample AR000291
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 3 Room 38 Loading Bays
Feature Durasteel cladding (high and low level)
Product Type Asbestos Insulating Board
Extent Amount 20 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile + Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 176 Reference Number: As Sample AR000289
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 6 Room 36 Riser
Feature Insulating board lining to door
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 177 Reference Number: As Sample AR000289
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 13 Room 33
Feature Insulating board lining to door
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 178 Reference Number: AR000313
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 13 Room 43 Lobby
Feature Insulating board lining to door
Product Type Asbestos Insulating Board
Extent Amount 4 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 179 Reference Number: AR000314
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 18 Room 55
Feature Vinyl floor tiles
Product Type Reinforced Composite
Extent Amount 15 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 180 Reference Number: AR000315
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 20 Room 21 Safe
Feature Textured coating to walls and ceiling
Product Type Textured Coating
Extent Amount 24 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 181 Reference Number: As Sample AR000294
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 21 Room 22
Feature Mastic to wall joints
Product Type Well Bound Material
Extent Amount 4 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 182 Reference Number: As Sample AR000294
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 22 Room 23
Feature Mastic to wall joints
Product Type Well Bound Material
Extent Amount 8 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 183 Reference Number: AR000316
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 24 Rooms 12 and 9
Feature Floor tiles
Product Type Reinforced Composite
Extent Amount 200 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 184 Reference Number: AR000317
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 25 Rooms 6, 45, 46 Priority services and offices
Feature Floor tiles
Product Type Reinforced Composite
Extent Amount 170 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 185 Reference Number: As Sample AR000315
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 28 Room 28 Strong room
Feature Textured coating to walls and ceiling
Product Type Textured Coating
Extent Amount 65 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 186 Reference Number: As Sample AR000313
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 32 Rooms 1, 3, 4, 5
Feature Insulating board lining to room 3 stairwell door
Product Type Asbestos Insulating Board
Extent Amount 4 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 187 Reference Number: As Sample AR000312
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room 15 Room 24 Sorting area
Feature Mastic to ventilation duct joints
Product Type Asbestos Insulating Board
Extent Amount > 100 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 6 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 188 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Presumed
Notes
Building Copperas Hill
Floor Level 3rd Floor Mezzanine Floor
Area / Room 16 Throughout level 3 Mezz
Feature Presumed asbestos in live electrics
Product Type Asbestos Textiles/Paper
Extent Amount < 100 no.
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 189 Reference Number: AR000318
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 3rd Floor Mezzanine Floor
Area / Room 34 Room 18 Mezz plant room
Feature Mastic to ventilation duct jointing
Product Type Reinforced Composite
Extent Amount < 50 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 2 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 190 Reference Number: AR000319
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 3rd Floor Mezzanine Floor
Area / Room 17 Room 17 above G6 lift
Feature Floor tiles
Product Type Reinforced Composite
Extent Amount 150 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 3 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 191 Reference Number: As Sample AR000299
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor Mezzanine Floor
Area / Room 17 Room 17 above G6 lift
Feature Insulating board to walls
Product Type Asbestos Insulating Board
Extent Amount 100 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 6 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 192 Reference Number: AR000320
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 1 Room 29 Boiler Room
Feature Insulating board shuttering to foul chamber
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Chrysotile + Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 193 Reference Number: AR000321
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 1 Room 29 Boiler Room
Feature Dust/debris to floor channel
Product Type Dust/Debris
Extent Amount 10 m
Recommendation Remove if likely to be disturbed
Product Score High Fibre Release - Thermal insulation (e.g. pipe and boiler lagging) sprayed asbestos, loose asbestos, asbestos mattresses and packing
3
Extent of Damage High damage - or delamination of materials, sprays and thermal insulation. Visible asbestos debris
3
Surface Treatment Unsealed lagging and sprays 3
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 11 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 194 Reference Number: AR000322
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 1 Room 29 Boiler Room
Feature Dust/debris in floor channel
Product Type Dust/Debris
Extent Amount 10 m
Recommendation
Product Score High Fibre Release - Thermal insulation (e.g. pipe and boiler lagging) sprayed asbestos, loose asbestos, asbestos mattresses and packing
0
Extent of Damage High damage - or delamination of materials, sprays and thermal insulation. Visible asbestos debris
0
Surface Treatment Unsealed lagging and sprays 0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 195 Reference Number: AR000323
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 1 Room 29 Boiler Room
Feature Rope gasket to boiler
Product Type Asbestos Textiles/Paper
Extent Amount 1 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 196 Reference Number: AR000324
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 1 Room 29 Boiler Room
Feature Rope gasket to boiler
Product Type Asbestos Textiles/Paper
Extent Amount 1 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 197 Reference Number: AR000325
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 1 Room 29 Boiler Room
Feature Rope gasket to boiler
Product Type Asbestos Textiles/Paper
Extent Amount 1 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 198 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Presumed
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 1 Room 29 Boiler Room
Feature Presumed asbestos within electrics
Product Type Asbestos Textiles/Paper
Extent Amount < 10 no.
Recommendation Inspect Prior to Disturbance
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 199 Reference Number: As Sample AR000324
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 1 Room 29 Boiler Room
Feature Gasket to front of boilers
Product Type Asbestos Textiles/Paper
Extent Amount 1 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 200 Reference Number: AR000326
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 1 Room 29 Boiler Room
Feature Loose gasket
Product Type Textiles/Paper
Extent Amount < 2 m
Recommendation
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
0
Extent of Damage High damage - or delamination of materials, sprays and thermal insulation. Visible asbestos debris
0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 201 Reference Number: AR000327
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 1 Room 29 Boiler Room
Feature Gaskets to pipe work throughout
Product Type Textiles/Paper
Extent Amount < 100 m
Recommendation
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 202 Reference Number: AR000328
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 1 Room 29 Boiler Room
Feature Residue to pipe work
Product Type Dust/Debris
Extent Amount 10 m
Recommendation
Product Score High Fibre Release - Thermal insulation (e.g. pipe and boiler lagging) sprayed asbestos, loose asbestos, asbestos mattresses and packing
0
Extent of Damage High damage - or delamination of materials, sprays and thermal insulation. Visible asbestos debris
0
Surface Treatment Unsealed lagging and sprays 0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 203 Reference Number: AR000329
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 1 Room 29 Boiler Room
Feature Mastic to vent duct joints
Product Type Reinforced Composite
Extent Amount 10 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 2 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 204 Reference Number: As Sample AR000294
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 1 Room 29 Boiler Room
Feature Mastic to wall joints
Product Type Well Bound Material
Extent Amount 10
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 205 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Presumed
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 1 Room 29 Boiler Room
Feature No access within plant
Product Type Asbestos Textiles/Paper
Extent Amount 300 m
Recommendation Inspect Prior to Disturbance
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 206 Reference Number: As Sample AR000327
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 2 Room 28 Tank Room
Feature Gaskets to pipework
Product Type Textiles/Paper
Extent Amount < 10 no.
Recommendation
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 207 Reference Number: As Sample AR000294
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 2 Room 28 Tank Room
Feature Mastic to wall joints
Product Type Well Bound Material
Extent Amount 10 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 208 Reference Number: As Sample AR000309
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 3 Lift lobby x2 S/W Tower
Feature IB door lining
Product Type Asbestos Insulating Board
Extent Amount 4 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 209 Reference Number: AR000331
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 3 Lift lobby x2 S/W Tower
Feature Mastic to window glazing of double fire doors
Product Type Well Bound Material
Extent Amount 1 lm
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 210 Reference Number: As Sample AR000304
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 5 Store S/W Tower
Feature Supalux board to ventilation surround
Product Type Insulating Board
Extent Amount 3 m
Recommendation
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 211 Reference Number: As Sample AR000294
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 6 Main Corridor
Feature Mastic to wall expansion joints
Product Type Well Bound Material
Extent Amount > 20 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 212 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Presumed
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 6 Main Corridor
Feature Gaskets to pipework
Product Type Asbestos Textiles/Paper
Extent Amount Numerous
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 213 Reference Number: As Sample AR000294
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 7 Rooms 19-23
Feature Mastic to wall expansion joints
Product Type Well Bound Material
Extent Amount > 25 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 214 Reference Number: As Sample AR000329
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 7 Rooms 19-23
Feature Mastic to ventilation duct flange
Product Type Reinforced Composite
Extent Amount 1 lm
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 2 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 215 Reference Number: AR000332
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 7 Rooms 19-23
Feature IB noticeboard
Product Type Insulating Board
Extent Amount 1 m
Recommendation
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
0
Extent of Damage Medium damage - significant breakage of materials or several small areas where material has been damaged revealing loose asbestos fibres
0
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 216 Reference Number: As Sample AR000294
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 8 Rooms 17 and 18
Feature Mastic to wall expansion joint
Product Type Well Bound Material
Extent Amount 5 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 217 Reference Number: As Sample AR000313
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 8 Rooms 17 and 18
Feature IB door lining to chute riser
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 218 Reference Number: As Sample AR000294
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 9 Rooms 2a,b and c (West)
Feature Mastic to wall expansion joints
Product Type Well Bound Material
Extent Amount > 5 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 219 Reference Number: As Sample AR000313
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 10 Room 2 Cleaners (West)
Feature IB door lining
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 220 Reference Number: As Sample AR000309
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 11 Lift lobby West Tower
Feature IB door lining
Product Type Asbestos Insulating Board
Extent Amount 4 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 221 Reference Number: AR000333
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 12 Room 1 Union Room
Feature DPC to window void
Product Type Well Bound Material
Extent Amount > 1 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 222 Reference Number: AR000334
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 15 Room 6 Addressograph Store
Feature Vinyl floor tiles and bitumen adhesive below
Product Type Reinforced Composite
Extent Amount 15 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 3 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 223 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Strongly Presumed
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 15 Room 6 Addressograph Store
Feature Lining to doors to stairs (visible)
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 224 Reference Number: As Sample AR000334
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 16 Rooms 7-9, 14-15 Classrooms 1 and 2 and adjacent
Feature Vinyl floor tiles and bitumen adhesive below
Product Type Reinforced Composite
Extent Amount 100 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 3 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 225 Reference Number: As Sample AR000334
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 17 Rooms 10 - 13 Callers Office and associated areas
Feature Vinyl floor tiles and bitumen adhesive below
Product Type Reinforced Composite
Extent Amount 15 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 3 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 226 Reference Number: AR000335
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level External
Area / Room 16 Entrance to Service Centre
Feature Board to canopy
Product Type Insulating Board
Extent Amount 3 m
Recommendation
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 227 Reference Number: As Sample AR000294
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 18 Room 35 - 36
Feature Mastic to wall expansion joint
Product Type Well Bound Material
Extent Amount > 5 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 228 Reference Number: As Sample AR000258
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 18 Room 35 - 36
Feature CAF gaskets to pipework and compressor pipes
Product Type Asbestos Textiles/Paper
Extent Amount 15 no.
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 3 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 229 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Presumed
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 18 Room 35 - 36
Feature Electrical switch boxes presumed as live
Product Type Asbestos Textiles/Paper
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 230 Reference Number: As Sample AR000254
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 19 Fume Extract and Plenum Chamber (accessed via 37)
Feature Mastic to ventilation duct flanges
Product Type Reinforced Composite
Extent Amount > 15 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 2 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 231 Reference Number: As Sample AR000266
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 19 Fume Extract and Plenum Chamber (accessed via 37)
Feature Mastic to wall expansion joint
Product Type Well Bound Material
Extent Amount 5 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 2 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 232 Reference Number: AR000336
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 19 Fume Extract and Plenum Chamber (accessed via 37)
Feature Vinyl expansion collars to vent ducting
Product Type Reinforced Composite
Extent Amount 4 no.
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 233 Reference Number: As Sample AR000312
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes Ducts service the 3rd floor loading bay vehicle exhaust extraction and run on 2x levels. The upper level services the central 50% of the loading bays and the lower level connects to the extremities of the loading bay.
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 19 Fume Extract and Plenum Chamber (accessed via 37)
Feature IB shuttering to duct ceiling
Product Type Asbestos Insulating Board
Extent Amount > 200 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 6 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 234 Reference Number: As Sample AR000306
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 20 Room 29a Engineers Workshop and 30 Electric
Feature IB panels to concrete upper expansion joint.
Product Type Asbestos Insulating Board
Extent Amount 14 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Medium damage - significant breakage of materials or several small areas where material has been damaged revealing loose asbestos fibres
2
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 8 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 235 Reference Number: As Sample AR000258
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 20 Room 29a Engineers Workshop and 30 Electric
Feature CAF gaskets to pipework
Product Type Asbestos Textiles/Paper
Extent Amount 15 no.
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 3 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 236 Reference Number: As Sample AR000266
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 20 Room 29a Engineers Workshop and 30 Electric
Feature Mastic to wall expansion joints
Product Type Well Bound Material
Extent Amount > 10 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 2 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 237 Reference Number: AR000337
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 20 Room 29a Engineers Workshop and 30 Electric
Feature DPC within floor service hatch
Product Type Well Bound Material
Extent Amount < 1 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 238 Reference Number: AR000338
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 20 Room 29a Engineers Workshop and 30 Electric
Feature Resin panel to electrical switch gear
Product Type Well Bound Material
Extent Amount 1 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 3 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 239 Reference Number: As Sample AR000254
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 20 Room 29a Engineers Workshop and 30 Electric
Feature Mastic to ventilation duct flanges
Product Type Reinforced Composite
Extent Amount 20 >
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Good condition - no visible damage 0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 2 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 240 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Presumed
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 21 Room 38 and 39
Feature Presumed CAF and rope gaskets machinery and pipework
Product Type Asbestos Textiles/Paper
Extent Amount 2 m
Recommendation Inspect Prior to Disturbance
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 241 Reference Number: AR000339
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 22 Room 24 - 27
Feature IB wall partions
Product Type Insulating Board
Extent Amount 30 m
Recommendation
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
0
Extent of Damage Medium damage - significant breakage of materials or several small areas where material has been damaged revealing loose asbestos fibres
0
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 242 Reference Number: As Sample AR000294
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 22 Room 24 - 27
Feature Mastic to wall expansion joint
Product Type Well Bound Material
Extent Amount 10 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 243 Reference Number: As Sample AR000320
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room 22 Room 24 - 27
Feature IB shuttering to foul drain
Product Type Asbestos Insulating Board
Extent Amount 1 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Chrysotile + Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 244 Reference Number: As Sample AR000335
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level External
Area / Room 17 Plant Room and Substation External Canopy
Feature IB ceiling panels and infills
Product Type Insulating Board
Extent Amount 6 m
Recommendation
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 245 Reference Number: AR000340
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level External
Area / Room 17 Plant Room and Substation External Canopy
Feature CAF gasket to pipework
Product Type Asbestos Textiles/Paper
Extent Amount 8 no.
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 246 Reference Number: As Sample AR000313
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 1st Floor
Area / Room 1 Room 12 Lift lobby
Feature IB door linings
Product Type Asbestos Insulating Board
Extent Amount 4 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 247 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 1st Floor
Area / Room 2 Room 11 and 13 Sensitive Waste
Feature IB infill above door and loose to floor and in ceiling void
Product Type Asbestos Insulating Board
Extent Amount 3 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Medium damage - significant breakage of materials or several small areas where material has been damaged revealing loose asbestos fibres
2
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 8 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 248 Reference Number: As Sample AR000272
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 1st Floor
Area / Room 2 Room 11 and 13 Sensitive Waste
Feature IB door lining
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 6 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 249 Reference Number: As Sample AR000294
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 1st Floor
Area / Room 3 Room 3 and 10
Feature Mastic to wall expansion joint
Product Type Well Bound Material
Extent Amount 5 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 250 Reference Number: As Sample AR000313
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 1st Floor
Area / Room 3 Room 3 and 10
Feature IB door lining
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 251 Reference Number: As Sample AR000294
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 1st Floor
Area / Room 4 Room 5 - 9
Feature Mastic to wall expansion joint
Product Type Well Bound Material
Extent Amount 5 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 252 Reference Number: As Sample AR000294
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 1st Floor
Area / Room 5 Room 4
Feature Mastic to wall expansion joint
Product Type Well Bound Material
Extent Amount 5 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 253 Reference Number: As Sample AR000309
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 1st Floor
Area / Room 5 Room 4
Feature IB door lining
Product Type Asbestos Insulating Board
Extent Amount 4 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 254 Reference Number: As Sample AR000313
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 1st Floor
Area / Room 6 West Tower Corridor
Feature IB door linings
Product Type Asbestos Insulating Board
Extent Amount 6 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Good condition - no visible damage 0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 255 Reference Number: AR000341
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level Lift Shaft
Area / Room 1 G4 (LPG 009)
Feature Textured coating to walls
Product Type Textured Coating
Extent Amount > 200 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 256 Reference Number: AR000342
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level Lift Shaft
Area / Room 2 G2 (LPG 007)
Feature Textured coating to walls
Product Type Textured Coating
Extent Amount > 250 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 257 Reference Number: AR000343
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level Lift Shaft
Area / Room 3 G1 (LPG 006)
Feature IB beam cladding
Product Type Insulating Board
Extent Amount > 100 lm
Recommendation
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 258 Reference Number: AR000344
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes Present between floors 3 to 5
Building Copperas Hill
Floor Level Lift Shaft
Area / Room 4 P1-3 Passenger Lift
Feature IB wall panels
Product Type Asbestos Insulating Board
Extent Amount > 150 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 259 Reference Number: AR000345
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes Present between floors 3 to 5
Building Copperas Hill
Floor Level Lift Shaft
Area / Room 4 P1-3 Passenger Lift
Feature Mastic to wall expansion joint
Product Type Well Bound Material
Extent Amount > 50 lm
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 3 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 260 Reference Number: AR000357
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
Asbestos Identified
Notes
Building Copperas Hill
Floor Level External
Area / Room 18 West Tower Loading bay (Level 1)
Feature Millboard canopy above loading bay doors
Product Type Asbestos Insulating Board
Extent Amount 6 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Medium damage - significant breakage of materials or several small areas where material has been damaged revealing loose asbestos fibres
2
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 261 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Presumed
No Photo Has Been Taken
Notes
Building Copperas Hill
Floor Level 1st Floor
Area / Room Throughout Level 1
Feature Presumed ACM's to live electrics
Product Type Asbestos Textiles/Paper
Extent Amount Throughout
Recommendation Inspect Prior to Disturbance
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 6 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 262 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Presumed
No Photo Has Been Taken
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room Throughout Level 2
Feature Presumed ACM's to live electrics
Product Type Asbestos Textiles/Paper
Extent Amount Throughout
Recommendation Inspect Prior to Disturbance
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 6 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 263 Reference Number: N/A
Inspection / Sample Visual Inspection Inspection Cross Reference / Visual I.D.
Asbestos Presumed
No Photo Has Been Taken
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room Throughout Level 3
Feature Presumed ACM's to live electrics
Product Type Asbestos Textiles/Paper
Extent Amount Throughout
Recommendation Inspect Prior to Disturbance
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 6 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 264 Reference Number: BS011674
Inspection / Sample Sample taken Inspection Cross Reference / Visual I.D.
N.A.D.I.S
Notes
Building Copperas Hill
Floor Level External
Area / Room Wash Cabin
Feature Felt to external roof
Product Type Well Bound Material
Extent Amount 7 m
Recommendation
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
0
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
0
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 265 Reference Number: As Sample AR000265
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 4th Floor Mezzanine Floor
Area / Room 4m West Tower 4mw1 - 4mw3
Feature IB door lining
Product Type Asbestos Insulating Board
Extent Amount 4 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 6 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 266 Reference Number: As Sample AR000246
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 4th Floor Mezzanine Floor
Area / Room 4m South West Tower 4msw1-4msw3
Feature Cement flue pipe in toilet riser
Product Type Asbestos Cement
Extent Amount 3 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 267 Reference Number: As Sample AR000265
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 4th Floor Mezzanine Floor
Area / Room 4m South West Tower 4msw1-4msw3
Feature IB door lining to stairwell
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 6 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 268 Reference Number: As Sample AR000265
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 4th Floor Mezzanine Floor
Area / Room 4m South East Tower 4mse1- 4mse 3a,b & c
Feature IB door lining to stairwell
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 6 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 269 Reference Number: As Sample AR000246
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 4th Floor Mezzanine Floor
Area / Room 4m South East Tower 4mse1- 4mse 3a,b & c
Feature Cement flue pipe in toilet riser
Product Type Asbestos Cement
Extent Amount 3 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 4 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 270 Reference Number: As Sample AR000249
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room Riser Tower Conveyor to Tunnel
Feature Durasteel wall infills
Product Type Asbestos Insulating Board
Extent Amount 4 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 6 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 271 Reference Number: As Sample AR000254
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room Riser Tower Conveyor to Tunnel
Feature Mastic to ventilation duct flange joints
Product Type Reinforced Composite
Extent Amount >5 m
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
1
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Reinforced plastics, resins, vinyl tiles, well bound materials, bitumen adhesives, damp proof course
0
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 3 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 272 Reference Number: As Sample AR000258
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room Riser Tower Conveyor to Tunnel
Feature CAF gaskets to pipework
Product Type Asbestos Textiles/Paper
Extent Amount <10 no.
Recommendation Remove if likely to be disturbed
Product Score Low Fibre Release - Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.)
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 273 Reference Number: As Sample AR000264
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor
Area / Room Riser Tower Conveyor to Tunnel
Feature IB lining to door
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 6 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 274 Reference Number: As Sample AR000246
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 3rd Floor
Area / Room Riser Tower Conveyor to Tunnel
Feature Durasteel panel within mail chute - No access to sample
Product Type Asbestos Cement
Extent Amount 1 m
Recommendation Inspect Prior to Disturbance
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
1
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Chrysotile 1
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 5 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 275 Reference Number: As Sample AR000276
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 51 Rooms 48, 49, 51, 52
Feature IB cladding above window in ceiling void (Room 48-49 Customer Services)
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 276 Reference Number: As Sample AR000276
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 5th Floor
Area / Room 81 Room 70 Non Smoking Lounge
Feature IB beam cladding in ceiling void above window (Room 70 & Room 5)
Product Type Asbestos Insulating Board
Extent Amount 2 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 7 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 277 Reference Number: As Sample AR000257
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level External
Area / Room External Window Infills (Behind Brown Panels)
Feature Ib window infill panels
Product Type Asbestos Insulating Board
Extent Amount >200 m
Recommendation Remove if likely to be disturbed
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage Low damage - a few scratches or surface marks; broken edges on boards, tiles etc.
1
Surface Treatment Enclosed sprays and lagging, Sealed AIB, asbestos cement, textured coating, gasket
1
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 6 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 278 Reference Number: As Sample BS021507
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor Mezzanine Floor
Area / Room 2M-003 Vehicle Exhaust Duct - North (Upper)
Feature Debris within lip of access hatch
Product Type Dust/Debris
Extent Amount 1 m
Recommendation
Product Score High Fibre Release - Thermal insulation (e.g. pipe and boiler lagging) sprayed asbestos, loose asbestos, asbestos mattresses and packing
0
Extent of Damage High damage - or delamination of materials, sprays and thermal insulation. Visible asbestos debris
0
Surface Treatment Unsealed lagging and sprays 0
Asbestos Type No Asbestos Detected 0
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score N/A Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 279 Reference Number: As Sample BS021508
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor Mezzanine Floor
Area / Room 2M-001 Vehicle Exhaust Duct - South (Lower)
Feature Insulating board shuttering panels to ceiling
Product Type Asbestos Insulating Board
Extent Amount 140 m
Recommendation Repair and/or Encapsulate
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage High damage - or delamination of materials, sprays and thermal insulation. Visible asbestos debris
3
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 9 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 280 Reference Number: As Sample BS021508
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor Mezzanine Floor
Area / Room 2M-002 Vehicle Exhaust Duct - North West (Upper)
Feature Insulating board shuttering panels to ceiling
Product Type Asbestos Insulating Board
Extent Amount 70 m
Recommendation Repair and/or Encapsulate
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage High damage - or delamination of materials, sprays and thermal insulation. Visible asbestos debris
3
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 9 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 281 Reference Number: As Sample BS021508
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor Mezzanine Floor
Area / Room 2M-003 Vehicle Exhaust Duct - North (Upper)
Feature Insulating board shuttering panels to ceiling
Product Type Asbestos Insulating Board
Extent Amount 70 m
Recommendation Repair and/or Encapsulate
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage High damage - or delamination of materials, sprays and thermal insulation. Visible asbestos debris
3
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 9 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Inspection Number 282 Reference Number: As Sample BS021508
Inspection / Sample Visually similar to Inspection Cross Reference / Visual I.D.
As Sample
Notes
Building Copperas Hill
Floor Level 2nd Floor Mezzanine Floor
Area / Room 2M-004 Vehicle Exhaust Duct - East (Lower)
Feature Insulating board shuttering to ceiling
Product Type Asbestos Insulating Board
Extent Amount 140 m
Recommendation Repair and/or Encapsulate
Product Score Medium Fibre Release - Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt
2
Extent of Damage High damage - or delamination of materials, sprays and thermal insulation. Visible asbestos debris
3
Surface Treatment Unsealed AIB, encapsulated lagging and sprays, ropes, textiles, paper
2
Asbestos Type Amosite 2
Normal occupant activity N/A N/A
Likelihood of disturbance N/A N/A
Accessibility N/A N/A
Extent / Amount N/A N/A
Average N/A
Number of occupants N/A N/A
Frequency of use of area N/A N/A
Average time area is in use
N/A N/A
Average N/A
Type of maintenance activity
N/A N/A
Frequency of maintenance activity
N/A N/A
Average N/A
Material Assessment Score 9 Priority Assessment Score N/A
2
Total Material Score N/A
WYG Environment Planning Transport Ltd Arndale Court, Headingley Leeds West Yorkshire LS6 2UJ
Contact Details: Tel: 0113 382 1052 Fax: 0113 278 3487 Email: [email protected] Web: www.wyg.com
Appendix C – Risk Assessment Criteria
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 343 of 386
.......................................................................................
Material Risk Assessment Product Type
Extent of Damage
Surface Treatment
Asbestos Type
Non asbestos containing materials are not scored.
SAMPLE VARIABLE SCORE EXAMPLES OF SCORE VARIABLES
Product type (or debris from product)
1 Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi–rigid paints or decorative finishes, asbestos cement etc)
2 Asbestos insulating board (AIB), mill boards, other low density insulation boards, asbestos textiles, gaskets, ropes and woven textiles, asbestos paper and felt
3 Thermal insulation (e.g. pipe and boiler lagging) sprayed asbestos, loose asbestos, asbestos mattresses and packing.
SAMPLE VARIABLE SCORE EXAMPLES OF SCORE VARIABLES
Extent of damage / deterioration
0 Good condition: no visible damage
1 Low damage: a few scratches or surface marks, broken edges on boards, tiles etc.
2 Medium damage: significant breakage of material or several small areas where material has been damaged revealing loose asbestos fibres
3 High damage or de–lamination: of materials, sprays and thermal insulation. Visible asbestos debris
SAMPLE VARIABLE SCORE EXAMPLES OF SCORE VARIABLES
Surface treatment 0 Composite materials containing asbestos: reinforced plastics, resins, vinyl tiles, asbestos cement (with exposed face painted or encapsulated)
1 Enclosed sprays and lagging, AIB with (exposed face painted or encapsulated), unsealed asbestos cement sheets etc.
2 Unsealed AIB or encapsulated lagging and sprays
3 Unsealed lagging and sprays
SAMPLE VARIABLE SCORE EXAMPLES OF SCORE VARIABLES
Asbestos type 1 Chrysotile
2 Amphibole asbestos excluding crocidolite (ie. Amosite)
3 Crocidolite
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 344 of 386
.......................................................................................
Appendix D – Site Sketches
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 345 of 386
.......................................................................................
Plenum
Chamber
Vehicle Exhaust Duct System
278
280
279
281
282
xxx
xxx
Appendix E – Analysis Certificates
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 355 of 386
.......................................................................................
ANALYSIS OF BULK MATERIALS FOR ASBESTOS
Client: Liverpool John Moores University LJMU Tower 24 Norton Street, Liverpool
Site: Former Royal Mail Sorting Office, Copperas Hill, Liverpool
Order Reference: N/A
Number of Samples: 112
Sample(s) taken by: Andy Noone, WYG
Date Received: 6th February 2014
Date Analysed: 6th February 2014
Analysed by: Peter Hurst
Analysed at: WYG EPT Ltd, Arndale Court
Method: Samples of materials, referenced as shown above, have been analysed qualitatively to determine the presence of asbestos fibres. Fibres in the sample were identified using a stereo microscope, polarised light and dispersion staining in accordance with in-house Procedure 07 based on Appendix 2 of HSG 248 'Asbestos: The analyst's guide for sampling, analysis and clearance procedures'.
Report Number: J004560
Report Date: 10 Apr 2015
WYG Environment Planning Transport Ltd
Arndale Court, Headingley
Leeds, LS6 2UJ
Phone: 0113 278 7111
Fax: 0113 275 0623
email: [email protected]
www.wyg.com
6060
www.wyg.com creative minds safe hands
Issuing Authority: Stephen Robinson (Deputy Quality & Technical Manager) Version: 3
Document: CERT01 Issue Date:
Page 356 of 386
.......................................................................................
RESULTS
Sample Reference Location Feature Material Type Type of Asbestos Detected
AR000237 1 - Roof room 3 tank room Residue to pipe work Insulation NADIS
AR000238 1 - Roof room 3 tank room Residue to pipe work Insulation NADIS
AR000239 1 - Roof room 3 tank room Debris to floor Insulation NADIS
AR000240 1 - Roof room 3 tank room Debris to floor Insulation NADIS
AR000241 2 - Roof room 4 lift motor room Mastic around door Well Bound Material NADIS
AR000243 3 - Roof room 6 lift motor room Insulating board lining to door Insulating Board NADIS
AR000244 4 - Roof room 5 tank room Residue to pipe work Insulation NADIS
AR000245 4 - Roof room 5 tank room Debris to floor Insulation NADIS
AR000246 4 - Roof room 5 tank room Cement pipe and jointing Asbestos Cement Chrysotile
AR000247 5 - Roof room 7a lift motor room Insulating board lining to door Asbestos Insulating Board Chrysotile
AR000248 5 - Roof room 7a lift motor room Bitumen in door frame Well Bound Material NADIS
WYG Group ......................................................................................................................creative minds safe hands
creative minds safe hands
...........................................................................................................www.wyg.com Issuing Authority: Stephen Robinson (Deputy Quality & Technical Manager) Version: 3
Document: CERT01 Issue Date:
Page 357 of 386
RESULTS
Sample Reference Location Feature Material Type Type of Asbestos Detected
AR000249 7 - Riser tower lift motor room Durasteel trap doors Asbestos Insulating Board Chrysotile
AR000251 9 - Roof lift motor room 2 Cladding to beams Insulating Board NADIS
AR000252 9 - Roof lift motor room 2 Floor tiles Reinforced Composite Chrysotile
AR000253 9 - Roof lift motor room 2 Mastic to wall column joints Reinforced Composite NADIS
AR000254 13 - Roof ventilation plant room 2 Mastic to ventilation duct jointing Reinforced Composite Chrysotile
AR000255 13 - Roof ventilation plant room 2 Bitumen above strammit ceiling Well Bound Material Chrysotile
AR000256 13 - Roof ventilation plant room 2 Loose gaskets Asbestos Textiles/Paper Chrysotile
AR000257 13 - Roof ventilation plant room 2 Insulating board lining to walls Asbestos Insulating Board Amosite
AR000258 14 - Roof ventilation plant room 1 Gaskets to pipework Asbestos Textiles/Paper Chrysotile
AR000259 14 - Roof ventilation plant room 1 Insulating board debris to floor Asbestos Insulating Board Chrysotile + Amosite
AR000260 14 - Roof ventilation plant room 1 Rope debris to ventilation ducting Textiles/Paper NADIS
WYG Group ......................................................................................................................creative minds safe hands
creative minds safe hands
...........................................................................................................www.wyg.com Issuing Authority: Stephen Robinson (Deputy Quality & Technical Manager) Version: 3
Document: CERT01 Issue Date:
Page 358 of 386
RESULTS
Sample Reference Location Feature Material Type Type of Asbestos Detected
AR000261 15 - Roof White promenade tile and associated debris
Cement NADIS
AR000262 15 - Roof Dark promenade tiles and associated debris
Cement NADIS
AR000263 1 - Lift lobby Putty to timber beading on doors Well Bound Material NADIS
AR000264 11 - Roof lift motor room 2 Lobby Riser Tower
Insulating board lining to door Asbestos Insulating Board Chrysotile
AR000265 2 - Lift lobby spiral staircase Insulating board lining to door Asbestos Insulating Board Chrysotile
AR000266 3 - Lift lobby riser Mastic to wall joints Well Bound Material Chrysotile
AR000267 5 - Room 30 Lockers Insulating board and associated debris in ceiling void
Asbestos Insulating Board Amosite
AR000268 6 - Riser tower upper and lower level
Coating to 3MF insulation in wall cavity
Textured Coating NADIS
AR000269 7 - Corridor Panels above windows Insulating Board NADIS
AR000270 7 - Corridor Mastic to ventilation duct joints Well Bound Material Chrysotile
AR000271 7 - Corridor Rope gaskets to pipe hangers in ceiling void
Asbestos Textiles/Paper Chrysotile
WYG Group ......................................................................................................................creative minds safe hands
creative minds safe hands
...........................................................................................................www.wyg.com Issuing Authority: Stephen Robinson (Deputy Quality & Technical Manager) Version: 3
Document: CERT01 Issue Date:
Page 359 of 386
RESULTS
Sample Reference Location Feature Material Type Type of Asbestos Detected
AR000272 26 - Male toilet riser Insulating board lining to door Asbestos Insulating Board Chrysotile
AR000273 26 - Male toilet riser Loose gaskets Asbestos Textiles/Paper Chrysotile
AR000274 27 - Male toilets Bitumen around pipe penetration in ceiling void
Well Bound Material NADIS
AR000275 33 - Room 14 Insulating board ceiling and associated debris in ceiling void
Asbestos Insulating Board Amosite
AR000276 38 - Room 90 Insulating board partition in ceiling void
Asbestos Insulating Board Amosite
AR000277 52 - Room 71 Store Mastic to door beading Reinforced Composite NADIS
AR000278 53 - Room 73 Secure area Insulating board lining to door Asbestos Insulating Board Chrysotile
AR000279 53 - Room 73 Secure area Rope to pipe hanger in ceiling void Asbestos Textiles/Paper Chrysotile
AR000280 53 - Room 73 Secure area Resin to counters Reinforced Composite NADIS
AR000281 55 - Rooms 60 - 62 Room 62 Green vinyl under carpet Reinforced Composite NADIS
AR000282 57 - Rooms 65 Red vinyl under carpet Reinforced Composite NADIS
WYG Group ......................................................................................................................creative minds safe hands
creative minds safe hands
...........................................................................................................www.wyg.com Issuing Authority: Stephen Robinson (Deputy Quality & Technical Manager) Version: 3
Document: CERT01 Issue Date:
Page 360 of 386
RESULTS
Sample Reference Location Feature Material Type Type of Asbestos Detected
AR000283 59 - Room 66 Blue vinyl to floor Reinforced Composite NADIS
AR000284 60 - Room 85 Syphon Textured coating to ceiling Textured Coating NADIS
AR000285 63 - Room 95 Kitchen Insulating board to ceiling Insulating Board NADIS
AR000286 75 - Shop Sink pad Well Bound Material Chrysotile
AR000287 79 - Room 4 Dining room/servery Insulating board lining to door Insulating Board NADIS
AR000288 79 - Room 4 Dining room/servery Beading to door Insulating Board NADIS
AR000289 2 - Main riser Insulating board lining to door Asbestos Insulating Board Chrysotile
AR000290 2 - Main riser Mastic to wall joints (both rooms) Reinforced Composite Chrysotile
AR000291 3 - Room 20 Riser Tower Durasteel cladding to wall (high and low level)
Asbestos Insulating Board Chrysotile + Amosite
AR000292 4 - Lift lobby riser Insulating board lining to door Asbestos Insulating Board Chrysotile
AR000293 7 - Mezzanine offices North Vinyl floor tiles beneath carpet Reinforced Composite NADIS
WYG Group ......................................................................................................................creative minds safe hands
creative minds safe hands
...........................................................................................................www.wyg.com Issuing Authority: Stephen Robinson (Deputy Quality & Technical Manager) Version: 3
Document: CERT01 Issue Date:
Page 361 of 386
RESULTS
Sample Reference Location Feature Material Type Type of Asbestos Detected
AR000294 16 - Rooms 26-30 Mastic to wall expansion joints Well Bound Material NADIS
AR000295 17 - Room 23-24 Toilet Riser Insulating board lining to door Asbestos Insulating Board Chrysotile
AR000296 25 - Room 54 Male WC Resin WC cisterns Reinforced Composite NADIS
AR000297 34 - Lift Moor Room for LSG001 Cement brake shoes to lift motor Reinforced Composite NADIS
AR000298 3 - North Locker Room Putty seal to HVAC ducting in ceiling void
Well Bound Material Chrysotile
AR000299 5 - Conveyor gallery AIB wall panels Asbestos Insulating Board Amosite
AR000300 5 - Conveyor gallery Grey vinyl floor tiles Reinforced Composite NADIS
AR000301 9 - South East Female WC Bitumen acoustic pads in Water Bunnies x2
Well Bound Material NADIS
AR000302 1 - Room 34 Entrance lobby/Reception
Insulating board infills above windows
Insulating Board NADIS
AR000303 1 - Room 34 Entrance lobby/Reception
Textured coating to ceiling and above lift doors
Textured Coating NADIS
AR000304 1 - Room 34 Entrance lobby/Reception
Supalux boarding to ceiling and in ceiling void
Insulating Board NADIS
WYG Group ......................................................................................................................creative minds safe hands
creative minds safe hands
...........................................................................................................www.wyg.com Issuing Authority: Stephen Robinson (Deputy Quality & Technical Manager) Version: 3
Document: CERT01 Issue Date:
Page 362 of 386
RESULTS
Sample Reference Location Feature Material Type Type of Asbestos Detected
AR000305 3 - Room 38 Loading Bays IB cladding/fascia above loading bay doors
Insulating Board NADIS
AR000306 3 - Room 38 Loading Bays IB infill to ceiling expansion joint and debris to conduit
Asbestos Insulating Board Amosite
AR000307 3 - Room 38 Loading Bays Vicuclad beam cladding Insulating Board NADIS
AR000308 3 - Room 38 Loading Bays T/C to beam cladding Textured Coating NADIS
AR000309 1 - North Lift Lobby IB lining to double doors to stairwell. Asbestos Insulating Board Chrysotile
AR000310 3 - Room 38 Loading Bays Mastic to ventilation duct jointing Reinforced Composite Chrysotile
AR000312 3 - Room 38 Loading Bays Insulating board shuttering to ventilation duct
Asbestos Insulating Board Amosite
AR000313 13 - Room 43 Lobby Insulating board lining to door Asbestos Insulating Board Chrysotile
AR000314 18 - Room 55 Vinyl floor tiles Reinforced Composite NADIS
AR000315 20 - Room 21 Safe Textured coating to walls and ceiling Textured Coating NADIS
AR000316 24 - Rooms 12 and 9 Floor tiles Reinforced Composite NADIS
WYG Group ......................................................................................................................creative minds safe hands
creative minds safe hands
...........................................................................................................www.wyg.com Issuing Authority: Stephen Robinson (Deputy Quality & Technical Manager) Version: 3
Document: CERT01 Issue Date:
Page 363 of 386
RESULTS
Sample Reference Location Feature Material Type Type of Asbestos Detected
AR000317 25 - Rooms 6, 45, 46 Priority services and offices
Floor tiles Reinforced Composite NADIS
AR000318 34 - Room 18 Mezz plant room Mastic to ventilation duct jointing Reinforced Composite Chrysotile
AR000319 17 - Room 17 above G6 lift Floor tiles Reinforced Composite Chrysotile
AR000320 1 - Room 29 Boiler Room Insulating board shuttering to foul chamber
Asbestos Insulating Board Chrysotile + Amosite
AR000321 1 - Room 29 Boiler Room Dust/debris to floor channel Dust/Debris Amosite
AR000322 1 - Room 29 Boiler Room Dust/debris in floor channel Dust/Debris NADIS
AR000323 1 - Room 29 Boiler Room Rope gasket to boiler Asbestos Textiles/Paper Chrysotile
AR000324 1 - Room 29 Boiler Room Rope gasket to boiler Asbestos Textiles/Paper Chrysotile
AR000325 1 - Room 29 Boiler Room Rope gasket to boiler Asbestos Textiles/Paper Chrysotile
AR000326 1 - Room 29 Boiler Room Loose gasket Textiles/Paper NADIS
AR000327 1 - Room 29 Boiler Room Gaskets to pipe work throughout Textiles/Paper NADIS
WYG Group ......................................................................................................................creative minds safe hands
creative minds safe hands
...........................................................................................................www.wyg.com Issuing Authority: Stephen Robinson (Deputy Quality & Technical Manager) Version: 3
Document: CERT01 Issue Date:
Page 364 of 386
RESULTS
Sample Reference Location Feature Material Type Type of Asbestos Detected
AR000328 1 - Room 29 Boiler Room Residue to pipe work Dust/Debris NADIS
AR000329 1 - Room 29 Boiler Room Mastic to vent duct joints Reinforced Composite Chrysotile
AR000331 3 - Lift lobby x2 S/W Tower Mastic to window glazing of double fire doors
Well Bound Material NADIS
AR000332 7 - Rooms 19-23 IB noticeboard Insulating Board NADIS
AR000333 12 - Room 1 Union Room DPC to window void Well Bound Material NADIS
AR000334 15 - Room 6 Addressograph Store Vinyl floor tiles and bitumen adhesive below
Reinforced Composite Chrysotile
AR000335 16 - Entrance to Service Centre Board to canopy Insulating Board NADIS
AR000336 19 - Fume Extract and Plenum Chamber (accessed via 37)
Vinyl expansion collars to vent ducting
Reinforced Composite NADIS
AR000337 20 - Room 29a Engineers Workshop and 30 Electric
DPC within floor service hatch Well Bound Material NADIS
AR000338 20 - Room 29a Engineers Workshop and 30 Electric
Resin panel to electrical switch gear Well Bound Material Chrysotile
AR000339 22 - Room 24 - 27 IB wall partions Insulating Board NADIS
WYG Group ......................................................................................................................creative minds safe hands
creative minds safe hands
...........................................................................................................www.wyg.com Issuing Authority: Stephen Robinson (Deputy Quality & Technical Manager) Version: 3
Document: CERT01 Issue Date:
Page 365 of 386
RESULTS
Sample Reference Location Feature Material Type Type of Asbestos Detected
AR000340 17 - Plant Room and Substation External Canopy
CAF gasket to pipework Asbestos Textiles/Paper Chrysotile
AR000341 1 - G4 (LPG 009) Textured coating to walls Textured Coating NADIS
AR000342 2 - G2 (LPG 007) Textured coating to walls Textured Coating NADIS
AR000343 3 - G1 (LPG 006) IB beam cladding Insulating Board NADIS
AR000344 4 - P1-3 Passenger Lift IB wall panels Asbestos Insulating Board Amosite
AR000345 4 - P1-3 Passenger Lift Mastic to wall expansion joint Well Bound Material Chrysotile
AR000346 33 - Room 56, main floor area Rubber beading to curtain wall at high level
Well Bound Material NADIS
AR000357 18 - West Tower Loading bay (Level 1)
Millboard canopy above loading bay doors
Asbestos Insulating Board Chrysotile
BS011674 - Wash Cabin Felt to external roof Well Bound Material NADIS
BS011675 - Security Box Red Floor Tiles Reinforced Composite NADIS
BS011676 - Wash Cabin Seal to lights adjacent to wash cabin wall
Well Bound Material NADIS
WYG Group ......................................................................................................................creative minds safe hands
creative minds safe hands
...........................................................................................................www.wyg.com Issuing Authority: Stephen Robinson (Deputy Quality & Technical Manager) Version: 3
Document: CERT01 Issue Date:
Page 366 of 386
RESULTS
Key: NADIS = No Asbestos Detected in Sample
J004560
Sample Reference Location Feature Material Type Type of Asbestos Detected
BS021507 Level 3 Ventilation Ducts Debris In and Under Duct Lid Dust/Debris NADIS
BS021508 Level 3 Ventilation Ducts IB Shuttering Debris to Grille Inside Duct
Asbestos Insulating Board Amosite
REPORTED BY Name: Peter Hurst Position: Bulk Sample Analyst
Disclaimer.
Opinions and interpretations, including the description of material type, are outside the scope of our UKAS accreditation. Results apply only to the sample(s) listed in the table above. WYG Environment Ltd accepts no responsibility for errors which may have arisen during sampling or transportation and cannot take responsibility for the accuracy, representative nature and location of samples taken by external customers. This test report shall not be reproduced except in full without the written approval of WYG Environment Ltd
WYG Group ......................................................................................................................creative minds safe hands
creative minds safe hands
...........................................................................................................www.wyg.com Issuing Authority: Stephen Robinson (Deputy Quality & Technical Manager) Version: 3
Document: CERT01 Issue Date:
Page 367 of 386
Appendix F – Descriptions of general items in each room
Area Description of Materials
Copperas Hill
External
1. Roof room 3 tank room Concrete walls, floors and ceiling, 3MF lagged pipe work, brick plinths to tanks, polystyrene lagging to metal tanks. Non suspect loose roofing felt.
2. Roof room 4 lift motor room
Concrete walls, floors and ceiling. Timber boxing, metal and timber trap doors. Modern lift motor.
3. Roof room 6 lift motor room
Concrete walls, floors and ceiling. Timber boxing, metal and timber trap doors. Modern lift motor.
4. Roof room 5 tank room Concrete walls, floors and ceiling, 3MF lagged pipe work, brick plinths to tanks, 3MF lagging to metal tanks.
5. Roof room 7a lift motor room
Concrete floor, walls and ceiling. Modern lift motor, no access to brakes.
6. Roof room 7b tank room Concrete walls, floor and ceiling, 3MF lagged pipes, foam and polystyrene lagged metal tanks
7. Riser tower lift motor room
Metal ceiling, breeze block walls, concrete floor, non asbestos vibration dampers
8. Riser tower lift motor room lower level
Concrete floor and ceiling, brick walls, metal stairs. Non suspect rope gasket to exhaust.
9. Roof lift motor room 2 Solid floor, concrete floor, block walls, timber boxing with plastic pipe inside.
10. Roof lift motor room 2 lobby
Concrete floor, block walls, concrete ceiling
11. Roof lift motor room 2 Lobby Riser Tower
Concrete floor and ceiling, block walls, timber boxing with 3MF pipe work
12. Roof lift motor room 2 upper level tank room
Concrete floor, block walls, metal roof.
13. Roof ventilation plant room 2
Concrete floor, brick walls, strammit ceiling, metal ventilation ducting.
14. Roof ventilation plant room 1
Concrete floor, brick walls, strammit ceiling, metal ventilation ducting.
15. Roof Modern bitumen felt, foam, profiled steel construction
16. Entrance to Service Centre
Board soffit with brick walls and ceramic floor.
17. Plant Room and Substation External Canopy
Concrete upper with vicuclad beam cladding. Brick walls, alli clad 3MF pipe insulation. Timber door infill.
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 368 of 386
.......................................................................................
18. West Tower Loading bay (Level 1)
. Wash Cabin Internal - Timber floor, walls and ceiling. Modern metal tank, poly ins. Modern uPVC pipework. Modern pump, etc. External - Timber clad, sampled felt to roof
. Security Box Internal - Timber floor, timber walls to poly and mmmf foil backed ins and timber with metal mesh and poly ins to ceiling. External - Timber clad with sampled roof felt
. Main Entrance Modern roof felt. Metal edging
External. Window Infills (Behind Brown Panels)
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 369 of 386
.......................................................................................
Area Description of Materials
1st Floor
1. Room 12 Lift lobby Concrete upper and floor. Block walls with vicuclad beam cladding. Non suspect vinyl flooring.
2. Room 11 and 13 Sensitive Waste
Concrete upper and floor. Block walls with vicuclad beam cladding. Non suspect vinyl flooring.
3. Room 3 and 10 Concrete upper, block walls, vicuclad beam cladding. Concrete floor with non suspect vinyl.
4. Room 5 - 9 Concrete upper, block walls, vicuclad beam cladding. Concrete floor with non suspect vinyl.
5. Room 4 Concrete upper, block walls, vicuclad beam cladding. Concrete floor with non suspect vinyl.
6. West Tower Corridor
Concrete upper, block walls, vicuclad beam cladding. Concrete floor with non suspect vinyl. Plasterboard ceiling tiles.
7. Room 1 and 2 Concrete upper, block wall. Concrete floor with non suspect vinyl. Plasterboard ceiling tiles. 3MF pipe insulation.
. Throughout Level 1
2nd Floor
1. Room 29 Boiler Room
2. Room 28 Tank Room
Concrete floor and ceilings, block walls.
3. Lift lobby x2 S/W Tower
Concrete upper,plasterboard tiles, concrete walls and floor and non suspect vinyl.
4. Male WC S/W Tower
Concrete upper,plasterboard tiles, concrete walls and floor with ceramic tiles. 3MF pipe insulation. Porcelain cisterns. Modern fixtures and fittings. Timber shuttering to ceiling of riser. Metal and plastic pipes.
5. Store S/W Tower Concrete upper,plasterboard tiles, concrete walls and floor with ceramic tiles. 3MF pipe insulation. . Modern fixtures and fittings. Timber shuttering to ceiling of riser. Metal and plastic pipes.
6. Main Corridor Concrete upper, block walls, vicuclad beam cladding, 3MF pipe insulation. Concrete floor with non suspect vinyl.
7. Rooms 19-23 Concrete upper, block walls, vicuclad beam cladding, 3MF pipe insulation. Concrete floor with non suspect vinyl. N/A to safe locked.
8. Rooms 17 and 18 Concrete upper, block walls, vicuclad beam cladding, 3MF pipe insulation. Concrete floor with carpet tiles.
9. Rooms 2a,b and c (West)
Concrete upper, block and timber walls. Vicuclad beam cladding. Concrete floor with non suspect vinyl.
10. Room 2 Cleaners (West)
Concrete upper with plasterboard ceiling tiles. 3MF pipe insulation. Ceramic tiles to floor. Metal and plastic pipes.
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 370 of 386
.......................................................................................
11. Lift lobby West Tower
Concrete upper,plasterboard tiles, concrete walls and floor and non suspect vinyl.
12. Room 1 Union Room
Concrete upper,plasterboard tiles, concrete walls and floor and non suspect vinyl.
13. Room 2 Female WC W Tower
Concrete upper,plasterboard tiles, concrete walls and floor with ceramic tiles. 3MF pipe insulation. Porcelain cisterns. Modern fixtures and fittings. Timber shuttering to ceiling of riser. Metal and plastic pipes.
14. Room 5 Addressograph Room
Concrete soffit, solid block/conc walls and lino to conc floor. 3MF ceiling tiles and insulation to pipes. Metal collars to pipe penetrations. Vicuclad RSJs.
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 371 of 386
.......................................................................................
Area Description of Materials
15. Room 6 Addressograph Store
Concrete soffit, solid block/conc walls and vinyl to conc floor. Vicuclad RSJs.
16. Rooms 7-9, 14-15 Classrooms 1 and 2 and adjacent
Concrete soffit, solid block/conc walls and vinyl to conc floor. Timber and fibreboard (no lining) partitions. Vicuclad RSJs.
17. Rooms 10 - 13 Callers Office and associated areas
Concrete soffit, solid block/conc walls and vinyl to conc floor. Timber and plasterboard partitions. Modern suspended ceiling. Vicuclad RSJs.
18. Room 35 - 36 Concrete upper, block walls, concrete floor. 3MF pipe insulation, vicuclad beam and RSJ cladding.Timber doors. Concrete riser adjacent to compressors.
19. Fume Extract and Plenum Chamber (accessed via 37)
Concrete upper and walls with IB shuttering.
20. Room 29a Engineers Workshop and 30 Electric
Concrete floor, brick walls, concrete ceiling. Metal clad and foil wrapped 3MF insulation to pipe work. Vicuclad to beams and RSJs. Metal partions.
21. Room 38 and 39 Concrete floor, brick walls, concrete ceiling. Metal clad and foil wrapped 3MF insulation to pipe work. Vicuclad to beams and RSJs.
22. Room 24 - 27 Concrete floor, brick walls, concrete ceiling. Metal clad and foil wrapped 3MF insulation to pipe work. Vicuclad to beams and RSJs. Supalux wall partitions. Timber raised floor.
. Throughout Level 2
Riser Tower. Conveyor to Tunnel Block walls, metal ceilings and metal chutes.
3rd Floor
1. Room 34 Entrance lobby/Reception
Vinyl and carpeted concrete floor, brick walls timber and plasterboard partition walls, 3MF suspended ceiling tiles concrete above.
2. Room 37 Concrete floor and ceiling, brick walls
3. Room 38 Loading Bays Concrete upper and floors. Block and brick walls. Vicuclad beam and RSJs cladding. Metal ducting and pipework.
4. Security viewing galleries throughout.
Timber floors, plasterboard walls, strammit ceilings
5. Room 35 Male WC Tiled concrete floor, solid walls, 3MF ceiling tiles concrete above.
6. Room 36 Riser Concrete floor, concrete ceiling, solid walls
7. Room 33 Carpeted timber floor, solid walls, plasterboard partitions, 3MF ceiling tiles concrete above.
8. Room 39 Revenue Management
Concrete floor, solid walls, timber partition walls, concrete and plaster ceiling.
9. Room 40 Vinyl concrete floor, solid walls, timber partition walls, plaster ceiling.
10. Room 41 Carpeted concrete floor, solid walls, plaster and timber partition walls, 3MF
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 372 of 386
.......................................................................................
ceiling tiles concrete above.
11. Room 61 (above room 41) Vinyl concrete floor, solid walls, concrete ceiling
12. Room 42 Male WC Solid tiled floor, solid walls, 3MF ceiling tiles concrete above.
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 373 of 386
.......................................................................................
Area Description of Materials
13. Room 43 Lobby Concrete floor, solid walls, concrete ceiling
13. Room 33 Solid walls, concrete floor and ceiling
14. Lift motor rooms in main loading bay
Block walls, concrete floor, metal roof
14. Room 52 Tiled concrete floor, solid walls, 3 MF ceiling tiles concrete above. Refer to item 170 for wall cladding to the exterior of the 3 Mezzanine chain enclosure at high level.
15. Room 50 Concrete floor, solid walls, concrete ceiling. Refer to item 170 for wall cladding to the exterior of the 3 Mezzanine chain enclosure at high level.
15. Room 24 Sorting area Concrete floor, solid walls, concrete ceiling
16. Room 56 Concrete floor, solid walls, concrete ceiling.
17. Room 54 Vinyl concrete floor, solid walls, 3 MF ceiling tiles concrete above.
18. Room 55 Vinyl tiled concrete floor, solid walls, concrete ceiling.
19. Welfare enclosures 15, 16, 17, 18
Vinyl concrete floor, solid walls, metal/timber partition walls, metal ceiling tiles concrete above.
20. Room 21 Safe Concrete floor, concrete ceiling, sold walls
21. Room 22 Carpeted concrete floor, solid walls, plaster ceiling concrete above
22. Room 23 Concrete floor, solid walls, concrete ceiling
23. Room 20 Carpeted concrete floor, solid walls, plaster ceiling timber above
24. Rooms 12 and 9 Vinyl concrete floor, solid walls, metal ceiling
25. Rooms 6, 45, 46 Priority services and offices
Vinyl tile concrete floor, solid walls, timber partition wall, plasterboard ceiling tiles concrete above.
26. Room 10 Corridor and Lobby
Vinyl concrete floor, solid walls,timber partition wall, plasterboard ceiling tiles timber above.
27. Rooms 25, 26, 27 and 29
Carpeted concrete floor, solid walls, timber partition walls, timber ceiling
28. Room 28 Strong room Vinyl concrete floor, solid walls, solid ceilings
29. Room 31 Vinyl concrete floor, solid walls, solid ceiling
30. Room 30 Male WC Tiled concrete floor, solid walls, plasterboard ceiling tiles concrete above
31. Rooms 57, 58, 59, 60 Vinyl concrete floor, solid walls, timber partition walls, timber ceilings
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 374 of 386
.......................................................................................
Area Description of Materials
32. Rooms 1, 3, 4, 5 Vinyl concrete floor, solid walls, plasterboard ceiling tiles concrete.
33. Rooms 2 and 7 Toilets
Tiled concrete floor, solid walls, plasterboard ceiling tiles concrete.
. Throughout Level 3
Riser Tower. Conveyor to Tunnel
Block walls with durasteel infills. Metal floor and ceiling. Vicuclad beam and RSJ cladding.
4th Floor
1. Room 25 Lift Lobby
Vinyl concrete floor, solid walls, 3MF ceiling tiles concrete above
2. Rooms 23 and 24 Toilets
Tiled floor, solid walls, 3MF ceiling tiles concrete above
3. Room 20 Riser Tower
Concrete and metal floor, solid walls, metal ceiling
4. Lift lobby riser Metal floor and ceiling, block walls
5. Room 19 OCR Training
Carpeted concrete floor, solid walls, plasterboard partition walls, 3MF ceiling tiles timber above
6. Rooms 15, 17, 18 Carpeted concrete floor, solid walls, timber partition walls, plasterboard ceiling
7. Room 14 Carpeted concrete floor, solid walls, timber partition walls, metal mesh ceiling
8. Above Room 19 Carpeted timber floor, solid walls, plasterboard partition walls, 3MF ceiling tiles concrete above
9. Security viewing gallery
Plasterboard walls, strammit ceilings, solid floors
10. Rooms 26-27 Concrete celing, solid and plasterboard walls. Vicuclad cladding and plaster to beams and RSJs. Vinyl and concrete floors.
11. Rooms 29 Concrete celing, plasterboard ceiling tiles solid and plasterboard walls. Vicuclad cladding and plaster to beams and RSJs. Vinyl and concrete floors.
12. Rooms 28 Concrete celing, plasterboard ceiling tiles solid and plasterboard walls. Vicuclad cladding and plaster to beams and RSJs. Vinyl and concrete floors.
13. Rooms 30 Concrete celing, solid and plasterboard walls. Vicuclad cladding and plaster to beams and RSJs. Concrete floor.
14. Rooms 31-35 Concrete celing, solid and plasterboard walls. Vicuclad cladding and plaster to beams and RSJs. Concrete floor, timber plinth to shower and tiled timber boxing to radiator in shower room.
15. Room 37 Safe
16. Rooms 26-30 Concrete celing, plasterboard ceiling tiles solid and plasterboard walls. Vicuclad cladding and plaster to beams and RSJs. Vinyl and concrete floors.
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 375 of 386
.......................................................................................
17. Room 23-24 Toilet Riser
Metal floor and ceiling, block walls
18. Room 36 Chain enclosure
Concrete celing, solid and plasterboard walls. Vicuclad cladding and plaster to beams and RSJs. Concrete floor, timber infill adjacent windows.
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 376 of 386
.......................................................................................
Area Description of Materials
19. Rooms 38-39
Hessian-backed vinyl flooring to solid floor. Concrete, block and timber walls, hessian-backed vinyl covering to timber worktops, timber doors.
20. Room 40 Female wc
Quarry tile floor on solid. Timber wall panels, plastic soil pipes, MMMF insulation to pipework, plastic cisterns, ceramic sluice, plywood and plasterboard tiled wall to cleaners cupboard, timber doors. Fibreboard suspended ceiling tiles, concrete above, vicuclad beam cladding, supalux shuttering to pipe penetrations.
21. Room 41 Lift Lobby
Bitumen screed to concrete floor. Solid walls, plywood walls. Plasterboard ceiling tiles, concrete above
22. Riser adjacent room 41
Metal floor and ceiling, block walls, plastic downpipe.
23. Riser adjacent room 55
Metal floor and ceiling, block walls.
24. Room 55 Lift Lobby
Bitumen screed to concrete floor. Solid walls, timber doors, metal doors. Plasterboard ceiling tiles, concrete above, MMMF insulation to pipework in ceiling void.
25. Room 54 Male WC
Quarry tile floor on solid. Timber riser panels, plastic soil pipes, MMMF insulation to pipework, ceramic urinal cisterns, ceramic sluice, timber doors. Plasterboard suspended ceiling tiles, concrete above.
26. South West Lift Lobby
Bitumen screed to concrete floor. Solid walls, timber doors, timber and glass hatch to fire riser. Plasterboard ceiling tiles, concrete above.
27. Room 48 Male WC
Quarry tile floor on solid. Timber riser panels, plastic soil pipes, MMMF insulation to pipework, ceramic urinal cisterns, ceramic sluice, timber doors. Plasterboard suspended ceiling tiles, concrete above.
28. Room 47 Male wc
Quarry tile floor on solid. Timber wall panels, plastic soil pipes, MMMF insulation to pipework, plastic cisterns,timber doors. Plasterboard suspended ceiling tiles, concrete above, supalux packing to HVAC.
29. Room 46-42
Bitumen screed to concrete floor. Concrete external walls, plasterboard partitions, concrete columns, plasterboard boxing to steel curtain wall hanger plates, metal radiators, timber beam bolted to concrete external wall, modern bitumen sink pad to steel sink, timber doors. Wire mesh ceilings, plasterboard ceilings, void above, plywood infills above windows.
30. West Stair Lobby
Modern vinyl on concrete floor. Solid walls, timber doors. Plasterboard ceiling tiles, concrete above.
31. Room 2, cleaners
Quarry tile floor on solid. Timber riser panels, plastic soil pipes, MMMF and foam insulation to pipework, ceramic sluice, timber door. Plasterboard suspended ceiling tiles, concrete above.
32. Room 1 Female wc
Quarry tile floor on solid. Timber wall panels, plastic soil pipes, MMMF insulation to pipework, plastic cisterns, timber doors. Plasterboard suspended ceiling tiles, concrete above, modern HVAC.
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 377 of 386
.......................................................................................
33. Room 56, main floor area
Floor, Bitumen screed on glass-fibre mat on sand on concrete slab with steel rebar. Walls and services: External cladding panels are concrete (with rebar) curtain walling on steel hangers fixed to concrete columns and intermediate steel columns. Fixings are concealed with plasterboard and plaster on wire mesh. A rubber seal is between the upper edge of the cladding panels and the ring beam. G6 and G7 goods lift shafts are concrete and block walled with metal fascias and concrete canopies. Pipework spanning expansion joints has rubber gaskets and flexi-couplings. Plywood boxing to paired columns at expansion joints conceals a HV cable riser with vermiculite firebreaks. Nylon and glass-fibre flexible sections and MMMF bracket pads to HVAC. Conveyors consist of steel catwalks and chassis with nylon conveyor belts and steel/rubber rollers with GRP chutes and slides. Ceilings, Ceilings are concrete slab throughout with vicuclad cladding to RSJs. Perimeter soffits are concrete.
34. Lift Moor Room for LSG001
Concrete floor with steel floor hatch, timber shuttering to cable penetrations to shaft. AIB wall cladding, vicuclad beam cladding, hessian wadding to lift motor mounting plates, modern electrics, timber door. Concrete ceiling, steel lifting beam.
5th Floor
1. Lift lobby
Concrete floor with modern vinyl covering, block and brick walls, 3MF concrete above. 3MF lagged pipework in ceiling void.
2. Lift lobby spiral staircase
Block walls, metal stairs, concrete floor
3. Lift lobby riser
Block walls, concrete ceiling, concrete floor timber boxing
4. Room 31 Cleaners
Ceramic tiled floor, solid walls, plasterboard ceiling tiles metal above.
5. Room 30 Lockers
Concrete floor, with modern vinyl covering, block walls, plasterboard ceiling tiles metal above.
6. Riser tower upper and lower level
Block walls, metal stairs, concrete floor, metal ceiling
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 378 of 386
.......................................................................................
Area Description of Materials
7. Corridor Concrete floor with modern vinyl covering, block walls, 3MF suspended ceiling tiles metal roof above. Metal RSJ's some with non asbestos vermiculite cladding and fibre board packers. Metal ventilation ducting, 3MF lagged pipe work.
8. Room 34 Carpeted concrete floor, plasterboard partition walls, block walls, 3MF suspended ceiling metal above. Timber infills.
9. Room 34a Modern vinyl covered concrete floor, plasterboard partition walls, block walls, 3MF fixed suspended ceiling metal above.
10. Room 33 Toilets
Concrete floors with modern vinyl covering, ceramic tiled walls, 3MF suspended ceiling tiles metal above.
11. Room 33a Records Room
Metal roof, block walls, concrete floor with modern vinyl covering.
12. Room 38 Training
Carpeted concrete floor, block walls, 3MF suspended ceiling metal above.
13. Room 39 Carpeted concrete floor, block walls, 3MF suspended ceiling metal above.
14. Rooms 40 and 41
Carpeted concrete floor, block walls, 3MF suspended ceiling metal above.
15. Room 42 Carpeted concrete floor, block walls, 3MF suspended ceiling metal above.
16. Room 43 Concrete floor with modern vinyl covering, block walls, 3MF ceiling tiles metal above
17. Room 44 Concrete floor with modern vinyl covering, block walls, 3MF ceiling tiles metal above
18. Room 48 Carpeted concrete floor, block walls, 3MF suspended ceiling metal above.
19. T.P.M. Library Carpeted concrete floor, block walls, plaster and timber partition walls, 3MF ceiling tiles metal above
20. Waiting room Carpeted concrete floor, block walls, plaster and timber partition walls, 3MF ceiling tiles metal above
21. Room 47 A.C.M. Store
Concrete floor with modern vinyl covering, block walls, 3MF ceiling tiles metal above
22. Room 46 Office Carpeted concrete floor, block walls, 3MF suspended ceiling metal above.
23. Room 45 Resource Section
Carpeted concrete floor, block walls, 3MF suspended ceiling metal above.
24. Revenue Management
Carpeted concrete floor, block walls, 3MF suspended ceiling metal above.
25. Room 35 Classroom 3
Carpeted concrete floor, block walls, 3MF suspended ceiling metal above.
26. Male toilet riser Metal roof, metal floor, block walls, 3MF lagged pipe work
27. Male toilets Tiled floor and walls, 3MF ceiling tiles metal above
28. Room 10 Carpeted concrete floor, block walls, 3MF ceiling tiles, metal above
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 379 of 386
.......................................................................................
Female Lockers
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 380 of 386
.......................................................................................
Area Description of Materials
29. Room 32 Female Toilets
Tiled walls and floor, 3MF ceiling tiles metal above
30. Room 16 Lockers Modern vinyl concrete floor, block walls, 3MF ceiling tiles, metal above
31. Room 13 Lockers Modern vinyl concrete floor, block walls, 3MF ceiling tiles, metal above
32. Room 17 Societies Modern vinyl concrete floor, block walls, 3MF ceiling tiles, metal above
33. Room 14 Modern vinyl concrete floor, block walls, insulating board ceiling.
34. Room 86 Carpeted concrete floor, block walls, timber and plaster partitions, 3MF ceiling tiles metal above
35. Room 87 Carpeted concrete floor, block walls, timber and plaster partitions, 3MF ceiling tiles metal above
36. Room 88 Carpeted concrete floor, block walls, timber and plaster partitions, 3MF ceiling tiles metal above
37. Room 89 Carpeted concrete floor, block walls, timber and plaster partitions, 3MF ceiling tiles metal above
38. Room 90 Carpeted concrete floor, block walls, timber and plaster partitions, 3MF ceiling tiles metal above
39. Room 98 Carpeted concrete floor, block walls, timber and plaster partitions, 3MF ceiling tiles metal above
40. Room 93 Tiled walls, vinyl floor, 3MF ceiling tiles metal above
41. Room 94 Tiled walls, vinyl floor, 3MF ceiling tiles metal above
42. Room 59 Carpeted concrete floor, block walls, 3MF suspended ceiling metal above.
43. Rooms 58 and 57 Carpeted concrete floor, block walls, 3MF suspended ceiling metal above.
44. Rooms 56 Carpeted concrete floor, block walls, 3MF suspended ceiling metal above.
45. Rooms 55 Carpeted concrete floor, block walls, 3MF suspended ceiling metal above.
46. Room 54 Carpeted concrete floor, block walls, 3MF suspended ceiling metal above.
47. Room 53 Carpeted concrete floor, block walls, 3MF suspended ceiling metal above.
48. Rooms 46b, 46c, 46d, 46e
Carpeted concrete floor, block walls, plasterboard partition walls, 3MF ceiling tiles, metal above
49. Rooms 46 and 46a Carpeted concrete floor, block walls, plasterboard partition walls, 3MF ceiling tiles, metal above
50. Room 47 and Store Carpeted concrete floor, block walls, plasterboard partition walls, 3MF ceiling tiles, metal above
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 381 of 386
.......................................................................................
Area Description of Materials
51. Rooms 48, 49, 51, 52
Modern vinyl covered concrete floor, block walls, plasterboard partition walls, 3MF ceiling tiles, metal above
52. Room 71 Store Modern vinyl covered concrete floor, block walls, plasterboard partition walls, 3MF ceiling tiles, metal above
53. Room 73 Secure area
Modern vinyl covered concrete floor, block walls, plasterboard partition walls have been removed leaving one open plan area, 3MF ceiling tiles, metal above.
54. Medical Suite Rooms 100 - 108
Concrete carpeted and vinyl floors, block walls, timber partitions, 3MF ceiling tiles metal above
55. Rooms 60 - 62 Carpeted and vinyl concrete floor, solid walls plasterboard partitions, 3MF ceiling tiles concrete above
56. Room 63 Vinyl concrete floor, solid walls, 3MF ceiling tiles
57. Rooms 65 Carpeted and vinyl concrete floor, solid walls plasterboard partitions, 3MF ceiling tiles concrete above
58. Room 64 Vinyl concrete floor, solid walls, 3MF ceiling tiles concrete above
59. Room 66 Vinyl concrete floor, solid walls, 3MF ceiling tiles concrete above
60. Room 85 Syphon Vinyl concrete floor, solid walls, plaster ceiling
61. Room 67 Vinyl concrete floor, solid walls, plaster ceiling
62. Room 68 Vinyl concrete floor, solid walls, timber partition walls, 3MF ceiling tiles metal above
63. Room 95 Kitchen Modern vinyl concrete floor, solid walls, supalux ceiling metal above.
64. Room 97 Carpeted concrete floor, solid walls, 3MF ceiling tiles metal above
65. Room 84 Carpeted concrete floor, solid walls, plasterboard partition walls, plaster ceiling metal above
66. Room 99 Carpeted concrete floor, solid walls, plasterboard partition walls, 3MF ceiling tiles metal above
67. Room 29 Carpeted concrete floor, solid walls, 3MF ceiling tiles metal above
68. Room 28 Carpeted concrete floor, solid walls, 3MF ceiling tiles metal above
69. Room 27 Carpeted concrete floor, solid walls, 3MF ceiling tiles metal above
70. Room 24 Carpeted concrete floor, solid walls, 3MF ceiling tiles metal above
71. Room 25 Carpeted concrete floor, solid walls, 3MF ceiling tiles metal above
72. Room 26 Carpeted concrete floor, solid walls, 3MF ceiling tiles metal above
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 382 of 386
.......................................................................................
Area Description of Materials
73. Room 23 Carpeted concrete floor, solid walls, 3MF ceiling tiles metal above
74. Corridor outside Room 23 Vinyl concrete floor, solid walls, 3MF ceiling tiles metal above
75. Shop Carpeted and vinyl concrete floor, solid walls, plastic and 3MF ceiling tiles metal above
76. Shop Store Vinyl concrete floor, solid walls, 3MF ceiling tiles concrete above
77. Room15 Games room Vinyl concrete floor, solid walls, 3MF ceiling tiles concrete above
78. Room 22 Female WC Tiled floor, solid walls, 3MF ceiling tiles concrete above
79. Room 4 Dining room/servery Vinyl concrete floor, 3MF ceiling tiles metal above, solid walls
80. Room 69 Smoking Lounge Vinyl concrete floor, solid walls, 3MF suspended ceiling tiles metal above
81. Room 70 Non Smoking Lounge
Vinyl concrete floor, solid walls, 3MF suspended ceiling tiles metal above
82. Room 18 Kitchen Vinyl concrete floor, solid walls, plasterboard suspended ceiling tiles metal above
83. Room 19 Kitchen Manager Vinyl concrete floor, solid walls, plasterboard suspended ceiling tiles metal above
84. Room 20 Store Vinyl concrete floor, solid walls, plasterboard suspended ceiling tiles metal above
85. Kitchen freezers Vinyl concrete floor, solid walls, plasterboard suspended ceiling tiles metal above
86. Room 36 Quadrant Office Vinyl concrete floor, solid walls, 3MF suspended ceiling tiles metal above
87. Room 75 Vinyl concrete floor, solid walls, 3MF suspended ceiling tiles metal above
88. Room 76 Vinyl concrete floor, solid walls, 3MF suspended ceiling tiles metal above
89. Room 21 Carpeted concrete floor, solid walls, 3MF suspended ceiling tiles concrete above
90. Room 5 Carpeted concrete floor, solid walls, 3MF ceiling tiles metal above
91. Room 6 Carpeted concrete floor, solid walls, 3MF ceiling tiles metal above
92. Room 7 Carpeted concrete floor, solid walls, 3MF ceiling tiles metal above
93. Room 8 Carpeted concrete floor, solid walls, 3MF ceiling tiles metal above
94. Room 9 Carpeted concrete floor, solid walls, 3MF ceiling tiles metal above
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 383 of 386
.......................................................................................
Area Description of Materials
2nd Floor Mezzanine Floor
2M-001. Vehicle Exhaust Duct - South (Lower)
Concrete floor, concrete/metal access hatch. Concrete walls, metal exhaust grilles to loading bay area and to plenum chamber. Metal access ladders. Insulating board ceiling.
2M-002. Vehicle Exhaust Duct - North West (Upper)
Concrete floor, concrete/metal access hatch. Concrete walls, metal exhaust grilles to loading bay area and to plenum chamber. Insulating board ceiling.
2M-003. Vehicle Exhaust Duct - North (Upper)
Concrete floor, concrete/metal access hatch. Concrete walls, metal exhaust grilles to loading bay area and to plenum chamber. Insulating board ceiling.
2M-004. Vehicle Exhaust Duct - East (Lower)
Concrete floor, concrete/metal access hatch. Concrete walls, metal exhaust grilles to loading bay area and to plenum chamber. Metal access ladders. Insulating board ceiling.
3rd Floor Mezzanine Floor
1. North Lift Lobby Hessian-backed vinyl on concrete floor. Plastered concrete walls, metal radiator . Fibreboard suspended ceiling, concrete above. Vicuclad beam cladding.
2. North Engineers Riser
Hessian-backed vinyl on concrete floor. Breezeblock walls, metal shelving, HV cables. Concrete ceiling with timber and metal panels, vicuclad to steelwork.
3. North Locker Room Quarry tiles on solid floor. Concrete and plastered block walls, timber doors, timber riser panels. Plasterboard suspended ceiling, concrete above with timber shuttering and vicuclad beam cladding, MMMF insulation to pipework.
4. North Lockers Riser Concrete, metal and timber floor. Breezeblock walls, MMMF insulation to pipework, plastic waste pipes. Concrete ceiling with timber and metal panels, vicuclad to steelwork.
5. Conveyor gallery Vinyl floor tiles on concrete with rebar. AIB wall cladding panels, vicuclad beam cladding, concrete columns . Concrete ceiling with steel shuttering panels where previous openings have been backfilled.
6. East Stamp Store Hessian-backed vinyl on concrete floor. Plastered solid walls, plasterboard wall, timber door. Plasterboard suspended ceiling, concrete above.
7. East Male WC Quarry tiles on concrete floor. Timber riser panels, plastic soil pipes, MMMF insulation to pipework, ceramic urinal cisterns, hard rubber WC cisterns, timber doors. Plasterboard suspended ceiling tiles, concrete above, supalux shuttering to pipework riser. Fibreglass insulation to pipework in ceiling void.
8. South East Male WC
Quarry tile floor on solid. Timber riser panels, plastic soil pipes, MMMF insulation to pipework, metal sluice, timber doors. Fibreboard suspended ceiling tiles, concrete above.
9. South East Female WC
Hessian-backed vinyl flooring on concrete. MMMF insulation to pipework, plastic cisterns, timber doors. Plasterboard suspended ceiling tiles, concrete above.
10. South West Female WC
Quarry tile floor on solid. Timber riser panels, plastic soil pipes, MMMF insulation to pipework, timber door. Fibreboard suspended ceiling tiles, concrete above.
11. South West Office Carpet tiles on quarry tile floor on solid. Timber riser panels, plastic soil pipes, MMMF
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 384 of 386
.......................................................................................
insulation to pipework, timber door, timber inspection hatch to fire riser. Plasterboard suspended ceiling tiles, concrete above.
12. South West Lobby Hessian-backed vinyl on concrete floor. Solid walls, timber doors, timber and glass hatch to fire riser. Plasterboard ceiling tiles, concrete above.
16. Throughout level 3 Mezz
Not applicable
17. Room 17 above G6 lift
Concrete ceiling, insulating board walls, vinyl tiled concrete floor
34. Room 18 Mezz plant room
Concrete floor, solid walls, concrete ceiling
4th Floor Mezzanine Floor
1. Main lobby Carpeted concrete floor, solid walls, 3MF ceiling tiles concrete above.
2. Main riser Concrete floor, block walls, concrete ceiling
3. Old server room Timber and concrete floor, solid walls, 3MF ceiling tiles concrete above
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 385 of 386
.......................................................................................
Area Description of Materials
4. Kitchen Lobby Carpeted concrete floor, solid walls, 3MF ceiling tiles concrete above
5. Kitchen Vinyl concrete floor, solid walls, 3MF ceiling tiles concrete above
6. Toilets Quarry tile floor. Plaster and block walls, timber panels. Fibreboard suspended ceiling, concrete above with modern services.
7. Mezzanine offices North Concrete ceiling, 3MF ceiling tiles, block walls, plasterboard and timber walls. Vicuclad cladding to beams RSJs. Carpet, vinyl tiles and concrete. 3MF vent duct insulation.
8. UPS Room Concrete ceiling, block walls. Vicuclad cladding to beams RSJs, supalux shuttering to soil pipes. Concrete floor.
4m West Tower. 4mw1 - 4mw3
Conrete upper, plasterboard ceiling tiles. Block walls, quarry tile floor with vinyl. Porcelain plastic cisterns, 3MF pipe insulation.
4m South West Tower. 4msw1-4msw3
Concrete upper with plasterboard ceiling tiles. Block walls, quarry tile & vinyl onto concrete. 3MF pipe insulation plastic & porcelain cisterns.
4m South East Tower. 4mse1- 4mse 3a,b & c
Concrete upper with plasterboard ceiling tiles. Concrete floor, quarry tiles & vinyl floor covering. Porcelain and plastic cisterns. 3MF pipe insulation.
Lift Shaft
1. G4 (LPG 009) Concrete roof and floor with brick walls. Metal doors and aprons.
2. G2 (LPG 007) Brick and concrete construction were viewed. Metal doors and surrounds.
3. G1 (LPG 006) Brick, block and concrete construction. Fibreboard within wall expansion joints. Metal doors and surrounds, no access behind unsafe. No access below level 2 (Tunnel Area)
4. P1-3 Passenger Lift Block walls with IB wall dividers. Concrete ceiling and floor. Metal doors and aprons.
Liverpool John Moores UniversityRefurbishment & Demolition Surveys / J004560 Page 386 of 386
.......................................................................................