Listing Constructional Data Report (CDR)
Report Number 3188316CHI-006 Original Issued: 11-Feb-2011 Revised: 26-Apr-2013
Standard(s)
Applicant Manufacturer
Address Address
Country CountryContact ContactPhone PhoneFAX FAX
Email Email(417) [email protected]
(417) [email protected]
Cardinal Scale Mfg. Co.
Standard for Safety for Information Technology Equipment - Safety - Part 1: General Requirements, ANSI/UL 60950-1/CSA C22.2 No. 60950-1, Second Edition, Dated 03/27/07, Revised 12/19/2011.
1.0 Reference and Address
203 East DaughertyWebb City, MO 64870
(417) 673-4631 (417) 673-4631
203 East DaughertyWebb City, MO 64870
Mr. Steve Langford Mr. Steve LangfordUSA USA
Cardinal Scale Mfg. Co.
Page 1 of 47
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 2 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
Product Brand name
Models
Model Similarity
825, 758C, 750, 225, 215, 210, 205, 204, 200, 180, MV1 (MedVue)
The models 825, 225, 215, 210, 205, 204, and 180 are all digital weight indicators, housed in stainless steel enclosures of different dimensions.The models 750, 758C, 204, and MV1 (MedVue) are all digital weight indicators, housed in painted steel enclosures, powered by external AC adapters.The model 200 is housed in an aluminum panel mount enclosure and is powered by an external AC adapter.The models 825, 225, 215, 210, and 205 are powered by an internal universal (90-254VAC) input AC to DC converter power supply modules. The models 750, 758C, 204, and 215 can all be powered by primary or secondary batteries.The models 750, 204, and 215 are equipped with integral battery chargers for use with secondary batteries. The 785C cannot recharge batteries.Models 825, 225, 215, 210, and 205 are outdoor use NEMA 3R.Models 758C, 750, 204, 200, 180 are indoor use only.The models 825, 225, 215, 204, 750, and 758C have LCD displays.The models 200, 205, 210, and 180 have LED displays.
825: 100 to 240 VAC 50/60Hz, 1A Max758C: 12 VDC Input, Powered by 115 VAC 50/60Hz, 12 VDC 300 mA Adapter or 6 “C” cell Alkaline, Ni-Cad or NiMH batteries750: 12 VDC Input, Powered by 100 to 240 VAC 50/60Hz, 12Vdc, 1A Adapter or 6 “AA”
2.0 Product Description
Weight IndicatorsCardinal DETECTO
Description
The products covered by this report are weight indicating equipment, intended for indoor use or conditions where extreme light or wetting will occur, as outlined below. The units are intended to be used with end-user provided scale and interfaces with the scale. The units may be used on tabletop or mounted to a wall. AC powered units are provided with a permanently connected cord and plug for connection to the source and may also be provided with provisions for battery operation (depending on model). DC powered units are provided with a detachable Listed Class 2 or L.P.S. AC supply and provisions for battery operation.
Ratings
Other Ratings Models 825, 225, 215, 210, and 205 are outdoor use NEMA 3R
750: 12 VDC Input, Powered by 100 to 240 VAC 50/60Hz, 12Vdc, 1A Adapter or 6 “AA” Alkaline, Ni-Cad or NiMH batteries225: 100 to 240 VAC 50/60Hz, 0.4A Max.215: 100 to 240 VAC 50/60Hz, 0.4A Max., 10 “AA” NiMH batteries210: 100 to 240 VAC 50/60Hz, 0.4A Max.205: 100 to 240 VAC 50/60Hz, 0.4A Max.204: 12 VDC Input, Powered by 115 VAC 50/60Hz, 12 VDC 300mA Adapter or (6) C cell batteries, Alkaline, Ni-Cad or NiMH200: 15 VDC Input, Powered by 100 to 240 VAC 50/60Hz 15 VDC 1A Adapter 180: 12 VDC Input, Powered by 100 to 240 VAC 50/60Hz 12 VDC 1A Adapter MV1 (MedVue): 12 VDC, 1.0A Input; Powered by 100-240 VAC 50/60 Hz Adapter with a 12 VDC, 1.25A Output; or 6 “AA” cell Alkaline, Ni-Cad or NiMH Batteries
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 3 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
Photo 1 - Model 825 (Front)
3.0 Product Photographs
1
3
2
1
3
2
3334
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 4 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
3.0 Product Photographs
Photo 2 - Model 825 (Internal)
Photo 3 - Model 825 (Power supply with cover remove d)
5
6
7
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 5 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
3.0 Product Photographs
Photo 4 - Model 215 (Front)
Photo 5 - Model 215 (Internal)
8
13
10
11
12
13
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 6 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
3.0 Product Photographs
Photo 6 - Model 215 (Power Supply with cover remove d)
Photo 7 - Model 758C (Front)
9
14
15
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 7 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
3.0 Product Photographs
Photo 8 - Power Adapter (optional)
Photo 9 - Model 758C (Rear with battery cover remov ed)
16
17
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 8 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
3.0 Product Photographs
Photo 10 - Model 758C (Internal)
Photo 11 - Model 750 (Rear with battery cover remov ed)
19
18
19
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 9 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
3.0 Product PhotographsPhoto 11 - Model 750 (Rear with battery cover remov ed)
Photo 11A - Model 750 (Alternate SMT version of PWB )
20 20
2020 2020
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 10 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
3.0 Product Photographs
Photo 12 - Model 204 (Rear with battery cover remov ed)
Photo 13 - Model 204 (Internal)
21
25
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 11 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
3.0 Product PhotographsPhoto 14 - Power Adapter (optional)
Photo 15 - Model 200 (Rear)
22
23
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 12 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
3.0 Product PhotographsPhoto 16 - Power Adapter (optional)
Photo 17 - Front View of Model MV1 (MedVue)
24
15
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 13 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
3.0 Product PhotographsPhoto 18 - Rear View of Model MV1 (MedVue)
15
Photo 19 - PWB of Model MV1 (MedVue)
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 14 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
3.0 Product PhotographsPhoto 20 - Close Up of Power Supply Provided for Mo del MV1 (MedVue)
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 15 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
Photo #
Item no.1
NameManufacturer/ trademark2 Type / model2
Technical data and securement means
Mark(s) of conformity
3
1 1 Enclosure Various Various
(Model 825) Stainless steel, min. 16GA(1.6mm) thick. Rear panel secured to front by 18 screws. Measures 305mm W x 247mm H x 95mm D
NR
1 2Power Supply Cord
Various Various
(Models 205, 210, 215, 225 825) Non-detachable cord set rated 300 VAC, 18/3 AWG, SVT (Suitable for wet location) with a molded-on NEMA 5-15P
UL, CSA
1 3 Strain-Relief Various (Typical Hubbel)
Various (Typical SEC50BA)
(Models 205, 210, 215, 225 825) Polymeric liquid-tight, for cord dia. 0.17 - 0.47", conduit size 0.5"
UL, cUL
1 4 Strain-ReliefVarious (Typical Sealcon/Hummel)
Various (Typical CD09AA-BR)
(Model 825) Metal, for cord dia. 0.16 - 0.31, conduit size
UL, CSA
2, 11, 19
5 PWB Various Various (all models) Rated V-0, 105°C UR, CSA
2 6 Gasket Rogers Corporation
HT-6360(Models 205, 210, 215, 225, 825) 105°C, V-0
UR
3 7 Power Supply Skynet SNP-9541
(Model 825) Rated input: 100-240Vac, 0.5A, 47-63Hz; output: 5V/3A; 12V/2A; -12V/.3A, 40W, SELV non-hazardous energy
UR, cUR
(Model 205, 210 & 215, 225 ) Stainless steel, min. 16GA
4.0 Critical Components
4 8 Enclosure Various Various
Stainless steel, min. 16GA (1.6mm) thick. Rear panel secured to front by screws. Measures 233mm W x 191mm H x 79mm D. Model 225 Measures 276mm W x 208mm H x 79mm D)
NR
6 9 Power Supply Cincon CFM2003S
(Models 215, 225, 210, 205) Rated input: 100-240Vac, 0.5A, 47-63Hz; output: 15Vdc, 1.4A, maximum 22W, SELV non-hazardous energy
UL, CSA
5 10 Terminal Block Blockmaster PA10DS-12(Models 215, 225, 210, 205) Rated 600V, 30A; Suitable for 12-22 AWG, 8mm pitch, V-2, 105°C
UR, cUR
5 11 Line Filter Corcom 1VB3(Models 215, 225, 210, 205) Rated 120/250Vac, 1A, 50-60Hz; Suitable for up to 40°C ambient
UR, cUR
5 12 Varistor (optional) Epcos S14K300(Models 215, 225, 210, 205) Rated 300Vac, 385Vdc, 4.5kA current surge, V-0, 85°C
UR, CSA
5 13 Batteries Various Various(Model 215-optional) (10 provided) "AA" or NiMH, 2300mAh batteries.
NR
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 16 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
Photo #
Item no.1
NameManufacturer/ trademark2 Type / model2
Technical data and securement means
Mark(s) of conformity
3
4.0 Critical Components
7 14 Enclosure Various Various
(Model 180, 758C, 750) Painted steel, min. 20GA (0.9mm) thick. Rear panel secured to front by screws. Measures 204mm W x 168mm H x 54mm D
NR
7, 17, 18
15Plastic Enclosure Endcap
CHEIL INDUSTRIES/ Samsung
Starex VH-0850 (Model 180, 758C, 750, Model MV1 [MedVue]) 60°C, V-0, 1.8mm thick
cURus
8 16Power Adapter (optional)
Various Various
(Model 180, 758C and 750) Direct-plug type; rated input: 100-240Vac, 0.3A, 47-63 Hz; output: 12Vdc, 1A, SELV non-hazardous energy
UL, cUL
8 17 Batteries Various Various(Model 750, 758C - optional) (6 provided) "C" Alkaline, Ni-Cad or NiMH
NR
8 18 BatteryVarious (Typical Spectrum Brands)
Various (BR1225T2-B)
(Model 180, 758C, 750) Rated 3V, 50uAh. Secured to PWB by tabs.
UR
10 19 Diode D1,D10IN5817 or equivalent
Various (Model 758C) 20V 1A NR
11 20 FET Q2,Q8SI2303 or equivalent
Various (Model 750) 30V, 1A NR
12 21 Enclosure Various Various
(Model 204) Stainless steel, min. 20GA (0.95mm) thick. Rear panel secured to front by screws. Measures 198mm W x 41mm H x 165mm D
NR
GT-341-12-GlobTek
GT-341-12-300D
Various Various
15 23 Enclosure Various Various
(Model 200) Aluminum, min. 1mm thick. Rear panel secured to front by screws. Measures 135mm W x 66.6mm H x 232mm D
NR
16 24 Power Adapter Various Various
(Model 200) Direct-plug type; rated input: 100-240Vac, 0.3A, 47-63 Hz; output: 15Vdc, 1A, 15W, SELV non-hazardous energy
UL, cUL
12 25 Label Various Various (All Models) Labeling system, 60ºC minimum, indoor/outdoor use on metal
cURus
Power Supply (item 16 may optionally be substituted for this power supply)
221
(Model 204) Rated input: 120Vac, 60Hz 10W; output: 12Vdc, 300mA, Class 2 or equivalent 12V Class 2 or SELV Non-hazardous energy, output adaptor.
UL, cUL
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 17 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
Photo #
Item no.1
NameManufacturer/ trademark2 Type / model2
Technical data and securement means
Mark(s) of conformity
3
4.0 Critical Components
17, 18
26 Enclosure Various Various
(Model MV1 [MedVue]) Painted steel, min. 20GA (0.95mm) thick. Rear panel secured to front by screws. Measures 171.45mm W x 193.80mm H x 44.45mm D
NR
20 27 Power Supply GlobTek, Inc
GTM21089-1512-T3 (TR9CE1250LCP-Y-MED)
(Model MV1 [MedVue]) Input rated 100-240Vac, 0.5A, 50-60Hz. Output rated 12Vdc, 1.25A.
cURus
NOTES:
3) Indicates specific marks to be verified, which assures the agreed level of surveillance for the component. "NR" - indicates Unlisted and only visual examination is necessary. "See 5.0" indicates Unlisted components or assemblies to be evaluated periodically refer to section 5.0 for details.
2) “Various“ means any type, from any manufacturer that complies with the "Technical data and securement means" and meets the "Mark(s) of conformity" can be used.
1) Not all item numbers are indicated (called out) in the photos, as their location is obvious.
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 18 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
No Unlisted CEC components are used in this report.
5.0 Critical Unlisted CEC Components
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 19 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
1. Spacing - In primary circuits, 3.2 mm minimum spacing are maintained through air and over surfaces of insulating material between current-carrying parts of opposite polarity of terminal block.
Listed Component - A component part, which has been previously Listed or Certified by an accredited Certification Organization with no restrictions and is used in the intended application within its ratings.
Critical Features/Components - An essential part, material, subassembly, system, software, or accessory of a product that has a direct bearing on the product’s conformance to applicable requirements of the product standard.Construction Details - For specific construction details, reference should be made to the photographs and descriptions. All dimensions are approximate unless specified as exact or within a tolerance. In addition to the specific construction details described in this Report, the following general requirements also apply.
Recognized Component - A component part, which has been previously evaluated by an accredited certification body with restrictions and must be evaluated as part of the basic product considering the restrictions as specified by the Conditions of Acceptability.
6.0 Critical Features
Unlisted Component - A part that has not been previously evaluated to the appropriate designated component standard. It may also be a Listed or Recognized component that is being used outside of its evaluated Listing or component recognition.
Pollution Degree 1 & 2
Creepage (in/mm)
Clearance (in/mm)
Working Volts
Basic/Supplementary Insulation ≤ 71
72 – 210 420
(1.0) (1.0) (3.2)
(2.0) (2.0) (3.2)
2. Mechanical Assembly - Components such as switches, fuse holders, connectors, wiring terminals and display lamps are mounted and prevented from shifting or rotating by the use of lock washers, star washers, or other mounting format that prevents turning of the component.
3. Corrosion Protection - All ferrous metal parts are protected against corrosion by painting, plating or the equivalent.
4. Accessibility of Live Parts - All uninsulated live parts in primary circuitry are housed within a metal and non-metallic enclosure constructed with no openings other than those specifically described in Section 4.
5. Grounding - All models provided with Non-Detachable AC Mains supply cord terminated with a NEMA 5-15 plug are grounded. All exposed dead-metal parts and all dead-metal parts within the enclosure that are exposed are connected to the grounding lead of the power supply cord. Models provided with AC Adaptors are not grounded.
6. Internal Wiring - Internal wiring is routed away from sharp or moving parts. Internal wiring leads terminating in soldered connections are made mechanically secure prior to soldering. Recognized Component separable (quick disconnect) connectors of the positive detent type, closed loop connectors, or other types specifically described in the text of this report are also acceptable as internal wiring terminals. At points where internal wiring passes through metal walls or partitions, the wiring insulation is protected against abrasion or damage by plastic bushings or grommets. All wiring is in primary are minimum 18 AWG, with a minimum rating of 300V, 75°C. All wiring in secondary are minimum 26 AWG, with a minimum rating of 300V, 60°C.
Pollution Degree 1 & 2
Creepage (in/mm)
Clearance (in/mm)
Working Volts
Basic/Supplementary Insulation ≤ 71
72 – 210 420
(1.0) (1.0) (3.2)
(2.0) (2.0) (3.2)
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 20 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
6.0 Critical Features 7. Markings - The product is marked on as labeling system as described in item no. 25 of Section 4.0. See
Illustration 3 and additionally with: manufacturer's name, brand name, model number, date of manufacturer, electrical ratings.
8. Cautionary Markings - The following are required: See item 7 above.9. Installation, Operating and Safety Instructions - Instructions for installation and use of this product are
provided by the manufacturer. Refer to Illustration No(s). 4-19 for details.
The following instructions in English and French are required: "CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS
and
ATTENTION: Risque d'explosion si la batterie est remplacée par un type INCORRECT. Eliminer selon les piles usagées à LES INSTRUCTIONS
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 21 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
Illustration 1 - Schematic of model 750 showing Q2, Q8, Q9, D3 and D5
Illustration 2 - Schematic of model 758 showing D1 and D10
7.0 Illustrations
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 22 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
7.0 Illustrations
Illustration 3 - Representative Labels
Representative - shows manufacturer's name and model number designation
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 23 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
7.0 Illustrations
Illustration 4 - Instructions model 825
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 24 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
7.0 IllustrationsIllustration 5 - Instructions model 825
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 25 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
7.0 IllustrationsIllustration 6 - Instructions model 825
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 26 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
7.0 IllustrationsIllustration 7 - Instructions model 210, 215
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 27 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
7.0 IllustrationsIllustration 8 - Instructions model 210, 215
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 28 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
7.0 IllustrationsIllustration 9 - Instructions model 205
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 29 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
7.0 IllustrationsIllustration 10 - Instructions model 205
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 30 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
7.0 IllustrationsIllustration 11 - Instructions model 225
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 31 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
7.0 IllustrationsIllustration 12 - Instructions model 225
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 32 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
7.0 IllustrationsIllustration 13 - Instructions model 225
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 33 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
7.0 IllustrationsIllustration 5 - Instructions model 758
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 34 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
7.0 IllustrationsIllustration 14 - Instructions model 758C
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 35 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
7.0 IllustrationsIllustration 15 - Instructions model 750
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 36 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
7.0 IllustrationsIllustration 16 - Instructions model 750
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 37 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
7.0 IllustrationsIllustration 17 - Instructions model 204
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 38 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
7.0 IllustrationsIllustration 18 - Instructions model 204
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 39 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
7.0 IllustrationsIllustration 19 - Model MV1 (MedVue) Owner's Manual (8555-M512-O1 Rev A 03/13)
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 40 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
Evaluation Period Project No. 3188316
Sample Rec. Date8/24/2009, 9/10, 1/11,11
Condition Prototype Sample ID.
CHI0908241335-001 - 007, CHI1101121057-001
Test LocationTest Procedure
ANSI/UL 60950-1-2007 CAN/CSA C22.2 No 60950-1-07 Clause
ANSI/UL 50E Clause
1.6.2 N/A2.6.3 N/A2.9.2 N/A3.2.6 N/A4.2.4 N/A4.2.5 N/A4.2.6 N/A4.2.7 N/A
4.2.10 N/A4.3.8 N/A4.5.1 N/A5.1 N/A5.2 N/A5.3 N/AN/A 8.3
Evaluation Period Project No. 3141307SVN
Temperature rise testLeakage Current TestElectric Strength Test
Battery Test
Rain Test
8.0 Test Summary
Intertek, 545 East Algonquin Road, Suite F, Arlington Heights, IL, 60563 USATesting Lab
Test Description
09/02/09 - 09/10/10, 1/17/11
Ground Impedance
Determination of the result includes consideration of measurement uncertainty from the test equipment and methods. The product was tested as indicated below with results in conformance to the relevant test criteria.The following tests were performed:
Input Test
Mounting Test
Mechanical Strength –Steady force test, 250 NMechanical Strength – Impact testMechanical Strength – Drop test
3/12/2012
Strain ReliefHumidity Condition Test
Abnormal Operations and Fault Conditions Test
Stress Relief Test
Evaluation Period Project No. 3141307SVN
Evaluation Period Project No. G101148859Sample Rec. Date 4/17/2013 Condition Prototype Sample ID. 04172013022030Test LocationTest Procedure
ANSI/UL 60950-1-2007 CAN/CSA C22.2 No 60950-1-07 Clause
1.6.22.2.22.2.32.5
4.5.25.2, 5.3.4(b)
5.3.7
04/22/2013 - 04/26/2013
Intertek, 545 East Algonquin Road, Suite F, Arlington Heights, IL, 60563 USATesting Lab
Determination of the result includes consideration of measurement uncertainty from the test equipment and methods. The product was tested as indicated below with results in conformance to the relevant test criteria.The following tests were performed:
Test DescriptionInput TestSELV Measurement Test under Normal ConditionsSELV Measurement Test under Fault ConditionsLimited Power Source TestTemperature Rise TestElectric Strength Test for Functional Insulation
Due to previous testing performed and reported above no additional testing was necessary for UL 60950-1/CSAC22.2 No. 60950-1, Second Edition, Dated 03/27/07, Revised 12/19/2012.
3/12/2012
Fault Tests
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 41 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
8.0 Test Summary
Completed by: Reviewed by:Title: Title:
Signature: Signature:
8.1 Signatures
Brian Siuta Syed RizviProject Engineer Engineering Manager
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 42 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
BASIC LISTEE
Address
CountryProduct
MULTIPLE LISTEE 1AddressCountry
Brand Name
ASSOCIATED MANUFACTURER
AddressCountry
BASIC LISTEE MODELS
MULTIPLE LISTEE 2AddressCountry
Brand Name
ASSOCIATED MANUFACTURER
AddressCountry
BASIC LISTEE MODELS
MULTIPLE LISTEE 3AddressCountry
Brand Name
ASSOCIATED MANUFACTURER
AddressCountry
BASIC LISTEE MODELS
None
MULTIPLE LISTEE 3 MODELS
MULTIPLE LISTEE 2 MODELS
None
MULTIPLE LISTEE 1 MODELS
USAWeight Indicators
None
9.0 Correlation Page For Multiple ListingsThe following products, which are identical to those identified in this report except for model number and Listeename, are authorized to bear the ETL label under provisions of the Intertek Multiple Listing Program.
Cardinal Scale Mfg. Co.203 East DaughertyWebb City, MO 64870
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 43 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
10.0 General InformationThe Applicant and Manufacturer have agreed to produce, test and label ETL Listed products in accordance with the requirements of this Report. The Manufacturer has also agreed to notify Intertek and to request authorization prior to using alternate parts, components or materials.
COMPONENTSComponents used shall be those itemized in this Intertek report covering the product, including any amendments and/or revisions.
LISTING MARKThe ETL Listing mark applied to the products shall either be separable in form, such as labels purchased from Intertek, or on a product nameplate or other media only as specifically authorized by Intertek. Use of the mark is subject to the control of Intertek.
The mark must include the following four items:
1) applicable country identifiers "US" and/or "C" or "US", "C" and "EU" 2) the word "Listed" or "Classified" or "Recognized Component" (whichever is appropriate)3) a control number issued by Intertek 4) a product descriptor that identifies the standards used for certification. Example:
For US standards , the words, “Conforms to” shall appear with the standard number along with the word, “Standard” or “Std.” Example: “Conforms to ANSI/UL Std. XX.”
For Canadian standards , the words “Certified to CAN/CSA Standard CXX No. XX.” shall be used, or abbreviated, “Cert. to CAN/CSA Std. CXX No. XX.”
Can be used together when both standards are used.
Note: A facsimile must be submitted to Intertek, At tn: Follow-up Services for approval prior to use. The facsimile need not have a control number. A control number will be issued after signed Certification Agreements have been received by the Follow-up Services office, approval of the facsimile of your proposed Listing Mark, satisfactory completion of the Listing Report, and scheduling of a factory assessment in your facility.
MANUFACTURING AND PRODUCTION TESTSManufacturing and Production Tests shall be performed as required in this Report.
FOLLOW‑UP SERVICEPeriodic unannounced audits of the manufacturing facility (and any locations authorized to apply the mark) shall be scheduled by Intertek. An audit report shall be issued after each visit. Special attention will be given to the following:
1. Conformance of the manufactured product to the descriptions in this Report.2. Conformance of the use of the ETL mark with the requirements of this Report and the Certification Agreement.3. Manufacturing changes.4. Performance of specified Manufacturing and Production Tests.
In the event that the Intertek representative identifies non-conformance(s) to any provision of this Report, the Applicant shall take one or more of the following actions:
1. Correct the non-conformance.2. Remove the ETL Mark from non-conforming product.3. Contact the issuing product safety evaluation center for instructions.
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 44 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
10.1 Evaluation of Unlisted Components
Note to Intertek Follow Up Inspector: The Component Evaluation Center, CEC, will notify you in writing when these components must be selected and sent to the CEC for re-evaluation
Ship the samples to:Intertek Testing Services NA Inc.ETL Component Evaluation Center45000 Helm Street, Suite 150Plymouth Twp., MI 48170 USAAttn: Component Evaluation CenterSample Disposition: Due to the destructive nature of the testing, all samples will be discarded at the conclusion of testing unless, the manufacturer specifically requests the return of the samples. The request for return must accompany the initial component shipment.�
Because Unlisted Components are uncontrolled, and they do not fall under a third party follow up program, Intertek may require these components to be tested and/or evaluated at least once annually, more often for certain components, as part of the independent certification process. The Unlisted Components in Section 5.0 require testing and/or evaluation as indicated.
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 45 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
Product Test Voltage Test TimeAll models provided with Non-Detachable AC Mains supply cord terminated with a NEMA 5-15 plug.
1000V 60 s
MOVs (item 12) if used may be removed on Models 205, 210, 215, and 225 prior to conducting test.
or
1200V 1 s
Dielectric Voltage Withstand Test, Grounding Continuity Test
11.0 Manufacturing and Production TestsThe manufacturer agrees to conduct the following Manufacturing and Production Tests as specified:
Required Tests
The test equipment shall incorporate a voltmeter in the output circuit to indicate directly the applied test potential if the rated output of the test equipment is less than 500VA.If the rated output of the test equipment is 500VA or more, the applied test potential may be indicated by either: 1 - a voltmeter in the primary circuit; 2 - a selector switch marked to indicate the test potential; or 3 - a marking in a readily visible location to indicate the test potential for test equipment having a single test potential output. In cases 2 and 3, the test equipment shall include a lamp or other visual means to indicate that the test potential is present at the test equipment output. All test equipment shall be maintained in current calibration.
Products Requiring Dielectric Voltage Withstand Tes t:
The test voltage specified below shall be applied between primary circuits and accessible dead-metal parts. The test voltage may be gradually increased to the specified value but must be maintained at the specified value for one second or one minute as required.
Test EquipmentThe test equipment shall incorporate a transformer with an essentially sinusoidal output, a means to indicate the applied test potential, and an audible and/or visual indicator of dielectric breakdown.
11.1 Dielectric Voltage Withstand TestMethodOne hundred percent of production of the products covered by this Report shall be subjected to a routine production line dielectric withstand test.
The test shall be conducted on products, which are fully assembled. Prior to applying the test potential, all switches, contractors, relays, etc., should be closed so that all primary circuits are energized by the test potential. If all primary circuits cannot be tested at one time, then separate applications of the test potential shall be made.
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 46 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
All models provided with Non-Detachable AC Mains supply cord terminated with a NEMA 5-15 plug.
11.2 Grounding Continuity Test
Products Requiring Grounding Continuity Test:
If all accessible dead metal is connected, only a single test need be performed. A visual or audible device(ohmmeter, buzzer, etc.) may be used to indicate grounding continuity.
Each product listed below shall be subjected to a test to determine that there is continuity between accessibledead-metal parts of the product and the grounding pin or blade of the attachment plug.
Method
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 3188316CHI-006Cardinal Scale Mfg. Co.
Page 47 of 47 Issued: 11-Feb-2011Revised: 26-Apr-2013
Date/ Project Handler/Proj # Site ID Reviewer
16-Aug-2011F. Saliga
3 11A Added New Photo of SMT PWB
G100479094-CHI
S. Rizvi
3-Oct-2011F. Saliga
4 12 Item 12 was made Optional
G100479094-CHI
S. Rizvi 11Clarified products requiring Dielectric Voltage Withstand test as "All models provided with Non-Detachable AC Mains supply cord terminated with a NEMA 5-15 plug."
4 22Added (item 16 may be optionally substituted for this power supply), various, various and added "or equivalent 12V Class 2 or SELV Non-hazardous energy adaptor" to technical data.
11Clarified products requiring Grounding Continuity test as "All models provided with Non-Detachable AC Mains supply cord terminated with a NEMA 5-15 plug."
7 ILL 1Changed heading to: Illustration 1 - Schematic of model 750 showing Q2, Q8, Q9, D3 and D5
7 ILL 2Changed heading to: Illustration 2 - Schematic of model 758 showing D1 and D10
12-Mar-2012 1 --Administrative change updating standard UL 60950-1/CSA C22.2 No. 60950-1, Second Edition from 03/27/07, to 12/19/2012. Product listed not affected
A. Becerra
12.0 Revision SummaryThe following changes are in compliance with the declaration of Section 8.1:
Section Item Description of Change
8 -- Added test block in section 8
8.1 -- Added new signatures 26-Apr-2013 B. Siuta 2 Added MV1 (MedVue) to model listG101148859-CHI S. Rizvi 2 Added MV1 (MedVue) to model similarity
2 Added MV1 (MedVue) information to ratings3 17 Added Photo 17 - Front View of Model MV1 (MedVue)3 18 Added Photo 18 - Rear View of Model MV1 (MedVue)3 19 Added Photo 19 - PWB of Model MV1 (MedVue)
3 20Photo 20 - Close Up of Power Supply Provided for Model MV1 (MedVue)
4 5 Added photo 19 reference to Item 5
4 15Added photo 17 and 18 reference to Item 15, and Model MV1 (MedVue) reference to technical data
4 26 Added Model MV1 (MedVue) enclosure4 27 Added Model MV1 (MedVue) power supply6 9 Updated Illustration reference from 4-18 to 4-19
7 19Added Illustration 19 - Model MV1 (MedVue) Owner's Manual (8555-M512-O1 Rev A 03/13)
8Added test summary for 04/22/2013 - 04/26/2013 evaluation period
3141307 SVN D. Tobias
ED 16.3.15 (1-Jan-13) Mandatory