Lighting and Illumination Introduction
Electrical lighting Non-Electrical lighting
1. Clean in operation 1. Dirty in operation
2. Easy to control 2. Control is difficult
3. Reliable 3. Non-reliable
4. Steady output 4. Varying output
5. High efficiency 5. Low efficiency
6. Low cost 6. High cost
7. Less hazardous 7. More hazardous
8. Low possibility of fire 8. High possibility of fire
9. e.g. Fluorescent lamp, discharge lamp 9. e.g. Candle, oil lamp, fire
• Definition of Illumination• Color of Object
![Page 3: Lighting Safety Considerations](https://reader031.fdocuments.us/reader031/viewer/2022021923/58ed83871a28ab19298b46a9/html5/thumbnails/3.jpg)
Importance of Lighting Safety Considerations.
o Improper Lighting effect:-
1. Eye irritation
2. Headache
3. Reduction in mental alertness
4. Discomfort
5. Reduction in productivity & quality of work
6. Injury to person
![Page 4: Lighting Safety Considerations](https://reader031.fdocuments.us/reader031/viewer/2022021923/58ed83871a28ab19298b46a9/html5/thumbnails/4.jpg)
Injury Trend Based On Lighting Level
Source: Lighting safety considerations by Mathew F.(IEEE Transactions on Industry Applications)
![Page 5: Lighting Safety Considerations](https://reader031.fdocuments.us/reader031/viewer/2022021923/58ed83871a28ab19298b46a9/html5/thumbnails/5.jpg)
Luminous Flux(Lumens): Total quantity of light energy radiated per second.
Illumination(Lux): Luminous flux received by a surface per unit area of surface.
Lamp efficiency(lm/w): Ratio of luminous flux to power input.
Depreciation factor: Ratio of illumination with clean lamp to illumination under working conditions.
Space to height ratio: Ratio of horizontal spacing between two lamps to the height of the lamp above working plane.
Glare
Shadow
• Terminologies
![Page 6: Lighting Safety Considerations](https://reader031.fdocuments.us/reader031/viewer/2022021923/58ed83871a28ab19298b46a9/html5/thumbnails/6.jpg)
Safety Aspects
Lighting Design:- Adequate lighting, glare & shadows, flickers
Maintenance Issues:- Re-lamping, de-energize, environmental factors
Location and Installation:-
Hazardous Locations:- Flameproof & explosion proof lighting , restricted breathing
Maintenance Ergonomics:- Static load , body postures
IE Rules
![Page 7: Lighting Safety Considerations](https://reader031.fdocuments.us/reader031/viewer/2022021923/58ed83871a28ab19298b46a9/html5/thumbnails/7.jpg)
Adequate Illumination
Over Illumination
Definition
Health Effects:-
1. Headache
2. Fatigue
3. Stress
4. Performance effect
Lighting Design
![Page 8: Lighting Safety Considerations](https://reader031.fdocuments.us/reader031/viewer/2022021923/58ed83871a28ab19298b46a9/html5/thumbnails/8.jpg)
Under illumination
Definition
Health Effects:-
1. Headache
2. Fatigue
3. Stress
4. Performance effect
• Design factors
![Page 9: Lighting Safety Considerations](https://reader031.fdocuments.us/reader031/viewer/2022021923/58ed83871a28ab19298b46a9/html5/thumbnails/9.jpg)
Glare and Shadows
Definition
Solution
Power Quality (Flickers)
Definition
Causes
Solution
![Page 10: Lighting Safety Considerations](https://reader031.fdocuments.us/reader031/viewer/2022021923/58ed83871a28ab19298b46a9/html5/thumbnails/10.jpg)
Design Procedure
1. Identify the requirements
2. Determine the method of lighting
![Page 11: Lighting Safety Considerations](https://reader031.fdocuments.us/reader031/viewer/2022021923/58ed83871a28ab19298b46a9/html5/thumbnails/11.jpg)
3. Select the lighting equipment
4. Calculate the lighting parameters and adjust the design as required
5. Determine the control system
6. Choice of luminaries
7. Inspect the installation upon completion
![Page 12: Lighting Safety Considerations](https://reader031.fdocuments.us/reader031/viewer/2022021923/58ed83871a28ab19298b46a9/html5/thumbnails/12.jpg)
Maintenance Issues Re-lamping
Frequency of re-lamping Improper servicing
![Page 13: Lighting Safety Considerations](https://reader031.fdocuments.us/reader031/viewer/2022021923/58ed83871a28ab19298b46a9/html5/thumbnails/13.jpg)
De-energize
Advantages:-
• Quick removal
• Safe and quick replacement
• Eliminating shock and burn hazards
![Page 14: Lighting Safety Considerations](https://reader031.fdocuments.us/reader031/viewer/2022021923/58ed83871a28ab19298b46a9/html5/thumbnails/14.jpg)
Environmental Factors
A. Corrosion : Alloy of Cu free Al , finishing with epoxy powder.
B. Moisture : Fixture with NEMA 4X rating.
C. Dust: Cone fixtures
LED with heat sink
![Page 15: Lighting Safety Considerations](https://reader031.fdocuments.us/reader031/viewer/2022021923/58ed83871a28ab19298b46a9/html5/thumbnails/15.jpg)
Location and installation
Frequency and accessibility at maintenance site
Space restrictions and temperature relations
![Page 16: Lighting Safety Considerations](https://reader031.fdocuments.us/reader031/viewer/2022021923/58ed83871a28ab19298b46a9/html5/thumbnails/16.jpg)
Maintenance Ergonomics Static Loads Awkward working position
![Page 17: Lighting Safety Considerations](https://reader031.fdocuments.us/reader031/viewer/2022021923/58ed83871a28ab19298b46a9/html5/thumbnails/17.jpg)
Flame proof and Explosion proof Lighting :
o Contain explosion within itself
o Escaping gases released at below ignition temp. of external area
o Heat is released through lens
o Housed in flameproof enclosures
o Made up of Non-metallic materials
Hazardous Locations
![Page 18: Lighting Safety Considerations](https://reader031.fdocuments.us/reader031/viewer/2022021923/58ed83871a28ab19298b46a9/html5/thumbnails/18.jpg)
Restricted Breathing
o Prevent entry of flammable gases
o Done by using external sealing that prevent in and out of air
o External material should bear high temperature
![Page 19: Lighting Safety Considerations](https://reader031.fdocuments.us/reader031/viewer/2022021923/58ed83871a28ab19298b46a9/html5/thumbnails/19.jpg)
Indian Standard Code for Lighting Indian Standard CODE OF PRACTICE FOR INDUSTRIAL
LIGHTING IS : 6665 – 1972
FACTORS INFLUENCING GOOD INDUSTRIAL LIGHTING PRACTICE :
A good industrial lighting should take into account:
a) adequate quantity of illumination, and
b) good quality of illumination.
o A general lighting system should be designed to provide a uniform distribution of light over the entire work area.
![Page 20: Lighting Safety Considerations](https://reader031.fdocuments.us/reader031/viewer/2022021923/58ed83871a28ab19298b46a9/html5/thumbnails/20.jpg)
o In locations where dirt will collect very rapidly on luminaries surfaces and where adequate maintenance is not available, they should maintain periodically.
• Quality of Illumination : To reduce direct glare in industrial areas, the following steps should be taken :
1. Decrease the luminance of light sources or lighting equipment, or both
2. Reduce the area of high luminance causing the glare condition
3. Increase the angle between the glare source and the line of vision
4. Increase the luminance of the area surrounding the glare source and against which it is seen.
![Page 21: Lighting Safety Considerations](https://reader031.fdocuments.us/reader031/viewer/2022021923/58ed83871a28ab19298b46a9/html5/thumbnails/21.jpg)
High reflectance surfaces are generally desirable to provide the recommended luminance relationships and high utilization of light. They also improve the appearance of the work space. It is also desirable that the background is slightly darker than the seeing task.
In uniform illumination, the distribution of light with a maximum and minimum illumination at any point should not be more than one-sixth above or below the average level in the area.
Colour discrimination and colour matching are a part of the work process, the light source selected should have the desired colour rendering properties.
![Page 22: Lighting Safety Considerations](https://reader031.fdocuments.us/reader031/viewer/2022021923/58ed83871a28ab19298b46a9/html5/thumbnails/22.jpg)
Required Illumination Level In Industry
![Page 23: Lighting Safety Considerations](https://reader031.fdocuments.us/reader031/viewer/2022021923/58ed83871a28ab19298b46a9/html5/thumbnails/23.jpg)
Conclusion
Lighting design is not simple and straight forward as one may think. It needs to start safety centered approach.
Safety is affected by the reliability , longevity and maintainability of the designed system.
End users must do their research and should
achieve the best and safest design possible.
![Page 24: Lighting Safety Considerations](https://reader031.fdocuments.us/reader031/viewer/2022021923/58ed83871a28ab19298b46a9/html5/thumbnails/24.jpg)