LIGHTING CONSTRUCTION MANUAL · Major Road BPM Steel Pole / Foundation - U/G Service Pedestrian...
Transcript of LIGHTING CONSTRUCTION MANUAL · Major Road BPM Steel Pole / Foundation - U/G Service Pedestrian...
LIGHTING CONSTRUCTION MANUAL
FLOOD LIGHTING
Go to SECTION INDEX Back to MAIN INDEX
1-9-1-1
1 9 1-1 0E
LIGHTING
10500-A4-1-9-1-1
1-9-2-1
DESCRIPTIONTYPE PAGE TYPE DESCRIPTION PAGE
B 10.12.12
1-9-2-2
1-9-5-1
1-9-4-1
1-9-3-2
1-9-3-1
1-9-7-1
1-9-6-1
1-9-7-2
MINOR ROAD CONSTRUCTION
FLOODLIGHTING INDEX
1-9-8-2
1-9-8-1
1-9-11-1
SLBPM
SLBPM
SLBPM
1-9-11-2
SLWF
SLWF
SLWF
SLWF
SLWF
SLPX
SLPX
SLPX
Major Road BPM Steel Pole / Foundation - U/G Service
Pedestrian Crossing Floodlight Single - Materials
Major Road BPM Steel Pole / Foundation - U/G Service
Pedestrian Crossing Floodlight Single - Construction
Major Road BPM Steel Pole / Foundation - O/H Service
Major Road BPM Steel Pole / Foundation - O/H Service
Pedestrian Crossing Floodlight Single - Construction
Pedestrian Crossing Floodlight Single - Materials
Major Road BPM Steel Pole / Foundation - U/G Service
Pedestrian Crossing Floodlight Type PF3 - Materials
Major Road BPM Steel Pole / Foundation - U/G Service
Pedestrian Crossing Floodlight Type PF3 - Construction
C 08.01.14
D 03.04.18
E 15.08.18
Construction Type Guide - Watchman Floodlight
Construction Type Guide - Pedestrian Crossing
1-9-2-3Construction Type Guide - Pole Bracket
1-9-4-2
Watchman Floodlight Wood Pole - Material
Watchman Floodlight Wood Pole - Construction
Watchman Floodlight Existing O/H Supply
Steel / Concrete Pole - Materials
Watchman Floodlight Existing O/H Supply
Steel / Concrete Pole - Construction
Watchman Floodlight Existing U/G Supply
Steel / Concrete Pole - Materials & Construction
Watchman Floodlight Existing Customer Property
Pole O/H Supply - Materials & Construction
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
01/11/10
EXAMPLE:-
STREETLIGHT
Adetail drawings in this manual.
appears on relevant construction
Type shown within dashed box
B 15.01.13
C 22.11.16
D 06.09.18
SLED PH 1012 F
SUPPLIER IDENTIFIER
GL = Gerard LightingBILLABLE LOAD / LAMP WATTAGE
1012 = 101.2W
LUMINAIRE TYPE
1-9-2-1
1 9 2-1 0E
LIGHTINGFLOODLIGHTING
CONSTRUCTION TYPE GUIDE
PEDESTRIAN CROSSING
10500-A4-1-9-2-1
NIL
NIL
PH = Philips Lighting
SLEDPH1012F = Streetlight pedestrian crossing LED, Philips Lighting 101.2W floodlight
EXAMPLE:-
STREETLIGHT
A
PEDESTRIAN CROSSING CONSTRUCTION TYPE
detail drawings in this manual.
appears on relevant construction
Type shown within dashed box
BILLABLE LOAD / LAMP WATTAGELUMINAIRE TYPE
LED PEDESTRIAN CROSSING CONSTRUCTION TYPE
SLED = Streetlight LED
Floodlight
F = Pedestrian Crossing
SL S250 F
SL = StreetlightS250 = HPS 250W Clear
S400 = HPS 400W Clear
H250 = Metal Halide 250W Clear
H400 = Metal Halide 400W Clear
Floodlight
F = Pedestrian Crossing
SLS250F = Streetlight, HPS 250W, Pedestrian Crossing floodlight
3128 = 312.8W
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
09/08/19
09/08/19
09/08/19
14/10/10E 26.06.19
2029 = 202.9W
EXAMPLE:-
STREETLIGHT
A
WATCHMAN FLOODLIGHT CONSTRUCTION TYPE
detail drawings in this manual.
appears on relevant construction
Type shown within dashed box
B 19.07.18
1-9-2-2
1 9 2-2 0C
LIGHTINGFLOODLIGHTING
CONSTRUCTION TYPE GUIDE
WATCHMAN FLOODLIGHT
10500-A4-1-9-2-2
NIL
NIL
S150 = HPS 150W
S250 = HPS 250W
S400 = HPS 400W
H250 = H 250W
H400 = H 400W
EXAMPLE:-
STREETLIGHT
Adetail drawings in this manual.
appears on relevant construction
Type shown within dashed box
SLED PH 0713 W
SL S150 W
LAMP WATTAGE AND TYPELUMINAIRE TYPE
W = Watchman Floodlight
SW S150 W = Streetlight, HPS 150W, Watchman Floodlight
WATCHMAN LED FLOODLIGHT CONSTRUCTION TYPE
SLED = Streetlight LED
SUPPLIER IDENTIFIER
PH = Philips Lighting
BILLABLE LOAD
0713 = 71.3W
1012 = 101.2W
2029 = 202.9W
LUMINAIRE TYPE
W = Watchman Floodlight
SLED PH 0713 W = Streetlight LED, Philips Lighting, 71.3W, Watchman Floodlight
SL = Streetlight
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
09/08/19
09/08/19
09/08/19
14/10/10
26.06.19C
H150 = H 150W
EXAMPLE:-
STREETLIGHT
Adetail drawings in this manual.
appears on relevant construction
Type shown within dashed box
1-9-2-3
1 9 2-3 0A
LIGHTINGFLOODLIGHTING
CONSTRUCTION TYPE GUIDE
POLE BRACKET
10500-A4-1-9-2-3
NIL
NIL
POLE BRACKETS CONSTRUCTION TYPE
S W 1 ABC
SLED = Streetlight LED
S = Streetlight
POLE TYPE
W = Wood Pole
P = Private
C = Concrete / Steel
NO. OF OUTREACH
1 = Single
CONNECTION
ABC = LV ABC Mains
Cu = Copper Mains
SER = ABC Service
AL = Aluminium Mains
UG = Underground
S W 1 ABC = Streetlight, Wood Pole, Single, LVABC mains
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
26/10/18
B 19.03.13
03.04.18C
14.12.18D 1-9-3-1
1 9 3-1 0E
LIGHTINGFLOODLIGHTING
WATCHMAN FLOODLIGHT
WOOD POLE - MATERIAL
10500-A4-1-9-3-1
NIL
4927-A4-15.1
ASSY DESCRIPTION QTY
914-1
914-2 1
914-3
NOTES:
1.
2.
3.
Watchman floodlight L70
Watchman floodlight L100
Watchman floodlight L200
ASSY DESCRIPTION QTY
803-1
915-1
2804-6
916-1
804-1
804-2
804-7
805-1
805-6
MATERIAL - BRACKET & SUPPLY
Connector I.P.C 25/95mm† main to 6/35mm† tap
6-35mm Aluminium / 4-35mm Copper thru connector
AR
1
AR
AR
Connector tap-off bare aluminium main
Connector tap-off bare copper main
End cap - Push on 25mm† ABC
Conduit PVC flexible - 16mm
e.g. crossarm, arm braces, etc.
are not contacting other pole top hardware
Bracket / Floodlight shall be mounted such that they
66kV = 1800mm
11kV/22kV/33kV = 1200mm
LV = 100mm
Bracket / Floodlight minimum clearance to conductors:-
on regional location - configuration is illustrative only.
Open wire conductor configuration depends
Bracket watchman floodlight to wood pole
803-6 Bracket support to crossarm AR
Saddle (20mm) to wood pole
Bracket LED watchman to wood pole
904-1 1Fuseholder, with 10A HRC, type 10G
ASSY DESCRIPTION QTY
1914-6
914-4
914-5
914-7
914-8
914-9
Watchman floodlight S150
Watchman floodlight S250
Watchman floodlight S400
Watchman floodlight H150
Watchman floodlight H250
Watchman floodlight H400
MATERIAL - FLOODLIGHT LED WATCHMAN
MATERIAL - FLOODLIGHT WATCHMAN
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
09/08/19
09/08/19
09/08/19
01/10/10E 26.06.19
B 19.03.13
C 14.12.18
Construction Type
SLED
@
F
F
F
F
F
F
F
F
F
F
804-6 or 7
Assy Selection300 intervals
Assy 803-6
Assy 805-6
CONNECTION TO OPEN WIRE MAINS
@ 500 crs
Assy 803-1
Refer note 1
Conductor clearance
300
Assy 805-6
Pole
Wood
@ 500 crs
Assy 803-1
CONNECTION TO O/H SERVICE
Assy 804-2 (EGX)
Assy 804-1 (EE) or
Assy 805-1 (EE)
F
F
F
F
CONNECTION TO LV ABC MAINS
300
@ 500 crs
Assy 803-1
Assy 805-6
Pole
Wood
Assy 804-2 (EGX)
Assy 804-1 (EE) or
(Luminaire)
(Luminaire)
SW
SL
(Bracket)
F
Pole
Wood
F
F914-1 to 9
Assy Selection
or 916-1
Assy 915-1
Assy 805-6F
F
Assy 803-1
F
Assy 904-1
lowest point to G.L.
4.5m min. height
F
1-9-3-2
1 9 3-2 0C
LIGHTINGFLOODLIGHTING
WATCHMAN FLOODLIGHT
WOOD POLE - CONSTRUCTION
10500-A4-1-9-3-2
NIL
NIL
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
01/10/10
ASSY DESCRIPTION QTY
914-1
914-2 1
914-3
B 19.03.13
NOTES:
1.
2.
3.
C 03.04.18
25.10.18D
Watchman floodlight L70
Watchman floodlight L100
Watchman floodlight L200
e.g. crossarm, arm braces, etc.
are not contacting other pole top hardware
Bracket / Floodlight shall be mounted such that they
66kV = 1800mm
11kV/22kV/33kV = 1200mm
LV = 100mm
Bracket / Floodlight minimum clearance to conductors:-
on regional location - configuration is illustrative only.
Open wire conductor configuration depends
ASSY DESCRIPTION QTY
1914-6
914-4
914-5
914-7
914-8
914-9
Watchman floodlight S150
Watchman floodlight S250
Watchman floodlight S400
Watchman floodlight H150
Watchman floodlight H250
Watchman floodlight H400
MATERIAL - FLOODLIGHT LED WATCHMAN
MATERIAL - FLOODLIGHT WATCHMAN
ASSY DESCRIPTION QTY
915-2
2804-6
916-2
804-1
804-2
804-7
805-1
805-6
MATERIAL - BRACKET & SUPPLY
Connector I.P.C 25/95mm† main to 6/35mm† tap
6-35mm Aluminium / 4-35mm Copper thru connector
1
AR
AR
Connector tap-off bare aluminium main
Connector tap-off bare copper main
End cap - Push on 25mm† ABC
Conduit PVC flexible - 16mm
866-1 1Fuseholder, with 10A HRC, type 10G (steel / conc)
Bracket LED watchman to steel / conc pole
Bracket watchman floodlight to steel / conc pole
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
09/08/19
09/08/19
09/08/19
01/10/10
1-9-4-1
1 9 4-1 0E
LIGHTINGFLOODLIGHTING
WATCHMAN FLOODLIGHT EXISTING O/H SUPPLY
STEEL / CONCRETE POLE - MATERIAL
10500-A4-1-9-4-1
NIL
4927-A4-15.2
E 26.06.19
Construction Type
SLED
@
F
F
F
F
F
F
F
F
F
F
804-6 or 7
Assy Selection300 intervals
Assy 803-6
Assy 805-6
CONNECTION TO OPEN WIRE MAINS
@ 500 crs
Assy 803-1
300
Assy 805-6
Pole
Wood
@ 500 crs
Assy 803-1
CONNECTION TO O/H SERVICE
Assy 804-2 (EGX)
Assy 804-1 (EE) or
Assy 805-1 (EE)
F
F
F
F
CONNECTION TO LV ABC MAINS
300
@ 500 crs
Assy 803-1
Assy 805-6
Pole
Wood
Assy 804-2 (EGX)
Assy 804-1 (EE) or
(Luminaire)
(Luminaire)
SW
SL
(Bracket)
Assy 866-1
F
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
11/01/19
1-9-4-2
1 9 4-2 0A
LIGHTINGFLOODLIGHTING
WATCHMAN FLOODLIGHT EXISTING O/H SUPPLY
STEEL / CONCRETE POLE - CONSTRUCTION
10500-A4-1-9-4-2
NIL
NIL
F
F
F914-1 to 9
Assy Selection
lowest point to G.L.
4.5m min. height
F
Refer note 1
clearance
Conductor
or 916-2
Assy 915-2
Pole
Steel / Conc
Construction Type
FLOODLIGHTING
LIGHTING
1 9 5-1 0E
F
WATCHMAN FLOODLIGHT EXISTING U/G SUPPLY
Assy 883-1
service not included in this construction
Streetlight pole, luminaire & overhead
4927-A4-15.3
NIL
1-9-5-1
10500-A4-1-9-5-1
B 19.03.13
lowest point to G.L.
4.5m min. height
F
03.04.18C
F
Ø26mm cable entry hole
(part of pole)
15.01.19D
ASSY DESCRIPTION QTY
914-1
914-2 1
914-3
Watchman floodlight L70
Watchman floodlight L100
Watchman floodlight L200
ASSY DESCRIPTION QTY
1914-6
914-4
914-5
914-7
914-8
914-9
Watchman floodlight S150
Watchman floodlight S250
Watchman floodlight S400
Watchman floodlight H150
Watchman floodlight H250
Watchman floodlight H400
MATERIAL - FLOODLIGHT LED WATCHMAN
MATERIAL - FLOODLIGHT WATCHMAN
ASSY DESCRIPTION QTY
915-2
916-2
805-6
MATERIAL - BRACKET & SUPPLY
1
ARConduit PVC flexible - 16mm
883-1 1
Bracket LED watchman to steel / conc pole
Bracket watchman floodlight to steel / conc pole
906-2 ARBandit strap (19mm) to pole
Watchman floodlight circuit breaker
914-1 to 9
Assy Selection
or 916-2
Assy 915-2
F
F
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
09/08/19
09/08/19
09/08/19
01/10/10
FAssy 805-6
STEEL / CONCRETE POLE - CONSTRUCTION
F
Assy 906-2
SLED
(Luminaire) SL
(Luminaire)
E 26.06.19
FLOODLIGHTING
LIGHTING
1 9 6-1 0D
ASSY DESCRIPTION QTY
803-1 AR
MATERIAL
805-6
Saddle (20mm) to wood pole
ARConduit PVC flexible 16mm
not included in this construction
Overhead supply & pole
884-1 1
1-9-6-1
10500-A4-1-9-6-1
4927-A4-15.4
NIL
Consumer’s property pole label
B 19.03.13
C 15.01.19
F
Pole
Wood
914-1 to 9
Assy Selection
or 916-1
Assy 915-1
Assy 805-6
Assy 803-1
Assy 904-1
lowest point to G.L.
4.5m min. height
Construction Type
SLED (Luminaire)
(Luminaire)
SW
SL
(Bracket)
ASSY DESCRIPTION QTY
914-1
914-2 1
914-3
Watchman floodlight L70
Watchman floodlight L100
Watchman floodlight L200
MATERIAL - FLOODLIGHT LED WATCHMAN
915-1
916-11
Bracket watchman floodlight to wood pole
Bracket LED watchman to wood pole
904-1 1Fuseholder, with 10A HRC, type 10G
ASSY DESCRIPTION QTY
1914-6
914-4
914-5
914-7
914-8
914-9
Watchman floodlight S150
Watchman floodlight S250
Watchman floodlight S400
Watchman floodlight H150
Watchman floodlight H250
Watchman floodlight H400
MATERIAL - FLOODLIGHT WATCHMAN
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
09/08/19
09/08/19
09/08/19
01/10/10
PROPERTY POLE O/H SUPPLY - CONSTRUCTION
WATCHMAN FLOODLIGHT EXISTING CUSTOMER
D 26.06.19
F F
MATERIAL - POLE & OUTREACH
ASSY
808-1
808-2
808-3
811-1
QTYDESCRIPTION
DOUBLE OUTREACH POLE ORIENTATION
Traffic flow
Double outreach Traffic flow
Terminal chamber door
1
1
1
1
Terminal panel and cable to single outreach arm
4.5m
3.0m
1.5m
Outreach arm - single
Pole base plate mounted steel
NOTES:
1. Access door to be on side of pole that is least hazardous
to maintenance personnel (normally facing building line).
3. Neutral and earth terminals of terminal panel are to be
bridged. Make bridge only after polarity has been established.
4. Ensure contact area between Base Plate and hold down bolt
washers is clean, free of paint, and bolts are tight.809-8
F
F
FLOODLIGHTING
PEDESTRIAN CROSSING FLOODLIGHT SINGLE - MATERIAL
LIGHITNG
1 9 7-1 0C
MAJOR ROAD BPM STEEL POLE / FOUNDATION - U/G SERVICE
846-1 Pedestrian floodlight outreach extension
refer diagram below.2. For location of terminal chamber relative to double outreach
MATERIAL - FOUNDATION
ASSY DESCRIPTION QTY
813-2
Foundation 350 PCD BPM steel pole - 1 conduit
842-2 Foundation precast 350 PCD BPM steel pole - 1 conduit 1
Foundation 350 PCD BPM (special purpose) - 1 conduit
810-2
7.0m ht.809-6
10.0m ht.
809-7 8.5m ht.
4927-A4-7.4, 2.21, 2.22
NIL
1-9-7-1
10500-A4-1-9-7-1
B 16.01.19
ASSY QTYDESCRIPTION
1
1
868-6
868-4
868-5
868-1
868-2
868-3
Pedestrian Floodlight L100
Pedestrian Floodlight L300
Pedestrian Floodlight S250
Pedestrian Floodlight S400
Pedestrian Floodlight H250
Pedestrian Floodlight H400
1
ASSY DESCRIPTION QTY
869-3 1
1869-2
1869-1
Floodlight adapter - Pierlite
MATERIAL - LUMINAIRE & BRACKET
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
09/08/19
09/08/19
09/08/19
01/10/10
02.08.19C
868-7 Pedestrian Floodlight L200 1 869-4 1
Floodlight adapter - Philips Tango (small)
Floodlight adapter - HID
Floodlight adapter - Philips Tango (medium)
F
FF
F
F
F F
F
BPM BASE PLATE MOUNTED POLE
PROPERTY
SIDE
40 Grout
2.0m
ROAD
SIDE
special purpose only.
For shallow foundationConstruction Type
Drawing No. 1-4-7-1
Refer Services
Underground service.
Drawing 1-3-7-1
refer Construction Practices
Stabilisied backfill foundation F
}(normal soil)
808-1 to 3
Assy Selection
12.0m
10.5m
9.0m
Height
Mounting
Nominal
10.0m
8.5m
7.0m
Height
Pole
FLOODLIGHTING
MAJOR ROAD BPM STEEL POLE / FOUNDATION - U/G SERVICE
LIGHTING
1 9 7-2 0C
F
F
F
PEDESTRIAN CROSSING FLOODLIGHT SINGLE - CONSTRUCTION
F
842-2
810-2 or
Assy Selection
813-2
Assy Selection
809-6, 7 or 8
Assy Selection
(Luminaire) SLED
Refer Assemblies - Page 1-2-810 note 7.
For unsuitable soil conditions.
4927-A4-7.4, 2.21, 2.22
NIL
1-9-7-2
10500-A4-1-9-7-2
811-1
Assy Selection
B 16.01.19
F
F
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
09/08/19
09/08/19
09/08/19
01/10/10
846-1
Assy Selection
868-1 to 7
869-1 to 4 and
Assy Selection
(Luminaire) SL
02.08.19C
F F
MATERIAL - POLE & OUTREACH
ASSY
808-1
808-2
808-3
811-1
811-2
MATERIAL - FOUNDATION
ASSY DESCRIPTION QTY
QTYDESCRIPTION
DOUBLE OUTREACH POLE ORIENTATION
Traffic flow
Double outreach Traffic flow
Terminal chamber door
1
1
1
Terminal panel and cable to double outreach arm
Terminal panel and cable to single outreach arm
4.5m
3.0m
1.5m
Outreach arm - single
NOTES:
1. Access door to be on side of pole that is least hazardous
to maintenance personnel (normally facing building line).
3. Neutral and earth terminals of terminal panel are to be
bridged. Make bridge only after polarity has been established.
4. Ensure contact area between Base Plate and hold down bolt
washers is clean, free of paint, and bolts are tight.
813-2
Foundation 350 PCD BPM steel pole - 1 conduit
842-2 Foundation precast 350 PCD BPM steel pole - 1 conduit 1
Foundation 350 PCD BPM (special purpose) - 1 conduit
F
F
810-2
FLOODLIGHTING
PEDESTRIAN CROSSING FLOODLIGHT SINGLE - MATERIAL
LIGHITNG
1 9 8-1 0C
MAJOR ROAD BPM STEEL POLE / FOUNDATION - O/H SERVICE
846-1 Pedestrian floodlight outreach extension
refer diagram below.2. For location of terminal chamber relative to double outreach
807-6 1
804-1
800-6
Supply to terminal panel steel pole
Eyebolt & eyenut M16 x 150 to streetlight pole
809-6
809-7
809-8
Pole base plate mounted steel
7.0m ht.
8.5m ht.
10.0m ht.
1
4927-A4-5.3, 2.21, 2.22
NIL
1-9-8-1
10500-A4-1-9-8-1
804-2
805-1
6-35mm Aluminium / 4-35mm Copper Thru Connector
Connector I.P.C. 25/95mm† main to 6/35mm† tap
End cap - push on 25mm† ABC
2
B 18.01.19
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
09/08/19
09/08/19
09/08/19
01/10/10
ASSY QTYDESCRIPTION
1
1
868-6
868-4
868-5
868-1
868-2
868-3
Pedestrian Floodlight L100
Pedestrian Floodlight L300
Pedestrian Floodlight S250
Pedestrian Floodlight S400
Pedestrian Floodlight H250
Pedestrian Floodlight H400
1
ASSY DESCRIPTION QTY
869-3 1
1869-2
1869-1
Floodlight adapter - Pierlite
MATERIAL - LUMINAIRE & BRACKET
868-7 Pedestrian Floodlight L200 1 869-4 1
Floodlight adapter - Philips Tango (small)
Floodlight adapter - HID
Floodlight adapter - Philips Tango (medium)
02.08.19C
1
F
FF
F
F
F F
F
BPM BASE PLATE MOUNTED POLE
PROPERTY
SIDE
40 Grout
2.0m
ROAD
SIDE
special purpose only.
For shallow foundation
Construction Type
(Luminaire)Drawing 1-3-7-1
refer Construction Practices
Stabilisied backfill foundation F
}(normal soil)
12.0m
10.5m
9.0m
Height
Mounting
Nominal
10.0m
8.5m
7.0m
Height
Pole
FLOODLIGHTING
MAJOR ROAD BPM STEEL POLE / FOUNDATION - O/H SERVICE
LIGHTING
1 9 8-2 0C
F
811-1 or 2
Assy Selection
F
PEDESTRIAN CROSSING FLOODLIGHT SINGLE - CONSTRUCTION
F
Assy 800-6
Fully ribbed core
is neutralDrawing No. 1-4-3-1, 1-4-4-1 & 1-4-5-1
Overhead service. Refer Services
F
F
842-2
810-2 or
Assy Selection
813-2
Assy Selection
809-6, 7 or 8
Assy Selection
SLED
Refer Assemblies - Page 1-2-810 note 7.
For unsuitable soil conditions.
4927-A4-5.2, 2.21, 2.22
NIL
1-9-8-2
10500-A4-1-9-8-2
Assy 805-1 (EE)
Assy 804-2 (EGX)
Assy 804-1 (EE) or
B 18.01.19
F
807-6
F
808-1 to 3
Assy Selection
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
09/08/19
09/08/19
09/08/19
01/10/10
F
F
846-1
Assy Selection
868-1 to 7
869-1 to 4 and
Assy Selection
SL(Luminaire)
(Pole, Outreach & Foundation) SLBPM
02.08.19C
MATERIAL - POLE & OUTREACH
ASSY QTYDESCRIPTION
1
1
1
NOTES:
13.0m height809-9
893-1 Pedestrian Outreach Arm PF3
Pole base plate mounted steel
7.0m height
8.5m height
10.0m height
809-6
809-7
809-8
811-2 Terminal panel and cable to double outreach arm
washers is clean, free of paint and bolts are tight.3. Ensure contact area between Base Plate and hold down bolt bridged. Make bridge only after polarity has been established.2. Neutral and earth terminals of terminal panel are to be to maintenance personnel (normally facing building line)1. Access door to be on side of pole that is least hazardous
ASSY DESCRIPTION QTY
841-4
841-1
841-2
841-31
MATERIAL - FOUNDATION
Foundation 350 PCD BPM steel pole - 1 conduit
Foundation 500 PCD BPM steel pole - 1 conduit
Foundation 350 PCD BPM steel pole - 1 conduit
Foundation 350 PCD BPM (special purpose) - 1 conduit
B 02.08.19
1-9-11-1
1 9 11-1 0B
LIGHTINGFLOODLIGHTING
BPM U/G FOUNDATION PEDESTRIAN CROSSING
FLOODLIGHT COMBINATIONS - MATERIAL
10500-A4-1-9-11-1
NIL
NIL
ASSY QTYDESCRIPTION
1
1
868-6
868-4
868-5
868-1
868-2
868-3
Pedestrian Floodlight L100
Pedestrian Floodlight L300
Pedestrian Floodlight S250
Pedestrian Floodlight S400
Pedestrian Floodlight H250
Pedestrian Floodlight H400
1
ASSY DESCRIPTION QTY
869-3 1
1869-2
1869-1
Floodlight adapter - Pierlite
MATERIAL - LUMINAIRE & BRACKET
868-7 Pedestrian Floodlight L200 1 869-4 1
Floodlight adapter - Philips Tango (small)
Floodlight adapter - HID
Floodlight adapter - Philips Tango (medium)
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
09/08/19
09/08/19
09/08/19
14/10/10
F
FF
F
F
F
F
F
F
BPM BASE PLATE MOUNTED POLE
40 Grout
PROPERTY
SIDE
special purpose only.
For shallow foundation
ROAD
SIDE
2.0m
F
F809-6 to 9
Assy Selection
13.0m
10.0m
8.5m
7.0m
Height
Pole
15.0m
12.0m
10.5m
9.0m
Height
Mounting
Nominal
SLBPM
Construction Type
(Pole, Outreach & Foundation)
Refer 1-2-810 note 7.
For unsuitable soil conditions.
813-2
Assy Selection
(normal soil)}842-2
839-2 or
810-2 or
Assy Selection
811-2
Assy Selection
Drawing No. 1-4-7-1
Refer Services
Underground service.
For Precast Foundations
Drawing No. 1-3-7-1
Refer Construction Practices
Stabilised backfill foundation
F
F893-1
Assy Selection
F
B 02.08.19
1-9-11-2
1 9 11-2 0B
LIGHTINGFLOODLIGHTING
BPM FOUNDATION - U/G SVC PEDESTRIAN CROSSING
FLOODLIGHT COMBINATIONS - CONSTRUCTION
10500-A4-1-9-11-2
NIL
NIL
868-1 to 7
869-1 to 4 and
Assy Selection
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
09/08/19
09/08/19
09/08/19
14/10/10
(Luminaire)
(Luminaire) SLED
SL