Lift column LP 192 2009.08.19 - Movetec · Lifting column LP 192 EU/UK/US/CAN version ... The...

16
Lifting column LP 192 EU/UK/US/CAN version Industry Actuators Control boxes Accessories Controls Cables and adapters Dimensions Applications Preliminary

Transcript of Lift column LP 192 2009.08.19 - Movetec · Lifting column LP 192 EU/UK/US/CAN version ... The...

Page 1: Lift column LP 192 2009.08.19 - Movetec · Lifting column LP 192 EU/UK/US/CAN version ... The column consists of a telescopic aluminium tubing fitted with large slide ... Mains cable

Lifting column LP 192

EU/UK/US/CAN version

Ind

ustr

y

Actuators

Control boxes

Accessories

Controls

Cables and adapters

Dimensions

Applications

Preliminary

Page 2: Lift column LP 192 2009.08.19 - Movetec · Lifting column LP 192 EU/UK/US/CAN version ... The column consists of a telescopic aluminium tubing fitted with large slide ... Mains cable

MPI Lifting columns – for comfortable working positions

Fast and easy height adjustment of work areas is important for peoplethat wish to work at the correct ergonomic level during all operations.

The column consists of a telescopic aluminium tubing fitted with large slidebearings to provide maximum stability.

Electrical height adjustment for single or parallel operation with up to 4columns.

Lift force up to 3000N or 6000N single.

Stroke length 300,400 or 500 mm.

Speed up to 11 mm/sec without load.

Max bending moment 1000 Nm (stat.) 750 Nm (dyn.), at full stroke length.

Intermittent duty 10% for a maximum of 2 min continuous duty for 15 min.

These columns have to be completed with control box, cable handset,underdesk control or footcontrol.

Cable output at the top of column.

Type Force [N] Article numberCable

length [mm]

Installation

length [mm]

Stroke

[mm]

ColorPlugSpeed

[mm/sec.]

Actuator

www.okin.netOKIN Motion Technologies GmbH

created by AKO 2009-08-17REV 1.0

-2-

ActuatorActuatorType : LP 192

Documentation MPI / Lifting - columns industry

LP 192 Control box group:A

165 mm

192 mm

175 mm

135 mm

USD

LP 192 3000 1.41.000.???.10LP 192 3000 1.41.000.???.10LP 192 3000 1.41.000.???.10

LP 192 6000 1.41.000.???.10LP 192 6000 1.41.000.???.10LP 192 6000 1.41.000.???.10

aluminium light anodizedOmegadrive 8-pin straight 1200 aluminium light anodized

672 500 11* Omegadrive 8-pin straight 1200

472 300 11* Omegadrive 8-pin straight 1200 aluminium light anodized

120012001200500672

472 300 aluminium light anodized8-pin straight8-pin straight aluminium light anodized

aluminium light anodized

6*6*6*

572 400

572 400 11*

8-pin straight

OmegadriveOmegadriveOmegadrive

YYY

YYY

* without load ( 24V DC)

Installation

Stroke length

height

LP 192 3000LP 192 3000LP 192 3000

12001200

472572672

400500

8-pin straight1200Omegadrive 8-pin straight aluminium light anodized300

aluminium light anodizedaluminium light anodized8-pin straight

OmegadriveOmegadrive

LP 192 6000LP 192 6000LP 192 6000

12001200

472572672

400500

6*6*

8-pin straight12006* Omegadrive 8-pin straight aluminium light anodized300

aluminium light anodizedaluminium light anodized8-pin straight

OmegadriveOmegadrive

1.41.000.???.101.41.000.???.101.41.000.???.10

1.41.000.???.101.41.000.???.101.41.000.???.10

NNN

NNN

11*

11*11*

OP

TIO

N

Option:Standard:

STA

ND

AR

D

Preliminary

Page 3: Lift column LP 192 2009.08.19 - Movetec · Lifting column LP 192 EU/UK/US/CAN version ... The column consists of a telescopic aluminium tubing fitted with large slide ... Mains cable

CBXi-240VA-A EU Art.-No.

1.47.000.082.30

Art.-No.

1.47.000.083.30

Art.-No.

1.47.000.084.30

Art.-No.

1.47.000.085.30

* not available CBXi

4

LDB-4-340VA-EU/UK

Power 340 VASoft synchronization of 4 OKIN actuators

Application: System with four (4) actuators

LDS-2-240VA-EU/UK

Power 240 VASoft synchronization of 2 OKIN actuators

Application: System with two (2) actuators

LDS-3-340VA-EU/UK

Power 340 VASoft synchronization of 3 OKIN actuators

Application: System with three (3) actuators

CONTROLSCONTROLSControl boxes: EU/UK Version

General instructions:

Serial features : Optional features :

Output of service data to Handset with display

Versions for US and CAN available

Integrated toroidal transformerExchangeable mains cable *Microprocessor technologySynchronic control of actuator systemsSoftstart and softstop

The "Synchronic-Control" control-family has been specially designed for electricalheight adjusting systems and can be used for synchronization of 2-4 OKIN actuators.

Soft synchronization of 2 OKIN actuators

Application: System with two (2) actuators

Power 240 VA

MemoryDisplay

www.okin.netOKIN Motion Technologies GmbH

created by AKO 2009-08-17REV 1.0

-3-

Preliminary

Page 4: Lift column LP 192 2009.08.19 - Movetec · Lifting column LP 192 EU/UK/US/CAN version ... The column consists of a telescopic aluminium tubing fitted with large slide ... Mains cable

CBX-240VA-A US/CAN Art.-No.

1.47.000.042.30

Art.-No.

1.47.000.092.30

Art.-No.

1.47.000.093.30

Art.-No.

1.47.000.072.30

4

LDB-4-340VA-US/CAN

Power 340 VASoft synchronization of 4 OKIN actuators

Application: System with four (4) actuators

LDS-2-240VA-US/CAN

Power 240 VASoft synchronization of 2 OKIN actuators

Application: System with two (2) actuators

LDS-3-340VA-US/CAN

Power 340 VASoft synchronization of 3 OKIN actuators

Application: System with three (3) actuators

CONTROLSCONTROLSControl boxes: US/CAN Version

General instructions:

Serial features : Optional features :

Output of service data to Handset with display

Versions for US and CAN available

Integrated toroidal transformerExchangeable mains cableMicroprocessor technologySynchronic control of actuator systemsSoftstart and softstop

The "Synchronic-Control" control-family has been specially designed for electricalheight adjusting systems and can be used for synchronization of 2-4 OKIN actuators.

Soft synchronization of 2 OKIN actuators

Application: System with two (2) actuators

Power 240 VA

MemoryDisplay

www.okin.netOKIN Motion Technologies GmbH

created by AKO 2009-08-17REV 1.0

-4-

Preliminary

Page 5: Lift column LP 192 2009.08.19 - Movetec · Lifting column LP 192 EU/UK/US/CAN version ... The column consists of a telescopic aluminium tubing fitted with large slide ... Mains cable

AccessoriesAccessories

Art.-No.

3.00.401.108.30

3.00.401.105.30UK-British type plug with fuse 5A

3,0 m EU-2-pol European flat plug

Length Country

Mains cable for LDS-2,LDS-3,LDB-4

3,0 m

Power Pack 1180mAh

Euro Charger for Power Pack

Art.-No.

1.14.000.071.30

Art.-No.

3.00.699.034.00

POWER PACK 1180-V2+1xmounting bracket+2xBÜG.+4xS. AK-SW-1,18AH-29,4V-AKUST.S./EXT.LB

ST.NT. EURO M. MAIN SOCKET 230V/29,4V 2,94VA

Art.-No.

3.00.699.042.00

ST.NT. UK M. MAIN SOCKET 240V/29,4V 2,94VA 100mA

3.00.401.129.303,0 m US-2-pol American flat plug

www.okin.netOKIN Motion Technologies GmbH

created by AKO 2009-08-17REV 1.0

-5-

Preliminary

Page 6: Lift column LP 192 2009.08.19 - Movetec · Lifting column LP 192 EU/UK/US/CAN version ... The column consists of a telescopic aluminium tubing fitted with large slide ... Mains cable

AccessoriesAccessoriesApplication Power Pack 1180mAh

PowerPackArt.-No.1.14.000.070.30

Euro charger with cable

1.8m and LEDArt.- No.3.00.699.034.00

Plug charging set

with charger lead1.8 m and LED

3.00.699.034.00

Under desk version

Art.-No.

Art.-No.1.14.000.071.30

PowerPack with 5-Pindiode connector

Art.-No.5.00.4v0.011.30

HS-Extension 6x0,34MM²black 1500mm

www.okin.netOKIN Motion Technologies GmbH

created by AKO 2009-08-17REV 1.0

-6-

Art.-No.3.00.402.397.30

Extension cable stereo 3,5mmblack 2000mm

Preliminary

Page 7: Lift column LP 192 2009.08.19 - Movetec · Lifting column LP 192 EU/UK/US/CAN version ... The column consists of a telescopic aluminium tubing fitted with large slide ... Mains cable

AccessoriesAccessories

nominal capacity average 1180 mAh

minimum capacity 1100 mAh

nominal voltage 29.4 V

Power cycles 80% remaining capacity after 300 charging cycles

output current 5A DC

minimum discharge voltage 19 V

acoustic signal if U Akku 22V, and I load 0,6A

>

-

>->

-

low discharge rateshort circuit prooftemperature range 0 - 40C°option: mounting bracketcharging time from 10 to 15 hoursacoustic warning signal for urgent rechargingif motor current is requestedlow weight g450

Technical details Power Pack

Features Power Pack

5-25 cycles

1180 mAh = 1, 18 Ah = 4248 Asec.

current consumption for a LP 192single

to run out to run in

i.e. 3000N (300) 55 sec.2,5A 30 sec.1,0A 168 Asec.i.e. 6000N (500) 167 sec. 4,0A 85 sec.2,0A 838 Asec.

4248 Asec.= 25 cycles for 3000N

168 Asec.

4248 Asec.= 5 cycles for 6000N

838 Asec.

Estimation example

www.okin.netOKIN Motion Technologies GmbH

created by AKO 2009-08-17REV 1.0

-7-

Preliminary

Page 8: Lift column LP 192 2009.08.19 - Movetec · Lifting column LP 192 EU/UK/US/CAN version ... The column consists of a telescopic aluminium tubing fitted with large slide ... Mains cable

The SMPS is used to supply OKIN actuators and controls.

World wide applicableHigh input voltage range 100VAC-240VACFully protectedNominal output current: 2ANominal output voltage: 28VDC

AccessoriesAccessoriesSMPS

Mains cable for SMPS, Power Pack

Extension cable for SMPS, Power Pack

Art.-No.

3.00.402.207.30

Art.-No.

3.00.401.125.30

Art.-No.

3.00.401.126.30

Art.-No.

3.00.209.010.00

Art.-No.

3.00.209.014.00

SMPS UNIVERSAL SP2-A/4/AC 100-240V/DC 29V/NO CORD

SMPS UNIVERSAL/BATTERY BACKUP SP2-B/4/AC 100-240V/DC 29V NO CORD

MAINS CABLE FOR SMPS UNIVERSAL 1200MM EU VERSION

MAINS CABLE FOR SMPS UNIVERSAL 1200MM UK VERSION

EXTENSIONS CABLE 2x0,75MM²x1500MM BLACK

Battery backup: Lowering without MAIN power

Art.-No.

3.00.401.127.30

Art.-No.

3.00.401.130.30

MAINS CABLE FOR SMPS UNIVERSAL 1200MM US/JP VERSION

MAINS CABLE FOR SMPS UNIVERSAL 1200MM AUS VERSION

www.okin.netOKIN Motion Technologies GmbH

created by AKO 2009-08-17REV 1.0

-8-

Preliminary

Page 9: Lift column LP 192 2009.08.19 - Movetec · Lifting column LP 192 EU/UK/US/CAN version ... The column consists of a telescopic aluminium tubing fitted with large slide ... Mains cable

AccessoriesAccessoriesTechnical details SMPS

Nominal ratings:

Line voltage: 100VAC...240VAC(+/-10%) Nominal outputcurrent:

2A

Nominal output-Voltage

29VDC

Absolute maximum ratings:

The power supply has internal protection circuits which prevent the supply to exceed the ratings below!

Protection: In case of overloading the power supply (output current >2A) for more then 2min, the below listed values may not be reached.

0...4A(constant voltagerange)

Line voltage: 90... 264VAC 50/60Hz Output current:

4...8,5A (constantpower range)

Output-Voltage

between 0 4A load: 29VDCOutput-Voltage at maxload (8,5A): 13VDC

General technical data’s:

Ripple 100 mVp-p;Standby power: Ripple and noise:

Noise 200 mVp-pOver temperature;

Output spikes;

Protection against:

Short circuit;

Standards: CE; UL

Protection degree: IP50

_

_

>>100V±10%; 1W±20%

240V±10%; 1W±20%_

_

>>

EnvironmentalConditions :

Operating:

The power supply shallbe capable of operatingcontinuously in anymode withoutperformance lossin the followingenvironmental conditions.

Non Operating:

The Power supply shallbe capable of standingthe followingenvironmental conditionsextended periods of time ,without sustainingelectrical or mechanicaldamage andsubsequent operationaldeficiencies:

Ambient Temperature:

0°C- 40°C

Ambient Temperature:

0°C – 70°C

Relative Humidity:

20% - 95%

Relative Humidity:

20% - 95%

I

UI I_cut off

about 8,5A

I_2

I_1about 4,0 A

29VDC

Constantvoltagerange

Constantpower

13VDC

Voltage & current characteristic

www.okin.netOKIN Motion Technologies GmbH

created by AKO 2009-08-17REV 1.0

-9-

Preliminary

Page 10: Lift column LP 192 2009.08.19 - Movetec · Lifting column LP 192 EU/UK/US/CAN version ... The column consists of a telescopic aluminium tubing fitted with large slide ... Mains cable

ControlsControls

Underdesk control for CBXi,LDS-2,LDS-3,LDB-4

HSCO-OD-2-OK Art.-No.1.32.000.087.30Up/down handset with 2 buttons

Keypad slightly crooked for easy use

Under table top mounting

Art.-No.1.32.000.032.30

HSU-OD-2-LD

Up/down handset with 2 buttonsKeypad slightly crooked for easy useUnder table top mountingExtendable comfort switch

Art.-No.1.32.000.069.30

HSX-OD-2-LD

Up/down handset with 2 buttonsUnder table top mounting

Art.-No.1.32.000.079.30

UNDERDESK-HANDSET BLACK HS+1

Up/down handset with 2 buttons

LED feedbackUnder table top mounting

Art.-No.1.32.000.007.26

UNDERDESK-HANDSET GRAPHITE GREY HS+1

Up/down handset with 2 buttons

LED feedbackUnder table top mounting

Charge socket for Power Pack

Mono Jack

Art.-No.1.32.000.046.30

UNDERDESK-HANDSET BLACK HS+1

Up/down handset with 2 buttons

LED feedbackUnder table top mounting

Charge socket for Power PackMono Jack

Underdesk control for Power Pack or SMPS system

www.okin.netOKIN Motion Technologies GmbH

created by AKO 2009-08-17REV 1.0

-10-

Preliminary

Page 11: Lift column LP 192 2009.08.19 - Movetec · Lifting column LP 192 EU/UK/US/CAN version ... The column consists of a telescopic aluminium tubing fitted with large slide ... Mains cable

ControlsControlsUnderdesk control for CBXi,LDS-2,LDS-3,LDB-4

Art.-No.1.32.000.076.30

HSE-MDF-2-LD

Modern up/down switch with 2 buttonsBuilt-in underdesk controlDisplay of table height: in cm or optionally in inchOutput of a service code

Art.-No.1.32.000.063.30

HSU-MDF-4M2-LD-2Comfort handset with 7 buttons and LED-display

Display of table height: cm or inch

Keypad slightly crooked for easy use

Output of a service code

Under table top mounting

Extendable comfort handsetUp/down-, memory- with 4 position-retreiving buttons

Art.-No.

1.32.000.097.30HSF-MDF-4M4-LD

Highend Handset 9 buttons and LED-display

Under table top mounting

Up/down-, memory- with 4 position-retreiving buttons

Output service code

Display of table height: in cm or optionally in inch

Keypad slightly for easy usecrooked

Ultra-flat

Extendable top-comfort-plug with LED height-display

Underdesk control for CBXi,LDS-2,LDS-3,LDB-4

2 motor groups

OPTION

www.okin.netOKIN Motion Technologies GmbH

created by AKO 2009-08-17REV 1.0

-11-

Preliminary

Page 12: Lift column LP 192 2009.08.19 - Movetec · Lifting column LP 192 EU/UK/US/CAN version ... The column consists of a telescopic aluminium tubing fitted with large slide ... Mains cable

ControlsControls

Art.-No.1.11.000.385.30

HS PROLINE V5/SW/SW-WS/R/m.H.STAND. o.SYMBClassic handset with 2 buttonsFor one motor groupRecessed buttons to prevent accidental operation

Cablehandset for CBXi,LDS-2,LDS-3,LDB-4

Art.-No.1.45.000.003.30

FOOTCONTROL OK+1 SW/R

Footcontrol with 2 pedal switchesFor one motor group

Footcontrol for CBXi,LDS-2,LDS-3,LDB-4

With hook

Art.-No.

1.11.000.386.30HS PROLINE V7/SW/SW-WS/R/m.H.STAND.

Classic handset with 4 buttons

Recessed buttons to prevent accidental operationFor two motor groups

With hook

Handset for CBXi,LDS-2,LDS-3,LDB-4

standard flex magnet

OPTION HOOK

Art.-No.

2.00.631.000.30

Art.-No.

2.00.631.001.30

Art.-No.

2.00.631.800.30

www.okin.netOKIN Motion Technologies GmbH

created by AKO 2009-08-17REV 1.0

-12-

Preliminary

Page 13: Lift column LP 192 2009.08.19 - Movetec · Lifting column LP 192 EU/UK/US/CAN version ... The column consists of a telescopic aluminium tubing fitted with large slide ... Mains cable

Cable and adaptersCable and adapters

Art.-No.5.00.4v0.095.30

Extension cable for app. 3.0 mactuator

Art.-No.5.00.4v0.067.30

Extension cable for app. 1.5 mactuator

Extension cable for actuators

Art.-No.5.00.4v0.102.30

Extension cable for actuator app. 0.1 m

Art.-No.3.00.402.248.30

Extension cable for handset app. 0.1 m

Art.-No.5.00.4v0.052.30

Extension cable for handset app. 2.0 m

Extension cable handsets CBXi,LDS-2,LDS-3,LDB-4

Y- cable 2 handsets CBXi,LDS-2,LDS-3,LDB-4

Art.-No.5.00.4v0.105.30

Adapter cable for 5-plug-socket 0.1m

Cable for endposition programming

www.okin.netOKIN Motion Technologies GmbH

created by AKO 2009-08-17REV 1.0

-13-

Preliminary

Page 14: Lift column LP 192 2009.08.19 - Movetec · Lifting column LP 192 EU/UK/US/CAN version ... The column consists of a telescopic aluminium tubing fitted with large slide ... Mains cable

DimensionsDimensions

8

Stro

ke+

17

2

12,5225

250

18

13

4

17

0

192,5

174,5135

164,9

�1

0,5

(4x)

www.okin.netOKIN Motion Technologies GmbH

created by AKO 2009-08-17REV 1.0

-14-

Preliminary

Page 15: Lift column LP 192 2009.08.19 - Movetec · Lifting column LP 192 EU/UK/US/CAN version ... The column consists of a telescopic aluminium tubing fitted with large slide ... Mains cable

DimensionsDimensions2-parallel systems

Control box CBX i or LDS-2Underdesk control

Lift colum 2Lift colum 1

240V 50HZ

Lift colum 2Lift colum 1 Lift colum 3

Underdesk control

240V 50HZ

Control box LDS-3

3-parallel systems

www.okin.netOKIN Motion Technologies GmbH

created by AKO 2009-08-17REV 1.0

-15-

Preliminary

Page 16: Lift column LP 192 2009.08.19 - Movetec · Lifting column LP 192 EU/UK/US/CAN version ... The column consists of a telescopic aluminium tubing fitted with large slide ... Mains cable

DimensionsDimensions

Lift colum 2Lift colum 1 Lift colum 3 Lift colum 4

Underdesk control

240V 50HZ

Control box LDB-4

4-parallel systems

www.okin.netOKIN Motion Technologies GmbH

created by AKO 2009-08-17REV 1.0

-16-

Preliminary