    Level is measured at the position of the

    interface between phases, where the phases

    are liquid/gas, solid/gas, or immiscibleliquid/liquid and after reaching certain

    level,switch turns the equipment ON & OFF.

    Level is simply a measure of height.

  • 8/3/2019 Level Switches 34

    3/25

    Direct

    Indirect

  • 8/3/2019 Level Switches 34

    4/25

    Direct methods employ physical

    properties such as fluid motion and

    buoyancy, as well as optical, thermal,

    and electrical properties. Direct level

    measurement does not require

    compensation for changes in level

    caused by changes in temperature.

    Direct level measurements show the

    actual level of the interface.

  • 8/3/2019 Level Switches 34

    5/25

    Indirect level measurement involves

    converting measurements of some other

    quantity, such as pressure to level by

    determining how much pressure is

    exerted over a given area at a specific

    measuring point, the height of thesubstance above that measuring point

    can also be determined.

  • 8/3/2019 Level Switches 34

    6/25

    A dipstick used to measure the amount of fuel

    remaining in a tank. Dipsticks can also be usedto measure the quantity of liquid in an otherwiseinaccessible space, by inserting and removingthe stick and then checking the extent of itcovered by the liquid.

  • 8/3/2019 Level Switches 34

    7/25

    Rotating paddle level sensorsare a very old and establishedtechnique for bulk solid pointlevel indication. The techniquerequires a low speed gear motorthat rotates a paddle wheel.When the paddle is stalled by

    solid materials, the motor isrotated on its shaft by its owntorque until a flange mounted onthe motor contacts a mechanical

    switch

  • 8/3/2019 Level Switches 34

    8/25

    A sight glass or water gauge is atransparent tube through which the operatorof a tank or boiler can observe the level ofliquid contained within. Simple sight glasses

    may be just a plastic or glass tubeconnected to the bottom of the tank at oneend and the top of the tank at the other. Thelevel of liquid in the sight glass will be the

    same as the level of liquid in the tank.Today, however, sophisticated floatswitches have replaced sight glasses inmany such applications.

  • 8/3/2019 Level Switches 34

    9/25

    It is used to measure liquidlevels in the tank in which a floatrests on the surface of liquid andfollows the changing level of

    liquid.

  • 8/3/2019 Level Switches 34

    10/25

    Ultrasonic transmitters work on theprinciple of sending a sound wave from apeizo electric transducer to the contents of

    the vessel. The device measures the lengthof time it takes for the reflected sound waveto return to the transducer. A successfulmeasurement depends on reflection fromthe process material in a straight line backto the transducer

  • 8/3/2019 Level Switches 34

    11/25

    The Metritape sensor comprises an

    elongated metallic base strip having

    electrical insulation on the edges and back

    of the strip to define an un-insulated zonealong the length of the base strip, and a

    resistance wire or ribbon helically wound

    around the insulated base strip, with thehelical turns bridging the insulated edge

    portions being spaced from the underlying

    un-insulated zone of the base strip.

  • 8/3/2019 Level Switches 34

    12/25

    Hook- Type level Indicator consists of a wire of

    corrosion resistance alloy bent into U-shaped withone arm longer than the other. The shorter arm is

    pointed with 60 degrees while the longer is

    attached to a slider on a Vernier scale, which

    moves over the main scale and shows the reading.

  • 8/3/2019 Level Switches 34

    13/25

    Displacer level detector workson the Archimedes Principlewhich states, A body whollyor partially immersed in fluid isbuoyed up a force which isequal to weight of the fluiddisplaced. By detecting the

    apparent weight of immerseddisplacer the level of the fluidis measured

  • 8/3/2019 Level Switches 34

    14/25

    High accuracy

    Reliable for clean liquids

    Can be mounted internally or externally

    Externally mounted can be disconnect

    from main unit for maintenance

    Adoptable to liquid interfacemeasurement

  • 8/3/2019 Level Switches 34

    15/25

  • 8/3/2019 Level Switches 34

    16/25

    Key questions to ask before selecting a level measurementsensor:

    1. Are you measuring a liquid or solid?

    2. What is the applications temperature and pressure

    ranges?

    3. Is point level or continuous measurement required?

    4. What level measurement range do you need?

  • 8/3/2019 Level Switches 34

    17/25

    5. Is the measured material electricallyconductive?

    6. Will the material coat or build up on surfaces?

    7. Does turbulence, foam, or vapor occur at the

    surface of the liquid?

    8. Will you need contact or non-contact levelmeasurement?

    9. What kind of output do you needanalog,relay, digital display, etc.?

  • 8/3/2019 Level Switches 34

    18/25

    Switches

    A switch is an electrical deviceusually electromechanical used tocontrol continuity between two

    points

  • 8/3/2019 Level Switches 34

    19/25

    Types of SwitchesHand switches: Hand Switches are

    actuated by human touch.Process Switches: Process Switches areactuated by changes in some physical

    process(temperature ,level , flow etc.)Limit Swiches:Limit Switches are actuatedby machine motion.

  • 8/3/2019 Level Switches 34

    20/25

    Liquid Level SwitchesA floating object can be used to actuate aswitch mechanism when the liquid level in

    an tank rises past a certain point.

  • 8/3/2019 Level Switches 34

    21/25

    Nuclear Level SwitchesBoth source and detector are outside

    of the vessel, with no intrusion at allexcept the radiation flux itself. Theradioactive sources used are fairly

    weak and pose no immediate healththreat to operations or maintenancepersonnel.

  • 8/3/2019 Level Switches 34

    22/25

  • 8/3/2019 Level Switches 34

    23/25

    Float Level SwitchesAll float operated liquid level controls operate

    on the basic buoyancy principle which states"the buoyancy force action on an object isequal to the mass of liquid displaced by theobject."

  • 8/3/2019 Level Switches 34

    24/25

    Difference Between

    Sensor,Switch & transducerSensor:Tell us the value

    Switch: Turns something ON or OFF

    Transducer: A sensor that can send asignal

  • 8/3/2019 Level Switches 34

    25/25

    The many level technologies available in the market place

    today all work. If they did not work, companies would not

    be able to stay in business manufacturing them, and other

    companies would not be buying them. The important thing

    to remember is that all technologies work when applied

    properly. Special consideration must always be given to the

    principle of operation, and where the limitations of each

    technology lie. The correct selection of a technology and

    then the subsequent correct application of the technology

    will make the level measurement a successful one.