![Page 1: Level 1 Failure Analysis - EAG Laboratories · Copyrigh 01 EAG Inc AN46 8.13 EAG.CM MATEIALS SCIECES Level 1 Failure Analysis Level 1 FAs include: non-destructive tests, optical inspection,](https://reader031.fdocuments.us/reader031/viewer/2022011802/5b2ac1697f8b9a980b8b48f6/html5/thumbnails/1.jpg)
Copyright © 2013 EAG, Inc. AN469 08.13 EAG.COM
MATERIALS SCIENCES
Level 1 Failure AnalysisLevel 1 FAs include: non-destructive tests, optical inspection, X-ray, C-SAM, and electrical characterization. This can complete an analysis or indicate the path for deeper analyses.
2015 M-009316 06.15
PACKAGE OPTICAL INSPECTION
C-SAM INSPECTION THRU SCAN
X-RAY INSPECTION
Paddle Die Surface
EAG.COM+1 800 366 3867
Voids in the die attach are observed
![Page 2: Level 1 Failure Analysis - EAG Laboratories · Copyrigh 01 EAG Inc AN46 8.13 EAG.CM MATEIALS SCIECES Level 1 Failure Analysis Level 1 FAs include: non-destructive tests, optical inspection,](https://reader031.fdocuments.us/reader031/viewer/2022011802/5b2ac1697f8b9a980b8b48f6/html5/thumbnails/2.jpg)
Copyright © 2013 EAG, Inc. AN469 08.13 EAG.COM
Level 1 Failure Analysis
2015 M-009316 06.15
ELECTRICAL CHARACTERIZATION
Drain I-V curve: Good vs. Leaky device Drain I-V curve: Good vs. Short device
Gate I-V curve: Good vs. Leaky device
Vth I-V curve: Good vs. Leaky device
Gate I-V curve: Good vs. Short device
![Page 3: Level 1 Failure Analysis - EAG Laboratories · Copyrigh 01 EAG Inc AN46 8.13 EAG.CM MATEIALS SCIECES Level 1 Failure Analysis Level 1 FAs include: non-destructive tests, optical inspection,](https://reader031.fdocuments.us/reader031/viewer/2022011802/5b2ac1697f8b9a980b8b48f6/html5/thumbnails/3.jpg)
Copyright © 2013 EAG, Inc. AN469 08.13 EAG.COM
Level 1 Failure Analysis
2015 M-009316 06.15
To discuss EAG’s capabilities, contact EAG’s commercial team at http://www.eag.com/contact/ or by phone at +1 800 366 3867.
DECAPSULATION
Full boil out to remove all the encapsulation material Using drop method to preserve encapsulation material and protect leads