Lenovo ThinkSystem DB400D and DB800D 32Gb FC...

33
Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors Product Guide The Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors combine innovative hardware, software, and integrated network sensors to ensure the highest levels of operational stability and application performance. Designed to enable maximum flexibility and reliability, the Lenovo FC SAN directors deliver market-leading 32 Gb Gen 6 Fibre Channel technology with modular building blocks for increased scalability to accommodate growth for large-scale enterprise infrastructures. The Lenovo FC SAN Directors provide full non-blocking performance with scalability of up to four (DB400D) or eight (DB800D) port blades to deliver up to 192x (DB400D) or 384x (DB800D) FC SFP+ ports that support 4/8/10/16/32 Gbps speeds. The Lenovo FC SAN Directors also offer FC over IP extension capabilities with support for up to 8x 40 GbE QSFP+ ports and up to 64x 1/10 GbE SFP+ ports with up to four extension blades. The Lenovo FC SAN Directors provide 16x (DB400D) or 32x (DB800D) FC QSFP+ ports that support 4x 16/32 Gbps speeds and can be used for inter-chassis connectivity. The following figure shows the Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors. Figure 1. Lenovo ThinkSystem DB400D (Left) and DB800D (Right) 32Gb FC SAN Directors Did you know? The DB400D and DB800D 32Gb FC SAN Directors leverage storage connectivity technologies from Brocade, a leader in Fibre Channel networking. Fabric Vision technology, an extension of Gen 6 Fibre Channel, provides unprecedented insight and visibility across the SAN with powerful built-in monitoring, management, and diagnostic tools. With Lenovo FC SAN Switch offerings, Lenovo can be your trusted partner that offers "one stop shop" and single point of contact for delivery of leading edge technologies and innovations from Lenovo and other leading IT vendors. These offerings can satisfy the wide range of your end-to-end IT infrastructure needs, including end-user devices, servers, storage, networking, services, management software, and financing. Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 1

Transcript of Lenovo ThinkSystem DB400D and DB800D 32Gb FC...

Page 1: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

Lenovo ThinkSystem DB400D and DB800D 32Gb FCSAN DirectorsProduct Guide

The Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors combine innovative hardware,software, and integrated network sensors to ensure the highest levels of operational stability and applicationperformance. Designed to enable maximum flexibility and reliability, the Lenovo FC SAN directors delivermarket-leading 32 Gb Gen 6 Fibre Channel technology with modular building blocks for increased scalabilityto accommodate growth for large-scale enterprise infrastructures.The Lenovo FC SAN Directors provide full non-blocking performance with scalability of up to four (DB400D)or eight (DB800D) port blades to deliver up to 192x (DB400D) or 384x (DB800D) FC SFP+ ports that support4/8/10/16/32 Gbps speeds. The Lenovo FC SAN Directors also offer FC over IP extension capabilities withsupport for up to 8x 40 GbE QSFP+ ports and up to 64x 1/10 GbE SFP+ ports with up to four extensionblades. The Lenovo FC SAN Directors provide 16x (DB400D) or 32x (DB800D) FC QSFP+ ports that support4x 16/32 Gbps speeds and can be used for inter-chassis connectivity.The following figure shows the Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors.

Figure 1. Lenovo ThinkSystem DB400D (Left) and DB800D (Right) 32Gb FC SAN Directors

Did you know?The DB400D and DB800D 32Gb FC SAN Directors leverage storage connectivity technologies from Brocade,a leader in Fibre Channel networking.Fabric Vision technology, an extension of Gen 6 Fibre Channel, provides unprecedented insight and visibilityacross the SAN with powerful built-in monitoring, management, and diagnostic tools.With Lenovo FC SAN Switch offerings, Lenovo can be your trusted partner that offers "one stop shop" andsingle point of contact for delivery of leading edge technologies and innovations from Lenovo and otherleading IT vendors. These offerings can satisfy the wide range of your end-to-end IT infrastructure needs,including end-user devices, servers, storage, networking, services, management software, and financing.

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 1

Page 2: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

Key featuresThe ThinkSystem DB400D and DB800D 32Gb FC SAN Directors offer the following features and benefits:

Enhance operational stability, maximize application performance, and increase business agility withenterprise-class Gen 6 FC SAN directorsConsolidate infrastructure with 128 Gbps inter-chassis connectivity for simpler, flatter, low-latencyfabrics.Enable “pay-as-you-grow” scalability with full-fabric enterprise capabilities from 48 to 192 (DB400D)or 384 (DB800D) 32 Gb FC ports.Optimize fabric behavior and ensure sufficient bandwidth for mission-critical applications withadvanced traffic management capabilities and adaptive networking.Extend replication over distance with a highly scalable extension solution for Fibre Channel, IP, andFICON.Protect existing device investments with auto-sensing 4, 8, 16, and 32 Gbit/sec capabilities andnative operation with Brocade fabrics.Simplify end-to-end management of large-scale environments by automating monitoring anddiagnostics.Run Fabric OS, which delivers distributed intelligence throughout the network and enables a widerange of value-added features.Leverage Fabric Vision technology’s powerful monitoring, management, and diagnostic tools tosimplify administration, increase uptime, and reduce costs.Provides proactive, non-intrusive, real-time monitoring and alerting of VM health and performancewith VM Insight through integrated network sensors.Supply a rich set of standard features at no extra cost, including fabric services, advanced zoning,adaptive networking, integrated 10 Gb FC, diagnostic tools, ISL trunking, advanced monitoring andalerting, long-distance fabrics, and FICON CUP.Expand fabric capabilities with optional licensed functions, including Inter-Chassis Links (ICLs) andFC-FC routing.Compress and encrypt in-flight data on up to four ports for more efficient link utilization and bettersecurity.Virtualize physical FC SAN switches and fabrics into logical entities for better flexibility, utilization,management, and efficiency.Allow organizations to seamlessly integrate Gen 6 Fibre Channel networks with the next generation offlash storage – NVMe over Fibre Channel – by being NVMe-ready, without a disruptive rip and replace,to achieve faster application response times and harness the performance of solid state drives forbetter scalability across virtual data centers with flash storage.Designed to provide 99.999% uptime capabilities and maximize resiliency with redundant hot-swapcomponents, including power supplies, cooling modules, blades, transceivers, online diagnostics, andnon-disruptive firmware download and activation.Accelerate troubleshooting with built-in advanced diagnostics tools featuring ClearLink Diagnosticswith D_Ports and select adapters from QLogic and Emulex.

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 2

Page 3: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

Components and connectorsThe following figure shows the port-side view of the DB400D 32Gb FC SAN Director.

Figure 2. DB400D 32Gb FC SAN Director port-side viewThe port side of the DB400D chassis has the following components:

Two redundant hot-swap active/standby Control Processor blades (CP blades come with the chassis)A Control Processor (CP) blade contains the control plane for the device and hosts the Fabric OS thatmanages all hardware within the device, and it provides the following external connections for deviceconfiguration, firmware downloads, service, management, and monitoring functions:

USB port for firmware download and technical support dataSerial console RJ-45 port10/100/1000 Mb Ethernet RJ-45 port for device management and configuration10/100/1000 Mb Ethernet RJ-45 port for service10 Gb Ethernet RJ-45 port (reserved for future use)

Note: The two 10/100/1000 Mb Ethernet ports are configured in an active/standby pair.Two redundant hot-swap active/active Core Routing CR32-4 blades (CR blades come with thechassis)Core routing blades contain ASICs that allow switching between up to four port blades, and each corerouting blade provides 96 Fibre Channel backplane ports for port or expansion blade connections and32 front-end FC links that are mapped to 8 QSFP+ ports for inter-chassis links (ICLs).Four hot-swap slots for port blades and expansion blades (Blades must be ordered together with thechassis)

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 3

Page 4: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

The following figure shows the non-port side view of the DB400D 32Gb FC SAN Director.

Figure 3. DB400D 32Gb FC SAN Director non-port side viewThe non-port side of the DB400D chassis has the following components:

Two hot-swap power supplies (must be ordered together with the chassis)Two hot-swap cooling modules (must be ordered together with the chassis)

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 4

Page 5: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

The following figure shows the port-side view of the DB800D 32Gb FC SAN Director.

Figure 4. DB800D 32Gb FC SAN Director port-side viewThe port side of the DB800D chassis has the following components:

Two redundant hot-swap active/standby Control Processor blades (CP blades come with the chassis)A Control Processor (CP) blade contains the control plane for the device and hosts the Fabric OS thatmanages all hardware within the device, and it provides the following external connections for deviceconfiguration, firmware downloads, service, management, and monitoring functions:

USB port for firmware download and technical support dataSerial console RJ-45 port10/100/1000 Mb Ethernet RJ-45 port for device management and configuration10/100/1000 Mb Ethernet RJ-45 port for service10 Gb Ethernet RJ-45 port (reserved for future use)

Note: The two 10/100/1000 Mb Ethernet ports are configured in an active/standby pair.Two redundant hot-swap active/active Core Routing CR32-8 blades (CR blades come with thechassis)Core routing blades contain ASICs that allow switching between up to eight port blades, and eachcore routing blade provides 192 Fibre Channel backplane ports for port or expansion bladeconnections and 64 front-end FC links that are mapped to 16 QSFP+ ports for inter-chassis links(ICLs).Eight hot-swap slots for port blades and expansion blades (Blades must be ordered together with thechassis)

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 5

Page 6: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

The following figure shows the non-port side view of the DB800D 32Gb FC SAN Director.

Figure 5. DB800D 32Gb FC SAN Director non-port side viewThe non-port side of the DB800D chassis has the following components:

Three or four hot-swap power supplies (must be ordered together with the chassis)Three hot-swap cooling modules (must be ordered together with the chassis)

The following figure shows the FC32-48 port blade.

Figure 6. FC32-48 port bladeThe FC32-48 port blade contains 48 ports capable of Fibre Channel speeds up to 32 Gbps. The FC32-48port blade enables high density Gen 6 SAN configurations supporting up to 192 32-Gbps external ports in asingle DB400D chassis, and up to 384 32-Gbps external ports in a single DB800D chassis.

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 6

Page 7: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

The following figure shows the SX6 extension blade.

Figure 7. SX6 extension bladeThe SX6 Extension blade is intended as an extension platform to support Fibre Channel, FICON, and IPbased storage data flows. Extension features enable you to use the existing IP wide area network (WAN)infrastructure to connect Fibre Channel and IP fabrics. Extension features support applications such asremote data replication (RDR), centralized backup, and data migration over very long distances. Extensiontunnels, built on a physical connection between two extension switches or blades, allow Fibre Channel andIP I/O to pass through the IP WAN. The SX6 Extension blade can connect with an SX6 blade in anotherDB400D or DB800D 32Gb FC SAN Director or with a Brocade 7840 Extension Switch.

System specificationsThe following table lists the ThinkSystem DB400D and DB800D 32Gb FC SAN Director systemspecifications.

Table 1. ThinkSystem DB400D and DB800D 32Gb FC SAN Director system specifications

ComponentSpecificationDB400D DB800D

Form factor 8U rack mount (Machine Type 6684) 14U rack mount (Machine Type 6682)Blades 2x Redundant control processor blades

2x Redundant CR32-4 core routing blades4x slots for port and expansion blades:

Up to 4x FC32-48 port bladesUp to 4x SX6 extension blades

2x Redundant Control processor blades2x Redundant CR32-8 core routing blades8x slots for port and expansion blades:

Up to 8x FC32-48 port bladesUp to 4x SX6 extension blades

Ports CR32-4 core routing blade:8x 64/128 Gb FC QSFP+ ports

CR32-8 core routing blade:16x 64/128 Gb FC QSFP+ ports

FC32-48 port blade:48x 4/8/10/16/32 Gb FC SFP+ ports

SX6 extension blade:16x 4/8/10/16/32 Gb FC SFP+ ports16x 1/10 Gb Ethernet SFP+ ports2x 40 Gb Ethernet QSFP+ ports

Media types Fibre Channel transceivers:128 Gb (4x 32 Gb) FC QSFP+: short-wavelength (SWL).4x 16 Gb FC QSFP+: SWL, long-wavelength (LWL).32 Gb FC SFP+: SWL, LWL.16 Gb FC SFP+: SWL, LWL, extended long-wavelength (ELWL).10 Gb FC SFP+: SWL, LWL.

Ethernet transceivers:40 GbE QSFP+: short-range (SR4), long-range (LR4), extended range (ER4).10 GbE SFP+: short-range (SR), long-range (LR), Dense Wavelength DivisionMultiplexing (DWDM).1 GbE SFP: short-wavelength (SX), long-wavelength (LX), RJ-45 unshielded twistedpair (UTP).

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 7

Page 8: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

Port speeds Fibre Channel transceivers:128 Gb (4x 32 Gb) FC QSFP+: 4x 32 Gbps fixed.4x 16 Gb FC QSFP+: 4x 16 Gbps fixed.32 Gb FC SFP+: 32/16/8 Gbps auto-sensing.16 Gb FC SFP+: 16/8/4 Gbps auto-sensing.10 Gb FC SFP+: 10 Gbps fixed.

Ethernet transceivers:40 GbE QSFP+: 40 Gbps fixed10 GbE SFP+: 10 Gbps fixed1 GbE SFP: 1 Gbps fixed

FC porttypes

FC32-48 port blade:F_Port, E_Port, EX_Port (Requires an optional Integrated Routing License), M_Port(Mirror Port), D_Port (Diagnostic Port).

SX6 extension blade:F_Port, FL_Port, E_Port, EX_Port (FC), VE_Port (Ethernet) (EX_Port and VE_Portrequire an optional Integrated Routing License).

Core routing blades (CR32-4 and CR32-8):E_Port, EX_Port (EX_Port requires an optional Integrated Routing License).

Data traffictypes

Unicast (Class 2 and Class 3), multicast (Class 3 only), broadcast (Class 3 only).

Classes ofservice

Class 2, Class 3, Class F (inter-switch frames).

Standardsoftware

Full Fabric, Advanced Zoning, Fabric Services, 10 Gb FC, Adaptive Networking, AdvancedDiagnostic Tools, Virtual Fabrics, In-flight Compression, In-flight Encryption, ISL Trunking, FabricVision, Extended Fabric, FICON CUP.

Optionalsoftware

Inter-Chassis Links (ICLs), Integrated Routing.

Performance Non-blocking architecture with wire-speed forwarding of FC traffic:4GFC: 4.25 Gbit/sec line speed, full duplex8GFC: 8.5 Gbit/sec line speed, full duplex10GFC: 10.51875 Gbit/sec line speed, full duplex16GFC: 14.025 Gbit/sec line speed, full duplex32GFC: 28.05 Gbit/sec line speed, full duplex

Cut-through FC switching:Up to 0.9 µs local switching latency (including FEC)Up to 2.7 µs blade-to-blade switching latency (including FEC)

Aggregatedthroughput

8 Tbps 16 Tbps

Scalability Maximum number of switches in the fabric: 239Maximum frame size: 2,112-byte payloadMaximum number of frame buffers per switching ASIC: 15,000Maximum number of ports per ISL trunk: 8x SFP+

Cooling 2x Cooling modules required; each modulecontains two fans. N+1 (3+1) fan redundancy.Non-port to port side airflow.

3x Cooling modules required; each modulecontains two fans. N+1 (5+1) fan redundancy.Non-port to port side airflow.

Powersupply type

Hot-swap 1450 W (100 - 120 V AC) / 2870 W (200 - 240 V AC) power supply (IEC 309-C20connector).

ComponentSpecificationDB400D DB800D

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 8

Page 9: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

Powersupplyquantity

2 required 3 required; 4 maximum

Hot-swapparts

Blades, SFP+/QSFP+ transceivers, power supplies, cooling modules.

Managementports

Per control processor blade:2x 10/100/1000 Mb Ethernet ports (UTP, RJ-45); 1x RS-232 port (RJ-45); 1x USB port (foradditional firmware/log/configuration files storage).

Managementinterfaces

Web-based GUI (Web Tools); Command Line Interface (CLI); SMI-S; SNMP; REST API. OptionalBrocade Network Advisor.

Securityfeatures

Secure Socket Layer (SSL); Secure Shell (SSH); Secure Copy (SCP); Secure FTP (SFTP); user levelsecurity, Role-based Access Control (RBAC); LDAP, RADIUS, and TACACS+ authentication; accesscontrol lists (ACLs); IP security (IPsec).

Hardwarewarranty

One-year customer-replaceable unit limited warranty with 9x5 next business day partsdelivered. Optional warranty service upgrades are available through Lenovo: on-site coverage(technician installed parts), 24x7 coverage, 24-hour response time, 1-year or 2-year warrantyextensions, Remote Technical Support.

Softwaremaintenance

Three-year software support and subscription license is included.

Dimensions Height: 345 mm (13.6 in.)Width: 437 mm (17.2 in.)Depth: 611 mm (24.0 in.)

Height: 612 mm (24.1 in.)Width: 437 mm (17.2 in.)Depth: 611 mm (24.0 in.)

Weight Empty: 24.5 kg (54.0 lb)Fully configured: 69.0 kg (152.0 lb).

Empty: 35.6 kg (78.5 lb)Fully configured: 145.8 kg (321.5 lb).

ComponentSpecificationDB400D DB800D

ModelsThe following table lists the DB400D and DB800D 32Gb FC SAN Director models.

Table 2. DB400D and DB800D 32Gb FC SAN Director models

DescriptionPartnumber

Machine Type-Model

Featurecode

Lenovo ThinkSystem DB400D 32Gb FC Director, Up to 192 ports, 8U,Enterprise SW

6684B2A 6684-HC1 AVK7

Lenovo ThinkSystem DB800D 32Gb FC Director, Up to 384 ports, 14U,Enterprise SW

6682B1A 6682-HC1 AVGJ

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 9

Page 10: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

The DB400D and DB800D 32Gb FC SAN Director part numbers include the following items:One 32 Gb FC Director chassis that contains the following components:

Two control bladesTwo core routing blades

Chassis doorSerial cable (DB-9/RJ-45 to RJ-45)SFP extraction toolPower cord retainer clipsCable management assembly4 GB USB driveAdjustable rack mount kitGround lug kitOnline Documentation web pointer cardNetwork Advisor web pointer card

Notes:The ThinkSystem DB400D and DB800D models come standard without port or expansionblades; they should be ordered for the director model (See Blades for details)The ThinkSystem DB400D and DB800D models come standard without fan modules and powersupplies; at least a minimum quantity required must be ordered together with the director model (SeeCooling and Power supplies and cables for details).The ThinkSystem DB400D and DB800D models come standard without power cords; they must beordered together with the switch (see Power supplies and cables for details).

BladesThe DB400D and DB800D 32Gb FC SAN Directors support the port and extension blade options that arelisted in the following table.

Table 3. Port and extension blades

DescriptionPartnumber

Featurecode

QuantityDB400D DB800D

Port bladesLenovo Gen 6 Port Blade FC32-48 (no transceivers) 01KN845 AVGT 4 8Lenovo Gen 6 Port Blade FC32-48 (48 transceivers, 32Gbps) 01KN848 AVGU 4 8Extension bladesLenovo SX6 FC-IP SAN extension blade + 16 32Gb SWL SFPs 01KN850 AVGV 4 4Lenovo SX6 FC-IP SAN extension blade + 16 32Gb LWL SFPs 01KN854 AVGW 4 4

Port and extension blades come standard with all ports activated, and certain part numbers also includeSFP+ transceivers. Additional transceivers and cables can be ordered, if required (See Transceivers andcables for details).

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 10

Page 11: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

Transceivers and cablesWith the flexibility of the DB400D and DB800D 32Gb FC SAN Directors, customers can choose the followingconnectivity technologies:

SFP+ ports on the port blades and expansion bladesFor 32 Gb FC links, customers can use 32 Gb FC SFP+ SW optical transceivers for distancesup to 100 meters on 50 µ OM4 multimode fiber optic cables. For longer distances, the 32 GbFC LW SFP+ optical transceivers can support up to 10 kilometers on 9 µ single-mode fiberoptic cables. These transceivers can operate at 32 Gbps, 16 Gbps, or 8 Gbps speeds.For 16 Gb FC links, customers can use 16 Gb FC SFP+ SW optical transceivers for distancesup to 125 meters on 50 µ OM4 multimode fiber optic cables. For longer distances, the 16 GbFC LW SFP+ optical transceivers can support up to 10 kilometers on 9 µ single-mode fiberoptic cables. For extended distances, the 16 Gb FC ELW SFP+ optical transceivers cansupport up to 25 kilometers on 9 µ single-mode fiber optic cables. These transceivers canoperate at 16 Gbps, 8 Gbps, or 4 Gbps speeds.For 10 Gb FC links, customers can use 10 Gb FC SFP+ SW transceivers for distances up to550 meters on 50 µ OM4 multimode fiber optic cables, or 10 Gb FC SFP+ LW transceivers fordistances up to 10 km on 9 µ single-mode fiber optic cables. 10 Gb FC operations allow metroconnectivity by directly utilizing a fiber optic cable between sites or by creating multiplechannels on an optical cable between sites, utilizing Wave Division Multiplexing (WDM)technology.

QSFP+ ports on the core routing blades:For 128 Gb FC inter-chassis links for connectivity between the DB400D or DB800D 32Gb FCDirectors, customers can use 128 Gb (4x 32 Gb) FC QSFP+ SW optical transceiversfor distances up to 100 meters on 50 µ OM4 multimode fiber optic cables.Note: ICL trunks are formed automatically with corresponding 32 Gbps ports on differentQSFP+ transceivers (ICL trunks cannot be formed with the 4x32 Gbps ports on the sameQSFP+ transceiver), and the trunking license is not required.For 64 Gb FC inter-chassis links for connectivity between the DB400D or DB800D 32Gb FCDirectors and Brocade DCX 8510 Backbones, customers can use 4x 16 Gb FC QSFP+ SWLoptical transceivers for distances up to 100 meters on 50 µ OM4 multimode fiber optic cables.For longer distances, the 4x 16 Gb FC QSFP+ LWL optical transceivers can support distancesup to 2 kilometers on parallel 9 µ single mode fiber cables.Note: ICL trunks are formed automatically with corresponding 16 Gbps ports on differentQSFP+ transceivers (ICL trunks cannot be formed with the 4x16 Gbps ports on the sameQSFP+ transceiver), and the trunking license is not required.

1/10 GbE SFP+ and 40 GbE QSFP+ ports on extension blades allow connection to IP WANs andallow Fibre Channel and IP I/O traffic to pass through the IP WAN through extension tunnels.

For 1 GbE links, customers can use RJ-45 SFP transceivers with UTP cables up to 100 meters.Customers that need longer distances can use a 1000BASE-SX transceiver, which can drivedistances up to 220 meters with 62.5 µ OM1 and up to 550 meters on 50 µ OM2 multimodefiber optic cables, or the 1000BASE-LX transceivers that support distances up to 10 kilometerson 9 µ single-mode fiber optic cables.For 10 GbE links, customers can use a 10GBASE-SR transceiver that supports distances up to300 meters over OM3 or up to 400 meters over OM4 multimode fiber optic cables. For longerdistances, the 10GBASE-LR transceivers can support distances up to 10 kilometers on 9 µsingle mode fiber cables.For distances up to 80 km, customers can use the 10GBASE-ZRD Tunable DWDM opticaltransceiver on 9 µ single-mode fiber optic cables.For 40 GbE links, customers can use the 40GBASE-SR4 QSFP+ transceivers for distances upto 100 meters with OM3 or up to 150 meters with OM4 multimode fiber cables. For longerdistances, the 40GBASE-LR4 transceivers can support distances up to 10 kilometers on 9 µsingle mode fiber cables. For extended distances, the 40GBASE-ER4 transceivers can supportdistances up to 40 kilometers on 9 µ single mode fiber cables.

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 11

Page 12: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

The FC32-48 port blades come standard with or without 48x 32 Gb FC SWL SFP+ transceivers, and the SX6extension blades come standard with 16x 32 Gb FC SWL or LWL SFP+ transceivers. The optional ICLbundles include 8x or 16x 128 Gb FC or 64 Gb FC QSFP+ transceivers. Additional Fibre Channel or EthernetSFP+ and QSFP+ transceivers can be ordered, if required.The following table lists the supported SFP+ and QSFP+ transceiver options and optical cables.

Table 4. SFP+ and QSFP+ transceivers and optical cables

DescriptionPartnumber

Featurecode

Maximum quantity supported

Per bladePerchassis

QSFP+ transceiversBrocade 128Gb (4x32Gb) SWL QSFP+ Transceiver 01KN801 AVGG - - 8 16 16 32Brocade 4x16Gb FC-Compliant SWL QSFP+ Transceiver 01KN805 AVGH - - 8 16 16 32Brocade 4x16Gbps 2km LWL QSFP+ Transceiver 01KN809 AVGK - - 8 16 16 3232 Gb FC SFP+ transceivers Brocade 32Gb SWL SFP+ Transceiver 01KN789 AVGC 48 16 - - 192 384Brocade 32Gb SWL SFP+ Transceiver (8-pack) 01KN793 AVGD 6 2 - - 24 48Brocade 32Gb LWL SFP+ Transceiver 01KN795 AVGE 48 16 - - 192 384Brocade 32Gb LWL SFP+ Transceiver (8-pack) 01KN799 AVGF 6 2 - - 24 4816 Gb FC SFP+ transceiversBrocade 16Gb SWL SFP+ Optical Transceiver 88Y6393 A22R 48 16 - - 192 384Brocade 16Gb 10km LWL SFP+ Transceiver 00MY768 ASK2 48 16 - - 192 384Brocade 16Gb 25km ELWL SFP+ Transceiver 00MY770 ASK3 48 16 - - 192 38410 Gb FC SFP+ transceiversBrocade 10Gb FC SWL SFP+ Transceiver 00YH933 ATSY 48 16 - - 192 384Brocade 10Gb FC LWL SFP+ Transceiver 00YH929 ATSX 48 16 - - 192 38440 Gb Ethernet QSFP+ transceiversBrocade 40Gb QSFP+ SR4 Optical Transceiver 01KN813 AVGL - 2 - - 8 8Brocade 40Gb QSFP+ LR4 Optical Transceiver 01KN817 AVGM - 2 - - 8 8Brocade 40Gb QSFP+ ER4 Optical Transceiver 01KN821 AVGN - 2 - - 8 810 Gb Ethernet SFP+ transceiversBrocade 10Gb SFP+ SR Optical Transceiver 49Y4216 0069 - 16 - - 64 64Brocade 10Gb SFP+ LR Optical Transceiver 95Y0540 A3AB - 16 - - 64 64Brocade 10GBASE-ZRD DWDM 80km SFP+ Transceiver 01KN837 AVGS - 16 - - 64 641 Gb Ethernet SFP transceiversBrocade 1000BASE-SX SFP Transceiver 01KN825 AVGP - 16 - - 64 64Brocade 1000BASE-LX SFP Transceiver 01KN829 AVGQ - 16 - - 64 64Brocade 1000BASE-T SFP Transceiver 01KN833 AVGR - 16 - - 64 64Optical cables for 16 Gb and 32 Gb FC SWL and 1/10 GbE SFP+ optical transceiversLenovo 0.5m LC-LC OM3 MMF Cable 00MN499 ASR5 48 16 - - 192 384

FC32

-48

SX6

CR32

-4

CR32

-8

DB40

0D

DB80

0D

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 12

Page 13: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

Lenovo 1m LC-LC OM3 MMF Cable 00MN502 ASR6 48 16 - - 192 384Lenovo 3m LC-LC OM3 MMF Cable 00MN505 ASR7 48 16 - - 192 384Lenovo 5m LC-LC OM3 MMF Cable 00MN508 ASR8 48 16 - - 192 384Lenovo 10m LC-LC OM3 MMF Cable 00MN511 ASR9 48 16 - - 192 384Lenovo 15m LC-LC OM3 MMF Cable 00MN514 ASRA 48 16 - - 192 384Lenovo 25m LC-LC OM3 MMF Cable 00MN517 ASRB 48 16 - - 192 384Lenovo 30m LC-LC OM3 MMF Cable 00MN520 ASRC 48 16 - - 192 384

DescriptionPartnumber

Featurecode

Maximum quantity supported

Per bladePerchassis

The following table lists the cabling requirements for the switch.

Table 5. DB400D and DB800D 32Gb FC SAN Director cabling requirementsTransceiver Standard Cable Connector128 Gb (4x 32 Gb) Fibre Channel128 Gb (4x 32 Gb) FCSWL QSFP+ (01KN801)

FC-PI-6 850 nm 50 µ multi-mode fiber optic cable:32GFC: Up to 100 m (OM4) or up to 70 m (OM3)

MPO

64 Gb (4x 16 Gb) Fibre Channel4x 16 Gb FC SWLQSFP+ (01KN805)

FC-PI-5 850 nm 50 µ multi-mode fiber optic cable:16GFC: Up to 100 m (OM4) or up to 66 m (OM3)

MPO

4x 16 Gb FC LWLQSFP+ (01KN809)

FC-PI-5 Parallel 1310 nm 9 µ single-mode fiber optic cables:16GFC: Up to 2 km

MPO

32 Gb Fibre Channel32 Gb FC SWL SFP+(01KN789, 01KN793)

FC-PI-6 Up to 30 m with fiber optic cables supplied by Lenovo (seeTable 4).

850 nm 50 µ multi-mode fiber optic cable:32GFC: Up to 100 m (OM4) or up to 70 m (OM3)16GFC: Up to 125 m (OM4) or up to 100 m (OM3)8GFC: Up to 190 m (OM4) or up to 150 m (OM3)

LC

32 Gb FC LWL SFP+(01KN795, 01KN799)

FC-PI-6 1310 nm 9 µ single-mode fiber optic cable:32GFC, 16GFC, 8GFC: Up to 10 km

LC

16 Gb Fibre Channel16 Gb FC SWL SFP+(88Y6393)

FC-PI-5 Up to 30 m with fiber optic cables supplied by Lenovo (seeTable 4).

850 nm 50 µ multi-mode fiber optic cable:16GFC: Up to 125 m (OM4) or up to 100 m (OM3)8GFC: Up to 190 m (OM4) or up to 150 m (OM3)4GFC: Up to 400 m (OM4) or up to 380 m (OM3)

LC

16 Gb FC LWL SFP+(00MY768)

FC-PI-5 1310 nm 9 µ single-mode fiber optic cable:16GFC, 8GFC: Up to 10 km4GFC: Up to 30 km

LC

FC32

-48

SX6

CR32

-4

CR32

-8

DB40

0D

DB80

0D

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 13

Page 14: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

16 Gb FC ELWL SFP+(00MY770)

FC-PI-5 1310 nm 9 µ single-mode fiber optic cable:16GFC: Up to 25 km

LC

10 Gb Fibre Channel10 Gb FC SWL SFP+(00YH933)

FC-10GFC 850 nm 50 µ multi-mode fiber optic cable:10GFC: Up to 550 m (OM4) or up to 300 m (OM3)

LC

10 Gb FC LWL SFP+(00YH929)

FC-10GFC 1310 nm 9 µ single-mode fiber optic cable:10GFC: Up to 10 km

LC

40 Gb Ethernet40 GbE SR4 SFP+(01KN813)

40GBASE-SR4 850 nm 50 µ multi-mode fiber optic cable:Up to 150 m (OM4) or up to 100 m (OM3)

MPO

40 GbE LR4 SFP+(01KN817)

40GBASE-LR4 1310 nm 9 µ single-mode fiber optic cable up to 10 km LC

40 GbE ER4 SFP+(01KN821)

40GBASE-ER4 1310 nm 9 µ single-mode fiber optic cable up to 40 km LC

10 Gb Ethernet10 GbE SR SFP+(49Y4216)

10GBASE-SR Up to 30 m with fiber optic cables supplied by Lenovo (seeTable 4).

850 nm 50 µ multi-mode fiber optic cable:Up to 400 m (OM4) or up to 300 m (OM3)

LC

10 GbE LR SFP+(95Y0540)

10GBASE-LR 1310 nm 9 µ single-mode fiber optic cable up to 10 km LC

10 GbE DWDM SFP+(01KN837)

10GBASE-ZRD 1550 nm 9 µ single-mode fiber optic cable up to 80 km LC

1 Gb Ethernet1 GbE SX SFP(01KN825)

1000BASE-SX Up to 30 m with fiber optic cables supplied by Lenovo (seeTable 4).

850 nm 50 µ multi-mode fiber optic cable up to 550 m

LC

1 GbE LX SFP(01KN829)

1000BASE-LX 1310 nm 9 µ single-mode fiber optic cable up to 10 km LC

1 GbE RJ-45 SFP(01KN833)

1000BASE-T UTP Category 5, 5E, and 6 up to 100 meters RJ-45

Management ports10/100/1000 MbEthernet managementport

1000BASE-T UTP Category 5, 5E, and 6 up to 100 meters RJ-45

Serial management port RS-232 DB-9/RJ-45-to-RJ-45 console cable (comes with thedirector)

RJ-45

Transceiver Standard Cable Connector

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 14

Page 15: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

SoftwareThe DB400D and DB800D 32Gb FC SAN Directors come standard with the following software features(based on Fabric OS 8.1):

Advanced Fabric ServicesFull Fabric mode: Enables high performance 16 Gb or 32 Gb switching in multi-switch fabric.Advanced Zoning (default zoning, port/WWN zoning, broadcast zoning)Dynamic fabric provisioning (DFP): Fabric-assigned port World Wide Names (FA-PWWNs).Dynamic path selection (DPS): Distributes input traffic across multiple paths proportionally tothe bandwidth of each path.Dynamic load sharing (DLS): Distributes traffic across multiple equivalent paths betweenswitches.Fabric Shortest Path First (FSPF)Buffer-to-Buffer (BB) credit flow controlBuffer credit recoveryForward error correction (FEC)Fabric Device Management Interface (FDMI)Frame order deliveryFrame redirectionFC login servicesRegistered State Change Notification (RSCN)Reliable Commit Service (RCS)Simple Name Server (SNS)Fibre Channel Authentication Protocol (FCAP) switch authenticationManagement Server (MS): Assists in the auto-discovery of switch-based fabrics.In-flight compression on up to 4 portsIn-flight encryption on up to 4 portsIntegrated 10Gb FC feature: Allows 10 Gb FC operations for metro connectivityISL Trunking: Allows frame-based consolidation of up to 8 inter-switch links (ISLs) into fault-tolerant and load-balanced trunks with bandwidth of up to 256 Gbps.Fabric Vision

Monitoring and Alerting Policy Suite (MAPS): Provides a policy-based, fabric-widethreshold monitoring and alerting tool.Flow Vision: Allows to identify, monitor, and analyze specific application flows.VM Insight: Allows to monitor health and performance of individual Virtual Machines(VMs) to quickly identify abnormal VM behavior and enable administrators to proactivelyfacilitate troubleshooting and fault isolation, helping to ensure performance andoperational stability.

Extended Fabric: Extends Fibre Channel SANs beyond 10 km distance limitations forreplication and backup at full bandwidth.Control Unit Port (CUP): Provides an in-band management interface that the FICON host(Mainframe) can use for managing and monitoring the FC SAN switches.

Adaptive NetworkingTraffic isolation zoning (TIZ): Creates a dedicated path for traffic flowing from a specific set ofsource ports (F_Ports).Quality of Service (QoS): SID/DID pair traffic prioritization (high, medium, low)

VirtualizationN_Port ID virtualization (NPIV): Enables a single FC port to appear as multiple, distinct portswith separate port identification within the fabric.Virtual Fabrics (Logical Switch, Logical Fabric): Allows SAN design and management at thegranularity of a port.

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 15

Page 16: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

Fibre Channel over IP and IP ExtensionIP WAN infrastructure for connecting Fibre Channel and IP fabrics802.1Q VLAN taggingStatic link aggregation (trunking)802.1p Class of Service (CoS) and IP DSCP traffic classification and processingIPv4 and IPv6 addressingAdaptive Rate Limiting (ARL)Traffic Control List (TCL) to manage and route IP flowsEthernet jumbo frames up to 9,216 bytes

ManagementIPv4 and IPv6 addressingFirmware upload and downloadHot code load and activationNetwork Time Protocol (NTP) v3EZ Switch Setup WizardCommand line interface (CLI)Web ToolsBrocade Network Advisor (purchased separately)SNMPv1, SNMPv3, and MIBsSMI-S compliantSyslog

SecurityLocal switch user accountsLDAP, RADIUS, TACACS+ user authenticationRole-based access control (RBAC)IP Security (IPsec)IP filteringHTTPSSecure Copy (SCP)Secure RPCSecure FTP (SFTP)Secure Shell (SSH) v2Secure Sockets Layer (SSL)Federal Information Processing Standards (FIPS) 140-2 L2-compliant

Advanced Diagnostic ToolsPower-on self-test (POST)Event loggingEnvironmental monitoringFCpingPathinfo (FC traceroute)Non-disruptive daemon restartFlow mirroringRAS trace loggingClearLink Diagnostics with Diagnostic Port (D_Port): Helps ensure optical and signal integrityfor 16 Gb and 32 Gb Fibre Channel optics and cables.SFP and cable health assessmentPower monitoringRolling Reboot Detection (RRD)

The following optional software features are available for the Lenovo FC SAN Directors:Inter-Chassis Link (ICL): Allows to interconnect up to eight ThinkSystem DB400D or DB800D, or acombination of both, or connect ThinkSystem DB400D or DB800D to Brocade DCX8510 Backbones by using the QSFP+ ports on the core routing blades.Integrated Routing: The FC-FC routing service provides Fibre Channel routing between two or morefabrics without merging those fabrics.

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 16

Page 17: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

The following table lists ordering information for the optional software features and bundles for the DB400Dand DB800D 32Gb FC SAN Directors.

Table 6. Optional software features and bundles

DescriptionPartnumber

Featurecode

Maximumquantitysupported

ThinkSystem DB400D bundles and licensesGen 6 Inter-Chassis Link Lic + 8x (4x32Gb) QSFPs for DB400D 01KN865 AVK8 2Gen 5 Inter-Chassis Link Lic + 8x (4x16Gb) 100m QSFPs for DB400D 01KN868 AVK9 2Gen 5 Inter-Chassis Link Lic + 8x (4x16Gb) 2km QSFPs for DB400D 01KN871 AVKA 2Lenovo DB400D/DB800D S/W, Integrated Routing 01KN889 AVH3 1ThinkSystem DB800D bundles and licensesGen 6 Inter-Chassis Link Lic + 16x (4x32Gb) QSFPs for DB800D 01KN862 AVK6 2Gen 5 Inter-Chassis Link Lic + 16x (4x16Gb) 100m QSFPs for DB800D 01KN856 AVGZ 2Gen 5 Inter-Chassis Link Lic + 8x (4x16Gb) 2km QSFPs for DB800D 01KN859 AVH0 2Lenovo DB400D/DB800D S/W, Integrated Routing 01KN889 AVH3 1

Each Inter-Chassis Link bundle includes Port on Demand (POD) licenses to activate a half of availableQSFP+ ports on both CR blades in the chassis, that is, each ICL license activates four ports on each CR32-4blade in the DB400D chassis and eight ports on each CR32-8 blade in the DB800D chassis.Each Inter-Chassis Link bundle also includes 8 (the DB400D bundles and the DB800D 2km QSFPs bundle) or16 (the DB800D bundles excluding the 2km QSFPs bundle) QSFP+ transceivers to populate the activatedQSFP+ ports.Software subscription and maintenance is included with the DB400D and DB800D 32Gb FC SAN Directorsand provides 3-year software support, including firmware downloads and fixes.Lenovo offers optional Brocade Network Advisor, a fabric management application, to efficiently manage thenetwork operations lifecycle, including monitoring, diagnostics, change management, and troubleshooting.Lenovo offers the following Brocade Network Advisor editions:

Brocade Network Advisor Professional Plus: A SAN management application designed for mid-sizedSANs for managing up to 36 physical or virtual fabrics and up to 2,560 switch ports.Brocade Network Advisor Enterprise: A SAN management application designed for enterprise-classSANs for managing up to 100 physical or virtual fabrics and up to 15,000 switch ports.

Brocade Network Advisor supports the a wide variety of Brocade SAN offerings, including Lenovo B300,B6505, B6510, DB620S, DB400D, DB800D, FC5022, and more. For a complete list of supported productsand edition features, refer to the Brocade Network Advisor Installation and Migration Guide:http://www.brocade.com/en/support/document-library/dl-segment-products-os-detail-page.bna.product.htmlThe following table lists ordering information for the optional Brocade Network Advisor licenses.

Table 7. Brocade Network Advisor licenses

DescriptionPartnumber

Featurecode

Brocade Network Advisor - SAN Professional Plus License 01KP108 AVK4Brocade Network Advisor - SAN Enterprise License 01KP105 AVK3Brocade Network Advisor - SAN Upgrade Prof. Plus to Enterprise Lic. 01KP111 AVK5

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 17

Page 18: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

Fibre Channel standardsThe DB400D and DB800D 32Gb FC SAN Directors support the following FC standards:

10GFC INCITS 364-2003 + Amendment 1FA FCMGMT-MIBFC-AL-2 INCITS 332-1999FC-BB-2 INCITS 372-2003FC-BB-3 INCITS 414-2006FC-BB-4 INCITS 419-2008FC-BB-5 INCITS 462-2010 + Amendment 1FC-BB-6 INCITS 509-2014FC-DA INCITS TR-36-2004FC-DA-2 INCITS TR-49-2012FC-FS INCITS 373-2003FC-FS-2 ANSI/INCITS 424-2006FC-FS-3 INCITS 470-2011FC-FS-4 INCITS 488 rev 1.41FC-GS-4 ANSI INCITS 387-2004FC-GS-5 ANSI INCITS 427-2007FC-GS-6 INCITS 463-2010FC-GS-7 INCITS 510FC-GS-8 INCITS 548 rev 11.01FC-IFR INCITS 475-2011FC-LS INCITS 433: 2007FC-LS-2 INCITS 477-2011FC-LS-3 INCITS 487FC-MI-2 ANSI/INCITS TR-39-2005FC-MI-3 INCITS TR-48-2012FCP ANSI X3.269-1996FCP-2 INCITS 350-2003FCP-3 INCITS 416-2006FCP-4 INCITS 481-2012FC-PI-3 INCITS 460-2012FC-PI-4 INCITS 450-2009FC-PI-5 INCITS 449-2011FC-PI-6 INCITS 512-2015FC-SB ANSI X3.271-1996FC-SB-2 INCITS 374-2001FC-SB-3 INCITS 374-2003 + Amendment 1FC-SB-4 INCITS 466-2011FC-SB-5 INCITS 485-2014FC-SB-6 INCITS 544FC-SP INCITS 426-2007FC-SP-2 INCITS 496-2012 + Amendment 1FC-SW-3 INCITS 384-2004FC-SW-4 INCITS 418-2006FC-SW-5 INCITS 461-2010FC-SW-6 INCITS 511FC-SW-7 INCITS 547 rev 1.04FC-TAPE INCITS TR-24-1999FC-VI INCITS 357-2002MIB-FA INCITS TR-32-2003RFC 2837 Fabric Element MIBRFC 4338 Transmission of IPv6, IPv4, and ARP over FCSNIA Storage Management Initiative Specification (SMI-S) Version 1.03 ISO standard IS24775-2006(replaces ANSI INCITS 388: 2004)SNIA Storage Management Initiative Specification Version 1.1

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 18

Page 19: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

SNIA Storage Management Initiative Specification Version 1.2SNIA Storage Management Initiative Specification Version 1.4SNIA Storage Management Initiative Specification Version 1.5SNIA Storage Management Initiative Specification Version 1.6

Ethernet standardsThe DB400D and DB800D 32Gb FC SAN Directors support the following Ethernet standards:

IEEE 802.1p Class of Service (CoS) prioritizationIEEE 802.1Q VLAN TaggingIEEE 802.3 10BASE-T Ethernet (CP management interfaces)IEEE 802.3u 100BASE-TX Fast Ethernet (CP management interfaces)IEEE 802.3z 1000BASE-SX short range fiber optics Gigabit EthernetIEEE 802.3z 1000BASE-LX long range fiber optics Gigabit EthernetIEEE 802.3ab 1000BASE-T copper twisted pair Gigabit EthernetIEEE 802.3ae 10GBASE-SR short range fiber optics 10 Gb EthernetIEEE 802.3ae 10GBASE-LR long range fiber optics 10 Gb EthernetIEEE 802.3ba 40GBASE-SR4 short range fiber optics 40 Gb EthernetIEEE 802.3ba 40GBASE-LR4 long range fiber optics 40 Gb EthernetIEEE 802.3bm 40GBASE-ER4 extended range fiber optics 40 Gb Ethernet10GBASE-ZRD DWDM fiber optics 10 Gb Ethernet

CoolingThe DB400D and DB800D 32Gb FC SAN Directors ship without cooling modules (fan assemblies); thecooling modules must be ordered together with the ThinkSystem DB400D and DB800D. Each coolingmodule has two integrated fans that provide non-port side air intake.Two cooling modules are required for the ThinkSystem DB400D, and three cooling modules are required forthe ThinkSystem DB800D. Cooling modules provide N + 1 fan redundancy (3 + 1 for the DB400D; 5 + 1 forthe DB800D), and the device can continue operation while one fan assembly is replaced if the fan assemblyis replaced immediately.The following table lists the cooling modules for the DB400D and DB800D 32Gb FC SAN Directors.

Table 8. Power supplies

DescriptionPartnumber

Featurecode

QuantityDB400D DB800D

FC SAN Director Fan Tray (Non-port side Intake forDB400D/DB800D)

01KN895 AVGY 2 3

Power supplies and cablesThe DB400D and DB800D 32Gb FC SAN Directors ship without power supplies; at least a minimum requiredquantity of the power supplies must be ordered together with the ThinkSystem DB400D and DB800D. Twopower supplies are required for the ThinkSystem DB400D, and a minimum of three power supplies isrequired for the ThinkSystem DB800D. The forth power supply can be added to the ThinkSystem DB800D toprovide additional power redundancy in certain configurations.The power supplies are hot-swap 1450 W (100 - 120 V AC) / 2870 W (200 - 240 V AC), and each powersupply has an IEC 320-C20 connector. Each power supply has two integrated fans that provide non-portside air intake that matches the airflow of the cooling modules.

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 19

Page 20: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

The following table lists the power supplies for the DB400D and DB800D 32Gb FC SAN Directors.

Table 9. Power supplies

DescriptionPartnumber

Featurecode

Quantity (min / max)DB400D DB800D

FC SAN Director PSU (Non-port side Intake for DB400D/DB800D) 01KN892 AVGX 2 / 2 3 / 4

The power supply redundancy depends on the blade and port configuration and the AC input voltage level,as shown in the following table.

Table 10. Power supply redundancy

Model

Powersupplyquantity Configured ports

Redundancy

100 - 120 V AC 200 - 240 V ACDB400D 2 Any combination of ports and QSFP ICLs No N + NDB800D 3 144x 32 Gbps ports and QSFP ICLs N+1 N + 2

Any combination of ports and QSFP ICLs No N + 14 144x 32 Gbps ports and QSFP ICLs N+N N + 3

Any combination of ports and QSFP ICLs No N + N

The FC SAN directors come standard without power cords; up to four rack power cables or country-specificline cords should be ordered for the FC SAN Directors depending on the quantity of power supplies.The following table lists rack power cords for the DB400D and DB800D 32Gb FC SAN Directors.

Table 11. Power cord options

DescriptionPartnumber

Featurecode

Rack power cables2.5m, 16A/100-240V, C19 to IEC 320-C20 Rack Power Cable 39Y7916 6252Country-specific line cords4.3m, 16A/120V, C19 to NEMA L5-20P (US) Line Cord 41Y9222 62744.3m, 16A/208V, C19 to NEMA L6-20P (US) Line Cord 40K9772 62754.3m, 16A/230V, C19 to IEC 309-P+N+G (Den/Sws) Line Cord 40K9769 62834.3m, 16A/230V, C19 to CEE7-VII (Europe) Line Cord 40K9766 62794.3m, 15A/230V, C19 to AS/NZS 3112 (Aus/NZ) Line Cord 40K9773 6284

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 20

Page 21: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

Rack installationThe DB400D and DB800D 32Gb FC SAN Directors come standard with the adjustable 27" to 31" rack mountkits that can be used for 4-post rack installations. The ThinkSystem DB400D also supports the optionalAirflow Diversion Kits that allow to divert the airflow from the side air vent to the port side. In addition, theLenovo DB800D supports 22" rack mount kit for specific racks.If required, the Lenovo FC SAN Directors can be mounted in a 2-post rack cabinet by using the optional mid-mount rack kits.The following table lists rack-mount options for the DB400D and DB800D 32Gb FC SAN Directors.

Table 12. Rack-mount options

DescriptionPartnumber

Featurecode

Maximumquantitysupported

ThinkSystem DB400D rack-mount optionsLenovo DB400D mid-mount rack kit 01KN874 AVKB 127-31" Airflow Diversion Kit for Lenovo DB400D 01KN877 AVKC 1*18-24" Airflow Diversion Kit for Lenovo DB400D 01KN880 AVKD 1*ThinkSystem DB800D rack-mount optionsLenovo DB800D 22" rack mount kit 01KN883 AVH1 1Lenovo DB800D mid-mount rack kit 01KN886 AVH2 1

* 27-31" and 18-24" Airflow Diversion Kits are mutually exclusive. Only one of these kits should be ordered, depending on thedepth of the rack cabinet.

The optional airflow diversion kit for the DB400D 32Gb FC Director is shown in the following figure.

Figure 8. DB400D Airflow Diversion Kit

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 21

Page 22: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

The optional mid-mount rack kits for the DB400D and DB800D 32Gb FC SAN Directors are shown in thefollowing figure.

Figure 9. ThinkSystem DB400D (Left) and DB800D (Right) Mid-mount Rack KitsIn addition, in order for the DB400D and DB800D 32Gb FC SAN Directors to meet FIPS 140-2 Level 2Physical Security requirements the tamper-evident seals must be installed (see the following table forordering information).

Table 13. Tamper-evident security seals

DescriptionPartnumber

Featurecode

Maximumquantitysupported

Brocade FIPS 140-2 High Security Labels and Seals 01KN785 AVGB 1

Physical specificationsThe DB400D and DB800D 32Gb FC SAN Directors have the following dimensions and weight (approximate):

Height:DB400D: 345 mm (13.6 in.)DB800D: 612 mm (24.1 in.)

Width: 437 mm (17.2 in.)Depth: 611 mm (24.0 in.)Weight:

DB400D:Empty: 24.5 kg (54.0 lb)Fully configured: 69.0 kg (152.0 lb)

DB800D:Empty: 35.6 kg (78.5 lb)Fully configured: 145.8 kg (321.5 lb)

Operating environmentLenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 22

Page 23: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

Operating environmentThe DB400D and DB800D 32Gb FC SAN Directors are supported in the following environment:

Air temperature:Operating: 0°C to 40°C (32°F to 104°F)Non-operating: -25°C to +70°C (-13°F to 158°F)

Maximum altitude:Operating: 3,000 m (9,842 ft)Non-operating: 12,000 m (39,370 ft)

Humidity:Operating: 5% to 93% non-condensing with 10% per hour maximum rate of changeNon-operating: 10% to 93% non-condensing

Electrical power:Voltage range: 100 V AC - 240 V AC (nominal)Frequency: 50 Hz / 60 Hz (nominal)Power consumption:

DB400D:Idle: 840 wattsTypical: 1407 wattsMaximum: 2438 watts

DB800D:Idle: 1515 wattsTypical: 2647 wattsMaximum: 4339 watts

Heat dissipation:DB400D:

Idle: 2867 BTU per hourTypical: 4802 BTU per hourMaximum: 8322 per hour

DB800D:Idle: 5171 BTU per hourTypical: 9034 BTU per hourMaximum: 14810 per hour

Acoustical noise emission:DB400D: 64.2 dBDB800D: 68.2 dB

Hardware warrantyThe DB400D and DB800D 32Gb FC SAN Directors have a one-year customer-replaceable unit (CRU)limited warranty with standard call center support during normal business hours and 9x5 Next Business DayParts Delivered. Also available are Lenovo Services warranty maintenance upgrades and post-warrantymaintenance agreements, with a well-defined scope of services, including service hours, response time,term of service, and service agreement terms and conditions.Lenovo warranty service upgrade offerings are country-specific. Not all warranty service upgrades areavailable in every country. For more information about Lenovo warranty service upgrade offerings that areavailable in your country, refer to the Data Center Advisor and Configurator Tool (DCACT; formerly knownas LESC) website: http://lesc.lenovo.com

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 23

Page 24: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

The following table explains warranty service definitions.

Table 14. Warranty service definitionsTerm DescriptionParts Delivered If a problem with your product cannot be resolved via telephone and a CRU part is required,

Lenovo will send a replacement CRU to arrive at your location. If a problem with your productcannot be resolved via telephone and a FRU part is required, a Service Technician will bedispatched to arrive at your location.

TechnicianInstalled Parts

If a problem with your product cannot be resolved via telephone, a Service Technician will bedispatched to arrive at your location.

Hours ofcoverage

9x5: 9 hours per day, 5 days per week, during normal business hours, excluding localpublic and national holidays24x7: 24 hours per day, 7 days per week, 365 days per year.

Response timetarget

24 hours or Next Business Day: The time period from when the telephone based troubleshooting iscompleted and logged, to the delivery of the CRU or arrival of a Service Technician and part at theCustomer’s location for repair.

The following Lenovo warranty service upgrades are available:Warranty and maintenance service upgrades:

One, three, four, or five years of 9x5 or 24x7 service coverageParts delivered or technician installed parts from next business day to 24 hoursWarranty extension of up to 5 yearsPost warranty extensions for 1 and 2 years

Remote Technical Support Services (RTS) - 1 or 3 yearsRTS provides comprehensive technical call center support. RTS can reduce problem resolution time,which decreases the cost to address technical problems and increases uptime.Hardware Installation ServicesLenovo experts can seamlessly manage the physical installation of your server, storage, or networkinghardware. Working at a time convenient for you (business hours or off shift), the technician will unpackand inspect the systems on your site, install options, mount in a rack cabinet, connect to power andnetwork, check and update firmware to the latest levels, verify operation, and dispose of thepackaging, allowing your team to focus on other priorities.

Regulatory complianceThe DB400D and DB800D 32Gb FC SAN Directors conform to the following regulations:

Electromagnetic compatibilityFCC Part 15, Subpart B (Class A)EN 55022 (CE mark) (Class A)EN 55024 (CE mark)ICES-003 (Canada) (Class A)AS/NZ 55022 (Australia) (Class A)VCCI (Japan) (Class A)EN 61000-3-2EN 61000-3-3EN 61000-6-1

SafetyUL/CSA 60950EN 60950IEC 60950

Environmental: EU RoHS

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 24

Page 25: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

Fibre Channel SAN switchesThe following table lists the FC SAN switches that are offered by Lenovo that can be used in Lenovo FCSAN solutions.

Table 15. FC SAN switches

DescriptionPartnumber

Rack-mount switches - 8 Gb FCLenovo B300, 8 ports activated w/ 8Gb SWL SFPs, 1 PS, Rail Kit 3873AR3Lenovo B6505, 12 ports activated w/ 8Gb SWL SFPs, 1 PS, Rail Kit 3873AR4Lenovo B6510, 24 ports activated w/ 8Gb SWL SFPs, 2 PS, Rail Kit 3873BR2Rack-mount switches - Gen 5 16 Gb FCLenovo B6505, 12 ports activated w/ 16Gb SWL SFPs, 1 PS, Rail Kit 3873AR5Lenovo B6510, 24 ports activated w/ 16Gb SWL SFPs, 2 PS, Rail Kit 3873BR3Rack-mount switches - Gen 6 16 Gb FCLenovo ThinkSystem DB610S, 8 ports activated, 8x 16Gb SWL SFPs, 1 PS, Rail Kit 6559D2YLenovo ThinkSystem DB610S, 24 ports activated, 24x 16Gb SWL SFPs, 1 PS, Rail Kit, Enterprise SW 6559D1YRack-mount switches - Gen 6 32 Gb FCLenovo ThinkSystem DB610S, 8 ports activated, 1 PS, Rail Kit 6559D3YLenovo ThinkSystem DB620S, 24 ports activated, 24x 32Gb SWL SFPs, 2 PS, Rail Kit 6415G11Lenovo ThinkSystem DB620S, 48 ports activated, 48x 32Gb SWL SFPs, 2 PS, Rail Kit, Enterprise SW 6415G2A

For more information, see the list of Product Guides in the Rack-mount SAN switches category:http://lenovopress.com/storage/switches/rack

External storage systemsThe following table lists the external storage systems that are offered by Lenovo that can be used in LenovoFC SAN solutions.

Table 16. External storage systems

DescriptionPartnumber

Lenovo ThinkSystem DS Series StorageLenovo ThinkSystem DS2200 LFF FC/iSCSI Dual Controller Unit (US English documentation) 4599A31*Lenovo ThinkSystem DS2200 LFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation) 4599A3C^Lenovo ThinkSystem DS2200 LFF FC/iSCSI Dual Controller Unit (Japanese documentation) 4599A3J**Lenovo ThinkSystem DS2200 SFF FC/iSCSI Dual Controller Unit (US English documentation) 4599A11*Lenovo ThinkSystem DS2200 SFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation) 4599A1C^Lenovo ThinkSystem DS2200 SFF FC/iSCSI Dual Controller Unit (Japanese documentation) 4599A1J**Lenovo ThinkSystem DS4200 LFF FC/iSCSI Dual Controller Unit (US English documentation) 4617A31*Lenovo ThinkSystem DS4200 LFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation) 4617A3C^Lenovo ThinkSystem DS4200 LFF FC/iSCSI Dual Controller Unit (Japanese documentation) 4617A3J**Lenovo ThinkSystem DS4200 SFF FC/iSCSI Dual Controller Unit (US English documentation) 4617A11*Lenovo ThinkSystem DS4200 SFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation) 4617A1C^

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 25

Page 26: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

Lenovo ThinkSystem DS4200 SFF FC/iSCSI Dual Controller Unit (Japanese documentation) 4617A1J**Lenovo ThinkSystem DS6200 SFF FC/iSCSI Dual Controller Unit (US English documentation) 4619A11*Lenovo ThinkSystem DS6200 SFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation) 4619A1C^Lenovo ThinkSystem DS6200 SFF FC/iSCSI Dual Controller Unit (Japanese documentation) 4619A1J**Lenovo Storage DX8200 Series (FC connectivity requires an optional FC HBA and a software license)Lenovo Storage DX8200D ServerSAN Entry, 8TB, 3yr SW S&S 5135D2x#Lenovo Storage DX8200D ServerSAN Entry, 8TB, 4yr SW S&S 5135N2x#Lenovo Storage DX8200D ServerSAN Entry, 8TB, 5yr SW S&S 51354Vx#Lenovo Storage DX8200D ServerSAN Mid, 16TB, 3yr SW S&S 5135F2x#Lenovo Storage DX8200D ServerSAN Mid, 16TB, 4yr SW S&S 5135P2x#Lenovo Storage DX8200D ServerSAN Mid, 16TB, 5yr SW S&S 51355Vx#Lenovo Storage DX8200D ServerSAN High, 32TB, 3yr SW S&S 5135G2x#Lenovo Storage DX8200D ServerSAN High, 32TB, 4yr SW S&S 5135Q2x#Lenovo Storage DX8200D ServerSAN High, 32TB, 5yr SW S&S 51356Vx#Lenovo Storage DX8200D Storage Virtualization Entry, 4TB, 3yr SW S&S 5135A2x#Lenovo Storage DX8200D Storage Virtualization Entry, 4TB, 4yr SW S&S 5135J2x#Lenovo Storage DX8200D Storage Virtualization Entry, 4TB, 5yr SW S&S 51351Vx#Lenovo Storage DX8200D Storage Virtualization Mid, 16TB, 3yr SW S&S 5135B2x#Lenovo Storage DX8200D Storage Virtualization Mid, 16TB, 5yr SW S&S 51352Vx#Lenovo Storage DX8200D Storage Virtualization Mid, 16TB, 4yr SW S&S 5135L2x#Lenovo Storage DX8200D Storage Virtualization High, 64TB, 3yr SW S&S 5135C2x#Lenovo Storage DX8200D Storage Virtualization High, 64TB, 4yr SW S&S 5135M2x#Lenovo Storage DX8200D Storage Virtualization High, 64TB, 5yr SW S&S 51353Vx#Lenovo Storage DX8200N with 1x N2226 HBA (Requires a supported external drive enclosure) 5128A1x#Lenovo Storage DX8200N with 2x N2226 HBAs (Requires a supported external drive enclosure) 5128A2x#Lenovo Storage S SeriesLenovo Storage S2200 LFF Chassis FC/iSCSI Single Controller, Rack Kit, 9x5NBD 64114B1Lenovo Storage S2200 LFF Chassis FC/iSCSI Dual Controller, Rack Kit, 9x5NBD 64114B2Lenovo Storage S2200 SFF Chassis FC/iSCSI Single Controller, Rack Kit, 9x5NBD 64114B3Lenovo Storage S2200 SFF Chassis FC/iSCSI Dual Controller, Rack Kit, 9x5NBD 64114B4Lenovo Storage S3200 LFF Chassis FC/iSCSI Single Controller, Rack Kit, 9x5NBD 64116B1Lenovo Storage S3200 LFF Chassis FC/iSCSI Dual Controller, Rack Kit, 9x5NBD 64116B2Lenovo Storage S3200 SFF Chassis FC/iSCSI Single Controller, Rack Kit, 9x5NBD 64116B3Lenovo Storage S3200 SFF Chassis FC/iSCSI Dual Controller, Rack Kit, 9x5NBD 64116B4Lenovo Storage V SeriesLenovo Storage V3700 V2 LFF Control Enclosure 6535C1DLenovo Storage V3700 V2 LFF Control Enclosure (Top Seller) 6535EC1Lenovo Storage V3700 V2 SFF Control Enclosure 6535C2DLenovo Storage V3700 V2 SFF Control Enclosure (Top Seller) 6535EC2Lenovo Storage V3700 V2 XP LFF Control Enclosure 6535C3DLenovo Storage V3700 V2 XP LFF Control Enclosure (Top Seller) 6535EC3

DescriptionPartnumber

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 26

Page 27: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

Lenovo Storage V3700 V2 XP SFF Control Enclosure 6535C4DLenovo Storage V3700 V2 XP SFF Control Enclosure (Top Seller) 6535EC4Lenovo Storage V5030 LFF Control Enclosure 3Yr S&S 6536C12Lenovo Storage V5030 LFF Control Enclosure 5Yr S&S 6536C32Lenovo Storage V5030 SFF Control Enclosure 3Yr S&S 6536C22Lenovo Storage V5030 SFF Control Enclosure 5Yr S&S 6536C42Lenovo Storage V5030F SFF Control Enclosure 3Yr S&S 6536B1FLenovo Storage V5030F SFF Control Enclosure 5Yr S&S 6536B2FIBM Storwize for LenovoIBM Storwize V3500 3.5-inch Dual Control Storage Controller Unit 6096CU2^IBM Storwize V3500 2.5-inch Dual Control Storage Controller Unit 6096CU3^IBM Storwize V3700 3.5-inch Storage Controller Unit 6099L2CIBM Storwize V3700 2.5-inch Storage Controller Unit 6099S2CIBM Storwize V7000 2.5-inch Storage Controller Unit, w/3 Yr S&S (Model 524) 6195SC5†IBM Storwize V7000 2.5-inch Storage Controller Unit, w/3 Yr S&S (LA) (Model 524) 6195SCL‡IBM Storwize V7000 2.5-inch Storage Controller Unit, w/5 Yr S&S (Model 524) 61951F1†IBM Storwize V7000 2.5-inch Storage Controller Unit, w/5 Yr S&S (LA) (Model 524) 61951FL‡IBM Storwize V7000 SFF Control Enclosure, 3YR SWMA (Model HC1 [Gen2+]) 6195C32†IBM Storwize V7000 SFF Control Enclosure, 3YR SWMA, LA (Model HC1 [Gen2+]) 6195C3L‡IBM Storwize V7000 SFF Control Enclosure, 5YR SWMA (Model HC1 [Gen2+]) 6195C52†IBM Storwize V7000 SFF Control Enclosure, 5YR SWMA, LA (Model HC1 [Gen2+]) 6195C5L‡

DescriptionPartnumber

* Available worldwide (except China and Japan).^ Available only in China.** Available only in Japan.# x represents a geo-specific letter (for example: U = North America, G = EMEA). Ask a Lenovo representative for specifics.† Available worldwide except Latin America.‡ Available only in Latin America.

For more information, see the list of Product Guides in the following categories:Lenovo DS Series, S Series, and V Series storage:http://lenovopress.com/storage/san/lenovo?rt=product-guideIBM Storwize for Lenovo storage:http://lenovopress.com/storage/san/ibm?rt=product-guide

External backup unitsLenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 27

Page 28: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

External backup unitsThe following table lists the external backup options that are offered by Lenovo that can be used in LenovoFC SAN solutions.

Table 17. External backup optionsDescription Part numberExternal tape backup librariesIBM TS3100 Tape Library Model L2U 61732ULIBM TS3200 Tape Library Model L4U 61734ULFibre Channel backup drives for TS3100 and TS3200 Tape Libraries6173 LTO Ultrium 5 Fibre Channel Drive 00NA1076173 LTO Ultrium 5 Half High Fibre Drive Sled 00NA1136173 LTO Ultrium 6 Fibre Channel Drive 00NA1156173 LTO Ultrium 6 Half High Fibre Drive Sled 00NA1196173 LTO Ultrium 7 Fibre Channel Drive 00WF7656173 LTO Ultrium 7 Half High Fibre Drive Sled 00WF769

For more information, see the list of Product Guides in the Backup Units category:http://lenovopress.com/servers/options/backup

Rack cabinetsThe following table lists the rack cabinets that are offered by Lenovo that can be used in Lenovo FC SANsolutions.

Table 18. Rack cabinetsDescription Part number25U S2 Standard Rack (1000 mm deep; 2 sidewall compartments) 93072RX25U Static S2 Standard Rack (1000 mm deep; 2 sidewall compartments) 93072PX42U S2 Standard Rack (1000 mm deep; 6 sidewall compartments) 93074RX42U 1100mm Enterprise V2 Dynamic Rack (6 sidewall compartments) 93634PX42U 1100mm Enterprise V2 Dynamic Expansion Rack (6 sidewall compartments) 93634EX42U 1200mm Deep Dynamic Rack (6 sidewall compartments) 93604PX42U 1200mm Deep Static Rack (6 sidewall compartments) 93614PX42U Enterprise Rack (1105 mm deep; 4 sidewall compartments) 93084PX42U Enterprise Expansion Rack (1105 mm deep; 4 sidewall compartments) 93084EX

For more information, see the list of Product Guides in the Rack cabinets category:https://lenovopress.com/servers/options/racks

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 28

Page 29: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

Power distribution unitsThe following table lists the power distribution units (PDUs) that are offered by Lenovo that can be used inLenovo FC SAN solutions.

Table 19. Power distribution units

DescriptionPartnumber

0U Basic PDUs0U 36 C13/6 C19 24A/200-240V 1 Phase PDU with NEMA L6-30P line cord 00YJ7760U 36 C13/6 C19 32A/200-240V 1 Phase PDU with IEC60309 332P6 line cord 00YJ7770U 21 C13/12 C19 32A/200-240V/346-415V 3 Phase PDU with IEC60309 532P6 line cord 00YJ7780U 21 C13/12 C19 48A/200-240V 3 Phase PDU with IEC60309 460P9 line cord 00YJ779Switched and Monitored PDUs0U 20 C13/4 C19 Switched and Monitored 24A/200-240V/1Ph PDU w/ NEMA L6-30P line cord 00YJ7810U 20 C13/4 C19 Switched and Monitored 32A/200-240V/1Ph PDU w/ IEC60309 332P6 line cord 00YJ7800U 18 C13/6 C19 Switched / Monitored 32A/200-240V/346-415V/3Ph PDU w/ IEC60309 532P6 cord 00YJ7820U 12 C13/12 C19 Switched and Monitored 48A/200-240V/3Ph PDU w/ IEC60309 460P9 line cord 00YJ7831U 9 C19/3 C13 Switched and Monitored DPI PDU (without line cord) 46M40021U 9 C19/3 C13 Switched and Monitored 60A 3Ph PDU with IEC 309 3P+Gnd cord 46M4003Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets)Ultra Density Enterprise C19/C13 PDU Module (without line cord) 71762NXUltra Density Enterprise C19/C13 PDU 60A/208V/3ph with IEC 309 3P+Gnd line cord 71763NUC19 Enterprise PDUs (6x IEC 320 C19 outlets)DPI Single Phase C19 Enterprise PDU (without line cord) 39Y8948DPI 60A 3 Phase C19 Enterprise PDU with IEC 309 3P+G (208 V) fixed line cord 39Y8923Front-end PDUs (3x IEC 320 C19 outlets)DPI 30amp/125V Front-end PDU with NEMA L5-30P line cord 39Y8938DPI 30amp/250V Front-end PDU with NEMA L6-30P line cord 39Y8939DPI 32amp/250V Front-end PDU with IEC 309 2P+Gnd line cord 39Y8934DPI 60amp/250V Front-end PDU with IEC 309 2P+Gnd line cord 39Y8940DPI 63amp/250V Front-end PDU with IEC 309 2P+Gnd line cord 39Y8935Line cords for PDUs that ship without a line cordDPI 30a Line Cord (NEMA L6-30P) 40K9614DPI 32a Line Cord (IEC 309 P+N+G) 40K9612DPI 32a Line Cord (IEC 309 3P+N+G) 40K9611DPI 60a Cord (IEC 309 2P+G) 40K9615DPI 63a Cord (IEC 309 P+N+G) 40K9613DPI Australian/NZ 3112 Line Cord (32A) 40K9617DPI Korean 8305 Line Cord (30A) 40K9618

For more information, see the list of Product Guides in the PDU category:https://lenovopress.com/servers/options/pdu

Uninterruptible power supply unitsLenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 29

Page 30: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

Uninterruptible power supply unitsThe following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo that can beused in Lenovo FC SAN solutions.

Table 20. Uninterruptible power supply unitsDescription Part numberRT1.5kVA 2U Rack or Tower UPS (100-125VAC) 55941AXRT1.5kVA 2U Rack or Tower UPS (200-240VAC) 55941KXRT2.2kVA 2U Rack or Tower UPS (100-125VAC) 55942AXRT2.2kVA 2U Rack or Tower UPS (200-240VAC) 55942KXRT3kVA 2U Rack or Tower UPS (100-125VAC) 55943AXRT3kVA 2U Rack or Tower UPS (200-240VAC) 55943KXRT5kVA 3U Rack or Tower UPS (200-240VAC) 55945KXRT6kVA 3U Rack or Tower UPS (200-240VAC) 55946KXRT8kVA 6U Rack or Tower UPS (200-240VAC) 55948KXRT11kVA 6U Rack or Tower UPS (200-240VAC) 55949KXRT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) 55948PXRT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) 55949PX

For more information, see the list of Product Guides in the Uninterruptible Power Supply Units category:http://lenovopress.com/servers/options/ups

Lenovo Financial ServicesLenovo Financial Services reinforces Lenovo’s commitment to deliver pioneering products and services thatare recognized for their quality, excellence, and trustworthiness. Lenovo Financial Services offers financingsolutions and services that complement your technology solution anywhere in the world.We are dedicated to delivering a positive finance experience for customers like you who want to maximizeyour purchase power by obtaining the technology you need today, protect against technology obsolescence,and preserve your capital for other uses.We work with businesses, non-profit organizations, governments and educational institutions to finance theirentire technology solution. We focus on making it easy to do business with us. Our highly experienced teamof finance professionals operates in a work culture that emphasizes the importance of providing outstandingcustomer service. Our systems, processes and flexible policies support our goal of providing customers witha positive experience.We finance your entire solution. Unlike others, we allow you to bundle everything you need from hardwareand software to service contracts, installation costs, training fees, and sales tax. If you decide weeks ormonths later to add to your solution, we can consolidate everything into a single invoice.Our Premier Client services provide large accounts with special handling services to ensure these complextransactions are serviced properly. As a premier client, you have a dedicated finance specialist whomanages your account through its life, from first invoice through asset return or purchase. This specialistdevelops an in-depth understanding of your invoice and payment requirements. For you, this dedicationprovides a high-quality, easy, and positive financing experience.For your region specific offers please ask your Lenovo sales representative or your technology providerabout the use of Lenovo Financial Services. For more information, see the following Lenovo website:http://www.lenovofs.com

Related publications and linksLenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 30

Page 31: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

Related publications and linksFor more information, see the following resources:

Lenovo FC SAN Switches product pagehttp://shop.lenovo.com/us/en/systems/storage/san/fibre-channel-switchesLenovo ThinkSystem DB400D and DB800D 32 Gb FC Director product publications, available fromthe Brocade Document Library:http://www.brocade.com/en/support/document-library/dl-segment-products-os-detail-page.brocadex6director.product.html

Hardware Installation GuideFabric OS Access Gateway Administration GuideFabric OS Administration GuideFabric OS Extension Configuration GuideFabric OS Troubleshooting and Diagnostics GuideFabric OS Command ReferenceFabric OS Message ReferenceFabric OS MIB ReferenceWeb Tools Administration GuideFlow Vision Configuration GuideMonitoring and Alerting Policy Suite Configuration Guide

How to download firmware for Lenovo B and DB Series switches:http://go.brocade.com/x0L0000S2Ig0GwG00ZAGBB4

Related product familiesProduct families related to this document are the following:

Rack SAN Switches

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 31

Page 32: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

NoticesLenovo may not offer the products, services, or features discussed in this document in all countries. Consult yourlocal Lenovo representative for information on the products and services currently available in your area. Anyreference to a Lenovo product, program, or service is not intended to state or imply that only that Lenovo product,program, or service may be used. Any functionally equivalent product, program, or service that does not infringe anyLenovo intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verifythe operation of any other product, program, or service. Lenovo may have patents or pending patent applicationscovering subject matter described in this document. The furnishing of this document does not give you any license tothese patents. You can send license inquiries, in writing, to:

Lenovo (United States), Inc.1009 Think Place - Building OneMorrisville, NC 27560U.S.A.Attention: Lenovo Director of Licensing

LENOVO PROVIDES THIS PUBLICATION ”AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS ORIMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT,MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some jurisdictions do not allow disclaimer ofexpress or implied warranties in certain transactions, therefore, this statement may not apply to you.

This information could include technical inaccuracies or typographical errors. Changes are periodically made to theinformation herein; these changes will be incorporated in new editions of the publication. Lenovo may makeimprovements and/or changes in the product(s) and/or the program(s) described in this publication at any time withoutnotice.

The products described in this document are not intended for use in implantation or other life support applicationswhere malfunction may result in injury or death to persons. The information contained in this document does notaffect or change Lenovo product specifications or warranties. Nothing in this document shall operate as an express orimplied license or indemnity under the intellectual property rights of Lenovo or third parties. All information containedin this document was obtained in specific environments and is presented as an illustration. The result obtained inother operating environments may vary. Lenovo may use or distribute any of the information you supply in any way itbelieves appropriate without incurring any obligation to you.

Any references in this publication to non-Lenovo Web sites are provided for convenience only and do not in anymanner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materialsfor this Lenovo product, and use of those Web sites is at your own risk. Any performance data contained herein wasdetermined in a controlled environment. Therefore, the result obtained in other operating environments may varysignificantly. Some measurements may have been made on development-level systems and there is no guaranteethat these measurements will be the same on generally available systems. Furthermore, some measurements mayhave been estimated through extrapolation. Actual results may vary. Users of this document should verify theapplicable data for their specific environment.

© Copyright Lenovo 2017. All rights reserved.

This document, LP0581, was created or updated on June 20, 2017.Send us your comments in one of the following ways:

Use the online Contact us review form found at:https://lenovopress.com/LP0581Send your comments in an e-mail to:[email protected]

This document is available online at https://lenovopress.com/LP0581.

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 32

Page 33: Lenovo ThinkSystem DB400D and DB800D 32Gb FC …isby.s3.amazonaws.com/lenovopartnernetwork.com/upload/4/docs/... · Lenovo ThinkSystem DB400D and DB800D ... Fabric Vision technology,

TrademarksLenovo, the Lenovo logo, and For Those Who Do are trademarks or registered trademarks of Lenovo in theUnited States, other countries, or both. A current list of Lenovo trademarks is available on the Web athttp://www.lenovo.com/legal/copytrade.html.The following terms are trademarks of Lenovo in the United States, other countries, or both:Lenovo®Lenovo Services™ThinkSystem™Other company, product, or service names may be trademarks or service marks of others.

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors 33