Lek2110 Training

download Lek2110 Training

of 30

Transcript of Lek2110 Training

  • 8/3/2019 Lek2110 Training

    1/30

    LEK-2110 Line Extender

    Trans Electric Co.Ltd

  • 8/3/2019 Lek2110 Training

    2/30

    Order Information

    LEK 2110 /37 42/54

    Line

    Extender

    K=KS

    2=2 IC

    1111=1 output

    37=Gain

    Band split

    10=1002MHz

  • 8/3/2019 Lek2110 Training

    3/30

    Product Feature (Housing)

    1.5GHz Platform,15A Power passing capacity.

    Die-cast housing with fin design and with

    painted coating provide good environmental

    protection and heat dissipating.RFI gasket with silicon rubber and mesh alloy,

    provide good RFI shielding.

    Water-proof gasket and con-cav mechanical

    design provide the good water-proof.Data log sticker for normal operation.

  • 8/3/2019 Lek2110 Training

    4/30

    Feature ( Housing)

    1.Input Port( Power/RF )

    2.Socket for amplifier module

    3.Pin fixation screws

    4.Data Log

    5.Pin length marker

    (37mm~44mm)6.DIMENSION(LxWxH)

    262190114 mm

    5

    1

    2 3

    4

  • 8/3/2019 Lek2110 Training

    5/30

    Feature (Housing)

    1.Screws for closing the Upper and Lower

    housing (spec 1/4)

    2.Screws for hinge of upper and lower

    housing

    3.Screws for cable messenger mechanism

    (distance 150mm,spec 1/4)4.Pedestral and cabinet mounting hole

    (distance 37.6mm,1/420 pitches)

    5.Sustain point for wall mount

    2

    34

    5

    1

  • 8/3/2019 Lek2110 Training

    6/30

    Feature (Amplifier Module)

    2 stages GaAs hybrids IC. Provide higher

    output level and better performance

    Plug-in diplexer, it is easy to upgrade thesystem band-split without change the amplifier

    Plug-in EQ,ATT,AGC, provide the stable

    performance for high frequency operation.

    All the test point with coupler type, stable andaccurate

    AGC module (option)

    Module can be 180 degree turn for convenient

    installation

    15A current passing,25A transient current

    GAS tube surge arrestor

  • 8/3/2019 Lek2110 Training

    7/30

    Feature (Forward Path)

    1.Forward input T.P.(Coupler,-20dB)

    2.Forward Input ATT(AT-*M)3.Forward EQ(EQ-1G-*)

    4.Inter-stage ATT(AT-*M)

    5.Inter-stage EQ(EQ-1G-18WC)

    6.AGC module(AGC-425)

    7.AGC ATT(AT-*M)

    8.Forward Output T.P.(Coupler,-20dB)

    3 4 6

    8

    5

    1

    2 7

  • 8/3/2019 Lek2110 Training

    8/30

    Product (Return /Powering Path)

    1.Return Input T.P.(Coupler,-20dB)

    2.Return Input ATT(AT-*M)

    3.Return Output ATT(AT-*M)

    4.Return Output EQ(REQ-*M)

    5.Return Output T.P.(Coupler,-20dB)

    6.PORT1 Powering Fuse(25A)

    7.PORT2 Powering Fuse(25A)

    8.T.P. DC 24V

    9.Working Indication (Green LED)

    5

    4 3 2

    1

    6 9 78

  • 8/3/2019 Lek2110 Training

    9/30

    SpecificationItem Forward Return unit

    Frequency Range 42/54Bandsplit 54~1002MHz 5~42MHz MHz

    Amplifier Technology Power Doubling Push-Pull

    Flatness 0.75 0.75 dB

    Gain 37 19 dB

    Internal Slope 14.51.0 N/A dB

    Return Loss(54~870/870~1002MHz) 16/14 16 dB

    T.P. Input/output -201.0 dB

    Input Level 15 21 dBmV

    Output Level(54/550/750/870/1002) 37.5/45/48/50/52 40 dBmV

    Channel Loading (NTSC) 79 112 6 CH

    Noise Figure 12 8 dB

    CSO

    AGC/ without AGC

    -71/-73 -64/-66 -81 dBCTBAGC/Without AGC -68/-70 -58/-61 -80 dB

    X-MODAGC/without AGC -68/-70 -59/-61 -70 dB

    HUM(15A) -65 -60 dB

  • 8/3/2019 Lek2110 Training

    10/30

    Functional Diagram

  • 8/3/2019 Lek2110 Training

    11/30

    Open and close the housing

    1.Open the housing: Loosing the screws

    sequentially as

    2.Close the hosing:

    a.Use bare hand to close the screws

    sequentially.

    b.Then use screw driver to close tightly

    3.Screw spec:5/16

    3 1 5

    6 2 4

  • 8/3/2019 Lek2110 Training

    12/30

    LEK-2110 torque requirement

  • 8/3/2019 Lek2110 Training

    13/30

    Forward installation and operation (Normal)

    1.Make sure the powering direction, plug and unplug

    the powering fuse.

    2.Check the +24VDC3. Choose the suitable input ATT

    actual level - 15dBmV(in the whole band) =ATT value

    (20 15 = 5 ie.AT-5M)

    4.Choose suitable EQ

    6.Choose the inter-stage ATT(default with ATT-2

    Output level designed Level = ATT value

    51 50 = 1 (must add 2dB, the value is AT-3M)

    7. Output Level

    37.5/45/48/50/52dBmV(54/550/750/870/1002MHz)

    8765432AT-*M

    46474849505152Outputlevel

    @1002MHz

    5.Set the Auto Level to medium

  • 8/3/2019 Lek2110 Training

    14/30

    1.Make the suitable length(37mm~44mm)

    Make the cable connector

    2.Loosing the screw on pin seizure

    mechanism (counter-clock direction)

    3.Tight the connector into housing

    Before After4.Tightening the screw on pin seizure

    mechanism (clock direction)

  • 8/3/2019 Lek2110 Training

    15/30

    Forward installation and Operation (recommended)

    1.Select proper Input ATT

    Input level - 15dBmV(lowest @whole band ) = ATT value

    (20 15 = 5, AT-5M is the proper one)

    2.Select proper input EQ

    If the input is reverse tilt (Lower channel is higher than

    higher, choose EQ(EQ-1G-*)

    if the input is tilt( higher channel is higher than lower

    channel , choose cable simulator(EQ-1G-C*)

    4.Select inter-stage ATT: Factory default is AT-2M

    Actual output level designed level = ATT value

    49(750MHz)48(750MHz) = 1 dB but you need to add 2 db so

    the AT should be AT-3M

    The output level37.5/48/50(54/750/870MHz)

    3.Set the Auto Level knob to proper position

    Factory default is set to lowest (min gain)

    please turn it at center position

  • 8/3/2019 Lek2110 Training

    16/30

    Input Level of LEK-2110

    Inputlevel(dBmv)

    Inputlevel

    (dBmv)

    Freq

    (MHz)54 550 750870

    Negativeslope

    15dBmv

    1002MHz

    1002

    Freq(MHz)

    54 550 750

    870

    Positiveslope

    15dBmv

    54MHz

    1002

    Inputlevel

    (dBmv)

    Freq

    (MHz)54 550 750870

    15dBmv

    Any point

    1002

  • 8/3/2019 Lek2110 Training

    17/30

    Installation and Operation of AGC

    1.AGC module installation(1)unplug the AC powering fuse

    (2)Take out the jumper wire form AGC location

    (3)Push the AGC module into AGC position

    and install the AGC-ATT (AT-7M)

    (4)screw the ground pad of AGC module on

    face plate

    (5)plug the AC Powering Fuse

    2.Choose inter-stage ATTif you use AGC module, you need to change the

    inter-stage ATT from 2dB to 0dB

    4.Change AGC ATT to the proper output level (2LEDs of AGC module will be dimmed)

    3.AUTO LEVEL knob must set to central

  • 8/3/2019 Lek2110 Training

    18/30

    Procedure for AGC Alignment

    Step 5

    Step 4

    Step 3

    Step 2

    Step 1

    Change AGC-ATT to

    lower value

    Check the LED if green is

    on then output level is toohigh

    Change AGC-ATT tohigher value

    Check the LED if red is onthen output level is too low

    Pre-installed ATT is AT-

    4M

    Choose proper AGC-ATTValue

    Turn the knob into center

    position

    Auto Level adjust knob

    Change to AT-0Inter-stage ATT

  • 8/3/2019 Lek2110 Training

    19/30

    Flow chart for AGC alignment

    Install AGC module

    Plug Poweringfuse

    AGC Setup Finish

    2 LEDsdimmed

    Change lower value

    ATT

    AGC indication

    AGC-ATT value AT-4M

    Auto Level knob at center

    Decrease inter-stageATT value by 2dB

    Change higher ATT

    Higher Output (Green LED) Lower Output (Red LED)

    Desired output

  • 8/3/2019 Lek2110 Training

    20/30

    Operation AGC

    +2dBmV

    -2dBmV

    10dBmV5dBmV

    AT-7M

    AT-8M

    +2dBmV

    5dBmV

    -2dBmV

    AT-6M

    +2dBmV

    5dBmV

    -2dBmV

    +2dBmV

    -2dBmV

    11dBmV5dBmV

    AT-7M

    +2dBmV

    -2dBmV

    9dBmV5dBmV

    AT-7M

    Input level + AGC Gain-AGC AT

    10+2-7=5

    Input Level + AGC Gain AGC A

    11+1-7=5(AGC -1dB Gain)11+2-8=5

    Input Level + AGC Gain AGC A

    9+3-7=5(AGC +1dB Gain)

    9+2-6=5

  • 8/3/2019 Lek2110 Training

    21/30

    Special notice for AGC module

    Specification of AGC

    Notice for AGC module operation

    (1) The pilot channel for AGC module are CH57 and CH58

    (2) Before install the AGC module, you need to remove the jumper

    of AGC location(If you do not want the AGC module and jumper is removed,

    please plug the jumper into original position.

    dBmV2dBLevel adjustment range

    CH57,58Pilot channelmA80Current consumption

    V240.5Voltage

    -40~+60Operating Temperature

    UnitspecItem

  • 8/3/2019 Lek2110 Training

    22/30

    Return Path Alignment-- Unity Gain

    1.Choose output ATT

    Value=(output levelloss of passive

    previous)-input level of return IC

    2.Choose Return EQ

    3.Using Equipment for alignment,

    Injection at Return injection

    point( Forward output T.P.)

    injection level=input level of return IC

    +return path loss+Coupler loss of T.P.+Return ATT

    I.E.: IC input level 10dBmV,injection

    level=10+2+20+5 = 37 dBmV.

    Return injectionForward output signalorward input signal

  • 8/3/2019 Lek2110 Training

    23/30

    The loss at different location of amplifier

    -2dB-2dB

    -2.5dB

    20dB

  • 8/3/2019 Lek2110 Training

    24/30

    Return Alignment

    -25dB +15 dB +0 dB

    source (TX) 37dBmV

    Source (TX) 34dBmV

    PAD= X

    Source (TX) 37dBmV

    LE

    PAD=4dBPAD=0dB

    PAD= X dB

    2

    1

    2

    1

    +3 dB

  • 8/3/2019 Lek2110 Training

    25/30

    Configuration of accessories

    AT-*M1AT-2Minter-stage ATT

    AT-*M1BlankAGC-ATT

    3JumperReturn Input ATT

    Optional

    REQ-*M1JumperReturn Output EQ

    AT-*M1JumperReturn Output ATT

    EQ-1G-*1JumperForward Input EQ

    AT-*M1blankForward input ATT

    Must install

    1EQ-1G-18Output EQ

    AGC-4251JumperAGC module

    Pre-installed

    Model noQtyModel no (pre-installed)

    Item

  • 8/3/2019 Lek2110 Training

    26/30

    Plug-in Accessories

    ATT: AT-0M~AT-19M,Step1dB

    Forward EQ: EQ-0dB

    EQ-1G-2~EQ-1G-20,Step 1dB

    EQ-1G-C1~EQ-1G-C12,Step1dB

    Return EQ: REQ-01M~REQ-09M,Step 1dB

  • 8/3/2019 Lek2110 Training

    27/30

    Forward EQ

    1.52.94.87.17.99.512.418.720.0EQ-1G-20M

    1.42.84.57.07.89.412.117.719.0EQ-1G-19M

    1.22.44.56.37.08.711.416.818EQ-1G-18M

    1.83.14.56.47.08.410.91617EQ-1G-17M

    1.32.53.95.86.58.010.31516EQ-1G-16M1.32.53.95.66.27.59.71415EQ-1G-15M

    1.52.63.95.66.27.49.413.214EQ-1G-14M

    1.42.43.65.15.76.88.51213EQ-1G-13M

    1.52.23.24.65.16.17.811.312EQ-1G-12M

    1.72.33.24.55.05.97.410.311EQ-1G-11M

    1.52.12.94.14.65.36.59.310EQ-1G-10M

    1.52.12.83.84.256.18.59EQ-1G-09M

    1.31.72.23.13.44.25.47.68EQ-1G-08M

    1.21.72.33.23.54.04.96.77EQ-1G-07M

    1.21.51.92.72.93.54.25.76EQ-1G-06M

    1.11.51.92.52.73.13.74.85EQ-1G-05M

    1.21.41.51.92.12.53.03.84EQ-1G-04M

    111.21.51.61.92.22.53EQ-1G-03M

    0.80.91.11.21.31.31.41.82EQ-1G-02M

    0.330.270.250.20.180.140.100EQ-1G-0M

    10028707506005504503008554

    Frequency (MHz)Model No

  • 8/3/2019 Lek2110 Training

    28/30

    Cable Simulator EQ

    12.010.910.339.248.547.545.722.672.06EQ-1G-C12M

    11.010.09.628.828.087.175.442.592.02EQ-1G-C11M

    10.09.308.818.037.446.554.932.281.75EQ-1G-C10M

    9.08.397.827.006.545.814.371.921.43EQ-1G-C9M

    8.07.376.846.325.835.233.981.831.40EQ-1G-C8M

    7.06.596.015.505.004.453.351.501.13EQ-1G-C7M

    6.05.645.244.804.413.892.891.190.85EQ-1G-C6M

    5.04.384.003.643.342.972.170.870.61EQ-1G-C5M

    4.03.463.162.892.672.401.770.660.45EQ-1G-C4M

    3.02.402.161.971.821.631.150.290.13EQ-1G-C3M

    2.01.521.281.100.930.780.510.110.03EQ-1G-C2M

    10028707506005504503008554

    Frequency (MHz)Model No

  • 8/3/2019 Lek2110 Training

    29/30

    Return EQ

    0.440.680.862.055.206.40REQ-09M

    0.270.700.871.934.835.93REQ-08M

    0.170.690.821.724.235.34REQ-07M

    0.070.550.651.363.654.60REQ-06M

    0.130.710.811.423.284.02REQ-05M

    0.200.720.801.312.843.43REQ-04M

    0.080.480.550.992.062.50REQ-03M

    0.050.430.480.781.461.80REQ-02M

    0.270.640.670.871.191.37REQ-01M

    65MHz42MHz40MHz30MHz10MHz5MHzModel no

  • 8/3/2019 Lek2110 Training

    30/30

    Level at different frequency

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    1112

    13

    14

    15

    16

    17

    54 100 200 300 400 500 600 700 800 900 100(MHz)

    Slope 17.5dB Slope 14.5dB Slope 12.5dB