LEITH AUTO CENTER BUILDING EXPANSION SR-16-2017 AUTO CENTER BUILDING EXPANSION ¯ SR-16-2017! ......
-
Upload
vuongnguyet -
Category
Documents
-
view
222 -
download
3
Transcript of LEITH AUTO CENTER BUILDING EXPANSION SR-16-2017 AUTO CENTER BUILDING EXPANSION ¯ SR-16-2017! ......
CAPITAL BLVD
OAK FOREST DR
HICKORY RD
SUMNER BLVD
OLD WAKE FOREST RDDO
GWOO
D DR
TRUST DR
DEPA
RTUR
E DR
FORE
ST D
R
BARROW DR
TANG
LEWO
OD D
R
MELV
ILLE D
R
MORGANTOWN STCLARKSBURG PL
PARKERSBURG ST
CAPITAL BLVD
SUMNER BLVD
Zoning:CAC:
Drainage Basin:Acreage:
Sq. Ft.:
IX-3, CX-3-PL,IX-4-PL-CUNorthMarsh Creek14.0344,107
0 600 1,200300 Feet
Planner:Phone:
Applicant:Phone:
Daniel Stegall(919) 996-2712Bill Daniel(919) 467-9708
¯LEITH AUTO CENTER BUILDING EXPANSIONSR-16-2017
!
CAPITAL BOULEVARD (NORTHBOUND LANE)
T
A
N
G
L
E
W
O
O
D
CAPITAL BOULEVARD (SOUTHBOUND LANE)
ROBERT T. HEDRICK
DB 11520, PG. 1334
ZONING: IX-4-PL-CU
USE: SINGLE FAMILY
N/F
MLC AUTOMOTIVE, LLC
DB 11798, PG. 1210
ZONING: CX-3-PL
USE: VACANT
N/F
KENNETH D. KENNEDY
DB 02961, PG. 0707
ZONING: IND-1
USE: FLEX WAREHOUSE
N/F
CLARENCE & LIBBY JONES
DB 1575, PG. 696
ZONING: R-6
USE: SINGLE FAMILY
N/F
CLAUDE E. PERRY
DB 1572, PG. 233
ZONING: R-6
USE: SINGLE FAMILY
N/F
HEDRICK, ROBERT T.
DB 11520, PG. 1340
ZONING: IX-3
USE: VACANT
N/F
D
R
IV
E
GOLD MOON, LLC
DB 8980, PG. 1819
ZONING: IND-1
USE: AUTOMOBILE DEALERSHIP
N/F
ARGONAUT HOLDINGS INC C/O
DB 9556, PG. 851
ZONING: CUD BUS
USE: SALES & SERVICE
N/F
WORLDWIDE REAL ESTATE
EDWARD GREEN
DB 11083, PG. 100
ZONING: R-6
USE: VACANT
N/F
EDWARD GREEN
DB 11083, PG. 100
ZONING: R-6
USE: SINGLE FAMILY
N/F
JIMMY LYNCH
DB 11190, PG. 0035
ZONING: R-6
USE: SINGLE FAMILY
N/F
NC ELECTRIC MEMBERSHIP CORP.
DB 03164, PG. 898
ZONING: TD
USE: OFFICE
N/F
NC ELECTRIC MEMBERSHIP CORP.
DB 03480, PG. 411
ZONING: TD
USE: FLEX WAREHOUSE
N/F
HUDSON HAINES, JR.
DB 03334, PG. 457
ZONING: TD
USE: COMMERCIAL
N/F
SSC ACQUISITIONS INC
DB 06265, PG. 200
ZONING: TD
USE: MINI-WAREHOUSE
N/F
ONEAL NORTH RALEIGH
DB 03613, PG. 0396
ZONING: TD
USE: OFFICE
N/F
ONEAL NORTH RALEIGH
DB 03613, PG. 0396
ZONING: TD
USE: OFFICE
N/F
O
A
K
F
O
R
E
S
T
D
R
I
V
E
DR
IV
E
OA
K F
OR
ES
T
5850 OAK FOREST DRIVE
6700 WAKE FOREST ROAD
5909 CAPITAL BLVD.
5849 CAPITAL BLVD.
5839 CAPITAL BLVD.
3400 SUMNER BLVD.
5660 CAPITAL BLVD.
5640 CAPITAL BLVD.5602 CAPITAL BLVD.
5600 CAPITAL BLVD.
5501 OAK FOREST DRIVE
5501 CAPITAL BLVD.
5617 OAK FOREST DRIVE
5621 OAK FOREST DRIVE
5705 OAK FOREST DRIVE
5700 OAK FOREST DRIVE
5603 CAPITAL BOULEVARD
25
.0
'
PIN #: 1726288599
PIN #: 1726392217
PIN #: 1726291032
PIN #: 1727202654
PIN #: 1727302309
PIN #: 1727302289
PIN #: 1727304088
PIN #: 1726491980
PIN #: 1726492472
PIN #: 1726492200PIN #: 1726482908
PIN #: 1726481798
PIN #: 1726483612
PIN #: 1726386421
PIN #: 1726383471
PIN #: 1726382355
PIN #: 1726289239
EXISTING CAPITAL BLVD. (US 1)
(200' PUBLIC R/W)
(
E
X
.
6
0
'
P
U
B
L
I
C
R
/
W
)
MLC AUTOMOTIVE, LLC
BOM 2016 PG 214&215
ZONING: CX-3-PL
USE: AUTOMOBILE DEALERSHIP
5603 CAPITAL BLVD.
(LOT 2)
PARCEL BOUNDARY
20
0.0
0'
47
.0
'
45
.7
'
10
0.0
0'
64.9'
TBM
N = 769,821.4792
E = 2,123,722.3579
ELEV. 307.39 (NAVD 88)
20
0.0
0'
46
.3
'
65.7'
(LOT 1)
PARCEL BOUNDARY
F
O
R
E
S
T
D
R
IV
E
D
O
G
W
O
O
D
D
R
I
V
E
N/F
ROBERT T. HEDRICK
DB 14765, PG. 1931
ZONING: IX-4-PL-CU
USE: VACANT
0 OAK FOREST DRIVE
PIN #: 1726286588
1.93 ACRES
MLC AUTOMOTIVE, LLC
BOM 2016 PG 1089
ZONING: CX-3-PL
MLC AUTOMOTIVE, LLC
BOM 2016 PG 1089
ZONING: CX-3-PL
USE: AUTOMOBILE DEALERSHIP
HIGH INTENSITY
HIGH INTENSITY
HIGH INTENSITY
HIGH INTENSITY
O
A
K
F
O
R
E
S
T
D
R
I
V
E
MLC AUTOMOTIVE, LLC
DB 11798, PG. 1210
ZONING: CX-3-PL
USE: VACANT
N/F
5605 CAPITAL BOULEVARD
PIN #: 1726284874
MLC AUTOMOTIVE, LLC
DB 11798, PG. 1210
ZONING: IX-3
USE: VACANT
N/F
5603 CAPITAL BOULEVARD
PIN #: 1726392217
MLC AUTOMOTIVE, LLC
DB 11798, PG. 1210
ZONING: IX-4-PL-CU
USE: VACANT
N/F
5603 CAPITAL BOULEVARD
PIN #: 1726392217
HIGH INTENSITY
HIGH INTENSITY
N/F
SCHMALZ PROPERTY USA, LLC
DB 15728, PG. 2098
ZONING: IX-3
USE: WAREHOUSE
5850 OAK FOREST DRIVE
PIN #: 1726292078
N/F
SCHMALZ PROPERTY USA, LLC
DB 15728, PG. 2098
ZONING: IX-3
USE: WAREHOUSE
5850 OAK FOREST DRIVE
PIN #: 1726292078
MLC Automotive, LLC
5601 Capital Blvd.
Raleigh, NC 27616
(919) 876-5432
1" = 100'
OWNER:
Cover
GRADING, STORM, & EROSION CONTROL PLAN
PUBLIC IMPROVEMENT QUANTITIES
PUBLIC SEWER 0 LF
0 LFPUBLIC WATER
PUBLIC STREET 400 LF
PUBLIC SIDEWALK 362 LF
# OF LOTS 1 (Existing)
LOT # 2
EXISTING CONDITIONS PLAN
DETAILS
DESCRIPTIONSHEET NO.COVERCS-1
SITE PLAN
BOM 2016 PAGE 214CS-2
CS-3CS-4
CS-1
CS-5
CS-7
CS-6
LANDSCAPE PLAN
VICINITY MAP
1" = 1000'
O
L
D
W
A
K
E
F
O
R
E
S
T
R
O
A
D
C
AP
IT
AL B
LV
D
.
O
A
K
S
U
M
N
E
R
B
L
V
D
.
S
U
M
N
E
R
B
L
V
D
.
F
O
R
E
S
T
D
R
.
SITE
D
E
P
A
R
T
U
R
E
D
R
.
February 3, 2017
C-0329
Preliminary Plan
CS-10
BOM 2016 PAGE 215CS-2a
BLOCK PERIMETER CALCULATION
Solid Waste Compliance Statement:These plans have been reviewed by the design engineerand developer and are in compliance with therequirements set forth in the Solid Waste Design Manual.
PROJECT NOTE:THIS PLAN PROPOSES A BUILDINGADDITION W/ SUPPORTINGINFRASTRUCTURE AND LIMITEDOUTDOOR STORAGE FOR AN EXISTINGAUTOMOBILE DEALERSHIP. NO CHANGEIN SITE USE PROPOSED ON THIS PLAN.
CS-8 LANDSCAPE DETAILSCS-9
SOLID WASTE SERVICES PLAN
Lot 2 Expansion
Impervious Area Data
Existing Conditions:
VSA 184,694sf (4.24ac)
Building 40,753sf (0.94ac)
Existing Total: 225,447sf (5.18ac)
Proposed Conditions:
VSA 334,976sf (7.69ac)
Building 50,685sf (1.17ac)
Proposed Total: 385,661sf (8.86ac)
This plan proposes an increase to impervious
area by 160,214 sf (3.68 ac).
EXISTING BLOCK PERIMETER = 11,120 lf
MAX BLOCK PERIMETER = 4,000 lf
ZONING: IX-4-PL-CU, IX-3, & CX-3-PL
NOTE:
A DESIGN ADJUSTMENT WILL BE
SUBMITTED
TREE CONSERVATION AREA PLAN
LOT 2
DETAILSCS-11
Leith Auto Center Lot 2
Bldg Addition & Parking
Expansion
5603 Capital Boulevard
5800 Oak Forest Drive
SITE PLAN
DETAILSCS-12CS-13
ISOLUX PLAN
LIMITED OUTDOOR
STORAGE
BLDG.
ADDITION
W/ PARKING
ALL CONSTRUCTION SHALL BE IN STRICT
ACCORDANCE WITH CURRENT CITY OF RALEIGH
AND/OR NCDOT STANDARDS AND SPECIFICATIONS.
1 of 1
NPDES SECIFIC PLANCS-6.1
TR
AN
SA
CT
IO
N #
50
31
71
SR-16-17
SCM DETAILSCS-14
BUILDING FLOOR PLANA100BUILDING ELEVATIONSA101
5.18 ac
8.86 ac
9,932 sf
50,685 sf
320
330
ROBERT T. HEDRICK
DB 11520, PG. 1334
ZONING: IX-4-PL-CU
USE: SINGLE FAMILY
N/F
HEDRICK, ROBERT T.
DB 11520, PG. 1340
ZONING: CUD IND-1 & IND-1
USE: VACANT
N/F
KENNETH D. KENNEDY
DB 02961, PG. 0707
ZONING: IND-1
USE: FLEX WAREHOUSE
N/F
HEDRICK, ROBERT T.
DB 11520, PG. 1340
ZONING: CUD IND-1 & IND-1
USE: VACANT
N/F
GOLD MOON, LLC
DB 8980, PG. 1819
ZONING: IND-1
USE: AUTOMOBILE DEALERSHIP
N/F
5606 OAK FOREST DRIVE.
ZONING: CX-3-PL
BOM 2016 PG 214&215
MLC AUTOMOTIVE, LLC
332
334
336
328
326
324
322
318
25
.0
'
CLAUDE E. PERRY
DB 1572, PG. 233
ZONING: R-6
USE: SINGLE FAMILY
N/F
5849 CAPITAL BLVD.
PROPERTY LINE &
PROJECT BOUNDARY
330
320
PROPERTY LINE &
PROJECT BOUNDARY
PERMANENTLY
PRESERVED
UNDISTURBED
OPEN SPACE
SECONDARY TREE
CONSERVATION AREA
65' PERIMETER YARD
(0.30 Ac.)
PERMIT # 10644
OPEN SPACE
UNDISTURBED
PRESERVED
PERMANENTLY
ALTERNATE
COMPLIANCE
SECONDARY TREE
CONSERVATION AREA
32' PERIMETER YARD
(0.84 Ac.)
PERMIT # 10644
PERMANENTLY
PRESERVED
UNDISTURBED
OPEN SPACE
EXISTING
ALTERNATE
COMPLIANCE
SECONDARY TREE
CONSERVATION AREA
32' PERIMETER YARD
(0.44 Ac.)
PERMIT # 10645
BOM 2007 PG 2120
PROP. 6" TA
PPING
SLEEVE W
ITH VA
LVE
6" DIP
FIRELINE
FDC
CURB & PARKING
SHIFTED 2.15' SOUTH
2.15'
2.5'R
5'R5'RARGONAUT HOLDINGS INC C/O
DB 9556, PG. 851
ZONING: CUD BUS
USE: SALES & SERVICE
N/F
WORLDWIDE REAL ESTATE
5501 CAPITAL BLVD.
30.7'
EDWARD GREEN
DB 11083, PG. 100
ZONING: R-6
USE: SINGLE FAMILY
N/F
5621 OAK FOREST DRIVE
EDWARD GREEN
DB 11083, PG. 100
ZONING: R-6
USE: VACANT
N/F
5617 OAK FOREST DRIVE
ONEAL NORTH RALEIGH
DB 03613, PG. 0396
ZONING: TD
USE: OFFICE
N/F
5501 OAK FOREST DRIVE
20
3.4
'
5600 CAPITAL BLVD.
N/F
USE: OFFICE
ZONING: TD
DB 03613, PG. 0396
ONEAL NORTH RALEIGH
64.8'
46
.4
'
5602 CAPITAL BLVD.
N/F
USE: MINI-WAREHOUSE
ZONING: TD
DB 06265, PG. 200
SSC ACQUISITIONS INC
5640 CAPITAL BLVD.
N/F
USE: COMMERCIAL
ZONING: TD
DB 03334, PG. 457
HUDSON HAINES, JR.
23
.6
'
MLC AUTOMOTIVE, LLC
BOM 2016 PG 214&215
ZONING: IND-1
USE: AUTOMOBILE DEALERSHIP
5603 CAPITAL BLVD.
5601 CAPITAL BLVD.
USE: AUTOMOBILE DEALERSHIP
ZONING: CX-3-PL
BOM 2016 PG 214&215
MLC AUTOMOTIVE, LLC
NEW PROPERTY LINE TO BE ESTABLISHED VIA RECOMBINATION PLAT
EX. PROPERTY LINE TO BE REMOVED VIA RECOMBINATION PLAT
LOW INTENSITY
HIGH INTENSITY
HIGH INTENSITY
HIGH INTENSITY
SECONDARY TREE
CONSERVATION AREA
11" DBH PINE
FLO
OD
P
RO
NE
A
RE
A LIM
IT
S
(F
RO
M C
OR
IM
AP
S)
5
0
'
5
0
'
E
X
.
N
R
B
FLO
O
D
P
R
O
N
E A
R
EA
LIM
IT
S
(F
R
O
M
C
O
R
IM
AP
S)
E
X
. N
R
B
SECONDARY TREE
CONSERVATION AREA
11" DBH SWEET GUM
SECONDARY TREE
CONSERVATION AREA
13" DBH SWEET GUM
SECONDARY TREE
CONSERVATION AREA
12" DBH SWEET GUM
SECONDARY TREE
CONSERVATION AREA
10" DBH PINE
SECONDARY TREE
CONSERVATION AREA
13" DBH PINE
SECONDARY TREE
CONSERVATION AREA
10" DBH PINE
SECONDARY TREE
CONSERVATION AREA
12" DBH MAPLE
SECONDARY TREE
CONSERVATION AREA
12" DBH POPLAR
E
X
I
S
T
I
N
G
A
L
T
E
R
N
A
T
E
C
O
M
P
L
I
A
N
C
E
T
R
E
E
C
O
N
S
E
R
V
A
T
I
O
N
A
R
E
A
3
2
'
P
E
R
I
M
E
T
E
R
Y
A
R
D
(
0
.
1
1
A
c
.
)
P
E
R
M
I
T
#
1
0
6
4
5
P
E
R
M
A
N
E
N
T
L
Y
P
R
E
S
E
R
V
E
D
U
N
D
I
S
T
U
R
B
E
D
O
P
E
N
S
P
A
C
E
B
O
M
2
0
0
7
P
G
2
1
2
0
E
X
I
S
T
I
N
G
S
E
C
O
N
D
A
R
Y
T
R
E
E
C
O
N
S
E
R
V
A
T
I
O
N
A
R
E
A
6
5
'
W
I
D
E
P
E
R
I
M
E
T
E
R
Y
A
R
D
(
0
.
2
7
A
c
.
)
P
E
R
M
I
T
#
1
0
6
4
5
P
E
R
M
A
N
E
N
T
L
Y
P
R
E
S
E
R
V
E
D
U
N
D
I
S
T
U
R
B
E
D
O
P
E
N
S
P
A
C
E
B
O
M
2
0
0
7
P
G
2
1
2
0
I
X
-
3
I
X
-
4
-
P
L
-
C
U
Z
O
N
I
N
G
L
I
M
I
T
S
ZO
NIN
G L
IMIT
S
I
X
-
4
-
P
L
-
C
U
C
X
-
3
-
P
L
N/F
HERBERT & DORIS MASON
DB 02992, PG. 0722
ZONING: R-6
USE: SINGLE FAMILY
5803 OAK FOREST DRIVE
PIN #: 1726281429
N/F
AUDREY D. ROCHELLE
DB 07808, PG. 0222
ZONING: R-6
USE: SINGLE FAMILY
5805 OAK FOREST DRIVE
PIN #: 1726282398
N/F
MARY B. JORDAN
DB 11284, PG. 1848
ZONING: R-6
USE: SINGLE FAMILY
5813 OAK FOREST DRIVE
PIN #: 1726284332
N/F
WADE GARY STONE
DB 10309, PG. 2087
ZONING: R-6
USE: SINGLE FAMILY
5812 FOREST DRIVE
PIN #: 1726287209
N/F
JIMMY M. LYNCH
DB 11190, PG. 0035
ZONING: R-6
USE: SINGLE FAMILY
5705 FOREST DRIVE
PIN #: 1726289239
N/F
ROBERT T. HEDRICK
DB 14765, PG. 1931
ZONING: IX-4-PL-CU
USE: VACANT
0 OAK FOREST DRIVE
PIN #: 1726286588
N/F
SCHMALZ PROPERTY USA, LLC
DB 15728, PG. 2098
ZONING: IX-4-PL-CU
USE: WAREHOUSE
5850 OAK FOREST DRIVE
PIN #: 1726292078
N/F
MLC AUTOMOTIVE, LLC
DB 12603, PG. 2676
ZONING: CX-3-PL
USE: AUTOMOBILE DEALERSHIP
5603 CAPITAL BLVD.
PIN #: 1726285848
N/F
MLC AUTOMOTIVE, LLC
DB 12603, PG. 2676
ZONING: CX-3-PL
USE: VACANT
5603 CAPITAL BLVD.
PIN #: 1726285848
N/F
MLC AUTOMOTIVE, LLC
DB 12603, PG. 2676
ZONING: IX-4-PL-CU
USE: VACANT
5603 CAPITAL BLVD.
PIN #: 1726285848
335
**
**
*
PRE-DEV POINTCONTRIBUTORYBOUNDARY (TYP)
PRE-DEV POINTCONTRIBUTORYBOUNDARY (TYP)
POINT #3
POINT #2
POINT #1
POINT #4
POINT #5
Existing Conditions
OWNER:
(919) 876-5432
Raleigh, NC 27616
5601 Capital Blvd.
MLC Automotive, LLC
1" = 100'
CS - 3
ALL CONSTRUCTION SHALL BE IN STRICT
ACCORDANCE WITH CURRENT CITY OF RALEIGH
AND/OR NCDOT STANDARDS AND SPECIFICATIONS.
C-0329
February 3, 2017
NOTES:1. ALL CONSTRUCTION TO BE IN STRICT ACCORDANCE WITH CURRENT CITY OF RALEIGH AND/ORNCDOT STANDARDS AND SPECIFICATIONS.2. BOUNDARY INFORMATION IS TAKEN FROM SURVEY PERFORMED BY M-III SURVEYING.3. CONTOURS & PLANIMETRICS WERE OBTAINED FROM WAKE COUNTY GIS & COMPILED WITHSURVEYS BY M-III SURVEYING.4. TREELINE WAS OBTAINED FROM WAKE COUNTY GIS, AND MODIFIED BASED ON RECENT AERIALPHOTOS.5. NEUSE BUFFER AND WETLANDS DELINEATION IS FROM DATA DERIVED FROM USGS QUAD SHEETSAND WAKE COUNTY SOILS MAPS.6. THIS SITE IS NOT FEMA MAPPED.7. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING UTILITIES.8. ALL DISTANCES ARE TO BACK OF CURB OR RIGHT-OF-WAY UNLESS OTHERWISE SPECIFIED.9. MINIMUM CORNER CLEARANCE FROM THE CURB LINE OF INTERSECTING STREETS SHALL BE ATLEAST 20 FEET FROM THE POINT OF TANGENCY AND NO DRIVEWAY OR PARKING SPACES SHALLENCROACH ON THIS MINIMUM CORNER CLEARANCE.10. RIGHT-OF-WAY SHALL BE CLEARED AND GRUBBED WITHIN 100 FEET OF ALL STREETINTERSECTIONS.11. NO SIGHT OBSTRUCTING OR PARTIALLY OBSTRUCTING WALL, FENCE, FOLIAGE, BERM, PARKEDVEHICLES, SIGN OR OTHER OBJECTS BETWEEN THE HEIGHTS OF TWO (2) FEET AND EIGHT (8) FEETABOVE THE CURB LINE ELEVATION, OR THE NEAREST TRAVELED WAY IF NO CURBING EXISTS, SHALLBE PLACED WITHIN A SIGHT TRIANGLE.12. WC ACCESS RAMPS WILL BE PROVIDED IN ACCORDANCE WITH RALEIGH ENGINEERING STANDARDDRAWING T-20.01.2 & T-20.01.6.
Leith Auto Center Lot 2
Bldg Addition & Parking
Expansion
5603 Capital Boulevard
5800 Oak Forest Drive
CS-4
OWNER:
1" = 40'
(919) 876-5432
Raleigh, NC 27616
5601 Capital Blvd.
MLC Automotive, LLC
C-0329
Site Plan
April 19, 2017
ALL CONSTRUCTION SHALL BE IN STRICT
ACCORDANCE WITH CURRENT CITY OF RALEIGH
AND/OR NCDOT STANDARDS AND SPECIFICATIONS.
NOTES:1. ALL CONSTRUCTION TO BE IN STRICT ACCORDANCE WITH CURRENT CITY OFRALEIGH AND/OR NCDOT STANDARDS AND SPECIFICATIONS.2. BOUNDARY INFORMATION IS TAKEN FROM SURVEY PERFORMED BY M-III SURVEYING.3. CONTOURS & PLANIMETRICS WERE OBTAINED FROM WAKE COUNTY GIS & COMPILEDWITH SURVEYS BY M-III SURVEYING.4. TREELINE WAS OBTAINED FROM WAKE COUNTY GIS, AND MODIFIED BASED ONRECENT AERIAL PHOTOS.5. NEUSE BUFFER AND WETLANDS DELINEATION IS FROM DATA DERIVED FROM USGSQUAD SHEETS AND WAKE COUNTY SOILS MAPS.6. THIS SITE IS NOT FEMA MAPPED.7. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING UTILITIES.8. ALL DISTANCES ARE TO BACK OF CURB OR RIGHT-OF-WAY UNLESS OTHERWISESPECIFIED.9. MINIMUM CORNER CLEARANCE FROM THE CURB LINE OF INTERSECTING STREETSSHALL BE AT LEAST 20 FEET FROM THE POINT OF TANGENCY AND NO DRIVEWAY ORPARKING SPACES SHALL ENCROACH ON THIS MINIMUM CORNER CLEARANCE.10. RIGHT-OF-WAY SHALL BE CLEARED AND GRUBBED WITHIN 100 FEET OF ALL STREETINTERSECTIONS.11. NO SIGHT OBSTRUCTING OR PARTIALLY OBSTRUCTING WALL, FENCE, FOLIAGE,BERM, PARKED VEHICLES, SIGN OR OTHER OBJECTS BETWEEN THE HEIGHTS OF TWO (2)FEET AND EIGHT (8) FEET ABOVE THE CURB LINE ELEVATION, OR THE NEARESTTRAVELED WAY IF NO CURBING EXISTS, SHALL BE PLACED WITHIN A SIGHT TRIANGLE.12. WC ACCESS RAMPS WILL BE PROVIDED IN ACCORDANCE WITH RALEIGHENGINEERING STANDARD DRAWING T-20.01.2 & T-20.01.6.
Leith Auto Center Lot 2
Bldg Addition & Parking
Expansion
5603 Capital Boulevard
5800 Oak Forest Drive
PAVEMENT DESIGN NOTE:ALL PAVEMENT PROPOSED ON THIS PLAN IS TO BE8" ABC AND 3" S9.5B UNLESS OTHERWISE SPECIFIED.
SITE DATA
1726-28-5848
SITE ADDRESS: 5603 CAPITAL BLVD
& 5800 OAK FOREST ROAD
REQUIRED = 5 SPACES
PARKING CALCULATIONS FOR
PROPOSED WAREHOUSE & OFFICE ONLY
PARKING NOTE:
Since provided parking > 150% of required parking, interior
landscape islands and tree placements have been provided to
conform to sec. 7.1.2 D3.
9,632 sf @ 1 SP/3,000 sf = 4 SPACES
WAREHOUSE COMPONENT:
PROVIDED = 46 SPACES (Incl. 2 HC Spaces)
300 sf @ 1 SP/600 sf = 1 SPACES
WAREHOUSE COMPONENT:
Outdoor Amenity Calculations
10% of Site Area
Total Site Area = 14.03 Ac = 610,982 sf
Required Space = 1.40 Ac = 61,098 sf
Provided Space = 1.42 Ac = 61,737 sf
Build-To Calculations
50% of 399.53' (Site width at Oak Forest Drive)
Must have Building Facade (0'-100' from R/W)
Building Facade Required = 199.77'
Building Facade Provided = 200' (50.06%)
BICYCLE NOTE:
Bicycle spaces to be provided inside the warehouse building
REQUIRED = 4 LONG TERM
PROVIDED = 4 LONG TERM (SEE NOTE BELOW)
BICYCLE SPACES:
OPEN SPACE AMENITY
LOCATION KEY
SCALE 1" = 200'
Note:
All outdoor amenity areas are ADA
accessible via existing hardscape/walks
or by proposed concrete pads and
depressed curbs.
CS-5
OWNER:
1" = 40'
(919) 876-5432
Raleigh, NC 27616
5601 Capital Blvd.
MLC Automotive, LLC
C-0329
Utility Plan
February 3, 2017
ALL CONSTRUCTION SHALL BE IN STRICT
ACCORDANCE WITH CURRENT CITY OF RALEIGH
AND/OR NCDOT STANDARDS AND SPECIFICATIONS.
UTILITY DATA:
STANDARD UTILITY NOTES (as applicable):
1. All materials & construction methods shall be in accordance with City of Raleigh design
standards, details & specifications (reference: CORPUD Handbook, current edition)
2. Utility separation requirements:
a) A distance of 100’ shall be maintained between sanitary sewer & any private or public
water supply source such as an impounded reservoir used as a source of drinking water. If
adequate lateral separation cannot be achieved, ferrous sanitary sewer pipe shall be
specified & installed to waterline specifications. However, the minimum separation shall
not be less than 25’ from a private well or 50’ from a public well
b) When installing water &/or sewer mains, the horizontal separation between utilities shall
be 10’. If this separation cannot be maintained due to existing conditions, the variation
allowed is the water main in a separate trench with the elevation of the water main at
least 18” above the top of the sewer & must be approved by the Public Utilities Director.
All distances are measured from outside diameter to outside diameter
c) Where it is impossible to obtain proper separation, or anytime a sanitary sewer passes
over a watermain, DIP materials or steel encasement extended 10’ on each side of
crossing must be specified & installed to waterline specifications
d) 5.0’ minimum horizontal separation is required between all sanitary sewer & storm sewer
facilities, unless DIP material is specified for sanitary sewer
e) Maintain 18” min. vertical separation at all watermain & RCP storm drain crossings;
maintain 24” min. vertical separation at all sanitary sewer & RCP storm drain crossings.
Where adequate separations cannot be achieved, specify DIP materials & a concrete
cradle having 6” min. clearance (per CORPUD details W-41 & S-49)
f) All other underground utilities shall cross water & sewer facilities with 18” min. vertical
separation required
3. Any necessary field revisions are subject to review & approval of an amended plan &/or profile by
the City of Raleigh Public Utilities Department prior to construction
4. Contractor shall maintain continuous water & sewer service to existing residences & businesses
throughout construction of project. Any necessary service interruptions shall be preceded by a 24
hour advance notice to the City of Raleigh Public Utilities Department
5. 3.0’ minimum cover is required on all water mains & sewer forcemains. 4.0’ minimum cover is
required on all reuse mains
6. It is the developer’s responsibility to abandon or remove existing water & sewer services not being
used in redevelopment of a site unless otherwise directed by the City of Raleigh Public Utilities
Department. This includes abandoning tap at main & removal of service from ROW or easement
per CORPUD Handbook procedure
7. Install 6" DIP water services with meters located at ROW or within a 2’x2’ Waterline
Easement immediately adjacent. NOTE: it is the applicant’s responsibility to properly size the
water service for each connection to provide adequate flow & pressure
8. Install 4" and 6” PVC sewer services @ 1.0% minimum grade with cleanouts located at ROW or
easement line & spaced every 75 linear feet maximum
9. Pressure reducing valves are required on all water services exceeding 80 psi; backwater valves are
required on all sanitary sewer services having building drains lower than 1.0’ above the next
upstream manhole
10. All environmental permits applicable to the project must be obtained from NCDWQ, USACE
&/or FEMA for any riparian buffer, wetland &/or floodplain impacts (respectively) prior to
construction.
11. NCDOT / Railroad Encroachment Agreements are required for any utility work (including main
extensions & service taps) within state or railroad ROW prior to construction
12. Grease Interceptor / Oil Water Separator sizing calculations & installation specifications shall be
approved by the CORPUD FOG Program Coordinator prior to issuance of a Building Permit.
Contact Tim Beasley at (919) 996-2334 or [email protected] for more information
13. Cross-connection control protection devices are required based on degree of health hazard
involved as listed in Appendix-B of the Rules Governing Public Water Systems in North Carolina.
These guidelines are the minimum requirements. The devices shall meet American Society of
Sanitary Engineering (ASSE) standards or be on the University of Southern California approval
list. The devices shall be installed and tested (both initial and periodic testing thereafter) in
accordance with the manufacturer’s recommendations or the local cross-connection control
program, whichever is more stringent. Contact Joanie Hartley at (919) 996-5923 or
1. [email protected] for more information
Leith Auto Center Lot 2
Bldg Addition & Parking
Expansion
5603 Capital Boulevard
5800 Oak Forest Drive
CS - 7
OWNER:
1" = 40'
(919) 876-5432
Raleigh, NC 27616
5601 Capital Blvd.
MLC Automotive, LLC
C-0329
February 3, 2017
ALL CONSTRUCTION SHALL BE IN STRICT
ACCORDANCE WITH CURRENT CITY OF RALEIGH
AND/OR NCDOT STANDARDS AND SPECIFICATIONS.
Landscape Plan
= PROPOSED NAME OF PLANT & NUMBER OF PLANTS.
#
NAME
NOTE:
ALL DISTURBED AREAS OUTSIDE OF TCA'S
AND MULCH BEDS FOR PLANTING ARE TO BE GRASSED.
CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL LANDSCAPE
MATERIAL COUNTS SHOWN ON THESE PLANS.
Leith Auto Center Lot 2
Bldg Addition & Parking
Expansion
5603 Capital Boulevard
5800 Oak Forest Drive
WHOLESALE PARTS STORAGE
COVERED CANOPY
54'-0
"
71'-8
5 8"
GENERAL STORAGE
200'-0"
136'-434"
1'-0
"
1'-0"
1'-0"658"
35'-838" 32'-6" 32'-6" 35'-83
8"1'-6"
29'-6" 29'-6"
1'-0"
658"
34'-0
"18
'-0"
17'-0
"
PROPOSED WALL LOCATION
These drawings are the property of Winstead Wilkinson Architects, PLLC. They may not be reused for any purpose without written permission. Copyright © 2017 by Winstead Wilkinson Architects, PLLC. All rights reserved.
1848 Wake Forest RoadRaleigh, NC 27608
t. 919-832-2878f. 919-832-7901
LEITH
WHO
LESA
LEPA
RTS
PROJECT NUMBER
DATE
REVISIONS
217102
FEBRUARY 2, 2017
New
Can
opy
for:
RALE
IGH,
NO
RTH
CA
ROLI
NA
A100
ELEVATIONS
1 REVISION 1 - 8/7/17
111
1FLOOR PLANSCALE: 1/8" = 1'-0"
2
2
2 REVISION 2 - 9/7/17
CPEFIS
CMU
17'-7"
CB
EP-1
CB
EP-1 CMUCMU
EFISEFIS
CMU SF1SF1 SF1CMU 2 CMU 2 CMU 2
7'-0
"
LONGEST BLANK WALL 12.5'ELEVATION NOTES
BUILDING ELEVATION=3,045 SF (20% REQUIRED TRANSPARENCY)=609 SF PROVIDED 908 SF
12'-0
"
CMU
EFIS CP
EP-1
CB
12'-0
"
17'-7
"
CMU
EFISCP
EP-1
CB
These drawings are the property of Winstead Wilkinson Architects, PLLC. They may not be reused for any purpose without written permission. Copyright © 2017 by Winstead Wilkinson Architects, PLLC. All rights reserved.
1848 Wake Forest RoadRaleigh, NC 27608
t. 919-832-2878f. 919-832-7901
LEITH
WHO
LESA
LEPA
RTS
PROJECT NUMBER
DATE
REVISIONS
217102
FEBRUARY 2, 2017
New
Can
opy
for:
RALE
IGH,
NO
RTH
CA
ROLI
NA
2ELEVATIONSCALE: 1/8" = 1'-0"
1ELEVATIONSCALE: 1/8" = 1'-0"
3OAK FOREST ROAD ELEVATIONSCALE: 1/8" = 1'-0"
4ELEVATIONSCALE: 1/8" = 1'-0"
A101
ELEVATIONS
1 REVISION 1 - 8/7/17
111
2 REVISION 2 - 9/7/17
2
2