LEITH AUTO CENTER BUILDING EXPANSION SR-16-2017 AUTO CENTER BUILDING EXPANSION ¯ SR-16-2017! ......

11
CAPITAL BLVD OAK FOREST DR HICKORY RD SUMNER BLVD OLD WAKE FOREST RD DOGWOOD DR TRUST DR DEPARTURE DR FOREST DR BARROW DR TANGLEWOOD DR MELVILLE DR MORGANTOWN ST CLARKSBURG PL PARKERSBURG ST CAPITAL BLVD SUMNER BLVD Zoning: CAC: Drainage Basin: Acreage: Sq. Ft.: IX-3, CX-3-PL, IX-4-PL-CU North Marsh Creek 14.03 44,107 0 600 1,200 300 Feet Planner: Phone: Applicant: Phone: Daniel Stegall (919) 996-2712 Bill Daniel (919) 467-9708 ¯ LEITH AUTO CENTER BUILDING EXPANSION SR-16-2017 !

Transcript of LEITH AUTO CENTER BUILDING EXPANSION SR-16-2017 AUTO CENTER BUILDING EXPANSION ¯ SR-16-2017! ......

Page 1: LEITH AUTO CENTER BUILDING EXPANSION SR-16-2017 AUTO CENTER BUILDING EXPANSION ¯ SR-16-2017! ... AUTOMOBILE DEALERSHIP N/F ... These plans have been reviewed by the design engineer

CAPITAL BLVD

OAK FOREST DR

HICKORY RD

SUMNER BLVD

OLD WAKE FOREST RDDO

GWOO

D DR

TRUST DR

DEPA

RTUR

E DR

FORE

ST D

R

BARROW DR

TANG

LEWO

OD D

R

MELV

ILLE D

R

MORGANTOWN STCLARKSBURG PL

PARKERSBURG ST

CAPITAL BLVD

SUMNER BLVD

Zoning:CAC:

Drainage Basin:Acreage:

Sq. Ft.:

IX-3, CX-3-PL,IX-4-PL-CUNorthMarsh Creek14.0344,107

0 600 1,200300 Feet

Planner:Phone:

Applicant:Phone:

Daniel Stegall(919) 996-2712Bill Daniel(919) 467-9708

¯LEITH AUTO CENTER BUILDING EXPANSIONSR-16-2017

!

Page 2: LEITH AUTO CENTER BUILDING EXPANSION SR-16-2017 AUTO CENTER BUILDING EXPANSION ¯ SR-16-2017! ... AUTOMOBILE DEALERSHIP N/F ... These plans have been reviewed by the design engineer
Page 3: LEITH AUTO CENTER BUILDING EXPANSION SR-16-2017 AUTO CENTER BUILDING EXPANSION ¯ SR-16-2017! ... AUTOMOBILE DEALERSHIP N/F ... These plans have been reviewed by the design engineer
Page 4: LEITH AUTO CENTER BUILDING EXPANSION SR-16-2017 AUTO CENTER BUILDING EXPANSION ¯ SR-16-2017! ... AUTOMOBILE DEALERSHIP N/F ... These plans have been reviewed by the design engineer
Page 5: LEITH AUTO CENTER BUILDING EXPANSION SR-16-2017 AUTO CENTER BUILDING EXPANSION ¯ SR-16-2017! ... AUTOMOBILE DEALERSHIP N/F ... These plans have been reviewed by the design engineer

CAPITAL BOULEVARD (NORTHBOUND LANE)

T

A

N

G

L

E

W

O

O

D

CAPITAL BOULEVARD (SOUTHBOUND LANE)

ROBERT T. HEDRICK

DB 11520, PG. 1334

ZONING: IX-4-PL-CU

USE: SINGLE FAMILY

N/F

MLC AUTOMOTIVE, LLC

DB 11798, PG. 1210

ZONING: CX-3-PL

USE: VACANT

N/F

KENNETH D. KENNEDY

DB 02961, PG. 0707

ZONING: IND-1

USE: FLEX WAREHOUSE

N/F

CLARENCE & LIBBY JONES

DB 1575, PG. 696

ZONING: R-6

USE: SINGLE FAMILY

N/F

CLAUDE E. PERRY

DB 1572, PG. 233

ZONING: R-6

USE: SINGLE FAMILY

N/F

HEDRICK, ROBERT T.

DB 11520, PG. 1340

ZONING: IX-3

USE: VACANT

N/F

D

R

IV

E

GOLD MOON, LLC

DB 8980, PG. 1819

ZONING: IND-1

USE: AUTOMOBILE DEALERSHIP

N/F

ARGONAUT HOLDINGS INC C/O

DB 9556, PG. 851

ZONING: CUD BUS

USE: SALES & SERVICE

N/F

WORLDWIDE REAL ESTATE

EDWARD GREEN

DB 11083, PG. 100

ZONING: R-6

USE: VACANT

N/F

EDWARD GREEN

DB 11083, PG. 100

ZONING: R-6

USE: SINGLE FAMILY

N/F

JIMMY LYNCH

DB 11190, PG. 0035

ZONING: R-6

USE: SINGLE FAMILY

N/F

NC ELECTRIC MEMBERSHIP CORP.

DB 03164, PG. 898

ZONING: TD

USE: OFFICE

N/F

NC ELECTRIC MEMBERSHIP CORP.

DB 03480, PG. 411

ZONING: TD

USE: FLEX WAREHOUSE

N/F

HUDSON HAINES, JR.

DB 03334, PG. 457

ZONING: TD

USE: COMMERCIAL

N/F

SSC ACQUISITIONS INC

DB 06265, PG. 200

ZONING: TD

USE: MINI-WAREHOUSE

N/F

ONEAL NORTH RALEIGH

DB 03613, PG. 0396

ZONING: TD

USE: OFFICE

N/F

ONEAL NORTH RALEIGH

DB 03613, PG. 0396

ZONING: TD

USE: OFFICE

N/F

O

A

K

F

O

R

E

S

T

D

R

I

V

E

DR

IV

E

OA

K F

OR

ES

T

5850 OAK FOREST DRIVE

6700 WAKE FOREST ROAD

5909 CAPITAL BLVD.

5849 CAPITAL BLVD.

5839 CAPITAL BLVD.

3400 SUMNER BLVD.

5660 CAPITAL BLVD.

5640 CAPITAL BLVD.5602 CAPITAL BLVD.

5600 CAPITAL BLVD.

5501 OAK FOREST DRIVE

5501 CAPITAL BLVD.

5617 OAK FOREST DRIVE

5621 OAK FOREST DRIVE

5705 OAK FOREST DRIVE

5700 OAK FOREST DRIVE

5603 CAPITAL BOULEVARD

25

.0

'

PIN #: 1726288599

PIN #: 1726392217

PIN #: 1726291032

PIN #: 1727202654

PIN #: 1727302309

PIN #: 1727302289

PIN #: 1727304088

PIN #: 1726491980

PIN #: 1726492472

PIN #: 1726492200PIN #: 1726482908

PIN #: 1726481798

PIN #: 1726483612

PIN #: 1726386421

PIN #: 1726383471

PIN #: 1726382355

PIN #: 1726289239

EXISTING CAPITAL BLVD. (US 1)

(200' PUBLIC R/W)

(

E

X

.

6

0

'

P

U

B

L

I

C

R

/

W

)

MLC AUTOMOTIVE, LLC

BOM 2016 PG 214&215

ZONING: CX-3-PL

USE: AUTOMOBILE DEALERSHIP

5603 CAPITAL BLVD.

(LOT 2)

PARCEL BOUNDARY

20

0.0

0'

47

.0

'

45

.7

'

10

0.0

0'

64.9'

TBM

N = 769,821.4792

E = 2,123,722.3579

ELEV. 307.39 (NAVD 88)

20

0.0

0'

46

.3

'

65.7'

(LOT 1)

PARCEL BOUNDARY

F

O

R

E

S

T

D

R

IV

E

D

O

G

W

O

O

D

D

R

I

V

E

N/F

ROBERT T. HEDRICK

DB 14765, PG. 1931

ZONING: IX-4-PL-CU

USE: VACANT

0 OAK FOREST DRIVE

PIN #: 1726286588

1.93 ACRES

MLC AUTOMOTIVE, LLC

BOM 2016 PG 1089

ZONING: CX-3-PL

MLC AUTOMOTIVE, LLC

BOM 2016 PG 1089

ZONING: CX-3-PL

USE: AUTOMOBILE DEALERSHIP

HIGH INTENSITY

HIGH INTENSITY

HIGH INTENSITY

HIGH INTENSITY

O

A

K

F

O

R

E

S

T

D

R

I

V

E

MLC AUTOMOTIVE, LLC

DB 11798, PG. 1210

ZONING: CX-3-PL

USE: VACANT

N/F

5605 CAPITAL BOULEVARD

PIN #: 1726284874

MLC AUTOMOTIVE, LLC

DB 11798, PG. 1210

ZONING: IX-3

USE: VACANT

N/F

5603 CAPITAL BOULEVARD

PIN #: 1726392217

MLC AUTOMOTIVE, LLC

DB 11798, PG. 1210

ZONING: IX-4-PL-CU

USE: VACANT

N/F

5603 CAPITAL BOULEVARD

PIN #: 1726392217

HIGH INTENSITY

HIGH INTENSITY

N/F

SCHMALZ PROPERTY USA, LLC

DB 15728, PG. 2098

ZONING: IX-3

USE: WAREHOUSE

5850 OAK FOREST DRIVE

PIN #: 1726292078

N/F

SCHMALZ PROPERTY USA, LLC

DB 15728, PG. 2098

ZONING: IX-3

USE: WAREHOUSE

5850 OAK FOREST DRIVE

PIN #: 1726292078

MLC Automotive, LLC

5601 Capital Blvd.

Raleigh, NC 27616

(919) 876-5432

1" = 100'

OWNER:

Cover

GRADING, STORM, & EROSION CONTROL PLAN

PUBLIC IMPROVEMENT QUANTITIES

PUBLIC SEWER 0 LF

0 LFPUBLIC WATER

PUBLIC STREET 400 LF

PUBLIC SIDEWALK 362 LF

# OF LOTS 1 (Existing)

LOT # 2

EXISTING CONDITIONS PLAN

DETAILS

DESCRIPTIONSHEET NO.COVERCS-1

SITE PLAN

BOM 2016 PAGE 214CS-2

CS-3CS-4

CS-1

CS-5

CS-7

CS-6

LANDSCAPE PLAN

VICINITY MAP

1" = 1000'

O

L

D

W

A

K

E

F

O

R

E

S

T

R

O

A

D

C

AP

IT

AL B

LV

D

.

O

A

K

S

U

M

N

E

R

B

L

V

D

.

S

U

M

N

E

R

B

L

V

D

.

F

O

R

E

S

T

D

R

.

SITE

D

E

P

A

R

T

U

R

E

D

R

.

February 3, 2017

C-0329

[email protected]

Preliminary Plan

CS-10

BOM 2016 PAGE 215CS-2a

BLOCK PERIMETER CALCULATION

Solid Waste Compliance Statement:These plans have been reviewed by the design engineerand developer and are in compliance with therequirements set forth in the Solid Waste Design Manual.

PROJECT NOTE:THIS PLAN PROPOSES A BUILDINGADDITION W/ SUPPORTINGINFRASTRUCTURE AND LIMITEDOUTDOOR STORAGE FOR AN EXISTINGAUTOMOBILE DEALERSHIP. NO CHANGEIN SITE USE PROPOSED ON THIS PLAN.

CS-8 LANDSCAPE DETAILSCS-9

SOLID WASTE SERVICES PLAN

Lot 2 Expansion

Impervious Area Data

Existing Conditions:

VSA 184,694sf (4.24ac)

Building 40,753sf (0.94ac)

Existing Total: 225,447sf (5.18ac)

Proposed Conditions:

VSA 334,976sf (7.69ac)

Building 50,685sf (1.17ac)

Proposed Total: 385,661sf (8.86ac)

This plan proposes an increase to impervious

area by 160,214 sf (3.68 ac).

EXISTING BLOCK PERIMETER = 11,120 lf

MAX BLOCK PERIMETER = 4,000 lf

ZONING: IX-4-PL-CU, IX-3, & CX-3-PL

NOTE:

A DESIGN ADJUSTMENT WILL BE

SUBMITTED

TREE CONSERVATION AREA PLAN

LOT 2

DETAILSCS-11

Leith Auto Center Lot 2

Bldg Addition & Parking

Expansion

5603 Capital Boulevard

5800 Oak Forest Drive

SITE PLAN

DETAILSCS-12CS-13

ISOLUX PLAN

LIMITED OUTDOOR

STORAGE

BLDG.

ADDITION

W/ PARKING

ALL CONSTRUCTION SHALL BE IN STRICT

ACCORDANCE WITH CURRENT CITY OF RALEIGH

AND/OR NCDOT STANDARDS AND SPECIFICATIONS.

1 of 1

NPDES SECIFIC PLANCS-6.1

TR

AN

SA

CT

IO

N #

50

31

71

SR-16-17

SCM DETAILSCS-14

BUILDING FLOOR PLANA100BUILDING ELEVATIONSA101

5.18 ac

8.86 ac

9,932 sf

50,685 sf

Page 6: LEITH AUTO CENTER BUILDING EXPANSION SR-16-2017 AUTO CENTER BUILDING EXPANSION ¯ SR-16-2017! ... AUTOMOBILE DEALERSHIP N/F ... These plans have been reviewed by the design engineer

320

330

ROBERT T. HEDRICK

DB 11520, PG. 1334

ZONING: IX-4-PL-CU

USE: SINGLE FAMILY

N/F

HEDRICK, ROBERT T.

DB 11520, PG. 1340

ZONING: CUD IND-1 & IND-1

USE: VACANT

N/F

KENNETH D. KENNEDY

DB 02961, PG. 0707

ZONING: IND-1

USE: FLEX WAREHOUSE

N/F

HEDRICK, ROBERT T.

DB 11520, PG. 1340

ZONING: CUD IND-1 & IND-1

USE: VACANT

N/F

GOLD MOON, LLC

DB 8980, PG. 1819

ZONING: IND-1

USE: AUTOMOBILE DEALERSHIP

N/F

5606 OAK FOREST DRIVE.

ZONING: CX-3-PL

BOM 2016 PG 214&215

MLC AUTOMOTIVE, LLC

332

334

336

328

326

324

322

318

25

.0

'

CLAUDE E. PERRY

DB 1572, PG. 233

ZONING: R-6

USE: SINGLE FAMILY

N/F

5849 CAPITAL BLVD.

PROPERTY LINE &

PROJECT BOUNDARY

330

320

PROPERTY LINE &

PROJECT BOUNDARY

PERMANENTLY

PRESERVED

UNDISTURBED

OPEN SPACE

SECONDARY TREE

CONSERVATION AREA

65' PERIMETER YARD

(0.30 Ac.)

PERMIT # 10644

OPEN SPACE

UNDISTURBED

PRESERVED

PERMANENTLY

ALTERNATE

COMPLIANCE

SECONDARY TREE

CONSERVATION AREA

32' PERIMETER YARD

(0.84 Ac.)

PERMIT # 10644

PERMANENTLY

PRESERVED

UNDISTURBED

OPEN SPACE

EXISTING

ALTERNATE

COMPLIANCE

SECONDARY TREE

CONSERVATION AREA

32' PERIMETER YARD

(0.44 Ac.)

PERMIT # 10645

BOM 2007 PG 2120

PROP. 6" TA

PPING

SLEEVE W

ITH VA

LVE

6" DIP

FIRELINE

FDC

CURB & PARKING

SHIFTED 2.15' SOUTH

2.15'

2.5'R

5'R5'RARGONAUT HOLDINGS INC C/O

DB 9556, PG. 851

ZONING: CUD BUS

USE: SALES & SERVICE

N/F

WORLDWIDE REAL ESTATE

5501 CAPITAL BLVD.

30.7'

EDWARD GREEN

DB 11083, PG. 100

ZONING: R-6

USE: SINGLE FAMILY

N/F

5621 OAK FOREST DRIVE

EDWARD GREEN

DB 11083, PG. 100

ZONING: R-6

USE: VACANT

N/F

5617 OAK FOREST DRIVE

ONEAL NORTH RALEIGH

DB 03613, PG. 0396

ZONING: TD

USE: OFFICE

N/F

5501 OAK FOREST DRIVE

20

3.4

'

5600 CAPITAL BLVD.

N/F

USE: OFFICE

ZONING: TD

DB 03613, PG. 0396

ONEAL NORTH RALEIGH

64.8'

46

.4

'

5602 CAPITAL BLVD.

N/F

USE: MINI-WAREHOUSE

ZONING: TD

DB 06265, PG. 200

SSC ACQUISITIONS INC

5640 CAPITAL BLVD.

N/F

USE: COMMERCIAL

ZONING: TD

DB 03334, PG. 457

HUDSON HAINES, JR.

23

.6

'

MLC AUTOMOTIVE, LLC

BOM 2016 PG 214&215

ZONING: IND-1

USE: AUTOMOBILE DEALERSHIP

5603 CAPITAL BLVD.

5601 CAPITAL BLVD.

USE: AUTOMOBILE DEALERSHIP

ZONING: CX-3-PL

BOM 2016 PG 214&215

MLC AUTOMOTIVE, LLC

NEW PROPERTY LINE TO BE ESTABLISHED VIA RECOMBINATION PLAT

EX. PROPERTY LINE TO BE REMOVED VIA RECOMBINATION PLAT

LOW INTENSITY

HIGH INTENSITY

HIGH INTENSITY

HIGH INTENSITY

SECONDARY TREE

CONSERVATION AREA

11" DBH PINE

FLO

OD

P

RO

NE

A

RE

A LIM

IT

S

(F

RO

M C

OR

IM

AP

S)

5

0

'

5

0

'

E

X

.

N

R

B

FLO

O

D

P

R

O

N

E A

R

EA

LIM

IT

S

(F

R

O

M

C

O

R

IM

AP

S)

E

X

. N

R

B

SECONDARY TREE

CONSERVATION AREA

11" DBH SWEET GUM

SECONDARY TREE

CONSERVATION AREA

13" DBH SWEET GUM

SECONDARY TREE

CONSERVATION AREA

12" DBH SWEET GUM

SECONDARY TREE

CONSERVATION AREA

10" DBH PINE

SECONDARY TREE

CONSERVATION AREA

13" DBH PINE

SECONDARY TREE

CONSERVATION AREA

10" DBH PINE

SECONDARY TREE

CONSERVATION AREA

12" DBH MAPLE

SECONDARY TREE

CONSERVATION AREA

12" DBH POPLAR

E

X

I

S

T

I

N

G

A

L

T

E

R

N

A

T

E

C

O

M

P

L

I

A

N

C

E

T

R

E

E

C

O

N

S

E

R

V

A

T

I

O

N

A

R

E

A

3

2

'

P

E

R

I

M

E

T

E

R

Y

A

R

D

(

0

.

1

1

A

c

.

)

P

E

R

M

I

T

#

1

0

6

4

5

P

E

R

M

A

N

E

N

T

L

Y

P

R

E

S

E

R

V

E

D

U

N

D

I

S

T

U

R

B

E

D

O

P

E

N

S

P

A

C

E

B

O

M

2

0

0

7

P

G

2

1

2

0

E

X

I

S

T

I

N

G

S

E

C

O

N

D

A

R

Y

T

R

E

E

C

O

N

S

E

R

V

A

T

I

O

N

A

R

E

A

6

5

'

W

I

D

E

P

E

R

I

M

E

T

E

R

Y

A

R

D

(

0

.

2

7

A

c

.

)

P

E

R

M

I

T

#

1

0

6

4

5

P

E

R

M

A

N

E

N

T

L

Y

P

R

E

S

E

R

V

E

D

U

N

D

I

S

T

U

R

B

E

D

O

P

E

N

S

P

A

C

E

B

O

M

2

0

0

7

P

G

2

1

2

0

I

X

-

3

I

X

-

4

-

P

L

-

C

U

Z

O

N

I

N

G

L

I

M

I

T

S

ZO

NIN

G L

IMIT

S

I

X

-

4

-

P

L

-

C

U

C

X

-

3

-

P

L

N/F

HERBERT & DORIS MASON

DB 02992, PG. 0722

ZONING: R-6

USE: SINGLE FAMILY

5803 OAK FOREST DRIVE

PIN #: 1726281429

N/F

AUDREY D. ROCHELLE

DB 07808, PG. 0222

ZONING: R-6

USE: SINGLE FAMILY

5805 OAK FOREST DRIVE

PIN #: 1726282398

N/F

MARY B. JORDAN

DB 11284, PG. 1848

ZONING: R-6

USE: SINGLE FAMILY

5813 OAK FOREST DRIVE

PIN #: 1726284332

N/F

WADE GARY STONE

DB 10309, PG. 2087

ZONING: R-6

USE: SINGLE FAMILY

5812 FOREST DRIVE

PIN #: 1726287209

N/F

JIMMY M. LYNCH

DB 11190, PG. 0035

ZONING: R-6

USE: SINGLE FAMILY

5705 FOREST DRIVE

PIN #: 1726289239

N/F

ROBERT T. HEDRICK

DB 14765, PG. 1931

ZONING: IX-4-PL-CU

USE: VACANT

0 OAK FOREST DRIVE

PIN #: 1726286588

N/F

SCHMALZ PROPERTY USA, LLC

DB 15728, PG. 2098

ZONING: IX-4-PL-CU

USE: WAREHOUSE

5850 OAK FOREST DRIVE

PIN #: 1726292078

N/F

MLC AUTOMOTIVE, LLC

DB 12603, PG. 2676

ZONING: CX-3-PL

USE: AUTOMOBILE DEALERSHIP

5603 CAPITAL BLVD.

PIN #: 1726285848

N/F

MLC AUTOMOTIVE, LLC

DB 12603, PG. 2676

ZONING: CX-3-PL

USE: VACANT

5603 CAPITAL BLVD.

PIN #: 1726285848

N/F

MLC AUTOMOTIVE, LLC

DB 12603, PG. 2676

ZONING: IX-4-PL-CU

USE: VACANT

5603 CAPITAL BLVD.

PIN #: 1726285848

335

**

**

*

PRE-DEV POINTCONTRIBUTORYBOUNDARY (TYP)

PRE-DEV POINTCONTRIBUTORYBOUNDARY (TYP)

POINT #3

POINT #2

POINT #1

POINT #4

POINT #5

Existing Conditions

OWNER:

(919) 876-5432

Raleigh, NC 27616

5601 Capital Blvd.

MLC Automotive, LLC

1" = 100'

CS - 3

ALL CONSTRUCTION SHALL BE IN STRICT

ACCORDANCE WITH CURRENT CITY OF RALEIGH

AND/OR NCDOT STANDARDS AND SPECIFICATIONS.

C-0329

February 3, 2017

NOTES:1. ALL CONSTRUCTION TO BE IN STRICT ACCORDANCE WITH CURRENT CITY OF RALEIGH AND/ORNCDOT STANDARDS AND SPECIFICATIONS.2. BOUNDARY INFORMATION IS TAKEN FROM SURVEY PERFORMED BY M-III SURVEYING.3. CONTOURS & PLANIMETRICS WERE OBTAINED FROM WAKE COUNTY GIS & COMPILED WITHSURVEYS BY M-III SURVEYING.4. TREELINE WAS OBTAINED FROM WAKE COUNTY GIS, AND MODIFIED BASED ON RECENT AERIALPHOTOS.5. NEUSE BUFFER AND WETLANDS DELINEATION IS FROM DATA DERIVED FROM USGS QUAD SHEETSAND WAKE COUNTY SOILS MAPS.6. THIS SITE IS NOT FEMA MAPPED.7. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING UTILITIES.8. ALL DISTANCES ARE TO BACK OF CURB OR RIGHT-OF-WAY UNLESS OTHERWISE SPECIFIED.9. MINIMUM CORNER CLEARANCE FROM THE CURB LINE OF INTERSECTING STREETS SHALL BE ATLEAST 20 FEET FROM THE POINT OF TANGENCY AND NO DRIVEWAY OR PARKING SPACES SHALLENCROACH ON THIS MINIMUM CORNER CLEARANCE.10. RIGHT-OF-WAY SHALL BE CLEARED AND GRUBBED WITHIN 100 FEET OF ALL STREETINTERSECTIONS.11. NO SIGHT OBSTRUCTING OR PARTIALLY OBSTRUCTING WALL, FENCE, FOLIAGE, BERM, PARKEDVEHICLES, SIGN OR OTHER OBJECTS BETWEEN THE HEIGHTS OF TWO (2) FEET AND EIGHT (8) FEETABOVE THE CURB LINE ELEVATION, OR THE NEAREST TRAVELED WAY IF NO CURBING EXISTS, SHALLBE PLACED WITHIN A SIGHT TRIANGLE.12. WC ACCESS RAMPS WILL BE PROVIDED IN ACCORDANCE WITH RALEIGH ENGINEERING STANDARDDRAWING T-20.01.2 & T-20.01.6.

Leith Auto Center Lot 2

Bldg Addition & Parking

Expansion

5603 Capital Boulevard

5800 Oak Forest Drive

Page 7: LEITH AUTO CENTER BUILDING EXPANSION SR-16-2017 AUTO CENTER BUILDING EXPANSION ¯ SR-16-2017! ... AUTOMOBILE DEALERSHIP N/F ... These plans have been reviewed by the design engineer

CS-4

OWNER:

1" = 40'

(919) 876-5432

Raleigh, NC 27616

5601 Capital Blvd.

MLC Automotive, LLC

C-0329

Site Plan

April 19, 2017

ALL CONSTRUCTION SHALL BE IN STRICT

ACCORDANCE WITH CURRENT CITY OF RALEIGH

AND/OR NCDOT STANDARDS AND SPECIFICATIONS.

NOTES:1. ALL CONSTRUCTION TO BE IN STRICT ACCORDANCE WITH CURRENT CITY OFRALEIGH AND/OR NCDOT STANDARDS AND SPECIFICATIONS.2. BOUNDARY INFORMATION IS TAKEN FROM SURVEY PERFORMED BY M-III SURVEYING.3. CONTOURS & PLANIMETRICS WERE OBTAINED FROM WAKE COUNTY GIS & COMPILEDWITH SURVEYS BY M-III SURVEYING.4. TREELINE WAS OBTAINED FROM WAKE COUNTY GIS, AND MODIFIED BASED ONRECENT AERIAL PHOTOS.5. NEUSE BUFFER AND WETLANDS DELINEATION IS FROM DATA DERIVED FROM USGSQUAD SHEETS AND WAKE COUNTY SOILS MAPS.6. THIS SITE IS NOT FEMA MAPPED.7. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING UTILITIES.8. ALL DISTANCES ARE TO BACK OF CURB OR RIGHT-OF-WAY UNLESS OTHERWISESPECIFIED.9. MINIMUM CORNER CLEARANCE FROM THE CURB LINE OF INTERSECTING STREETSSHALL BE AT LEAST 20 FEET FROM THE POINT OF TANGENCY AND NO DRIVEWAY ORPARKING SPACES SHALL ENCROACH ON THIS MINIMUM CORNER CLEARANCE.10. RIGHT-OF-WAY SHALL BE CLEARED AND GRUBBED WITHIN 100 FEET OF ALL STREETINTERSECTIONS.11. NO SIGHT OBSTRUCTING OR PARTIALLY OBSTRUCTING WALL, FENCE, FOLIAGE,BERM, PARKED VEHICLES, SIGN OR OTHER OBJECTS BETWEEN THE HEIGHTS OF TWO (2)FEET AND EIGHT (8) FEET ABOVE THE CURB LINE ELEVATION, OR THE NEARESTTRAVELED WAY IF NO CURBING EXISTS, SHALL BE PLACED WITHIN A SIGHT TRIANGLE.12. WC ACCESS RAMPS WILL BE PROVIDED IN ACCORDANCE WITH RALEIGHENGINEERING STANDARD DRAWING T-20.01.2 & T-20.01.6.

Leith Auto Center Lot 2

Bldg Addition & Parking

Expansion

5603 Capital Boulevard

5800 Oak Forest Drive

PAVEMENT DESIGN NOTE:ALL PAVEMENT PROPOSED ON THIS PLAN IS TO BE8" ABC AND 3" S9.5B UNLESS OTHERWISE SPECIFIED.

SITE DATA

1726-28-5848

SITE ADDRESS: 5603 CAPITAL BLVD

& 5800 OAK FOREST ROAD

REQUIRED = 5 SPACES

PARKING CALCULATIONS FOR

PROPOSED WAREHOUSE & OFFICE ONLY

PARKING NOTE:

Since provided parking > 150% of required parking, interior

landscape islands and tree placements have been provided to

conform to sec. 7.1.2 D3.

9,632 sf @ 1 SP/3,000 sf = 4 SPACES

WAREHOUSE COMPONENT:

PROVIDED = 46 SPACES (Incl. 2 HC Spaces)

300 sf @ 1 SP/600 sf = 1 SPACES

WAREHOUSE COMPONENT:

Outdoor Amenity Calculations

10% of Site Area

Total Site Area = 14.03 Ac = 610,982 sf

Required Space = 1.40 Ac = 61,098 sf

Provided Space = 1.42 Ac = 61,737 sf

Build-To Calculations

50% of 399.53' (Site width at Oak Forest Drive)

Must have Building Facade (0'-100' from R/W)

Building Facade Required = 199.77'

Building Facade Provided = 200' (50.06%)

BICYCLE NOTE:

Bicycle spaces to be provided inside the warehouse building

REQUIRED = 4 LONG TERM

PROVIDED = 4 LONG TERM (SEE NOTE BELOW)

BICYCLE SPACES:

OPEN SPACE AMENITY

LOCATION KEY

SCALE 1" = 200'

Note:

All outdoor amenity areas are ADA

accessible via existing hardscape/walks

or by proposed concrete pads and

depressed curbs.

Page 8: LEITH AUTO CENTER BUILDING EXPANSION SR-16-2017 AUTO CENTER BUILDING EXPANSION ¯ SR-16-2017! ... AUTOMOBILE DEALERSHIP N/F ... These plans have been reviewed by the design engineer

CS-5

OWNER:

1" = 40'

(919) 876-5432

Raleigh, NC 27616

5601 Capital Blvd.

MLC Automotive, LLC

C-0329

Utility Plan

February 3, 2017

ALL CONSTRUCTION SHALL BE IN STRICT

ACCORDANCE WITH CURRENT CITY OF RALEIGH

AND/OR NCDOT STANDARDS AND SPECIFICATIONS.

UTILITY DATA:

STANDARD UTILITY NOTES (as applicable):

1. All materials & construction methods shall be in accordance with City of Raleigh design

standards, details & specifications (reference: CORPUD Handbook, current edition)

2. Utility separation requirements:

a) A distance of 100’ shall be maintained between sanitary sewer & any private or public

water supply source such as an impounded reservoir used as a source of drinking water. If

adequate lateral separation cannot be achieved, ferrous sanitary sewer pipe shall be

specified & installed to waterline specifications. However, the minimum separation shall

not be less than 25’ from a private well or 50’ from a public well

b) When installing water &/or sewer mains, the horizontal separation between utilities shall

be 10’. If this separation cannot be maintained due to existing conditions, the variation

allowed is the water main in a separate trench with the elevation of the water main at

least 18” above the top of the sewer & must be approved by the Public Utilities Director.

All distances are measured from outside diameter to outside diameter

c) Where it is impossible to obtain proper separation, or anytime a sanitary sewer passes

over a watermain, DIP materials or steel encasement extended 10’ on each side of

crossing must be specified & installed to waterline specifications

d) 5.0’ minimum horizontal separation is required between all sanitary sewer & storm sewer

facilities, unless DIP material is specified for sanitary sewer

e) Maintain 18” min. vertical separation at all watermain & RCP storm drain crossings;

maintain 24” min. vertical separation at all sanitary sewer & RCP storm drain crossings.

Where adequate separations cannot be achieved, specify DIP materials & a concrete

cradle having 6” min. clearance (per CORPUD details W-41 & S-49)

f) All other underground utilities shall cross water & sewer facilities with 18” min. vertical

separation required

3. Any necessary field revisions are subject to review & approval of an amended plan &/or profile by

the City of Raleigh Public Utilities Department prior to construction

4. Contractor shall maintain continuous water & sewer service to existing residences & businesses

throughout construction of project. Any necessary service interruptions shall be preceded by a 24

hour advance notice to the City of Raleigh Public Utilities Department

5. 3.0’ minimum cover is required on all water mains & sewer forcemains. 4.0’ minimum cover is

required on all reuse mains

6. It is the developer’s responsibility to abandon or remove existing water & sewer services not being

used in redevelopment of a site unless otherwise directed by the City of Raleigh Public Utilities

Department. This includes abandoning tap at main & removal of service from ROW or easement

per CORPUD Handbook procedure

7. Install 6" DIP water services with meters located at ROW or within a 2’x2’ Waterline

Easement immediately adjacent. NOTE: it is the applicant’s responsibility to properly size the

water service for each connection to provide adequate flow & pressure

8. Install 4" and 6” PVC sewer services @ 1.0% minimum grade with cleanouts located at ROW or

easement line & spaced every 75 linear feet maximum

9. Pressure reducing valves are required on all water services exceeding 80 psi; backwater valves are

required on all sanitary sewer services having building drains lower than 1.0’ above the next

upstream manhole

10. All environmental permits applicable to the project must be obtained from NCDWQ, USACE

&/or FEMA for any riparian buffer, wetland &/or floodplain impacts (respectively) prior to

construction.

11. NCDOT / Railroad Encroachment Agreements are required for any utility work (including main

extensions & service taps) within state or railroad ROW prior to construction

12. Grease Interceptor / Oil Water Separator sizing calculations & installation specifications shall be

approved by the CORPUD FOG Program Coordinator prior to issuance of a Building Permit.

Contact Tim Beasley at (919) 996-2334 or [email protected] for more information

13. Cross-connection control protection devices are required based on degree of health hazard

involved as listed in Appendix-B of the Rules Governing Public Water Systems in North Carolina.

These guidelines are the minimum requirements. The devices shall meet American Society of

Sanitary Engineering (ASSE) standards or be on the University of Southern California approval

list. The devices shall be installed and tested (both initial and periodic testing thereafter) in

accordance with the manufacturer’s recommendations or the local cross-connection control

program, whichever is more stringent. Contact Joanie Hartley at (919) 996-5923 or

1. [email protected] for more information

Leith Auto Center Lot 2

Bldg Addition & Parking

Expansion

5603 Capital Boulevard

5800 Oak Forest Drive

Page 9: LEITH AUTO CENTER BUILDING EXPANSION SR-16-2017 AUTO CENTER BUILDING EXPANSION ¯ SR-16-2017! ... AUTOMOBILE DEALERSHIP N/F ... These plans have been reviewed by the design engineer

CS - 7

OWNER:

1" = 40'

(919) 876-5432

Raleigh, NC 27616

5601 Capital Blvd.

MLC Automotive, LLC

C-0329

February 3, 2017

ALL CONSTRUCTION SHALL BE IN STRICT

ACCORDANCE WITH CURRENT CITY OF RALEIGH

AND/OR NCDOT STANDARDS AND SPECIFICATIONS.

Landscape Plan

= PROPOSED NAME OF PLANT & NUMBER OF PLANTS.

#

NAME

NOTE:

ALL DISTURBED AREAS OUTSIDE OF TCA'S

AND MULCH BEDS FOR PLANTING ARE TO BE GRASSED.

CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL LANDSCAPE

MATERIAL COUNTS SHOWN ON THESE PLANS.

Leith Auto Center Lot 2

Bldg Addition & Parking

Expansion

5603 Capital Boulevard

5800 Oak Forest Drive

Page 10: LEITH AUTO CENTER BUILDING EXPANSION SR-16-2017 AUTO CENTER BUILDING EXPANSION ¯ SR-16-2017! ... AUTOMOBILE DEALERSHIP N/F ... These plans have been reviewed by the design engineer

WHOLESALE PARTS STORAGE

COVERED CANOPY

54'-0

"

71'-8

5 8"

GENERAL STORAGE

200'-0"

136'-434"

1'-0

"

1'-0"

1'-0"658"

35'-838" 32'-6" 32'-6" 35'-83

8"1'-6"

29'-6" 29'-6"

1'-0"

658"

34'-0

"18

'-0"

17'-0

"

PROPOSED WALL LOCATION

These drawings are the property of Winstead Wilkinson Architects, PLLC. They may not be reused for any purpose without written permission. Copyright © 2017 by Winstead Wilkinson Architects, PLLC. All rights reserved.

1848 Wake Forest RoadRaleigh, NC 27608

t. 919-832-2878f. 919-832-7901

[email protected]

LEITH

WHO

LESA

LEPA

RTS

PROJECT NUMBER

DATE

REVISIONS

217102

FEBRUARY 2, 2017

New

Can

opy

for:

RALE

IGH,

NO

RTH

CA

ROLI

NA

A100

ELEVATIONS

1 REVISION 1 - 8/7/17

111

1FLOOR PLANSCALE: 1/8" = 1'-0"

2

2

2 REVISION 2 - 9/7/17

Page 11: LEITH AUTO CENTER BUILDING EXPANSION SR-16-2017 AUTO CENTER BUILDING EXPANSION ¯ SR-16-2017! ... AUTOMOBILE DEALERSHIP N/F ... These plans have been reviewed by the design engineer

CPEFIS

CMU

17'-7"

CB

EP-1

CB

EP-1 CMUCMU

EFISEFIS

CMU SF1SF1 SF1CMU 2 CMU 2 CMU 2

7'-0

"

LONGEST BLANK WALL 12.5'ELEVATION NOTES

BUILDING ELEVATION=3,045 SF (20% REQUIRED TRANSPARENCY)=609 SF PROVIDED 908 SF

12'-0

"

CMU

EFIS CP

EP-1

CB

12'-0

"

17'-7

"

CMU

EFISCP

EP-1

CB

These drawings are the property of Winstead Wilkinson Architects, PLLC. They may not be reused for any purpose without written permission. Copyright © 2017 by Winstead Wilkinson Architects, PLLC. All rights reserved.

1848 Wake Forest RoadRaleigh, NC 27608

t. 919-832-2878f. 919-832-7901

[email protected]

LEITH

WHO

LESA

LEPA

RTS

PROJECT NUMBER

DATE

REVISIONS

217102

FEBRUARY 2, 2017

New

Can

opy

for:

RALE

IGH,

NO

RTH

CA

ROLI

NA

2ELEVATIONSCALE: 1/8" = 1'-0"

1ELEVATIONSCALE: 1/8" = 1'-0"

3OAK FOREST ROAD ELEVATIONSCALE: 1/8" = 1'-0"

4ELEVATIONSCALE: 1/8" = 1'-0"

A101

ELEVATIONS

1 REVISION 1 - 8/7/17

111

2 REVISION 2 - 9/7/17

2

2