LED Qualification
description
Transcript of LED Qualification
LED Qualification
•Accepted Laboratories•Technical Criteria
•Examples
NVLAP Accredited • CA
– Bay Area Compliance Laboratories Corp., Sunnyvale, CA [200167- 0]
• GA– CSA INTERNATIONAL ENERGY EFFICIENT
LIGHTING PRODUCTS, Alpharetta, GA [200732- 0]Acuity Brands Lighting, Conyers Lab, Conyers, GA [200007- 0]
• IA– Musco Lighting Photometry Laboratory, Oskaloosa, IA
[200702- 0]
• KS– Philips Lighting Corporate Regulatory and Certification
Lab, Salina, KS [100399- 0]
• MA– OSRAM SYLVANIA, Metrology & Analytics Services,
Beverly, MA [100403- 0]
• MS– Daybrite Lighting (Philips) Photometric Laboratory,
Tupelo, MS [200016- 0]
• NY– Intertek, Cortland, NY [100402- 0]– Lighting Research Center Lighting Products, Troy, NY
[200480- 0]– Underwriters Laboratories, Inc., Melville, NY [100255- 0]
• OH– EYE Lighting International of North America, Inc.,
Mentor, OH [200783- 0]– GE Nela Park, Product Testing, Cleveland, OH [100398-
0]– Aurora International Testing Laboratory, Aurora, OH
[200571- 0]
• CHINA – Aurora International Testing Laboratory: Shanghai,
Shanghai, CHINA [200763- 0]– AUDIX Technology (Shenzhen) Co., Ltd., Shenzhen,
Guangdong 518057, CHINA [200372- 0]– Bay Area Compliance Laboratories Corp. (Shenzhen),
Shenzhen, Guangdong, CHINA [200707- 0]– Best Test Service (Shenzhen) Co., Ltd., Baoan
District , Shenzhen, 518133, CHINA [200770- 0]– Centre Testing International, Shanghai, 201206, CHINA
[200889- 0]– GECP Asia Technology Center Laboratory, Pudong
Area, Shanghai 201203, CHINA [200660- 0]– Intertek Testing Services Hangzhou Ltd., Hanzhou
310018, CHINA [200850- 0]– Intertek Testing Services Hong Kong Ltd., Hong Kong,
CHINA [200631- 0]– National Lighting Test Center (NLTC), Beijing, CHINA
[200720- 0]
• CHINA (P.R.C) – Lisheng Safety Laboratory, Xiamen, Fujian Province,
CHINA (P.R.C) [200882- 0]
• HUNGARY – GE Hungary KFT GE Lighting FL Technology
Photometry Laboratory, Budapest 1340, HUNGARY [200651- 0]
Comparison
LM-79 Results• 57 lm/W• CBCP : 4167 cd• CRI : 80.2• Warranty : 3 yr• CCT : 3691 K• Power factor : 0.521• Life Rated 30,000+ hr
Minimum Requirements• 45 lm/W• CBCP : 590 cd• CRI : 80• Warranty : 3 yr• CCT : 3500 + 245 K• Power Factor : 0.70• Life Rated : 25,000 hr
Conclusion • The LED lamps Meet:
– Efficacy– Minimum Light Output – CRI– Manufacture Warranty– CCT– Lumen Maintenance– Power Factor
• This LED lamp is not eligible for an incentive.
Example of an eligible LED Par 38
Comparison
LM-79 Results• 50.42 lm/W• CBCP : 4509 cd• CRI : 87.4• Warranty : 3 yr• CCT : 3083 K• Power factor : 0.776• Life Rated 30,000+ hr
Minimum Requirements• 45 lm/W• CBCP : 590 cd• CRI : 80• Warranty : 3 yr• CCT : 3045 + 175 K• Power Factor : 0.70• Life Rated : 25,000 hr
This LED light is eligible