LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good...
Transcript of LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good...
![Page 1: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/1.jpg)
LED Lamp Investigation
by
Peter & Sharon Metcalfe
![Page 2: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/2.jpg)
The lamp that started it all! Most manufacturers deny a breach
of the regulations this one appears
to advertise it.
“We are now offering our most
popular light fitted with the latest
LED technology. Only uses 5w of
energy.
This LED model will
interfere with DAB
broadcasts.”
![Page 3: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/3.jpg)
Technical note:
The keen eyed amongst you will note that many of the following
emission sweeps reference EN55022.
While this is technically incorrect (EN55015 references EN55011), for
investigative work this has absolutely no bearing on the validity of the
results found.
EN55011 Group 1 Class B and EN55022 Class B are, to all intents and
purposes, identical.
![Page 4: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/4.jpg)
HALOGEN bulb fitted to floor standing lamp unit (mains powered)
Radiated Emissions
Worst case margin is >12dB below Class B limit.
These emissions were subsequently traced to the 12V smps.
![Page 5: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/5.jpg)
LED bulb1 fitted (Opti-led 3.5W) Radiated Emissions
Worst case margin is 15.78dB ABOVE Class B limit
![Page 6: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/6.jpg)
LED bulb 2 fitted (Philips 7W) Radiated Emissions
Worst case margin is 7.11dB ABOVE Class B limit
![Page 7: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/7.jpg)
As a quick comparison, the following Radiated Emissions traces show:- Halogen bulb (Red line) LED 1 Opti-led 3.5W (Cyan line) LED 2 Philips 7W (Dark Blue line)
![Page 8: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/8.jpg)
HALOGEN bulb fitted to floor standing lamp unit (mains powered)
Conducted Emissions
Average detector 9.51dB ABOVE Class B limits
Q-P detector 8.54dB ABOVE Class B limits
![Page 9: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/9.jpg)
LED bulb1 fitted (Opti-led 3.5W) Conducted Emissions
Average detector 12.71dB ABOVE Class B limits
Q-P detector 7.57dB ABOVE Class B limits
![Page 10: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/10.jpg)
LED bulb 2 fitted (Philips 7W) Conducted Emissions
Average detector 15.69dB ABOVE Class B limits
Q-P detector 15.12dB ABOVE Class B limits
![Page 11: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/11.jpg)
Conducted emissions:- Halogen bulb (Red line) LED 1 Opti-led 3.5W (Cyan line) LED 2 Philips 7W (Dark Blue line)
The lower frequency emissions were attributed to the smps, but note the
large variation between bulb types around 10MHz
![Page 12: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/12.jpg)
Other LED lighting units (battery powered)
e.g.
All gave “noise floor” emission results
![Page 13: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/13.jpg)
BULB only investigations
(linear 12V psu, 30cm twisted pair)
![Page 14: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/14.jpg)
Radiated emissions:- Halogen (Red line) LED 1 Opti-led 3.5W (Cyan line) LED 2 Philips (Dark Blue line)
![Page 15: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/15.jpg)
Components!
![Page 16: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/16.jpg)
In pieces LED plate only (AC/DC unit removed)
Radiated emissions
As expected – noise floor emissions
![Page 17: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/17.jpg)
Bulb only Conducted Emissions measurement
on DC input to bulb (12VDC supplied via LISN)
LED bulb 1: Opti-led 3.5W
Average detector 30.83dB ABOVE Class B limits
Q-P detector 20.30dB ABOVE Class B limits
![Page 18: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/18.jpg)
Bulb only Conducted Emissions measurement
on DC input to bulb (12VDC supplied via LISN)
LED bulb 2: Philips 7W
Average detector 57.74dB ABOVE Class B limits
Q-P detector 61.64dB ABOVE Class B limits Note: “Overload” detected during readings so linearity not guaranteed.
![Page 19: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/19.jpg)
12V ac/dc
Deltech 4W MR16 12V
AC/DC (30W Halogen
equiv)
More Lamps
Conducted Emissions
Radiated Emissions
![Page 20: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/20.jpg)
240V ac Lamps
GE 1W (28 lumen) White GU10
230-240V
Conducted Emissions
Radiated Emissions
![Page 21: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/21.jpg)
240V ac Lamps
GE 4W (225 candela) White
GU10 240V
Conducted Emissions
Radiated Emissions
![Page 22: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/22.jpg)
240V ac Lamps
Alpha 1.3W (8W incandescent
equiv) GU10 240V
Conducted Emissions
Radiated Emissions
![Page 23: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/23.jpg)
MR11 LED Bulb Conducted Emissions
Measured Measured Measured Measured Q-P
Marker Frequency (MHz) Peak (dBuV) Average (dBuV) Q-P (dBuV) Limit (dBuV)
2 0.35289 71.41 * 53.67 69.09 * 58.90
1 1.4523 74.13 * 57.98 * 73.48 * 56.00
Q-P readings are greater than 17dB ABOVE Class B limit FAIL
![Page 24: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/24.jpg)
MR11 LED Bulb Radiated Emissions
![Page 25: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/25.jpg)
18W 1200mm 230V Strip Light Conducted Emissions
This unit FAILS the conducted (Q-P) requirement by 7.37dB (marker #1)
Measured Measured Measured
Marker Frequency (MHz) Peak (dBuV) Average (dBuV) Q-P Limit (dBuV)
6 3.5158 61.48 * 55.93 56.00
4 3.8827 61.08 * 58.02 * 56.00
1 4.0892 65.19 * 63.37 * 56.00
2 H 4.1091 64.20 * 59.21 * 56.00
5 4.3906 57.77 * 53.02 56.00
3 4.6209 60.80 * 55.52 56.00
9-150kHz conducted and also 30-300MHz radiated emissions are all well within requirements
![Page 26: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/26.jpg)
Tim Williams has been carrying out independent
investigations on 240V ac lamps and has found all to be
compliant for conducted emissions, but have quite different
characteristics especially below 150kHz.
We, along with Keith Armstrong, are concerned that we may
have a “misunderstanding of the EMC Standards and
Regulations” as lamp manufacturers appear to be under the
misapprehension that only conducted emissions testing is
required and then only for 230/240V units.
![Page 27: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/27.jpg)
The ‘problem’ may be wider than initially
thought The following was discovered by Terry Wells (Virgin Media)
Reported to us via Brian Copsey
Question re: LED Interference with VHF
“I recently installed an LED tri-color and an LED anchor light.
Unfortunately, now whenever I have either light on I only hear
static on all stations on my VHF, no matter what I do with the
squelch. Its no good because its important that I have the tri-
color and the VHF working properly at the same time for night
sailing. Any suggestions as to what is causing this”?
![Page 28: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/28.jpg)
We were recently informed by a company, who install
studio equipment, that many professional recording
studios have banned the use of “energy efficient”
lighting, in particular LED lighting!
Dave Bowman of Quantel is “looking into this”!
![Page 29: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/29.jpg)
Summary: The Good
•The LEDs themselves are, as expected, benign and do not emit.
•Available 240V units appear to be compliant (at least above 150kHz).
•If 240V lamps do employ switching circuitry then the technology
and/or filtering used appears to be adequate for compliance.
•Low voltage units employing LEDs only (torches, panel indicators,
etc.) are no problem.
•Even some low voltage units employing switching circuitry are no
problem.
![Page 30: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/30.jpg)
Summary: The Bad
• Some low voltage LED units employing electronic devices (constant
current sourcing?) exhibit unacceptable conducted emissions.
• Problems are beginning to emerge in areas other than domestic
lighting.
• The current trend towards “energy efficient” lighting means that LED
usage will become much more widespread.
• These units are often installed as part of a low voltage distribution
system which could extend over an entire building.
• Reports seem to show that the lighting industry does not appreciate
the need for low voltage device emissions testing.
• Research into better ac/dc converters and constant current devices,
along with adequate filtering, is essential.
![Page 31: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/31.jpg)
Each household will have, at worst, only one PLT device
But with results such as these:-
What will be the impact on the power distribution network when
you consider how many LED lights a household may have?
Summary: The Ugly
![Page 32: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/32.jpg)
And this is where our investigation might have stopped.
Indeed, we were demonstrating these findings at the
EMCUK trade show in October when we suddenly found
one of our lamps, which previously was thought to have
few emissions, suddenly went way above the limit!
Tracing the problem we noticed that the voltage supply to
the bulb had drifted off 12V.
This led us to a whole new line of investigation and by now
other people, including Keith Armstrong, had lent us more
LED bulbs to look at.
![Page 33: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/33.jpg)
Unbranded LED MT16 6W Radiated Emissions with the voltage set to exactly 11V
Radiated emissions are well under the limit line.
![Page 34: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/34.jpg)
Unbranded LED MT16 6W Radiated Emissions with the voltage set to exactly 12V
No radiated emissions problems at exactly 12V
![Page 35: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/35.jpg)
Unbranded LED MT16 6W Radiated Emissions with the voltage set to exactly 13V
Radiated emissions “slightly” above the limit line!
![Page 36: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/36.jpg)
Unbranded LED MT16 6W Radiated Emissions 11V with comparison overlays for
voltages at 12V and 13V
Traces: Dark blue 11V Cyan 12V Red 13V
![Page 37: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/37.jpg)
Unbranded LED MT16 6W Conducted Emissions with the voltage set to exactly 11V
No conducted emissions problems at exactly 11V
![Page 38: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/38.jpg)
Unbranded LED MT16 6W Conducted Emissions with the voltage set to exactly 12V
No problems
![Page 39: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/39.jpg)
Unbranded LED MT16 6W Conducted Emissions with the voltage set to exactly 13V
Not quite noise floor!
![Page 40: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/40.jpg)
Unbranded LED MT16 6W Conducted Emissions 11V with comparison overlays for voltages 12V and13V
Traces: Dark blue 11V Cyan 12V Red 13V
![Page 41: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/41.jpg)
Some are poor at all voltages!
Not all LED bulbs exhibit this poor behaviour.
![Page 42: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/42.jpg)
Unbranded 12V/AC DC bulb Radiated Emissions with comparison voltages
Traces: Dark blue 11V Cyan 12V Red 13V
![Page 43: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/43.jpg)
Unbranded 12V/AC DC bulb Conducted Emissions with comparison voltages
Traces: Dark blue 11V Cyan 12V Red 13V
![Page 44: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/44.jpg)
Deltech MR16 5W bulb Radiated Emissions with comparison voltages
Traces: Dark blue 11V Cyan 12V Red 13V
![Page 45: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/45.jpg)
Deltech MR16 5W bulb Conducted Emissions with comparison voltages
Traces: Dark blue 11V Cyan 12V Red 13V
Traces: Dark blue 11V Cyan 12V Red 13V
The frequency where problems occur changes as the supply voltage changes.
![Page 46: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/46.jpg)
LED bulb 2: Philips 7W Radiated Emissions with comparison voltages
Traces: Dark blue 11V Cyan 12V Red 13V
![Page 47: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/47.jpg)
LED bulb 2: Philips 7W Conducted Emissions with comparison voltages
Traces: Dark blue 11V Cyan 12V Red 13V
Traces: Dark blue 11V Cyan 12V Red 13V
![Page 48: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/48.jpg)
The critical voltage isn’t always the same!
![Page 49: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/49.jpg)
LED 3: Unbranded MR16 4W Radiated Emissions with comparison voltages
Traces: Dark blue 11V Cyan 12V Red 13V
![Page 50: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/50.jpg)
LED 1: Unbranded MT16 6W Radiated Emissions 11V with comparison overlays for
voltages at 12V and 13V
Traces: Dark blue 11V Cyan 12V Red 13V
![Page 51: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/51.jpg)
Does using AC voltages make a difference?
![Page 52: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/52.jpg)
Unbranded LED MT16 6W Conducted Emissions with the voltage set to exactly 9V
Radiated emissions are also well under the limit line.
![Page 53: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/53.jpg)
Unbranded LED MT16 6W Conducted Emissions with the voltage set to exactly 10V
![Page 54: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/54.jpg)
Unbranded LED MT16 6W Conducted Emissions with the voltage set to exactly 15V
![Page 55: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/55.jpg)
Unbranded LED MT16 6W Conducted Emissions with the comparison voltages 9V, 10V, 15V
Traces: Red 9V Cyan 10V Dark blue 15V
![Page 56: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/56.jpg)
LED 2: Philips 7W Conducted Emissions 2V AC (Lamp just on)
![Page 57: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/57.jpg)
LED 2: Philips 7W Conducted Emissions 12V AC (rated voltage)
![Page 58: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/58.jpg)
LED 2: Philips 7W Conducted Emissions 15V AC (rated voltage)
![Page 59: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/59.jpg)
LED 2: Philips 7W Conducted Emissions 15V AC with comparison overlays
Traces: Red 2V Cyan 12V Dark blue 15V
![Page 60: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/60.jpg)
LED 3: Unbranded MT16 4W Conducted Emissions 8V AC
![Page 61: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/61.jpg)
LED 3: Unbranded MT16 4W Conducted Emissions 9V AC
![Page 62: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/62.jpg)
LED 3: Unbranded MT16 4W Conducted Emissions 15V AC
![Page 63: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/63.jpg)
LED 3: Unbranded MT16 4W Conducted Emissions 15V AC with comparison overlays
Traces: Red 8V Cyan 9V Dark blue 15V
![Page 64: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/64.jpg)
Keith Armstrong’s bulb (Philips 4W) Conducted Emissions 8V AC
![Page 65: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/65.jpg)
Keith Armstrong’s bulb (Philips 4W) Conducted Emissions 9V AC
![Page 66: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/66.jpg)
Keith Armstrong’s bulb (Philips 4W) Conducted Emissions 12V AC
![Page 67: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/67.jpg)
Keith Armstrong’s bulb (Philips 4W) Conducted Emissions 15V AC
![Page 68: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/68.jpg)
Keith Armstrong’s bulb (Philips 4W) Conducted Emissions 15V AC with overlays
Traces: Black (noise floor) 8V Red 9V Cyan 12V Dark blue 15V
![Page 69: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/69.jpg)
The order of enquiries made by an EMC complainant with each group suggesting the next one.
• Hursley “We were recently at a presentation by Peter Metcalfe on just this topic. Try …”
• Ofcom: “Not our pigeon. Try…”
• British Standards Institute (who first suggested Trading Standards): “Why not try …”
• UKAS: “Why us? Try…”
• Nemko Ltd: “You need an expert. Try…”
Timeline of an EMC Complaint Comments paraphrased from phone conversations with an LED complainant
• Which? The consumer association: “Come back when you have a story”
• Consumer Direct: “Sorry. Not our area of expertise. Try…”
• METECC: We carried out investigative work followed by extensive discussion
which resulted in the following …
• TUV: “We’re a test house. We don’t investigate complaints why not try…”
![Page 70: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/70.jpg)
The follow-up:
• Trading Standards (Devon): “Said they were under no obligation to contact me back.
They also said that they do not take complaints from consumers, who should contact
Consumer Direct. The Consumer Direct website says how to complain to a company but
not how to complain about a company”
• Ofcom (again): Received the infamous quote
“Interference issues that affect broadcast transmissions are not our responsibility.
This is now the responsibility of the BBC”
• Which?: “They are well behind with answering queries so ...”
•Given that all the original complaint started on 19th August, my
complainant is beginning to feel that no one in authority is really
bothered.
Timeline of an EMC Complaint Comments paraphrased from phone conversations with an LED complainant
• Consumer Direct: “Said they had logged the call and passed it to Trading Standards”
• BBC: “BBC Reception Helpdesk tells me that they passed my concerns to the BBC
Distribution Team (whatever that is) who will get back to me. But they have no timescale to do so.
![Page 71: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/71.jpg)
Subsequent to the original presentation of this
piece, METECC have been informed of the following
official OFCOM/BBC position:-
“OFCOM have passed over all responsibility for
investigation of radio interference matters to the
BBC but have retained all aspects for prosecution”.
![Page 72: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/72.jpg)
•One body has the remit to investigate but not prosecute
What a pity the two bodies do not give the
impression that they are talking to each other!
•One body has the remit to prosecute but not investigate
So – the situation is that:-
![Page 73: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/73.jpg)
You may think that this is a joke
But that is exactly what has been happening.
![Page 74: LED Lamp Investigation by Peter & Sharon Metcalfe - EMCIA Investigation.pdf · Summary: The Good •The LEDs themselves are, as expected, benign and do not emit. •Available 240V](https://reader034.fdocuments.us/reader034/viewer/2022042921/5f688ea9df2d4b68fc10f393/html5/thumbnails/74.jpg)
Please feel free to contact us to discuss this further.
Thank you for your attention
Peter Metcalfe [email protected] Tel: 07725 079956 Sharon Metcalfe [email protected] Tel: 07525 812524 METECC www.metecc.eu