LDAU Leakage Data Acquisition Unit Patents No. US7467545, AU2008249554.
-
Upload
chester-richardson -
Category
Documents
-
view
212 -
download
0
Transcript of LDAU Leakage Data Acquisition Unit Patents No. US7467545, AU2008249554.
![Page 1: LDAU Leakage Data Acquisition Unit Patents No. US7467545, AU2008249554.](https://reader035.fdocuments.us/reader035/viewer/2022081603/56649e7b5503460f94b7c96d/html5/thumbnails/1.jpg)
LDAULDAULeakage Data Acquisition UnitLeakage Data Acquisition UnitPatents No. US7467545, AU2008249554Patents No. US7467545, AU2008249554
![Page 2: LDAU Leakage Data Acquisition Unit Patents No. US7467545, AU2008249554.](https://reader035.fdocuments.us/reader035/viewer/2022081603/56649e7b5503460f94b7c96d/html5/thumbnails/2.jpg)
The problemThe problemLoss of water due to leaky mains pipes
Reasons:1) Old and poorly constructed pipelines.2) Inadequate corrosion protection.3) Poorly maintained valves.4) Mechanical damage.5) Amplification of pressure.
![Page 3: LDAU Leakage Data Acquisition Unit Patents No. US7467545, AU2008249554.](https://reader035.fdocuments.us/reader035/viewer/2022081603/56649e7b5503460f94b7c96d/html5/thumbnails/3.jpg)
Water loss informationWater loss information
Examples of water loss worldwide :
1) London – 1000 million liters per day (nearly 50%).(Enough to fill 17 Olympic sized swimming pools every hour)2) New York City - nearly 15% loss3) Boston – nearly 36% loss4) Mexico City – nearly 32% loss5) Montreal - nearly 40% loss6) Seoul – nearly 35% loss7) Ukraine cities – nearly 30% loss8) Vietnam cities – nearly 50% loss
![Page 4: LDAU Leakage Data Acquisition Unit Patents No. US7467545, AU2008249554.](https://reader035.fdocuments.us/reader035/viewer/2022081603/56649e7b5503460f94b7c96d/html5/thumbnails/4.jpg)
The solution - LDAUThe solution - LDAUThe LDAU is a light weight and cost effective LeakageData Acquisition Unit developed using the ExorBluepatented technology for current measurements.
The LDAU provides with a simple and quality assured, theassessing aspects of the leakages locations in water pipes.
![Page 5: LDAU Leakage Data Acquisition Unit Patents No. US7467545, AU2008249554.](https://reader035.fdocuments.us/reader035/viewer/2022081603/56649e7b5503460f94b7c96d/html5/thumbnails/5.jpg)
Operation – Step 1Operation – Step 1
Transferring the LDAU through the water pipeTransferring the LDAU through the water pipe
![Page 6: LDAU Leakage Data Acquisition Unit Patents No. US7467545, AU2008249554.](https://reader035.fdocuments.us/reader035/viewer/2022081603/56649e7b5503460f94b7c96d/html5/thumbnails/6.jpg)
Operation – Step 2Operation – Step 2Transmission of the data to Transmission of the data to laptop/smartphone/server via WIFI protocollaptop/smartphone/server via WIFI protocol
![Page 7: LDAU Leakage Data Acquisition Unit Patents No. US7467545, AU2008249554.](https://reader035.fdocuments.us/reader035/viewer/2022081603/56649e7b5503460f94b7c96d/html5/thumbnails/7.jpg)
Operation – Step 3Operation – Step 3Data Analyzing using the water currents and Data Analyzing using the water currents and temperatures parameters in real timetemperatures parameters in real time
![Page 8: LDAU Leakage Data Acquisition Unit Patents No. US7467545, AU2008249554.](https://reader035.fdocuments.us/reader035/viewer/2022081603/56649e7b5503460f94b7c96d/html5/thumbnails/8.jpg)
Technical InfoTechnical InfoTYPE: EXOR BLUE PATENTED TECHNOLOGY – LDAU
Sensor SIZE: 3mm – (optional 1.5mm)LDAU Size: 150mm x 60mm x 60mm
WEIGHT: 400 grams
Currents Range: 0 to 2 [m/s], (0 to 4 knots)
ACCURACY: +- 0.01[m/s] -> below 0.2[m/s] +- 0.05[m/s] -> above 0.2[m/s] +- 0.1[m/s] -> above 1[m/s]
COMMUNICATION: WIFI protocol
DATA SAVING PING RATE: 1/second ( every 1 second new data )
Power: 4 AA alkaline batteries provides minimum of 50 hours continuous use.The batteries can be replaced by the user.
TEMPERATURE RANGE: 0-37° C