Latex and Silicone Brochure
-
Upload
elisabeth-brown -
Category
Documents
-
view
15 -
download
1
Transcript of Latex and Silicone Brochure
Choices matter
Advancing Lives and the Delivery of Healthcare.®
Insertion
Maintenance
Duration
Utilization
FOLEY CATHETERS
LATEX AND SILICONE
MAKING STRIDES TO PREVENT AND DOCUMENT HAIS
Government intervnetion timeline
CDC guidelines
DeficitReduction
Act
CDCGuidelineUpdate
AffordableCare Act
HospitalAcquiredConditionReductionProgram
2006 2009 2010 2014
OUR RESPONSE: ADJUSTING OUR STANDARDS FOR CAUTI PREVENTION
UTILIZATION:
INSERTION:
MAINTENANCE:
Orange stickersheet, othersheets in theFoley tray
Indications onpackaging, fullrange Foley alternatives
Gloves, handsanitizer
Perineal wipe,iodine sticks, applicatorenhancements,stepwiseinsertion tray
Safety seal, statlock, closed system trays,statlock in tray, dailey foley care, temperevident seal
WHAT ABOUT THE FOLEY?Accessory connectingtube
Accessory meter bag
Class II Invasive Foleycatheter
Barrier seal
1.5 times more painful to remove a siliconeFoley catheter than latex
Occurred more frequently than symptomaticUTIS with 32% of these cases leadingto medical intervention
Leads to the development of bacteriaknown to exist in biofilm and causeCAUTIs
FOCUSING ON THE FOLEY: THE MECHANICAL CONSEQUENCES
PAINFULREMOVAL
CATHETER-RELATEDPAIN
BLADDERINFLAMMATION
Latex Foley Catheter
COMPONENTS OF THE FOLEY:
Smooth tip Wide eyelet
Compatible composition
Effective drainage funnel & accesible inflation port
Secure balloon design
Coated inner lumen
Bonding-friendly surface
Silicone Foley Catheter
MATERIAL MAKES ALL THE DIFFERENCE
Structured material
100% siliconeSi14
Silicone28.0855
Bardex® I.C. Anti-Infective Foley catheter:Indications for Use:
• Patient has acute urinary retention or bladder outlet obstruction• Need for accurate urine output measurements• Use for selected surgical procedures• To assist in healing of open sacral or perineal wounds• Patient requires prolonged immobilization• To improve comfort for end of life care
Cautions:• The Bardex® Foley catheter and Bardex® I.C. anti-infective Foley
catheter contain natural rubber latex which may cause allergic reactions.
• Federal (U.S.A.) law restricts these devices to sale by or on the order of a physician.
Warnings:• On catheter, do not use ointments or lubricants having a
petrolatum base. They will damage the catheter and may cause balloon to burst.
• After use, this product may be a potential biohazard. Handle and dispose of in accordance with accepted medical practices and applicable local, state and federal laws and regulations.
Bard and Bardex are registered trademarks of C.R. Bard, Inc. Bactiguard®* is a registered trademark of BactiGuard AB.*The Foley catheters included in the Bardex® I.C. System contain Bactiguard®* silver alloy coating whichis licensed from BactiGuard AB. 2016 C. R. Bard, Inc. All Rights Reserved. 1606-38 R05/16 BMD/XXXX/0716/XXXX
C. R. Bard, Inc.Covington, GA 30014800.526.4455bardmedical.com
Available for silicone and latex Foley cathetersPERMANENT COATINGS
STANDARD:
ADVANCED:
PREMIUM:
Engineered to minimize tissue trauma dur-ing insertion and removal of catheter
Designed to absorb mucosal fluid and form a “cushioned” bar-rier around the catheter, preventing bacterial adherence and en-crustation, and improve comfort.
Designed to allow “communication” be-tween hydrogel and noble metal ions on the surface of the catheter, resulting in a well-lubricated anti-infective catheter exte-rior.
Silicone Exterior
Lubricious Hydrogel Finish
Hydrogel and Bactiguard® Finish