lagoon® Advanced Care · Wool filling factor 1:15 kg Silk filling factor 1:18 kg Drum, volume...

7
PROFESSIONAL LAUNDRY lagoon® Advanced Care WH6-20LAC and TD6-20LAC The ideal replacement for any dry-cleaning operation Features and benefits Keep customers coming back Outstanding results for garments of every type thanks to specialized detergents and dedicated programs Delicate on the delicates Gentle on fine textiles and wools labelled dry-clean only, as less mechanical action. Woolmark-approved Rapid return on investment With a better loading factor, less prespotting, easier finishing and faster pro- cess times Sustainable and eco-friendly Water-based cleaning with none of the disadvantages of PERC, which can be dangerous to staff Dry to dry in 1 hour Smart chemicals and processes mean garments are fully dried in the dryer - no hang-dry

Transcript of lagoon® Advanced Care · Wool filling factor 1:15 kg Silk filling factor 1:18 kg Drum, volume...

Page 1: lagoon® Advanced Care · Wool filling factor 1:15 kg Silk filling factor 1:18 kg Drum, volume litre diameter ø mm Extractionrpm G-factor Heating alternative electricity kW ... Professional

PROFESSIONAL LAUNDRY

lagoon® Advanced CareWH6-20LAC and TD6-20LAC

The ideal replacement for any dry-cleaning operation

Features and benefitsKeep customers coming backOutstanding results for garments of every type thanks to specialized detergents and dedicated programs

Delicate on the delicatesGentle on fine textiles and wools labelled dry-clean only, as less mechanical action. Woolmark-approved

Rapid return on investmentWith a better loading factor, less prespotting, easier finishing and faster pro-cess times

Sustainable and eco-friendlyWater-based cleaning with none of the disadvantages of PERC, which can be dangerous to staff

Dry to dry in 1 hourSmart chemicals and processes mean garments are fully dried in the dryer - no hang-dry

Page 2: lagoon® Advanced Care · Wool filling factor 1:15 kg Silk filling factor 1:18 kg Drum, volume litre diameter ø mm Extractionrpm G-factor Heating alternative electricity kW ... Professional

WH6-20LAC

20 14 10 180 725 1055 450 18.0

22 23 16 20 17 20

110 106 80 85 80 95

0.15/1.0 0.15/1.0 0.05/0.6 0.15/1.0 0.05/0.95 0.05/0.7

65 113+10 0.5/2.2/0.55 45

TD6-20LAC

20360 755 18.021.025.0 6.5

19 18 16 24 16 15 14 21 12 12 10 29

27 26 23 44 8.2 9.3 9.9 2.99 302 321 352 185 1.00 1.13 1.21 0.36

Main specificationsMax. capacity Laundry filling factor 1:9 kg

Wool filling factor 1:15 kg Silk filling factor 1:18 kg

Drum, volume litre diameter ø mm

Extraction rpm G-factorHeating alternative electricity kWConsumption data ”lagoon” Total time Wool High min

Wool Medium min Silk min Synth. mix Medium min Synth. mix Low min Curtains min

Water consumption (cold+hot) Wool High litre Wool Medium litre Silk litre Synth. mix Medium litre Synth. mix Low litre Curtains litre

Energy consumption (motor/heating/water) Wool High kWh Wool Medium kWh Silk kWh Synth. mix Medium kWh Synth. mix Low kWh Curtains kWh

Consumption data ECO 60 1:9* Total time min Water consumption (cold+hot) litre Energy consumption (motor/heating/hot water) kWh Residual moisture % * Water temperature 15°C cold water and 65°C hot water.

* 1:30 load 100% wool load at 30% initial moisture dryed to 0%.** 1:40 load 100% synthetic load at 20% initial moisture dryed to 0%.*** At rated capacity 100% cotton load at 50% initial moisture dryed to 0%.

Main specificationsMax. capacity Drying filling factor 1:18 kgDrum, volume litre

diameter ø mm Heating alternative electricity kW

gas BTU/h (kW) steam at 700 kPa heat pump kW

Consumption data ”lagoon”

Total time Wool High* min Wool Medium* min Synthetic mix** min

Consumption data***

Total time min Energy consumption (motor/heating/hot water) kWh Evaporation g/min Energy/Water evaporation kWh/l

El Gas Steam Heat pump

Page 3: lagoon® Advanced Care · Wool filling factor 1:15 kg Silk filling factor 1:18 kg Drum, volume litre diameter ø mm Extractionrpm G-factor Heating alternative electricity kW ... Professional

WH6-20LAC

20 200-600

307517015

300-6005

17.6 4.2 ± 1.0

84/68 66/50

5

354 1.66

x x x

970 947 1412 461 526 1511 1130 150 1329 402 302 1288 1208 348 100 333 342 217

220-240V 3 ~ 50/60 18.0 18.5 50 380-415V 3N/3 ~ 50/60 18.0 18.5 35 440V 3 ~ 60 18.0 18.5 25 480V 3 ~ 60 18.0 18.5 25

220-480V 1 ~ 50/60 - 2.5 10

A

C

3

1

2

B

E

D2D1

IJG

74

N

H

LK

10

11

F

8M O

9

5 Q6

P

Rear

Side view

Front

Electrical connections Heating Main voltage Heating Total Recommended alternative power power fuse

Hz kW kW A

Electric heated

Steam or Non heated

* Total power and recommended fuse does not depend on the heating power in those cases.

Water and steam connection

Water valves DN Water pressure kPa Capacity at 300 kPa l/min Drain valve ø mm Draining capacity l/min Steam valve DN Steam pressure kPa Liquid detergent supplies

Floor requirements

Frequency of the dynamic force Hz Floor load at max extraction kN

Sound levels

Sound power/pressure level at extraction* dB(A) Sound power/pressure level at wash* dB(A)

Heat emission

% of installed power, max

Shipping data**

Weight net, kg Shipping volume m3

Accessories

Steel base Hose kits for water or steam Fluff collector

Dimensions in mm

A Width B Depth C Height D1 D2 E F G H I J K L M N O P Q

1 Display 2 Door opening ø 435 mm 3 Detergent box 4 Cold water 5 Hot water 6 Cold/Hot water

7 Re-used water 8 Drain valve

9 Liquid detergent supply 10 Electrical connection 11 Steam connection

* Sound power levels measured according to ISO 60704.** Average data. Crated weight/shipping volume depends on configuration.

Please contact logistics for exact measures.

Page 4: lagoon® Advanced Care · Wool filling factor 1:15 kg Silk filling factor 1:18 kg Drum, volume litre diameter ø mm Extractionrpm G-factor Heating alternative electricity kW ... Professional

220-230V 3 ~ 50/60 18.0 19.0 50 240V 3 ~ 50/60 18.0 19.0 50 380-415V 3N ~ 50/60 18.0 19.0 35 440V 3 ~ 50/60 18.0 19.0 35 480V 3 ~ 60 18.0 19.0 25

220-240V 3 ~ 50/60 * 1.0 10 380-415V 3N ~ 50/60 * 1.0 10

440V 3 ~ 50/60 * 1.0 10 480V 3 ~ 60 * 1.0 10

TD6-20LAC

1” 100-1000

65 1”

1/2”

2000 20

2800-5000 28-50 200 525 600 690 650 650 650

72/56

15

243 2.07

790 1202 1342 1771 773 836 750 110 62 270 240 174 605 739 396

1

2

A

C

I

3

J

K

G

H

4

5

7

N

3

L

M

6

J

K

5

B(a) D

EF

B(b)

Front

Left side

Electrical connections Heating Main voltage Heating Total Recommended alternative power power fuse

Hz kW kW A

Electric heated

Gas heated/ Steam heated

Rear side

El, gas Steam

* Total power and recommended fuse does not depend on the heating power in those cases.

* Sound power levels measured according to ISO 60704.** Average data. Crated weight/shipping volume depends on configuration.

Please contact logistics for exact measures.

Steam, gas and air connections

Steam ISO 7/1-R Steam pressure kPa Steam consumption kg/h Condensate ISO 7/1-R Gas ISO 7/1-R Gas pressure

Natural gas Pa mbar

Propane Pa mbar

Air outlet ø mm Evacuated air, el 18.0 kW m3/h

gas 21.0 kW steam 25.0 kW

Pressure drop el 18.0 kW Max. Pa gas 21.0 kW steam 25.0 kW

Sound levels

Sound power/pressure level at drying* dB(A)

Heat emission

% of installed power, max

Shipping data**

Weight kg Shipping volume crated, m3

Dimensions in mm

A Width B(a) Depth, el and gas B(b) Depth, steam C HeightD E F G H I JK L M N

1 Operating panel 2 Door opening ø 580 mm 3 Electrical connection on gas heated machines 4 Gas connection/Electrical connection on electrical heated machines5 Exhaust connection6 Condensate connection7 Steam connection

Page 5: lagoon® Advanced Care · Wool filling factor 1:15 kg Silk filling factor 1:18 kg Drum, volume litre diameter ø mm Extractionrpm G-factor Heating alternative electricity kW ... Professional

220-240V 1/1N ~ 50/60 * 5.5 25 380-415V 3/3N ~ 50/60 * 6.5 10

TD6-20LAC

72/56

15

308 2.15

790 1202 1229 1771 773 836 750 110 270 123 262

D

EF

B(a)

B(b)

1

2

A

C

J

4

G

H

3

I

Electrical connections Heating Main voltage Heating Total Recommended alternative power power fuse

Hz kW kW A

Heat pump

* Total power and recommended fuse does not depend on the heating power in those cases.

* Sound power levels measured according to ISO 60704.** Average data. Crated weight/shipping volume depends on configuration.

Please contact logistics for exact measures.

Sound levels

Sound power/pressure level at drying* dB(A)

Heat emission

% of installed power, max

Shipping data**

Weight kg Shipping volume crated, m3

Dimensions in mm

A(a) Width B(a) Depth B(b) Depth C HeightD E F G H I J

1 Operating panel 2 Door opening ø 580 mm 3 Electrical connection 4 Drain for condense water

Front

Left side

Rear side

Page 6: lagoon® Advanced Care · Wool filling factor 1:15 kg Silk filling factor 1:18 kg Drum, volume litre diameter ø mm Extractionrpm G-factor Heating alternative electricity kW ... Professional

432731085 432731086

432731087 432731088

432731089 432731090

Jetsave PNCs Description 988930001 Complete kit with 2 pumps, 550 ml/min

988930002 Complete kit with 3 pumps, 550 ml/min

988930003 Complete kit with 4 pumps, 550 ml/min

988930004 Complete kit with 5 pumps, 550 ml/min

Acessories PNCs Description 988916611 Single low level probe

432930071 Extension POWER cable (6m)

432930072 Extension DATA cable (6m)

Power supply

From the washer extractor: 100–240V~ 50/60 Hz / 0.1A (Max)

Electrolux name and description Packaging 20 litres Packaging 10 litres

W01 - lagoon Sensitive Detergent Professional detergent for natural/animal fiber

W03 - lagoon Sensitive Conditioner Professional conditioner for natural/animal fiber

W02 - lagoon Delicate Detergent Professional delicate universal detergent

For further information including spotting agents, please refer to the lagoon detergent Product Data Sheet

Page 7: lagoon® Advanced Care · Wool filling factor 1:15 kg Silk filling factor 1:18 kg Drum, volume litre diameter ø mm Extractionrpm G-factor Heating alternative electricity kW ... Professional

Experience the Excellenceprofessional.electrolux.com

Art.

No.

438

9139

10EN

/201

9.12

.19

We

rese

rve

the

right

to a

lter s

pec

ifica

tions

with

out

no

tice.

BASE; closed front and sides

Suitable for models: WH6-20LAC988918871 Height: 230 mmMaterial: Galvanised, silver grey painted steel

with stainless steel front panel.

BASE; “floating foundation”

Suitable for models: WH6-20LAC 988918872

Material: Galvanised, silver grey painted steel with stainless steel front panel.

Feature: A “floating foundation” filled with concrete eliminates noise to other parts of the building.