lagoon® Advanced Care · Wool filling factor 1:15 kg Silk filling factor 1:18 kg Drum, volume...
Transcript of lagoon® Advanced Care · Wool filling factor 1:15 kg Silk filling factor 1:18 kg Drum, volume...
PROFESSIONAL LAUNDRY
lagoon® Advanced CareWH6-20LAC and TD6-20LAC
The ideal replacement for any dry-cleaning operation
Features and benefitsKeep customers coming backOutstanding results for garments of every type thanks to specialized detergents and dedicated programs
Delicate on the delicatesGentle on fine textiles and wools labelled dry-clean only, as less mechanical action. Woolmark-approved
Rapid return on investmentWith a better loading factor, less prespotting, easier finishing and faster pro-cess times
Sustainable and eco-friendlyWater-based cleaning with none of the disadvantages of PERC, which can be dangerous to staff
Dry to dry in 1 hourSmart chemicals and processes mean garments are fully dried in the dryer - no hang-dry
WH6-20LAC
20 14 10 180 725 1055 450 18.0
22 23 16 20 17 20
110 106 80 85 80 95
0.15/1.0 0.15/1.0 0.05/0.6 0.15/1.0 0.05/0.95 0.05/0.7
65 113+10 0.5/2.2/0.55 45
TD6-20LAC
20360 755 18.021.025.0 6.5
19 18 16 24 16 15 14 21 12 12 10 29
27 26 23 44 8.2 9.3 9.9 2.99 302 321 352 185 1.00 1.13 1.21 0.36
Main specificationsMax. capacity Laundry filling factor 1:9 kg
Wool filling factor 1:15 kg Silk filling factor 1:18 kg
Drum, volume litre diameter ø mm
Extraction rpm G-factorHeating alternative electricity kWConsumption data ”lagoon” Total time Wool High min
Wool Medium min Silk min Synth. mix Medium min Synth. mix Low min Curtains min
Water consumption (cold+hot) Wool High litre Wool Medium litre Silk litre Synth. mix Medium litre Synth. mix Low litre Curtains litre
Energy consumption (motor/heating/water) Wool High kWh Wool Medium kWh Silk kWh Synth. mix Medium kWh Synth. mix Low kWh Curtains kWh
Consumption data ECO 60 1:9* Total time min Water consumption (cold+hot) litre Energy consumption (motor/heating/hot water) kWh Residual moisture % * Water temperature 15°C cold water and 65°C hot water.
* 1:30 load 100% wool load at 30% initial moisture dryed to 0%.** 1:40 load 100% synthetic load at 20% initial moisture dryed to 0%.*** At rated capacity 100% cotton load at 50% initial moisture dryed to 0%.
Main specificationsMax. capacity Drying filling factor 1:18 kgDrum, volume litre
diameter ø mm Heating alternative electricity kW
gas BTU/h (kW) steam at 700 kPa heat pump kW
Consumption data ”lagoon”
Total time Wool High* min Wool Medium* min Synthetic mix** min
Consumption data***
Total time min Energy consumption (motor/heating/hot water) kWh Evaporation g/min Energy/Water evaporation kWh/l
El Gas Steam Heat pump
WH6-20LAC
20 200-600
307517015
300-6005
17.6 4.2 ± 1.0
84/68 66/50
5
354 1.66
x x x
970 947 1412 461 526 1511 1130 150 1329 402 302 1288 1208 348 100 333 342 217
220-240V 3 ~ 50/60 18.0 18.5 50 380-415V 3N/3 ~ 50/60 18.0 18.5 35 440V 3 ~ 60 18.0 18.5 25 480V 3 ~ 60 18.0 18.5 25
220-480V 1 ~ 50/60 - 2.5 10
A
C
3
1
2
B
E
D2D1
IJG
74
N
H
LK
10
11
F
8M O
9
5 Q6
P
Rear
Side view
Front
Electrical connections Heating Main voltage Heating Total Recommended alternative power power fuse
Hz kW kW A
Electric heated
Steam or Non heated
* Total power and recommended fuse does not depend on the heating power in those cases.
Water and steam connection
Water valves DN Water pressure kPa Capacity at 300 kPa l/min Drain valve ø mm Draining capacity l/min Steam valve DN Steam pressure kPa Liquid detergent supplies
Floor requirements
Frequency of the dynamic force Hz Floor load at max extraction kN
Sound levels
Sound power/pressure level at extraction* dB(A) Sound power/pressure level at wash* dB(A)
Heat emission
% of installed power, max
Shipping data**
Weight net, kg Shipping volume m3
Accessories
Steel base Hose kits for water or steam Fluff collector
Dimensions in mm
A Width B Depth C Height D1 D2 E F G H I J K L M N O P Q
1 Display 2 Door opening ø 435 mm 3 Detergent box 4 Cold water 5 Hot water 6 Cold/Hot water
7 Re-used water 8 Drain valve
9 Liquid detergent supply 10 Electrical connection 11 Steam connection
* Sound power levels measured according to ISO 60704.** Average data. Crated weight/shipping volume depends on configuration.
Please contact logistics for exact measures.
220-230V 3 ~ 50/60 18.0 19.0 50 240V 3 ~ 50/60 18.0 19.0 50 380-415V 3N ~ 50/60 18.0 19.0 35 440V 3 ~ 50/60 18.0 19.0 35 480V 3 ~ 60 18.0 19.0 25
220-240V 3 ~ 50/60 * 1.0 10 380-415V 3N ~ 50/60 * 1.0 10
440V 3 ~ 50/60 * 1.0 10 480V 3 ~ 60 * 1.0 10
TD6-20LAC
1” 100-1000
65 1”
1/2”
2000 20
2800-5000 28-50 200 525 600 690 650 650 650
72/56
15
243 2.07
790 1202 1342 1771 773 836 750 110 62 270 240 174 605 739 396
1
2
A
C
I
3
J
K
G
H
4
5
7
N
3
L
M
6
J
K
5
B(a) D
EF
B(b)
Front
Left side
Electrical connections Heating Main voltage Heating Total Recommended alternative power power fuse
Hz kW kW A
Electric heated
Gas heated/ Steam heated
Rear side
El, gas Steam
* Total power and recommended fuse does not depend on the heating power in those cases.
* Sound power levels measured according to ISO 60704.** Average data. Crated weight/shipping volume depends on configuration.
Please contact logistics for exact measures.
Steam, gas and air connections
Steam ISO 7/1-R Steam pressure kPa Steam consumption kg/h Condensate ISO 7/1-R Gas ISO 7/1-R Gas pressure
Natural gas Pa mbar
Propane Pa mbar
Air outlet ø mm Evacuated air, el 18.0 kW m3/h
gas 21.0 kW steam 25.0 kW
Pressure drop el 18.0 kW Max. Pa gas 21.0 kW steam 25.0 kW
Sound levels
Sound power/pressure level at drying* dB(A)
Heat emission
% of installed power, max
Shipping data**
Weight kg Shipping volume crated, m3
Dimensions in mm
A Width B(a) Depth, el and gas B(b) Depth, steam C HeightD E F G H I JK L M N
1 Operating panel 2 Door opening ø 580 mm 3 Electrical connection on gas heated machines 4 Gas connection/Electrical connection on electrical heated machines5 Exhaust connection6 Condensate connection7 Steam connection
220-240V 1/1N ~ 50/60 * 5.5 25 380-415V 3/3N ~ 50/60 * 6.5 10
TD6-20LAC
72/56
15
308 2.15
790 1202 1229 1771 773 836 750 110 270 123 262
D
EF
B(a)
B(b)
1
2
A
C
J
4
G
H
3
I
Electrical connections Heating Main voltage Heating Total Recommended alternative power power fuse
Hz kW kW A
Heat pump
* Total power and recommended fuse does not depend on the heating power in those cases.
* Sound power levels measured according to ISO 60704.** Average data. Crated weight/shipping volume depends on configuration.
Please contact logistics for exact measures.
Sound levels
Sound power/pressure level at drying* dB(A)
Heat emission
% of installed power, max
Shipping data**
Weight kg Shipping volume crated, m3
Dimensions in mm
A(a) Width B(a) Depth B(b) Depth C HeightD E F G H I J
1 Operating panel 2 Door opening ø 580 mm 3 Electrical connection 4 Drain for condense water
Front
Left side
Rear side
432731085 432731086
432731087 432731088
432731089 432731090
Jetsave PNCs Description 988930001 Complete kit with 2 pumps, 550 ml/min
988930002 Complete kit with 3 pumps, 550 ml/min
988930003 Complete kit with 4 pumps, 550 ml/min
988930004 Complete kit with 5 pumps, 550 ml/min
Acessories PNCs Description 988916611 Single low level probe
432930071 Extension POWER cable (6m)
432930072 Extension DATA cable (6m)
Power supply
From the washer extractor: 100–240V~ 50/60 Hz / 0.1A (Max)
Electrolux name and description Packaging 20 litres Packaging 10 litres
W01 - lagoon Sensitive Detergent Professional detergent for natural/animal fiber
W03 - lagoon Sensitive Conditioner Professional conditioner for natural/animal fiber
W02 - lagoon Delicate Detergent Professional delicate universal detergent
For further information including spotting agents, please refer to the lagoon detergent Product Data Sheet
Experience the Excellenceprofessional.electrolux.com
Art.
No.
438
9139
10EN
/201
9.12
.19
We
rese
rve
the
right
to a
lter s
pec
ifica
tions
with
out
no
tice.
BASE; closed front and sides
Suitable for models: WH6-20LAC988918871 Height: 230 mmMaterial: Galvanised, silver grey painted steel
with stainless steel front panel.
BASE; “floating foundation”
Suitable for models: WH6-20LAC 988918872
Material: Galvanised, silver grey painted steel with stainless steel front panel.
Feature: A “floating foundation” filled with concrete eliminates noise to other parts of the building.