Laboratory Sample Result Electronic Submission

29
Laboratory Sample Result Electronic Submission Lab to State 2.0 and Electronic Submission

description

Laboratory Sample Result Electronic Submission. Lab to State 2.0 and Electronic Submission. Conference Call Etiquette. Please MUTE your phone , this helps to reduce background noise and static. You can do this by pressing * 6 , then press again to un-MUTE. - PowerPoint PPT Presentation

Transcript of Laboratory Sample Result Electronic Submission

Page 1: Laboratory Sample Result Electronic Submission

Laboratory Sample Result Electronic

Submission

Lab to State 2.0 and Electronic Submission

Page 2: Laboratory Sample Result Electronic Submission

Conference Call Etiquette Please MUTE your phone, this helps to reduce

background noise and static. You can do this by pressing * 6 , then press again to un-MUTE.

If you can not MUTE your phone, please refrain from having conversations with coworkers on your end.

If you must make a call on your phone, it may be best to hang up the conference call on your line, and dial in again afterwards. Please don’t put us on Hold!

Page 3: Laboratory Sample Result Electronic Submission

Laboratory Electronic SubmissionWeb Seminar Training

Changes in Reporting Methods The CSV Template

Sample.csv Result.csv MonitoringSchedule.csv

Web site tools Questions

Page 4: Laboratory Sample Result Electronic Submission

Changes in Reporting Methods The Office of Drinking Water (ODW) will implement a

new electronic reporting system at the end of January, 2009.

The new system, in addition to bacteriological results, will allow laboratories to submit inorganic and organic chemical, physical and radiological results.

Page 5: Laboratory Sample Result Electronic Submission

Changes in Reporting Methods

We have selected an Environmental Protection Agency (EPA) developed application: SDWIS/Lab to State 2.0. CSV templates sent to ODW are uploaded through this system.

This application is compliant with EPA electronic reporting standards in the Cross-Media Electronic Reporting Regulation (CROMERR).

Page 6: Laboratory Sample Result Electronic Submission

CSV Templates: Fields and Submission Requirements

CSV Templates Introduction and Requirements Sample.csv

New Fields and Data Requirements Result.csv

New Fields and Data Requirements MonitoringSchedule.csv and tabs within this file File saving procedure and requirements Examples

Page 7: Laboratory Sample Result Electronic Submission

CSV Templates:Introduction and Requirements

Page 8: Laboratory Sample Result Electronic Submission

File format: What does a .CSV file look like?

The .CSV (Comma Separated Values) file appears below as it might be viewed when opened in excel and notepad:

Page 9: Laboratory Sample Result Electronic Submission

CSV Templates: Submission Requirements

Both the sample.csv and result.csv files must be completed and submitted for data to be accepted into the ODW database.

sample.csv contains the information identifying a sample, result.csv contains the analytical result of the sample.

Page 10: Laboratory Sample Result Electronic Submission

Sample.csvFields and Requirements

Page 11: Laboratory Sample Result Electronic Submission

Sample.csv: Fields and Requirements

Sample.csv contains the identifying information of the sample.

The 1st column in the file must always read “sample.” No capitalization. This allows Lab to State 2.0 to recognize the type of data.

The 2nd column, or “Certifying Agency”, will be “STATE” for state-certified labs.

Lab ID, Sample ID, and PWSID have not changed from the last template. These MUST be duplicated on result.csv.

Page 12: Laboratory Sample Result Electronic Submission

Sample.csv: Fields and Requirements Sample Category identifies the sample as type coliform (TC), Lead and Copper (PB) or

General (GE). Classification Code further identifies the sample based on the sample category. Sample Type indicates the replacement type: Routine (RT), Repeat (RP), Special (SP),

etc. Compliance Indicator: “Y” or “N” indicates whether the sample is for compliance or

not.

ExamplesSample

CategoryClassification

Code Sample TypeCompliance

Indicator

Coliform P/A Routine TC TC RT Y

Coliform P/A Special TC TC SP N

Coliform P/A Repeat TC TC RP Y

MPNs GE MPN SP N

Lead and Copper PB LC RT Y

Total Haloacetic Acids (HAA5) GE HAA RT Y

Total TriHalomethanes (TTHM) GE THM RT Y

Benzene GE VOC RT Y

Page 13: Laboratory Sample Result Electronic Submission

Sample.csv: Fields and Requirements Facility ID is a new field that identifies a water system facility within a water

system with a specific ID, identified in the water system Monitoring Schedule. Sampling Point uniquely identifies a sampling point within the water system

facility. Refer to the Monitoring Schedule. Sample Location describes the address or location, i.e., “Kitchen Sink.”

PWSID

Water System Name

Facility ID

PWSFacility Description

Sample Category

Classification Code

Sample Type Compliance

Sampling Point

Sample Location

VA1000000ABINGDON GENERAL DS001 Distribution System TC TC RT Y TCR01  

VA2000000LEXINGTON GENERAL TP003 Chlorination System GE TOC RT Y RW001

RAW WATER SAMPLE

VA2000000LEXINGTON GENERAL EP006 Entry Point GE RAD RT Y EP001

LAB SAMPLE TAP

VA2000000LEXINGTON GENERAL TP003 Treatment Plant GE VOC RT Y UP001

COMBINED FILTER EFFL

VA2000000LEXINGTON GENERAL DS005

Distribution System 5 GE DBP RT Y DBP01

COUNTY ADM. BUILDING

VA2000000LEXINGTON GENERAL DS001

Distribution System 1 PB LC RT Y LCR01

MENS REST ROOM LOBBY

VA3000000SOUTHEAST

GENERAL DS001 Distribution System GE MPN RT N EP001TAP INSIDE BUILDING

Example: Monitoring Schedule

Page 14: Laboratory Sample Result Electronic Submission

Sample.csv: Fields and Requirements

Collect Date and Receive Date must have mm/dd/yyyy format. Leading zero’s must be included.

Collect Time must have hhmmss format. Example: 9:35 AM will be 093500.

Sampler Name: Enter name of sample collector. CL2 Residual: Leave blank if not analyzed, enter

0.0 if not detected, or enter actual numeric value of Total or Free CL2 residual. No special characters permitted, i.e. “<.”

Page 15: Laboratory Sample Result Electronic Submission

Sample.csv: Optional Fields The template fields in the darker green color are

optional. Reject: If sample is rejected, results should not

be provided in result.csv. Select reject reason from code list (on template and instructions.)

PB Type Code: If analyzing Lead and Copper samples, enter “FSD.”

Repeat Samples: Complete information for Original Sample Certifying Agency, Original Sample Lab ID and Original Sample ID.

Page 16: Laboratory Sample Result Electronic Submission

Result.csvFields and Requirements

Page 17: Laboratory Sample Result Electronic Submission

Result.csv: Fields and Requirements

Result.csv contains the analyte result for the sample.

The 1st column in the file must always read “result.” No capitalization. This allows Lab to State 2.0 to recognize the type of data.

Certifying Agency, Lab ID, Sample ID, and PWSID should be the same as on sample.csv, unless the sample was rejected.

Page 18: Laboratory Sample Result Electronic Submission

Result.csv: Fields and Requirements

The Analyte Code can be found in the Analyte Code Groups file as “SDWIS Code.” Example: Total Haloacetic Acids (HAA5’s) = 2456.

Standard Method – Standard analysis method code for analyte.

State Notification Date – enter date data is sent to state in mm/dd/yyyy format.

Data Quality – Indicates whether the analytical result meets established data criteria (Accepted = A, Rejected = R.)

Page 19: Laboratory Sample Result Electronic Submission

Result.csv: Fields and Requirements

Microbe Presence Indicator (Bacti ONLY) – Enter “P” for Positive microbial result, “A” for negative result.

Count (MPN ONLY) – Enter a value for a positive microbial result, or “0” for a negative result.

Volume (MPN ONLY) – Volume Assayed for MPN, i.e. “100ML.”

Count Type (MPN ONLY) – Enter “MPN.”

Page 20: Laboratory Sample Result Electronic Submission

Result.csv: Fields and Requirements

Less Than Indicator (GE or PB ONLY) – Enter “Y” if analytical result is less than Lab Reporting Level (MRL) or Federal Minimum Detection Limit (MDL). Enter “N” if result exceeds level.

Less Than Code (GE or PB ONLY) – Code for reporting level used, “MRL” or “MDL.”

Detection Level – Enter detection level used by lab if “MRL” was entered for reporting code.

Detection Unit Measure – Unit of measure associated with detection level used by lab if “MRL” was entered.

Concentration – Enter a concentration value if the analytical result was reported as exceeding MRL or MDL.

Concentration Unit Measure – Enter unit measure associated with the concentration value.

Note: “GE or PB ONLY” does NOT include MPN

Page 21: Laboratory Sample Result Electronic Submission

Monitoring Schedule and Analyte Code Groups

Page 22: Laboratory Sample Result Electronic Submission

Monitoring Schedule and Analyte Code Groups

The ‘MonitoringSchedule’ files can be found on the ODW website. Enter your PWSID list into the Monitoring Schedule to retrieve FacilityID, Sampling Point information.

Helpful tools such as “Std. Methods Analytes assoc.” and “AnalyteCodeGroups” can be found in the tabs of the Monitoring Schedule. These are useful in obtaining the correct

Standard Method code and Sample Category – Classification Code pairing.

Page 23: Laboratory Sample Result Electronic Submission

Other Resources found on the Website

The ‘State Classified Water Quality List’ is a complete listing of required water quality parameters organized by panels. Classification codes and Analyte codes are also conveniently listed here.

The ‘Common Non-Regulated Parameters’ list follows the State Classified Water Quality List and offers common non-regulated analytes that may be detected and reported to ODW.

The ‘Template: CSV Format’ provides links to download the sample and result templates, and complete instructions and descriptions for each column.

The ‘CSV Examples’ is a good place to start when filling out CSV templates. Four links are provided: 1 Bacti sample template, 1 Bacti result template; 1 Chemical sample template; 1 Chemical result template. Bacti and Chemicals can be submitted together, but be careful of filling out all the right columns!

The ‘Template: XML Format’ offers instructions on how to submit with XML.

Page 24: Laboratory Sample Result Electronic Submission

File Saving Procedure and Requirements

Page 25: Laboratory Sample Result Electronic Submission

CSV Template: File Saving Procedure and Requirements

If using the Template_sample.xls and Template_result.xls to enter sample data, in order to submit it is necessary to: Delete the first row containing header names Save each file separately with the following format:

Lab Certification ID_BeginDate(yymmdd)_EndDate(yymmdd)_sampleExample: 00900_051107_051111_sample

Save with file type CSV (COMMA DELIMITED) *.csv

It is recommended that you also save a copy with file type .xls in order to make edits.

Page 26: Laboratory Sample Result Electronic Submission

CSV Template: File Saving Procedure and Requirements

You may get a few warnings from excel when saving your .csv template.

“The selected file type does not support workbooks that contain multiple sheets.” Click “OK”

“The file.csv may contain features that are not compatible with CSV. Do you want to keep the workbook in this format?” Click “Yes” to keep this format, which leaves out any incompatible features.

Page 27: Laboratory Sample Result Electronic Submission

CSV Template: File Saving Procedure and Requirements

Once you have saved your file as .csv, do NOT open the .csv file to modify. You will lose the formatting required to submit without errors.

If you would like to modify the file, open the original .xls file, modify, and save again as a .csv file. Or, you can modify the .csv file directly in Notepad.

You will submit both the sample.csv and result.csv at the same time to [email protected]

Submit only new samples each time…do not re-submit samples.

Page 28: Laboratory Sample Result Electronic Submission

Examples

Page 29: Laboratory Sample Result Electronic Submission

Any Questions?