Laboratory Equipment The figure was adopted from (Dec 2006).

33
Laboratory Equipment The figure was adopted from http://vip.busytrade.com/huaou (Dec 2006)

Transcript of Laboratory Equipment The figure was adopted from (Dec 2006).

Page 1: Laboratory Equipment The figure was adopted from  (Dec 2006).

Laboratory Equipment

The figure was adopted from http://vip.busytrade.com/huaou (Dec 2006)

Page 2: Laboratory Equipment The figure was adopted from  (Dec 2006).

volumetric cylinders

watch glasses

beakers

The figures were adopted from z http://vip.busytrade.com/huaou (Dec 2006)

Page 3: Laboratory Equipment The figure was adopted from  (Dec 2006).

volumetric flasks

The figures were adopted from http://vip.busytrade.com/huaou and http://www.silcom.com/~adbrown/tutor/images/Vol-flask.gif (Dec 2006)

Page 4: Laboratory Equipment The figure was adopted from  (Dec 2006).

measuring of a precise volume

„meniscus“= a concave

upper surface that forms on a

liquid in a tube as a result of

surface tension

Page 5: Laboratory Equipment The figure was adopted from  (Dec 2006).

filling the volumetric flask

Page 6: Laboratory Equipment The figure was adopted from  (Dec 2006).

glass pipettes

filling the pipette using the pipette pump

pipette pump

Page 7: Laboratory Equipment The figure was adopted from  (Dec 2006).

insertion of the pipette into the pipette pump: carefully, but tightly

Page 8: Laboratory Equipment The figure was adopted from  (Dec 2006).

meassuring of a precise volume of 5

mL

4,49 mL 4,85

mL

5,0 mL

The figures are from http://www.uwplatt.edu/chemep/chem/chemscape/labdocs/catofp/measurea/volume/pipet/page.htm (Dec 2006)

Page 9: Laboratory Equipment The figure was adopted from  (Dec 2006).

measuring out a precise volume by the doser

dosertest tubes holder

Page 10: Laboratory Equipment The figure was adopted from  (Dec 2006).

doser

storage bottle

dosing plunger

wheel for volume

adjustment

Page 11: Laboratory Equipment The figure was adopted from  (Dec 2006).

titrimetric flask

burette

„titration“

Page 12: Laboratory Equipment The figure was adopted from  (Dec 2006).

burette

burette filler

graduated tube

storage bottle

dosing stopcock

Page 13: Laboratory Equipment The figure was adopted from  (Dec 2006).

filling the burette

using the burette

Page 14: Laboratory Equipment The figure was adopted from  (Dec 2006).

automatic pipette

Page 15: Laboratory Equipment The figure was adopted from  (Dec 2006).

plastic tip pipetting button

emptying filling

The figure was adopted from the CD-ROM: Encyklopedie laboratorní medicíny pro klinickou praxi 5. Kolektiv autorů, ed. A. Jabor,M. Zámečník, SEKK s r.o., Pardubice, Katedra klinické biochemie IPVZ Praha, 2005, hypertext.

ISBN 80-238-9775-6

Page 16: Laboratory Equipment The figure was adopted from  (Dec 2006).

the pipette can be used solely with a plastic tip

Page 17: Laboratory Equipment The figure was adopted from  (Dec 2006).

automatic pipette for the volume range: 10 – 100 l

yellow tip is destined for „yellow pipette“

Page 18: Laboratory Equipment The figure was adopted from  (Dec 2006).

automatic pipette for the volume range: 10 – 100 l

yellow tip is destined for „yellow pipette“

Page 19: Laboratory Equipment The figure was adopted from  (Dec 2006).

automatic pipette for the volume range: 100 – 1000 l

blue tip is destined for „blue pipette“

Page 20: Laboratory Equipment The figure was adopted from  (Dec 2006).

automatic pipette for the volume range: 100 – 1000 l

blue tip is destined for „blue pipette“

Page 21: Laboratory Equipment The figure was adopted from  (Dec 2006).

volume adjustment of the automatic pipette

Never adjust volume out ofthe allowed range!

turn slowly

Page 22: Laboratory Equipment The figure was adopted from  (Dec 2006).

stendby 1st position 2nd position

holding the pipette

Page 23: Laboratory Equipment The figure was adopted from  (Dec 2006).

filling emptying

Pipetting step by step

1st stendby 1st 2nd

The figure is from: Encyklopedie laboratorní medicíny pro klinickou praxi 5. Kolektiv autorů, ed. A. Jabor, M. Zámečník, SEKK s r.o., Pardubice, Katedra klinické biochemie IPVZ Praha, 2005, hypertext. ISBN 80-238-9775-6

Page 24: Laboratory Equipment The figure was adopted from  (Dec 2006).

Removing of solution drops from the tip surface

the drops can be removed only in a direction from up to down

Page 25: Laboratory Equipment The figure was adopted from  (Dec 2006).

stendby position 1st position

(= filling the pipette)

Page 26: Laboratory Equipment The figure was adopted from  (Dec 2006).

emptying the pipette (2nd position)

Page 27: Laboratory Equipment The figure was adopted from  (Dec 2006).

tip ejector button

Page 28: Laboratory Equipment The figure was adopted from  (Dec 2006).

spectrophotometer

Page 29: Laboratory Equipment The figure was adopted from  (Dec 2006).

pH meter

with an electrode immersed into buffer solution

Page 30: Laboratory Equipment The figure was adopted from  (Dec 2006).

chromatographic chamber

with a thin layer inside (TLC chromatography)

Page 31: Laboratory Equipment The figure was adopted from  (Dec 2006).

fume cupboar

d

chromatographic chambers

Page 32: Laboratory Equipment The figure was adopted from  (Dec 2006).

water bath (thermostat)

Page 33: Laboratory Equipment The figure was adopted from  (Dec 2006).

equipment for gel electrophoresis

power suply (direct current)

electrophoresis chamber

applicator

containers for staining and destaining gel