lab companion
-
Upload
kossodo-sac -
Category
Documents
-
view
456 -
download
25
description
Transcript of lab companion
Laboratory Equipment • Heating Baths• Shaking Heating Baths• Viscometer Heating Baths• Heating Bath Circulators• Refrigerated & Heating Bath Circulators• Desiccators • Clean Benches• Ductless Fume Hoods• PCR Workstations• UV Sterilization Cabinets• General Incubators• Low Temperature Incubators• Incubated & Refrigerated & Illuminated Shakers• Forced / Natural Convection Ovens• Vacuum Ovens• Electrical Aspirator Pumps• Recirculating Coolers (Chillers)• Low Temp. Recirculating Coolers (Chillers)• General Purpose Laboratory Refrigerators• Pharmacy Refrigerator • General Purpose Laboratory Freezer• Open-Air Shakers• Rocking & Waving Shakers• Separatory Funnel Shakers • Magnetic Stirrers – Scale, Digital & Multi Position • Overhead Stirrers – Economic, Anlogy & Digital• Vortex Mixer – Economic & Basic • Flask Support• Ultrasonic Cleaners• Magnetic Drives
Environmental Testing Equipment• Plant Growth Chambers• Temperature & Humidity Chambers• Clean Temperature & Humidity Chambers• Low Temperature Chambers• Incubators• Low Temperature Incubators• Incubated Shakers• Shaking & Heating Baths • Fingerprint Development Temp. & Humid. Chambers
Industrial Reliability Testing Equipment• Temperature & Humidity Chambers• General Recirculating coolers (Chillers)• Low Temp. Recirculating Coolers• Vacuum Ovens• Temperature Chambers
* Custom-Designed Equipment
Baths & Circulators
Desiccators
Fume Hoods
Incubators
Ovens
Pumps
Recirculating Coolers (Chillers)
Laboratory Refrigerators & Freezers
Shakers
Stirrers & Vortex Mixer
Environmental Chambers
Other
2011~2012
Lab Companion• Lab Companion Korea - International head office #1005, Byucksan Digital valley 6-cha, 481-4 Gasan-Dong, Geumcheon-Gu, Seoul 153-803, Korea Tel +82 2 2627 3816 Fax +82 2 3143 1824 e-mail [email protected]
• Lab Companion U.S.A. 1-A Gill st. Woburn, MA 01801, U.S.A. Tel +1 781 376 0700 Fax +1 781 376 0704 e-mail [email protected]
• Lab Companion Europe Unit 3, Tower Industrial Park, Chalgrove, Oxfordshire, OX44 7XZ, United Kingdom Tel +44 1865 400321 Fax +44 1865 400736 e-mail [email protected]
• Lab Companion China RM107, No.68 Line, 569 Xin Hua Road, Shanghai, 200052 China Tel +86 21 6294 0608 Fax +86 21 6294 0602 e-mail [email protected]
• Lab Companion SEA (South East Asia) No.7A, Jalan Kemboja 1 B/2, 48300 Bandar Bukit Beruntung, Selangor Darul Ehsan, Malaysia Tel +60 603 6028 5833 Fax +60 603 6028 5822 e-mail [email protected]
Dr. Kim, Jin-Eog
is proud to introduce to you in this catalogue, our new line of Y2011 Laboratory and Environmental Testing Equipments. We are taking the next step forward and eager to take on new challenges in creating a product right for you! In the world inside physics and chemistry our reliable instruments will help aid you in the growth and evolution in any field of research. We are driven by innovation and our extensive arrays of products are cutting-edge in the scientific and industrial research industries and specialized markets.
Through continuous focus on human resources, acquisition of technology, and overcoming new challenges, we have set forth on preserving and strengthening our Jeio Tech cornerstone in maintaining to be one of the Global Leading Companies in the manufacturing and distributing of Laboratory and Environmental Testing Equipments.
JEIO TECH's number one priority is to provide the world's best products and services through outstanding quality and customer satisfaction.
Founder & President
JEIO TECH
Jeio tech Co,. Ltd Established
CE/UL - Accredited international certificates (Y2010 acquired "CE marks" - 38 models 158 products)
Participated in international exhibition; ACHEMA, Pittcon, Arab lab, Analytica and etc.
Strong Worldwide network· Lab Companion overseas branch in China, U.K, Malaysia, & U.S.A.
· Jeio Tech works with more than 300 distributors and dealers worldwide.
Annual technical seminar and service training
Leading company of scientific and industrial instrument manufacturer ·Leader of Korean markets share.
·Average 20% of growth rate annually. ·Wide field of laboratory and industrial products.
(Thermal, refrigerating, pressure, humidity,and cleaning conditions)·Set up the one-step solution for all your laboratory needs.
From scientific research and development to industrial reliable test for perfect simulation of enviromental conditions.·Developed newly build mass production of 2nd high-tech manufacturing facility (Y2011) in Dae Jeon techno valley.
(Show room, warehouse, R & D center and etc)
History of JEIOTECH
ISO 9001 certification received
Over 18 Own technology patents certificated in Korea and U.S.A
Organized the Institute of Technology
Launched of Lab Companion brand
1991 ~ 1999Growth and Consolidation in
Company founded in
1988 ~ 1990
Becoming a Global Player in
2000 ~ Now
Lab Companion is seeking for the global standard.
Lab Companion which is JEIO TECH's laboratory instrument brand is well known for its guaranteed quality since 1989.
We have being organized high quality one-stop manufacture system on sheet metal work, metallic moldings, coating, assembling.
We keep trying to give our clients maintenance-free, user-friendly and safe operation. � e 'Lab Companion' is continuously growing and developing into an international brand value, and best products for reliable results.
We are striving exceptional service to become the � rst choice of our customers, to improve customer value enhancement with high- quality engineering and advanced organization.
Ergonomic design system helps to maintain the units easily and to be free from frequent mechanical trouble.
Qualified worldwide service team - Engineering and sales managing specialists always provide tailored service.
Based on over 20 years of temperature control technical experience, our highly integrated engineering team focuses on always striving to provide di� erentiated values from competition. Jeio tech have manufactured the basic metal processing to � nal inspection processes are strictly under controlled to try to deliver the best products for valued clients.
Our professorial engineer know-how will never cease to build up its reputation as the � rst partner for customer's needs.
Valuable & Reliable production system
Enable to do anything!
Valuable and Progressive Service Know-How
JEIO TECH - Lab Companion obtained ISO 9001: 2008 / CE / UL certi� cation in order to raise the customer satisfaction of its superior technology and quality. Certi� cates
Product Catalog &Technical Highlight Worldwide Relationship
We are representing as a high level of technical instrument manufacturer throughout Korea and worldwide. Over 60 countries -Intimate relationship with our partners and logistics providers Worldwide.
Periodically communicate and instruct with the latest technology and service principles.
All our partnership groups are very quali� ed and enthusiastic to keep providing the best solution for your laboratory needs.
CLS-Safety Control SystemCLS (Custom Logical Safe) Control System
Our years of technical know-how develops a maximized safety control system-CLS Control System with adjustable warning and safety functions for user safety and convenience.
All the instruments of JEIO TECH show much safer operation with independent safety device and circuit when electric and electronic system trouble occurred even during the operation. (Patented)
CFC-Free(Green Mark)
Protect the Global Environment
All JEIO TECH products use HFC refrigerant which causes NO damage to ozone layer. Complies with the measures for ozone layer protection speci� ed by the Montreal Protocol
BDBC2-Fuzzy Control SystemBDBC2-Fuzzy Control System
Temp. & Humid. Fuzzy Control System design allows our Temp. & Humid. chambers provide extended very low-temp. with stable humidity control range.
Also, the system optimize and increase energy e� ciency by cascading refrigeration and heating controls adjusting for humidi� cation, and dehumidi� cation. (Patented)
Balan
ced D
ehumidifying & Bath Cooling
Fuzzy Control System
Balan
ced D
ehumidifying & Bath Cooling
Fuzzy Control System
GD mark Award of good designed products
A Design Award only awarded for well-designed Korean manufactured products that have passed the criteria in product aesthetics, relationship with the user, environmental awareness, economic considerations, and consumer satisfaction.
Jeio Tech’s expertise lies in not only in our well-executed designs but we are thoroughly alive with ideas and cu� ing-edge designs.
1) Products without refrigerators · Specifications are under room temperature 25℃, no load. ·Applicable operation temperature range is 15 to 40℃.
2) Products with refrigerators · Specifications are under room temperature 20℃, no load. ·Applicable operation temperature range is 18 to 35℃. * Except for Temperature (& Humidity) Chambers. (P. 114-146)
3) All product spec can be changed without prior notice subject to our performance improvement and quality control of products
4) Communication to PC (Software + Cable) PC Control Software ·Display of temp. values and effective heating / cooling capacity on PC. ·Programming and recording of time parameter and individual temp. profile.
5) Our Web-site includes detailed information of all JEIO TECH products with recent technical data
Please visit www.jeiotech.com
� e contents of this catalogue are based on the below unless otherwise speci� ed.
Table of Contents
10 Heating Baths13 Shaking Heating Baths14 Viscometer Heating Baths15 Heating Bath Circulators16 Refrigerated & Heating Bath Circulators18 Cold Trap Baths
Baths & Circulators8
22 Cubic Vacuum Desiccators22 Round Vacuum Desiccators
Desiccators22
26 Clean Benches30 Ductless Hume Hoods34 PCR Workstations34 UV Sterilization cabinet
Fume Hoods24
40 Incubators42 Low Temperature Incubators45 Low Temperature Personal Incubators46 Incubated & Refrigerated & Illuminated Shakers
Incubators38
68 Electrical Aspirator Pumps69 Rotary Vacuum Pumps
Pumps68
58 Forced Convection Ovens63 Natural Convection Ovens66 Vacuum Ovens
Ovens56
82 General Purpose Laboratory Refrigerators82 Pharmacy Refrigerators82 General Purpose Laboratory Freezers
Laboratory Refrigerators & Freezers80
90 Advanced Orbital Shakers92 Dual-Action Shakers93 Economic Shakers94 Mini Shakers95 Rocking & Waving Shakers96 Separatory Funnel Shakers
Shakers86
114 Temperature [& Humidity] Chambers128 Temperature [& Humidity] Chambers-Tabletop Type137 Finger Print Temperature & Humidity Chambers140 Clean Temperature & Humidity Chambers146 Plant Growth Chambers
Environmental Chambers112
151 Flask Supports152 Ultrasonic Cleaners154 Magnetic Drives
Other150
156 Technical Data160 INDEX
Appendixes155
104 Magnetic Stirrers 106 Overhead Stirrers 108 Vortex Mixers
Stirrers & Vortex Mixer102
72 Recirculating Coolers - Basic type74 Low Temp. Recirculating Coolers - General Type76 Low Temp. Recirculating Coolers - Intelligent Type
70 Recirculating Coolers (Chillers)
Economy Heating Baths.Heating Baths.Viscometer Heating Baths.
Shaking Heating Baths.Heating Baths Circulators.Refrigerated & Heating Bath Circulators.
Baths & Circulators
Heating Baths
Description Working Temp. Range [℃/℉]
Bath Volume[L/cu ft]
TemperatureStability [±℃/℉] Page
Analog type (Economic)
BW-05BAmb. +7 to 100/ Amb. +12 .6 to 212
3.5 / 0.10.5 / 0.9 10BW-10B 11.5 / 0.4
BW-20B 20.0 / 0.7
Digital type (Economic)
BW-05HAmb. +5 to 100/ Amb. +9 to 212
3.5 / 0.10.1 / 0.18 10BW-10H 11.5 / 0.4
BW-20H 20.0 / 0.7
Dual type (Economic)
BW-0505HAmb. +5 to 100/ Amb. +9 to 212
3.5 & 3.5 / 0.1 & 0.1
0.1 / 0.18 10BW-0510H 3.5 & 11.5 / 0.1 & 0.4BW-1010H 11.5 & 11.5 / 0.4 & 0.4BW-1020H 11.5 & 20.0 / 0.4 & 0.7
General PurposeBW-05G
Amb. +5 to 100/ Amb. +9 to 212
5.0 / 0.20.2 / 0.36 12BW-10G 10.0 / 0.4
BW-20G 20.0 / 0.7
Shaking & Heating
BS-06Amb. +5 to 100/ Amb. +9 to 212
17.0 / 0.6
0.2 / 0.36 13BS-11 25.0 / 0.9BS-21 37.0 / 1.3BS-31 55.0 / 1.9
Viscometer VB-25G Amb. +5 to 150/ Amb. +9 to 302
25.0 / 0.9 0.05 / 0.09 14VB-40G 40.0 / 1.4 0.1 / 0.18
Bath Circulators
Description Working Temp. Range [℃/℉]
Bath Volume[L/cu ft]
TemperatureStability [±℃/℉] Page
Heating
CW-05GAmb. +5 to 150/ Amb. +9 to 302
5.0 / 0.2 0.05 / 0.09
15CW-10G 10.0 / 0.4 0.05 / 0.09 CW-20G 20.0 / 0.7 0.1 / 0.18 CW-30G 30.0 / 1.1 0.1 / 0.18
Refrigerated & Heating(to -25℃)
RW-0525G -25 to 150/ -13 to 302
5.0 / 0.2 0.05 / 0.09
16RW-1025G 10.0 / 0.4 0.05 / 0.09 RW-2025G 20.0 / 0.7 0.05 / 0.09RW-3025G 30.0 / 1.1 0.08 / 0.14
Refrigerated & Heating(to -35℃)
RW-0540G -35 to 150/ -31 to 302
5.0 / 0.2 0.05 / 0.09
16RW-1040G 10.0 / 0.4 0.05 / 0.09 RW-2040G 20.0 / 0.7 0.05 / 0.09 RW-0540G 30.0 / 1.1 0.08 / 0.14
Cold Trap BathDescription Working Temp. Range [℃/℉] Bath Volume [L/cu ft] Page
Cold Trap CTB-10 Down to -40 / -40 4.8 / 0.17 18
Accessories & OptionsDescription Page
for Baths & Circulators 20-21for Viscometer Heating Baths 21for Shaking Heating Baths 19
Selection Guide
Safety functions1) Self-protecting cut-off function and signal: - For over temperature, the power supply is
automatically cut from the heater and controller systematically before the unit shuts down.
- 2 separated over-current fuses for user safety.
2) Time setting function for automated run / off: - Integrated time setting: Delayed ON / OFF.
(from 1 min to 99 hr 59 min) - Operating settable function: After a power
interruption, select automated run or manual run.
3) Low fluid level and dry-running protection: - Intermittent tone alert sounds and optical
signals alarms display on the control panel. - Heating element automatically stop soon after
the alarm has been triggered to protect the user and samples.
* Except for BW-B/H series.
Optimum control performance1) Professional electronic controls and program
control : (Except for BW-B series) - Microprocessor PID temperature control with
very simple calibration and auto-tuning features. - Conveniently preset 3 most commonly used
temperature settings. - Select between Celsius and Fahrenheit.
2) Applicable control display considering HMI (Human Machine Interface) network system:
- Similar key arrangements throughout all our products.
- Splash-proof / easy-to-clean keypads and clear LED displays.
- A quick lock button prevents accidental resetting of parameters.
* Except for BW-B/H series.
Ideal construction1) High quality 304 grade stainless steel interior
bath and dirt-repellent powder coating external surface.
2) All wetted parts are made of stainless steel, making it corrosion-resistant allowing users to use bath fluids other than water.
3) Leak-proof, corrosion-resistant, seamless, deep-drawn and rounded corner baths for easy cleaning.
Technical Benefits
General ApplicationsGeneral Applications
Baths & CirculatorsBW-Series BS-Series CW, RW-Series
Bacteriological Examinations • •Coagulation Tests • • •Coliform Determinations • •Crude Oil Research • •Cytochemistry Examinations •Demulsibility Research • •Enzyme Studies •Food Processing QC • •Genetic Studies • • •Hormone Studies • •Immunological Research • • •Incubation for Microbiological Assays • • •Molecular Biology • • •Protein Studies • •Serological tests • • •Thawing Cryopreservation Vials •Tissue Culture Studies • • •Virology Research • • •Warming Reagents • •Water Quality Research • • •
Heating Bath Circulators (Combined)
- Clinical chemistry and analytics / external temperature control application for measuring cells, photometers, refractometers, polarimete rs, rotary viscometers.
Refrigerated & Heating Bath Circulators (Combined)
- Routine laboratory temperature applications / external temperature control application for measuring cells, photometers, refractometers, polarimeters, viscometers, fermenters, electrophoresis chambers, chromatography columns, rotary evaporators, rheometers.
* For general purpose use and storage.
10 Operating features for BW-B (Analog types)
• +7℃ above room temperature to 100℃. • On / Off temperature control. • Over -temperature limit, alarm indicator. • Analog dialed indication with fine adjustment.
Operating features for BW-H (Digital & Dual types)
• +5℃ above room temperature to 100℃. • PID temperature control. • Over-temperature limit, alarm indicator. • Digital LED displays temperature readouts and setpoint to
0.1℃ or 1℃.
Constructional features • Low-profile baths with front slope-panel controls provide an
easier access and makes it safer.
• Additional inner circulating system by equipped agitator. (BW-H series)
• Dual bath models feature individually programmable temperature controlled chambers. (BW-H series)
• Various accessories - gable and flat covers, test tube and spring wire racks, half-shelf adjusters etc. (optional)
* All accessories for dual baths (BW-H series) refer to BW-H / B series acces-sories options per each bath size.
(Ex. Each gable cover for BW-0510H may be used to cover BW-05H / B and the other cover for BW-10H / B)
BW-10B with test tube rack
BW-10H with gable cover
BW-0510H with open-rings cover
Optional Accessories • Transparent polypropylene gable / Stainless steel flat /
Open-rings covers.• Test tube racks, Spring wire racks, Half-shelf adjusters.
see page 20-21
Economical water bath series with complete temperature maintenance!
Especially BW-B/ H series has a patented agitating system that makes bettertemperature stability. A wide range of choice from analog or digital control, even mix & match sizes of dual bath models.
Baths & CirculatorsHeating Baths (Economic)
11
Baths & CirculatorsHeating Baths (Economic)
Specifications & Ordering Informations Analog types
Model BW-05B BW-10B BW-20BBath volume (L / cu ft) 3.5 / 0.1 11.5 / 0.4 20 / 0.7Working Temperature Range (℃ / ℉) Amb. +7 to 100 / Amb. +12.6 to 212Temperature Stability 1) (±℃ / ℉) 0.5 / 0.9
Dimensions
Bath opening / depth(W×L, D) (mm / inch)
240×136, 115 /9.4×5.4, 4.5
300×240, 165 /11.8×9.5, 6.5
498×300, 165 /19.6×11.8, 6.5
Overall(W×L×H, H) (mm / inch)
303×242×245 /11.9×9.5×9.6
357×330×290 /14.1×13.0×11.4
564×392×290 /22.2×15.4×11.6
Net weight (kg / lbs) 6.5 / 14.3 10.0 / 22.0 18.5 / 40.8Electrical Requirements (230V) 60Hz, 3.0A 50Hz, 3.0A 60Hz, 4.3A 50Hz, 4.3A 60Hz, 8.7A 560Hz, 8.7ACat. No. AAH46011K AAH46012K AAH46021K AAH46022K AAH46031K AAH46032KElectrical Requirements (120V) 60Hz, 5.8A 60Hz, 8.3A 60Hz, 8.3ACat. No. AAH46013U AAH46023U AAH46033U
1) Technical data. (according to DIN 12876)
Specifications & Ordering Informations Digital types
Model BW-05H BW-10H BW-20HBath volume (L / cu ft) 3.5 / 0.1 11.5 / 0.4 20 / 0.7Working Temperature Range (℃ / ℉) Amb. +5 to 100 / Amb. +9 to 212Temperature Stability 1) (±℃ / ℉) ±0.1 / 0.18
Dimensions
Bath opening / depth(W×L, D) (mm / inch)
240×136, 150/ 9.4×5.4, 5.9
300×240, 200/ 11.8×9.5, 7.9
498×300, 200/ 19.6×11.8, 7.9
Overall(W×L×H) (mm / inch)
307×216×266/ 12.08×8.5×10.47
364×316×318/ 14.33×14.44×12.5
564×372×318/ 22.2×14.64×12.51
Net weight (kg / lbs) 6.5 / 14.3 9.5 / 21.0 15.5 / 34.2Electrical Requirements (230V, 50 / 60Hz) 3.0A 4.3A 8.7ACat. No. AAH45115K AAH45125K AAH45135KElectrical Requirements (120V, 60Hz) 5.8A 8.3A 8.3ACat. No. AAH45113U AAH45123U AAH45133U
1) Technical dad (according to DIN 12876)
Specifications & Ordering Informations Dual types
Model BW-0505H BW-0510H BW-1010H BW-1020HBath volume (L / cu ft) 3.5 & 3.5 / 0.1 & 0.1 3.5 & 11.5 / 0.1 &0.4 11.5 & 11.5 / 0.4 & 0.4 11.5 & 20.0 / 0.4 & 0.7Working Temperature Range (℃ / ℉) Amb. +5 to 100 / Amb. +9 to 212Temperature Stability 1) (±℃ / ℉) ±0.1 / 0.18
Dimensions
Bath opening / depth(W×L, D & W×L, D) (mm / inch)
240×136, 150Per chamber
240×136, 150 & 300×240, 200
300×240, 200Per chamber
300×240, 200 & 498×300, 200
9.4×5.4, 5.9Per chamber
9.4×5.4, 5.9 & 11.8×9.5, 7.9
11.8×9.5, 7.9Per chamber
11.8×9.5, 7.9 & 19.6×11.8, 7.9
Overall(W×L, D & W×L, D) (mm / inch)
590×200×265.4 /23.22×7.8×10.45
544×300×317.6 /21.41×11.8×12.5
706×300×317.6 /27.79×11.8×12.5
844×356×317.6 /33.22×14.64×12.5
Net weight (kg / lbs) 9.7 / 21.3 12.4 / 27.3 14 .0 / 30.8 17.6 / 38.7Electrical Requirements (230V, 50 / 60Hz) 3.0 & 3.0A 3.0 & 4.3A 4.3A & 4.3A 4.3A & 8.7ACat. No. AAH47115K AAH47125K AAH47135K AAH47145KElectrical Requirements (120V, 60Hz) 5.8A & 5.8A 5.8A & 8.3A 8.3A & 8.3A 8.3A & 8.3ACat. No. AAH47113U AAH47123U AAH47133U AAH47143U
1) Technical dad [according to Din 12876]
12
Specifications & Ordering Informations
Model BW-05G BW-10G BW-20GBath volume (L / cu ft) 5 / 0.2 10 / 0.4 20 / 0.7Working Temperature Range (℃ / ℉) Amb. +5 to 100 / Amb. +9 to 212Temperature Stability 1) (±℃ / ℉) 0.2 / 0.36
Dimensions
Bath opening / depth(W×L, D) (mm / inch)
231×150, 160/ 9.1×5.9, 6.3
285×211, 180/ 11.2×8.3, 7.1
345×290, 200/ 13.6×11.4, 7.9
Overall / with gable cover(W×L×H) (mm / inch)
355×260×334/ 14.0×10.2×13.1
410×311×354/ 16.1×12.2×14.0
471×390×374/ 18.5×15.4×14.7
Net weight (kg / lbs) 10.0 / 22.0 14.0 / 31.0 18.0 / 40.0Electrical Requirements (230V, 50 / 60Hz) 3.0A 4.4A 8.7ACat. No. AAH41405K AAH41415K AAH41425KElectrical Requirements (120V, 50 / 60Hz) 5.8A 8.3A 8.3ACat. No. AAH41406U AAH41416U AAH41426U
1) Technical data (according to DIN 12880)
Baths & CirculatorsHeating Baths
Excellent temperature performance heating water baths for general-purpose use. BW-G series features Microprocessor PID controls to guarantee exceptional temperature Variation and exclusive timer, programming function for critical research, quality control and regulatory testing!
Operating features • +5℃ above room temperature to 100℃. • Microprocess PID control / Auto-tuning / Calibration. • Digital timer: 1 min to 99 hr 59 min, delayed ON / OFF. • Over-temperature limiter and low fluid level protection. • 3 different temperature values memorable without auto-tuning. • Digital LED display (0.1℃ resolution) with splash-proof keypads.
Constructional features • Stainless steel bath allows to use with water or other bath fluids,
such as silicone fluids.
• User-friendly low-profile baths design with easy-to-use digital controller with 2 display.
• Dry-running protection; automated heating element cut-off and audible and visual warning.
• Bottom baffle plate screens heater and sensor to protect sample and operators from direct contact.
BW-05G included SUS cover Included Accessories • Stainless steel flat type cover. Optional Accessories • Open-rings covers. see page 20-21 • Test tube racks, Spring wire racks,
Half-shelf adjusters.
13
Reciprocal shaking heating baths.
BS series features a more accurate rapid shaking thanks to the noiseless and anti-vibration Brushless DC motor. The constant temperature performance keeps samples incubated, ideal for DNA, tissue, or cell culture applications.
Shaking & Heating Baths
Specifications & Ordering Informations
Model BS-06 BS-11 BS-21 BS-31Bath volume (L / cu ft) 17.0 / 0.6 25.0 / 0.9 37.0 / 1.3 55.0 / 1.9Working Temperature Range (℃ / ℉) Amb. +5 to 100 / Amb. +9 to 212Temperature Stability 1) (±℃ / ℉) 0.2 / 0.36Shaking system
Motion / Speed range (RPM) Reciprocating / 20 to 180Recip stroke length (mm / inch) 25, 30, 35 / 1.0, 1.2, 1.4 Available - Standard 30 / 1.2
Dimensions
Bath opening /depth (W×L, D) (mm / inch)
109×243, 235/ 4.3×9.6, 9.3
229×243, 235/ 9.0×9.6, 9.3
389×243, 235/ 15.3×9.6, 9.3
670×350, 235/ 26.4×13.8, 9.3
Overall (W×L×H) (mm / inch)
430×440×355/ 16.9×17.3×14.0
550×440×355/ 21.7×17.3×14.0
710×440×355/ 28.0×17.3×14.3
860×490×355/ 33.9×19.3×14.0
Net weight (kg / lbs) 3.7A 4.6A 8.9A 8.9AElectrical Requirements (230V, 60Hz) 3.0 & 3.0A 3.0 & 4.3A 4.3A & 4.3A 4.3A & 8.7ACat. No. AAH44061K AAH44111K AAH44211K AAH44311KElectrical Requirements (230V, 50Hz) 3.7A 4.6A 8.9A 8.9ACat. No. AAH44062K AAH44112K AAH44212K AAH44312KElectrical Requirements (120V, 60Hz) 7.1A 8.8A
- -Cat. No. AAH44063U AAH44133U
※ BS-21,31 are provided ONLY for 230 voltage.1) Technical data. (according to DIN 12876)
Operating features • +5℃ above room temperature to 100℃. • Microprocess PID control / built-in Calibration. • Digital timer: 1 min to 99 hr 59 min, delayed ON / OFF. • Independent over-temperature limiter. • Digital LED display (0.1℃ / 1 rpm resolution) with splash-proof keypads.
Constructional features • Shaker mechanism has its own control key, so the unit can be used
as constant temperature baths.
• Gently start shaking to minimize shock to the test samples.
• Multi-LED display for adjusting actual value, setpoint temperatures and shaking frequency.
• Baffle plate screens circulator, heater, and sensor to minimize turbulence in the bath fluid and to protect the sample and user from direct contact with the heating element.
• Shaking carriage is removable and can be assembled outside of the bath; no direct contact with the bath fluid.
• Included bath cover prevents liquid losses, the gable type roof ensures no-dripping into the test samples directly.
• Included SUS 304 spring wire rack consists double column for various setting of glassware.
BS-31 included gable cover and spring wire rack Included Accessories • Stainless steel gable type cover. • Spring wire racks. Optional Accessories • Universal platform, Dedicated platform,
Flask clamps. see page 19 • Test tube racks.
Baths & Circulators
14
Viscometer Heating Baths
Specifications & Ordering Informations Model VB-25G VB-40G
Bath volume (L / cu ft) 25.0 / 0.9 40.0 / 1.4Working Temperature Range 2) (℃ / ℉) Amb. +5 to 150 / Amb. +9 to 302Temperature Stability 1) (±℃ / ℉) 0.05 / 0.09 0.1 / 0.18
Dimensions
Bath opening / depth (W×L, D) (mm / inch) 145×265, 368 / 5.7×10.4, 14.5 295×265, 368 / 11.6×10.4, 14.5Cover lids / Hole for thermometer (mm) 5ea / Ø51.0, 1ea / Ø12.6 8ea / Ø51.0, 1ea / Ø12.6Overall (W×L×H) (mm / inch) 492×374×547 / 19.4×14.7×21.5 642×374×547 / 25.3×14.7×21.5Net weight (kg / lbs) 28.0 / 61.7 37.0 / 81.6
Electrical Requirements (230V) 60Hz, 13.0A 50Hz, 13.0A 60Hz, 13.0A 50Hz, 13.0ACat. No. AAH43301K AAH43302K AAH43401K AAH43402K
* VB-25G, 40G series are provided ONLY for 230 voltage.1) Technical data. (according to DIN 12876)2) If you want to operate the unit below Amb. +5℃ (Amb. +9℉), the optional cooling circulator must be used with.
In that case, the temperature range can be from +10℃ (+50℉). Ordering information - refer to P.17
VB-G series maintains higher temperature stability and excellent visibility for kinematic viscosity measurement using glass capillary viscometers.
Ultra precise temperature control with excellent visibility!
Operating features • +5℃ Above room temperature to 150℃. • Microprocess PID control / Auto-tuning / Calibration. • Digital timer: 1 min to 99 hr 59 min, delayed ON / OFF. • Over-temperature limiter and low fluid level protection. • Conveniently preset 3 most commonly used temperature settings • Select between Celsius and Fahrenheit. • Digital LED display with splash-proof keypads.
(0.01℃ resolution at 0~99.9℃ / 0.1℃ resolution at 100~150℃)
• RS-232 interface available.
Constructional features • Double tempered safety glass windows in front and rear well
ensures excellent visibility.
• Baffle plate screens circulator, heater, and sensor to minimize turbulence in the bath fluid and to protect samples and users from direct contact with the heating element.
• A vane type stirrer makes powerful circulation for creating an optimal temperature variation.
• Included stainless steel cooling coil allows to work at temperatures below or slightly above ambient.
(Use of optional cooling circulator allows to work at temperatures from 10℃ / 50℉)
• Ø51.0mm holes for suspending glass capillary viscometers tubes and a Ø12.6mm hole for thermometer.
VB-40G included SUS coversIncluded Accessories • Stainless steel covers for holes in the top. • Cooling coil.Optional Accessories • Tube holders for 2 openings viscometer
glass tube. (Max. 5 holders for VB-25G / Max. 8 holders for VB-40G)
see page 21 • Cooling circulators.
Baths & Circulators
15
Heating Bath Circulators
External and internal circulating with powerful pumping capacity.
CW-G series is designed for controlling temperature in external instruments, or for immersion purposes. Pump has five adjustable pressure stages.
Operating features • +5℃ above room temperature to 150℃. • Microprocessor PID control / Auto-tuning / Calibration. • Digital timer: 1 min to 99 hr 59 min, delayed ON / OFF. • Over-temperature limit and low fluid level protection. • Conveniently preset 3 most commonly used temperature settings,
without auto-tuning. • Digital LED display (0.1℃ resolution) with splash-proof keypads. • RS-232 interface available.
Constructional features • Variable-speed pump for liquid viscosity for accurate, stable, and
efficient temperature management. (1 to 3 steps of pump for internal circulation / 4 and 5 steps for external circulation)
• Powerful pressure and suction pumps provide contrast pressure and flow rate throughout the whole temperature range.
• Baffle plate screens circulator, heater, and sensor to minimize shaking bath fluids and protect sample and operators from direct contact.
• Dry-running protection; automated heating element cut-off and audible and visual warning.
• Seamless stainless steel tank with a reservoir drain that resists corrosion and make cleaning easy.
• Space saving design uses minimal bench space.
CW-05G included SUS coversIncluded Accessories • Stainless steel flat type cover. • One 30cm (1 ft) length and Ø12mm of
silicone rubber tubing.Optional Accessories • Suction function for pump.
see page 20-21 • Test tube racks, Spring wire racks.
Specifications & Ordering Informations Model CW-05G CW-10G CW-20G CW-30G
Bath volume (L / cu ft) 5.0 / 0.2 10.0 / 0.4 20.0 / 0.7 30.0 / 1.1Working Temperature Range 2) (℃ / ℉) Amb. +5 to 150 / Amb. +9 to 302Temperature Stability 1) (±℃ / ℉) 0.05 / 0.09 0.05 / 0.09 0.1 / 0.18 0.1 / 0.18
PumpMax. pressure, max. flow rate 5.9 PSI (406.8 millibar), 7.4 gallons / minute (28.0 liters / minute)
Max. suction flow rate 2.6 gallons / minute (10.0 liters / minute)
Dimensions
Bath opening / depth(W×L, D) (mm / inch)
150×99, 160/ 5.9×3.9, 6.3
211×154, 180/ 8.3×6.1, 7.1
290×214, 200/ 11.4×8.4, 7.9
300×264, 230/ 11.8×10.4, 9.0
Overall(W×L×H) (mm / inch)
220×395×424/ 8.7×15.6×16.7
281×450×444/ 11.1×17.7×17.5
360×510×464/ 14.2×20.1×18.3
370×560×494/ 14.6×22.0×19.4
Net weight (kg / lbs) 12.5 / 27.6 15.0 / 33.0 17.5 / 38.6 19.5 / 43.0Electrical Requirements (230V, 50 / 60 Hz) 4.5A 6.7A 8.8A 8.8ACat. No. AAH52305K AAH52315K AAH52325K AAH52335KElectrical Requirements (120V, 50 / 60 Hz) 8.6A 8.6A 8.6A 8.6ACat. No. AAH52306U AAH52316U AAH52326U AAH52336U
1) Technical data. (according to DIN 12876)2) If you operate the unit in 1 to 3 steps of pump, the temperature range can be from Amb. +5℃ but in 4 and 5 steps, the range will be from Amb. +15℃.
Baths & Circulators
16
Refrigerated & Heating Bath Circulators
Rapid heating and cooling throughout the entire temperature range!RW-G series has powerful circulation pump for external and internal circulating. The temperatures can be down to maximum -35℃ that maintain and control accurate low temperatures for use with Refractometers and Viscometers.
Operating features • -25 to 150 for RW-25G / -35 to 150 for RW-40G. • Microprocessor PID control / Auto-tuning / Calibration. • Digital timer: 1 min to 99 hr 59 min, delayed ON / OFF. • Over-temperature limit and low fluid level protection. • Conveniently preset 3most commonly used temperature settings. • Digital LED display (0.1 resolution) with splash-proof keypads. • RS-232 interface available.
Constructional features • Turbulence reduced do to five-speed duplex pump and built-in
cooling coil let you use in an open or closed bath environment. (1 to 3 steps of pump for internal circulation / 4 and 5 steps for external circulation)
• Baffle plate screens circulator, heater, and sensor to minimize turbulence in the bath fluids and to protect the samples and user from direct contact with the heating or cooling element.
• Dry-running protection; automated heating element cut-off and audible and visual warning.
• Seamless stainless steel tank with a reservoir drain that resists corrosion and make cleaning easy.
• Use CFC-free refrigerant R-134A, R-404A and double service valve to prevent the leakage of refrigerant.
• Quick-release front grille for easy condenser cleaning and space saving design uses minimal bench space.
RW-0525G included SUS coversIncluded Accessories • Stainless steel flat type cover. • One 30 cm (1 ft) length and Ø12 mm of
silicone rubber tubing.Optional Accessories • Additional suction function.
see page 20-21 • Test tube racks, Spring wire racks. * Applicable for CW-G, RW-25G, RW-40G series.* Bath fluid : Water (on the normal temperature)
Baths & Circulators
17
Refrigerated & Heating Bath CirculatorsBaths & Circulators
Specifications & Ordering Informations RW-25G models for temperature range of -25℃ to 150℃
Model RW-0525G RW-1025G RW-2025G RW-3025GBath volume (L / cu ft) 5.0 / 0.2 10.0 / 0.4 20.0 / 0.7 30.0 / 1.1Working Temperature Range 2) (℃ / ℉) -25 to 150 / -13 to 302Temperature Stability 1) (±℃ / ℉) 0.05 / 0.09 0.05 / 0.09 0.05 / 0.09 0.08 / 0.14
Coolingcapacity
at -20℃ (-4℉), W 30 50 260 390at 0℃ (+32℉), W 230 250 410 570at +20℃ (68℉), W 320 380 560 680Refrigerator 1 / 3 LBP, R-134A 1 / 3 LBP, R-134A 1 / 2 LBP, R-404A 3 / 4 LBP, R-404A
PumpMax. pressure, max. flow rate 5.9 PSI (406.8 millibar), 7.4 gallons / minute (28.0 liters / minute)
Max. suction flow rate 3) 2.6 gallons / minute (10.0 liters / minute)
Dimensions
Bath opening /depth(W×L, D) (mm / inch)
150×99, 160/ 5.9×3.9, 6.3
211×154, 180/ 8.3×6.1, 7.1
290×214, 200/ 11.4×8.4, 7.9
300×264, 230/ 11.8×10.4, 9.0
Overall(W×L×H) (mm / inch)
302×438×690/ 11.9×17.2×27.2
360×490×780/ 14.2×19.3×30.7
380×560×825/ 15.0×22.0×32.5
440×620×895/ 17.3×24.4×35.2
Net weight (kg / lbs) 37.0 / 81.6 44.0 / 97.0 60.0 / 132.2 7.0 / 147.7Electrical Requirements (230V, 60Hz) 7.0A 9.2A 12.8A 13.8ACat. No. AAH57001K AAH57011K AAH57021K AAH57031KElectrical Requirements (230V, 50Hz) 7.0A 9.2A 12.8A 13.8ACat. No. AAH57002K AAH57012K AAH57022K AAH57032KElectrical Requirements (120V, 60Hz) 12.6A 12.6A
- -Cat. No. AAH57003U AAH57013U
* RW-2025G, 3025G are provided ONLY for 230 voltage. 1) Technical data. (according to DIN 12876)2) The cooling capacity is measured on a 230V / 50Hz electrical condition.3) The additional suction function is optional.
Specifications & Ordering Informations RW-40G models for temperature range of -35℃ to 150℃
Model RW-0540G RW-1040G RW-2040G RW-3040GBath volume (L / cu ft) 5.0 / 0.2 10.0 / 0.4 20.0 / 0.7 30.0 / 1.1Working Temperature Range 2) (℃ / ℉) -35 to 150 / -31 to 302Temperature Stability 1) (±℃ / ℉) 0.05 / 0.09 0.05 / 0.09 0.05 / 0.09 0.08 / 0.14
Coolingcapacity
at -20℃ (-4℉), W 80 150 400 440 at 0℃ (+32℉), W 150 330 660 700 at +20℃ (68℉), W 280 450 800 880Refrigerator 1 / 2 LBP, R-404A 1 / 2 LBP, R-404A 3 / 4 LBP, R-404A 1 LBP, R-404A
PumpMax. pressure, max. flow rate 5.9 PSI (406.8 millibar), 7.4 gallons / minute (28.0 liters / minute)
Max. suction flow rate 3) 2.6 gallons / minute (10.0 liters / minute)
Dimensions
Bath opening /depth(W×L, D) (mm / inch)
150×99, 160/ 5.9×3.9, 6.3
211×154, 180/ 8.3×6.1, 7.1
290×214, 200/ 11.4×8.4, 7.9
300×264, 230/ 11.8×10.4, 9.0
Overall(W×L×H) (mm / inch)
302×438×690/ 11.9×17.2×27.2
360×490×780/ 14.2×19.3×30.7
380×560×825/ 15.0×22.0×32.5
440×620×895/ 17.3×24.4×35.2
Net weight (kg / lbs) 38.0 / 83.8 44.0 / 97.0 60.0 / 132.2 67.0 / 147.7Electrical Requirements (230V, 60Hz) 8.5A 10.7A 13.8A 14.8ACat. No. AAH57101K AAH57111K AAH57121K AAH57131KElectrical Requirements (230V, 50Hz) 8.5A 10.7A 13.8A 14.8ACat. No. AAH57102K AAH57112K AAH57122K AAH57132K
* RW-0540G, 1040G, 2040G, 3040G series are provided ONLY for 230 voltage.1) Technical data. (according to DIN 12876)2) The cooling capacity is measured on a 230V / 50Hz electrical condition. 3) The additional suction function is optional.
18 Features
• The temperature is indicated by LED digits. • Glass traps can be connected. • Over Current Breaker. • 2 glass traps comes standard with the equipment. • Condenser can be cleaned easily by opening front cover. • Realized constructive precision, little noise, small size of the body. • Dissolving system for ice or solid matter stuck on the bath. • Durable Stainless Steel Bath. • Transparent acrylic lid with glass trap to check condensate level in
the trap.
Digital temperature display.Effective moisture capture.Useful for exceptional cooling system.
Specifications
Specifications CTB - 10Temperature Range (℃ / ℉) Down to -40 / -40
Material
Bath external Stainless steel, 1.2t, double painted & bakedBath up desk Stainless steel, 1.5tInsulation Polyurethane foam (30mm)
Refrigerator 1 / 2 HP, R-404A (LBP)
Dimensions
Volume (L / cu ft) 4.8 / 0.17Bath (Ø×H, mm) Dia, 210×204 / 8.3×8Overall (W×D×H) (mm / inch) 360×465×555 / 14.1×18.3×21.9Net weight (kg / lbs) 46 / 101.4
Electrical Requirements 230V, 60HzCat. No. AAH62011K
Electrical Requirements 230V, 50HzCat. No. AAH62012K
Standard Accessories
Cold Trap Bath
CTB-10Included Accessories • U-type glass traps 2EA.
Baths & Circulators
Model Description Cat. No.Related accessory U-type Glass Trap AAA62501
19
Accessories & Options
for Shaking & Heating Baths
Universal platforms Flask clamps Dedicated platforms Test tube racks
Baths & Circulators
Universal platforms & Flask clamps The universal platforms provide flexibility for mixing different size test tubes and glassware on a single platform. Flask clamps vailable with
different size clamps for Erlenmeyer flasks. (only for BS series)
BS-06 BS-11 BS-21 BS-31Universal platform Cat. No. AAA44521 AAA44522 AAA44523 AAA44524
Max. mountable flask clamps*Cat. No. Erlenmeyer flask sizeAAA23550 for 50mL 9 12 20 32AAA23551 for 100mL 3 9 15 24AAA23552 for 250ml 2 4 8 12AAA23556 for 300mL 2 4 8 12AAA23553 for 500ml 2 4 6 12AAA23554 for 1L 1 2 4 6AAA23555 for 2L ◊ - 1 2 3AAA23557 for 2.8L ◊ - 1 1 2
◊ 2 and 2.8L flasks must be used with opening the bath cover by height problem.* Flask clamps for Universal platform are each sold separately.
Dedicated platforms If using a single flask size only, the dedicated platforms provided below are maximum capacity of clamps for each platform size; Comes with
clamps installed. Provided are standard clamps with volume sizes of 250mL and 500mL, but it is possible to purchase other size clamps. (only for BS series)
Cat. No. DescriptionAAA44531 universal platform for BS-06 with 250mL flask clamps 2ea onAAA44532 universal platform for BS-06 with 500mL flask clamps 2ea onAAA44541 universal platform for BS-11 with 250mL flask clamps 4ea onAAA44542 universal platform for BS-11 with 500mL flask clamps 4ea onAAA44551 universal platform for BS-21 with 250mL flask clamps 8ea onAAA44552 universal platform for BS-21 with 500mL flask clamps 6ea onAAA44561 universal platform for BS-31 with 250mL flask clamps 12ea onAAA44562 universal platform for BS-31 with 500mL flask clamps 12ea on
※ A dedicated platform is sold with setting each max. mountable amount of flask clamps on.
Test tube racks Highly durable stainless steel racks with adjustable angle and tube height support. No need for any other base plates to use the test tube
racks, simply release and mount racks directly.
Cat. No. Description Insert capacity of racks*AAA44581 for 86 test tubes 8mm dia. (0.3˝)
BS-061EA
BS-112EA
BS-213EA
BS-314EA
AAA44582 for 86 test tubes 10mm dia. (0.4˝)
AAA44583 for 58 test tubes 12mm dia. (0.5˝)
AAA44585 for 32 test tubes 16mm dia. (0.6˝)
AAA44586 for 19 test tubes 25mm dia. (1.0˝)
* No declination※ In addition to providing standard accessories, we will manufacture customized accessories to meet your specific requirements. Contact us for details.
20
Accessories & Options
Transparent polypropylene gable covers Stainless steel flat covers Open-rings Covers
for Baths & Bath Circulators
Baths & Circulators
Transparent polypropylene gable type covers Prevent liquid loss due to evaporation, protect samples from contamination. Made of transparent polypropylene material to observe the
samples and gable type roof accommodates glassware of varying height. (only for BW-H/ B series)
Cat. No. Description Suitable forAAA45531 Transparent polypropylene gable type BW-05H / BW-05BAAA45532 Transparent polypropylene gable type BW-10H / BW-10BAAA45533 Transparent polypropylene gable type BW-20H / BW-20B
Stainless steel flat type covers Made of stainless steel to prevent corrosion and rust. (only for BW-H/ B series)
Cat. No. Description Suitable forAAA45541 Stainless steel flat type BW-05H / BW-05BAAA45542 Stainless steel flat type BW-10H / BW-05BAAA45543 Stainless steel flat type BW-20H / BW-05B
Open-rings covers Beakers or Erlenmeyer flasks can be placed directly onto the perforated stainless steel half-shelf adjuster or water tank bottom. Adjustable
rings size for each glassware to minimize liquid losses due to evaporation. (only for BW-H/ B and BW-G series)
Cat. No. Description Suitable forAAA45521 with 2 openings 80mm dia. (3.1˝) BW-05H / BW-05BAAA45524 with 1 opening 110mm dia. (4.3˝)AAA45522 with 4 openings 80mm dia. (3.1˝)
BW-10H / BW-10BAAA45525 with 2 openings 110mm dia. (4.3˝)AAA45526 with 1 opening 185mm dia. (7.3˝)AAA45523 with 8 openings 80mm dia. (3.1˝)
BW-20H / BW-20BAAA45527 with 6 openings 110mm dia. (4.3˝)AAA45528 with 2 openings 185mm dia. (7.3˝)AAA41561 with 2 openings 80mm dia. (3.1˝) BW-05GAAA41564 with 1 opening 110mm dia. (4.3˝)AAA41562 with 4 openings 80mm dia. (3.1˝)
BW-10GAAA41565 with 2 openings 110mm dia. (4.3˝)AAA41566 with 1 opening 185mm dia. (7.3˝)AAA41563 with 6 openings 80mm dia. (3.1˝)
BW-20GAAA41567 with 4 openings 110mm dia. (4.3˝)AAA41568 with 1 opening 185mm dia. (7.3˝)
Test tube racks Highly durable stainless steel racks with adjustable angle and tube height support. Do not need any other base plates to use it, simply release
and mount racks directly.
Cat. No. Description Insert capacity of racks*AAA44581 for 86 test tubes 8mm dia. (0.3˝)AAA44582 for 86 test tubes 10mm dia. (0.4˝)AAA44583 for 58 test tubes 12mm dia. (0.5˝)AAA44585 for 32 test tubes 16mm dia. (0.6˝)AAA44586 for 19 test tubes 25mm dia. (1.0˝)AAA41531 for 50 test tubes 8mm dia. (0.3˝)AAA41532 for 50 test tubes 10mm dia. (0.4˝)AAA41533 for 33 test tubes 12mm dia. (0.5˝)AAA41535 for 16 test tubes 16mm dia. (0.6˝)AAA41539 for 10 test tubes 25mm dia. (1.0˝)AAA45551 for 176 test tubes 8mm dia. (0.3˝)AAA45552 for 176 test tubes 10mm dia. (0.4˝)AAA45554 for 84 test tubes 12mm dia. (0.5˝)AAA45556 for 68 test tubes 16mm dia. (0.6˝)AAA45561 for 33 test tubes 25mm dia. (1.0˝)
BW-05HBW-05B
BW-10GCW-20G, 30GRW-2025G, 2040G, 3025G, 3040G
BW-20G
1EA 2EA 3EA
BW-05GCW-10G
RW-1025G, 1040G
1EA
BW-10HBW-10B
BW-20HBW-20B
1EA 2EA
21
Accessories & Options
Spring wire racks Half-shelf adjusters Suction function for pumps
for Baths & Bath Circulators
Baths & Circulators
Spring wire racks Ideal for holding a wide variety of tubes, flasks, and other glassware.
All components are made of stainless steel. (for all models)
Cat. No. Suitable forAAA45502 BW-10H / BW-10BAAA45503 BW-20H / BW-20BAAA41502 BW-10GAAA41503 BW-20GAAA51522 CW-20G / RW-2025G, 2040GAAA51523 CW-30G / RW-3025G, 3040G
Viscometer tube holders Holders for 2 openings viscometer glass tube, made of thermal
endurance material:Bakelite. (only for VB series)
Cat. No. Suitable for
AAA43501 VB-25G (need Max. 5 holders)VB-40G (need Max. 8 holders)
Half-shelf adjusters Stainless steel perforated sample tray shelf with adjustable height support prevents leaks and guards against rust and contamination.
(only for BW-H / B and BW-G series)
Cat. No. Suitable forAAA45511 BW-05H / BW-05BAAA45512 BW-10H / BW-10BAAA45513 BW-20H / BW-20BAAA41551 BW-05GAAA41552 BW-10GAAA41553 BW-20G
for Viscometer Heating Baths
Cooling circulators for visco baths The temperature range of viscometer baths series is from +10 (+50℉) when be used with the additional cooling circulators. (only for VB series)
Cat. No. Suitable for Cooling circulators *AAH57011K VB-25G (230V, 60Hz) RW-1025G (230V, 60Hz)
AAH57012K VB-25G (230V, 50Hz) RW-1025G (230V, 50Hz)
AAH57021K VB-40G (230V, 60Hz) RW-2025G (230V, 60Hz)
AAH57022K VB-40G (230V, 50Hz) RW-2025G (230V, 50Hz)
* Refer to P.16-17 for more specific information of the cooling circulators.
Suction function for pumps* Additional suction function for powerful external / internal circulating.
Maximum suction flow rate is 10.0 liters per minute. (only for CW-G and RW-G series)
Cat. No. Suitable for52503 CW-05G / RW-0525G, 0540G52513 CW-10G / RW-1025G, 1040G52523 CW-20G / RW-2025G, 2040G52533 CW-30G / RW-3025G, 3040G
* The additional suction function is needed to have a prior request.
Viscometer tube holders
Cubic Vacuum Desiccators.Round Vacuum Desiccators.
Desiccators
Constructional features • Fitted with an airtight silicon gasket to maintain
a tight vacuum seal without the use of any grease.
• Highly transparent PC (Polycarbonate) strong, great for clear viewing of samples, non-corrosive, easy to clean and maintain.
• The basic component of the drying agent tray and desiccant allows the desiccators to be used in various experiments that involve desiccation.
• Convenient 2-Way stopcock provides a cons-istent and uniformed release of vacuum during operation.
• O-ring and additional exclusively developed “Locking Clip” provide an air tight seal at any vacuum or atmospheric conditions.
(only VDR Series)
• Flange Lock holds the base and top together during non vacuum conditions. (only VDR Series)
• Detachable analog vacuum gauge, fitted at the center of the lid. (optional only VDR Series)
• The heavy-duty desiccators are durably con-structed. (only VDC Series)
• Included are 4 ports for attachment of other vacuum gauges or stopcocks. (only VDC Series)
• To maximize laboratory space the desiccators can be stacked 5 high
(max stacking limit: 5 units - only VDC Series)
Selection Guide
Description Internal volume (L / cu ft) Vacuum range (MPa) Body MaterialCubic type VDC-31 35 / 1.2 1.13 × 10- 4 Mpa (Analog) PC (Polycarbonate)
Round typeVDR-20 (20G) 6 / 0.2
1.13 × 10- 4 Mpa (Analog) PC (Polycarbonate)VDR-25 (25G) 10 / 0.4VDR-30 (30G) 20 / 0.7
* VDR-G Type is with gauge.
23
Round & Cubic Vacuum DesiccatorsDesiccators
Offer reliable vacuum condition: Desiccators holds -0.1 Mpa for 72 hours.
Fitted with an airtight silicon gasket to maintain a tight vacuum seal without the use of any grease.: for safeguards samples, electronics, other high-value items.
Durable Vacuum Desiccators (Transparent models)
Specifications & Ordering Informations Cubic Vacuum Desiccators.
MODEL VDC-31Internal volume (L / cu ft) 35.0 / 1.2Vacuum range (MPa) 0 ~ -0.1 (Analog)
Nozzle (mm / inch, Ø) 9.5 / 0.37Max. permissible vacuum (Bodies) 1.13×10 -4 MPaMax. load (kg / lbs) / for shelf 5.0 / 11.0Number of shelves (included / max.) 3 / 5
Material
Bodies PC (Polycarbonate)
Perforated sample tray PC (Polycarbonate)
Drying agent tray / Locker PP (Polypropylene)
Vacuum seal Silicone Rubber
Dimensions(W×H)
Internal (mm / inch) 355×375×345 / 14.0×14.8×13.6Exterior (mm / inch) 418×398×381 / 16.5×15.7×15.0
Net weight (kg / lbs) 11.5 / 25.4Cat. No. AAAD4011
Round Vacuum Desiccators.
MODEL VDR-20 (20G) VDR-25 (25G) VDR-30 (30G)
Internal volume (L / cu ft) 6.0 / 0.2 10.0 / 0.4 20.0 / 0.7Vacuum range (MPa) 0 ~ -0.1 (Analog)
Nozzle (mm / inch, Ø) 9.5 / 0.37Max. permissible vacuum (Bodies) 1.13×10 -4 MPa
Materiallid / Bottom PC (Polycarbonate)
Tray, Locker PP (Polypropylene)
Vacuum seal Silicone Rubber
Dimensions(W×H)
Exterior(mm / inch)
Ø286×279 / Ø11.3×11.0 Ø353×325 / Ø13.9×12.8 Ø427×399 / Ø16.8×15.7 (Ø286×354 / Ø11.3×13.9 ) (Ø353×400 / Ø13.9×15.7) (Ø427×475 / Ø16.8×18.7)
Net weight (kg / lbs)
1.5 / 3.3 2.5 / 5.5 4.2 / 9.3(1.7 / 3.7) (2.6 / 5.7) (4.3 / 9.5)
Cat. No.without gauge AAAD2011 AAAD2111 AAAD2211with gauge (G types) AAAD2021 AAAD2121 AAAD2221
for Cubic & Round Vacuum Desiccators.Cat. No. DescriptionAAAD1501 VDE-501 Drying Agent Tray for VDR-20 Series
AAAD1502 VDE-502 Drying Agent Tray for VDR-25 Series
AAAD1503 VDE-503 Drying Agent Tray for VDR-30 Series
VDC0005 Drying Agent Tray for VDC-31
AAAD1511 VDE-511 Perforated Sample Tray for VDR-20 Series
AAAD1512 VDE-512 Perforated Sample Tray for VDR-25 Series
AAAD1513 VDE-513 Perforated Sample Tray for VDR-30 Series
VDC0003 Perforated Sample Tray for VDC-31
VDR0004 VDR-0001 Silicagel for VDR-20 Series (20g)
VDR0005 VDR-0002 Silicagel for VDR-25, 30 Series (40g)
Cat. No. DescriptionVDR0001 Vacuum Seal for VDR-20 SeriesVDR0002 Vacuum Seal for VDR-25 SeriesVDR0003 Vacuum Seal for VDR-30 SeriesVDC0015 Vacuum Seal for VDC-31VDR0015 Flange Locker for VDR-20 SeriesVDR0016 Flange Locker for VDR-25 SeriesVDR0017 Flange Locker for VDR-30 SeriesEDA4300 Vacuum gauge for VDR SeriesEDA4214 Vacuum gauge for VDC-31AAAD1521 Stopcock for VDR SeriesAAAD1522 Stopcock for VDC-31
Clean Benches.Ductless Fume Hoods.PCR Workstations.UV Sterilization Cabinets.
Fume Hoods
Selection GuideFume Hoods
Description Filter Work Surface Page
Clean BenchesBC-01E
HEPA Filter Stainless Steel #304 26BC-11EBC-21E
Ductless Fume HoodsDLH-01G Optional 6
Different FiltersOptional 6 DifferentWork Surface 30
DLH-11G
PCR WorkstationsPW-01
HEPA Filter Acryl 10 mm / 0.39 inch(Clear type) 34PW-11
PW-21
UV Sterilization CabinetsUVC-01
- Stainless Steel #304 34UVC-11UVC-21
Accessories & OptionsDescription Page
for Clean Benches 29for Ductless Fume Hoods 33for PCR Workstations & UV Sterilization Cabinets 37
General ApplicationsGeneral Applications
Fume Hoods BC-Series PW-Series DLH-Series
Asbestos Handling • •Chemical sampling •Chemical preparationin an electron microscopy or histology laboratory,forensic, and pharmaceutical applications, depending on the solvents used
•
Cosmetic production to photochemical •Dental laboratory •Electronics Inspection / Repair • •Fingerprinting •General Forensics • • •Medical device assembly •Non-biohazardous [Tissue] Culture Maintenance • •
Non-toxic IV Solution Preparation • •Numerous vapor-generating laboratory processes (HPLC preparation and biochemistry protocols can be performed with improved safety and comfort)
•
PCR •Plant Tissue Culture Maintenance • •Powder extraction •QA / QC Testing • • •Slide preparation •Staining with Volatile •Sterile Media Preparation •Syringe filling •Sterile Media Preparation •Tissue Fixation / Staining Preparation • •Touch up painting •Volatile Radiolabeling / Tagging • •Weighing Toxic Powders • •Welding fumes •
* For general purpose use and storage applications.
Technical BenefitsClean benches Ductless fume hoodsSafety functions - 2 separated over- current fuses for user safety. - Toggle switch provided can be selective one of
them. (UV, off, and fluorescent)
- Automated UV lamp switch off when unintended window opening.
- Tempered glass sliding sash window and intercept the UV light for user safety.
- Permanent magnehelic differential pressure gauge displays across the HEPA filter to check the air changes. (optional)
- Using a 99.99% efficient supply HEPA filter.
Ideal construction - Optimum PWM (pulse width modulation) control
performance. - As a blower of large enough capacity is adapted,
sufficient intake flow rate is maintained and noise is reduced.
- Dirt-repellent surface external powder coating.- Light and blower switches are within easy reach
of the user.- Great chemical resistance work surface (#304) with
various organic solvents.
Ideal construction - Front windows part can be seeing through made
by transparent acryl.- Lower Stand mounted fixable casters easy for
moving & fixing. (Optional)- Control Panel : Consist of fluorescent lamp, Fan
Start/Stop, Blower speed controller, alarm, menu and etc.
- Over - current circuit CP (Circuit Protector) for user safety. - Anemometer: Visual for the input air velocity at real
time.- Door Stay : Fixture to fix it when door open at 2 step.
(if it's dropped without backing up, result in damage, and Fixing magnetic enable to open hold it to 1 step-door.)
PCR workstations & UV Sterilization CabinetsIdeal construction - Built-in over-current products for user safety.- Intelligent Digital controller.
(timer, alarm, blower speed (PW-series)) - Pre-filter mounted extends the life of the filters.
(PW-series)- High quality 99.99% efficient supply HEPA filter.- Powerful, uniformly distributed, UV-C.
(average 8,000 hours) - Excellent chemical resistance work surface.
(UVC-series)- Automated UV lamp switch off.
26
Clean Benches
※ Product design subject to change without notice.
BC-11EOptional Accessories •Standwithcaster.
see page 29 •Differentialpressuregauge.
Please visit .comFor further information on Jeio Tech´s Fume Hood products Information is readily available on our website.
Fume Hoods
27
Vertical type laminar flow clean bench!ISO 14644-1 Class 4 air. (formerly Class 10 per Federal Standard 209E)Supply HEPA filter, high efficient for particles beginning at size 0.3micron. Nominal downflow velocity of 0.3m/s. (60fpm)Ergonomic 5 degree sloped front for comfort.
Control panel
Service Fixtures (Optional)
Gas
Vacuum
Air
Filtration features Particle-free ISO 14644-1 Class 4 air
• Particle count in the work area conform to ISO Class 4 conditions (formerly Class 10 per Federal Standard 209E). Supply HEPA filter, 99.99% efficient on particles 0.3 micron.
• Polyester fiber pre-filter that has a minimal pressure loss and 85% arrestance on the A.F.L. test which serves to trap larger particles and increase the life of the main filter.
• Neoprene gaskets ensures that the HEPA filter is airtight to the body unit. ※The HEPA filters life span depending on the test room conditions has a life span about 3 years.
Constructional features Ergonomic design
• Angled front profile is free of protrusions that will not interfere with visibility or obstruct tall users.
• 304 grade stainless steel work surface - Highly durable and rust free work zone, made for easy cleaning.
• Use of tempered glass door to be strong of damage and intercepts the UV light for user safety.
• The door smoothly slides up and down and stops at any height useful for protecting the user when used at a proper level or for easy transportation of experimental apparatuses and equipments into the workspace.
• Right and left both sides also have wide glasses windows for a clear viewing.
• Adjustable blower located by the front blower switch.
Lighting • Electronically ballasted FL lamp is installed on the top center roof inside the hood that
minimizes airflow disturbance and shadows in the work zone, and to relieves eye strain.
• Toggle switch provided can be set up to turn On/Off UV, off, and fluorescent functions, so one can make sure that the user is safely protected from careless switching on UV & fluorescent lamps at the same time.
Clean Bench Airflow Profile • Room air is taken in from the top blower of the bench through a disposable pre-filter.
• The filtered air is first purified by the secondary HEPA filter to confirm to class standards.
• The laminar down-flowing air is supplies from the dual filtering system into the working zone.
• The clean bench work zone easily maintains a high sterile condition due to positive pressure preventing outside contaminants.
• The purified air flows across the work zone in the cabinet in a vertical, unidirectional stream and leaves the main work chamber across the entire open front of the cabinet and in through the slots.
Clean Benches Fume Hoods
28
Dimensions (Model: BC-11E)
Clean Benches Fume Hoods
1. Pre-Filter 2. Blower 3. HEPA Filter 4. UV Lamp 5. Fluorescent Lamps 6. Tempered Glass Side Panel 7. Service Fixture 8. Sliding Front Sash Window 9. Electrical Outlet socket 10. Stainless Steel Grade 304 Work Surface11. Blower Speed Controller 12. Differential pressure gauge
Air flow Diagram
9
10
11
1
2
34
5
8
6
7
12
Specifications & Ordering Informations
Model BC-01E BC-11E BC-21EAir Flow Type Vertical flowAir Volume (Minimum / Maximum) 274 to 914 cmh / 119 to 399 cfmLaminar Airflow Velocity (m / s / fpm) 0.3 / 60Air Cleanliness Within Working Area ISO 14644-1 Class 4, US Federal Standard 209E Class 10
FiltersHEPA Filter Typical efficiency of 99.99% at 0.3㎛ US MIL - STD -282
; Micro glass fiber Media, Particle board, AL separator, Neoprene gaskets
Pre-Filter Polyester fibers with an efficiency of 85% (A·F·I TEST) ; AL frame, Polyester fiber MediaNoise Level Typically < 67dBA at initial Blower speed
MaterialsMain Body Stainless steel grade 304 & Steel powder coatingWork Surface Stainless steel grade 304Windows (Front / Side) Colorless and transparent UV absorbing 5mm tempered glass
IlluminationIntensity (lux) >1000FL lamp (W) 30W×2EA electronically ballasted FL LampUV lamp (W) 30W electronically ballasted UV Lamp
Electric Socket Outlets 230V socket, 120V socket
Dimensions (W×D×H)
Internal (mm / inch) 970×540×570 / 38.2×21.3×23.2 1270×540×570 / 50×21.3×23.2 1870×540×570 / 73.6×21.3×23.2External Without Stand (mm / inch) 1040×630×1060 / 40.1×24.8×42.7 1340×630×1060 / 52.8×24.8×42.7 1940×630×1060 / 76.4×24.8×42.7External With Stand (mm / inch) 1040×630×1780 / 40.1×24.8×70.1 1340×630×1780 / 52.8×24.8×70.1 1940×630×1780 / 76.4×24.8×70.1Weight (Body) (kg / lbs) 110 / 242.5 110 / 242.5 110 / 242.5Weight (Body+Stand) (kg / lbs) 130 / 302 150 / 330.7 190 / 418.9
Electrical Requirements (230V) 60Hz / 1ph / 1.7A 50Hz / 1ph / 1.82A 60Hz / 1ph / 1.7A 50Hz / 1ph / 1.82A 60Hz / 1ph / 1.7A 50Hz / 1ph / 1.82ACat. No. AAHA4011K AAHA4012K AAHA4021K AAHA4022K AAHA4031K AAHA4032KElectrical Requirements (120V) 60Hz / 1ph / 3.48A 60Hz / 1ph / 3.48A 60Hz / 1ph / 3.48A Cat. No. AAHA4013U AAHA4023U AAHA4033U
29
for Clean Bench
Accessories & Options for Clean Benches
HEPA Filter (1EA included)
- 99.99% efficient HEPA filter, industry standard size for economical replacement.
Electric Sockets (optional)
- Provided included a conveniently placed power source for small devices or equipment used within the cabinet. Two style of outlets are avail-able; 120V and 230V outlets.
Pre-Filter (1EA included)
- Replaceable pre-filter, to trap larger particles, extends HEPA filter life.
Differential Pressure Gauge (optional)
- Permanent magnhelic pressure differential gauge display across the HEPA filter to check the air changes.
UV Lamp (optional)
- For secondary method of decontamination while the bench is not in use.
Fume Hoods
Basic Stand (optional)
- Economical basic stand without casters made of powder coated steel.
Stand with Casters (optional)
- For easy transport with casters made of powder coated steel.
Service Fixture (optional)
- Conveniently hook up source a Gas/ Vacuum/ Air source within the working area.
- CSA limited (Canadian Standards Association)
Accessories for BC-01 / 11 / 21E
Cat. No. DescriptionAAAB1501 BCE-501 HEPA Filter for BC-01EAAAB1502 BCE-502 HEPA Filter for BC-11EAAAB1503 BCE-503 HEPA Filter for BC-21EAAAB1511 BCE-511 Pre Filter for BC-01EAAAB1512 BCE-512 Pre Filter for BC-11EAAAB1513 BCE-513 Pre Filter for BC-21EAAAB1521 BCE-521 Basic Stand for BC-01EAAAB1522 BCE-522 Basic Stand for BC-11EAAAB1523 BCE-523 Basic Stand for BC-21EAAAB1531 BCE-531 Stand with casters for BC-01E
※ In addition to providing standard accessories, we will manufacture customized accessories to meet your specific needs. Please contact Jeio Tech for details.
Cat. No. DescriptionAAAB1532 BCE-532 Stand with casters for BC-11EAAAB1533 BCE-533 Stand with casters for BC-21EAAAB1541 BCE-541 UV lamp for BC-01E (230V)AAAB1542 BCE-542 UV lamp for BC-01E (120V)AAAB1543 BCE-543 UV lamp for BC-11E (230V)AAAB1544 BCE-544 UV lamp for BC-11E (120V)AAAB1545 BCE-545 UV lamp for BC-21E (230V)AAAB1546 BCE-546 UV lamp for BC-21E (120V)AAAB1551 BCE-551 Electrical socket for BC-01/11/21EAAAB1561 BCE-561 Gas cock for BC-01/11/21EAAAB1571 BCE-571 Differential pressure gauge for BC-01/11/21E
30
Ductless Fume Hoods
DLH-01G Optional Accessories •Standwithcaster. •Differenttypesofchemicalfilters. see page 33 •6Differenttypesofworksurfaces.
Fume Hoods
Please visit .comFor further information on Jeio Tech´s Fume Hood products Information is readily available on our website.
31
Ductless Fume Hoods
Ductless Fume Hoods are manufactured and gonethrough a complete safety tests of rigorouslyinternational standards.
Constructional features • Internal airflow speed in the workspace can be identified with
attached anemometer. Airflow speed can be controlled by identifying varying wind speeds in accordance with the surroun-ding environments and filter conditions.
• Connection with a separate exhaust system is not required, since the hood uses reticulating air flow by discharging the filtered air into the laboratory.
• Other types of filter cartridges can be easily replaced by opening the upper cover located in the front.
• Front sash can be fully opened or fixed for easy transportation of experimental apparatuses and equipments into the workspace.
• A utility hole is manufactured in the fume hood, for use of appa-ratuses inside the hood allows for easy connection of power source or other cable outport sources outside the hood.
• A blower of large enough capacity is adopted into the equipment so sufficient intake air flow rate is maintained to reduce noise.
• A fluorescent light is provided outside the workspace so that the air flow is not hindered, prevents contamination of reagents and the illumination intensity is maintained.
• Various filters and work surfaces are available to fit your experimental needs. (Refer to accessory section)
Reliable Test : Efficiency, Capacity of Activated carbon filters tested according to
BS 7989:2001 : Structure, Electrical outlet, Lighting, Sound level tested according to
BS 7258-1:1994 : Local smoke, Large volume visualization, Face velocity, Tracer gas
tested according to ANSI / ASHRAE 110-1995, NF EN 14175-1
Selection for Chemical Filter
Code Filter Name ApplicationGF Activated carbon Filter All common laboratory chemicals, especially VOC, Organic, Benzene, Toluene, etcAC Acid Filter An acidic solvent; Acetic acid, Hydrochloric acid, etcHF Halogen Compound Filter Halogen compounds like Chlorine, Flourine, Iodine, Bromine, Astatine, etcFF Formaldehyde Filter Formadehyde applicationsAM Ammonia / Amine Filter Ammonia / Amines by chemisorptions
HEPA HEPA Filter The filtration efficiency of 99.99% at 0.3 microns For trapping biohazardous aerosols and other visible and non visible particles
Digital controller
Utility hole
Anemometer
Front cover
Fume Hoods
32
Ductless Fume Hoods
1. Exhaust Hole 2. Pre-filter 3. Front cover 4. Blower 5. Control Panel 6. Chemical filter 7. F.L. Lamp (INNER) 8. Anemometer 9. Front Door 10. Side viewing Panel 11. Door Opening Fixed Magnet 12. Utility Hole
Dimensions (Model: DLH-01G)
Fume Hoods
9
10
11
1
2
3 4
5
8
6
7
12
Air flow Diagram
Specifications & Ordering Informations
Model DLH-01G DLH-11GFume Hood Type Ductless
Permissibleenvironmental condition
Temperature 5℃ to 40℃Maximum relative humidity 80%
Altitude up to 2,000m
Controller Microprocessor controlFace Velocity Initial set point : 0.4m/s, 80fpmAir flow meter Swing Vane TypeMain Filter Chemical Filter (Optional 6 Different filters)
Pre-filter Washable High efficiency nylon filter
MaterialsMain body 2.0mm steel (Epoxy powder-coated)
Work surface Optional 6 Different work surfacesWindow (Front / Side) Acryl 8mm / Acryl 6mm
Fluorescent Light Intensity > 600lux Sound Emission 55dB at Normal Operation
Dimensions(W×D×H)
Internal (mm / inch) 880×640×800 / 34.6×25.2×31.5 1180×640×800 / 46.5×25.2×31.5External Without Stand (mm / inch) 900×660×1248 / 35.4×26×49.1 1200×660×1248 / 47.2×26×49.1External With Stand (mm / inch) 900×660×1953 / 35.4×26×76.8 1200×660×1953 / 47.2×26×76.8Weight (Body) (kg / lbs) 100 / 220.5 118 / 260.1Weight (Body+Stand) (kg / lbs) 120 / 264.6 140 / 308.6
Electric requirement AC 230V, 60Hz / 0.7ACat. No. AAAB2001 AAAB2011Electric requirement AC 230V, 50Hz / 0.6ACat. No. AAHB2002K AAHB2012KElectric requirement AC 120V, 60Hz / 1.3ACat. No. AAHB2003U AAHB2013UElectric requirement AC 100V, 50Hz / 1.5ACat. No. AAHB2004U AAHB2014U
33
Accessories & Options for Ductless Fume Hoods
Gas Detector and Tubes Filters
Work Surfase Stand with Caster
for Ductless Fume Hoods
Fume Hoods
Accessories for DLH-01G / 11G
Cat. No. DescriptionAAAB2521 Stand with casters for DLH-01G
AAAB2522 Stand with casters for DLH-11G
EDA9191 GF Activated carbon filter for DLH-01G
EDA9192 GF Activated carbon filter for DLH-11G
EDA9199 AC Acid filter for DLH-01G
EDA9200 AC Acid filter for DLH-11G
EDA9201 HF Halogen compounds filter for DLH-01G
EDA9202 HF Halogen compounds filter for DLH-11G
EDA9203 FF Formaldehyde filter for DLH-01G
EDA9204 FF Formaldehyde filter for DLH-11G
EDA9205 AM Ammonia / Amines filter for DLH-01G
EDA9206 AM Ammonia / Amines filter for DLH-11G
EDA9193 HEPA filter for DLH-01G
EDA9194 HEPA filter for DLH-11G
EDA9196 Prefilter for DLH-01G
EDA9198 Prefilter for DLH-11G
AAAB1531 BCE-531 Stand with casters for BC-01E
※ Above spec can be changed without prior notice.
Cat. No. DescriptionAAAB2501 Work surface (SUS #304) for DLH-01GAAAB2502 Work surface (SUS #304) for DLH-11GAAAB2503 Work surface (SUS #316L) for DLH-01GAAAB2504 Work surface (SUS #316L) for DLH-11GAAAB2505 Work surface (Ceramite) for DLH-01GAAAB2506 Work surface (Ceramite) for DLH-11GAAAB2507 Work surface (Polypropylene) for DLH-01GAAAB2508 Work surface (Polypropylene) for DLH-11GAAAB2509 Work surface (Bakelite) for DLH-01GAAAB2510 Work surface (Bakelite) for DLH-11GAAAB2511 Work surface (PVC) for DLH-01GAAAB2512 Work surface (PVC) for DLH-11GAAAB2531 Gas Detector (KITAGAWA AP-20)
EAA1550 Gas Detecting tube (Benzene, GASTEC-121SP (0.5-10ppm))
EDA9207 Gas Detecting tube (Toluene, GASTEC-122L (1-100ppm))
EAA1552 Gas Detecting tube (Acetic acid, GASTEC-81L (0.125-25ppm))
EAA1553 Gas Detecting tube (Chloroform, GASTEC-137 (4-400ppm))
EAA1554 Gas Detecting tube (Formaldehyde, GASTEC-91LL (0.05-1ppm))
EAA1555 Gas Detecting tube (Ammonia, GASTEC-3L (0.5-60ppm))
34
PCR Workstations & UV Sterilization cabinetsFume Hoods
Please visit .comFor further information on Jeio Tech´s Fume Hood products Information is readily available on our website.
PCR Workstation Included Accessories •HEPAFilter
See page 37 •Pre-Filter •UVLamp •FluorescentLamp
UV Sterilization cabinet Included Accessories •UVLamp
See page 37 •FluorescentLamp
35
PCR Workstations & UV Sterilization cabinetsFume Hoods
Using a HEPA filter provides an effective particulate-free working space for ambient environment conditions. – PW series
High quality UV lamp with a timer control feature is great for sterilizing the workspace before carrying out sensitive or PCR experiments. - UVC series
Constructional features
Effective sterilization 254nm ultraviolet lamp and Fluorescent lamp.
• Adjustable UV-timer for precise control of decontamination. - The variable digital timer for UV exposure with detail settings by
second. (Delay OFF: Max. 30min) - Long life (Up to 8,000 hour) UV lamp.
• Anti-glare fluorescent lamp is installed on the center ceiling of the work space area, minimizing shadows and relieves eye strain.
User-Friendly Control System • Microprocessor-based control system. • Bright and vivid LCD (PW - series) or VFD (UVC - series) display with
responsive touch buttons. • Easily indicating the total use time and operating time on the
screen.
A reliable interlock safety system • An audible alarm for product and sample protection against UV
over exposure. • For safety UV-opaque and resistant 99.99%, thick acryl front, back
and sides. • Automatic UV lamp safety shut OFF, in case the door is opened,
which prevents accidental UV exposure. • 304 grade stainless steel work surface - Highly durable and rust
free work zone, made for easy cleaning. (UVC-series)
• Self-protection against over-current.
Additional features
Filtration features (PW-series)
• Particle-free ISO 14644-1 HEPA filter (Class 4 conditions) - Using a 99.99% efficiency HEPA filter that filters particle sizes
of 0.3 micron and greater, traps biohazardous aerosols, and provides a particulate-free work environments that minimizes cross contamination.
• Neoprene gaskets ensures that the HEPA filter is airtight to the body unit.
- The HEPA filters life span depending on the test room conditions has a life span of 3 years.
• Replacing of the HEPA filter can easily be replaced by opening the upper cover, located in the front.
• Polyester fiber pre-filter that has minimal pressure loss and 85% arrestance on the A.F.L. test which serves to trap larger particles and increases the life of the main filter.
• Adjustable digital blower speed switch located in the front with use of large capacity blower is adopted into the equipment.
PCR Workstations
Digital controller
Air flow
UV Sterilization cabinet
Digital controller
36
PCR Workstations & UV Sterilization cabinetsFume Hoods
Specifications & Ordering Informations
PCR Workstations
Model PW-01 PW-11 PW-21
Air Flow type Vertical
Max. air volume (cmh / cfm) 557 / 327 697 / 408 929 / 546
Min. air volume (cmh / cfm) 167 / 97 209 / 121 279 / 162
Laminar airflow velocity (m / s / fpm) 0.3 / 60
Filter
Air cleanliness ISO 14644-1Class 4
HEPA Filter Typical efficiency of 99.99% at 0.3 ㎛ US MIL -STD -282 ; Micro glass fiber Media, Particle board, AL separator, Neoprene gaskets
Pre-Filter Polyester fibers with an efficiency of 85% (A·F·I TEST); AL frame, Polyester fiber Media
Noise level (dBA) Typically < 60 dBA at initial Blower speed
MaterialWork Surface Acryl 10mm (Clear type)
Window (Front, Side / Back) Acryl 8mm / 10mm (Clear type)
Illumination
IntensityFL lamp (lux) >1000
UV Density (㎼/cm2) 165 185 330
CapacityFL Lamp 15W×1EA 20W×1EA 30W×1EA
UV Lamp 15W×1EA 20W×1EA 30W×1EA
Dimensions (W×D×H)
Interior (mm / inch) 700×585×602 / 27.5×23×23.7 880×585×602 / 34.6×23×23.7 1180×585×602 / 46.5×23×23.7
Exterior (mm / inch) 720×605×964 / 28×24×38 900×605×964 / 35.4×24×38 1200×605×964 / 47.2×24×38
Weight (Body) (kg / lbs) 56.2 / 123.9 64.2 / 141.5 77.8 / 171.5
Electric requirement (230V) 60Hz, 1.3A 50Hz, 1.3A 60Hz, 1.4A 50Hz, 1.4A 60Hz, 1.5A 50Hz, 1.5A
Cat. No. AAHB3001 AAHB3002 AAHB3011 AAHB3012 AAHB3021 AAHB3022
Electric requirement (120V) 60Hz, 2.2A 60Hz, 2.7A 60Hz, 2.9A
Cat. No. AAHB3003 AAHB3013 AAHB3023
Specifications & Ordering Informations
UV Sterilization cabinet
Model UVC-01 UVC-11 UVC-21
Illumination
IntensityFl lamp (Lux) >800 >900 >1000
UV Density (㎼ / ㎠) 150 385 450
CapacityFl lamp 8W×1ea 15W×1ea 20W×1ea
UV lamp 8W×1ea 15W×1ea 20W×1ea
MaterialWork Surface Stainless steel grade 304
Window (Front, Back / Side) Acryl 5 mm (Clear type)
Dimensions (W×D×H)
Interior (mm / inch) 433×500×468 / 17.0×19.7×18.4 583×500×468 / 23.0×19.7×18.4 880×500×468 / 34.6×19.7×18.4
Exterior (mm / inch) 450×509×610 / 17.7×20.0×24.0 600×509×610 / 23.6×20.0×24.0 900×509×610 / 35.4×20.0×24.0
Weight (Body) (kg / lbs) 15.0 / 33.1 17.5 / 38.6 20.0 / 44.1
Electric requirement (230V) 60Hz, 0.1A 50Hz, 0.1A 60Hz, 0.2A 50Hz, 0.2A 60Hz, 0.3A 50Hz, 0.3A
Cat. No. AAHB4001 AAHB4002 AAHB4011 AAHB4012 AAHB4021 AAHB4022
Electric requirement (120V) 60Hz, 0.2A 60Hz, 0.4A 60Hz, 0.6A
Cat. No. AAHB4003 AAHB4013 AAHB4023
※ Above spec can be changed without prior notice.
37
Accessories & Options for PW / UVC seriesFume Hoods
General UV dose and time required
PathogenAverage UV dose
required (㎼ . s/㎠)
Average UV time required (㎼/ ㎠ /sec.)
PW-01 UVC-01 PW-11 UVC-11 PW-21 UVC-21165 150 185 385 330 450
S. enteritidis 4,000 25 27 22 10 13 9
B. megatherium sp. (spores) 2,730 17 18 15 7 9 6
B. subtilis 7,100 43 47 39 18 22 16
Eberthella typhosa 2,140 13 14 12 6 7 5
Escherichia coli (E. coli) 3,000 19 20 17 8 10 7
Micrococcus candidus 6,050 37 40 33 16 19 13
Proteus vulgaris 2,640 16 18 15 7 8 6
Pseudomonas aeruginosa 5,500 34 37 30 14 17 12
Pseudomonas aeruginosa 3,500 22 23 19 9 11 8
S. typhimurium 8,000 49 53 44 21 25 18
Shigella paradysenteriae 1,680 101 11 10 4 6 4
Spirillum rubrum 4,400 27 29 24 11 14 10
Staphylococcus albus 1,840 12 12 10 5 6 4
* Environment Condition : temperature 20~25℃, Relative humidity 60%* General purpose use and average disinfection applications
Accessories for PW - 01/11/21
Cat. No. Description
EDA9219 HEPA filter for PW-01
EDA9220 HEPA filter for PW-11
EDA9221 HEPA filter for PW-21
CHE4436 Lighting Lamp for PW-01
CHE4410 Lighting Lamp for PW-11
CHE4409 Lighting Lamp for PW-21
CHE4431 UV Lamp for PW-01
CHE4427 UV Lamp for PW-11
CHE4423 UV Lamp for PW-21
Accessories for UVC- 01/11/21
Cat. No. Description
CHE4435 Lighting Lamp for UVC-01
CHE4436 Lighting Lamp for UVC-11
CHE4410 Lighting Lamp for UVC-21
CHE4434 UV Lamp for UVC-01
CHE4431 UV Lamp for UVC-11
CHE4427 UV Lamp for UVC-21
HEPA Filter
Pre-Filter
Only for PW Series
PW and UVC Series
UV Lamp
Fluorescent Lamp
General Incubators.Low Temperature Incubators. Low Temperature Personal Incubators. Incubated & Refrigerated & Illuminated Shakers.
Incubators
Selection GuideIncubators
DescriptionOperating
Temp. Range(℃/℉)
ChamberVolume
(L /cu ft)
TemperatureFluctuation
at 37℃ [±℃/℉]
TemperatureVariation
at 37℃ [±℃/℉]
Page
Generaltype
IB-05GAmb. +5 to 70/ Amb. +9 to 158
60 / 2.10.1 / 0.18
0.6 / 1.08 40IB-15G 102 / 3.6 0.2 / 0.36
IB-25G 151 / 5.3 0.2 / 0.36 0.6 / 1.08
Economic type
IB-01E Amb. +3 to 60/ Amb. +5.4 to 140
65 / 2.3 0.2 / 0.36 0.6 / 1.0841IB-11E 150 / 5.3 0.3 / 0.54 0.8 / 1.44
IB-21E 205 / 7.2 0.1 / 0.18 1.1 / 1.98
Low Temperature Incubators
DescriptionOperating
Temp. Range(℃/℉)
ChamberVolume (L /cu ft)
TemperatureFluctuation
at 37℃[±℃/℉]
TemperatureVariation
at 37℃[±℃/℉]Page
Convectiontype
IL -11 0 to 60/ +32 to 140
150 / 5.30.1 / 0.18
0.5 / 0.942
IL -21 224 / 8.6 0.4 / 0.72
Air Jacket type
IL -11A +4 to 60/ +39.2 to 140
162 / 5.7 0.2 / 0.36 0.5 / 0.9 44
IL -21A 254 / 9.0
Personal type
ILP -02 10~40℃ at ambient temperature 25℃
14 / 0.50.1 / 0.18
0.5 / 0.945
ILP -12 48 / 1.7 0.4 / 0.72
Incubated & Refrigerated & Illuminated Shakers
DescriptionOperating
Temp. Range(℃/℉)
Speed Range[RPM]
MaximumAmplitude Size (dia)
Page
Benchtoptype
SI-300Incubated Shakers Amb. +5 to 60
/ Amb. +9 to 140
10 to 300
40mm(1.6” dia) 46
SI-600SI-300R Incubated & Refrigerated
Shakers+15 to 60 / +59 to 140SI-600R
Floor type
IS-971 Incubated Shakers Amb. +5 to 60/ Amb. +9 to 140
70mm(2.8” dia) 48IS-971R Incubated & Refrigerated
Shakers+4 to 60 / +40 to 140
IS-971RF Incubated & Refrigerated & Illuminated Shakers
Amb. -15 to 60 / Amb. -27 to 140
Chambertype
SIF-5000Incubated Shakers Amb. +5 to 80
/ Amb.+9 to 17610 to 300 (Stackable Top : 10 to 250)
19 mm dia(0.75” dia)
50SIF-6000 25 mm dia
(1.0” dia)
SIF-5000R Incubated & Refrigerated Shakers
Amb. -20 to 80 / Amb. -36 to 176
19 mm dia(0.75” dia)
SIF-6000R 25 mm dia(1.0” dia)
Accessories & OptionsDescription Page
for Incubators52 - 54
for Incubated & Refrigerated & Illuminated Shakers
Safety functions1) Self-protecting cut-off function and signal - For over temperature, the power supply is
automatically cut from the heater and controller systematically before the unit shuts down.
- 2 separate over-current fuses for user safety.
2) Time setting function for automated ON / OFF. - Integrated time setting: Delayed ON / OFF. (from 1 min to 99 hr 59 min) - Operating settable function: After a power inter-
ruption, select automated run or manual run.
3) Door-open warning alarm : - Intermittent tone and optical signal alarm 5 min.
after automated cut-off. - Heating element and fan automaically stop
when door opening to minimize heat loss and protect operator.
Optimum control performance1) Profession electronic controls and program control. - Microprocessor PID temperature control with
very simple calibration and auto-tuning features. - Conveniently preset 3 most commonly used
temperature settings. - Select between Celsius and Fahrenheit. - Self-diagnostic function identifies any errors and
advises the user with the correct procedure.
2) Applicable control display considering HMI (Human Machine Interface) network system :
- Very similar key arrangement throughout the whole temperature chambers, bath circulators and shakers series.
- Operator-friendly controller with the splash-proof / easy-to-clean keypads and clear LED displays.
- A quick lock button prevents accidental resetting of parameters. (Only incubatator series)
- Shaker and lamp mechanism have their own ON / OFF switch for independent incubation.
(Only SI, SIF, IS-971RF series)
Ideal construction 1) High quality 304 grade stainless steel inner cha-
mber and dirt-repellent powder coating external surface.
2) Perfectly sealed door gasket minimizes heat loss and fully insulated chambers keep the exterior at a safe temperature.
3) Adjustable stainless steel and electro polished wire shelves allows for better air-flow and allow for easy clean. (Only IB, SIF series)
Technical Benefits
General ApplicationsGeneral applications
General, Low temp. & Low temp. personal Incubators
Incubated & Refrigerated & Illuminated Skakers
IB series IL series ILP series SI & SIF series IS seriesAntibody Testing • • •Bacterial Research • •Bacterial suspensions • •Chemical Storage • •Chick Embryo Studies • •Clinical Science • • •Cultivating Low Temperature Microbesand Plant Cells •
Crystallization Studies • •Cultivating Thermophilic Bacteria •Drying And Staining Procedures • •Denaturalizing Tests for Food • •Environmental technology(waste water and soil analysis) • •
Enzyme Digestion Studies • •Extraction procedures • •Fermentation(Pharmacy and biotech -DNA and Enzymes) • •
General mixing • •Hematological Testing • • •Histochemical Procedures • •Measuring COD/ BOD •Medical researches. (Diagnostic tests) • •Microbiological Determinations • • •Microorganism • • •Molecular biology • •Organism Germs for Life Science • • •Organism Pharmacy • • •Paraffin Embedding • •Pharmaceutical Stability Testing •Plasmid purification • •Protein expression in bacteria • •Solubility • •Staining and destaining • •Tissue Culturing • • •
* General purpose use and storage applications
40
Incubators - General type
Exclusive gravity convection type incubators for all laboratory purposes.IB-G series are the most useful incubators for general purpose use air-jacketed convection style for excellent temperature variation without external air disturbance.
Operating features • U+5℃ above room temperature to 70℃. • Microprocessor PID control / Auto-tuning / Calibration. • Digital timer: 1 min ~ 99 hr 59 min, delayed ON / OFF. • Over-temperature limiter / Door open alarm. • 3 different temperature values memorable. • Digital LED display (0.1℃ resolution) using touch-sensitive keypads. • RS-232 interface available.
Constructional features • Fully insulated dual-wall door with rubber magnetic seal gasket
keeps setting temperature. • Stackable two high using the stacking kit. (optional)
• Optimized sample inspection through a tempered inner glass door without affecting the chamber temperature.
• Detachable shelves and rounded inner chamber corners for easy cleaning.
• Highly durable incoloy heating element with fins that guarantee better radiation.
• Attach other electric instruments to the inside of the chamber through a side cable port.
• Cable port allow for control of the amount of airflow in the cha-mber. (dia 38mm/1.5℃, Provided silicon or rubber cap)
IB-05G Included Accessories •2wireshelves
Optional Accessories •Perforatedshelves see page 52 •Stackingkitsforstackablechambers
Incubators
Specifications & Ordering Informations
Model IB-05G IB-15G IB-25GChamber Volume (L / cu ft) 60 / 2.1 102 / 3.6 151 / 5.3
TemperatureRange (℃ / ℉) Amb. +5 to 70 / Amb. +9 to 158Fluctuation 1) (±℃ / ℉) at 37℃ 0.1 / 0.18 0.1 / 0.18 0.2 / 0.36Variation 1) (±℃ / ℉) at 37℃ 0.6 / 1.08 0.2 / 0.36 0.6 / 1.08
Dimensions(W×D×H)
Interior (mm / inch)400×360×420 / 15.7×14.2×16.5
480×410×520 / 18.9×16.1×20.5
610×460×540 / 24×18×21.3
Exterior (mm / inch)595×555×745 / 23×22×29
675×605×855 / 27×24×34
805×655×885 / 32×26×35
Net weight (Kg / lbs) 45 / 99 55 / 121 62 / 136Electrical Requirements (230V, 50 / 60Hz) 1.3A 2.2A 3.1ACat. No. AAH21162K AAH21172K AAH21182KElectrical Requirements (120V, 50 / 60Hz) 2.8A 4.6A 6.4ACat. No. AAH21166U AAH21176U AAH21186U
1) Technical data. (according to DIN 12880)
41
Specifications & Ordering Informations
Model IB-01E IB-11E IB-21EChamber Volume (L / cu ft) 65 / 2.3 150 / 5.3 205 / 7.2
TemperatureRange (℃ / ℉) Amb. +3 to 60 / Amb. +5.4 to 140Fluctuation 1) (±℃ / ℉) at 37℃ 0.2 / 0.36 0.3 / 0.54 0.1 / 0.18Variation 1) (±℃ / ℉) at 37℃ 0.6 / 1.08 0.8 / 1.44 1.1 / 1.98
Dimensions(W×D×H)
Interior (mm / inch)423×355×445 / 16.7×14×17.5
500×515×585 / 19.7×20.3×23
632×515×630 / 24.9×20.3×24.8
Exterior (mm / inch)533×475×725 / 21×18.7×28.5
595×630×865 / 23.5×24.8×34
740×630×910 / 29.1×24.8×35.8
Net weight (Kg / lbs) 33 47 57Electrical Requirements (230V, 50 / 60Hz) 1.1A 2.2A 2.4ACat. No. AAH26015K AAH26025K AAH26035KElectrical Requirements (120V, 50 / 60Hz) 2.1A 4.2A 4.6ACat. No. AAH26016U AAH26026U AAH26036U
1) Technical data. (according to DIN 12880)
Incubators - Economic type
Space saving design and dependable, trouble-free heating system.
Operating features • +3℃ above room temperature to 60℃. • Microprocessor PID control / Auto-tuning / Calibration. • Digital timer: 1 min ~ 99 hr 59 min, delayed ON / OFF. • Over-temperature limit / Door open alarm. • Preset 3 most commonly used temperature settings. • Digital LED display (0.1℃ resolution) using touch-sensitive keypads.
Constructional features • Completely safe anti-vibration design is helpful for cultivating yeast. • Space saving dimensions, lightweight, and compact design with
fully sealed gasket. • Stackable two high using the stacking kits. (optional)
• Without affecting the chamber temperature Sample inspection viewing is made easy due to the inner tempered glass door.
• Detachable shelves and rounded inner chamber corners allow for easy cleaning.
IB-E series complete inner chamber is a film type heater that is perfectly safe, it is vibration and noise free, and in addition it is most likely to not have mechanical troubles.
IB-01EIncluded Accessories •2wireshelves
Optional Accessories •Perforatedshelves see page 52 •Stackingkitsforstackablechambers
Incubators
42
Low Temperature Incubators
IL-21 / IL-21A
Incubators
Please visit .comFor further information on Jeio Tech´s Low Temperature Incubators products Informationisreadilyavailableonourwebsite.
43
Low Temperature Incubators - Forced Convection
Intensive low temperature incubating performance with compressor cooling system.IL series has an excellent HBP type compressor cooling system which is noiseless and reduces water-evaporation within the chamber.
IL-21Included Accessories •2wireshelvesforIL-11 •3wireshelvesforIL-21
Optional Accessories •Perforatedshelves see page 52
Incubators
Operating features • 0℃ to 60℃. • Microprocessor PID control / Auto-tuning / Calibration. • Digital timer: 1 min ~ 99 hr 59 min, delayed ON / OFF. • Over-temperature limit / Door open alarm. • Preset 3 most commonly used temperature settings. • 9 step temperature and up to 200 cycles of repetition
programmable for each profile. • Adjustable 3 step fan speed with defrosting time / period control. • Digital LED display (0.1℃ resolution) using touch-sensitive keypad. • RS-232 interface available.
Constructional features • Forced-air convection with an optimal cross flow type fan for
excellent variation. • Large size chamber with maximum of 244L. (8.6cu ft) • One electrical outlet with a safety cover which other electronic
instruments can be used in the chamber. • viewing is made easy due to the inner tempered glass door. • Detachable shelves and rounded inner chamber corners allow for
easy cleaning.
Specifications & Ordering Informations
Model IL -11 IL -21Chamber Volume (L / cu ft) 150 / 5.32 244 / 8.6 Refrigerator (Hp) 1 / 8 HBP 1 / 6 HBP
TemperatureRange (℃ / ℉) 0 to 60 / +32 to 140Fluctuation 1) (±℃ / ℉) at 25℃ 0.1 / 0.18Variation 1) (±℃ / ℉) at 25℃ 0.5 / 0.9 0.4 / 0.72
Dimensions(W×D×H)
Interior (mm / inch)600×500×500 / 24.0×20.0×20.0
500×520×940 / 20.0×20.5×37.0
Exterior (mm / inch)735×742×1010 / 28.9×29.0×40.0
635×740×1630 / 25.0×29.0×64.0
Net weight (Kg / lbs) 100 / 220.0 135 / 297.0Electrical Requirements (230V) 50Hz, 4.5A 60Hz, 4.5A 50Hz, 6.4A 60Hz, 6.4ACat. No. AAH22042K AAH22041K AAH22052K AAH22051KElectrical Requirements (120V) 60Hz, 8.3A 60Hz, 10.6ACat. No. AAH22046U AAH22056U
1) Technical data (according to DIN 12880)
44 Operating features
• +4℃ to 60℃. • Microprocessor PID control / Auto-tuning / Calibration. • Digital timer: 1 min ~ 99 hr 59 min, delayed ON / OFF. • Over-temperature limit / Door open alarm. • Preset 3 most commonly used temperature settings. • 9 step temperature and up to 200 cycles of repetition program-
mable for each profile. • Adjustable defrosting time / period control. • Digital LED display (0.1℃ resolution) using touch-sensitive keypad. • RS-232 interface available.
Constructional features • Air-jacketed type: independently exchanges heat outwardly with
inner gravity convection. • Large size chamber with a maximum volume of 254L. (9cu ft) • One electrical outlet with safety cover allows use of other electric
instruments in the chamber. • Viewing is made easy due to the inner tempered glass door. • Detachable shelves and rounded inner chamber corners allow for
easy cleaning.
IL-11A Included Accessories •2wireshelvesforIL-11A •3wireshelvesforIL-21A
Optional Accessories •Perforatedshelves see page 52
Low Temperature Incubators - Air-jacket
Air-jacketed convection type incubators, prevent outside air disturbance in the inner chamber and has excellent temperature variation.IL-A series is perfectly safe from water-evaporation due to the use of an evaporator cooling system or blower, especially ideal for incubating tests that consist of easily drying samples outside.
Incubators
Specifications & Ordering Informations
Model IL -11A IL -21AChamber Volume (L / cu ft) 162 / 5.7 254 / 9.0Refrigerator (Hp) 1 / 6 HBP 1 / 4 HBP
TemperatureRange (℃ / ℉) +4 to 60 / +39.2 to 140Fluctuation 1) (±℃ / ℉) at 25℃ 0.2 / 0.36Variation 1) (±℃ / ℉) at 25℃ 0.5 / 0.9
Dimensions(W×D×H)
Interior (mm / inch)600×540×500 / 24×21.3×20
500×540×940 / 20×21.3×37
Exterior (mm / inch)770×772×1060 / 30×30×42
670×760×1680 / 26×30×66
Net weight (Kg / lbs) 108 / 238.1 145 / 319.7Electrical Requirements (230V) 50Hz, 6.9A 60Hz, 6.9A 50Hz, 8.4A 60Hz, 8.4ACat. No. AAH22062K AAH22061K AAH22072K AAH22071KElectrical Requirements (120V) 60Hz, 10.2A 60Hz, 12.3ACat. No. AAH22063U AAH22073U
1) Technical data. (according to DIN 12880)
45
Low Temperature Personal Incubators
Compact, lightweight with reliable incubating performance for important testing.
Operating features • +10℃ to 40℃ at room temperature 25℃. • Microprocessor PID control / Auto-tuning / Calibration. • Digital timer: 1 min ~ 99 hr 59 min, delayed ON / OFF. • Over-temperature limit. • Preset 3 most commonly used temperature settings. • 9 step temperature and up to 200 cycles of repetition program-
mable for each profile. • Adjustable 3 step fan speed with defrosting time / period control. • Digital LED display (0.1℃ resolution) using touch-sensitive keypad. • RS-232 interface available.
Constructional features • Tempered inner glass door is equipped with all models! (14L / 48L)
• Maximum 2×1000mL Erlenmeyer flasks can be stored in the smallest chamber. (14L)
• Environment-friendly insulation material-EPDM used for safety and convenience. (ASTM-C534)
• Space-saving compact size on bench-top and easily stackable.
ILP series has a thermal electric module-Peltier cooling chip type which is very quiet, with no vibration, and small generation of heat to just fit a bench-top personal incubator!
ILP-02 stackable chambers Included Accessories •1wireshelfforILP-02 •2wireshelvesforILP-12
Optional Accessories •Perforatedshelves see page 52
Incubators
Specifications & Ordering Informations
Model ILP -02 ILP -12Chamber Volume (L / cu ft) 14 / 0.5 48 / 1.7
TemperatureRange (℃ / ℉) 10~40℃ (50~104℉) at ambient temperature 25℃
Fluctuation 1) (±℃ / ℉) at 25℃ 0.1 / 0.18Variation 1) (±℃ / ℉) at 25℃ 0.5 / 0.9 0.4 / 0.72
Dimensions(W×D×H)
Interior (mm / inch)315×200×230 / 12.4×7.9×9.1
334×334×430 / 13.1×13.1×17
Exterior (mm / inch)430×495×400 / 17×19.4×15.7
430×665×620 / 17×26.2×24.4
Net weight (Kg / lbs) 27.5 / 60.6 49 / 108Electrical Requirements (230V) 50Hz, 1.8A 60Hz, 1.8A 50Hz, 3.5A 60Hz, 3.5ACat. No. AAH24032K AAH24031K AAH24042K AAH24041KElectrical Requirements (120V) 60Hz, 3.4A 60Hz, 6.7ACat. No. AAH24033U AAH24043U
1) Technical data. (according to DIN 12880)
46
SI-600R Control Display
Incubated Shakers - Benchtop type
SI-600R Optional Accessories •Universal/Dedicatedplatforms,Rubbermats,Universalattachments see page 78-81 •Flaskclamps,Funnelclamps •Testtuberacks,Springwireracks •Microplateholders(three styles) •Labsticker
Incubators
Please visit .comFor further information on Jeio Tech´s Incubated Shaker products Informationisreadilyavailableonourwebsite.
47 Shaking features • Select between orbital or reciprocating action. • Speed range: 10 to 300 rpm. • Programmable shaking motion. - Run time: 10 sec to 999 hr 59 min 59 sec. - Forward & Backward, Pause: 10 sec to 59 min 59 sec. • Maximum orbit size: 40mm dia. (1.6˝ dia.)
Operating features • +5℃ above room temperature to 60℃ for SI-300, 600. • +15℃ to 60℃ for SI-300R, 600R. • Microprocessor PID control / Auto-tuning / Calibration. • Digital timer: 1 min to 99 hr 59 min, delayed ON / OFF. • Over-temperature limit/ Door open alarm . • Digital LED display for temperature (0.1℃ resolution), speed, and
shaking motion • Preset 3 most commonly used temperature settings. • 9 step temperature and up to 200 cycles of repetition
programmable for each profile. • Adjustable 3 step fan speed . • RS-232 interface available.
Constructional features • Brushless DC motor for long maintenance-free use. • High-velocity fan ensures rapid thermal recovery and excellent
temperature variation. • Gas spring door and lid guards against sudden closures. • Acryl lid and inner lamp functions allow observation of flask
contents. • Uses CFC-free refrigerant. (for SI - 300R, 600R)
• Attached fluorescent lamp offered bright observation in a chamber.
Inside of SI series
Incubated Shakers - Benchtop type
Combines a benchtop incubator, refrigerator with dual-action in orbital and reciprocating shaker. Fulfills a variety of molecular biology, general incubation, and cell culture applications.
Digital incubating/ refrigerating benchtop shakers.
Incubators
Specifications & Ordering Informations
Model SI-300 SI-300R SI-600 SI-600R
Temperature
Range (℃ / ℉) Amb. +5 to 60 (Amb. +9 to 140) for SI-300, 600
+15 to 60 (+59 to 140) for SI-300R, 600RFluctuation 1) at 37℃ (±℃ / ℉) 0.3 / 0.54 0.6 / 1.08 0.1 / 0.18 0.2 / 0.36Variation 1) at 37℃ (±℃ / ℉) 1.6 / 2.88 1.5 / 2.7 0.7 / 1.26 0.3 / 0.54
Refrigerator (Hp) -1 / 8 HBP (220V, 230V)
-1 / 8 HBP (220V, 230V)
1 / 6 HBP (100V, 120V) 1 / 6 HBP (100V, 120V)
Shaking system
Motion type Orbital or Reciprocating motion selectableSpeed range (RPM) 10 to 300
Timer Run time: 10 sec to 999 hr 59 min 59 secForward & Backward, Pause: 10 sec to 59 min 59 sec
Amplitude size (mm / inch, dia.) 20,30,40/0.8,1.2,1.6Available-Standard30/1.2Recip stroke length (mm / inch) 20,30,40/0.8,1.2,1.6Available-Standard30/1.2
Dimensions
Volume (L / cu ft) 53 / 1.9 83 / 2.9Platform (W×D) (mm / inch) 350×350 / 13.8×13.8 450×450 / 17.7×17.7Internal (W×D×H) (mm / inch) 410×410×320 / 16.1×16.1×12.6 510×510×320 / 20.1×20.1×12.6Overall (W×D×H) (mm / inch) 442×740×622 / 17.4×29.1×24.5 542×850×622 / 21.4×33.5×24.5Net weight (Kg / lbs) 74 / 163 85 / 187 91 / 200 102 / 225
Electrical Requirements (230V) 50 / 60Hz, 4.0A 60Hz, 5.5A 50Hz, 5.5A 50 / 60Hz, 4.0A 60Hz, 5.5A 50Hz, 5.5ACat. No. AAH23105K AAH23111K AAH23112K AAH23205K AAH23211K AAH23212KElectrical Requirements (120V) 50 / 60Hz, 7.5A 60Hz, 10.1A 50 / 60Hz, 7.5A 60Hz, 10.1ACat. No. AAH23106U AAH23113U AAH23206U AAH23213U
1) Technical data. (according to DIN 12880)
48
IS-971R Control Display
Incubated Shakers - Floor type
IS-971R Optional Accessories •Universal/Dedicatedplatforms,Rubbermats,Universalattachments see page 53-55 •Flaskclamps,Funnelclamps •Testtuberacks,Springwireracks •Microplateholders(three styles) •Labsticker
Incubators
Please visit .comFor further information on Jeio Tech´s Incubated Shaker products Informationisreadilyavailableonourwebsite.
Certification only for the IS-971/971R
49
Incubated Shakers - Floor type
Large and heavy capacity shaking with rapid heating / cooling performance.Advanced shaking for heavy workload and flask up to maximum 4×6L.Exclusive drive mechanism delivers years of dependable service.
Shaking features • Select between orbital or reciprocating action. • Speed range: 10 to 300 rpm. • Programmable shaking motion. - Run time: 10 sec to 999 hr 59 min 59 sec. - Forward & Backward, Pause: 10 sec to 59 min 59 sec. • Maximum orbit size: 70mm dia. (2.8˝ dia.)
Operating features • +5℃ above room temperature to 60℃ for IS-971
-15℃ above room temperature to 60℃ for IS-971RF +4℃ to 60℃ for IS-971R.
• Microprocessor PID control / Auto-tuning / Calibration. • Digital timer: 1 min to 99 hr 59 min, delayed ON / OFF. • Over-temperature limit/ Door open alarm. • Digital LED display for temperature (0.1℃ resolution), speed, and
shaking motion. • Preset 3 most commonly used temperature settings. • 9 step temperature and up to 200 cycles of repetition
programmable for each profile. • Adjustable 3 step fan speed with defrosting time / period control. • RS-232 interface available.
Constructional features • Brushless DC motor for long maintenance-free use. • High-velocity fan ensures rapid thermal recovery and excellent
temperature variation. • Viewing window in top-opening provides a clear inner chamber
view, minimizing the need for opening the lid. (without IS - 971RF)
• Controlling 5 steps illumination lamp available. (Max. 12,000 lux IS-971RF)
• Gas spring door and lid guards against sudden closures. • Casters easily makes the unit mobile. • Door can be secured with a lock and key. • Uses CFC-free refrigerant. (for IS-971R, IS-971RF)
Inside of IS series
Incubators
Specifications & Ordering Informations
Model IS-971 IS-971R IS-971RF
Temperature
Range (℃ / ℉) Amb. +5 to 60
/ Amb. +9 to 140 +4 to 60 / +40 to 140 Amb. -15 to 60 / Amb. -27 to 140
Fluctuation 1) at 37℃ (±℃ / ℉) 0.2 / 0.36Variation 1) at 37℃ (±℃ / ℉) 0.8 / 1.44
Refrigerator - 1 / 3 LBP (AC 120V) 1 / 3 LBP (AC 120V)
- 1 / 6 HBP (AC 230V) 1 / 4 HBP (AC 230V)
Shaking system
Motion type Orbital or Reciprocating motion selectableSpeed range (RPM) 10 to 300
Timer Run time : 10 sec to 999 hr 59 min 59 secForward & Backward, Pause: 10 sec to 59 min 59 sec
Amplitude size (mm / inch, dia.) 30,40,50,60,70/1.2,1.6,2.0,2.4,2.8Available-Standard30/1.2Recip stroke length (mm / inch) 30,40,50,60,70/1.2,1.6,2.0,2.4,2.8Available-Standard30/1.2
Dimensions
Volume (L / cu ft) 270 / 9.5Platform (W×D) (mm / inch) 755×481 / 29.7×18.9 Internal (W×D×H) (mm / inch) 894×634×480 / 35.2×25.0×18.9
Overall (W×D×H) (mm / inch)1,132×810×1,045 /
44.6×31.9×41.11,132×810×1,075 / 44.6×31.9×42.3
Net weight (Kg / lbs) 180.0 / 396.8 195.0 / 429.9 210.0 / 462.9Electrical Requirements (230V) 50 / 60Hz, 5.2A 60Hz, 7.3A 50Hz, 7.3A 60Hz, 9.3A 50Hz, 9.3ACat. No. AAH23306K AAH23321K AAH23322K AAH23351K AAH23352KElectrical Requirements (120V) 60Hz, 11.2A 60Hz, 13.8A 60Hz, 17.0ACat. No. AAH23336U AAH23346U AAH23356U
1) Technical data. (according to DIN 12880)※Certification only for the IS-971, IS-971R.
Certification only for the IS-971/971R
50
Incubated Shakers - Chamber type
Incubators
SIF-6000R Control Display
SIF-6000R Included Accessories •2wireshelves Optional Accessories •Universal/Dedicatedplatforms,Rubbermats,Universalattachments see page 52-55 •Flaskclamps,Funnelclamps •Testtuberacks,Springwireracks •Microplateholders(three styles) •Labsticker
Please visit .comFor further information on Jeio Tech´s Incubator products Informationisreadilyavailableonourwebsite.
51
Incubated Shakers - Chamber type
Space- saving provides various locations on/under your lab benches, or double-stacked on the FloorMulti-purpose laboratory incubated shakers accept flasks up to 2ea x 6 L (SIF-6000(R)). Two adjustable-height shelves provide added incubating or storage samples.
Incubators
Shaking features • Select between orbital or reciprocating action. • Speed range: 10 to 300 rpm. (Stackable Top :10 to 250) • Programmable shaking motion. - Run time: 10 sec to 999 hr 59 min 59 sec. - Forward & Backward, Pause: 10 sec to 59 min 59 sec. • Maximum orbit size : 19mm / 0.75″ dia (SIF 5000/R),
25mm / 1.0″ dia (SIF 6000/R)
Operating features • +5℃ above room temperature to 80℃ for SIF-5000/6000
-20℃ below room temperature to 80℃ for SIF-5000R/6000R • Microprocessor PID control / Auto-tuning / Calibration. • Digital timer: 1 min to 99 hr 59 min, delayed ON / OFF. • Over-temperature limit / Door open alarm. • Digital LED display temperature (0.1℃ resolution), speed and shaking
motions. • Preset 3 most commonly used temperature settings. • 9 step temperature and up to 200 cycles of repetition programmable
for each profile. • Adjustable fan speed within 3 steps and defrosting time / period
control. • RS-232 interface available.
Constructional features • Brushless DC motor for long maintenance-free use. • Stackable 2 steps up to maximize spave efficiency. • High-velocity fan ensures rapid thermal recovery and excellent
temperature variation. • Viewing window in the front-opening provides a clear inner
chamber view, minimizing the need for opening the lid. • Observation lamp as standard. • Electrical socket inside chamber provides power to small equipments • Casters easily makes the unit mobile. • Door can be secured with a lock and key. • Uses CFC-free refrigerant. (For SIF-5000R/6000R)
Inside of SIF series
Specifications & Ordering Informations
Model SIF-5000 SIF-5000R SIF-6000 SIF-6000R
Temperature 1)
Range (℃ / ℉) Amb.+5 to 80 [Amb.+41 to 176] for SIF -5000, 6000
Amb.-20 to 80 [Amb. -4 to 176] for SIF -5000R, 6000RFluctuation at 37℃ (±℃ / ℉) 0.1 / 0.18Variation at 37℃ (±℃ / ℉) 1.0 / 1.8Refrigerator (Hp) - 1/8Hp, HBP - 1/6Hp, HBP
Shaking system
Motion type Orbital or Reciprocating motion (Default : Orbital motion)
Speed range (RPM) 10 to 300 (Stackable Top :10 to 250)
Timer Run time(10sec ~ 999hr 59min 59sec) Pause, Forward, Backward(10sec ~ 59min 59sec)
Amplitude size (mm / inch, dia.) 13,19/0.5,0.75Available-Standard19/0.75Recip stroke length (mm / inch) 19,25/0.75,1.0Available-Standard25/1.0
Dimensions
Volume (L / cu ft) 80 / 2.8 150 / 5.3Platform (W×D, mm / inch) 350×350 / 13.8x13.8 450×450 / 17.7×17.7Interior (W×D×H, mm / inch) 440×440×418 / 17.3×17.3×16.5 540×540×518 / 21.3×21.3×20.4 Exterior (W×D×H, mm / inch) 570×815×900 / 22.4×32.1×35.4 670×895×980 / 26.4×35.2×38.6Shelves (Standard / Max) 2 / 8 2 / 11Net weight (kg / Ibs) 120 / 264.6 130 / 286.6 140 / 308.6 150 / 330.7
Electrical Requirements (230V) 50 / 60Hz, 5.4A 60Hz, 7.2A 50Hz, 7.2A 50 / 60Hz, 5.4A 60Hz, 7.3A 50Hz, 7.3ACat. No. AAH27025K AAH27121K AAH27122K AAH27015K AAH27111K AAH27112KElectrical Requirements (120V) 60Hz, 11.1A 60Hz, 12.9A 60Hz, 11.2A 60Hz, 13.1ACat. No. AAH27026U AAH27123U AAH27016U AAH27113U
※ Permissible ambient Condition : Temperature 5℃ to 40℃,Maximumrelativehumidity80%※ All specifications are under ambient temperature 20℃(with refrigerator) / 25℃(without refrigerator), no load1) Technical data. (according to DIN 12880)
52
Accessories & Options for IncubatorsIncubators
Universal Platforms Wire Shelves Perforated Shelves
Wire Shelves Stainless steel and electro polished shelf system is removed easily without using tools for easy cleaning.
Cat. No. ModelsDescription
Included Maximum W×L (mm / inch)
EDA8136 IB-05G 2 8 366×316 / 14.4×12.4EDA8135 IB-15G 2 12 446×366 / 17.6×14.4EDA8137 IB-25G 2 12 576×419 / 22.7×16.5EDA8136 IB-01E 2 11 366×316 / 14.4×12.4EDA8220 IB-11E 2 14 466×490 / 17.6×19.3EDA8219 IB-21E 2 15 566×466 / 22.3×17.6EDA8219 IL-11 / 11A 2 12 566×466 / 22.3×17.6EDA8220 IL-21 / 21A 3 26 466×490 / 17.6×19.3EDA8223 ILP-02 1 6 195×310 / 7.7×12.2EDA8221 ILP-12 2 11 305×299 / 12.0×11.8
AAA31521 SIF-5000 / R 2 8 416×406 / 16.4×16.0AAA31522 SIF-6000 / R 2 11 516×506 / 20.3×19.9
Perforated Shelves Stainless steel shelf system is removed easily without using tools for easy cleaning.
Cat. No. ModelsDescription
Maximum W×L (mm / inch)
AAA12531 IB-05G 8 366×316 / 14.4×12.4AAA12532 IB-15G 12 446×366 / 17.6×14.4AAA12535 IB-25G 12 576×419 / 22.7×16.5AAA12531 IB-01E 11 366×316 / 14.4×12.4AAA22522 IB-11E 14 466×490 / 17.6×19.3AAA22521 IB-21E 15 566×466 / 22.3×17.6AAA22521 IL-11 / 11A 12 566×466 / 22.3×17.6AAA22522 IL-21 / 21A 26 466×490 / 17.6×19.3AAA24501 ILP-02 6 195×310 / 7.7×12.2AAA24502 ILP-12 11 305×299 / 12.0×11.8
Stacking Kits Stackable 2 steps up to maximize space efficiency with exclusive stacking kits. (Only for IB-G, IB-E series)
Cat. No. Models DescriptionAAA21521 IB-05G Stacking kits for stackable chambersAAA21522 IB-15G Stacking kits for stackable chambersAAA21523 IB-25G Stacking kits for stackable chambersAAA26501 IB-01E Stacking kits for stackable chambersAAA26502 IB-11E Stacking kits for stackable chambersAAA26503 IB-21E Stacking kits for stackable chambers
53
Accessories & Options for IncubatorsIncubators
Flask Clamps Plastic Clamps Funnel Clamps
Universal platforms & Flask clamps, Funnel clamps The universal platforms provide flexibility for mixing different sized assortment of test tubes and glassware on a single platform. Available in
different size assortment of clamps for Erlenmeyer flasks and Separatory funnels.
Description SI-300(R) SI-600(R) SI-971(R/F) SIF-5000(R) SIF-6000(R)
Universal platform Cat. No. AAA23501-V1 AAA23502-V1 AAA23503-V1 AAA31501-V1 AAA31502-V1Max. mountable fl ask clamps *
Cat. No. Erlenmeyer fl ask sizeSteel Plastic AAA23550 AAA30570 for 50mL 28 45 99 36 55AAA23551 AAA30571 for 100mL 24 36 74 28 44AAA23552 AAA30573 for 250mL 13 18 39 13 24AAA23556 AAA30574 for 300mL 13 18 39 13 24AAA23553 AAA30575 for 500mL 9 13 25 10 16AAA23554 AAA30576 for 1L 4 7 14 5 8AAA23555 AAA30577 for 2L 2 5 9 4 5AAA23557 - for 2.8L 1 2 6 2 4AAA23558 - for 4L - - 4 - 2AAA23559 - for 6L - - 4 - 2
Max. mountable funnel clamps *Cat. No. Separating funnel sizeAAA23562 for 250mL 4 6 11 4 6AAA23563 for 500mL 2 3 9 2 3AAA23564 for 1L - 2 5 - 2AAA23565 for 2L - - 4 - -
Dedicated platforms If using a single flask size only, the dedicated platforms provide maximum capacity, and come with clamps installed.
Provided standard clamp size are 250mL and 500mL, but possibly provide the other size of clamps also.
Cat. No. DescriptionAAA23611 AnuniversalplatformforSI-300serieswith250mLflaskclamps13eaAAA23612 AnuniversalplatformforSI-300serieswith500mLflaskclamps9eaAAA23621 AnuniversalplatformforSI-600serieswith250mLflaskclamps18eaAAA23622 AnuniversalplatformforSI-600serieswith500mLflaskclamps13eaAAA23631 AnuniversalplatformforIS-971serieswith250mLflaskclamps39eaAAA23632 AnuniversalplatformforIS-971serieswith500mLflaskclamps25eaAAA31551 AnuniversalplatformforSIF-5000serieswith250mLflaskclamps13eaAAA31552 AnuniversalplatformforSIF-5000serieswith500mLflaskclamps10eaAAA31561 AnuniversalplatformforSIF-6000serieswith250mLflaskclamps24eaAAA31562 AnuniversalplatformforSIF-6000serieswith500mLflaskclamps16ea
*Adedicatedplatformissoldwithsettingeachmax.mountableamountofflaskclampson.
54
Accessories & Options for IncubatorsIncubators
Rubber Mats Universal attachments Spring Wire Racks
Spring wire racks Ideal for holding a wide variety of tubes, flasks, and other glassware. All component are made of stainless steel.
Description SI-300(R) SI-600(R) SI-971(R/F) SIF-5000(R) SIF-6000(R)
Spring wire racks Cat. No. AAA23521 AAA23522 AAA23523 AAA31521 AAA31522
Max. inserting flask clampsErlenmeyer flask size
for 50mL 16 25 40 16 25for 100mL 9 16 28 9 16for 250ml 4 9 15 4 9for 300mL 4 9 15 4 9for 500ml 4 5 10 4 5
for 1L 2 4 8 2 4for 2L 1 2 4 1 2
for 2.8L 1 2 4 1 2
Rubber mats The non-skid rubber mats are designed for low-speed applications, allow for quick addition or removal of flasks, plates or tubes.
Models SI-300(R) SI-600(R) SI-971(R/F) SIF-5000(R) SIF-6000(R)
Cat. No. AAA23531 AAA23532 AAA23533 AAA31531 AAA31532
Universal attachments (Utility carriers) Several adjustable clamping bars to quickly secure a variety of glassware or tubes on non-skid rubber mat. Suitable for different sizes of flat
bottomed flasks.
Models SI-300(R) SI-600(R) SI-971(R/F) SIF-5000(R) SIF-6000(R)
Cat. No. AAA23531 AAA23532 AAA23533 AAA31531 AAA31532
Please visit .comFor further information on Jeio Tech´s Incubators products Informationisreadilyavailableonourwebsite.
55
Accessories & Options for IncubatorsIncubators
Test tube racks Highly durable stainless steel racks with adjustable angle and tube height support. Simply release and mount racks. Requires an universal
platform which are sold separately.
Cat. No. Description Mountable capacity of racks *AAA23581 for 86 test tubes 8mm dia. (0.3˝)
AAA23582 for 86 test tubes 10mm dia. (0.4˝)
AAA23583 for 58 test tubes 12mm dia. (0.5˝)
AAA23584 for 58 test tubes 14mm dia. (0.6˝)
AAA23585 for 32 test tubes 16mm dia. (0.7˝)
AAA23586 for 19 test tubes 25mm dia. (1.0˝)
AAA23594 for 10 test tubes 35mm dia. (1.4˝)
* No declination※ We can manufacture other size of test tube racks to meet your specific requirements. Contact us for details.
Microplate holders Available in three styles. A Tower type holder, two Flat types (small and large) and a Single type. The large flat holders will hold 4 standard or deep
well plates. The small flat holders will hold 3 standard or deep well plates. The single holders will hold only 1 standard or deep well plate.
Microplate holders Tower type Flat-A type (large) Flat-B type (small) Single typeCat. No. AAA23651 AAA23652 AAA23653 AAA23654
Max. mountable holdersSI-300(R) 5 - 2 7SI-600(R) 7 2 2 12
IS-971(R / F) 16 3 5 25SIF-5000 (R) 6 - 2 8SIF-6000 (R) 10 2 3 15
*Microplateholdersneedtobemountedonanuniversalplatformwhichissoldseparately.
Lab Sticker Alternative to flask clamps for securing vessels to a shaker platform the ideal way to secure containers such as bottles and dishes on the universal
platform is that cannot be held with conventional flask clamps. The lab sticker can be re-generated to a new condition by washing it with mild detergent and water. It cannot be used in water baths. For safe operation, suggest increasing the RPM gradually.
Description Lab StickerLab Sticker Cat. No. AAA30551
Size (mm / inch, W×D×H) 200×200×5 / 7.9×7.9×0.2
*LabStickerneedtobemountedonanuniversalplatformwhichissoldseparately.
SI-300(R) SI-600(R) IS-971(R/ F) SIF -5000 Series SIF-6000 Series
2EA 4EA 6EA 2 EA 4 EA
Test Tube Racks Microplate Holders Lab Sticker
Forced Convection Ovens.Natural Convection Ovens.Vacuum Ovens.
Ovens
Selection GuideForced Convection Ovens (Mechanical)
DescriptionOperating
Temp. Range(℃/℉)
ChamberVolume
(L /cu ft)
TemperatureFluctuationat 100℃ [±℃/℉]
TemperatureVariation
at 100℃ [±℃/℉]Page
General type
OF -02G Amb. +10 to 250 / Amb. +18 to 482
60 / 2.1 0.5 / 0.9 1.0 / 1.858OF -12G 102 / 3.6 0.6 / 1.08 1.3 / 2.3
OF -22G 151 / 5.3 0.8 / 1.44 1.7 / 3.1OF -300G
Amb. +10 to 200/ Amb.+18 to 392
314 / 11.0 0.2 / 0.36 0.9 / 1.6
60
OF -450G 450 / 15.9 0.1 / 0.18 0.7 / 1.3OF -750G 760 / 26.8 0.2 / 0.36 1.5 / 2.7OF -300H
Amb. +10 to 300/ Amb.+18 to 572
314 / 11.00.2 / 0.36
0.9 / 1.6OF -450H 450 / 15.9 0.8 / 1.4OF -750H 760 / 26.8 1.9 / 3.4
Economictype
OF -01EAmb. +10 to 220 / Amb. +18 to 428
52 / 1.8 0.8 / 1.44
3.3 / 5.9462OF -11E 100 / 3.5 3.3 / 5.94
OF -21E 150 / 5.3 2.3 / 4.14
Natural Convection Ovens (Gravity)
DescriptionOperating
Temp. Range(℃/℉)
ChamberVolume
(L /cu ft)
TemperatureFluctuationat 100℃ [±℃/℉]
TemperatureVariation
at 100℃ [±℃/℉]Page
General type
ON -02G Amb. +15 to 250 / Amb. +27 to 482
52 / 1.8 0.3 / 0.54
5.9 / 10.6263ON -12G 91 / 3.2 7.5 / 13.5
ON -22G 135 / 4.8 6.9 / 12.42
Economictype
ON -01E Amb. +15 to 220 / Amb. +27 to 428
52 / 1.8 0.3 / 0.54 6.5 / 11.764ON -11E 100 / 3.5 0.4 / 0.72 4.1 / 7.38
ON -21E 150 / 5.3 0.5 / 0.9 7.3 / 13.14
Vacuum Ovens
DescriptionOperating
Temp. Range(℃/℉)
ChamberVolume
(L /cu ft)
TemperatureFluctuationat 100℃[±℃/℉]
TemperatureVariation
at 100℃[±℃/℉]Page
VacuumOV -11 Amb. +5 to 250
/ Amb. +9 to 48228 / 1.0 0.1 / 0.18
3.7 / 6.66 66OV -12 65 / 2.3 0.3 / 0.54
Accessories & OptionsDescription Page
for Convection Ovens 65for Vacuum Ovens 67
Safety functions1) Self-protecting cut-off function and visual signals : - Over temperature safety function: shuts the
power that is being supplied to the heater and then the controller sequentially.
- 2 separate over-current fuses. (without large type)
2) Timer mode useful for delaying the start of a test or for stopping a test that has been running for a certain time :
- Integrated time setting: Delay ON/OFF [from 1 min 99hr 59 min]
- Power interruption setting: After a power interruption select automatic run or manual run.
3) Door-open warning alarm (excludes OV series) : - Intermittent audible tone and visual LED
warning alarms. - After 5 minutes of the door being open the
heater and fan will automatically stop to protect the user.
Optimum control performance1) Professional electronic and program control : - Microprocessor PID temperature control with
very simple calibration and auto-tuning feature. - Conveniently preset 3 most commonly used
temperature settings. - Switch from Celsius to Fahrenheit. (℃ or ℉)
2) HMI (Human Machine Interface) control display network system :
- Similar key arrangements to the temperature humidity chamber, bath, circulator, and shaker.
- User-friendly controls, splash proof / easy to clean keypad and clear LED display.
- Quick keypad lock key prevents accidental resetting of testing parameters.
Ideal construction1) High quality #304 grade stainless steel inner
chamber and dirt repellent powder coated exterior surface. (except for OV series)
2) Gasket minimizes heat loss and tightly seals the chamber door.
3) Fully insulated oven chamber prevents heat from escaping to the exterior surface.
4) Adjustable electro polished stainless steel shelv- ing provides air flow around samples for unifor-med tempering and allow for easy cleaning.
Technical Benefits
General ApplicationsGeneral applications
Forced, Nature convection ovens & VacuumOF-Series ON-Series OV-Series
General Aging and Curing •Agricultural Genetic • •Annealing • • •Asphalt Testing • •Conditioning • •
Contamination-Free storage of semiconductors and other sensitiveelectronic components
•
Desiccating •Digestion of Proteins and Starches •Drying of Plant Tissue •Drug Metabolism • •Electronic Burn-in • •Epoxy and Plastic Curing • •Fine Chemical Precipitation •General Baking • •General Heating • •Glassware Drying • •Ideal for General Drying •Life and Exposure Studies • •Ordnance Material Testing • •Out-gassing Solids and Liquids •Paper Drying • •Plating •Precise Moisture Determination • •Preheating • •Rubber Drying • •Serum Protein Analysis • •Silicon Wafer Drying •Stability and QC/ Batch Testing • •Sterilization • •Suspended Solids Evaluation • •Textile Drying • •Vacuum Embedding •Volatile Resins and Polymers Testing •Vulcanization Studies • •
58
Forced Convection OvensOvens
OF-22G with optional viewing window
Please visit .comFor further information on Jeio Tech´s Forced Convection Oven products Information is readily available on our website.
59
Forced Convection Ovens
Operating features • From +10℃ above room temperature to 250℃. • Microprocess PID control / Auto-tuning / Calibration. • Digital timer: 1 min ~ 99 hr 59 min, delayed ON / OFF. • Over temperature limit protection / door open alarm. • Conveniently preset 3 most commonly used temperature settings. • LED display (1℃ resolution) with a touch keypad. • RS-232 interface available.
Constructional features • Forced-air convection, noiseless sirocco fan which ensures proper
circulation and strong dispersion of air.
• Sample viewing window with threefold tempered glass window. (optional)
• An adjustable fan speed with an analog dial to prevent powdered samples from blowing away. (optional)
• Dual walled door opens 180 degrees and features a double latch door handle.
• Rounded inner chamber corners for easy cleaning and uniformed air flow.
• Corrosion-resistance incoloy sheath heated and stainless steel interior.
• Adjustable 2 top ventilation vents to control the inner air vapor circulation. (dia 38mm / 1.5inches)
OF-G series, quiet and with a strong air-flow for a high air exchange rate and short rise time that guarantees intensive drying performance, especially for material with high moisture content.
Intensive drying performance with a powerful air-flow.
Specifi cations & Ordering Informations
Model OF -02G OF -12G OF -22GChamber volume (L / cu ft) 60 / 2.1 102 / 3.6 151 / 5.3
TemperatureRange (℃ / ℉) Amb. +10 to 250 / Amb. +18 to 482Fluctuation 1) (±℃ / ℉) at 100℃ 0.5 / 0.9 0.6 / 1.08 0.8 / 1.44Variation 1) (±℃ / ℉) at 100℃ 1.0 / 1.8 1.3 / 2.3 1.7 / 3.1
Dimension(W×D×H)
Interior (mm / inch)400×360×420/ 15.7×14.2×16.5
480×410×520/ 18.9×16.1×20.5
550×460×600/ 22×18×23.6
Exterior (mm / inch)577×642×760 / 22.7×25.3×30
657×692×870 / 25.9×27.2×34.3
727×742×974/ 28.7×29.2×38.3
Net weight (Kg / lbs) 53 / 117 63 / 139 72.5 / 160Electrical Requirements (230V, 50 / 60Hz) 4.4A 6.1A 7.4ACat. No. AAH12155K AAH12165K AAH12175KElectrical Requirements (120V, 50 / 60Hz)) 6.8A 8.4A 10.1ACat. No. AAH12155U AAH12166U AAH12176U
1) Technical data (according to DIN 12880)
Convection pattern of OF-G series Included Accessories • 2 wire shelves Optional Accessories • Tempered viewing window
see page 65 • Fan speed adjuster • Perforated shelves
Ovens
60
OF-G / H series with optional viewing window
Forced Convection OvensOvens
OF-G / H (large) Display
Please visit .comFor further information on Jeio Tech´s Forced Convection Oven productsInformation is readily available on our website.
61
Forced Convection OvensOvens
The large high-performance oven types are designed for a wide variety of applications, even for intensive use. Also, the precise temperature control and powerful quickly heated air with evenly distributed air-flow, makes it possible for receiving immediate test results.
Available efficient large volume general purpose type ovens up to 760 liters and with fast drying performance. (200℃ or 300℃)
Convection pattern of OF-G / H series Included Accessories • 2 wire shelves (OF-300G / H) • 3 wire shelves (OF-450G / H, 750G / H) Optional Accessories • Tempered viewing window
see page 65 • Perforated shelves • Digital recorders
Operating features • 10℃ above room temperature to 200℃ (OF-G series) 10℃ above room temperature to 300℃ (OF-H series)
• Microprocess PID control/ Auto-tuning/ Calibration • Digital timer: 1 min ~ 99 hr 59 min, delayed ON/ OFF • Over-temperature limiter/ Door opening alarm • 3 different temperature values memorable • Selective Auto Run function after power recovery. • Digital LED display (1℃ resolution) using touch-sensitive keypads • RS-232 interface available
Constructional features • Forced-air convection with two noiseless sirocco fan which ensures
good mixing and strong dispersion • Optimized sample monitoring with threefold tempered safety
glass window (optional)
• Rounded inner chamber corners for easy cleaning and better air-flowing
• Corrosion-resistant incoloy sheath heating element and stainless steel interior
• Adjustable 2 side ventilation slides to control inner air, vapor circulation (dia 38mm/1.5″)
• 5 steps fan speed adjuster can be control inner circulation speed. • Casters easily make the unit mobile • Large size chamber with a maximum volume of 760L (28.8cu ft). • Recorder (optional) - 6-point dot type recorder with a digital display. - Thermal line type recorder
Specifi cations & Ordering Informations
Model OF-300G OF-450G OF-750G OF-300H OF-450H OF-750HChamber volume (L / cu ft) 314 / 11.0 450 / 15.9 760 / 26.8 314 / 11.0 450 / 15.9 760 / 26.8
TemperatureRange (℃ / ℉) Amb. +10 to 200 / Amb.+18 to 392 Amb. +10 to 300 / Amb.+18 to 572Fluctuation 1) (±℃ / ℉) at 100℃ 0.2 / 0.36 0.1 / 0.18 0.2 / 0.36 0.2 / 0.36 0.2 / 0.36 0.2 / 0.36Variation 1) (±℃ / ℉) at 100℃ 0.9 / 1.6 0.7 / 1.3 1.5 / 2.7 0.9 / 1.6 0.8 / 1.4 1.9 / 3.4
Dimension(W×D×H)
Interior (mm / inch)645×750×650 / 25.4×29.5×25.6
645×750×930 / 25.4×29.5×36.6
745×850×1200 / 29.3×33.5×47.2
645×750×650 / 25.4×29.5×25.6
645×750×930/ 25.4×29.5×36.6
745×850×1200 / 29.3×33.5×47.2
Exterior (mm / inch)835×1020×1225 / 32.9×40.2×48.2
835×1020×1505 / 32.9×40.2×59.3
955×1140×1775 / 37.6×44.9×69.9
835×1020×1225 / 32.9×40.2×48.2
835×1020×1505 / 32.9×40.2×59.3
955×1140×1775 / 37.6×44.9×69.9
Net weight (Kg / lbs) 175 / 386 210 / 463 280 / 617 210 / 463 250 / 551 335 / 739Electrical Requirements (230V, 1 ph, 50 / 60 Hz) 12.7A
Cat. No.Solid door type AAH18015 - - - - -Viewing window door type AAH18115 - - - - -
Electrical Requirements (230V, 3 ph, 50 / 60 Hz) 10.0A 13.8A 10.0A 13.8A 16.8A
Cat. No.Solid door type - AAH180213 AAH180313 AAH190113 AAH190213 AAH190313Viewing window door type - AAH181213 AAH181313 AAH191113 AAH191213 AAH191313
Electrical Requirements (380V, 3 ph, 50 / 60 Hz) 6.5A 8.8A 6.5A 8.8A 10.6A
Cat. No.Solid door type - AAH180214 AAH180314 AAH190114 AAH190214 AAH190314Viewing window door type - AAH181214 AAH181314 AAH191114 AAH191214 AAH191314
1) Technical data (according to DIN 12880)
62
Forced Convection Ovens - Economic type
Full feature performance for general purpose lab ovens.OF-E series feature a fast drying with vertical air-flow.
Operating features • From +10℃ above room temperature to 220℃. • Microprocess PID control / Auto-tuning / Calibration. • Digital timer: 1 min to 99 hr 59 min, delayed ON / OFF. • Over-temperature limit protection / Door opening alarm. • Conveniently preset 3 most commonly used temperature settings
without auto-tuning. • Digital LED display (1℃ resolution) with touch keypads.
Constructional features • Circular fan assisted forced-air convection provides a high unifor-
med drying performance.
• Moderately sized, spacious, and an easy to grip circular door handle.
• Corrosion-resistant incoloy sheath heater and stainless steel chamber.
• Two circular adjustable top slide vents helps to control inner air vapor circulation. (38mm / 1.5˝ in dia.)
OF-11E Included Accessories • 2 wire shelves Optional Accessories • Perforated shelves
see page 65
Ovens
Specifi cations & Ordering Informations
Model OF-01E OF-11E OF-21EChamber volume (L / cu ft) 52 / 1.8 100 / 3.5 150 / 5.3
TemperatureRange (℃ / ℉) Amb. +10 to 220 / Amb. +18 to 428Fluctuation 1) (±℃ / ℉) at 100℃ 0.4 / 0.72Variation 1) (±℃ / ℉) at 100℃ 3.3 / 5.94 3.3 / 5.94 2.3 / 4.14
Dimension(W×D×H)
Interior (mm / inch)375×370×370 14.8×14.6×14.6
455×430×51018×17×20
585×460×555 23×18.1×21.9
Exterior (mm / inch)530×535×737 20.9×21.1×29
610×595×877 24×23.4×34.5
740×625×922 29.1×24.6×36.3
Net weight (Kg / lbs) 36 / 79.4 47 / 103.6 59 / 130Electrical Requirements (230V, 50 / 60 Hz) 4.3A 6.0A 7.4ACat. No. AAH14012K AAH14022K AAH14032KElectrical Requirements (120V, 50 / 60 Hz) 6.8A 8.4A 10.1ACat. No. AAH14016U AAH14026U AAH14036U
1) Technical data. (according to DIN 12880)
63
Specifi cations & Ordering Informations
Model ON-02G ON-12G ON-22GChamber volume (L / cu ft) 52 / 1.8 91 / 3.2 135 / 4.8
TemperatureRange (℃ / ℉) Amb. +15 to 250 / Amb. +27 to 482Fluctuation 1) (±℃ / ℉) at 100℃ 0.3 / 0.54Variation 1) (±℃ / ℉) at 100℃ 5.9 / 10.62 7.5 / 13.5 6.9 / 12.42
Dimension(W×D×H)
Interior (mm / inch)400×360×365/ 15.7×14.2×14.4
480×410×465/ 18.9×16.1×18.3
610×460×485/ 24×18×19
Exterior (mm / inch)577×542×760/ 22.7×21.3×30
657×592×870/ 25.9×23.3×34.3
785×642×897/ 30.9×25.3×35.3
Net weight (Kg / lbs) 49 / 108 59 / 130 68 / 150Electrical Requirements (230V, 50 / 60 Hz) 4.3A 6.0A 7.4ACat. No. AAH11135K AAH11145K AAH11155KElectrical Requirements (120V, 50 / 60 Hz) 6.7A 8.3A 10.0ACat. No. AAH11136U AAH11146U AAH11156U
1) Technical data. (according to DIN 12880)
Natural Convection Ovens
Operating features • From +15℃ above room temperature to 250℃. • Microprocess PID control / Auto-tuning / Calibration. • Digital timer: 1 min to 99 hr 59 min, delayed ON / OFF. • Over temperature limit protection / Door opening alarm. • Conveniently preset 3 most commonly used temperature settings
without auto-tuning. • Digital LED display (1℃ resolution) with touch keypads.
Constructional features • Gravity-flow convection with vertical airflow for uniform sample
heating.
• Threefold tempered glass viewing window allows for easy moni-toring of samples. (optional)
• Fully insulated dual-wall door opens 180 degrees & featuring a pull down door handle.
• Rounded inner chamber corners for easy cleaning and better air-flowing.
• Corrosion-resistant incoloy sheath heater and stainless steel interior.
• Two circular adjustable top slide vents helps to control inner air vapor circulation. (38mm / 1.5˝ in dia.)
ON-G series is used for all sterilization and drying tasks that do not require high drying rates or special time requirements, ideal for drying applications requiring a gentle airflow.
Ideal for high temperature storage with user-friendly design
ON-22G with optional viewing window Included Accessories • 2 wire shelves Optional Accessories • Tempered viewing windows
see page 65 • Perforated shelves
Ovens
64
Natural Convection Ovens - Economic type
Full features performance for general purpose lab ovens.ON-E series is a economical warm storage up to 220℃.
Operating features • From +15℃ above room temperature to 220℃. • Microprocess PID control / Auto-tuning / Calibration. • Digital timer: 1 min to 99 hr 59 min, delayed ON / OFF. • Over temperature limit protection / Door opening alarm. • Conveniently preset 3 most commonly used temperature settings
without auto-tuning • Digital LED display (1℃ resolution) with touch keypads.
Constructional features • Gravity-flow convection generates a vertical airflow of heat for a
uniformed heating of samples.
• Moderately sized, an easy to clean spacious chamber, and an easy to grip circular door handle.
• Corrosion-resistant incoloy sheath heater and stainless steel chamber.
• Two circular adjustable top slide vents helps to control inner air vapor circulation. (38mm / 1.5˝ in dia.)
ON-11E Included Accessories • 2 wire shelves Optional Accessories • Perforated shelves
see page 65
Ovens
Specifi cations & Ordering Informations
Model ON-01E ON-11E ON-21EChamber volume (L / cu ft) 52 / 1.8 100 / 3.5 150 / 5.3
TemperatureRange (℃ / ℉) Amb. +15 to 220 / Amb. +27 to 428Fluctuation 1) (±℃ / ℉) at 100℃ 0.3 / 0.54 0.4 / 0.72 0.5 / 0.9Variation 1) (±℃ / ℉) at 100℃ 6.5 / 11.7 4.1 / 7.38 7.3 / 13.14
Dimension(W×D×H)
Interior (mm / inch)375×370×370 / 14.8×14.6×14.6
455×430×510 / 18×17×20
585×460×555 / 23×18.1×21.9
Exterior (mm / inch)530×535×737 / 20.9×21.1×29
610×595×877 / 24×23.4×34.5
740×625×922 / 29.1×24.6×36.3
Net weight (Kg / lbs) 34 / 75 46 / 101.4 59 / 130Electrical Requirements (230V, 50 / 60 Hz) 4.3A 6.0A 7.4ACat. No. AAH15015K AAH15025K AAH15035KElectrical Requirements (120V, 50 / 60 Hz) 6.7A 8.3A 10.0ACat. No. AAH15016U AAH15026U AAH15036U
1) Technical data. (according to DIN 12880)
65
Wire Shelves Stainless steel and electro polished shelf system is removed easily without using tools for easy cleaning.
ModelsDescription
Cat. No.Included Maximum W×L (mm / inch)
OF-02G 2 8 366×316 / 14.4×12.4 EDA8136OF-12G 2 12 446×366 / 17.6×14.4 EDA8135OF-22G 2 14 516×416 / 20.3×16.4 EDA8134OF / ON-01E 2 10 366×316 / 14.4×12.4 EDA8136OF / ON-11E 2 14 446×366 / 17.6×14.4 EDA8135OF / ON-21E 2 15 576×419 / 22.7×16.5 EDA8137OF-300G / H 2 17 708×608 / 27.9×23.9 RTD1196OF-450G / H 3 26 708×608 / 27.9×23.9 RTD1196OF-750G / H 3 35 708×808 / 27.9×31.8 RTD1197ON-02G 2 8 366×316 / 14.4×12.4 EDA8136ON-12G 2 12 446×366 / 17.6×14.4 EDA8135ON-22G 2 12 576×419 / 22.7×16.5 EDA8137
Perforated Shelves Stainless steel shelf system is removed easily without using tools for easy cleaning.
ModelsDescription
Cat. No.Maximum W×L (mm / inch)
OF-02G 8 366×316 / 14.4×12.4 AAA12531OF-12G 12 446×366 / 17.6×14.4 AAA12532OF-22G 14 516×416 / 20.3×16.4 AAA12533OF / ON-01E 10 365×310 / 14.4×12.4 AAA12531OF / ON-11E 14 445×360 / 17.6×14.4 AAA12532OF / ON-21E 15 575×410 / 22.7×16.5 AAA12535OF-300G / H 17 708×608 / 27.9×23.9 AAA80604-2OF-450G / H 26 708×608 / 27.9×23.9 AAA80604-2OF-750G / H 35 708×808 / 27.9×31.8 AAA80604-3ON-02G 8 366×316 / 14.4×12.4 AAA12531ON-12G 12 446×366 / 17.6×14.4 AAA12532ON-22G 12 576×419 / 22.7×16.5 AAA12535
Recorders Easy recognizable digital recorders for efficient temperature indicating.
Models Description Cat. No.
OF-300, 450, 750 G/HRecorder (6 Point) AAA8T500Recorder (Thermal Line type) AAAE1503
Tempered Viewing Windows Optimized sample monitoring with threefold, tempered safety glass window. (Only for OF-G, ON-G series)
ModelsDescription
Cat. No.Thickness, W×L (mm / inch)
OF / ON-02G 5, 150×280 / 0.2, 5.9×11 AAA12611OF / ON-12G, 22G 5, 150×380 / 0.2, 5.9×15.0 AAA12612
Fan-Speed Adjuster Adjustable inner air circulation speed, which protects spreading out powder sample.
(Only for OF-G series)
Models Description Cat. No.
F - 02G, 12G, 22G Analog dial control AAA12701
※ In addition to providing standard accessories, we will manufacture customized accessories to meet your specific requirements. Contact us for details.
Wire Shelves
Perforated Shelves
Tempered Viewing Windows
Fan Speed Adjuster
Accessories & Options for OvensOvens
66
Vacuum Ovens
Optimal vacuum oven with a wide temperature range for various test applications.OV series ovens are ideal for separating solvents from solutions without using high temperature drying and for drying solvents with high boiling points in a vacuum ovens reduces the boiling point of the solvent to make drying easy.
Operating features • From +5℃ above room temperature to 250℃. • Vacuum range: 0 to 0.1MPa. (analog vacuum gauge) • Microprocess PID control / Auto-tuning / Calibration. • Digital timer: 1 min to 99 hr 59 min, delayed ON / OFF. • Over temperature limit protection / Door opening alarm. • Conveniently preset 3 most commonly used temperature settings
without auto-tuning. • Digital LED display (1℃ resolution) with touch keypads. • RS-232 interface available.
Constructional features • Separate vacuum and vent ports: the narrow vent line controls the
vacuum rate and inert. (wider the vacuum line, the faster the vacuum is produced.)
• Tight gasket seal and push-button latch.
• Block type heater distributes heat evenly from the chamber exterior to the anodized.
• Heat tempered spring load glass door gives a tight vacuum seal and convenient for continuous monitoring of samples.
• Moderately sized oven with user-friendly all-in-one control panel.
• Upon request available with Viton (fluorine rubber) door gasket.(optional)
OV-11 Included Accessories • Plate shelve, 3.0mm (0.12˝) :
2 for OV-11 / 3 for OV-12. Optional Accessorie • Safety cover.
see page 67 • Viton gasket. • Vacuum pumps and Oil mist trap. • Cold trap baths and U-type glass trap.
Ovens
Specifications & Ordering Informations
Model OV-11 OV-12Chamber volume (L / cu ft) 28 / 1.0 65 / 2.3Vacuum range 0~0.1MPa, AnalogNozzle size (mm / inch) Vacuum Ø10 / 0.4, Vent Ø10 / 0.4
TemperatureRange (℃ / ℉) Amb. +5 to 250 / Amb. +9 to 482Fluctuation 1) (±℃ / ℉) at 100℃ 0.1 / 0.18 0.3 / 0.54Variation 1) (±℃ / ℉) at 100℃ 3.7 / 6.66
Dimension(W×D×H)
Interior (mm / inch)302×305×302 / 11.9×12×11.9
402×405×402/ 15.8×15.9×15.8
Exterior (mm / inch)680×453×495 / 26.8×17.8×19.5
780×557×595/ 15.8×15.9×15.8
Net weight (Kg / lbs) 63 / 139 103 / 227Electrical Requirements (120V, 50 / 60 Hz) 5.3A 6.1ACat. No. AAH13115K AAH13125KElectrical Requirements (230V, 50 / 60 Hz) 10A 11.7ACat. No. AAH13116U AAH13126U
1) Technical data. (according to DIN 12880)
67
Safety Covers
Viton Gaskets
Vacuum Pumps
Cold Trap Baths
Accessories & Options for Vacuum OvensOvens
(Organization chart for use of Vacuum oven with Pump and Cold trap bath)
Safety Covers Netted steel frame and polycarbonate sheet covering prevents the glass door from exploding.
Models Description Cat. No.OV-11 Safety Cover AAA13603OV-12 Safety Cover AAA13604
Gaskets Upon request available with Viton (fluorine rubber) door gasket.
Models Description Cat. No.
OV-11Silicone Gasket FAA5146Viton (Fluorine rubber) Gasket FAA5187
OV-12Silicone Gasket FAA5147Viton (Fluorine rubber) Gasket FAA5188
Related products for Vacuum Ovens
Vacuum Pumps Rotary vacuum pump equipped with direct connect oil seal prevents air reflux, essentially
used with vacuum ovens to achieve a higher level of vacuum pressure. Oil mist trap, an optional feature, prevents oil in-flow (refer to page. 69 for more specific information)
Models Electrical Requirements Cat. No.
MVP-6230V, 50 / 60Hz BEH73005K120V, 60Hz BEH73006K
Related accessory Oil Mist Trap BEH73501
Cold Trap Baths Preventing vacuum pumps in a condition of vacuuming as a cold trap to prevent vapors from
a vacuum pump Included 2 U-type glass traps. (refer to page. 18 for more specific information)
Models Description Cat. No.
CTB-10230V, 60Hz AAH62011K230V, 50Hz AAH62012K
Related accessory U-type Glass Trap AAA62501
※ In addition to providing standard accessories, we will manufacture customized accessories to meet your specific requirements. Contact us.
Electrical Aspirator Pumps.Rotary Vacuum Pumps.
Pumps
Electrical Aspirator Pumps
VE-11 with optional vacuum gauge / regulator
Portable dual-channel, water-jet aspirator pumps.
VE-11 creates a vacuum using an aspirator pump that is dependent on the vapor pressure of water, a function of temperature. Ideal for rotary vacuum evaporators, decompressing distillatories, vacuum dryers, and vacuum filtering units.
Features • Built-in circulating pump and water tank makes this unit portable
and eliminates water waste.
• Circulating pump continuously forces water quietly across a set of aspirators, and therefore clean and efficient.
• Included (2) metal aspirators to create a vacuum with a built-in check valve to prevent backflow of water into the aspirator pump.
• Submerged parts: Type 304 stainless steel, polypropylene silicone, and nickel-coated brass.
• Tank features a drain port and spigot for easy water changes.
• Unlike other vacuum pumps the VE-11 can suck a little bit of solvent. (water)
Included Accessories • Tank / Aspirating pump / Tank closure.
• Two aspirators.
• Two ø6mm (0.02˝) silicone rubber tube 20cm (0.7 ft) in length and an additional ø6mm (0.02˝) silicone rubber tube 100cm (3.3 ft)in length.
69
Aspirators
Cooling coil
MVP-6 Rotary Vacuum PumpOptional Accessories •Oilmisttraps(TMF -12)
Rotary Vacuum Pumps
Optional Accessories • Vacuum gauge / regulator: to monitor and control the vacuum
pressure. (between 0.0267~0.0998MPa / 7.9~29.5˝ Hg)
• Cooling coil: to prevent vacuum from decreasing due to tempe-rature increase.
• Aspirators: nickel-coated brass, with inner ball, and check valve to prevent backflow of water.
Description Cat. No.Vacuum gauge / regulator AAA71531Cooling coil AAH71501Aspirator AAH71121
Specifications & Ordering Informations Model VE-11
Bath volume (L / cu ft) 9.5 / 0.3Max. vacuum (Mpa / Hg) 0.0998 / 29.5”Free-air capacity 18L/minute(0.6cfm)×2ea
MaterialBath PolypropyleneAspirator Nickel-coatedbrass×2ea
Dimensions
Bath internal (W×L , D) (mm / inch) 298×210, 227 / 11.7×8.3 ,8.9Overall (W×L×H) (mm / inch) 330×265×390 / 13.0×10.4×15.4Inhale nozzle externalØ9.5mm(0.4”)×2eaDrain cook, over flow nozzle (mm / inch) Ø17.0/0.7Net weight (kg / lbs) 5.7 / 12.6
Electrical Requirements 230V / 50,60Hz / 0.7A 120V / 50,60Hz / 1.4A Cat. No. AAH71015K AAH71016U
Feature • Rotary vacuum pump equipped with direct connect oil seal
prevents air reflux, essentially used with vacuum ovens to achieve a higher level of vacuum pressure.
• Oil mist trap, an optional feature, prevents oil in-flow.
Specifications & Ordering InformationsModel MVP - 6
Pumping speed (L / min) 100Msx. pressure (Pa) 6.7×10 -2
Motor power (W) 400Motor speed (rpm) 1750Recommended oil (L) 1.1Inlet / Outlet port (DN) 25KFWeight (Kg) 22.5 (49.6lb)Electrical Requirement 230V, 50 / 60HzCat. No. BEH73005KElectrical Requirement 120V, 60HzCat. No. BEH73006U
Accessories Model Electrical Requirement Cat. No.
Related accessory OilMistTrap BEH73501
Recirculating Coolers - Basic type
Low Temp. Recirculating Coolers - General Type
Low Temp. Recirculating Coolers - Intelligent type
Recirculating Coolers(Chillers)
Selection GuideRecirculating Cooler
DescriptionWorking Temp.
Range (℃ / ℉)
Cooling capacity at 10℃ [Kw]
Pump (50Hz)
PageMax. flow rate (L / min, gal / min)
Max. pressure (bar / psi)
Basic type
HX-20
+3 to 40 / +37.4 to 104
1.438 / 10.03 1.58 / 22.92
72
HX-25 1.7HX-20H 1.4
45 / 11.89 4.3 / 62.37HX-25 H 1.7HX-35H 3.1HX-45H 3.6HX-55H 5.1
General type (Low temp.)
HL-05
-20 to 40 / -4 to 104
0.50
50 / 13.2 1.0 / 14.5
74
HL-10 0.60 HL-15 1.15 HL-20 1.50 HL-15H 1.15
40 / 10.57 2.8 / 40.6HL-20H 1.15 HL-25H 1.80 HL-35H 2.30 HL-45H 4.50
70 / 18.49 6 / 87.0HL-55H 6.00
Intelligent type (Low temp.)
HS-15
-20 to 40 / -4 to 104
1.15
40 / 10.57 2.8 / 40.6
76
HS-20 1.50 HS-25 1.80 HS-35 2.30 HS-45 4.50 HS-55 6.00 HS-25H 1.80
70 / 18.49 6 / 87.0HS-35H 2.30 HS-45H 4.50 HS-55H 6.00
Accessories & OptionsDescription Page
for Recirculating Cooler 78 - 79
Safety functions1) Self - protecting cut-off function and signal : - For over temperature, the power supply is
automatically cut from the heater and controller systematically before the unit shuts down.
- Over - current Circuit breaker for user safety.
2) Low fluid level and dry - running protection : - Intermittent tone alert sounds and optical
signals alarms display on the control panel.
3) Double service valve provided to prevent ref-rigerant leakage.
Optimum control performance1) Functional LCD (resolution 0.1℃) keypad type
display : Designed to simplify operation with a VFD touch screen type display (HL / HS-series)
- Self-diagnostic function identifies equipment errors.
- Recognizable and convenient keypad . - Clear and easy-to-use LCD display.
2) Bright LED water level indicator
3) Pump pressure gauge
4) Run, compressing, pumping visual indicator
5) Eco-friendly R-404A or R507 refrigerant
6) Hot gas by-pass (only HL/HS series)
Ideal construction1) High quality #304 grade stainless steel inner
chamber and dirt repellent powder coated external surface.
2) Stainless steel submerged parts are resistant to corrosion against all usual bath fluids.
3) Pump pressure can be controlled using a bypass function. (only for HX-H type)
4) Removable gridded vent for reducing condenser contamination and to facilitate cleanliness.
5) A wide (Ø120mm / 4.72″) solution inlet is for easy and safe pouring of solution.
6) Wheels allow for easy mobility.
7) Computer Interface. (only HS series)
8) Warning alarm/monitoring system. - Over temperature. - Lack of bath solutions.
9) Pressure gauge comes standard with recirculating units to provide fluid system diagnostics at a glance and for observing the pump pressure.
Technical Benefits
General ApplicationsGeneral Applications
Recirculating CoolersHX-Series HL/HS-Series
AAS • •Autoclaves • •Calorimeters •CCM cameras •Combinatorial chemistry •Cooling of peltier elements •Diffusion pumps • •Distillation apparatus • •Dosing and gluing techniques •Drying of gas •Electrophoresis chambers • •Gas chromatographs •General industries • •General laboratory apparatus • •Lasers •Mass spectrometers • •Mills and kneaders •NMR • •Pilot plants • •Plastic industries • •Reaction vessels • •Rotary evaporators • •SEM •Semiconductor industries • •Soxhlet installation •Spectrometers • •Vacuum systems • •
* General purpose use and applications.
72
Recirculating Coolers - Basic type
Providing a constant temperature control and high cooling efficiency.
Operating cost can be reduced by using the recirculator for cooling water. It is eco-friendly and reduces energy consumption.
Operating features • Control temperature range is from 3℃~40℃.
• Clear and easy-to-use LCD display. (resolution 0.1℃)
• Bright LED water level indicator can be seen from a distance.
• Low fluid level and dry-running protection when triggered shows an error symbol on the display and an audible buzzer sound.
• If the equipment operates at 40℃ or above due to the external environment, user can simply identify the error with a visual signal or an audible buzzer sound.
• Pump pressure can be controlled using a by-pass function. (only H type)
Constructional features • The refrigerating system is designed to reduce energy consumption
and to maximize in refrigerating efficiency.
• Eco-friendly R-404A refrigerant is used to prevent environmental pollution. Double service valve is used to prevent refrigerant leakage.
• Removable gridded vent for reducing condenser contamination and to facilitate cleanliness.
• A plastic solution inlet is for easy and safe pouring of solution into the chiller unit.
• Pressure gauge comes standard with chiller units to provide fluid system diagnostics at a glance and for observing the pump pressure.
• Wheels allow for easy mobility throughout the lab.
• The beautifully designed chiller is compact.
• Different types of pumps and valves come standard with the chiller to provide versatility.
• Variety of accessories are available to meet user’s different lab environment needs. (refer to accessories)
Testing in accordance with DIN EN 12876Optional Accessories •Fittings,Adapters
see page 78-79 •Tubing,Insulations •Tubeclamps •Bathfluid
Recirculating Coolers (Chillers)
LCD Display
Pressure Gauge Level Indicator
73
Pumping Capacities (Bath fluid : water)
Centrifugal Magnetic
Specifications & Ordering Informations
Model HX-20 HX-25 HX-20H HX-25H HX-35H HX-45H HX-55H
Temperature1)
(bath fluid : water)
Working temperature range (℃ / ℉)
+3 to 40 / +37.4 to 104
Temperature stability at 15℃ (±℃ / ℉)
1 / 1.8
Cooling capacity (bath fluid : water)
at20℃ (kW) 1.9 2.4 1.9 2.4 3.6 4.7 7.1at10℃ (kW) 1.4 1.7 1.4 1.7 3.1 3.6 5.1at5℃ (kW) 1.0 1.4 1.0 1.4 2.4 2.9 4.2
PumpMax. flow rate(L / min, gal / min) 38 / 10.03 38 / 10.03 45 / 11.89 45 / 11.89 45 / 11.89 45 / 11.89 45 / 11.89
Max. pressure (bar / psi) 1.58 / 22.92 1.58 / 22.92 4.3 / 62.37 4.3 /62.37 4.3 /62.37 4.3 / 62.37 4.3 / 62.37
Dimension
Max. filling capacity(L / cu ft) 35 / 1.24 35 / 1.24 35 / 1.24 35 / 1.24 45 / 1.59 45 / 1.59 45 / 1.59
For tubing dia(mm / inch) 20 / 0.79 20 / 0.79 20 / 0.79 20 / 0.79 20 / 0.79 20 / 0.79 20 / 0.79
Overall(W×L×H, mm / inch)
610×670×970 /24.0×26.4×38.2
740×730×1065 /29.1×28.7×41.9
Net weight (kg / lbs) 93 / 205 101 / 223 97 / 214 105 / 231 120 / 265 130 / 287 140 / 309Electrical Requirements (220V, 60Hz) 8.5A 9A 9A 9.5A 15ACat. No. AAA64011 AAA64021 AAA64111 AAA64121 AAA64131 - -Electrical Requirements (230V, 50Hz) 7A 7.6A 10.5A 11A 17ACat. No. AAH64012K AAH64022K AAH64112K AAH64122K AAH64132K - -Electrical Requirements (120V, 60Hz)
Cat. No. AAH64013U AAH64023U - - - - -Electrical Requirements (380V, 60Hz) 10A 11.5ACat. No. - - - - - AAA64149 AAA64159Electrical Requirements (380V, 50Hz) 7A 8.5ACat. No. - - - - - AAH64148K AAH64158K
1)Technicaldata(accordingtoDIN12876)
*Abovespeificationvalueisrecordedby50Hz.2)OnlyHX-45H,55Hisrecordedby380V,60Hz.
*Theperformancevaluesreferto+20℃(68℉) ambienttemperature.*Productperformancemaybeaffectedbyambienttemperatures.
Recirculating Coolers - Basic type
Recirculating Coolers (Chillers)
74
Low Temp. Recirculating Coolers - General Type
Powerful recirculating coolers, the HL series provide a wide range of cooling capacities with temperature reliability. Innovative control system, with a dynamic pumping capacity, and ideal for external temperature applications. Broad range of models to choose from based on working temperature range.
Testing in accordance with DIN EN 12876Optional Accessories •Fittings,Adapters
see page 78-79 •Tubing,Insulations •Tubeclamps •Bathfluid
Recirculating Coolers (Chillers)
Operating features • Temperature range is from -20℃~40℃.
• Bright LED water level indicator can be easily identified.
• Low fluid level and dry-running protection when triggered shows an error symbol on the display and an audible sound.
• If the equipment operates at 40℃ or above due to the external environment, user can simply identify the error with a visual or an audible sound.
• Designed to simplify operation with a touch screen type display. - Easy-to-read VFD display with interactive touch keys. - Setting and resolution indication 0.1℃/℉. - Quick keypad lock prevents accidental parameter changes. - Signal indicator for operation status.
Constructional features • The refrigerating system is designed to reduce energy consumption
and to maximize in refrigerating efficiency.
• Eco-friendly R-404A / R507 refrigerant is used to prevent enviro-nmental pollution. Double service valve is used to prevent refrigerant leakage.
• Removable gridded vent for reducing condenser contamination and to facilitate cleanliness.
• A wide (Ø120mm / 4.72″) solution inlet is for easy and safe pouring of solution into the recirculating cooler.
• Pressure gauge comes standard for observing the pump pressure
• The refrigeration system can be observed easily to diagnostic at a glance by high / low pressure gauges. (HL-25H, 35H, 45H, 55H models)
• Wheels allow for easy mobility.
• The beautifully designed and compact.
• Different types of pumps come standard with the recirculating cooler to provide versatility.
• Warning alarm/monitoring system. - Over temperature. - Lack of bath solutions.
• Variety of accessories is available to meet user’s different lab environment needs. (Refer to accessories)
75
Pumping Capacities (Bath fluid : Ethtylene glycol mix 1:1 Water)
Submersible pump
0
0.6
0.4
0.2
0.8
1.0
1.2
1.4
10 20 30 40 50 60
Flow rate (L/min)
60Hz
60Hz
50Hz
50Hz
50Hz, 60Hz
pressure (Bar)
0
1.0
2.0
3.0
4.0
5.0
6.0
10 20 30 40 50 60 70
Flow rate (L/min)
pressure (Bar)
0
1.0
2.0
3.0
4.0
5.0
6.0
10 20 30 40 6050 70
Flow rate (L/min)
pressure (Bar)
0
0.6
0.4
0.2
0.8
1.0
1.2
1.4
10 20 30 40 50 60
Flow rate (L/min)
60Hz
60Hz
50Hz
50Hz
50Hz, 60Hz
pressure (Bar)
0
1.0
2.0
3.0
4.0
5.0
6.0
10 20 30 40 50 60 70
Flow rate (L/min)
pressure (Bar)
0
1.0
2.0
3.0
4.0
5.0
6.0
10 20 30 40 6050 70
Flow rate (L/min)
pressure (Bar)
0
0.6
0.4
0.2
0.8
1.0
1.2
1.4
10 20 30 40 50 60
Flow rate (L/min)
60Hz
60Hz
50Hz
50Hz
50Hz, 60Hz
pressure (Bar)
0
1.0
2.0
3.0
4.0
5.0
6.0
10 20 30 40 50 60 70
Flow rate (L/min)
pressure (Bar)
0
1.0
2.0
3.0
4.0
5.0
6.0
10 20 30 40 6050 70
Flow rate (L/min)
pressure (Bar)
Specifications & Ordering Informations
Model HL-05 HL-10 HL-15 HL-20 HL-15H HL-20H HL-25H HL-35H HL-45H 2) HL-55H 2)
Temperature 1) (bath fluid : Ethtylene glycol mix 1:1 Water)
Working Temperature range (℃ / ℉)
-20 to 40 / -4 to 104
Temperature stability at 15℃, (±℃ / ℉)
1 / 1.8
Cooling capacity (bath fluid : Ethtylene glycol mix 1:1 Water)
at 20℃ (kw) 0.60 0.70 1.45 1.80 1.45 1.80 2.50 3.30 6.50 7.10
at 10℃ (kw) 0.50 0.60 1.15 1.50 1.15 1.50 1.80 2.30 4.50 6.00
at 0℃ (kw) 0.35 0.42 0.86 1.15 0.86 1.15 1.10 1.70 3.00 4.10
at -10℃ (kw) 0.18 0.32 0.62 0.85 0.62 0.85 0.65 1.00 2.10 2.50
at -20℃ (kw) 0.04 0.14 0.30 0.40 0.30 0.40 0.40 0.55 1.20 1.50
Pump
Max. flow rate (L / min, gal / min) 50 / 13.2 40 / 10.57 70 / 18.49
Max. pressure (bar / psi) 1.0 / 14.5 2.8 / 40.6 6 / 87.0
Dimension
Max,. filling capacity (L, cu ft) 10 / 0.35 15 / 0.53 15 / 0.53 25 / 0.88 40 /1.41
For tubing dia (mm / inch) 12.7 / 0.5 20 / 0.79
Overall (WxLxH, mm / inch)
400×545×690 / 15.7×21.5×27.2
510×640×715 / 20.1×25.2×28.1
510×640×715 / 20.1×25.2×28.1
550×850×1100 / 21.7×33.5×43.3
600×1000×1300 / 23.6×39.4×39.4
Net weight (kg / Ibs)62.85 / 138.6
64.85/ 143.0
86.5 / 190.7
87.35 /192.9
91.8 / 202.4
92.65 / 204.3
141.3 / 310.9
146.3 /321.9
171 ±10 /377 ±22
176 ±10 / 388 ±10
Electric requirement (230V, 60Hz) 5.0A 5.5A 6.5A 7.5A 6.5A 7.5A 9.5A 13.5A
Cat. No. AAH65001 AAH65011 AAH65021 AAH65031 AAH65121 AAH65131 AAH65141 AAH65151 - -
Electric requirement (230V, 50Hz) 4.5A 5.0A 6.0A 7.0A 6.0A 7.0A 7.5A 12.5A
Cat. No. AAH65002 AAH65012 AAH65022 AAH65032 AAH65122 AAH65132 AAH65142 AAH65152 - -
Electric requirement (120V, 60Hz) 10.0A 11.0A 13.0A 15.0A
Cat. No. AAH65003 AAH65013 AAH65023 AAH65033 - - - - - -
Electric requirement (380V, 60Hz) 5.5A 7.0A
Cat. No. - - - - - - - - AAH65169 AAH65179
Electric requirement (380V, 50Hz) 5.0A 6.0A
Cat. No. - - - - - - - - AAH65168 AAH65178
1)Technicaldata(accordingtoDIN12876)
*Abovespeificationvalueisrecordedby50Hz.2)OnlyHL-45H,55Hisrecordedby380V,60Hz.
*Theperformancevaluesreferto+20℃(68℉) ambienttemperature.*Productperformancemaybeaffectedbyambienttemperatures.
Low Temp. Recirculating Coolers - General Type
Recirculating Coolers (Chillers)
• HL - 05, 10, 15, 20 models • HL - 15H, 20H, 25H, 35H models • HL - 45H, 55H models
76
Low Temp. Recirculating Coolers - Intelligent Type
Adjustable, precise PID temperature controller beneficial for various cooling tasks, for use in the science, research, and industrial laboratories.Innovative and exclusive controller can be adjusted the cooling capacity from 1% to 100%
Operating features • Temperature range is from -20℃~40℃. • As an option an external sensor can be directly installed into the
cooling circuit for monitoring and regulating of temperatures. • Precise temperature stability ± 0.2℃ (at 15℃) without heater. • Bright LED water level indicator can be easily identified. • Low fluid level and dry-running protection when triggered shows
an error symbol on the display and an audible sound. • If the equipment operates at 40℃ or above due to the external
environment, user can simply identify the error with a visual or an audible sound.
• Designed to simplify operation with a touch screen type display. - Easy-to-read VFD display with interactive touch keys - Setting and resolution indication 0.1℃/℉ - Quick keypad lock prevents accidental parameter changes - Signal indicator for operation status
Constructional features • The refrigerating system is designed to reduce energy consumption
and to maximize in refrigerating efficiency. • Available external temperature sensor (Pt 100) for measured value • Computer Interface -Software provided -Save data in excel format -Storage of program information, backup of value settings/recovery,
and temperature values -RS-232C comes standard • Eco-friendly R-404A / R507 refrigerant is used to prevent enviro-
nmental pollution. Double service valve is used to prevent refrigerant leakage.
• Removable gridded vent for reducing condenser contamination and to facilitate cleanliness.
• A wide (Ø120mm / 4.72″) solution inlet is for easy and safe pouring of solution into the recirculating cooler.
• Pressure gauge comes standard for observing the pump pressure • The refrigeration system can be observed easily to diagnostic at a
glance by high / low pressure gauges. (HL-25H, 35H, 45H, 55H models)
• The beautifully designed and compact. • Different types of pumps come standard with the recirculating
cooler to provide versatility • Warning alarm/monitoring system - Over temperature - Lack of bath solutions
• Variety of accessories is available to meet user’s different lab env-ironment needs. (Refer to accessories)
Recirculating Coolers (Chillers)
Digital controllor
RS-232 Serial port & etc
77
0 10 20 30 40 50
Flow rate (L/min)
50Hz, 60Hz 50Hz, 60Hz
pressure (Bar)
0
1.0
2.0
3.0
4.0
5.0
6.0
1.0
2.0
3.0
4.0
5.0
6.0
10 20 30 40 50 60 70
Flow rate (L/min)
pressure (Bar)
0
1.0
2.0
3.0
4.0
5.0
6.0
10 20 30 40 6050 70
Flow rate (L/min)
pressure (Bar)
0 10 20 30 40 50
Flow rate (L/min)
50Hz, 60Hz 50Hz, 60Hz
pressure (Bar)
0
1.0
2.0
3.0
4.0
5.0
6.0
1.0
2.0
3.0
4.0
5.0
6.0
10 20 30 40 50 60 70
Flow rate (L/min)
pressure (Bar)
0
1.0
2.0
3.0
4.0
5.0
6.0
10 20 30 40 6050 70
Flow rate (L/min)
pressure (Bar)
Pumping Capacities (Bath fluid : water)
Submersible pump
Specifications & Ordering Informations
Model HS-15 HS-20 HS-25 HS-35 HS-45 HS-55 HS-25H HS-35H HS-45H HS-55H
Temperature 1) (bath fluid : Ethtylene glycol mix 1:1 Water)
Working Temperature range (℃ / ℉)
-20 to 40 / -4 to 104
Temperature stability at 15℃, (±℃ / ℉)
0.2 / 0.36
Cooling capacity (bath fluid : Ethtylene glycol mix 1:1 Water)
at 20℃ (kw) 1.45 1.80 2.50 3.30 6.50 7.10 2.50 3.30 6.50 7.10
at 10℃ (kw) 1.15 1.50 1.80 2.30 4.50 6.00 1.80 2.30 4.50 6.00
at 0℃ (kw) 0.86 1.15 1.10 1.70 3.00 4.10 1.10 1.70 3.00 4.10
at -10℃ (kw) 0.62 0.85 0.65 1.00 2.10 2.50 0.65 1.00 2.10 2.50
at -20℃ (kw) 0.30 0.40 0.40 0.55 1.20 1.50 0.40 0.55 1.20 1.50
Pump
Max. flow rate (L / min, gal / min) 40 / 10.57 70 / 18.49
Max. pressure (bar / psi) 3.3 / 47.86 6 / 87.0
Dimension
Max. filling capacity (L, cu ft) 15 / 0.53 25 / 0.88 40 / 1.41 25 / 0.88 40 / 1.41
For tubing dia (mm / inch) 20 / 0.79
Overall (W×L×H, mm / inch)
510×640×715 / 20.1×25.2×28.1
550×850×1100 / 21.7×33.5×43.3
600×1000×1300 / 23.6×39.4×39.4
550×850×1100 / 21.7×33.5×43.3
600×1000×1300 / 23.6×39.4×39.4
Net weight (kg / Ibs)91.8 / 202.4
92.65 / 204.3
141.3 / 310.9
146.3 / 321.9
168 ±10 / 370 ±22
173±10 / 381 ±22
144.3 / 317.5
149.3 / 328.5
171 ±10 / 377 ±22
176 ±10 / 388 ±22
Electric requirement (230V, 60Hz) 6.5A 7.5A 9.5A 13.5A 9.5A 13.5A
Cat. No. AAH66011K AAH66021K AAH66031K AAH66041K - - AAH66131K AAH66141K - -
Electric requirement (230V, 50Hz) 6.0A 7.0A 7.5A 12.5A 7.5A 12.5A
Cat. No. AAH66012K AAH66022K AAH66032K AAH66042K - - AAH66132K AAH66142K - -
Electric requirement (380V, 50 / 60Hz) 5.5A 7.0A 5.5A 7.0A
Cat. No. - - - - AAH66058K AAH66068K - - AAH55158K AAH66168K
1)Technicaldata(accordingtoDIN12876)
*Abovespeificationvalueisrecordedby50Hz.2)OnlyHS-45H,55Hisrecordedby380V,60Hz.
*Theperformancevaluesreferto+20℃(68℉) ambienttemperature.*Productperformancemaybeaffectedbyambienttemperatures.
Low Temp. Recirculating Coolers - Intelligent Type
Recirculating Coolers (Chillers)
• HS-15, 20, 25, 35, 45, 55 models • HS-25H, 35H, 45H, 55H models
78
Barbed fittings Barbed fitting systems are geared for quick connecting of various size type tubes using pipe fittings, tube fittings, and hose fittings without tools.
Cat. No. DescriptionHXE1066 3/4”Maletobarbedfittingfortubing1”innerdiaHXE1067 3/4”Maletobarbedfittingfortubing3/4”innerdiaHXE1068 3/4”Maletobarbedfittingfortubing5/8”innerdiaHXE1069 3/4”Maletobarbedfittingfortubing1/2”innerdiaHXE1070 3/4”Maletobarbedfittingfortubing3/8”innerdia
AAA64501 1”BarbedfittingssetwithBallvalveAAA64502 3/4”BarbedfittingssetwithBallvalveAAA64503 5/8”BarbedfittingssetwithBallvalveAAA64504 1/2”BarbedfittingssetwithBallvalveAAA64505 3/8”BarbedfittingssetwithBallvalveAAA64506 1”BarbedfittingssetwithGatevalveAAA64507 3/4”BarbedfittingssetwithGatevalveAAA64508 5/8”BarbedfittingssetwithGatevalveAAA64509 1/2”BarbedfittingssetwithGatevalveAAA64510 3/8”BarbedfittingssetwithGatevalve
Connectors / AdaptersCat. No. DescriptionHXE1105 3/4”Maleto3/4”FemaleHXE1106 3/4”Maleto5/8”FemaleHXE1107 3/4”Maleto1/2”FemaleHXE1108 3/4”Maleto3/8”FemaleHXE1109 3/4” Male to 3/4” MaleHXE1110 3/4” Male to 5/8” MaleHXE1111 3/4” Male to 1/2” MaleHXE1112 3/4” Male to 3/8” Male
One touch adapters set Connect and exchange rigid tubing easily.
Cat. No. DescriptionHXE1075 12mmOnetouchadapter id9.0mm,od12.0mmHXE1076 10mmOnetouchadapter id6.5mm,od10.0mmHXE1077 8mmOnetouchadapter id5.5mm,od8.0mmHXE1078 6mmOnetouchadapter id4.0mm,od6.0mm
AAA64531 12mmAdapterssetwithBallvalveAAA64532 10mmAdapterssetwithBallvalveAAA64533 8mmAdapterssetwithBallvalveAAA64534 6mmAdapterssetwithBallvalve
Flexible fittings Stainless tubing designed for superior flexibility and with good chemical resistance.
Cat. No. DescriptionHXE1071 3/4”Maleto3/4”FlexiblefittingHXE1072 3/4”Maleto1/2”Femalewith1/2”Maleto1/2”Flexiblefitting
AAA64521 3/4”FlexiblefittingssetwithBallvalveAAA64522 1/2”FlexiblefittingssetwithBallvalveAAA64523 3/4”FlexiblefittingssetwithGatevalveAAA64524 1/2”FlexiblefittingssetwithGatevalve
Accessories & Options for Recirculating Coolers
Barbed fittings Connectors / Adapters Flexible fittings One touch adapters set
Recirculating Coolers
Recirculating Coolers
79
TubingCat. No. DescriptionHXE1079 1m12mmUrethanetubing id9.0mm,od12.0mmHXE1080 1m10mmUrethanetubing id6.5mm,od10.0mmHXE1081 1m8mmUrethanetubing id5.5mm,od8.0mmHXE1082 1m6mmUrethanetubing id4.0mm,od6.0mmHXE1083 1m1”PVCtubingwiththread id25.0mm,od31.0mmHXE1084 1m3/4”PVCtubingwiththread id19.0mm,od24.0mmHXE1085 1m5/8”PVCtubingwiththread id16.0mm,od20.5mmHXE1086 1m1/2”PVCtubingwiththread id12.0mm,od16.0mmHXE1087 1m3/8”PVCtubingwiththread id10.0mm,od14.0mmHXE1088 1m1”PVCtubingwithwire id25.0mm,od33.0mmHXE1089 1m3/4”PVCtubingwithwire id19.0mm,od26.0mmHXE1090 1m5/8”PVCtubingwithwire id15.0mm,od22.0mmHXE1091 1m1/2”PVCtubingwithwire id12.0mm,od18.0mmHXE1092 1m3/8”PVCtubingwithwire id9.0mm,od15.0mm
Tubing insulations EPDM insulation is used to reduce heat loss and condensation from cold water plumbing, chilled water, and refrigeration lines.
Cat. No. DescriptionHXE1093 EPDMInsulation,16mminnerdia.(9T)HXE1094 EPDMInsulation,19mminnerdia.(9T)HXE1095 EPDMInsulation,25mminnerdia.(9T)HXE1096 EPDMInsulation,28mminnerdia.(9T)HXE1097 EPDMInsulation,35mminnerdia.(9T)
Flexible tubingCat. No. DescriptionHXE1073 3/4”Flexibletubing(sus304,m)
HXE1074 1/2”Flexibletubing(sus304,m)
Tube clampsCat. No. DescriptionHXE1098 1”ClampHXE1099 3/4”Clamp
HXE1100 5/8”Clamp
HXE1101 1/2”ClampHXE1102 3/8”Clamp
Distributing fittings Distributing fittings connect even with small tubes with barb fittings.
Cat. No. DescriptionAAA64541 3-Waydistributingbarbedfittingsset(1/4”)AAA64542 3-Waydistributingbarbedfittingsset(3/8”)
Tubing Tubing insulations Tube clamps Distributing fittings
Recirculating Coolers
Accessories & Options for Recirculating CoolersRecirculating Coolers
Bath fluid Are bath fluids that may be suitable to use with the recirculating
cooler, in place of water.
Cat. No. DescriptionHXE1113 Distilledwater(20L)HXE1114 Ethyleneglycol(4L)HXE1115 Ethyleneglycol(20L)
External Sensor (only HS series) External temperature sensor (Pt 100) for measured value.
Cat. No. DescriptionCFA1943 3mcableforPt100sensor
Selection GuideLaboratory Refrigerators & Freezers
DescriptionOperating
Temp. Range(℃/℉)
ChamberVolume (L /cu ft)
Door type Shelve or Drawer Page
General Purpose LaboratoryRefrigerators
CLG-150
2 ~ 10 / 35.6 ~ 50
156 / 5.5
Glass or Solid
Shelve
82 - 84
CLG-300 319 / 11.3CLG-650 636 / 22.5CLG-850 843 / 29.7CLG-1400 1395 / 49.3
Pharmacy Refrigerators
CLP-650 636 / 22.5DrawerCLP-850 843 / 29.7
CLP-1400 1395 / 49.3
General Purpose LaboratoryFreezer
FLG-150-20 ~ -30 / -4 ~ -22
156 / 5.5Solid ShelveFLG-300 319 / 11.3
FLG-650 636 / 22.5
Accessories & OptionsDescription Page
for General Purpose Laboratory Refrigerators85for Pharmacy Refrigerators
for General Purpose Laboratory Freezers
General Purpose Laboratory Refrigerators.Pharmacy Refrigerators.General Purpose Laboratory Freezers.
Laboratory Refrigerators & Freezers
Safety functions1) Visual and audible alarms. - High / low temperature.
2) 2 individual over-current fuses for safety.
3) Door-open warning alarm : - During 2 minutes, visual alarm and after 2
minutes, intermittent audible alarm. - Fan automatically stops when the door is opened
to minimize heat loss and protect operator. - Equipped with a lock and key.
Optimum control performance1) Temperature selection either in ℃ or ℉.
2) CPU logic control system. - Economic power consumption control. - Optimum control of temperature.
3) User friendly controls with a splash proof / easy to clean keypad and with a clear VFD display.
4) Quick keypad lock button prevents accidental parameter changes.
5) Touch screen type monitor. - Colorful and bright VFD display with interactive
touch keys. - Visible set values: set point (SP) / present value (PV)
displayed together on the vibrant VFD display.
6) Optimizing defrost system. - Non-conventional defrost system, with an ad-
vanced defrost sensor (dual sensor) manages the defrost cycle by detecting trace amounts of frost build-up in the evaporator.
(Only for CLG / CLP / FLG-150, 300, 650 series) - The unique dual sensor defrost system is
initiated when needed, to maintain internal temperature uniformity during operation.
(Only for CLG / CLP-850, 1400 series)
Ideal construction1) High quality #304 grade stainless steel inner
chamber and dirt repellent powder coated external surface.
2) Perfectly magnetic sealed consistently maintains the temperature and the fully insulated chamber keeps the exterior shell of the equipment at a safe temperature.
3) Adjustable electro polished stainless steel shelving provides air flow around samples for uniformed tempering and allow for easy cleaning.
4) Heat treated glass door provides a clear obser-vation of samples.
Protect the global environment1) Use of HFC refrigerant prevents damage to the
ozone layer. - Complies with the Montreal Protocol on Sub-
stances That Deplete the Ozone Layer control measures.
Technical Benefits
General ApplicationsGeneral applications
Laboratory Refrigerators & FreezersCLG/CLP series FLG series
BOD Protocols •Chemical Storage •Chromatography Apparatus and Instrumentation •Clinical • •Culture •Enzymes •General Storage • •Life science •Medication • •Pharmaceutical •Pre-Freezing •Reagents •Test Samples • •Temperature Sensitive Materials •Vaccines • •
*For general purpose use and storage applications.
82
Laboratory Refrigerators & FreezersLaboratory Refrigerators & Freezers
General Purpose Laboratory Freezers
General Purpose Laboratory RefrigeratorsPharmacy Refrigerators
83
Laboratory Refrigerators & FreezersLaboratory Refrigerators & Freezers
Constructional features • Spacious and with different capacity sized refrigeration units to
choose from. - General purpose laboratory and pharmacy refrigeration units
come in volume capacities of 1395 liters. - General purpose laboratory freezer units come in volume cap-
acities of 636 liters.
• High quality #304 grade stainless steel interior.
• Fluorescent lighting included with general purpose laboratory and pharmacy refrigeration units.
- General Purpose Laboratory Refrigerators. (Excludes 150 Series)
- Pharmacy Refrigerators.
• Heat treated glass door for sample observation. (Only glass types) - Double-pane glass door with built in wire heaters in only G type
refrigeration units, to provide a clear observation of samples.
• Magnetic door seal. - Double cushioned packing provides impact absorption from
opening and closing of refrigeration or freezer unit door. - The magnet in the double cushioned packing ensures a perfect
seal around the chamber.
• Casters, comes standard with the laboratory refrigeration and freezer units and allows for easy transport and installation.
(Excludes 150 Series)
• Cable port for external probes or wires. (Only CLG / CLP models excludes 150 Series) - 50mm diameter cable port comes standard on the left side of
the unit. - Additional 50mm diameter cable ports can be custom ordered.
(optional)
• 150 series stand and stacking kit optional. (up to 2 chambers high) - For use in labs with limited space.
• Efficient system with durable parts. - Evaporating system for better thermal efficiency with corrosion-
resistant materials.
• Timer less Defrost system. - Advanced defrost sensor (dual sensor) manages the defrost cycle
by detecting trace amounts of frost build-up in the evaporator. (Only for CLG/CLP/FLG-150,300,650 series) - Unique dual system defroster only runs when needed therefore
internal temperature uniformity is maintained. (Only for CLG/CLP-850, 1400 series)
Operating features • CPU logic control system. - Optimum control of temperature with economical power
consumption.
• Enhanced digital controller, designed to simplify operation with a touch of a screen and with used of knob.
• Touch screen type display. - Colorful and bright VFD display with interactive touch keys. - Quick keypad lock button prevents accidental parameter
changes. - Visible set values : set point (SP) / present value (PV) displayed
together on the vibrant VFD display. - Setting and resolution indication : ∙ Temperature: 0.1℃ / ℉. ∙ Signal indication for operation status.
• Convenient and easy to maintain-warning alarm / monitoring system, and door lock system, etc.
• Recorder. (optional) - 6-point dot type recorder with a digital display. - Temperature recorder, 6 inches (152 mm) chart, 7-days drive. - Thermal Line type recorder.
Safety functions • Over current protection.
• Warning alarm with visual indicators and audible alarms. - Door open alarm. - High / low temperature alarm.
• Vice lock door closing mechanism.
With advanced safety features, the cold storage system providesa stable refrigerated environment for life science, pharmaceutical, biotechnology, clinical, and industrial laboratories.
84
Laboratory Refrigerators & FreezersLaboratory Refrigerators & Freezers
General Purpose Laboratory Refrigerators
Model CLG-150 CLG-300 CLG-650 CLG-850 CLG-1400Chamber volume (L / cu ft) 156 / 5.5 319 / 11.3 636 / 22.5 843 / 29.7 1395 / 49.3Display VFD and touch-screenTemperature range (℃ / ℉) 2 ~ 10 / 35.6 ~ 50Refrigerator (Hp) 1/8 1/6 1/3 1/6×2ea 1/4×2eaDoor type Heated glass or SolidLighting - 18W Fluorescent lamp 32W Fluorescent lamp
MeterialInterior Stainless steel #304Exterior Steel, 1.0 mm, powder coatingInsulation 60mm, Polyurethane foam
Dimensions(W×D×H)
Interior (mm / inch)550×580×490/ 21.7×22.8×19.3
550×580×1000/ 21.7×22.8×39.4
650×675×1450/ 25.6×26.6×57.1
750×775×1450/ 29.5×30.5×57.1
1425×675×1450/ 56.1×26.6×57.1
Exterior (mm / inch)683×791×870/ 26.9×31.1×34.4
670×719×1515/ 26.4×28.3×59.6
770×815×1965/ 30.3×32.1×77.4
870×915×1965/ 34.3×36×77.4
1545×815×1965/60.8×32.1×77.4
Net weight (kg / Ibs) 100 / 220.4 130 / 286.6 210 / 463.0 260 / 573.2 350 / 771.6Electrical Requirements (120V, 60Hz) 4.0 A 4.5 A 6.5 A 9.0 A 13.0 A
Cat. No.Solid door type AAHE1003U AAHE1013U AAHE1023U AAHE1033U AAHE1043UGlass door type AAHE1103U AAHE1113U AAHE1123U AAHE1133U AAHE1143U
Electrical Requirements (230V, 60Hz) 2.0 A 2.3 A 4.0 A 5.0 A 6.0 A
Cat. No.Solid door type AAAE1001 AAAE1011 AAAE1021 AAAE1031 AAHE1041Glass door type AAAE1101 AAAE1111 AAAE1121 AAHE1131 AAAE1141
Electrical Requirements (230V, 50Hz) 2.0 A 2.3 A 4.0 A 5.0 A 6.0 A
Cat. No. Solid door type AAHE1002 AAHE1012 AAHE1022 AAAE1032 AAHE1042Glass door type AAHE1102 AAHE1112 AAHE1122 AAHE1132 AAHE1142
Pharmacy Refrigerators
Model CLP-650 CLP-850 CLP-1400Chamber volume (L / cu ft) 636 / 22.5 843 / 29.7 1395 / 49.3Display VFD and touch-screenTemperature range (℃ / ℉) 2 ~ 10 / 35.6 ~ 50Refrigerator (Hp) 1 / 3 1 / 6×2ea 1 / 4×2eaDoor type Heated glass or Solid Lighting 32W Fluorescent lamp
MeterialInterior Stainless steel #304Exterior Steel, 1.0 mm, powder coatingInsulation 60mm, Polyurethane foam
Dimensions(W×D×H)
Interior (mm / inch) 650×675×1450 / 25.6×26.6×57.1 750×775×1450 / 29.5×30.5×57.1 1425×675×1450 / 56.1×26.6×57.1Exterior (mm / inch) 770×815×1965 / 30.3×32.1×77.4 870×915×1965 / 34.3×36×77.4 1545×815×1965 / 60.8×32.1×77.4Net weight (kg / Ibs) 210 / 463.0 260 / 573.2 350 / 771.6
Electrical Requirements (230V, 60Hz) 4.0 A 5.0 A 6.0 A
Cat. No.Solid door type AAHE3021 AAHE3031 AAHE3041Glass door type AAHE3121 AAHE3131 AAHE3141
Electrical Requirements (230V, 50Hz) 4.0 A 5.0 A 6.0 A
Cat. No. Solid door type AAHE3022 AAHE3032 AAHE3042Glass door type AAHE3122 AAHE3132 AAHE3142
※ Other size of chamber also available. (156L,300L)
General Purpose Laboratory Freezers
Model FLG-150 FLG-300 FLG-650Chamber volume (L / cu ft) 156 / 5.5 319 / 11.3 636 / 22.5Display VFD and touch-screenTemperature range (℃ / ℉) -20 ~ -30 / -4 ~ -22Refrigerator (Hp) 1 / 2 3 / 4 1Door type Solid
MeterialInterior Stainless steel #304Exterior Steel, 1.0 mm, powder coatingInsulation 60mm, Polyurethane foam
Dimensions(W×D×H)
Interior (mm / inch) 550×580×490 / 21.7×22.8×19.3 550×580×1000 / 21.7×22.8×39.4 650×675×1450 / 25.6×26.6×57.1Exterior (mm / inch) 683×791×885 / 26.9×31.1×34.8 670×719×1530 / 26.4×28.3×60.2 770×815×1980 / 30.3×32.1×78Net weight (kg / Ibs) 100 / 220.4 130 / 286.6 210 / 463.0
Electrical Requirements (230V, 60Hz) 3.5 A 4.0 A 4.3 ACat. No. Solid door type AAHE2001 AAHE2011 AAHE2021Electrical Requirements (230V, 50Hz) 3.5 A 4.0 A 4.3 ACat. No. Solid door type AAHE2002 AAHE2012 AAHE2022
※ Permissible ambient Condition: Temperature 18 to 35℃ (64.4 to 86℉), Maximum relative humidity 85%. ※ Technical data. (according to DIN 12880)
85
Accessories & Options
Dot type recorder Chart type recorder
Thermal line type recorder
for CLG / CLP / FLG Recorders
Electrical outlet (CLG)
Stand with casters (Only CLG-150/FLG-150)
Others
Wire Shelves Wire Shelves (Slide type)
Drawer (Slide type)
Shelves
Laboratory Refrigerators & Freezers
Include and Maximum Shelve Quantity
ProductsWire Shelves Wire Shelves (Slide type) Drawer (Slide type)
Include Maximum Include Maximum Include MaximumCLG-150 2 6 - 4 - 3CLG-300 3 11 - 7 - 5CLG-650 3 17 - 11 - 8CLG-850 3 17 - 11 - 8CLG-1400 6 34 - 22 - 16CLP-650 - 17 - 11 6 8CLP-850 - 17 - 11 6 8CLP-1400 - 34 - 22 12 16FLG-150 2 6 - 4 - 3FLG-300 3 11 - 7 - 5FLG-650 3 17 - 11 - 8
Sheleves, Drawers, Recoders, others
Cat. No. Description
Shelves
AAAE1511 Wire Shelves for CLG / FLG-150 / 300 (Flat type, Included Shelf Bracket)
AAAE1512 Wire Shelves for CLG / CLP / FLG-650, CLG / CLP-1400 (Flat type, Included Shelf Bracket)
AAAE1513 Wire Shelves for CLG / CLP-850 (Flat type, Included Shelf Bracket)
AAAE1514 Wire Shelves for CLG / FLG-150 / 300 (Slide type, Included Guide Rail)
AAAE1515 Wire Shelves for CLG / CLP / FLG-650, CLG / CLP-1400 (Slide type, Included Guide Rail)
AAAE1516 Wire Shelves for CLG / CLP-850 (Slide type, Included Guide Rail)
DrawersAAAE1517 Drawer Shelves for CLG / FLG-150/300 (Slide type, Included Guide Rail)
AAAE1518 Drawer Shelves for CLG / CLP / FLG-650, CLG / CLP-1400 (Slide type, Included Guide Rail)
AAAE1519 Drawer Shelves for CLG / CLP-850 (Slide type, Included Guide Rail)
Recorders
AAA8T500 Recorder (6 Point)
AAAE1501 Recorder (Chart type, 6”, 24hr / 7day)
AAAE1502 Chart Recorder Paper (6”, 60 Package)
AAAE1503 Recorder (Thermal Line chart recorder)
OthersAAAE1521 Cable Port for CLG / CLPseries (50mm) - without150 modelsAAAE1532 Electrical Outlet for CLG / CLP series with 230V Outlet (Korea style) - without150 models
Advanced Orbital ShakersMini ShakersRocking & Waving Shakers
Dual-Action ShakersEconomic Shakers
Shakers
Selection GuideShakers
Description Speed Range [RPM]
MaximumAmplitude Size
[mm / inch, dia]
Net Weight[kg/Ibs] Page
Benchtoptype- Open-Air
SKC-6075
Advanced Orbital Shaker 10 to 500
19 / 0.7465 / 143.3
90
SKC-6100 25 / 0.98SKC-6200 50 / 1.96SKC-7075 19 / 0.74
75 / 165.4SKC-7100 25 / 0.98SKC-7200 50 / 1.96SK-300
Dual-Action Shaker 10 to 300
40 / 1.624 / 52.9
92SK-600 29 / 63.9SK-71 70 / 2.4 50 / 110.2SKF-2025
Economic Shaker
10 to 500 7 / 0.3
20 / 44.1
93
SKF-2050 10 to 400 13 / 0.5SKF-2075 10 to 300 19 / 0.7SKF-2025R 10 to 450 7 / 0.3SKF-2050R 10 to 350 13 / 0.5SKF-2075R 10 to 250 19 / 0.7SKF-3050 10 to 400 13 / 0.5
33.68 / 74.25
SKF-3075 10 to 300 19 / 0.7SKF-3100 10 to 300 25 / 1.0SKF-3050R 10 to 350 13 / 0.5SKF-3075R 10 to 250 19 / 0.7SKF-3100R 10 to 250 25 / 1.0CMS-350 Mini Shaker 50 to 300 13 / 0.5 8 / 17.6 94CRS-350 Rocking Shaker
10 to 100[ Tilt 7~13° adjustable] 3.68 / 8.11
95CWS-350 Waving Shaker [ Tilt 0~13° adjustable] 3.75 / 8.27
Separatory Funnel Shakers
Description Speed Range [RPM]
VerticalStroke Length
[mm / inch]
Net Weight[kg/Ibs] Page
Benchtoptype RS-1 Separatory Funnel
Shakers 50 to 300 40 / 1.6 24.0 / 52.9 96
Accessories & OptionsDescription Page
for Shaker - Open-Air 97 - 101
Safety functions1) Self-protecting cut-off function :
- Over-current fuses for user safety.
2) User setting functions: Select automatic run or manual run after power has been interrupted.
3) Acceleration / deceleration circuit : (Excludes RS, CMS, CWS and CRS models)
- The shaker units stops and starts at the always same position.
- To prevent spillage from flasks and tubes the shaker gently starts up and gently stops.
4) If the load sensor detects any type of imbalance from the shaker it will reduce the shaking motion . (only SKC models)
Optimum control performance1) Easy to use, comes in a wide range of rpm setting
which covers most applications.
2) Professional electronic and program control. - Microprocessor PID controls. - Self-diagnostic function identifies any errors
and advises the user on how to correct the errors.
3) Multi-function shaking system: - Timer
SK SKF SKCWait on - • •Wait off • • •Program mode - - •
- Forward & Backward, Pause.
4) Similar key arrangements to the temperature humidity chamber, bath, circulator, and shaker.
- User-friendly controls, splash proof / easy to clean keypad and clear LED display.
(Only SK and SKF models) - Colorful and bright VFD display with interactive
touch keys. (SKC, CMS, CWS and CRS models)
5) End of shaking session unit stops while an audible alarm sounds. (Only RS models)
Ideal construction1) Dual shaking action- select from orbital or recip-
rocating shaking motion. (Only SK models)
2) Slim and low-profile design, reduces the vibration and sliding caused by the high speed shaking motion.
3) Brushless DC motor creates a smooth and quiet uniformed shaking motion.
4) Innovative triple-cam shaking system. (SKC models)
5) DD(Direct drive) motor allows the shaker to hold heavy loads, is quiet, high rpm, and durable.
(SKC models)
6) Dirt repellent powder coated external surface.
7) Wide range of accessories.
Technical Benefits
General ApplicationsGeneral applications
Open-Air and Separatory funnel ShakersSKC series SK. SKF series RS series CMS CRS / CWS
Bacterial suspensions • •Cell culture • • • •Diagnostic tests • • •Drug analysis • • • • •ELISA • • • •
Environmental technology (waste water and soil analysis) • • •
Enzyme immunoassays • • • •Extraction procedures • • • •General mixing • • • • •Hemolyzing blood sparation • • • •Hybridization • • • •Inorganic solvent extraction •Soil compound extraction •Solubility studies • • •
Solvent extraction for water quality analysis •
Staining and destaining • • • •Perparation for metal analysis •Pharmaceutical profiling • • • • •Protein synthesis • • • •
* For general purpose use applications.
88
ShakersShakers - Open - Air
Please visit .comFor further information on Jeio Tech´s Shaker productsInformation is readily available on our website.
89
Convenient and unique Shaking FunctionsThis unique shaker stops and starts at the always same position. This shaker is beneficial for semi-automated dosing or sampling of samples. Select between clockwise and counterclockwise shaking motion.
- These durable shaking systems are able to function stably at low rpm settings. (between 10-25rpm) Usually the SK models-10rpm (SKC models-30rpm) setting is great for low damage biological mixing tests and cell cultivation.
Shaking SystemShakers
only start / stop here
Power offPower off
Reciprocating motion
Orbital motion
Dual-action Shaking SystemAll SK, SI, and IS shaking units are dual-action. The user is able to select between orbital and reciprocating shaking motion. Simply change the type of shaking motion by changing the way the platform is connected.
Multi-function Shaking SystemIntensive multi-function shaking system surpasses all the previous levels of shaker units. Mix and match clockwise, counterclockwise, start, and stop motions. (Making 6 possible combinations - refer to each model spec.)
90
SKC-7075Optional Accessories •Universalplatforms,Dualuniversalplatforms,
see page 97-101 •Rubbermats,Universalattachments •Flaskclamps,Funnelclamps •Testtuberacks,Springwireracks,HalfSpringwireracks •Microplateholders •Labsticker
SKC Control Display
Advanced Orbital ShakersShakers
Please visit .comFor further information on Jeio Tech´s Shaker products Information is readily available on our website.
91
Advanced Orbital ShakersInnovative triple-cam shaking system with compact design and superior fabrications.Exclusive SKC shaker series can carry out low maintenance applications that demand heavy duty, continuous operation, and high reliability testing.
Shakers
Constructional features • Microprocessor PID controller provides feedback to motor to
maintain constant speed during operation. • Ideal DD(Direct Drive) Brushless Motor supports heavy loads, quiet
(beltless, brushless, and gearless), maintenance free, and delivers high torque at high speeds, smooth rotation.
• Slim and low-profile design (height of 122mm) useful for various app- lications for example usage in confined areas.
• Highly chemically resistant and durably manufactured. • Convenient universal platform exchange sliding. • Maintenance-free, triple cam system, able to handle heavy loads
with reduced vibration. • To prevent spillage from flasks and tubes the shaker gently starts
up and gently stops. • This unique shaker stops and starts at the always same position.
This shaker is beneficial for semi-automated dosing or sampling of samples.
• A wide range of accessories are available for attachment of any flask or vessel.
• If the load sensor detects any type of imbalance from the shaker it will reduce the shaking motion.
Operating features • Precise Orbital shaking action. • Powerful speed range :
30~500RPM-Vibration free.
Programmable shaking motion
Programming parametersMaximum Number of segments in one (1) pattern (Cycle) 20Maximum Number of Patterns (Cycle) saved 20
Shaking Motion-Forward & Backward, PauseTime 1min to 99hr 59minRPM 10 to 500
• Adopted bright VFD display, and capacitive touch sensor button. • Digital timer : 1min 99hr 59min, delayed ON / OFF.
Specifications & Ordering Informations
Model SKC-6075 SKC-6100 SKC-6200 SKC-7075 SKC-7100 SKC-7200Control system FeedbackcontrolPIDDisplay VFD
Shaking system
Motion type OrbitalSpeed range1) (RPM) 30 to 500Accuracy at 100 RPM ±1Amplitude size (mm / inch, dia) 19 / 0.74 25 / 0.98 50 / 1.96 19 / 0.74 25 / 0.98 50 / 1.96
Dimensions
Platform (W×D) (mm / inch)
Small 580×520 / 22.8×20.5 755×520 / 29.7×20.5Large 660×520 / 26.0×20.5 885×520 / 34.8×20.5
Overall (W×D×H) (mm / inch)582.8×618 ×122.2 754.8×662×122.2
22.9×24.3×4.8 29.7×26.1×4.8Net weight (kg / Ibs) 65 / 143.3 75 / 165.4
Electric requirements (230V, 50 / 60Hz) 0.4ACat. No. AAH30105 AAH30115 AAH30125 AAH30205 AAH30215 AAH30225Electric requirements (120V, 50 / 60Hz) 0.8ACat. No. AAH30106 AAH30116 AAH30126 AAH30206 AAH30216 AAH30226
1)Duetohigherspeedrangebetween350rpmand500rpm,werecommendthattheshakersneedextraattachmenttobefixedontheflooroftheworkingplace.
92 Operating features
• Select between orbital or reciprocating motion.
• Speed range: 10 to 300 rpm.
• Programmable shaking motion. - Run time: 10 sec to 999 hr 59 min 59 sec. - Forward & Backward, Pause: 10 sec to 59 min 50 sec.
• Maximum orbit size. - 40mm dia. (1.6″ dia.) for SK-300, 600. - 70mm dia. (2.8″ dia.) for SK-71.
• Digital LED display for speed and shaking motion.
Constructional features • Brushless DC motor creates a smooth and quiet uniformed shaking
motion. • To prevent spillage from flasks and tubes the shaker gently starts
up and gently stops. • This unique shaker stops and starts at the always same position.
This shaker is beneficial for semi-automated dosing or sampling of samples.
• Low-profile design useful makes it possible to stack multiple units on one rack.
• Highly chemically resistant and durably manufactured. • Wide range of accessories are available.
SK-300Optional Accessories •Universal/Dedicatedplatforms,Rubber
mats,Universalattachments. see page 97-101 •Flaskclamps,Funnelclamps
•Testtuberacks,Springwireracks •Microplateholders •Labsticker •Stagerack(max.4stages)
Dual-Action ShakersBenchtop platform shakers with advanced dual-shaking features, for flask up to maximum 6L.Performances orbital or reciprocating action and variable-speed control provided gentle to vigorous agitation. Offers user-friendly operating and safety features for reliable shaking of lab glassware.
Shakers
Specifications & Ordering Informations
Model SK-300 SK-600 SK-71
Shaking system
Motion type OrbitalorReciprocatingmotionselectableSpeed range (RPM) 10 to 300
Timer Runtime:10secto999hr59min59secForward&Backward,Pause:10secto59min50sec
Amplitude size (mm / inch, dia.) 20,30,40/0.8,1.2,1.6Available-Standard30/1.2 30,40,50,60,70/1.2,1.6,2.0,2.4,2.8 Available - Standard 30 / 1.2
Recip stroke length (mm / inch) 20,30,40/0.8,1.2,1.6Available-Standard30/1.2 30,40,50,60,70/1.2,1.6,2.0,2.4,2.8 Available - Standard 30 / 1.2
Dimensions
Platform (W×D) (mm / inch) 350×350 / 13.8×13.8 450×450 / 17.7×17.7 755×481 / 29.7×18.9
Overall (W×D×H) (mm/inch)410×490×150 / 16.1×19.3×5.9
510×595×150 / 20.1×23.4×5.9
820×610×166 / 32.3×24.0×6.5
Net weight (Kg / lbs) 24.0 / 52.9 29.0 / 63.9 50.0 / 110.2Electrical Requirements (230V, 50 / 60Hz) 0.2A 0.2A 0.2ACat. No. AAH31105K AAH31205K AAH31305KElectrical Requirements (120V, 50 / 60Hz) 0.4A 0.4A 0.4ACat. No. AAH31106U AAH31206U AAH31306U
93
Economic ShakersThe Distinctive and economical SKF models offer the most felicitous shaking motionTwo types of shaking motions (orbital or reciprocating), four types of an orbit or reciprocating lengths. The compact and interchangeable platform design accommodates various types and sizes of vessels and suitable for use in chambers.
Shakers
Operating features • 12 options with different amplitude sizes and shaking motion
(orbital or reciprocating) are available.
• Speed range: selective Max. RPM for each models. - 10 to 500, 450, 400 300, 350, 250 rpm.
• Programmable shaking motion. - Delay On / Off Time: 10 sec to 999 hr 59 min 59 sec. - Forward & Backward, Pause: 10 sec to 59 min 59 sec.
• Max. orbit or reciprocating size. (Factory fixed) - 7, 13, 19 mm dia, [0.3″, 0.5″, 0.75″ dia.] for SKF-2000 series. - 13, 19, 25 mm dia, [0.5″, 0.75″, 1.0 dia.] for SKF-3000 series.
• Digital LED display for speed and shaking motion.
• A large selection of attachments is provided for the use of various vessels and sizes.
- Interchangeable top platforms for flasks, dishes or microplates available separately. (Dual Stacking Tray)
Specifications & Ordering Informations
Model SKF-2025 SKF-2050 SKF-2075 SKF-2025R SKF-2050R SKF-2075R
Shaking system
Motion type Orbital Orbital Orbital Reciprocating Reciprocating ReciprocatingSpeed range (RPM) 10 to 500 10 to 400 10 to 300 10 to 450 10 to 350 10 to 250Accuracy at 100 RPM ± 2
Timer DelayOn/OffTime:1minto999hr59min Forward&Backward,Pause:10secto99hr59min
Amplitude size (mm / inch) 7 / 0.3 13 / 0.5 19 / 0.7 7 / 0.3 13 / 0.5 19 / 0.7
DimensionsPlatform (W×D) (mm / inch) 320×260 / 12.6×10.2Exterior (W×D×H) (mm / Inch) 355×375×140 / 14.0×14.8×5.5Net weight (kg / Ibs) 20 / 44.1
Electrical Requirements (230V, 50/60Hz) 0.2 A 0.2 A 0.2 A 0.2 A 0.2 A 0.2 ACat. No. AAH3A105 AAH3A115 AAH3A125 AAH3A205 AAH3A215 AAH3A225Electrical Requirements (120V, 50/60Hz) 0.4 A 0.4 A 0.4 A 0.4 A 0.4 A 0.4 ACat. No. AAH3A106 AAH3A116 AAH3A126 AAH3A206 AAH3A216 AAH3A226
Model SKF-3050 SKF-3075 SKF-3100 SKF-3050R SKF-3075R SKF-3100R
Shaking system
Motion type Orbital Orbital Orbital Reciprocating Reciprocating ReciprocatingSpeed range (RPM) 10 to 400 10 to 300 10 to 300 10 to 350 10 to 250 10 to 250Accuracy at 100 RPM ± 2
Timer DelayOn/OffTime:1minto999hr59min Forward&Backward,Pause:10secto99hr59min
Amplitude size (mm / inch) 13 / 0.5 19 / 0.7 25 / 1.0 13 / 0.5 19 / 0.7 25 / 1.0
DimensionsPlatform (WxD) (mm / inch) 350×350 / 13.8×13.8Exterior (WxDxH) (mm / Inch) 410×490×140 / 16.1×19.3×5.5Net weight (kg / Ibs) 30 / 74.25
Electrical Requirements (230V, 50/60Hz) 0.2 A 0.2 A 0.2 A 0.2 A 0.2 A 0.2 ACat. No. AAH3A305K AAH3A315K AAH3A325K AAH3A405K AAH3A415K AAH3A425KElectrical Requirements (120V, 50/60Hz) 0.4 A 0.4 A 0.4 A 0.4 A 0.4 A 0.4 ACat. No. AAH3A306U AAH3A316U AAH3A326U AAH3A406U AAH3A416U AAH3A426U
94 Operating features
• Microprocessor PID controller provides feedback to the motor to maintain constant rpm.
• Suitable at even low speeds for low rpm sensitive experimental tests.
- Speed range : 50 to 300 rpm • One-touch timer facilitative for time-dependent studies. - 1 min to 99 hour 59 min • Orbit size: 13mm dia. [0.51″ dia.]
• Digital LED display for speed and shaking motion.
Constructional features • Brushless DC motor creates a smooth, quiet, and uniformed
shaking motion. • The VFD controller display is quick and easy to view set up speed
and operational speed. • Designed for Portability, constructed with a lightweight plastic
body for facilitative use in experimental chamber. (incubator and etc)
• Removable rubber mat can be used to transport well-pates (Max. 6 ea) and dishes-optional.
• Brushless DC motor creates a smooth, quiet, and uniformed shaking motion.
• Highly chemically resistant and durably manufactured. • Wide range of accessories are available.
CMS-350Optional Accessories •UniversalRubbermats,Universal
attachments. see page 97-101 •Flaskclamps,Funnelclamps
•Testtuberacks,Springwireracks •Microplateholders •Labsticker
Mini ShakersCompact and lightweight design for easy mobility and for use in areas with limited space.The real-time RPM controlling is responsive with the speed control knobIdeal for hybridization, immunocytochemistry, gel staining/destaining, and other bioscience applications.
Shakers
Specifications & Ordering Informations
Model CMS-350Control system FeedbackcontrolPIDDesplay VFD
Shaking system
Motion type OrbitalSpeed range (RPM) 50 to 300Accuracy at 100 RPM ±5Timer 1min. to 99hrs. 59min.Orbit size (mm / inch, dia) 13 / 0.51Max. load (kg / Ibs) up to 4 / 8.81
MaterialRubber mat (standard) PP+RubberBody PP
Dimensions
Rubber mat (W×D) (mm /inch) 276×276 / 10.87×10.87Platform (W×D) (mm /inch) 250×250 / 9.8×9.8Overall (W×D×H) (mm /inch) 276×334×130 / 10.9×13.1×5.1Net weight (Kg / lbs) 8 / 17.6
Permissible relative temperature (℃ / ℉) 5~40 / 41~104Electrical Requirements AV100~240V,50/60Hz
Cat. No. KR Plug AAH3B1115KUS Plug AAH3B1115U
95
Adjustable tilt angle and variable digital speed controller provides any possible movement for outstanding rocking or waving results. Removable tray and digital timer can be applied to variety purposes- Ideal for ELISA, enzyme immunoassays, protein synthesis, hybridization staining or
destaining gels, pharmaceutical profiling, and among other laboratory applications.
Operating features • Suitable at even low speed (10rpm) for sensitive experimental tests.
• Digital speed control provides a gentle to vigorous motion. - Rocking shaker: 5 to 100 rpm. - Waving shaker: 8 to 100 rpm.
• User friendly, tilt angle setting can be adjusted to fit user’s exper-imental needs.
- Rocking shaker: Tilt 7 ~ 13° adjustable. - Waving shaker: Tilt 0~ 13° adjustable.
• One-touch timer facilitative for time-dependent studies. - 1 min to 99 hour 59 min.
Constructional features • Brushless DC motor creates a smooth and quiet uniformed
shaking motion.
• The controller display adopts VFD. It is easy to indicate speed set up and operating condition.
• Designed for Portability, constructed with lightweight materials for convenient use in an experiment chamber.
• 3 type of removable trays surface can be used to transport tubes, well-pate and etc.
(Included Dimpled mat, and optional Rubber mat, Universal harness)
CRS-350 / CWS-350Included Accessories •DimpledMatOptional Accessories •RubberMat
see page 97-101 •UniversalHarness
Specifi cations & Ordering Informations
MODEL CRS-350 CWS-350Control system FeedbackcontrolwithPIDDesplay VFD
Shaking system
Motion type Rockingtype Waving TypeSpeed range (RPM) 5 ~ 100 8 ~ 100Accuracy at 100 RPM ±5Tilt angle 7 ~ 13° 0 ~ 13°Max. load (kg / Ibs) 5 / 11.02
MaterialDimpled mat (standard) PP (Polypropylene)+SiliconeBody PP (Polypropylene)
Permissible ambient temperature (℃/℉) 5~60 / 41~140
DimensionTray (W×D) (mm / inch] 276×276×10.87×10.87Overall (W×D×H) (mm / inch) 276×320×150 / 10.87×12.6×5.91Net weight (kg / Ibs) 3.7 / 8.16
Electrical Requirements AV100~240V,50/60Hz
Cat. No.KR Plug AAH391115K AAH381115KUS Plug AAH391115U AAH381115U
Rocking & Waving ShakersShakers
96 Operating features
• Vertical reciprocating action.
• Speed range: 50 to 300 rpm.
• Time range: 0~60min / continuos operation.
• Maximum shaking width: 40mm. (1.6″)
• Digital LED speed indicator.
Constructional features • Easy to use, comes in a wide range of rpm setting which covers
most applications.
• Precision of speed control, feedback loop to a digital controller.
• Standard timer range 0-60 minutes, can be overridden upon request.
• End of shaking session unit stops while an audible alarm sounds.
• Easily adjustable holder/maximum of 5 holders per each side. (10 total)
* Funnel capacities (per each side)
Capacity Round type funnel Slim type funnelunder 500ml 3-5 5500ml 3 31L - 3
RS-1 Included Accessories •Funnelholder6sets
(Orderinginformation-Cat.No.:AAA32501)
Separatory Funnel ShakersIntensive vertical reciprocating quick solvent extraction shaking unit.
The separatory funnel shaker is able to shake six samples in identical conditions for any series or comparative protocols in chemistry, biotech, and medical labs.
Shakers
Specifications & Ordering Informations
Model RS-1
Shaking system
Motion type Vertical reciprocatingSpeed range (RPM) 50 to 300Timer 60 min or continuous operationVertical stroke length (mm / inch) 40 / 1.6
DimensionsOverall (W×D×H) (mm / inch) 445×730×505 / 17.5×28.7×19.9Max. load per each side (kg / lbs) 3.0 / 6.6Net weight (Kg / lbs) 24.0 / 52.9
Electrical Requirements (230V) 50Hz,0.4A 60Hz,0.4ACat. No. AAH32012K AAH32015K
97
Accessories & Options for ShakersShakers
Universal platforms & Flask clamps, Funnel clamps The universal platforms provide flexibility for mixing different sized assortment of test tubes and glassware on a single platform. Available in
different size assortment of clamps for Erlenmeyer flasks and Separatory funnels.
Description SK-300 SK-600 SK-71 CMS-350 SKF-2000 [R] SKF-3000 [R]Universal platform Cat. No. AAA31501-V1 AAA31502-V1 AAA31503-V1 AAA3B501 AAA3A501 AAA31501-V1
Max. mountable funnel clamps *Cat. No.
Erlenmeyer flask sizeSteel Plastic
AAA23550 AAA30570 for 50mL 36 55 99 16 21 36AAA23551 AAA30571 for 100mL 28 44 74 9 14 28AAA23552 AAA30573 for 250ml 13 24 39 9 8 13AAA23556 AAA30574 for 300mL 13 24 39 9 8 13AAA23553 AAA30575 for 500ml 10 16 25 5 5 10AAA23554 AAA30576 for 1L 5 8 14 4 3 5AAA23555 AAA30577 for 2L 4 5 9 1 - 4AAA23557 - for 2.8L 2 4 6 - - 2AAA23558 - for 4L 1 2 4 - - - AAA23559 - for 6L 1 2 4 - - -
Max. mountable funnel clamps *Cat. No. Separating funnel size
AAA23562 for 250mL 4 6 11 3 4 4AAA23563 for 500ml 3 4 9 2 3 3AAA23564 for 1L 2 3 5 2 2 2AAA23565 for 2L 1 2 4 - - 1
Description SKC-6000 Series SKC-7000 SeriesUniversal platform Cat. No. AAA30501 AAA30503 AAA30502 AAA30504
Dual universal platform Cat. No. - - AAA30541 1) AAA30542 1)
Universal platform size (mm / inch) 580×520 / 22.8×20.5 660×520 / 26.0×20.5 755×520 / 29.7×20.5 885×520 / 34.8×20.5Cat. No.
Erlenmeyer flask sizeSteel Plastic
AAA23550 AAA30570 for 50mL 84 96 108 (under 108) 126 (under 126)AAA23551 AAA30571 for 100mL 54 66 72 (under 72) 84 (under 84)AAA23552 AAA30573 for 250ml 33 39 42 (under 42) 51(under 51)AAA23556 AAA30574 for 300mL 28 32 36 40AAA23553 AAA30575 for 500ml 20 24 27 30AAA23554 AAA30576 for 1L 14 16 18 20AAA23555 AAA30577 for 2L 8 11 12 13AAA23557 - for 2.8L 6 7 9 11AAA23558 - for 4L 4 6 8 9AAA23559 - for 6L 3 4 6 7
Max. mountable funnel clamps *Cat. No. Separating funnel size
AAA23562 for 250mL 14 16 18 20AAA23563 for 500ml 9 10 11 14AAA23564 for 1L 7 8 9 12AAA23565 for 2L 5 6 7 8
* Flask clamps and funnel clamps for universal platform are sold separately.1)Universalplatformattachmentsaremountedonthedualuniversalplatform,Underthedualuniversalplatformaremountedonly50ml,100ml200ml-Refertotheabovechart.(Distancebetween
platforms is 175mm)
Universal Platforms Flask Clamps Funnel Clamps
98
Accessories & Options for ShakersShakers
Spring wire racks Ideal for holding a wide variety of tubes, flasks, and other glassware. All component are made of stainless steel.
Description SK-300 SK-600 SK-71 CMS-350 SKF-2000 [R] SKF-3000 [R]Spring wire racks Cat. No. AAA31521 AAA31522 AAA31523 AAA3B511 AAA3A521 AAA31521-V1
Max. inserting flask clampsErlenmeyer flask size
for 50mL 16 25 40 12 12 16for 100mL 9 16 28 6 6 9for 250ml 4 9 15 3 3 4for 300mL 4 9 15 3 3 4for 500ml 4 5 10 3 3 4
for 1L 2 4 8 2 2 2for 2L 1 2 4 - - 1
for 2.8L 1 2 4 - - 1
Description SKC-6000 Series SKC-7000 SeriesSpring wire racks Cat. No. AAA30521 AAA30522 AAA30523 AAA30524
Max. inserting flask clampsErlenmeyer flask size
for 50mL 30 35 45 50for 100mL 20 24 28 32for 250ml 12 15 18 21for 300mL 12 15 18 21for 500ml 9 12 15 18
for 1L 6 8 10 12for 2L 4 5 6 7
for 2.8L 3 3 4 5
Universal Platforms (for SKC)
Spring wire racks (for SKC)
Dual Universal Platforms (for SKC)
Spring wire rack (for SKF)
99
Accessories & Options for ShakersShakers
Universal attachments (for SKC)
Test Tube Racks
Dimpled mats (for CRS / CWS)
Universal attachments (Utility carriers) Several adjustable clamping bars to quickly secure a variety of glassware or tubes on non-skid rubber mat. Suitable for different sizes of flat
bottomed flasks.
Models SK-300 SK-600 SK-71 CMS-350 SKF-2000 [R] SKF-3000 [R] SKC-6000 Series SKC-7000 SeriesCat. No. AAA31511 AAA31512 AAA31513 AAA3B521 AAA3A511 AAA31511 AAA30511 AAA30512 AAA30513 AAA30514
Test tube racks Highly durable stainless steel racks with adjustable angle and tube height support. Simply release and mount racks. Requires an universal
platform which are sold separately.
Cat. No. Description Mountable capacity of racks*AAA23581 for 86 test tubes 8mm dia. (0.3”)
AAA23582 for 86 test tubes 10mm dia. (0.4”)
AAA23583 for 58 test tubes 12mm dia. (0.5”)
AAA23584 for 58 test tubes 14mm dia. (0.6”)
AAA23585 for 32 test tubes 16mm dia. (0.7”)
AAA23586 for 19 test tubes 25mm dia. (1.0”)
AAA23594 for 10 test tubes 35mm dia. (1.4”)
* No declination※Wecanmanufactureothersizeoftesttuberackstomeetyourspecificrequirements.Contactusfordetails.
Dimpled Mat
Models SKF-2000 [R]Cat. No. AAA3A532
SK-300 SK-600 SK-71 CMS-350 SKF-2000[R],3000[R]Series SKC-6000 Series SKC-7000 Series2EA 4EA 6EA 2EA 2EA 8EA 9EA 9EA 12EA
100
Accessories & Options for ShakersShakers
Dedicated platforms If using a single flask size only, the dedicated platforms provide maximum capacity, and come with clamps installed. Provided standard clamp
size are 250mL and 500mL, but possibly provide the other size of clamps also.
Cat. No. DescriptionAAA31551 AnuniversalplatformforSK-300,SKF-3000serieswith250mLflaskclamps13ea
AAA31552 AnuniversalplatformforSK-300,SKF-3000serieswith500mLflaskclamps10ea
AAA31561 AnuniversalplatformforSK-600with250mLflaskclamps24ea
AAA31562 AnuniversalplatformforSK-600with500mLflaskclamps16eaAAA23631 AnuniversalplatformforSK-71with250mLflaskclamps39eaAAA23632 AnuniversalplatformforSK-71with500mLflaskclamps25eaAAA23611 AnuniversalplatformforSI-300serieswith250mLflaskclamps13eaAAA23612 AnuniversalplatformforSI-300serieswith500mLflaskclamps9eaAAA23621 AnuniversalplatformforSI-600serieswith250mLflaskclamps18eaAAA23622 AnuniversalplatformforSI-600serieswith500mLflaskclamps13eaAAA23631 AnuniversalplatformforIS-971serieswith250mLflaskclamps39eaAAA23632 AnuniversalplatformforIS-971serieswith500mLflaskclamps25ea
*Adedicatedplatformissoldwithsettingeachmax.mountableamountofflaskclampson.
Rubber mats The non-skid rubber mats are designed for low-speed applications, allow for quick addition or removal of flasks, plates or tubes.
Models SK-300 SK-600 SK-71 CMS-350 SKF-2000 [R] SKF-3000 [R] SKC-6000 Series SKC-7000 SeriesCat. No. AAA31531 AAA31532 AAA23533 AAA38501 AAA3A531 AAA31531 AAA30531 AAA30532 AAA30533 AAA30534
Plastic Clamps Dedicated Platform
Rubber mats (for SKC)
101
Accessories & Options for ShakersShakers
Microplate holders Available in three styles. A Tower type holder, two Flat types (small and large) and a Single type. The large flat holders will hold 4 standard or deep
well plates. The small flat holders will hold 3 standard or deep well plates. The single holders will hold only 1 standard or deep well plate.
Microplate holders Tower type Flat-A type (large) Flat-B type (small) Single typeCat. No. AAA23651 AAA23652 AAA23653 AAA23654
Max. mountable holdersSK-300 6 - 2 8SK-600 10 2 3 15SK-71 16 3 5 25
CMS-350 6 - - 6SKF-2000 (R) 4 - 1 6SKF-3000 (R) 6 - 2 8
SKC-6000 SeriesAAA30501 16 3 4 20AAA30503 19 4 5 23
SKC-7000 SeriesAAA30502 22 5 6 25AAA30504 25 6 7 28
*Microplateholdersneedtobemountedonanuniversalplatformwhichissoldseparately.
Dual stacking tray for Microplate
Models CMS-350 SKF-2000 [R]Cat. No. AAA3B531 AAA3A541
Dual stacking tray size 319×285×96 / 12.6×11.2×3.8
319×285×96(105) / 12.6×11.2×3.8
Max. mountable Microplate
Total 12EA(each try for 6EA)
Total 12EA(each try -6EA)
Lab Sticker Alternative to flask clamps for securing vessels to a shaker platform the ideal way to secure containers such as bottles and dishes on the universal
platform is that cannot be held with conventional flask clamps. The lab sticker can be re-generated to a new condition by washing it with mild detergent and water. It cannot be used in water baths. For safe operation, suggest increasing the RPM gradually.
Description Lab StickerLab Sticker Cat. No. AAA30551Size (mm / inch, W×D×H) 200×200×5 / 7.9×7.9×0.2
*LabStickerneedtobemountedonanuniversalplatformwhichissoldseparately.
Large tray for Microplate
Models CMS-350 SKF-2000 [R]Cat. No. AAA3B532 AAA3A542
Tray size 396×273×21 / 15.6×10.7×0.8
396×273×21 / 15.6×10.7×0.8
Max. mountable Microplate Total 9EA Total 9EA
Dual stacking tray for microplate Microplate Holders Lab Sticker
Magnetic Stirrers - Scale & Digital Type.Magnetic Stirrers - Multi Position Type.Overhead Stirrers - Economic, Analog & DigitalVortex Mixer.
Stirrers & Vortex Mixer
Selection GuideMagnetic Stirrers
Description Speed Range[RPM]
Stirring Capacity, Max. [L, H2O]
Positions Page
Scale TypeMS-12B
150 ~ 2,5002 -
104
MS-17B 4 -MS-22B 5 -
Digital TypeMS-17G
30 ~ 2,000
4 -MS-22G 5 -
Multi-Position
MS-23M 1.5* 6MS-32M 1.5* 6MS-33M 2.25* 9MS-51M 1.25* 5MS-52M 2.5* 10MS-53M 3.75* 15
* Erlenmeyer flask : Usable under 250㎖ in case full positions.
Overhead StirrersDescription Speed Range
[RPM]Stirring Capacity,
Max. [L, H2O]Page
Economic TypeMSE-1 UP to 1,400 20
106
MSE-2 UP to 1,200 30MSE-3 UP to 900 50
Analog TypeMSM-1 50 ~ 1,400 20MSM-2 50 ~ 1,200 30MSM-3 50 ~ 900 50
Digital TypeMSP-1 50 ~ 1,400 20
107MSP-2 50 ~ 1,200 30MSP-3 50 ~ 900 50
Vortex MixerDescription Speed Range
[RPM]Orbit Size[mm/inch, Ø] Operating Mode Page
Basic type 0 ~ 3,000 4 / 0.16 Touch, Continous, High-Continous
108Economic type 0 ~ 3,000 4 / 0.16 Touch, Continous
Accessories & OptionsDescription Page
for Magnetic Stirrer 109for Overhead Stirrer 110for Vortex Mixer 109
General ApplicationsStirrersFacilitating Crystallization, Evaporating Solvents, Chemical Reactions, Titration, Distillation Procedures, Suspensions, Dissolving Media, Food products.
Overhead stirrerBeverage production, Dairy products, Food, Sugar & Candy production, Chemistry / Petrochemistry, Ceramics, Water treatment, Cosmetic, Colorant/Paint production and Paper manufacture etc.
Vortex mixer Enzymatic and RIA assays · General test tube mixing, Biochemical assays, Vortexing cell suspensions, Mixing tissue samples, Viral dilutions preparations, Precipitated Assays.
Magnetic Stirrers (MS-B/G/M types)
- Easy to use, broad rpm speed range covers most applications.
- Microprocessor PID controls. (only MS-G/M types)
- Speed can be controlled regardless of the weight of the experimental sample.
- Magnetic stirrer rapidly works in real-time according to the RPM and safety. (MS-B type)
- Controls are even safer when the magnetic stirrer is used in low speed rotation.
- Powerful magnets and motor guarantee a high-speed and a proper management of the device.
- BLDC is less noisy and more durable than regular DC motors.
Overhead Stirrers (MSE/MSM/MSP types)
- Broad range of rpm speeds, high viscosity, and powerful torque covers various applications.
- PID feedback control system controls and main-tains constant motor speed under conditions of changing viscosity. (MSM / MSP types)
- Bright and recognizable FND display. (MSM / MSP types)
- Compact and slim head design takes up minimal space therefore comfortable to use.
- Aluminum main body sturdy and efficiently absorbs the heat generated by the motor.
Vortex Mixer (VM-96B/96E)
- In less than 4 second a vortex is made with amplitude of rotation.
: 4mm and rate of rotation : 0 ~ 3,000rpm (B type) 200~3000rpm (E type)
- Offered easy converter mode between touch and continuous.
- High sensitive touch switch mode used to reduce wrist stress when the user is pushing and holding their test samples.
- Functional BLDC motor offers accurate control of speed.
- Low center of gravity design minimizes vibration and sliding movement caused by high rpm speed.
Technical Benefits
104
Magnetic Stirrers - Scale & Digital & Multi-position TypeStrirrers & Vortex Mixer
Constructional Features • Ergonomic design, lightweight, simple to use and efficient low
profile structure.
• 120mm (MS-12B), 170mm, and 220mm / included top plate provided.
• The white & black silicone plate cover (Only MS-B, G types) and the non-slip strength of the rubber feet prevent the sample from sliding.
• BLDC is less noisy and more durable than regular DC motors.
• Best-in-the-class with broad range of RPM speed is reliable.
• Built in thermal shutdown and current limit protection.
Additional MS-G Type Features • Microprocessor PID controls.
• Convenient program and timer modes.
• Bright and vivid VFD display and responsive touch screen buttons.
• Gradual start-up prevents users from splashing of samples.
• Included M12 rod holder for clamping in samples.
Multi-position Type Features • User friendly and timer mode allows the user to select from one
point in one row, or one point in one column, one row, one column, or multiple rows or columns, with different rpm and timer settings.
• Easy to read digital VFD control display and beautifully illuminate LED single position, multiple position, row position, & column position lighting.
• Non-slip see through silicon place mat. (optional)
• Uncompromising safety devices.
• Supported various number of multi position stirring to meet user demands.
• #304 grade stainless steel and chemical resistant top-plate.
105
Magnetic Stirrers - Scale & Digital & Multi-position TypeStrirrers & Vortex Mixer
Specifications & Ordering Informations
Model MS-12B MS-17B MS-22B
Technical data
Speed control Electronic speed controlStirring Capacity (Liter, H2O) 2 4 5Speed range (RPM) 150 ~ 2,500Speed display NoneMotor rating input / output (W) 2.9 / 1.6Magnetic bar (Ø×L, mm / Inch), Max. 8×30 / 0.31×1.18 8×40 / 0.31×1.57 10×50 / 0.39×1.97Load, Max (kg / lbs) 15 / 33.07 20 / 44.09 25 / 55.12
Top plateMaterial Poly propylene with non-slip silicon coverDimension (mm / inch, Ø) 120 / 4.72 170 / 6.69 220 / 8.66
General data
Body material Poly propylene
Dimension (mm / inch, W×D×H)130×130×65 / 5.12×5.12×2.56
185 ×185×65 / 7.28×7.28×2.56
230×230×65 / 9.06×9.06×2.56
Weight (kg / lbs) 0.6 / 1.32 0.9 / 1.98 1.1 / 2.43Electrical requirements AC 100 ~ 240V, 50 / 60Hz (only MS-12B, 17B with power adapter)
Power consumption (W) 5 6Protection class (DIN EN 60529) IP42
Cat. No.Persian blue
KR plug AAH330115BK AAH330215BK AAH330315BKUS plug AAH330115BU AAH330215BU AAH330315BU
YellowKR plug AAH330115YK AAH330215YK AAH330315YKUS plug AAH330115YU AAH330215YU AAH330315YU
Specifications & Ordering Informations
Model MS-17G MS-22G
Technical data
Speed control Feedback control with PIDStirring Capacity (Liter, H2O) 4 5Speed range (RPM) 30 ~ 2,000Speed display VFDMotor rating input / output (W) 2.9 / 1.6Magnetic bar (Ø×L, mm / Inch), Max. 8×40 / 0.31×1.57 10×50 / 0.39×1.97Load, Max (kg / lbs) 20 / 44.09 25 / 55.12
Top plateMaterial Poly propylene with non-slip silicon coverDimension (mm / inch, Ø) 170 / 6.69 220 / 8.66
General data
Body material Poly propylene
Dimension (mm / inch, W×D×H)210×280×72 / 8.27×11.02×2.82
260×360×72 / 10.24×14.17×2.82
Weight (kg / lbs) 1.35 / 2.98 1.75 / 3.86Electrical requirements AC 100 ~ 240V, 50 / 60Hz Power consumption (W) 6Protection class (DIN EN 60529) IP42
Cat. No.Persian blue
KR plug AAH331215BK AAH331515BKUS plug AAH331215BU AAH331515BU
YellowKR plug AAH331215YK AAH331515YKUS plug AAH331215YU AAH331515YU
Specifications & Ordering Informations
Model MS-23M MS-32M MS-33M MS-51M MS-52M MS-53M
Technical data
Speed control Feedback control with PID
StirringPositions 6 6 6 5 10 15Speed range (RPM) 30 ~ 2,000
Stirring point distance (mm / inch, W×D)
118×170 / 4.64×6.69
115×90 / 4.52×3.54
117×90 / 4.6×3.54 90 / 3.54 117×90 / 4.6×3.54
Timer 1 min. to 99 hours 59 min.Speed display VFDMotor rating input / output (W) 2.9 / 1.6Load, Max (kg / lbs) 30 / 66.14
General data
Dimension(mm / inch, W×D×H)
377×434×81 / 14.84×17.09×3.19
254×434×81 / 10×17.09×3.19
377×434×81 / 14.84×17.09×3.19
130×591×75 / 5.12×23.27×2.95
251×591×75 /9.88×23.27×2.95
378×591×75 /14.89×23.27×2.95
Weight (kg / lbs) 6 / 13.23 5 / 11.02 7 / 15.43 4 / 8.82 8 / 17.64 11 / 24.25Electrical requirements AC 100 ~ 240V, 50 / 60HzPower consumption (W) 45 45 54 45 85 135Protection class (DIN EN 60529) IP 21
Cat. No.KR plug AAH332115K AAH332215K AAH332315K AAH332415K AAH332515K AAH332615KUS plug AAH332115U AAH332215U AAH332315U AAH332415U AAH332515U AAH332615U
106 Constructional Features
• Compact and slim head design. • Powerful torque easy use with high viscosity samples. • Overload and thermal protection for safe operation. - MSM model: sequenced-visible and audible alarms and stop
systems. • Speed adjustment dial knob. • With high speed, vibration free, and silent, during operation. • Various accessories available.
Additional MSM Type Features • Well illuminated digital display panel with sensitive touch buttons. • Convenient emergency stop. • Recognizable display modes : rpm, ratio%
Specifi cations & Ordering Informations
Model MSE-1 MSE-2 MSE-3 MSM-1 MSM-2 MSM-3
Technical Data
Speed control Scale AnalogSpeed range (rpm) Up to 1,400 Up to 1,200 Up to 900 50 ~ 1,400 50 ~ 1,200 50 ~ 900Display None DigitalStirring capacity (L, H2O) 20 30 50 20 30 50Torque, max. (N·cm) 15 27 53 15 27 53Power max. (W / A) 15 / 1.2 20.4 / 1.7 31.2 / 2.6 15 / 1.2 20.4 / 1.7 31.2 / 2.6
General Data
Body material Aluminum + PP
Dimensions (mm / inch, W×D×H)65×135×190 /2.56×5.31×7.48
70×150×200 /2.76×5.91×7.87
70×150×215 /2.76×5.91×8.46
65×135×190 /2.56×5.31×7.48
70×150×200 /2.76×5.91×7.87
70×150×215 /2.76×5.91×8.46
Net weight (Kg / lbs) 2 / 4.41 2.5 / 5.51 3 / 6.61 2 / 4.41 2.5 / 5.51 3 / 6.61Electrical requirements AC 100 ~ 240V, 50/60HzSafety device Thermal protection, Current protection, Emergency stop [MSM] Shaft die, max (mm / Inch) 3 ~ 10 / 0.12 ~ 0.39Protection class (DIN EN 60529) IP10
Cat. No.KR plug AAH372115K AAH372215K AAH372315K AAH370115K AAH370215K AAH370315KUS plug AAH372115U AAH372215U AAH372315U AAH370115U AAH370215U AAH370315U
※ Permissible environment condition : Temperature +5℃ ~ 40℃, Relative humidity up to 80%.※ Protection class according to DIN EN 60529 : Waterproof, Dust production index based on the test level.※ Above spec can be changed without prior notice.
Overhead Stirrer - Economic & Analog type
High dynamic stirring, simple operating, and sustainable economic benefits - for tasks of up to 50 liters [H2O]
Aluminum main body sturdy and efficiently absorbs the heat generated by the motor.
MSE types MSM types
Strirrers & Vortex Mixer
107
Overhead Stirrer - Digital type
Constructional Features • Compact and slim head design.
• Smooth start up and speed-down functions which prevent spills and splashing, controlled with a microprocessor
• PID feedback control system controls and maintains constant motor speed under conditions of changing viscosity.
• Powerful torque easy use with high viscosity samples.
• Aluminum main body sturdy and efficiently absorbs the heat generated by the motor.
• Well illuminated digital display panel with sensitive touch buttons.
• Selectable display modes: rpm, ratio%, motor temp, and run time.
• Convenient emergency stop.
• Recognizable overload and thermal protection for safe operation : sequenced-visible and audible alarms and stop systems.
• Speed adjustment dial knob.
• With high speed, vibration free, and silent, during operation.
• USB port comes standard. (Lab Companion exclusive software for control and data collection)
• Various accessories available.
Designed for optimum usability, strongest efficiency in the same class, and advanced safety system for protecting the user and laboratory environment.
Specifications & Ordering Informations
Model MSP-1 MSP-2 MSP-3
Technical Data
Speed control PID feedback controlSpeed range (rpm) 50 ~ 1,400 50 ~ 1,200 50 ~ 900Display DigitalStirring capacity, max. (L, H2O) 20 30 50Torque, max. (N·cm) 15 27 53Power max. (W / A) 15 / 1.2 20.4 / 1.7 31.2 / 2.6
General Data
Body material Aluminum + PP
Dimensions (mm / inch, W×D×H)65×135×190 /2.56×5.31×7.48
70×150×200 /2.76×5.91×7.87
70×150×215 /2.76×5.91×8.46
Net weight (Kg / lbs) 2 / 4.41 2.5 / 5.51 3 / 6.61Electrical requirements AC 100 ~ 240V, 50 / 60HzSafety device Thermal protection, Current protection, Emergency stop, Automatic speed-down (MSP)
Shaft die, max (mm / Inch) 3 ~ 10 / 0.12 ~ 0.39Protection class (DIN EN 60529) IP10
Cat. No.KR plug AAH371115K AAH371215K AAH37131KUS plug AAH371115U AAH371215U AAH37131U
※ Permissible environment condition : Temperature +5℃ ~ 40℃, Relative humidity up to 80%.※ Protection class according to DIN EN 60529 : Waterproof, Dust production index based on the test level. ※ Above spec can be changed without prior notice.
MSP types
Strirrers & Vortex Mixer
108
Vortex Mixer
Constructional Features • Well-balanced and designed vortex mixer, with optimized safety
functions.
• Low-profile vortex mixer, with small footprint for used in lab benches, fume hoods, and clean benches.
• Touch sensitive switch offers real-time mixing. (B-type)
• Variable speed control knob, with different modes of mixing, and LED lighting to let the user which mode of mixing the vortex mixer is in. (B-type)
• Non spark BLDC motor safe, quick acceleration, and low mainte-nance.
• Built in safety device from overload and over current.
• Chemically resistant, PP (polypropylene) molded exterior.
• A wide range of accessories available. (VMS0011 accessories come standard)
Strirrers & Vortex Mixer
Specifications & Ordering Informations
Model VM-96B VM-96E
Technical Data
Motion OrbitalSpeed range (rpm) 0 - 3,000 200 - 3,000Display Analog NoneControl ScaleOrbit (mm / inch, Ø) 4 / 0.16Operating mode Touch, Continuous, High-continuous Touch, ContinuousMotor rating input / output (W) 12W / 6WMotor BLDC motorMax. load (kg / lbs) - incl. attachment 0.5 / 1.1
General Data
MaterialBody PolypropylenePlatform Silicone rubber
Dimension (mm / inch, W×D×H) 154×210×83 / 6.06×8.27×3.27 148×159×87 / 5.83×7.44×3.43Net weight (kg / lbs) 3.5 / 7.72 2.6 / 5.73Electrical requirements AC 100V ~ 240V, 50 / 60HzSafety Device Self-resetting / Current limit protection Current limit protectionProtection class (DIN EN 60529) IP 42
Cat. No.KR Plug AAH360115K
Parsian blue AAH361115BKYellow AAH361115YK
US Plug AAH360115UParsian blue AAH361115BUYellow AAH361115YU
※ Permissible environment condition : Temperature +5℃ ~ 40℃, Relative humidity up to 80%※ Protection class according to DIN EN 60529 : Waterproof, Dust production index based on the test level.
Intelligent 3 style operating modes allow user to select Touch, Continuous, High-continuous selective functions. - (VM-96B)
Easy converter operating mixer is designed for noiseless and powerful mixing that requires real-time control. (VM-96E)
109
Accessories & Options for Stirrers and Vortex Mixer
Egg Type Octagon Type
Plastic Retrievers(PE)
Polygon Type
Plastic Retrievers(teflon)
Strirrers & Vortex Mixer
for Magnetic Stirrer
Cat. No. Description mmMTT0001 Power Adapter for MS-12B & MS-17B 100 ~ 240V, 50 / 60HzMTT0002 Plate Cover (White, Silicone) for MS-12B Ø120MTT0003 Plate Cover (White, Silicone) for MS-17B/G Ø170MTT0004 Plate Cover (White, Silicone) for MS-22B/G Ø220MTT0005 Plate Cover (Black, Silicone) for MS-12B Ø120MTT0006 Plate Cover (Black, Silicone) for MS-17B/G Ø170MTT0007 Plate Cover (Black, Silicone) for MS-22B/G Ø220MTS0015 Silicone Plate for MS-53M 355×310MTS0016 Silicone Plate for MS-52M 235×310MTS0017 Silicone Plate for MS-51M 115×475MTS0041 Silicone Plate for MS-23M / 32M 355×310MTS0042 Silicone Plate for MS-33M 235×310MTT0008 Magnetic Stirring Bar (Octagon type) 12.7×8MTT0009 Magnetic Stirring Bar (Octagon type) 16.0×8MTT0010 Magnetic Stirring Bar (Octagon type) 22.0×8MTT0011 Magnetic Stirring Bar (Octagon type) 25.4×8MTT0012 Magnetic Stirring Bar (Octagon type) 28.6×8MTT0013 Magnetic Stirring Bar (Octagon type) 38.0×8
Cat. No. Description mmMTT0014 Magnetic Stirring Bar (Octagon type) 50.8×9.5MTT0015 Magnetic Stirring Bar (Polygon type) 15×5MTT0016 Magnetic Stirring Bar (Polygon type) 20×5MTT0017 Magnetic Stirring Bar (Polygon type) 25×5MTT0018 Magnetic Stirring Bar (Polygon type) 30×5MTT0019 Magnetic Stirring Bar (Polygon type) 40×5MTT0020 Magnetic Stirring Bar (Polygon type) 50×5MTT0021 Magnetic Stirring Bar (Egg type, 50ml Round flask) 16.0MTT0022 Magnetic Stirring Bar (Egg type, 10, 25, 50, 100ml Round flask) 19.0MTT0023 Magnetic Stirring Bar (Egg type, 100, 200ml Round flask) 25.4MTT0024 Magnetic Stirring Bar (Egg type, 300, 500ml Round flask) 31.8MTT0025 Magnetic Stirring Bar (Egg type, 500, 1000ml Round flask) 41.28MTT0026 Plastic Retrievers (PE) 300MTT0027 Plastic Retrievers (PE) 500MTT0028 Plastic Retrievers (Yellow, Teflon) 510MTT0029 Plastic Retrievers (Blue, Teflon) 510
for Vortex MixerCat. No. DescriptionVMS0008 Micro plate Tray
VMS0011 Rubber Platform
AAA36520 Tube Holder with Insert Retainer
AAA36521 Tube Holder with Insert Retainer (Ø10mm)
AAA36522 Tube Holder with Insert Retainer (Ø12mm)
AAA36523 Tube Holder with Insert Retainer (Ø15mm)
AAA36524 Tube Holder with Insert Retainer (Ø20mm)
AAA36525 Tube Holder with Insert Retainer (Ø25mm)
AAA36522
AAA36523VMS0008AAA36520
AAA36521
VMS0011
110
Accessories & Options for Overhead Stirrers
for Overhead Stirrers Impeller
Propeller Impeller
- Standard grade stainless steel with Teflon shaft produces an axial flow stir between the bot- tom and top levels of a sample with local shearing force. Used at medium or high speeds for mixing normal range level vis-cosity samples.
Radial Flow Impeller
- A radial flowing stir from the top and bottom levels of a sample with a powerful, high shearing turbulent force. Used ideally for the gassing of liquids and mixing medium to high range level vis-cosity samples.
Blade and Half-Moon Impeller
- Tiltable moon-shaped and bl-ade shaft produces a normal axial flow percentage mixing of samples. Used with round bo-ttom shaped containers, medium mixing speed, and samples ranging from low to medium viscosity levels.
Anchor and Paddle Impeller
- An anchored shaft that pro-duces a strong tangential flow with a high shearing percentage force on samples with medium to high viscosity level with speed setting in the low to medium range.
PTFE Impeller
Propeller Impeller Radial Flow Impeller Blade and Half-Moon Impeller Anchor and Paddle Impeller
Strirrers & Vortex Mixer
Cat. No. DescriptionAAA37521 Propeller (50mm 3-Bladed, 8mm Shaft, 400mm Length)
AAA37522 Propeller (70mm 3-Bladed, 8mm Shaft, 400mm Length)
AAA37523 Propeller (100mm 3-Bladed, 8mm Shaft, 400mm Length)
AAA37531 Propeller (50mm 4-Bladed, 8mm Shaft, 400mm Length)
AAA37532 Propeller (70mm 4-Bladed, 8mm Shaft, 400mm Length)
AAA37533 Propeller (100mm 4-Bladed, 8mm Shaft, 400mm Length)
AAA37541 Half-Moon (65/20mm , 8mm Shaft, 300mm Length)
AAA37542 Half-Moon (90/25mm , 8mm Shaft, 500mm Length)
BEA0570031 Dissolver (55mm, 8mm Shaft, 350mm Length)
BEA0570032 Dissolver (75mm, 8mm Shaft, 350mm Length)
AAA37551 Centrifugal (50/15mm, 8mm Shaft, 500mm Length)
AAA37552 Centrifugal (80/15mm, 8mm Shaft, 500mm Length)
AAA37561 Turbine (40mm, 8mm Shaft, 500mm Length)
Cat. No. DescriptionAAA37562 Turbine (70mm, 8mm Shaft, 500mm Length)
AAA37571 Anchor (45×45mm, 8mm Shaft, 300mm Length)
AAA37572 Anchor (60×60mm, 8mm Shaft, 500mm Length)
AAA37581 Paddle A (70×70mm, 8mm Shaft, 500mm Length)
BEA0570081 PTFE Propeller (50mm 4-Bladed, 8mm Shaft, 500mm Length)
BEA0570082 PTFE Propeller (70mm 4-Bladed, 8mm Shaft, 500mm Length)
BEA0570091 PTFE Half-Moon (60 / 18mm , 8mm Shaft, 500mm Length)
BEA0570101 PTFE Centrifugal (76 / 17mm, 8mm Shaft, 500mm Length)
BEA0570111 PTFE Anchor (80×50×5mm, 8mm Shaft, 500mm Length)
BEA0570121 PTFE Anchor (80×40mm, 8mm Shaft, 500mm Length)
BEA0570131 PTFE Turbine (70mm, 8mm Shaft, 500mm Length)
BEA0570141 PTFE Paddle (70mm, 8mm Shaft, 500mm Length)
BEA0570151 PTFE Paddle A (78×80mm, 8mm Shaft, 500mm Length)
111
Accessories & Options for Overhead Stirrers
for Overhead Stirrers
Clamp Holder Utility Clamp 3 Prong
Fixing Clamp Flexible Coupling
Utility Clamp Plat (2P)
3 Prong Clamp 2 Prong Clamp
PTFE Stirring seals
Clamp
Prong Clamp, Fixing Clamp, Flexible Coupling
PTFE Stirring seals
DS-01 Dial Stand
BS-03 Basic Stand BS-02 Basic Stand
Strirrers & Vortex Mixer
Cat. No. DescriptionAAA37501 DS-01 Dial Stand (W×D×H, 400×400×700)
AAA37502 BS-01 Basic Stand (W×D×H, 400×400×700)
AAA37503 BS-02 Basic Stand (W×D×H, 300×400×700)
AAA37504 BS-03 Basic Stand (W×D×H, 250×350×700)
MSS0051 SU-15 15Ø support, 500mm, M14 Nut
MSS0052 SU-18 18Ø support, 500mm, M14 Nut
MSS0053 SU-20 20Ø support, 500mm, M14 Nut
BEA0570161 PTFE Stirring seals (24 / 40)
BEA0570162 PTFE Stirring seals (29 / 42)
BEA0570163 PTFE Stirring seals (34 / 45)
Cat. No. Description
BEA0570171 Clamp Holder
BEA1000001 Utility Clamp 3 Prong
BEA1000002 Utility Clamp Plat (2P)
BEA1000011 3 Prong Clamp (80mm grip)
BEA1000012 3 Prong Clamp (60mm grip)
BEA1000013 3 Prong Clamp (20mm grip)
BEA1000014 2 Prong Clamp (60mm grip)
BEA0570181 Fixing Clamp
BEA0570191 Flexible Coupling
Environmental ChambersTemperature & Humidity Chambers. Temperature & Humidity Chambers - Tabletop type.Fingerprint Development Chamber - Tabletop type.Temperature Chambers.
Temperature Chambers - Tabletop type.Clean Temperature & Humidity Chambers. Plant Growth Chambers.
Selection GuideTemperature (& Humidity) Chambers
Description Operating Temp. Range 1) (℃/℉)
Operating Humid. Full Range 2) (%RH)
Chamber Volume (L / cu ft)
Page
Temperature & Humidity Chamber (Floor type)
TH-G Series -35 to 150 / -31 to 302
25 to 98 180 to 1500 / 6.4 to 53.0114 - 120TH-I Series 20 to 98 180 to 408 / 6.4 to 14.4
TH-GU-300 -60 to 150 / -76 to 302 25 to 98 300 / 10.6TH-TG Series -5 to 100 10 to 95 190 to 1500 / 6.7 to 53.0
123 - 127TH-ICH 3) Series -5 to 85 20 to 85 300, 760 / 10.6, 26.8
Temperature & Humidity Chamber (Tabletop type)
TH-KE Series -35~150 / -31~302 20 to 9525 to 100 / 0.9 to 3.53 128 - 134TH-ME Series -20 to 150 / -4 to 248 30 to 95
TH-PE Series 0 to 120 / 32 to 248 35 to 95TH-PF-100 4) 40 to 100 / 104 to 212 50 to 90 100 / 3.53 137 - 139
TemperatureChamber (Floor type)
TC-G Series -35 to 150 / -31 to 302 - 180 to 1500 / 6.4 to 53.0121 - 122
TC-GU-300 -60 to 150 / -76 to 302 - 300 / 10.6TemperatureChamber (Tabletop type)
TC-KE Series -40~150 / -40~302 -25 to 100 / 0.9 to 3.53 135 - 136
TC-ME Series -20 to 120 / -4 to 248 -
Clean Temperature& Humidity Chamber (Floor type)
TH-CR-270 -35 to 100 / -31 to 212 30 to 90 270 / 9.5 140 - 143
1) Operating Temperature Ranges obtained with using humidity.2) Please, refer to the specification details in the catalog.3) TH-ICH Series Temperature Ranges obtained w/o using light or humidity.4) Fingerprint development chamber.
Plant Growth Chambers
Description Operating Temp. Range 1) (℃/℉)
Operating Humid. Full Range (%RH)
Chamber Volume (L / cu ft)
Page
Plant Growth Chambers(Floor type)
GC-300TL 5 to 50 / 41 to 122- Lamp off10 to 50 / 50 to 122- Lamp on
- 300 / 10.6
146 - 148GC-300TLH50 to 90 300 / 10.6
1000 / 35.3GC-1000TLH
Accessories & OptionsDescription Page
for Temperature & Humidity Chambers 144for Plant Growth Chambers 149
General Applications
Safety functions1) Self-protecting cut-off function : - Over temperature, electrical leakage or overvo-
ltage automatically cuts the power from the unit, in an orderly fashion, starting with the heating element then the controller unit.
2) Time setting function for automated run / off : - Enable automatic start and shut off of a unit at
any specific time. - A timer can be set for a month and data can be
recorded in time, day, or week intervals.
3) Low fluid level protection water leakage alarm : - Intermittent toned alarm audible alarm and
visual alarms. - Water supply and circuit compartment separate
from each other to ensure safety.
4) Door-open warning alarm : - Intermittent toned alarm audible alarm and
visual alarms. - Heating element, fan, and platform automatically
stops when the door is opened to minimize heat loss and to ensure users safety.
Optimum control performance1) Microprocess PID control / Auto-tuning /
Calibration.
2) Optimize CPU logic control system. - Optimum control of temperature / humidity
with economical controls that reduces power consumption.
3) Touch screen type display. - 5.7-inch Color LCD display with interactive input
system. (only floor type) - Temperature & humidity / timer settings, and
operation condition. - Temperature, humidity, and other operating
parameters can be recorded using a chart recorder.
- Easily visible set value : set point (SP) / present value (PV) are also added on the colorful LCD controller.
Protect the global environment - Use of HFC refrigerant prevents damage to the
ozone layer. - Complies with the Montreal Protocol on Sub-
stances That Deplete the Ozone Layer control measures.
Temperature (& Humidity) ChambersTest for reliability, durability, climatic, freezing res-istance, quality assurance, thermal endurance etc. - Testing for electric and electronic component,
sensors. - Testing for semiconductor, PCB, LCD & LED. - Pharmaceutical tests. - Mechanical / Military / Aircraft engineering. - Automobile, Transport / automobile supply
industries. - Chemical / Petrochemical industries. - Construction materials / Plastic / Textile industries. - Testing mould, liquor, cigar, paintings. - Testing metal related industries like plating etc. - Ninhydrin, DFO and other fingerprint develo-
pment processes. (Only TH-PF-100)
Plant Growth Chamber - Agriculture experiment with growth of plants. - Growth experiment of animals and insects. - Food preservation experiments. - Genetic of life science researches. - Genetic researches and pathology of plants. - Retardation researches of seeds. - Tissue culture of plants and germinating
researches of seeds.
Technical Benefits
114
Temperature (& Humidity) Chambers
TH-G / TH-I / TC-G series
Environmental Chambers
Floor type
Certification only for the TH-G-180·300·408
Certification only for the TC-G-180·300·408
115
Temperature (& Humidity) Chambers
Dimensions(TH-G / TH-I / TC-G series)
Models Capacity W D H A BTH-GTH-ITC-G
180L (6.4cu ft) 1025mm (40.4”) 1035mm (40.7”) 1530mm (60.2”) 450mm (17.7”) 1230mm (48.4”)
300L (10.6cu ft) 1120mm (44.1”) 1070mm (42.1”) 1730mm (68.1”) 450mm (17.7”) 1230mm (48.4”)
408L (14.4cu ft) 1120mm (44.1”) 1240mm (48.8”) 1730mm (68.1”) 520mm (20.5”) 1230mm (48.4”)
TH-GTC-G
800L (28.3cu ft) 15700mm (61.8”) 1245mm (48.8”) 2060mm (81.1”) 490mm (19.3”) 1260mm (49.6”)
1000L (35.3cu ft) 15700mm (61.8”) 1445mm (56.9”) 2060mm (81.1”) 560mm (22.0”) 1260mm (49.6”)
1500L (53.0 cu ft) 1570mm (61.8”) 2045mm (80.5”) 2050mm (80.7”) 560mm (22.0”) 800mm (31.5”)
Temperature & Humidity control range(TH series only)
Relative Humidity % RH
TH-G-800/1000/1500
TH-G-180/300/408, TH-GU-300
TH-I-180/300/408
98%RH
95%RH
Temperature ℃
TH-G type (180, 300, 408L) TH-GU-300
• 40 ~ 85% RH at 15℃ • 25 ~ 98% RH at 25 ~ 80℃ • 25 ~ 80% RH at 90℃
TH-G type (800, 1000, 1500L)
• 50 ~ 90% RH at 20℃ • 45 ~ 95% RH at 25℃ • 40 ~ 95% RH at 30 ~ 80℃ • 40 ~ 80% RH at 90℃
TH-I type (180, 300, 408L)
• 30 ~ 80% RH at 10℃ • 20 ~ 90% RH at 20℃ • 20 ~ 98% RH at 25 ~ 80℃ • 20 ~ 80% RH at 90℃
Environmental Chambers
116
Temperature (& Humidity) Chambers
Operating & Constructional features User-friendly design
• Standard environmental test chambers.
• High quality #304 stainless steel exterior and interior.
• Casters for easy mobility when installing or moving environmental test chamber.
• Convenient maintenance-available to view total operating time.
• Spacious chamber volume maximum capacity of 1000L.
• Choose from 15 different model chambers based on size and temperature preference.
- The series comes in 3 different model types based on tempe-rature (&humidity) ranges ranging in -35℃ to 150℃, -35℃ to 120℃, -60℃ to 150℃ / upmost 20 to 98% RH and five different volume capacities of 180L, 300L, 408L, 800L, and 1000L.
• Unique door lock & trim. - Vice lock type door and foam silicone packing to ensure a perfect
seal. - Door open warning alarm.
• Inner door. - Optional inner glass door comes with four holes to handle samples
inside the chamber. (Excludes chambers with volume capacities of 800L or 1000L)
• Ventilation. - Ventilation vent is located at the upper right side of the unit.
• Chart recorder. (optional) - 6-point dot type recorder with a digital display.
• Container type tank for easy adding and changing of water. - Maintenance of the water tank can be easily performed from the
front side. - Checking of the water level and the amount of water remaining
in the tank can be performed by looking through the center viewing window.
• Viewing window for observation. - Tempered glass window provides a clear view of samples in the
chamber, beneficial during testing. - Fluorescent lighting source included.
• Cable port for external probes or wires. - 50mm diameter cable port comes standard on the left side of
the unit. Additional 50mm or 80mm diameter cable ports can be custom ordered. (Optional)
• Easy cleaning of condenser air-filter. - To prevent deterioration of refrigeration system and keep filter
dust free by periodically cleaning the filter.
Safety functions • Leakage breaker for power supply. • Over current protection. • Overheat / overcool protection. • Switch-off after alarm for over heating. • Water empty alarm. (TH-G / TH-GU / TH-I only)
• Door open alarm. • Vice lock door type locking mechanism.
Color LCD Controller
Digital Recorder (optional)
Door Catch & Trim
Environmental Chambers
117
Temperature (& Humidity) Chambers
Control operation • Microprocess PID control / Auto-tuning / Calibration.
• Chamber supports three different languages : English, Chinese, and Korean.
• Optimize CPU logic control system. - Optimum control of temperature / humidity with economical
power consumption.
• Touch screen type display. - 5.7-inch Color LCD display with interactive input system. : Easily visible set value: set point (SP) /present value (PV) are also
added on the colorful LCD controller. - Temperature & humidity / timer settings and operation condition. - Temperature, humidity, and other operating parameters can be
recorded using a chart recorder.
• Programming operation.
Description TH-G, I, GU /TC-G, GU series
Programmable pattern capacity 120Pattern repeat time 999Max. segments per a pattern 100Available max. segments* 1200Programmable process time per a segment 0 to 99 hr 59 min
* Even though the max. segments per a pattern are 100, available total seg-ments are up to 1200 not 12000, so you need to arrange the number of segment an patterns properly.
• Computer interface. - Save data in excel format. - Software provided. - Storage of program information, backup of value settings /
recovery, and temperature / humidity values. - RS-232C port as standard offer.
• RS-485 communication port offers connection of a maximum of 9 temperature & humidity chamber units to one PC. (optional)
Air filter
Ventilation
Water Tank
Single-control Display Multi-control Display
Program setting Display Graph Display
Environmental Chambers
118
Temperature & Humidity Chambers
Specifications & Ordering Informations
Model TH-G-180 TH-G-300 TH-G-408 TH-G-800 TH-G-1000 TH-G-1500Chamber volume (L / cu ft) 180 / 6.4 300 / 10.6 408 / 14.4 800 / 28.3 1000 / 35.3 1500 / 53.0Control system BDBC2 system - Balanced Dehumidifying & Bath Cooling controlController Programmable, Touch screen type controller (5.7” Color monitor)
Temperature
Range (±℃ / ℉)- without humidity
-35 to 150 / -31 to 302* best programmable control range : -30 to 140 / -22 to 284 -35 to 150 / -31 to 302
Fluctuation 1) (±℃ / ℉) at 55℃ / 60%RH 0.1 / 0.18 0.2 / 0.36 0.2 / 0.36 0.3 / 0.55 0.3 / 0.55 0.3
Variation 1) (±℃ / ℉) at 55℃ / 60%RH 0.6 / 1.08 0.5 / 0.9 0.5 / 0.9 0.5 / 0.9 0.5 / 0.9 0.5
Time
Heating - without humidity (Min.)
50 From -35℃ to 120℃ (-31℉ to 248℉) 60 From -35℃ to 120℃ (-31℉ to 248℉)
Cooling - without humidity (Min.)
60 From 20℃ to -35℃ (68℉ to -31℉) 85 From 20℃ to -35℃ (68℉ to -31℉)
On singe point control *
Humidity
Range (%RH)
40 to 85 at 15℃ (59℉) 50 to 90 at 20℃ (68℉) 25 to 98 at 25℃ to 80℃ (77℉ to 176℉) 45 to 95 at 30℃ to 80℃ (86 to 176℉) 25 to 80 at 90℃ (194℉) 40 to 80 at 30℃ to 90℃ (86 to 194℉)
Fluctuation 1) (±%RH) at 60%RH / 55℃ 0.3 0.4 0.3 0.5 0.6 3
Variation 1) (±%RH) at 60%RH / 55℃ 3.0 3.5
RefrigerationSystem Mechanical single stage refrigerator system
(air-cooled condenser)Mechanical dual stage refrigerator system (air-cooled condenser)
Refrigerant R-404A R-404A (1st step), R-23 (2nd step)
Capacity (W) 1500 4250 6000Cooler Plate fin cooler
HeaterMaterial Ni-Cr Wire Heater / SUS sheath Heater SUS Tube heater
Drying bulb (W) 2000 3000 5000Humidity bulb (W) 1500 2000 3500
SensorTemperature Pt 100Humidity Electronic sensor - Free of drying a wet pack and good reaction time
Material
Interior Stainless steel #304Exterior Stainless steel #304Insulation Polyurethane foam 100mm (3.94”)
Door Glass woolAir flow Tangent blower (90W) 4 sets of sirocco fan (4×90W)
Water supplyCapacity 15L (0.53cu ft) - Cartridge type Direct water supplying systemWater quality pH6.2 to 7.2 / Electrical conductivity 20㎲ /cm to below
Dimensions(W×D×H)
Interior (mm / inch)500×630×600/ 19.7×24.8×23.6
600×630×800/ 23.6×24.8×31.5
600×850×800/ 23.6×33.5×31.5
1000×800×1000/ 39.4×31.5×39.4
1000×1000×1000/ 39.4×39.4×39.4
1000×1000×1500 / 39.4×39.4×59.1
Exterior (mm / inch)1025×1035×1530/ 40.4×40.7×60.2
1120×1070×1730/ 44.1×42.1×68.1
1120×1240×1730/ 44.1×44.8×68.1
1570×1245×2060/ 61.8×49.0×81.1
1570×1445×2060/ 61.8×56.9×81.1
1570×2045×2050 / 61.8×80.5×80.7
Viewing windows(mm / inch) 200×330 / 7.9×13.0 270×330 / 10.6×13.0
Net weight (kg / lbs) 310±10 / 683.4±22.0 375±10 / 826.7±22.0 400±10 / 881.8±22.0 610±10 / 1345±22.0 670±10 / 1477±22.0 750±10 / 1653.5±22.0
Cable Port Basically one hole provided / Ø50mm (2.0”)Optionally max. two holes available / Ø50 or 80mm (2.0 or 3.2”)
Interface Port Basically RS-232C [RS-485(Maximum 9 Units Control)-Optional]
Electrical Requirements (230V, 60Hz) 1ph / 23.0A - -Cat. No. AAH80011 AAH80021 AAH80031 - - -Electrical Requirements (230V, 50Hz) 1ph / 23A 50Hz / 3ph / 22.5A 50Hz / 3ph / 37.7ACat. No. AAH80012 AAH80022 AAH80032 AAH80042 AAH80052 AAH80072KElectrical Requirements (380V, 50Hz) 3ph / 7.7A 50Hz / 3ph / 13.0A 50Hz / 3ph / 20.6ACat. No. AAH80018 AAH80028 AAH80038 AAH80048 AAH80058 AAH80078
1) Technical data. (according to DIN 12880, IEC 60068)※ Certification only for the TH-G-180∙300∙408※ Permissible ambient Condition: Temperature 18 to 30℃ (64.4 to 86℉), Maximum relative humidity 85%.※ All specifications are under ambient temperature 20℃ (68℉), no load.
Environmental Chambers
Certification only for the TH-G-180.300.408
119
Temperature & Humidity Chambers
Specifications & Ordering Informations
Model TH-I-180 TH-I-300 TH-I-408Chamber volume (L / cu ft) 180 / 6.4 300 / 10.6 408 / 14.4
Control system BDBC2 system - Balanced Dehumidifying & Bath Cooling control
Controller Programmable, Touch screen type controller (5.7” Color monitor)
Temperature
Range (℃ / ℉) -35 to 150 / -31 to 302 without humidity
* best programmable control range : -30 to 140 / -22 to 284
Fluctuation 1) (±℃ / ℉) at 55℃ / 60%RH 0.1 / 0.18 0.2 / 0.36 0.2 / 0.36
Variation 1) (±℃ / ℉) at 55℃ / 60% 0.6 / 1.08 0.5 / 0.9 0.5 / 0.9
TimeHeating - without humidity (Min.) 50 From -35℃ to 120℃ (-31℉ to 248℉)
Cooling - without humidity (Min.) 60 From 20℃ to -35℃ (68℉ to -31℉) on singe point control *
Humidity
Range (%RH)
30 to 80 at 10℃ (50℉)
20 to 98 at 20 to 80℃ (68 to 176℉)
20 to 80 at 90℃ (194℉)
Fluctuation 1) (±%RH) at 60%RH / 55℃ 0.3 0.4 0.3
Variation 1) (±%RH) at 60%RH / 55℃ 3 3 3
Refrigeration
System Mechanical single stage refrigerator system(air-cooled condenser)
Refrigerant R-404A
Capacity (W) 1500
Cooler Plate fin cooler
Heater
Material Ni-Cr Wire Heater / SUS sheath Heater
Drying bulb (W) 2000
Humidity bulb (W) 1500
SensorTemperature Pt 100
Humidity Electronic sensor - Free of drying a wet pack and good reaction time
Material
Interior Stainless steel #304
Exterior Stainless steel #304
Insulation Polyurethane foam 100mm (3.94”)
Door Glass wool
Air flow Tangent blower (90W)
Water supplyCapacity 15L (0.53cu ft) - Cartridge type
Water quality pH6.2 to 7.2 / Electrical conductivity 20㎲ /cm to below
Dimensions(W×D×H)
Interior (mm / inch)500×630×600/ 19.7×24.8×23.6
600×630×800/ 23.6×24.8×31.5
600×850×800/ 23.6×33.5×31.5
Exterior (mm / inch)1025×1035×1530/ 40.4×40.7×60.2
1120×1070×1730/ 44.1×42.1×68.1
1120×1240×1730/ 44.1×44.8×68.1
Viewing windows (mm / inch) 200×330 / 7.9×13.0
Net weight (kg / lbs) 310±10 / 683.4±22.0 375±10 / 826.7±22.0 400±10 / 881.8±22.0
Cable Port Basically one hole provided / Ø50mm (2.0”)Optionally max. two holes available / Ø50 or 80mm (2.0 or 3.2”)
Interface Port Basically RS-232C [RS-485(Maximum 9 Units Control)-Optional]
Electrical Requirements (230V, 60Hz) 1ph / 23.0A
Cat. No. AAH80111 AAH80121 AAH80131
Electrical Requirements (230V, 50Hz) 1ph / 23.0A
Cat. No. AAH80112 AAH80122 AAH80132
Electrical Requirements (380V, 50Hz) 3ph / 7.7A
Cat. No. AAH80118 AAH80128 AAH80138
1) Technical data. (according to DIN 12880, IEC 60068)※ Permissible ambient Condition : Temperature 18 to 30℃ (64.4 to 86℉), Maximum relative humidity 85%※ All specifications are under ambient temperature 20℃ (68℉), no load.
Environmental Chambers
120
Temperature & Humidity Chambers Environmental Chambers
Specifications & Ordering Informations
Model TH-GU-300Chamber volume (L / cu ft) 300 / 10.6
Control system BDBC2 system - Balanced Dehumidifying & Bath Cooling control
Controller Programmable, Touch screen type controller (5.7” Color monitor)
Temperature
Range (℃ / ℉) -60 to 150 / -76 to 302 without humidity
*best programmable control range : -50 to 140 / -58 to 284
Fluctuation 1) (±℃ / ℉) at 40℃ / 60%RH 0.3 / 0.54
Variation 1) (±℃ / ℉) at 40℃ / 60%RH 0.5 / 0.9
TimeHeating - without humidity (Min.) 60 From -60℃ to 120℃ (-76℉ to 248℉)
Cooling - without humidity (Min.) 65 From 20℃ to -60℃ (68℉ to -76℉) on singe point control
Humidity
Range (%RH)
40 to 85 at 15℃ (59℉)
25 to 98 at 25 to 80℃ (77 to 176℉)
25 to 80 at 90℃ (194℉)
Fluctuation 1) (±%RH) 3
Variation 1) (±%RH) 3
Refrigeration
System Mechanical single stage refrigerator system (air-cooled condenser)
Refrigerant R-404A / R-23
Capacity (W) 3000
Cooler Plate fin cooler
Heater
Material Ni-Cr Wire Heater / SUS sheath Heater
Drying bulb (W) 2000
Humidity bulb (W) 1500
SensorTemperature Pt 100
Humidity Electronic sensor - Free of drying a wet pack and good reaction time
Material
Interior Stainless steel #304
Exterior Stainless steel #304
Insulation Polyurethane foam 100mm (3.94”)
Door Glass wool
Air flow Tangent blower (90W)
Water supplyCapacity 15L (0.53cu ft) - Cartridge type
Water quality pH6.2 to 7.2/ Electrical conductivity 20㎲ / cm to below
Dimensions(W×D×H)
Interior (mm / inch) 600×630×800 / 23.6×24.8×31.5
Exterior (mm / inch) 1120×1070×1730 / 44.1×42.1×68.1
Viewing windows (mm / inch) 200×330 / 7.9×13.0
Net weight (kg / lbs) 395±10 / 870.8±22.0
Cable Port Basically one hole provided / Ø50mm (2.0”)Optionally max. two holes available / Ø50 or 80mm (2.0 or 3.2”)
Interface Port Basically RS-232C [RS-485(Maximum 9 Units Control)-Optional]
Electrical Requirements (230V, 60Hz) 1ph / 23.0A
Cat. No. AAH80321
Electrical Requirements (230V, 50Hz) 1ph / 23.0A
Cat. No. AAH80322
Electrical Requirements (380V, 50Hz) 3ph / 7.7A
Cat. No. AAH80328
1) Technical data. (according to DIN 12880, IEC 60068)※ Permissible ambient Condition: Temperature 18 to 30℃ (64.4 to 86℉), Maximum relative humidity 85%.※ Upon request, other sizes of chambers are available. Please contact with us.※ All specifications are under ambient temperature 20℃ (68℉), no load.
121
Temperature ChambersEnvironmental Chambers
Specifications & Ordering Informations
Model TC-G-180 TC-G-300 TC-G-408 TC-G-800 TC-G-1000 TC-G-1500Chamber volume (L / cu ft) 180 / 6.4 300 / 10.6 408 / 14.4 800 / 28.3 1000 / 35.3 1500 / 53.0
Control system Cooling fuzzy control system
Controller Programmable, Touch screen type controller (5.7” Color monitor)
Temperature
Range (℃ / ℉) -35 to 150 / -31 to 302
Fluctuation 1) (±℃ / ℉) at 100℃ 0.2 / 0.36 0.1 / 0.18
Variation 1) (±℃ / ℉) at 100℃ 0.9 / 1.62 1.0 / 1.80 0.8 / 1.44 0.4 / 0.72 0.5 / 0.9 0.5 / 0.9
Time
Heating - without humidity (Min.)
50 From -35℃ to 120℃ (-31℉ to 248℉) 60 From -35℃ to 120℃ (-31℉ to 248℉)
Cooling - without humidity (Min.)
60 From 20℃ to -35℃ (68℉ to -31℉) 85 From 20℃ to -35℃ (68℉ to -31℉)
On singe point control
Refrigeration
System Mechanical single stage refrigerator system(air-cooled condenser)
Mechanical dual stage refrigerator system (air-cooled condenser)
Refrigerant R-404A R-404A (1st step), R-23 (2nd step)
Capacity (W) 1500 4250 6000
Cooler Plate fin cooler
HeaterMaterial Ni-Cr Wire Heater SUS TUBE Heater
Drying bulb (W) 2000 3000 5000
Sensor Temperature Pt 100
Material
Interior Stainless steel #304
Exterior Stainless steel #304
Insulation Polyurethane foam 100mm (3.94”)
Door Glass wool
Air flow Tangent blower (90W) 4 sets of sirocco fan (4×90W)
Dimensions(W×D×H)
Interior (mm / inch)500×630×600/ 19.7×24.8×23.6
600×630×800/ 23.6×24.8×31.5
600×850×800/ 23.6×33.5×31.5
1000×800×1000/ 39.4×31.5×39.4
1000×1000×1000/ 39.4×39.4×39.4
1000×1000×1500 / 39.4×39.4×59.1
Exterior (mm / inch)1025×1035×1530/ 40.4×40.7×60.2
1120×1070×1730/ 44.1×42.1×68.1
1120×1240×1730/ 44.1×44.8×68.1
1570×1245×2060/ 61.8×49.0×81.1
1570×1445×2060/ 61.8×56.9×81.1
1570×2045×2050 / 61.8×80.5×80.7
Viewing windows(mm / inch) 200×330 / 7.9×13.0 270×330 / 10.6×13.0
Net weight (kg / lbs)310±10 / 683.4±22.0
375±10 / 826.7±22.0
400±10 / 881.8±22.0
610±10 / 1345±22.0
670±10 / 1477±22.0
750±10 / 1653.5±22.0
Cable Port Basically one hole provided / Ø50mm (2.0”)Optionally max. two holes available / Ø50 or 80mm (2.0 or 3.2”)
Interface Port Basically RS-232C [RS-485(Maximum 9 Units Control)-Optional]
Electrical Requirements (230V, 60Hz) 1ph / 16.2A - -
Cat. No. AAH81411 AAH81421 AAH81431 - - -
Electrical Requirements (230V, 50Hz) 1ph / 16.2A 3ph / 22.5A 3ph / 28.5A
Cat. No. AAH81412 AAH81422 AAH81432 AAH81442 AAH81452 AAH81462K
Electrical Requirements (380V, 50Hz) 3ph / 5.2A 3ph / 11.5A 3ph / 15.2A
Cat. No. AAH81418 AAH81428 AAH81438 AAH81448 AAH81458 AAH81468K
1) Technical data. (according to DIN 12880, IEC 60068)※ Certification only for the TC-G-180∙300∙408.※Permissible ambient Condition: Temperature 18 to 30℃ (64.4 to 86℉), Maximum relative humidity 85%.※ All specifications are under ambient temperature 20℃ (68℉), no load.
Please visit .comFor further information on Jeio Tech´s Temperature Chamber products Information is readily available on our website.
Certification only for the TC-G-180.300.408
122
Temperature ChambersEnvironmental Chambers
Specifications & Ordering Informations
Model TC-GU-300Chamber volume (L / cu ft) 300 / 10.6
Control system Cooling fuzzy control system
Controller Programmable, Touch screen type controller (5.7” Color monitor)
Temperature
Range (℃ / ℉)-60 to 150 / -76 to 302 without humidity
*best programmable control range : -50 to 140 / -58 to 284
Fluctuation 1) (±℃ / ℉) at 40℃ 0.3 / 0.54
Variation 1) (±℃ / ℉) at 40℃ 0.5 / 0.9
TimeHeating (Min.) 60 From -60℃ to 120℃ (-76℉ to 248℉)
Cooling (Min.) 65 From 20℃ to -60℃ (68℉ to -76℉) on singe point control
Refrigeration
System Mechanical single stage refrigerator system (air-cooled condenser)
Refrigerant R-404A (1st step), R-23 (2nd step)
Capacity (W) 3000
Cooler Plate fin cooler
HeaterMaterial Ni-Cr Wire Heater
Drying bulb (W) 2000
Temperature Sensor Pt 100
Material
Interior Stainless steel #304
Exterior Stainless steel #304
Insulation Polyurethane foam 100mm (3.94”)
Door Glass wool
Air flow Tangent blower (90W)
Water supplyCapacity 600× 630×800 / 23.6×24.8×31.5
Water quality 1120×1070×1730 / 44.1×42.1×68.1
Dimensions(W×D×H)
Interior (mm / inch) 200×330 / 7.9×13.0
Exterior (mm / inch) 375±10 / 870.8 ±22.0
Viewing windows (mm / inch) Basically one hole provided / Ø 50mm (2.0”)
Net weight (kg / lbs) Optionally max. two holes available / Ø 50 or 80mm (2.0 or 3.2”)
Cable Port Basically one hole provided / Ø 50mm (2.0”)Optionally max. two holes available / Ø 50 or 80mm (2.0 or 3.2”)
Interface Port Basically RS-232C [RS-485(Maximum 9 Units Control)-Optional]
Electrical Requirements (230V, 60Hz) 1ph / 24.3A
Cat. No. AAH81521
Electrical Requirements (230V, 50Hz) 1ph / 24.3A
Cat. No. AAH81522
Electrical Requirements (380V, 60 / 50Hz) 3ph / 8.3A
Cat. No. AAH81528
1) Technical data. (according to DIN 12880, IEC 60068)※ Permissible ambient Condition: Temperature 18 to 30℃ (64.4 to 86℉), Maximum relative humidity 85%.※ All specifications are under ambient temperature 20℃ (68℉), no load.
123
Temperature & Humidity Chambers
TH-TG Series
Environmental Chambers
TH-ICH Series
Please visit .comFor further information on Jeio Tech´s Environmental Chamber products Information is readily available on our website.
Certification without TH-TG-1500
124
Temperature & Humidity Chambers
TEMPERATURE & HUMIDITY CONTROL RANGE TH-TG type (190 to 960L)
• 40~90% RH at 10℃
• 20~95% RH at 30℃
• 10~95% RH at 50~80℃
• 10~80% RH at 90℃
TH-TG type (1500L)
• 40~90% RH at 15℃
• 30~95% RH at 30℃
• 20~95% RH at 50~80℃
• 20~85 RH at 85℃
TH-ICH type (300, 760L)
• 40~80% RH at 15℃
• 30~85% RH at 30℃
• 20~85% RH at 50~85℃
Environmental Chambers
Dimensions(TH-TG / TH-ICH series)
Model Capacity W D H A BTH-TG-180 190L (6.7 cu ft) 880mm (34.6”) 945mm (37.2”) 1465mm (57.7”) 420mm (16.5”) 880mm (34.6”)
TH- TG -300 300L (10.6 cu ft) 1130mm (44.5”) 945mm (37.2”) 1520mm (59.8”) 420mm (16.5”) 905mm (35.6”)
TH-TG-408 410L (14.5 cu ft) 1130mm (44.5”) 1045mm (41.1”) 1520mm (59.8”) 520mm (20.5”) 905mm (35.6”)
TH-TG-800 760L (26.8 cu ft) 1220mm (48”) 1175mm (46.3”) 1965mm (77.4”) 520mm (20.5”) 1010mm (39.8”)
TH-TG-1000 960L (33.9 cu ft) 1220mm (48”) 1415mm (55.7”) 1965mm (77.4”) 635mm (25”) 1010mm (39.8”)
TH-TG-1500 1500L (53.0 cu ft) 1450mm (57.1”) 1900mm (74.8”) 2065mm (81.3”) 635mm (25”) 800mm (31.5”)
TH-ICH-300 300L (10.6 cu ft) 1130mm (44.5”) 985mm (33.8”) 1520mm (59.8”) 460mm (18.1”) 905mm (35.6”)
TH-ICH-800 760L (26.8 cu ft) 1220mm (48”) 1215mm (47.8”) 1965mm (77.4”) 545mm (21.5”) 1185mm (46.7”)
TH-TG-1500
TH-ICH 300/800
TH-TG-180/300/408/800/1000
125
The temperature & humidity chamber units comply with the ICH guidelines.Stability Testing Q1A (R2)-ICH, TG Chamber series.Photostability Testing Q1B (Option 2)-ICH Chamber series.
Temperature & Humidity Chambers
Constructional features • High quality #304 stainless steel exterior and interior.
• Casters for easy mobility when installing or moving environmental test chamber.
• Convenient maintenance. - Available to check total operating time.
• Unique door lock & trim.
• Vice lock type door and foam silicone packing to ensure a perfect seal.
• Cable port for external probes or wires.
• 50mm diameter cable port comes standard on the left side of the unit. Additional 50mm or 80mm diameter cable ports can be custom ordered. (Optional)
• Container type tank for easy adding and changing of water. - Maintenance of the water tank can be easily performed from the
front side.
• Door lock. (Optional)
• Cyclic defrost functions does not affect the temperature & humi-dity control for extended operation. (Under 15℃ set value)
• Powerful two sirocco fans maintains a constant airflow in the chamber.
Additional TH-ICH 300, 800 Features • In the event of a validation the apparatus correctly controls each
light and then transfers accurate data and is equipped with light sensors. (UV light sensor / VIS light sensor)
• Samples that have to be exposed to the light in which it is com-pletely near the UV energy of less than 200W-hr/m2 is provided to compare directly the results from overall intensity of less than 1.20 million lux-hr, drug substances and reagent.
• Total fluorescent lamp & UV lamp indicator and operating time indicator.
Safety Functions • Leakage breaker for power supply. • Over current protection. • Overheat protection. • Switch-off after alarm for over heating. • Door open alarm. • Water empty. • Vice lock door type locking mechanism. (Optional) • Alarm for completed Photostability Test. (Only TH-ICH series)
Control Operation • Microprocess PID control / Auto-tuning / Calibration.
• Digital LCD display with touch-sensitive 7 keypads.
• Easy operation with wide LCD screen. - Temperature & humidity / timer settings and operation condition.
• Program patterns are memorized for 10 years due to a battery built into the PCB.
• Expansion parameter inputs. (Conveniently display by letters)
• Programming operation.
• Computer interface. - Software provided. - Save data in excel format. - Storage of program information, backup of value settings /
recovery, and temperature / humidity values. - RS-232C port as standard offer.
• Chart recorder. (Optional) - 6-point dots type recorder with digital display. - Digital recorder. (6-Channels)
Environmental Chambers
126
Temperature & Humidity ChambersEnvironmental Chambers
Specifications & Ordering Informations
Model TH-TG-180 TH-TG-300 TH-TG-408 TH-TG-800 TH-TG-1000 TH-TG-1500Chamber volume (L / cu ft) 190 / 6.7 300 / 10.6 410 / 14.5 760 / 26.8 960 / 33.9 1500 / 53.0Controller PID control (LCD Type)
Temperature 1)
Range
Without humidity (℃ / ℉)
-5 ~ 100 / 23 ~ 212
With humidity (℃ / ℉)
+10 ~ 90 / 50 ~ 194 +15~85
Fluctuation 1) (±℃ / ℉)at 40℃ / 60%RH 0.3 / 0.55 0.5 / 0.9
Variation 1) (±℃ / ℉)at 40℃ / 60%RH 0.5 / 0.9 0.7 / 1.3 1.0 / 1.8
Humidity
Range (%RH)
FULL RANGE : 10 ~ 95%RH40 ~ 90 at 10℃ / 50℉30 ~ 95 at 20℃ / 68℉10 ~ 95 at 50℃ ~ 80℃ / 122℉ ~ 176℉10 ~ 80 at 90℃ / 194℉
FULL RANGE : 20~95%RH 40 ~ 90% RH at 15℃ (59℉) 30 ~ 95% RH at 30℃ (86℉) 20 ~ 95% RH at 50℃~80℃ (122℉ ~ 176℉) 20 ~ 85% RH at 85℃ (194℉)
Fluctuation 2) (±%RH) at 60%RH / 40℃ 2.0
Variation 2) (±%RH) at 60%RH / 40℃ 3.0
TimeHeating 4) 50min
(-5℃ 100℃)55min
(-5℃ 100℃)
Cooling 4) 120min(100℃ -5℃)
145min(100℃ -5℃)
RefrigerationSystem Air - cooledRefrigerant R- 404ACapacity (W) 150 250 250 470 470 470×2
Cooler Copper plate fin cooler
HeaterMaterial Ni-Cr Wire Heater / SUS Tube HeaterDrying bulb (W) 1000 1500 1500 2300 2300 3000Humidity bulb (W) 1000 1200 1200 2000 2000 2500
SensorTemperature Pt 100Humidity Electronic sensor (Free of drying a wet pack and good response time)
Air flow 2 set of sirocco fan (2×60 W) : Vertical type 4 set of sirocco fan(4×60W) : Vertical type
Material
Internal SUS #304 (2B polish)
External SUS #304 (Hairline finish) & Steel, 2.0t, Double painted & bakedInsulation Polyurethane (70mm / 2.76”)
Door GlasswoolOperating temperature 18℃ ~ 30℃ / 64.4℉~56℉, 85%RH (Non-corrosive and pure place)
Water tankCapacity (L / cu ft) 15 / 0.53 30 / 1.1Water quality pH6.2 ~ 7.2, Electrical conductivity 20㎲ / cm to below
Interface Port Basically RS-232C, [RS-485 : Optional]
Cable port Basically one hole provided / Ø 50mm (2.0”),Optionally max. two holes available / Ø 50 or 80mm (2.0 or 3.2”)
Viewing Window (mm / inch) 230×340 / 9.1×13.4 (Option)
Dimension(W×D×H)
Internal(mm / inch)
500×650×600 / 19.7×25.6×23.6
750×650×650 / 29.5×25.6×25.6
750×850×650/ 29.5×33.5×25.6
750×880×1160/ 29.5×34.6×45.7
750×1110×1160/ 29.5×43.7×45.7
1000×1000×1500 / 39.4×39.4×59.1
External(mm / inch)
880×945×1465 / 34.6×37.2×57.7
1130×945×1520/ 44.5×37.2×59.8
1130×1045×1520 / 44.5×41.1×59.8
1220×1175×1965 / 48.0×46.3×77.3
1220×1415 ×1965/ 48.0×55.7×77.4
1450×1900×2065 / 57.1×74.8×81.3
Net weight (kg / lbs) 220±10 / 485±22 250±10 / 485±22 280±10 / 617±22 360±10 / 794±22 410±10 / 904±22 480±10 / 1058±22
Electrical Requirements
AC230V, 1ph, 60Hz 13.1 A 15.4 A 15.4 A 24.5 A 24.5 A 30.5ACat.No. AAHC2001K AAHC2011K AAHC2021K AAHC231K AAHC2041K AAHC2051KAC230V, 1ph, 50Hz 12.4 A 14.7 A 14.7 A 23.5 A 23.5 A 29.2ACat.No. AAHC2002K AAHC2012K AAHC2022K AAHC2032K AAHC2042K AAHC2052K
1) All specifications are under ambient temperature 20℃ (68℉), no load.2) Technical data. (according to DIN 12880, IEC 60068)3) The value is measured on the center of chamber at the point of vertical direction.4) Up to 98% of the set value.※ Certification without TH-TG-1500
Certification without TH-TG-1500
127
Temperature & Humidity ChambersEnvironmental Chambers
Specifications & Ordering Informations
Model TH-ICH-300 TH-ICH-800Chamber volume (L / cu ft) 300 / 10.6 760 / 26.8Controller PID control (LCD Type)
Temperature 1)
Range
Without humidity (℃ / ℉)
-5 ~ 85 / 23~185 without Light0 ~ 85 / 32~185 with Light
With humidity (℃ / ℉)
+15 ~ 85 / 59~185 with Light
Fluctuation 1) (±℃ / ℉)at 40℃ / 60%RH 0.3 / 0.55 0.3 / 0.55
Variation 1) (±℃ / ℉)at 40℃ / 60%RH 0.5 / 0.9 0.7 / 1.3
Humidity
Range (%RH)
FULL RANGE : 20 ~ 85%RH40 ~ 80 at 15℃ / 59℉30 ~ 85 at 30℃ / 86℉20 ~ 85 at 50℃ ~ 85℃ / 122℉ ~ 185℉
Fluctuation 2) (±%RH) at 60%RH / 40℃ 3.0
Variation 2) (±%RH) at 60%RH / 40℃ 5.0
Light source(ICH Q1B option 2)
Cool white 3) 6,000 lux 6,500 luxUltraviolet-A 3) 4.5 W/㎡ 5.0 W/㎡
Light Uniformity VIS. : ±10% UVA : ±15%
VIS. : ±15% UVA : ±15%
Typical Time Required to Reach ICH Recommendation of 1.2 million lux-hr
≒ 200Hr ≒ 184Hr
Typical Time Required to Reach ICH Recommendation of 200 W-hr/m2
≒ 50Hr ≒ 40Hr
TimeHeating 4) 25min (20℃ 85℃) 30min (20℃ 85℃)
Cooling 4) 35min (20℃ -5℃) 40min (20℃ -5℃)
Refrigeration
System Air - cooledRefrigerant R- 404ACapacity (W) 250 470
Cooler Copper plate fin cooler
Heater
Material Ni-Cr Wire Heater / SUS Tube HeaterDrying bulb (W) 1500 2300 Humidity bulb (W) 1200 2000
SensorTemperature Pt 100Humidity Electronic sensor (Free of drying a wet pack and good response time)
Air flow 2 set of sirocco fan (2×60 W) : Vertical type
Material
Internal SUS #304 (2B polish)
External SUS #304 (Hairline finish) & Steel, 2.0t, Double painted & bakedInsulation Polyurethane (70mm / 2.76”)
Door EPDM SheetOperating temperature 18℃ ~ 30℃ / 64.4℉~ 56℉, 85%RH (Non-corrosive and pure place)
Water tankCapacity (L / cu ft) 15 / 0.53Water quality pH6.2 ~ 7.2, Electrical conductivity 20㎲ / cm to below
Interface Port Basically RS-232C, [RS-485 : Optional]
Cable port Basically one hole provided / Ø 50mm (2.0”),Optionally max. two holes available / Ø 50 or 80mm (2.0 or 3.2”)
Dimension(W×D×H)
Internal (mm / inch) 750×650×650 / 29.5×25.6×25.6 750×880×1160 / 29.5×34.6×45.7 External (mm / inch) 1130×985×1520 / 44.5×38.8×59.8 1220×1215×1965 / 48.0×47.8×77.4
Net weight (kg / lbs) 280±10 / 617±22 400±10 / 882±22
Electrical Requirements
AC230V, 1ph, 60Hz 15.4 A 24.5 ACat.No. AAHC1001K AAHC1011K
AC230V, 1ph, 50Hz 14.7 A 23.5 ACat.No. AAHC1002K AAHC1012K
1) All specifications are under ambient temperature 20℃ (68℉), no load.2) Technical data. (according to DIN 12880, IEC 60068)3) The value is measured on the center of chamber at the point of vertical direction.4) Up to 98% of the set value.
128
※ In the year of 2010, this products design can be changed without prior notice.
Temperature (& Humidity) Chambers - Tabletop type
TH-ME / TH-PE / TC-ME Series
Environmental Chambers
Please visit .comFor further information on Jeio Tech´s Environmental Chamber products Information is readily available on our website.
129
Temperature (& Humidity) Chambers - Tabletop type
Temperature & Humidity control range(TH-KE / ME / TH-PE series only)
TH-KE / ME type (25 to 100L)
• 45~75% RH at 15℃
• 20~95% RH at 40~80℃
• 20~90% RH at 90℃
TH-PE type (25 to 100L)
• 45~95% RH at 20℃
• 30~95% RH at 30~80℃
• 30~90% RH at 85℃
Relative Humidity % RH
95%RH
30% RH
20% RH85℃
90℃
Temperature ℃
TH-PE-025/065/100
TH-KE / ME-025/065/100
TH-PE-025/065/100TH-KE / ME-025/065/100 [Including TH-PE control range]
Environmental Chambers
Dimensions(TH-ME / TH-PE / TC-ME series)
Models Capacity W D H A B
TH-METH-PETC-ME
25L (0.9cu ft) 520mm (20.5”) 760mm (29.9”) 867mm (34.1”) 200mm (7.9”) 467mm (18.4”)
65L (2.3cu ft) 570mm (22.4”) 890mm (35.0”) 1010mm (39.8”) 235mm (9.3”) 540mm (21.2”)
100L (3.53cu ft) 650mm (25.6”) 1000mm (39.4”) 1050mm (41.3”) 263mm (10.4”) 557mm (21.9”)
TH-KE TC-KE
25L (0.9 cu ft) 610mm (24.0”) 855mm (33.7”) 920mm (36.2”) 220mm (8.7”) 498mm (19.6”)
65L (2.3 cu ft) 660mm (26.0”) 970mm (38.2”) 1065mm (41.9”) 258mm (10.2”) 570mm (22.4”)
100L (3.53 cu ft) 760mm (29.9”) 1070mm (42.1”) 1085mm (42.7”) 318mm (12.5”) 56.3mm (22.2”)
130
Operating & Constructional features(TH - KE / ME / PE series only)
User-friendly design • Small size & light weight.
• Compact design with high performance.
• Choose from 9 different model chambers based on size and temperature preference.
- The series comes in 3 different model types based on tempe-rature (& humidity) ranges ranging in -20℃ to 150℃, -0℃ to 120℃, -20℃ to 150℃ / upmost 20 to 95% RH and three different volume capacities of 20L, 65L, 100L.
• Efficient system with durable materials. - The evaporating system for better thermal efficiency with
corrosion-resistant materials. - The heating system with minimized potential heat when heating
or cooling for prompt reaction time and advanced performance.
• Water tank for easy water supply. - Maintenance can be done easily from the front side.
• Viewing window. - A tempered glass window provides a clear view of samples in the
chamber, beneficial during testing.
• Cable port for external probes or wires. - 50mm diameter cable port comes standard on the left side of
the unit. Additional 50mm or 80mm diameter cable ports can be custom ordered. (Optional)
• Optional stand for space-saving layout. - For use in limited spaces: stand & casters. ※ Be sure to secure the stand onto floor with earthquake resistant fitting
for your safety when using stand.
Safety functions • Leakage breaker for power supply. • Over current protection. • Overheat / overcool protection. • Switch-off after alarm for over heating. • Door open alarm. • Water empty alarm. (TH-ME / TH-PE)
Controller
Inner glass door
Portable Digital Recorder (optional)
Temperature (& Humidity) Chambers - Tabletop type
Environmental Chambers
Please visit .comFor further information on Jeio Tech´s Environmental Chamber products Information is readily available on our website.
131
Control operation • Microprocessor PID control / Auto-tuning / Calibration.
• Digital LCD display with touch-sensitive keys.
• Easy operation with wide LCD screen. - Temperature & humidity / timer settings and operating condition.
• Program patterns are memorized for 10 years due to a battery built into the PCB.
• Expansion parameter inputs. (displayed by letters)
• Programming operation.
Description TH-ME / PE, TC-ME seriesProgrammable pattern capacity 10
pattern repeat time 999
Max. segments pera pattern 100
Available max. segments* 100
Programmable process time pera segment 0 to 99 hr 59 min
* Even though the max. segments per a pattern are 100, available total segments are up to 300 not 3000, so you need to arrange the number of segment and patterns properly.
• Computer interface. (optional) - Software provided - Save data in excel format. - Storage of program information, backup of value settings /
recovery, and temperature / humidity values. - RS-232C port as standard offer.
• Chart Recorder. (optional) - 6 point dot type recorder with digital display.
• RS-485 communication port offers a maximum of 9 temperature humidity chambers to be connected by one PC. (optional)
Water Tank
Exclusive stand for the chamber
Multi-control Display Single-control Display
Program setting Display Graph Display
Temperature (& Humidity) Chambers - Tabletop type
Environmental Chambers
132
Temperature (& Humidity) Chambers - Tabletop type
Environmental Chambers
Specifications & Ordering Informations
Model TH-KE-025 TH-KE-065 TH-KE-100Chamber volume (L / cu ft) 25 / 0.9 65 / 2.3 100 / 3.53
Control system BDBC2 system - Balanced Dehumidifying & Bath Cooling control
Controller Program controller (LCD type)
Temperature 1)
Range (℃ / ℉) -35~150 / -31~302 without humidity +15~90 / 59~194 with humidity
Fluctuation2) (±℃ / ℉) at 50℃ / 60%RH 0.5 / 0.90
Variation2) (±℃ / ℉) at 50℃ / 60%RH 1.0 / 1.8
TimeHeating3) without humidity (Min.) 60 (-40℃ 100℃)
Cooling3) without humidity (Min.) 70 (25℃ -35℃)
Humidity
Range (%RH)
FULL RANGE : 20~95%RH 45~75 RH at 15℃ (59℉) 40~95 RH at 20℃ (68℉) 20~95 RH at 40~80℃ (104~176℉) 20~90 RH at 90℃ (194℉)
Fluctuation2) (±%RH) at 60%RH / 50℃ 2
Variation2) (±%RH) at 60%RH / 50℃ 3
Refrigeration
System Mechanical single stage refrigerator system (air-cooled condenser)
Refrigerant R-404A
Capacity (W) 470 656 750
Cooler Plate fin cooler (cooper)
Heater
Material Ni-Cr Wire Heater/SUS TUBE Heater
Drying bulb (W) 800 1000 1200
Humidity bulb (W) 800 1000 1200
SensorTemperature Pt 100
Humidity Electronic sensor - Free of drying a wet pack and good reaction time
Air flow (sirocco fan) 60W×1EA 60W×1EA 60W×2EA
Material
Internal Stainless steel #304 (2B polish)
External Stainless steel #304 & Steel, 0.8t, Double painted & baked
Insulation Polyurethane foam 100mm [3.94”]
Door Glasswool
Water tankcapacity (L / cu ft) 5.5 / 0.19 7.2 / 0.25 9.8 / 0.35
quality pH6.2 ~ 7.2, Electrical conductivity 20℃ / cm to below
Interface port BASICALLY RS-232C, [RS-485:OPTIONAL]
Cable port Basically one hole provided / Ø 50mm (2.0”) Optionally max. two holes available/ Ø 50 or 80mm (2.0 or 3.2”)
Dimension (W×D×H)
Internal (mm / inch)350×220×350 / 13.8×8.7×13.8
400×330×495 / 15.7×13.0×19.5
500×380×530 / 19.7×15.0×20.9
External (mm / inch)610×855×920 / 24.0×33.7×36.2
660×970×1065 / 26.0×38.2×41.9
760×1070×1085 / 29.9×42.1×42.7
Weight (kg / lbs) 110 ±10 / 242.5 ±22.0 140 ±10 / 308.6 ±22.0 150 ±10 / 330.7 ±22.0
Electrical Requirements
AC230V, 1ph, 60Hz 10.1A 12.4A 16A
Cat. No. AAH82411 AAH82421 AAH82431
AC230V, 1ph, 50Hz 9.7A 11.8A 15.6A
Cat. No. AAH82412 AAH82422 AAH82432
1) All specifications are under ambient temperature 20℃(68℉), no load 2) Technical data (according to DIN 12880, IEC 60068)3) Up to 98% of the set value※ Permissible ambient Condition: Temperature 18 to 30℃(64.4 to 86℉), Maximum relative humidity 85%※ Recommanded ambient temperature : +20℃(68℉)
133
Temperature (& Humidity) Chambers - Tabletop type
Environmental Chambers
Specifications & Ordering Informations
Model TH-ME-025 TH-ME-065 TH-ME-100Chamber volume (L / cu ft) 25 / 0.9 65 / 2.3 100 / 3.53
Control system BDBC2 system - Balanced Dehumidifying & Bath Cooling control
Controller Program controller (LCD type)
Temperature
Range (℃ / ℉) -20 to 120 / -4 to 248 without humidity
Fluctuation 1) (±℃ / ℉) at 25℃ / 60%RH 0.2 / 0.36 0.3 / 0.55 0.2 / 0.36
Variation 1) (±℃ / ℉) at 25℃ / 60% 0.3 / 0.55 0.3 / 0.55 0.3 / 0.55
TimeHeating - without humidity (Min.) 55 From -15℃ to 120℃ (5℉to 248℉)
Cooling - without humidity (Min.) 60 From 20℃ to -15℃ (68℉ to 5℉) on singe point control *
Humidity
Range (%RH)
FULL RANGE : 20~95%RH 45~75% RH at 15℃ (59℉) 40~95% RH at 20℃ (68℉) 20~95% RH at 40~80℃ (104~176℉) 20~90% RH at 90℃ (194℉)
Fluctuation 1) (±%RH) at 60%RH / 55℃ 1.6 0.4 0.5
Variation 1) (±%RH) at 60%RH / 55℃ 3 3 3
Refrigeration
System Mechanical single stage refrigerator system (air-cooled condenser)
Refrigerant R-404A
Capacity (W) 250 250 375
Cooler Plate fin cooler (cooper)
Heater
Material Ni-Cr Wire Heater / SUS sheath Heater
Drying bulb (W) 500 800 1000
Humidity bulb (W) 500 650 1000
SensorTemperature Pt 100
Humidity Electronic sensor - Free of drying a wet pack and good reaction time
Material
Interior Stainless steel #304
Exterior Steel, 1.0mm (0.04”) / Double painted & baked
Insulation Polyurethane foam 50mm (1.97”)
Door Glass wool
Air flow Sirocco fan (60W)
Water tankCapacity (L / cu ft) 5 / 0.18 6 / 0.21 9 / 0.32
Water quality pH6.2 to 7.2 / Electrical conductivity 20㎲/cm to below
Dimensions(W×D×H)
Interior (mm / inch) 350×220×350 / 13.8×8.7×13.8 400×330×495 / 15.7×13.0×19.5 500×380×530 / 19.7×15.0×20.9
Exterior (mm / inch) 500×760×850 / 19.7×29.9×33.5 550×890×1000 / 21.7×35.0×39.4 650×1000×1030 / 5.6×39.4×40.6
Net weight (kg / lbs) 80±5 / 176.0±11.0 110±5 / 242.0±11.0 130±5 / 286±11.0
Cable Port Basically one hole provided / Ø 50mm (2.0”)Optionally max. two holes available / Ø 50 or 80mm (2.0 or 3.2”)
Interface Port Basically RS-232C [RS-485 (Maximum 9 Units Control) - Optional]
Electrical Requirements (230V, 1ph, 60Hz) 9.6A 12A 14.4A
Cat. No. AAH82111 AAH82121 AAH82131
Electrical Requirements (380V, 1ph, 50Hz) 9.2A 11.1A 13.8A
Cat. No. AAH82112 AAH82122 AAH82132
1) Technical data. (according to DIN 12880, IEC 60068)
* 80mm cable access hole is NOT available for 25L chamber. (TH-ME-025)
* Above the dimensions are NOT included size of attached accessories.※ Permissible ambient Condition : Temperature 18 to 30℃ (64.4 to 86℉), Maximum relative humidity 85%※ All specifications are under ambient temperature 20℃ (68℉), no load.
Please visit .comFor further information on Jeio Tech´s Environmental Chamber products Information is readily available on our website.
134
Temperature (& Humidity) Chambers - Tabletop type
Environmental Chambers
Specifications & Ordering Informations
Model TH-PE-025 TH-PE-065 TH-PE-100Chamber volume (L / cu ft) 25 / 0.9 65 / 2.3 100 / 3.53
Control system BDBC2 system - Balanced Dehumidifying & Bath Cooling control
Controller Program controller (LCD type)
Temperature
Range (℃ / ℉) 0 to 120 / 32 to 248 - without humidity
Fluctuation 1) (±℃ / ℉) at 25℃ / 60%RH 0.2 / 0.36 0.3 / 0.55 0.2 / 0.36
Variation 1) (±℃ / ℉) at 25℃ / 60% 0.3 / 0.55 0.3 / 0.55 0.3 / 0.55
TimeHeating - without humidity (Min.) 40 From 0℃ to 120℃ (32℉ to 248℉)
Cooling - without humidity (Min.) 30 From 20℃ to 0℃ (68℉ to 32℉) on singe point control *
Humidity
Range (%RH)
FULL RANGE : 30~95%RH 45~95% RH at 20℃ (68℉) 30~95% RH at 30~80℃ (86~176℉) 30~90% RH at 85℃ (185℉)
Fluctuation 1) (±%RH) at 60%RH / 55℃ 1.6 0.4 0.5
Variation 1) (±%RH) at 60%RH / 55℃ 3 3 3
Refrigeration
System Mechanical single stage refrigerator system (air-cooled condenser)
Refrigerant R-404A
Capacity (W) 250 250 375
Cooler Plate fin cooler (cooper)
Heater
Material Ni-Cr Wire Heater/ SUS sheath Heater
Drying bulb (W) 500 800 1000
Humidity bulb (W) 500 650 1000
SensorTemperature Pt 100
Humidity Electronic sensor - Free of drying a wet pack and good reaction time
Material
Interior Stainless steel #304
Exterior Stainless steel, 1.0mm (0.04”) / Double painted & baked
Insulation Polyurethane foam 50mm (1.97”)
Door Glass wool
Air flow Sirocco fan (60W)
Water tankCapacity (L / cu ft) 5 / 0.18 6 / 0.21 9 / 0.32
Water quality pH6.2 to 7.2/ Electrical conductivity 20㎲/cm to below
Dimensions(W×D×H)
Interior (mm / inch)350×220×350 / 13.8×8.7×13.8
400×330×495 / 15.7×13.0×19.5
500×380×530 / 19.7×15.0×20.9
Exterior (mm / inch)500×760×850 / 19.7×29.9×33.5
550×890×1000 / 21.7×35.0×39.4
650×1000×1030 / 25.6×39.4×40.6
Net weight (kg / lbs) 80±5 / 176.0±11.0 110±5 / 242.0±11.0 130±5 / 286±11.0
Cable Port Basically one hole provided / Ø 50mm (2.0”)Optionally max. two holes available / Ø 50 or 80mm (2.0 or 3.2”)
Interface Port Basically RS-232C [RS-485 (Maximum 9 Units Control) - Optional]
Electrical Requirements (230V, 1hp, 60Hz) 9.6A 12.0A 14.4A
Cat. No. AAH82211 AAH82221 AAH82231
Electrical Requirements (380V, 1hp, 50Hz) 9.2A 11.1A 13.8A
Cat. No. AAH82212 AAH82222 AAH82232
1) Technical data. (according to DIN 12880, IEC 60068)
* 80mm cable access hole is NOT available for 25L chamber. (TH-PE-025)
* Above the dimensions are NOT included size of attached accessories.※ Permissible ambient Condition : Temperature 18 to 30℃ (64.4 to 86℉), Maximum relative humidity 85%※ All specifications are under ambient temperature 20℃ (68℉), no load.
135
Temperature Chambers - Tabletop type
Environmental Chambers
Specifications & Ordering Informations
Model TC-KE-025 TC-KE-065 TC-KE-100Chamber volume (L / cu ft) 25 / 0.9 65 / 2.3 100 / 3.53
Controller PID control (LCD Type)
Temperature1)
Range (℃ / ℉) -35~150 / -31~302 without humidity
Fluctuation2) (±℃ / ℉) at 50℃ ± 0.5°C
Variation2) (±℃ / ℉) at 50℃ ± 1.0°C
Time
heating3) without humidity (Min.)
60 (-40℃ 100℃)
cooling3) without humidity (Min.)
70 (25℃ -35℃)
Refrigeration
System Mechanical single stage refrigerator system (air-cooled condenser)
Refrigerant R-404A
Capacity (W) 470 565 657
Cooler Plate fin cooler (cooper)
HeaterMaterial Ni-Cr Wire Heater
Drying bulb (W) 1000 1200 1500
Temperature sensor Pt 100
Material
Internal Stainless steel #304 (2B polish)
External Stainless steel #304 & Steel, 0.8t, Double painted & baked
Insulation Polyurethane foam 100mm [3.94”]
Door Glasswool
Air flow (sirocco fan) 60W×1EA 60W×1EA 60W×2EA
Interface port BASICALLY RS-232C, [RS-485:OPTIONAL]
Cable port Basically one hole provided / Ø50mm (2.0”) Optionally max. two holes available / Ø50 or 80mm (2.0 or 3.2”)
Dimension (W×D×H)
Internal (mm / inch)350×220×350 / 13.8×8.7×13.8
400×330×495 / 15.7×13.0×19.5
500×380×530 / 19.7×15.0×20.9
External (mm / inch)610×855×920 / 24.0×33.7×36.2
660×970×1065 / 26.0×38.2×41.9
760×1070×1085 / 29.9×42.1×42.7
Weight (kg / lbs) 110 ±10 / 242.5 ±22.0 140 ±10 / 308.6 ±22.0 150 ±10 / 330.7 ±22.0
Electrical Requirements
AC230V, 1ph, 60Hz7.4A 8.8A 10.8A
AAH86111 AAH86121 AAH86131
AC230V, 1ph, 50Hz7.1A 8.4A 10.3A
AAH86112 AAH86122 AAH86132
1) All specifications are under ambient temperature 20℃(68℉), no load2) Technical data (according to DIN 12880, IEC 60068)3) Up to 98% of the set value※ Permissible ambient Condition: Temperature 18 to 30℃(64.4 to 86℉), Maximum relative humidity 85%
Recommanded ambient temperature : +20℃(68℉)
136
Temperature Chambers - Tabletop type
Environmental Chambers
Specifications & Ordering Informations
Model TC-ME-025 TC-ME-065 TC-ME-100Chamber volume (L / cu ft) 25 / 0.9 65 / 2.3 100 / 3.53
Control system Cooling PID control system
Controller Program controller (LCD type)
Temperature
Range (℃ / ℉) -20 to 120 / -4 to 248
Program control (℃ / ℉) -15 to 120 / -5 to 248
Fluctuation 1) (±℃ / ℉) at 100℃ 0.4 / 0.72 0.3 / 0.55 0.3 / 0.55
Variation 1) (±℃ / ℉) at 100℃ 2.0 / 3.60 1.9 / 3.42 1.8 / 3.24
TimeHeating (Min.) 55 From -15℃ to 120℃ (5℉ to 248℉)
Cooling (Min.) 60 From 20℃ to -15℃ (68℉ to 5℉) on singe point control *
Refrigeration
System Mechanical single stage refrigerator system (air-cooled condenser)
Refrigerant R-404A
Capacity (W) 250 250 375
Cooler Plate fin cooler (cooper)
HeaterMaterial Ni-Cr Wire Heater
Drying bulb (W) 800 1000 1000
Temperature Sensor Pt 100
Material
Interior Stainless steel #304
Exterior Stainless steel, 1.0mm (0.04”) / Double painted & baked
Insulation Polyurethane foam 50mm (1.97”)
Door Glass wool
Air flow Sirocco fan (60W)
Dimensions(W×D×H)
Interior (mm / inch)350×220×350 / 13.8×8.7×13.8
400×330×495 / 15.7×13.0×19.5
500×380×530 / 19.7×15.0×20.9
Exterior (mm / inch)500×760×850 / 19.7×29.9×33.5
550×890×1000 / 21.7×35.0×39.4
650×1000×1030 / 25.6×39.4×40.6
Net weight (kg / lbs) 80±5 / 176.0±11.0 110±5 / 242.0±11.0 130±5 / 286±11.0
Cable Port Basically one hole provided / Ø 50mm (2.0”)Optionally max. two holes available / Ø 50 or 80mm (2.0 or 3.2”)
Interface Port Basically RS-232C [RS-485 (Maximum 9 Units Control) - Optional]
Electrical Requirements (230V, 1ph, 60Hz) 5.3A 6.1A 6.8A
Cat. No. AAH86011 AAH86021 AAH86031
Electrical Requirements (380V, 1ph, 50Hz) 5.1A 6.0A 6.5A
Cat. No. AAH86012 AAH86022 AAH86032
1) Technical data. (according to DIN 12880, IEC 60068)
* 80mm cable access hole is NOT available for 25L chamber. (TC-ME-025)
* Above the dimensions are NOT included size of attached accessories.※ Permissible ambient Condition : Temperature 18 to 30℃ (64.4 to 86℉), Maximum relative humidity 85%※ All specifications are under ambient temperature 20℃ (68℉), no load.
137
Fingerprint Development Chamber
Temperature & Humidity control rangeRelative Humidity % RH
TH-PF -100
Temperature ℃
TH-PF-100 • 80 ~ 90% RH at 40℃
• 65 ~ 95% RH at 50℃
• 50 ~ 95% RH at 60℃
• 50 ~ 90% RH at 90℃
Fingerprint Development Chamber
Environmental Chambers
Please visit .comFor further information on Jeio Tech´s Environmental Chamber products Information is readily available on our website.
138
Exceptional design for Ninhydrin, DFO and other fingerprint development processes.Highly precise controlled microprocessor PID controller for rapid performance. Advanced safety features for protecting evidence. A clear display with LED light indicator and heated glass window.
Fingerprint Development Chamber
Fingerprint Development Chamber
Operating & Constructional features [Fingerprint Development Chamber]
Constructional Features • Small size & light weight.
• Compact design with high performance.
• Efficient system with durable materials. - The evaporating system for better thermal efficiency with
corrosion-resistant materials. - The heating system with minimized potential heat when heating
or cooling for prompt reaction time and advanced performance.
• Stainless steel interior. - High quality & Corrosion-resistant.
• Water tank for easy water supply. - Maintenance can be done easily from the front side.
(Optional Direct water system.)
• Large viewing window. - A tempered glass door provides a clear view of your specimen
during testing.
• Vice lock type door and foam silicone packing to ensure a perfect seal.
• Cable port for external probes or wires. - B50mm diameter cable port comes standard on the left side of
the unit. - Additional 50mm or 80mm diameter cable ports can be custom
ordered. (optional)
• Optional stand for space-saving layout. - For use in limited spaces: stand & casters. - Chambers can be stacked maximum two high. Be sure to secure the stand to the floor with an earthquake resistant
fitting for safety.
SAFETY FUNCTIONS • Key lockable door for your evidences. • Leakage breaker for power supply. • Over current protection. • Over heat protection. • Switch-off after alarm for overheating. • Automatic shut off after overheat alarm. • Low and empty water level alarm.
Control Operation • Intuitive Control Panel. - Sight Lamp, Window Clean, Water Level indicators.
• Microprocessor PID control / auto tuning / calibration. - Precise temperature & humidity control. - Faster fingerprint development. - Rapid recovery time after the door has been opened.
• Digital LCD display with touch-sensitive keys.
• Easy operation with wide LCD screen. - Temperature & humidity / timer settings and operating condition.
• Digital Timer with acoustic alarm. - Start / Stop button for easy operation. - Digital display for time remaining. - Set time expiring alarm.
• Programming operation.
• Program patterns are memorized for 10 years due to a battery built into the PCB.
• Expansion parameter inputs. (Conveniently display by letters.)
• Computer Interface. (optional) - Software provided. - Save data in excel format. - Storage of program information, backup of value settings /
recovery, and temperature / humidity values. - RS-232C port standard.
• Chart Recorder. (Optional) - 6-point dot type recorder with a digital display.
Control Board
Environmental Chambers
139
Fingerprint Development Chamber
Large window for viewing samples and with LED lighting on left and right of the interior door window.Heated glass window eliminates condensation.
Water Tank includedEasy maintenance.Direct water system. (Optional)
Key lockable doorfor your evidences.
Environmental Chambers
Specifications & Ordering Informations (Fingerprint development chamber)
Model TC-ME-025Chamber volume (L / cu ft) 100 / 3.53
Controller PID control (LCD Type)
Temperature
Range (℃ / ℉) 40 ~ 100 / 104 ~ 212
Fluctuation (±℃ / ℉) at 100℃ 0.5 / 0.9
Variation (±℃ / ℉) at 100℃ 0.5 / 0.9
Humidity
Range (%RH)
FULL RANGE : 50 ~ 90%RH80 to 90 at 40℃65 to 95 at 50℃50 to 90 at 90℃
Fluctuation (±%RH) 3.0
Variation (±%RH) 3.0
Heater
Material Ni-Cr Wire Heater / SUS cartridge Heater
Drying bulb 400W
Humidity bulb 400W
SensorTemperature Pt 100
Humidity Electronic sensor (free of drying a wet pack and good response time)
Air flow 2 set of sirocco fan (60W)
Material
Interior SUS #304 (2B polish)
Exterior SUS #304 & Steel, 1.0t, Double painted & baked
Insulation Polyurethane (70mm)
Door Glasswool
Water tankcapacity (L / cu ft) 9 / 0.32
quality pH6.2 ~ 7.2, Electrical conductivity 20㎲ / cm to below
Viewing Window (mm / inch) 280×430 / 11.02×16.9
Cable port Basically one hole provided / Ø 50mm (2.0”)Optionally max. two holes available/ Ø 50 or 80mm (2.0 or 3.2”)
Interface Basically RS-232C [RS-485 [Maximum 9 Units Control] - Optional]
Dimensions(W×D×H)
Interior (mm / inch) 500×380×530 / 1.97×15.0×20.9
Exterior (mm / inch) 670×845×1045 / 26.4×33.3× 41.15
Weight (kg / lbs) 115kg±5kg / 253.5±11.0
Electrical Requirements AC230V, 1ph, 60Hz 4.5A
Cat. No. AAH82331
Electrical Requirements AC230V, 1ph, 50Hz 4.3A
Cat. No. AAH82332
※ Permissible ambient conditions : Temperature 18 to 30℃(64.4 to 86.0℉), Maximum relative humidity 85%※ Recommended ambient temperature : +20℃(68℉)※ All specifications are under ambient temperature 20℃(68℉), no load.
140
Clean Temperature & Humidity Chambers
Temperature & Humidity control rangeRelative Humidity % RH
90% RH
TH-CR-270
85℃
Temperature ℃
TH-CR-270 • 50~90% RH at 20℃
• 40~90% RH at 30℃
• 30~90% RH at 40~85℃
TH-CR-270
Environmental Chambers
Please visit .comFor further information on Jeio Tech´s Environmental Chamber products Information is readily available on our website.
141
Clean Temperature & Humidity Chambers
User-friendly design • Standard clean environmental test chambers.
• Silicone-free safe construction.
• High quality type 304 grade stainless steel exterior and interior.
• Casters for easy mobility when installing or moving environmental test chamber.
• Convenient maintenance-available to view total operating time. - available to check total operating time.
• Unique door lock & trim. - Vice lock type door and foam silicone packing to ensure a
perfect seal. - Door open warning alarm.
• Inner door. - Optional inner glass door comes with four holes to handle
samples inside the chamber.
• Exhaust duct. - Exhaust duct is located at the upper right side of the unit.
• RChart Recorder. (optional) - 6 point dot type recorder with digital display.
• Container type tank for easy adding and changing of water. - Maintenance of the water tank can be easily performed from the
front side. - Checking of the water level and the amount of water remaining
in the tank can be performed by looking through the center viewing window.
• Viewing window. - Tempered glass window provides a clear view of samples in the
chamber, beneficial during testing. - Fluorescent lighting source included.
• Cable port for external probes or wires. - 50mm diameter cable port comes standard on the left side of
the unit. - Additional 50mm or 80mm diameter cable ports can be custom
ordered. (Optional)
• Easy cleaning of condenser air-filter. - To prevent deterioration of refrigeration system and keep filter
dust free by periodically cleaning the filter.
Dimensions(TH-CR-270)
Models Capacity W D H* A BTH-CR-270 270L (9.5 cu ft) 1180mm (46.5”) 1120mm (44.1”) 1935mm (76.1”) 325mm (12.8”) 1155mm (45.5”)
Operating & Constructional features
Inner chamber
Environmental Chambers
142
Capable for the best cleaned temperature and humidity chamber! By employing a HEPA filter and a top to bottom laminar air flow system, a class 100 controlled chamber is achieved.
Clean Temperature & Humidity Chambers
Control operation • Microprocess PID control / Auto-tuning / Calibration.
• Chamber supports three different languages : English, Chinese, and Korean.
• CPU logic control system. - Optimum control of temperature / humidity with economical
power consumption.
• Touch Screen Type Display. - 5.7-inch Color LCD display with interactive input system.
(only floor type) : Easily visible set value: set point (SP) / present value (PV) are also
added on the colorful LED controller. - Temperature & humidity, timer settings, and operation conditions. - Temperature, humidity, and other operating parameters can be
recorded using a chart recorder.
• Programming operation.
Description TH-CR-270Programmable pattern capacity 120
Pattern repeat time 999
Max. segments per a pattern 100
Available max. segments* 1200
Programmable process time per a segment 0 to 99 hr 59 min
* Even though the max. segments per a pattern are 100, available total segments are up to 1200 not 12000, so you need to arrange the number of segment and patterns properly.
• Computer interface. - Software provided. - Save data in excel format. - Storage of program information, backup of value settings /
recovery, and temperature / humidity values. - RS-232C port as standard offer. - RS-485 communication port offers connection of a maximum of
9 temperature & humidity chamber units to one PC. (optional)
Safety functions • Leakage breaker for power supply. • Over current protection. • Over heat protection. • Automatic shut off after overheat alarm. • Low and empty water level alarm. • Door opening alarm. • Vice lock door closing equipment.
Control Panel
Door Catch & Trim
Air-filter
Operating & Constructional features
Environmental Chambers
143
Clean Temperature & Humidity Chambers Environmental Chambers
Please visit .comFor further information on Jeio Tech´s Environmental Chamber products Information is readily available on our website.
Specifications & Ordering Informations (Fingerprint development chamber)
Model TH-CR-270Chamber volume (L / cu ft) 270 / 9.5
Control system BDBC2 system - Balanced Dehumidifying & Bath Cooling control
Controller Programmable, Touch screen type controller (5.7” Color monitor)Local controller (Fixed - command control)
Temperature
Range (℃ / ℉) -35 to 100 / -31 to 212
Fluctuation 1) (±℃ / ℉) at 40℃ / 60%RH 0.5 / 0.9
Variation 1) (±℃ / ℉) at 40℃ / 60%RH 0.5 / 0.9
TimeHeating - without humidity (Min.) 60 From -35℃ to 120℃ (-31℉ to 248℉)
Cooling - without humidity (Min.) 65 From 20℃ to -35℃ (68℉ to -31℉)
Humidity
Range (%RH)
50 to 90 at 20℃ (68℉)
40 to 90 at 30℃ (86℉)
35 to 90 at 40~85℃ (104~185℉)
Fluctuation 1) (±%RH) 3
Variation 1) (±%RH) at 60%RH 3
Cleanliness Class 100 (ISO 14644-1)
Refrigeration
System Mechanical single stage refrigerator system (air-cooled condenser)
Refrigerant R-404A
Capacity (W) 1500
Cooler Plate fin cooler
Heater
Material Ni-Cr Wire Heater / SUS sheath Heater
Drying bulb (W) 2000
Humidity bulb (W) 2000
SensorTemperature Pt 100
Humidity Electronic sensor - Free of drying a wet pack and good reaction time
Material
Interior Stainless steel #304
Exterior Stainless steel #304(Base & Control panels are made of Stainless steel with powder coating)
Insulation Polyurethane
Door Glass wool
*Silicon Free (optional)EPDM for door packing, chamber sealing and tubePoly Urethane for DI water inlet & drainage
Air flow Sirocco fan
Water supplyCapacity 15L (0.53cu ft) - Cartridge type
Water quality pH6.2 to 7.2 / Electrical conductivity 20㎲ /cm to below
Dimensions(W×D×H)
Interior (mm / inch) 600×700×648 / 23.6×27.6×25.4
Exterior (mm / inch) 1180×1120×1935 / 46.5×44.1×76.2
Viewing windows (mm / inch) 200×330 / 7.9×13.0
Net weight (kg / lbs) 400±10 / 881.8±22.0
Cable Port Basically one hole provided / Ø 50mm (2.0”)Optionally max. two holes available / Ø 50 or 80mm (2.0 or 3.2”)
Interface Port Basically RS-232C [RS-485 [Maximum 9 Units Control] - Optional]
Electrical Requirements (230V, 1ph) 60Hz / 29.0A 50Hz / 29.0A
Cat. No. AAH83011 AAH83012
Electrical Requirements (380V, 3ph) 50Hz / 9.6A
Cat. No. AAH83018
1) Technical data. (according to DIN 12880, IEC 60068)※ Permissible ambient Condition: Temperature 18 to 30℃ (64.4 to 86℉), Maximum relative humidity 85%※ All specifications are under ambient temperature 20℃ (68℉), no load.※ Upon request, other sizes of chambers are available. Please contact with us.
144
Accessories & Options for TH/ TC series
Viewing window • An observation window is only installed in the floor type chambers.
(TH/TC series and TH-CR-270 excludes TH-ICh series) A tempered dual window provides a clear of view of samples
during testing.
Inner door • An inner glass door comes installed with the clean temperature
& humidity chamber for quick viewing of samples and to prevent outside air from flowing in.
(Table top - without hand entry ports.)
Temperature and Humidity recorder • 6-point dot type recorder. • digital display.
Water supply • Water supply system for supplying pure water for humidification. - Maintenance of the water tank can be easily performed from the
front side.
Cable port • A through hole of 50 or 80mm dia. (2.0 or 3.2˝ dia.) is provided on
the wall of chamber to allow electrical cables to be introduced into the chamber. A 50mm hole is provided, maximum two holes (50 or 80mm) are optional.
Water purifier • Water purifier with reverse osmosis membrane. (optional)
Shelf • Wire and perforated type shelves (shelf brackets included) are made of
durable stainless steel. Standard shelves and shelf brackets come standard.
Warning signal light • A malfunction indicator can be placed on the right upper side.
Viewing window Inner door Recorder Warning signal light
Tabletop type chambers (TH-ME / TH-PE / TC-ME series / TH-PF-100)
Cat. No. DescriptionModels
TH-KE/ME/PE TH-PF TC-ME/KEAAA8T504 Portable recorder (6 points) • • •AAA8T506 Portable recorder (Digital, 6 channels) • • •AAA8T540 RS-232C interface converter included a cable (5m / 16.4ft) • • •AAA8T541 RS-485 interface converter included a cable (5m / 16.4ft) • • •AAA8T542 Interface cable (5m / 16.4ft) • • •AAA8T550 Warning signal lamp • • •RTD679 Wire shelf for TH / TC - KE / ME / PE - 025* • - •RTD680 Wire shelf for TH / TC - KE / ME / PE - 065 * • - •RTD681 Wire shelf for TH / TC - KE / ME / PE / PF - 100 * • • •AAA80602-6 Perforated shelf for TH / TC - KE / ME / PE - 025 * • - •AAA80602-7 Perforated shelf for TH / TC - KE / ME / PE - 065 * • - •AAA80602-8 Perforated shelf for TH / TC - KE / ME / PE / PF - 100 * • • •AAA8T612 Cable port (Ø 50mm / 2.0”) for TH / TC - ME / PE Series • • •AAA8T613 Cable port (Ø 80mm / 3.2”) for TH / TC - ME / PE Series • • •AAA8T610 Cable port (Ø 50mm / 2.0”) for TH / TC - KE Series • - •AAA8T611 Cable port (Ø 80mm / 3.2”) for TH / TC - KE Series • - •AAA80631 Stand for TH / TC - KE / ME / PE - 025 • - •AAA80632 Stand for TH / TC - KE / ME / PE - 065 • - •AAA80633 Stand for TH / TC - KE / ME / PE / PF - 100 • • •AAA80634 Two step stand for TH / TC - KE / ME / PE - 025 • - •AAA80635 Two step stand for TH / TC - KE / ME / PE - 065 • - •AAA8T621 Water purifier • • -RTD0794 Humidity sensor • • -CFA1910 Temperature sensor (RTD type) • • •
※ 80mm cable access hole is NOT available for 25L chamber. (TH-ME/PE-25, TC-ME-25)
Wire & Perforated shelves for Tabletop type chambers
ModelsDescription
Included* Maximum Space Dimensions (W×L)TH / TC - KE / ME / PE - 025 2 7 20mm (0.8”) 195×310mm (7.7×12.2”)TH / TC - KE / ME / PE - 065 2 10 20mm (0.8”) 280×360mm (11.0×14.2”)TH / TC - KE / ME / PE / PF - 100 2 10 20mm (0.8”) 330×460mm (13.0×18.1”)
* Only for wire shelf.
Environmental Chambers
145
Accessories & Options for TH/ TC series
Floor type chambers (TH-G / TH-I / TH-TG / TH-ICH / TC-G series)
Cat. No. DescriptionModels
TH-G TH-I TC-G TH-TG TH-ICH TH-CR 270AAA8T500 Recorder (6 points) • • • • • •AAA8T505 Recorder (Digital, 6 channels) • • • • • •AAA8T541 Interface converter included a cable (5m / 16.4ft) • • • • • •AAA8T542 Interface cable (5m / 16.4ft) • • • • • •AAA80550 Warning signal lamp • • • • • •AAA81552 Inner glass door (only for 180L chambers) • • • - - -AAA81551 Inner glass door (only for 270, 300, 408L chambers) • • • - - -EDA8212 Wire shelf for TH / TC - G / I - 180 • • • - - -EDA8213 Wire shelf for TH / TC - G / I - 300 • • • - - -EDA8214 Wire shelf for TH / TC - G / I - 408 • • • - - -EDA8215 Wire shelf for TH / TC - G - 800 • - - - - -EDA8216 Wire shelf for TH / TC - G - 1000, 1500 • - - - - -RTD1195 Wire shelf for TH-TG-180 - - - • - -RTD1196 Wire shelf for TH-TG / ICH-300 - - - • • -RTD1197 Wire shelf for TH-TG-408 - - - • - -RTD1198 Wire shelf for TH-TG / ICH-800 - - - • • -RTD1199 Wire shelf for TH-TG-1000, 1500 - - - • - -STT1040 Wire shelf for TH-CR-270 * - - - - - •AAA80602-1 Perforated shelf for TH / TC - G / I - 180 • • • - - -AAA80602-2 Perforated shelf for TH / TC - G / I - 300 • • • - - -AAA80602-3 Perforated shelf for TH / TC - G / I - 408 • • • - - -AAA80602-4 Perforated shelf for TH / TC - G - 800 • - - - - -AAA80602-5 Perforated shelf for TH / TC - G - 1000 , 1500 • - - - - -AAA80604-1 Perforated shelf for TH-TG-180 - - - • - -AAA80604-2 Perforated shelf for TH-TG / ICH-300 - - - • • -AAA80604-3 Perforated shelf for TH-TG-408 - - - • - -AAA80604-4 Perforated shelf for TH-TG / ICH-800 - - - • • -AAA80604-5 Perforated shelf for TH-TG-1000 / 1500 - - - • - -AAA80630-1 Perforated shelf for TH-CR-270 * - - - - - •AAA8T610 Cable port (Ø 50mm / 2.0”) • • • • • •AAA8T611 Cable port (Ø 80mm / 3.2”) • • • • • •AAA8T621 Water purifier • • - • • •AAA80622 Water cartridge tank • • - • • •RTD0794 Humidity sensor • • - • • •CFA1185 Temperature sensor (RTD type) • • • • • •RTD1190 Fluorescent Lamp(Cool White) for TH-ICH-300 - - - - • -RTD1191 Fluorescent Lamp(Cool White) for TH-ICH-800 - - - - • -RTD1188 UVA Lamp for TH-ICH-300 - - - - • -RTD1189 UVA Lamp for TH-ICH-800 - - - - • -AAA80680 THE-680 UV Sensor TH-ICH - - - - • -AAA80681 THE-681 Illumination Sensor for TH-ICH - - - - • -EDA9175 ULPA filter (optional) - - - - - •EDA9184 HEPA filter (1EA included) - - - - - •AAA80661 Door lock device - - - • • -AAA80620 Direct water system - - - • • -
Wire & Perforated shelves for Floor type chambers
ModelsDescription
Included* Maximum Space Dimensions (W×L)
TH / TC - G / I - 180 2 9 40mm (1.6”) 463×518mm (17.2×20.4”)
TH / TC - G / I - 300 2 10 40mm (1.6”) 518×558mm (20.4×22.0”)
TH / TC - G / I - 408 2 10 40mm (1.6”) 560×740mm (22.0×29.1”)
TH / TC - G / I - 800 2 14 40mm (1.6”) 750×960mm (30.0×37.8”)
TH / TC - G / I - 1000, 1500 2 14 40mm (1.6”) 950×960mm (37.4×37.8”)
TH-TG-180 2 7 60mm (2.4”) 458×608 (18×23.9)
TH-TG / ICH-300 2 8 60mm (2.4”) 708×608 (27.9×23.9)
TH-TG-408 2 8 60mm (2.4”) 708×808 (27.9×31.8)
TH-TG / ICH-800 2 17 60mm (2.4”) 708×718 (27.9×28.3)
TH-TG-1000, 1500 2 17 60mm (2.4”) 1008×708 (39.7×27.9)
TH-CR-270 2 10 40mm (1.6”) 640×558mm (25.2×22.0”)
* Only for wire shelf.※ In addition to providing standard accessories, we will manufacture customized accessories to meet your specific requirements. Contact us for details.
Environmental Chambers
146
Plant Growth Chambers
GC-1000TLH
Environmental Chambers
Please visit .comFor further information on Jeio Tech´s Temperature Chamber products Information is readily available on our website.
147
Plant Growth Chambers
Operating features • +5℃ to 50℃ (lamp off ) / 10℃ to 50℃. (lamp on)
• Max. to 35,000Lux for GC-1000.
• Max. to 20,000Lux for GC-300 series.
• 40 to 80% RH for GC-300TLH. (at 20~35℃) 50 to 90% RH for GC-1000TLH. (at 20~35℃)
• 300 to 5,000ppm CO2 control. (optional)
• Microprocessor PID control / Auto-tuning / Calibration.
• Digital timer: 1 min to 99 hr 59 min.
• Over-temperature limit / Door open alarm.
• 10 step programmable temperature, humidity, and illumination profiles and repeat the steps up to 999 cycles. (self-testing)
Constructional features • High quality #304 grade stainless steel interior and dirt repellent
powder coated exterior surface.
• User-friendly door system. - Silicone packing for keep inner chamber perfectly. - External door with magnetic sealing for dual airtight. - Smoothly open to minimize damage of samples.
• Wide inner tempered glass door provides a full view of the samples.
- A tempered window provides a clear view of your specimen during testing.
• Powerful air circulator for smooth airflow. - Air flow system very efficient for plant growth. - One propeller for GC-1000TLH / tangent blower and a sirocco
fan for GC-300 series.
• High frequency electronic ballast lamps. - Reinforced Blue and Red spectrums lighting system for plant
photosynthesis. - Economical with stable light and long life span. - Easy-to change bulbs.
• Heat rise restraint. - Unique construction to minimize the heat from rising due to the
luminous light source. - Designed to exhaust the heated air through the upper holes.
(only for GC-1000TLH)
• Easy cleaning of condenser air-filter. - To prevent deterioration of refrigeration system and keep filter
dust free by periodically cleaning the filter.
• Casters for easy mobility when installing or moving environmental testing chamber.
• Electronic humidity sensor is fast acting and easy to calibrate.
• Dual type water level sensor.
• Adjustable water tank positions. (only for GC-300TLH)
• Removable shelving and rounded inner chamber corners for easy cleaning.
Safety functions • Leakage breaker for power supply. • Over current protection. • Over heat protection with alarm. • Door opening alarm. • Low and empty water level alarm. (TLH models only)
Enough capacity, maximum 1000L to satisfy the user's plant growth needs.User-friendly programmable logic microprocessor, streamlined design, with optimized air flow and temperature flexibility.
Temperature setting graph
* 00:00 time value setting for the step 10 makes total number of step is 9 as the above graph.
Efficient airflow for plant growth
Environmental Chambers
148
Plant Growth Chambers
GC-300 lamp arrangement GC-1000 lamp arrangement
Lamps setting for GC-300
No. Lux (lx) Set valueson display Lamp diagram
1 1,500 0000 010 22 3,500 0000 101 1,33 5,500 0000 111 1,2,34 6,000 0101 010 2,4,65 8,000 0101 101 1,3,4,66 10,000 1010 010 2,5,77 12,000 1010 101 1,3,5,78 14,000 1111 010 2,4,5,6,79 17,000 1111 101 1,3,4,5,6,710 20,000 1111 111 1,2,3,4,5,6,7
※ Above the set values are measured at the center of chamber toward upside.
Lamps setting for GC-1000
No. Lux (lx) Set valueson display Lamp diagram
1 5,000 0101 000 4,6 (or 5,7)2 7,500 0000 010 23 9,500 1111 000 4,5,6,74 12,500 0101 010 2 with 4,6 (or 5,7)5 15,000 0000 101 1,36 18,500 1111 010 2,4,5,6,77 21,000 0101 101 1,3 with 4,6 (or 5,7)8 24,000 0000 111 1,2,39 28,000 1111 101 1,3,4,5,6,710 31,500 0101 111 1,2,3 with 4,6 (or 5,7) 11 35,000 1111 111 1,2,3,4,5,6,7
Environmental Chambers
Model GC-300TL GC-300TLH GC-1000TLHChamber volume (L / cu ft) 300 / 10.6 1000 / 35.3Control system Microprocessor PID controller
Temperature
Range (℃ / ℉)
5 to 50 / 41 to 122 - Lamp off 10 to 50 / 50 to 122 - Lamp on
20 to 50 / 68 to 122 - with humidity
Fluctuation (±℃ / ℉) at 25℃ 0.1 / 0.18 - without humidity
Variation (±℃ / ℉) at 25℃ 0.8 / 1.43 - without humidity
Illumination
Range (Lux) 0 to 20,000 0 to 35,000Control (steps) 10 11
Lamp Fl lamp (32W×18EA)FL lamp (32W×16EA)
Metal lamp (400W×3EA)
HumidityRange (RH %) -
40~80 at 20~35℃ 50~90 at 20~35℃
70~90 at 36~50℃ 60~90 at 36~50℃
Fluctuation (±RH)at 60% RH - 3
Co2(Optional)Range (ppm) 300 to 5,000Sensor NDIR CO2 sensor
Refrigerant (HP) 1/2 3/4Temp. heater power (W) 750×2EA 1,500×2EAHumid. heater power (W) - 1300 1500
Dimensions(W×D×H)
Interior (mm / inch) 510×540×1100 / 20.0×21.3×43.3 1200×800×1080 / 47.2×31.5×42.5Exterior (mm / inch) 700×805×1900 / 27.6×30.1×74.8 1410×1070×2150 / 55.5×42.1×84.7Net weight (kg / lbs) 250 / 551.2 550 / 1212.5
Electrical Requirements (230V) 60Hz / 12.5A 50Hz / 12.5A 60Hz / 16.0A 50Hz / 16.0A 60Hz / 30.0A 50Hz / 30.0A Cat. No. AAHA1011 AAHA1012 AAHA1021 AAHA1022 AAHA1031 AAHA1032
Lamps settingControl illumination values with the below lamp setting arrangements.
149
Accessories & Options for GC series
Wire Shelves
Cat. No.Description
ModelsIncluded Maximum Dimensions (W×L)
EDA8220 3 15 466×490mm (18.3×19.3”) GC-300TLGC-300TLH
EDA8222 6 30 770×580mm (30.3×22.8”) GC-1000TLH
Perforated Shelves
Cat. No.Description
ModelsIncluded Maximum Dimensions (W×L)
AAAA1511 - 15 466×490mm (18.3×19.3”) GC-300TLGC-300TLH
AAAA1512 - 30 770×580mm (30.3×22.8”) GC-1000TLH
Recorder
Models Description Cat. No.All GC series Recorder (6 points) AAA8T500
CO2 Control System
Models Description Cat. No.All GC series CO2 control system AAAA1521
※ In addition to providing standard accessories, we will manufacture customized accessories to meet your specifi c requirements. Contact us for details.
Wire shelves Perforated shelves
recorder CO 2 Sensor
Environmental Chambers
Flask Supports.Ultrasonic Cleaners.Magnetic Drives.
Other Products
General ApplicationsFlask Supports - Concave recessed, secure, and safe multi-volume flask holder.
Ultrasonic Cleaners- For cleaning laboratory, medical instruments/industrial micro goods/glasses, jewels.
Magnetic Drives - Blends, Biotech, Catalyst preparation, Food products, Fuels, Liquids, Solvents, Lacquers, Multiphase catalyic
reactions, Oils, Synthetic materials, Specialty chemicals, Polymers, Plymers, Slurries, Starches, Pulp and paper, Particle synthesis.
It's concave recessed, secure, and safe multi-volume flask holder.Convenient grip for easy carryingNoticeable name tag for classificationMulti-purpose holder also is able to hold ice.
Features • Flask size : 100ml, 250ml, 500ml, 1000ml, 2000ml • Chemically resistant to various organic solvents. • Material : PP (Polypropylene)
• Heat Resistance : -30℃ ~ +121℃ -22℉ ~ +249.8℉
Specifications & Ordering Informations
Model FT 010 13 FT 010 34 FT 025 12 FT 025 23Hole Capacity (ml) 100 100 250 250Hole (Dia, ×H) (mm / inch) 70×91 / 2.76×3.58 70×91 / 2.76×3.58 98×122 / 3.86×4.8 98×122 / 3.86×4.8
Dimensions (W×D×H) (mm / inch)
310×100×100 / 12.2×3.94×3.94
384×265×98/ 15.12×10.43×3.86
280×125×130/ 11.02×4.92×5.12
389×239×130/ 15.31×9.41×5.12
Cat. No. AAA23706 AAA23701 AAA23707 AAA23702
Model FT 050 12 FT 100 12 FT 200 12Capacity (ml) 500 1000 2000Hole (Dia, ×H) (mm / inch) 121×128 / 4.76×5.04 148×156 / 5.83×6.14 183×188 / 7.2×7.4
Dimensions (W×D×H) (mm / inch)
360×146×135/ 14.17×5.75×5.31
415×192×165/ 16.34×7.56×6.5
503×223×199/ 19.8×8.78×7.83
Cat. No. AAA23703 AAA23704 AAA23705
Flask SupportsOther Products
152
Ultrasonic Cleaners
UC-10 included cover and basket
UC-02 / UC-20
US-20 included cover and basket / Basket for UC/US series
Other Products
Please visit .comFor further information on Jeio Tech´s Ultrasonic Cleaner products Information is readily available on our website.
153 Features for UC series (ABS / PBT housing, SUS tank)
• Durable leakproof ABS / PBT housing and cover with 304 stainless steel tanks. • Maximum heater temperature is 70℃. (only 50℃ for UC-02)
• Digital LED display using splash-proof keypads: timer (1 to 99 min), temperature monitor. (UC-02 is only On/Off )
• High-frequency 40 kHz sound waves provide greater cleaning power and increased reliability. • Multiple frequency on 3 stages for both gentle cleaning and intensive cleaning. (without UC-02)
Specifications & Ordering Informations
Model UC - 02 UC - 10 [10P] UC - 20 [20P]Bath volume (L / cu ft) 2.0 / 0.07 10.0 / 0.35 20.0 / 0.70
Temperature range (℃ / ℉)Amb. ~ to 50Amb. ~ to 122 Amb. ~ to 70 / Amb. ~ to 158
Ultrasonic power (W) 70 200 [300] 400 [500]
Dimensions
Bath internal(W×L , D) (mm / inch)
142×132, 104/ 5.6×5.2, 4.1
300×240, 150/ 11.8×9.4, 5.9
495×292, 150/ 19.5×11.5, 5.9
Overall(W×L×H) (mm / inch)
290×210×200/ 11.4×8.4×7.9
490×368×297/ 19.3×14.5×11.7
721×451×297/ 28.4×17.8×11.7
Net weight (kg / lbs) 2.0 / 4.4 11.0 / 24.3 17.0 / 37.5Electrical Requirements (230V, 50 / 60Hz) 0.3A 0.9A (1.3A) 1.7A (2.2A)
Cat. No. BDH53015 BDH53045 (BDH53055) BDH53065 (BDH53075)
Electrical Requirements (120V, 50 / 60Hz) 0.6A 1.7A (2.5A) 3.3A (4.2A)
Cat. No. BDH53013 BDH53043 (BDH53053) BDH53063 (BDH53073)
Features for US series (Steel housing, SUS tank)
• All parts are made of durable 304 stainless steel tanks, cover and powder coating steel housing. • Maximum heater temperature is 70℃. • Digital LED display using splash-proof keypads: timer (1 to 99 min), temperature monitor. • High-frequency 40 kHz sound waves provide greater cleaning power and increased reliability. • Multiple frequency on 3 stages for both gentle cleaning and intensive cleaning.
Specifications & Ordering Informations
Model US-05 (05P) US-10 (10P) US-20 (20P)Bath volume (L / cu ft) 5.7 / 0.20 10.0 / 0.35 20.0 / 0.70Temperature range (℃ / ℉) Amb. ~ to 70 / Amb. w~ to 158Ultrasonic power (W) 150 [200] 200 [300] 400 [500]
Dimensions
Bath internal(W×L, D) (mm / inch)
300×150, 150/ 11.8×5.9, 5.9
300×240, 150/ 11.8×9.4, 5.9
495×292, 150/ 19.5×11.5, 5.9
Overall(W×L×H) (mm / inch)
380×236×300/ 15.0×9.3×11.8
360×300×300/ 14.2×11.8×11.8
565×360×300/ 22.2×14.2×11.8
Net weight (kg / lbs) 9.0 / 19.8 12.5 / 27.6 19.0 / 41.9
Electrical Requirements (230V, 50 / 60Hz) 0.7A (0.9A) 0.9A (1.3A) 1.7A (2.2A)
Cat. No. BDH53125 (BDH53135) BDH53145 (BDH53155) BDH53165 (BDH53175)
Electrical Requirements (120V, 50 / 60Hz) 1.3A (1.7A) 1.7A (2.5A) 3.3A (4.2A)
Cat. No. BDH53126 (BDH53136) BDH53146 (BDH53156) BDH53166 (BDH53176)
Ultrasonic Cleaners
Industrial B.L.T type ultrasonic transducer (Bolt Clamped Langevin Type Transducer) generates high-frequency sound waves that provide maximum cleaning power. UC/ US-P types are increased the frequency to improve cleaning ability.
Aggressive cleaning ability in a variety of sizes!
Other Products
Included Accessories • Cover • 304 stainless steel wire basket
Included Accessories • Cover • 304 stainless steel wire basket
154
Magnetic Drives
Magnetic drives are designed for agitating a fully vacuumed flask. Multi-functional easy to replace impeller.
Feature • Use of rare-earth elements which is Neodymium (Nd),
Samarium (Sm-Co) magnet. • High-speed rpm, vibration free. • Specifically designed with permanent magnets which has a
dynamic torque rating. • Small size and powerful rotating magnetic drive is useful both for
laboratory and manufacturing applications.
Magnetic Drive
Application of Magnetic Drive
Other Products
Specifications
Model MD-T6-24 MD-T6-29 MD-T6-34Ground joint 24 / 40 29 / 42 34 / 45
Material Body / Housing SUS316L / CR-PLATE
Bushing / Seal PTFE / Viton
Driving
Vacuum Max. 1×10-4 mmHg
Pressure Max. 5kg / cm2
Temp Max. 70℃ (without cooling), Max. 300℃ (with cooling)
Shaft size (Ø, mm) Ø8
Cooling in / out size (Ø, mm) Ø3.2
Dimension (Ø×L, mm) Ø50×200
Weight (kg / lbs) 1.02 / 2.25 1.04 / 2.29 1.08 / 2.38
Cat. No. BEA511001 BEA511002 BEA511003
156
Chemicals- Periodic Table
FranciumRadium
RutherfordiumDubnium
SeaborgiumBohrium
HassiumMeitnerium
UnunniliumUnununium
UnunbiumUnunquadium
UnunhexiumUnunoctium
87 (223)
88 (226)
104 (261)
105 (262)
106 (266)
107 (264)
108(277)109
(268)110
(281)111
(272)112
(285)114
(289)116
(289)118
(293)
FrRa
Ac-LrRf
DbSg
BhHs
MUun
UuuUub
UuqUuh
Uuo89-103
CesiumBarium
HafniumTantalum
TungstenRhenium
Osmiumlridium
PlatinumGold
MercuryThallium
LeadBismuth
PoloniumAstatine
Radon
55 132.91
56 137.33
72 178.49
73 180.95
74 183.84
75 186.21
76 190.23
77 192.22
78 195.08
79 196.97
80 200.59
81 204.38
82 207.20
83 208.98
84 (209)
85 (210)
86 (222)
CsBa
La-LuHf
TaW
ReO
sIr
PtAu
HgTl
PbBi
PoAt
Rn
RubidiumStrontium
yttriumZirconium
NiobiumMolybdenum
TechnetiumRuthenium
RhodiumPalladium
SilverCadmium
IndiumTin
AntimonyTellurium
IodineXenon
37 85.468
38 87.62
39 88.906
40 91.224
41 92.906
42 95.94
43 (98)
44 101.07
45 102.91
46 106.42
47 107.87
48 112.41
49 114.82
50 118.71
51 121.76
52 127.60
53 126.90
54 131.29
RbSr
YZr
NbM
oTc
RuRh
PdAg
CdIn
SnSb
TeI
Xe
PotassiumCalcium
ScandiumTitanium
VanadiumChromium
Manganeselrin
CobaltNickel
CopperZinc
GalliumGermanium
ArsenicSelenium
BromineKrypton
19 39.098
20 40.078
21 44.956
22 47.867
23 50.942
24 51.996
25 54.938
26 55.845
27 58.933
28 58.693
29 63.546
30 65.39
31 69.723
32 72.64
33 72.922
34 78.96
35 79.904
36 83.80
KCa
ScTi
VCr
Mn
FeCo
NiCu
ZnGa
GeAs
SeBr
Kr
SodiumMagnesium
3 IIIB
4 IVB
5 VB
6 VIIB
7 VIIB
89
1011
IB12
IBAluminum
SiliconPhosphorus
SulfurChlorine
Argon
11 22.990
12 24.305
13 26.982
14 20.086
15 30.974
16 32.065
17 35.453
18 39.948
NaM
gAl
SiP
SCl
Ar
LithiumBeryllium
BprpnCarbon
NitrogenOxygen
FluorineNeon
3 6.941
4 9.0122
5 10.811
6 12.011
7 14.007
8 15.999
9 18.998
10 20.180
LiBe
BC
NO
FNe
Hydrogen2
IIA13 IIIA
14 IVA15
VA16 VIA
17 VIIA
Helium
1 1.0079
2 4.0026
1 IA
18 VIIA
HH
e
57-71
ActiniumThorium
ProtactiniumUranium
NeptuniumPlutonium
AmerciumCurium
BerkeliumCalifornium
EinsteiniumFermium
MendeleviumNobelium
Lawrencium
89 (227)
90 232.04
91 231.04
92 238.03
93 (237)
94 (244)
95 (243)
96 (247)
97 (247)
98 (251)
99 (252)
100 (257)
101 (258)
102 (259)
103 (262)
AcTh
PaU
NpPu
AmCm
BkCf
EsFm
Md
NoLr
LanthanumCerium
PraseodymiumNeodymium
PromethiumSamarium
EuropiumGadolinium
TerbiumDysprosium
HolmiumErbium
ThuliumYtterbium
Lutetium
57 138.91
58 140.12
59 140.91
60 144.24
61 (145)
62 150.36
63 151.96
64 157.25
65 158.93
66 162.50
67 164.93
68 167.26
69 168.93
70 173.04
71 174.97
LaCe
PrNd
PmSm
EuGd
TbDy
HoEr
TmYb
Lu
VIIIB
LANTHANIDE SERIES
group
Period1
ACTINIDE SERIES
METAL
ALKALI METAL
ALKALINE EARTH METAL
TRANSITION METAL
LANTHANIDE SERIES
ACTINIDE SERIES
SEMIM
ETAL
NONMETAL
HALOGEN
NOBLE GAS
PERIODIC TABLE OF THE ELEMENTS KEY
STANDARD STATE
HeBr
LiTc
GASSOLID
SYNTHETICLIQUID
B5
10.81113 IIIA
Boron
GROUP IU PAC
ATOMIC NUM
BER
SYMBOL
ELEMENT NAM
E
GROUP GAS
RELATIVE ATOMIC M
ASSTechnical DataAppendix
157
Formulas, Conversions and Engineering Constants Conversion Factors
To Convert To... Multiply... By...Atmospheres (atm) Bar 0.9869
Atmospheres (atm) Inches Mercury (in Hg) 0.03342
Atmospheres (atm) Pounds/square inch (psi) 0.06805
Atmospheres (atm) Torr 0.001316
Bar Atmospheres (atm) 1.0133
Bar Pounds/square inch (psl) 0.06895
British Thermal Units (BTU) Joules (J) 0.000948
British Thermal Units (BTU) Kilowatt-hours (kWH) 3412
British Thermal Units (BTU) Watt-hours (WH) 3.412
British Thermal Units/hour (BTU/h) Kilocalories/hour (kcal/h) 3.969
British Thermal Units/hour (BTU/h) watts (W) 3.412
British Thermal Units+inches hour-square foot-℉
(BTU+in)(h-ft2-℉) watts/meter-℃ (W/m-℃) 6.933
British Thermal Units/pound (BTU/Ib) Kilojoules/kilogram (kJ/kg) 0.4299
British Thermal Units/pound-℉ (BTU/lb-℉) Kllojoules/kilogram-℃ (kJ/Kg-℃) 0.2388
Calories (cal) Joules (J) 0.2388
Centimeters (cm) Feet (ft) 30.48
Centimeters (cm) Inches (in) 2.54
Centimeters/second (cm/s) Feet/minute (FPM) 0.508
Cubic Centimeters (cm3or cc) Cubic feet (ft3) 28.320
Cubic Centimeters (cm3or cc) Cubic inches (in3) 16.39
Cubic Centimeters (cm3or cc) Milliliters (ml) 1.0
Cubic feet (ft3) Cubic meters (m3) 35.32
Cubic feet (ft3) Gallons, U.S. (gal) 0.1337
Cubic feet (ft3) Liters (I) 0.03532
Cubic feet/minute (CFM) Cubic meters/hour (m3/h) 0.5885
Cubic feet/minute (CFM) Cubic meters/second (m3/s) 2119
Cubic feet/minute (CFM) Liters/second (I/s) 2.119
Cubic inches (in3) Cubic centimeters (cm3 or cc) 0.061
Cubic meters (m3) Gallons, U.S. (gal) 0.003785
Cubic meters (m3) Liters (I) 0.001
Cubic meters (m3) Cubic feet (ft3) 0.02832
Cubic meters/hour (m3/h) Cubic feet/minute (CFM) 1.699
Cubic meters/hour (m3/h) Gallons/minute (GPM) 0.2271
Cubic meters/second (m3/s) Cubic feet/minute (CFM) 0.000472
Feet (ft) Centimeters (cm) 0.03281
Feet (ft) Meters (m) 3.281
Feet/minute (FPM) Centimeters/second (cm/s) 1.969
Feet/minute (FPM) Meters/second (m/s) 196.9
Gallons, imperial Gallons, U.S. (gal) 0.8327
Gallons, U.S (gal) Cubic feet (ft3) 7.481
Gallons, U.S (gal) Cubic meters (m3) 264.2
Gallons, U.S (gal) Gallons, imperial 1.201
Gallons, U.S (gal) Liters (I) 0.2642
Gallons/minute (gpm) Cubic meters/hour (m3/h) 4.403
Gallons/minute (gpm) Liters/second (l/s) 15.85
Grams (g) Ounces (oz) 28.35
Grams (g) Pounds (lb) 453.6
Grams/cubic centimeter (g/cm3) Kilograms/cubic meter (kg/m3) 0.001
Grams/cubic centimeter (g/cm3) Pounds/cubic fool (lb/ft3) 0.01602
Grams/cubic centimeter (g/cm3) Pounds/cubic inch (lb/in3) 27.68
Inches (in) Centimeters (cm) 0.3937
Inches (in) Millimeters (mm) 0.03937
Inches Mercury (in Hg) Atmospheres (atm) 29.92
Inches Mercury (in Hg) Torr 25.4
Technical DataAppendix
158
Technical DataAppendix
To Convert To... Multiply... By...Joules (J) British Thermal Units (BTU) 1055
Joules (J) Calories (cal) 4.187
Joules (J) Watt-hours (WH) 36.00
Joules/second (J/s) British Thermal Units/hour (BTU/h) 0.2931
Joules/second (J/s) Watts (W) 1
Kilocalories/hour (kcal/h) BTU/hour (BTU/h) 0.252
Kilograms (kg) Pounds (lb) 0.4536
Kilograms/cubic meter (kg/m3) Grams/cubic centimeter (g/cm3) 1000
Kilograms/cubic meter (kg/m3) Pounds/cubic foot (lb/ft3) 16.02
Kilograms/square centimeter (kg/cm2) Pounds/square inch (psi) 0.07031
kilojoules (kJ) Watt-hours (WH) 3.6
Kilojoules/kilogram (kJ/kg) British Thermal Units/pound (BTU/lb) 2.326
Kilojoules/kilogram-℃ (kJ/kg-℃) British Thermal Units/Pound-℉ (BTU/lb-℉) 4.187
Kilometers/hour (km/h) Miles/hour (MPH) 1.609
Kilopascals (kPa) Pounds/square inch (p8l) 6.895
Kilowatts (kW) British Thermal Units/hour (BTU/h) 0.0002931
Kilowatts (kW) Watts (W) 0.001
Kilowatt-hours (kWH) British Thermal Units (BTU) 0.0002931
Kilowatt-hours (kWH) Watt-hours (WH) 0.001
Liters (I) Cubic Feet (ft3) 28.32
Liters (I) Cubic Meters (m3) 1000
Liters (I) Gallons, U.S. (gal) 3.785
Liters/second (I/s) Cubic feet/minute (CFM) 0.4719
Liters/second (I/s) Gallons/minute (GPM) 0.06309
Meters (m) Feet (ft) 0.3048
Meters/second (m/s) Feet/minute (FPM) 0.00508
Miles/hour (MPH) Kilometers/hour (km/h) 0.6215
Millimrters (mm) Inches (in) 25.4
Newtons/square meter (N/m2) Pounds/square inch (psi) 6.895
Ounces (oz) Grams (g) 0.035274
Pounds (lb) Grams (g) 0.002205
Pounds (lb) Kilograms (kg) 2.205
Pounds/cubic foot (lb/ft3) Grams/cubic centimeter (g/cm3) 62.43
Pounds/cubic foot (lb/ft3) Kilograms/cubic meter (kg/m3) 0.06243
Pounds/cubic inch (lb/in3) Grams/cubic centimeter (g/cm3) 0.03613
Pounds/square inch (psi) Bar 14.504
Pounds/square inch (psi) Kilograms/square centimeter (kg/cm2) 14.22
Pounds/square inch (psi) Kilopascals (kPa) 0.145
Pounds/square inch (psi) Newtons/square meter (N/m2) 0.000145
Square centimeters (cm2) square feel (ft2) 929
Square centimeters (cm2) Square inches (in2) 6.452
Square feet (tt2) Square centimeters (cm2) 0.001076
Square feet (tt2) Square meters (m2) 10.76
Square inches (in2) Square centimeters (cm2) 0.155
Square meters (m2) Square feet (ft2) 0.0929
Torr Inches Mercury (in Hg) 0.03937
Torr Pounds/square inch (psi) 51.71
Watts (W) British Thormal Units/hour (BTU/h) 0.2931
Watts (W) Joules/second (J/s) 1
Watt-hours (WH) British Thermal Units (BTU) 0.2931
Watt-hours (WH) Joules (J) 0.0002778
Watt-hours (WH) Kilojoules (kJ) 0.2778
Watts/meter-℃ (W/m-℃) British Thermal Units incheshour-square foot-℉
(BTU+in)(h-ft2-℉) 0.1442
Watts/square centimeter (W/cm2) Watts/square inch (W/in2) 0.155
Watts/square inch (W/in2) Watts/square centimeter (W/cm2) 6.452
159
Formulas, Conversions and Engineering Constants
Technical DataAppendix
E
WR ER
E2
RE2
W
WI2
WI
WR
WE
EIEI
I2R
IR(Volts)
I(Amps)
R(Ohms)
W(Watts)
Volts Volts = Watts x Ohms
Volts = Watts Amperes
Volts = Amperes x Ohms
Amperes Amperes = Volts Ohms
Amperes = Watts Volts
Amperes = Watts Ohms
Watts Watts = Volts2
Ohms
Watts = Amperes2 x Ohms
Watts = Volts x Amperes
Wattage varies directly as ratio of voltages squared.
W2 = W1 E2 2
E1
3 Phase Amperes = Total Watts Volts x 1.732
Ohms Ohms = Volts Amperes
Ohms = Volts2 Watts
Ohms = Watts Amperes2
( )x
160
INDEX
AAir-Jacketed Incubators 44
Aspirators 68
Electric Water-Jet type 68
BBaths & Circulators 8
-Accessories 19-21
Cold Trap 18
Economy Heating 10
General Purpose Heating 12
Heating Bath Circulators 15
Refrigerated & Heating Bath Circulators 16
Shaking Heating 13
Ultrasonic Cleaning 152-153
Viscometer Heating 14
Benchtop
Baths 10-13
Baths & Circulators 10-16
Circulators 15
Clean Benches (Vertical type Laminar Flow) 26
Desiccators (Cubic & Round) 23-24
Ductless Fume Hood 31
Incubators 40-51
Ovens 58-66
Overhead 106-107
Pumps 68-69
Shakers 88-96
Stirrers 104-107
Temperature (& Humidity) Chambers 144-145
Ultrasonic Cleaners 152-153
Vortex Mixer 108
CCell Culture
Incubators 40-51
Incubated & Refrigerated & Illuminated Shakers 46-51
Low Temperature Incubators 42-45
Low Temperature Personal Incubators 45
Laboratory Refrigerators 82-84
Shaker 88-96
Stirrers, Stirrering Hot Plates, Hot Plates 104-108
Vortex Mixer 23
Chambers
Environmental 114-149
Incubators 40-51
Laboratory Refrigerators & Freezers 82-84
Low Temperature 121-122
Ovens 58-66
Plant Growth 146-149
Temperature & Humidity 114-149
Clean Temperature & Humidity 140-143
Circulators
Heating Bath 10-13
Refrigerated & Heating Bath 15-16
Clamps
Flask 19, 97
Separating Funnel 19, 97
for Overhead 111
Clean Benches
Vertical type Clean Benches 26
Cleaners
Ultrasonic 152-153
Cold Trap Baths (related with Vacuum Ovens) 18
Cooling Circulators 16-17
Covers for Baths
-Accessories 20
Chillers 72-77
-Accessories 78-79
161
INDEX
DDrying
Forced (Mechanical) Convection Ovens - Economic type 62
Gravity (Natural) Convection Ovens - Economic type 64
Forced (Mechanical) Convection Ovens 58-61
Gravity (Natural) Convection Ovens 63
Vacuum Ovens 66
Desiccators (Cubic & Round) 23-24
-Accessories 23
Ductless Fume Hood 30
-Accessories 33
EEnclosure
Vertical type Clean Benches 26
Environmental, Environmental Chambers
Incubators 40-51
Laboratory Refrigerators & Freezers 82-84
Low Temperature Incubators 42-45
Low Temperature 121-122
Ovens 58-66
Plant Growth Chambers 146-149
Temperature & Humidity Chambers 114-149
Benchtop (Tabletop) type 128-139
Floor type 66
Cleaned (HEPA Filtered) Floor type 118-121
Vacuum Ovens 51
FFingerprint Development Chamber 137-139
-Accessories 144
Forced Convection
Compact Incubators 45
Incubators 40-51
Ovens (Economy) 62
Ovens (General Purpose) 58-61
Flask Support 151
GGravity Convection
Incubators 40-51
Ovens (Economy) 64
Ovens (General Purpose) 63, 66
Growth Chambers
Plant 146-149
HHeating
Baths 10-13
Bath Circulators 15-16
Ovens 58-66
Incubators 40-51
Incubated Shakers 46-51
HEPA-Filtered
Laminar Flow (Vertical type) 26
Ductless Fume Hood 31
Temperature & Humidity Chambers 142-143
PCR Workstations 34-37
-Accessories 37
Hoods
Vertical type Clean Benches 26
- Accessories 29
Vertical type Laminar Flow 26
Ductless fume hood 31
- Accessories 33
Humidity
Temperature & Humidity Chambers 114-149
Plant Growth Chambers 146-149
PCR Workstations 34-37
-Accessories 37
UV Sterilization cabinet 34-37
-Accessories 37
162
IIlluminated
Incubated & Refrigerated Shakers 46-51
Plant Growth Chambers 146-149
Incubators
-Accessories 52-55
Air-Jacketed 44
Compact (Personal) 45
Economy 41
General Purpose 40
Low Temperature 42-45
Plant Growth 146-149
Shaking 46-51
LLaboratory Refrigerators & Freezers
-Accessories 69
General Purpose Laboratory Refrigerators 82-84
Pharmacy Refrigerator 82-84
General Purpose Laboratory Freezer 82-84
Low Temperature
Circulation Baths 16
Incubators 42-45
Incubated Shakers 46-51
Recirculating Coolers 74-77
Temperature Chamber 121-122133-135
MMagnetic Stirrers (MS-B/G/M) 104-105
-Accessories 109
Magnetic Drive 154
Mechanical Convection
Compact Incubators 45
Incubators 42-43
Ovens (Economy) 62
Ovens (General Purpose) 64
NNatural Convection 64
Incubators 40-51
Ovens (Economy) 64
Ovens (General Purpose) 63
OOpen-Rings Covers for Water Baths 20
Orbital Shaker
Incubating 46-51
Incubating & Refrigerating 46-51
Incubating & Refrigerating & Illuminating 46-51
Open-Air type (Platform) 91-94
Drying
Economy 62, 64
Forced (Mechanical) Convection 58-61
Gravity (Natural) Convection 63
Vacuum 66
Overhead 106-107
-Accessories 110-111
Vortex Mixer 108
-Accessories 109
PPerforated Shelves
for Incubators 52
for Plant Growth Chambers 149
for Ovens 65
for Temperature (& Humidity) Chambers 144-145
Platforms
Dedicated (for Shaking Water Baths) 19
Dedicated (for Shakers) 53
Platform Shakers 97
Universal (for Shaking Water Baths) 19
Universal (for Shakers) 97
Pumps
Rotary Vacuum 69
Rotary Vacuum Pumps 69
INDEX
163
RReciprocating Shakers
Incubating & Refrigerating & Illuminating 46-51
Separatory Funnel 96
Open-Air type (Platform) 88-96
Heating Baths 15
Recirculating Coolers 72-77
Basic type 78-79
General type
Intelligent type 16
Refrigerated 140-143
Bath Circulators 121-122
Clean Temperature & Humidity Chambers 133-135
Environmental Chambers 46-51
Incubating Shakers 46-51
Incubating & Illuminating Shakers 146-149
Incubating & Illuminating Plant Growth Chambers 121-122
Low Temperature Chambers 133-135
Low Temperature Incubators 42-45
Shakers 46-51
Temperature & Humidity Chambers
118-120126-127132-136142-143
Rotary Vacuum Pumps 69
SSeparatory Funnel Shakers 96
Shakers
-Accessories 97-99
Incubating 46-51
Incubating & Refrigerating 46-51
Incubating & Refrigerating & Illuminating 46-51
Open-Air type (Platform) 90-96
Orbital 90-93
Orbital / Reciprocating 92-94
Rocking 95
Reciprocating 92-93
Reciprocating Separatory Funnel 96
Reciprocating Heating Baths 13
Stainless Steel
Flat type Bath Covers 20
Spring Wire Racks for Baths 21
Spring Wire Racks for Shakers1) 95
Test Tube Racks for Baths 19
Test Tube Racks for Shakers1) 99
Stands
for Clean Benches (Table with Casters) 29
for Clean Benches (Basic Table) 29
for Benchtop Temp. & Humid Chambers (1 step) 144
for Benchtop Temp. & Humid Chambers (2 steps) 144
for Ductless Fume Hoods 33
for Laboratory Refrigerators & Freezers
for Overhead Stirrer 85
Stirring 104-107
Sterilization cabinets 34-37
TTable
for Clean Benches (Basic Table) 29
for Clean Benches (Table with Casters) 29
Tabletop
Baths 10-13
Baths & Circulators 15-16
Circulators 15-16
Clean Benches (Vertical type Laminar Flow) 26
Incubators 40-51
Ovens 61-66
Pumps 68-69
Shakers
Stirrers 90-96
Temperature (& Humidity) Chambers 128-139
Ultrasonic Cleaners 152-153
INDEX
164
Temperature Chambers
Cold Chambers 121-122
Growth Chambers 146-149
Incubators 40-51
Ovens 58-66
Temperature & Humidity Chambers
Benchtop (Tabletop) type 128-139
Floor type 114-127140-143
Cleaned (HEPA Filtered) Floor type 140-143
Tissue Culture
Incubators 40-51
Incubated Shakers 46-51
Incubated & Refrigerated Shakers 46-51
Incubated & Refrigerated & Illuminated Shakers 46-51
Low Temperature Incubators 42-44
Low Temperature Personal Incubators 45
Shaker 90-96
Stirrering 104-107
UUltrasonic Cleaners
Steel housing, Stainless Steel tank 152-153
ABS / PST housing, Stainless Steel tank 152-153
Universal Attachments (Utility Carriers) 97
for Shakers
Universal Platform 97
for Shakers (Dual) 19
for Shaking Heating Baths 19
YVacuum
Electric Aspirator 65
Ovens 66
Pumps 68-69
Silicone Gaskets for Vacuum Ovens (OV series) 67
Viton Gaskets for Vacuum Ovens (OV series) 67
Viscosity, Viscometer
Tube Holders 21
Heating Baths 15
Vortex Mixer 108
-Accessories 109
WWater Baths
-Accessories 19-21
Cold Trap 18
Economy 10
General Purpose 12
Heating Circulation 15
Refrigerated & Heating Circulation 15-16
Shaking 13
Ultrasonic Cleaning 152-153
Viscometer 14
Wire Shelves
for Oven 65
for Incubator 54
for Laboratory Refrigerators & Freezers 85
Work Surace for Ductless Fume Hoods 33
1) Need to be installed on an universal platform, which is sold separately.