Lab 8 Facebowxfer

download Lab 8 Facebowxfer

of 38

Transcript of Lab 8 Facebowxfer

  • 7/28/2019 Lab 8 Facebowxfer

    1/38

    Face-Bow Transfer& Mounting of Maxillary Cast

  • 7/28/2019 Lab 8 Facebowxfer

    2/38

    ArmamentariumFace-Bow

    NasionRelator

    Bard-Parker orLab KnifeOne sheet PinkBase-Pate Wax

    Face-Bow(Bite) Fork

    PlasterBowl forHot Water

    Toggle & ShaftHardware

  • 7/28/2019 Lab 8 Facebowxfer

    3/38

    Detailed Inventory of Facebow Device

  • 7/28/2019 Lab 8 Facebowxfer

    4/38

    Support Barower Frame

    JackScrew

    Facebow Apparatus

  • 7/28/2019 Lab 8 Facebowxfer

    5/38

    Adapting Wax to Bite-Fork

    1. Identify the top of

    the bite-fork

    2. Place two

    thicknesses of wax

    on the top

    3. Mould to form the

    wax in a horseshoe

    as illustrated

  • 7/28/2019 Lab 8 Facebowxfer

    6/38

    Use Bunsen Burner to Heat

    the Baseplate Wax

  • 7/28/2019 Lab 8 Facebowxfer

    7/38

    Warm the Wax in Hot Water

    Prior to this step, trythe horseshoe on

    the the maxillary

    cast to make sure

    all of the occlusalsurfaces of the

    maxillary teeth

    including the buccal

    cusps will beimprinted.

    Make sure the wax extends beyond the last molar in the arch

  • 7/28/2019 Lab 8 Facebowxfer

    8/38

    Insert & Align Bite Fork

    1. Align the bite

    fork with the

    mid-line of the

    maxilla

    2. Hold bite fork

    in place firmly

    as wax cools

  • 7/28/2019 Lab 8 Facebowxfer

    9/38

    Chill & Trim the Excess Wax

  • 7/28/2019 Lab 8 Facebowxfer

    10/38

    Assembling Hardware to

    Face-Bow

  • 7/28/2019 Lab 8 Facebowxfer

    11/38

    Use of Cotton Rolls

    Patient can assistin holding bite fork

    in place but must

    bite on cotton rolls

  • 7/28/2019 Lab 8 Facebowxfer

    12/38

    Initial Placement of Face-Bow

    1. After bite fork isrepositioned

    2. Gently guide the

    ear piece into the

    external auditory

    meatus

    3. Patient applies

    firmer pressureand holds in place

    while pulling

    forward at the

    same time

  • 7/28/2019 Lab 8 Facebowxfer

    13/38

    Initial Placement of Face-Bow

    4. Note toggle & shaft

    hardware are

    already attached to

    the face-bow at

    this stage

  • 7/28/2019 Lab 8 Facebowxfer

    14/38

    Nose Piece

    1. Center the plastic

    nose piece on the

    patients nasion.

    2. Tighten thumbscrew on the

    nasion-relator

    assembly

    3. This secures the

    vertical

    relationship in the

    sagittal plane

  • 7/28/2019 Lab 8 Facebowxfer

    15/38

    Attaching Hardware

    Loosely guide the

    vertical bar &

    horizontal cross

    bar to the bite fork

    shaft

    Have patient look at

    you. Make sure face

    bow is parallel to an

    imaginary line going

    between the pupils.

  • 7/28/2019 Lab 8 Facebowxfer

    16/38

    Attaching Hardware

    1. Make sure the

    horiz. cross bar

    is above thebite fork shaft

  • 7/28/2019 Lab 8 Facebowxfer

    17/38

    Attaching Hardware

    2. Tighten the

    T-screw on the

    vertical bar

    3. Tighten the

    horizontal -

    frontal T-screwas well

  • 7/28/2019 Lab 8 Facebowxfer

    18/38

  • 7/28/2019 Lab 8 Facebowxfer

    19/38

  • 7/28/2019 Lab 8 Facebowxfer

    20/38

  • 7/28/2019 Lab 8 Facebowxfer

    21/38

    >Removing the Face-Bow