L7000 User Manual
-
Upload
dante-luis-hahn -
Category
Documents
-
view
4 -
download
0
description
Transcript of L7000 User Manual
-
FPLock UserManual
Version:1.1
Date: Nov.2010
-
FPLockUserManualV1.0
2
AboutThisManual
This manual introduces the Fingerprint Lock (FP Lock) interface and menu
operations.Forthe FP Lockinstallation,seethe animation installationinstructions.
Ourproducts are subject to update from time to time, so our company
will neither make a commitment to guarantee the consistency between the
actual products and this document, nor assume any responsibility for any
disputearisingoutofthediscrepancybetweentheactualtechnicalparameters
andthismanual.Thisdocumentissubjecttochangewithoutpriornotice.
-
TableofContents
I
TableofContents
1.InstructionforUse.................................... 1
1.1FunctionsIntroduction.....................................................................1
1.2ListofInstallationAccessories.........................................................1
1.3FingerprintPressIntroduction..........................................................1
1.4DeviceAppearance..........................................................................1
1.5InstallationRequirements ................................................................1
1.5.1Precautions...............................................................................1
1.5.2UseBackupBattery ..................................................................2
1.5.3Backup(Emergency)MechanicalKey ......................................3
1.5.4ConvertofUnlockDirection.....................................................4
1.6Precautions......................................................................................1
1.7UserPrivileges ................................................................................1
1.8TimeSetting....................................................................................1
1.9OperationOvertime.........................................................................2
2.EnrollmentandVerification..................... 3
2.1EnrollinganAdministrator...............................................................3
2.1.1EnrollaFingerprint ..................................................................4
2.1.2EnrollaPassword .....................................................................5
2.2EnrollanOrdinaryUser...................................................................7
2.3BackupEnrollment..........................................................................9
2.4UserVerificationandSetNOStatus............................................... 10
2.5DeleteUserInformation ................................................................ 12
-
FPLockUserManualV1.0
II
3.LockFunctionandSettings.................... 15
3.1OperationSettings ......................................................................... 15
3.1.1OperateAlarmSetting ............................................................ 16
3.1.2IllegalTimes........................................................................... 16
3.1.3LockSetting ........................................................................... 17
3.1.4VerifyModeSetting................................................................ 17
3.1.5NormalOpenSetting .............................................................. 18
3.2LanguageSettings ......................................................................... 20
3.3 AdvancedSettings ......................................................................... 22
3.4BrowseSystemInformation........................................................... 24
3.5BrowseLogs ................................................................................. 26
3.6USBPenDriveManagement(Optional) ........................................ 27
4.OtherFunctions ...................................... 30
4.1RoutineOperationIndications........................................................ 30
4.2AdministratorLossPrevention....................................................... 30
4.3BatteryLowVoltageProtection ..................................................... 31
4.4ProgramAutomaticallyExitandPoweroff .................................... 31
5.Appendix:TechnicalSpecifications ....... 32
-
1. InstructionsforUse
1
1.InstructionsforUse
?Note: Functions marked with in this manual are only supported byspecificproductorcustomizedproduct, andwillbemarked afterthat.
1.1FunctionsIntroduction
1. Byimprovingtheperfectcombinationofbiometricsandcryptography,ourFP
Locksensuredoublesecuritythroughthefingerprintpluspasswordunlocking
feature.
2. TheOrganicLED(OLED)displayaffordsclearandbrightreadoutsthatmake
ourFPLocks intuitive andeasy touse.YoucanuseourFPLockswith ease
afterfollowingtheoperationinstructions.
3. Supports to set classified privileges for super administrators, administrators
andordinaryusers.
4. Supports deletionofallorthespecifiedregistered userdata.
5. Supports firmware upgrade, uploading/downloading of user information and
unlockingrecordsthrough the USBpendrive.
6. Supportsoffline browse of unlockingrecords.
7. Supportsaccuratedisplayoftimeanddate, withannualdeviation lessthantwo
minutes.
8. Supports temporary powersupplyof backupbattery.
9. You can set theFPLocks to be in theNormallyOpen (NO) state in special
cases.
10. Supports displayofthebatterychargeleveland triggerlowvoltagealarms.
11. Features anelectricclutchhandledesignwhichhelpseffectivelypreventtheFP
Lock failure caused by damage of the internal structure as a result of the
forceddestructionofthehandle.
-
FPLockUserManualV1.0
2
12. Supports single latch lock (both 60 mm and 70 mm locks) of American
standard,aswellas the deadboltlockmortise.
13. Themaximumcapacityis500fingerprints.Themaximumunlockingrecordis
30000logs.
14. Unlockmode:fingerprint,password,mechanicalkey.
-
1. InstructionsforUse
1
1.2ListofInstallationAccessories
2.Squareshaftofhandle
3.Mortise
4.Rubber
gasket
5.Rearholddow
nplate
6.Screw
7.Rearpanelassem
bly
8.Battery
9.Batterycover
16.Mountingpaper
14.Mechanicalkey
1.Frontpanelassembly
13.Backupbattery
12.Woodgrainscrew
11.Strikeplate
10.Strikebox
15.Installationdisk
-
FPLockUserManualV1.0
2
TableofInstallationAccessories
SN Name Quantity Unit Remarks
01 Front panelassembly 1 Set
02Squareshaftof
handle2 PCS
Oneneeded toselect baseon
thedoorthickness
03 Mortise 1 Set Single latch lock
04 Rubbergasket 2 PCSIncludingtheoneonthefront
panelassembly
05 Rearholddownplate 1 PCS
06 Screw 6 PCSTwo of screws needed toselect
base onthedoorthickness
07 Rearpanelassembly 1 Set
08 Battery 4 PCS FouralkalineAAbatteries
09 Batterycover 1 PCS
10 Strike box 1 PCS
11 Strikeplate 1 Set
12 Woodgrainscrew 4 PCS
13 Backupbattery 1 PCS 9V
14 Mechanical key 2 PCS
15 Installationdisk 1 PCS
16 Mountingpaper 1 PCS
-
1. InstructionsforUse
1
1.3FingerprintPressIntroduction
Enrollfingerprintbypressingindexfinger,middlefingerorringfinger(thumband
littlefingerareclumsy).
1) Properpress:
2) Improperpress:
The fingermustbe flat to thesurface and
centeredonthefingerprintsensor.
Slant Offcenter
Upright Offcenter
Please adopt the correct way to place the finger to avoid the poor
performanceof devicecauseby improperoperation.
-
1. InstructionsforUse
1
1.4DeviceAppearance
Frontview:
Numberkey1
(ESC key)
Fingerprintsensor
OLEDdisplay
Numberkey 3
( key)
Numberkey2
( key) Menu (Status indicator,
OKkey,Startkey)
Handle
Numberkey 4
Emergency powerport
-
FPLockUserManualV1.0
2
Rearview:
Numberkey1:Press thiskeytoexitcurrentoperation,pressandholdthiskeyto
powerofftheFPLock.Thenumberkey1doublesas ESC key.
Number key 2: This key is used to manually increase (when held this key, the
display values will rapidly increase) the setup value or navigate among menu
options.Thenumberkey2doublesas a key.
Number key 3: This key is used to manually decrease (when held this key, the
display values will rapidly decrease) the setup value or navigate among menu
options.Thenumberkey3doublesas a key.
Menukey(Statusindicator):ThiskeycanbeusedtostarttheFPLockpressand
holdthiskeyfor threesecondsontheinitialinterface toopenthemainmenuthis
keyalsodoublesasthe OK key.
The greenLED indicator blinkswhen the FPLock operates properly and the red
USB Port(optional)
Bandswitch
Handle
Batteries
Batterycover
-
1. InstructionsforUse
3
LEDindicatorisonforthreesecondsifanerroroccurs.ThegreenLEDindicatoris
onforthreesecondswhenanoperationsucceeds.
Band switch: If you cannot access the menu interface due to the loss of
administratorsforsomereasons,proceedasfollows:PressandholdtheMenukey
forthreesecondstodisplaytheadministratorverificationinterface,andthenturnthe
Bandswitchattherearofthelocktoleftorright,andopenupthemenuasasuper
administrator.
OLEDdisplay:TheblackandwhiteOLEDdisplayfeatureswhitegraphicsortext
againstablackbackground.
Fingerprint sensor: You can only collect or match fingerprint by pressing your
fingeronthefingerprintsensorwhenthelightinthefingerprintsensorwindowison
otherwisenothinghappenswhenyoupressyourfingeron thefingerprintsensor.
@Note: When you cannot power off the FP Lock due to the exception ofprogram,pressandholdtheESCkeytopoweroffandthenrestarttheFPLock.Itis
notrecommendedtopowerofftheFPLockby thisway whentheFPLockoperates
normally.
Emergencypowerport:Youcanadoptanexternalbackupbatterytoopenthelock
intheeventofunlockingfailureduetoinsufficientpowersupplyofthe FPLock.
Keyhole: Youcanuseamechanicalkeyforemergencydooropening.
USBport (optional): The USB port is used for firmware upgrade, uploading or
downloadinguserinformationand unlockingrecordsthroughaUSBpendrive.Only
somemodelshaveUSBportoptions.
-
1. InstructionsforUse
1
1.5InstallationRequirements
RecommendedTools:
You may need the following tools while following the instructions to install FP
Locks:
l Aruler.
l Amarkerpen.
l Adrillingtool.
l Acrossscrewdriver.
1.5.1Precautions
1.TheFPLockisapplicabletodoorsof3570mminthickness.Besuretolistyour
specialrequirementsorremarksforFPLocks tobe installedondoors thicker than
70mmbeforeplacinganorder.
2. Before ordering or installation of single latch lock, please confirm the
correspondingaccessories.
Single latch lock:
3.Pleaseconfirmthedooropeningdirections.Assumeyouarestandingoutsideand
facing a door and then there are four door opening directions: Left inward, left
outward, right inward and right outward. Left inward/outward means the door
swingsinward/outwardwithhingesontheleftrightinward/outwardmeansthedoor
swingsinward/outwardwithhingesontheright,asshowninthefollowingfigure:
-
FPLockUserManualV1.0
2
4.Ensurethecentralpointofthehandleisabout1meterabovethefloor.
5.Ensurealltheaccessoriesinstalledontherightposition.
6.Pleasefollowtheanimation instructionstoinstall FPLocks.
1.5.2BackupBattery
The FP Lock supports temporary use of external DC power for fingerprint or
passwordmatchingandunlocking.Butwhenitconnectedwithanexternalbattery,it
cannotprovide such functions as enrollment, deletionand setting, so as toprevent
dataloss asaresultofpowerinstability.
Asshownin thefigurebelow,connecta9VbatterytotheEmergencypowerportatthebottomof the FPLock,regardlessofpolarities.
-
1. InstructionsforUse
3
IfyoupoweroffaFPLockwithoutclosingthelockduringtheuseofexternalpower,
thelockmortisewillnotautomaticallyreturntoitsoriginalposition.Thatis,theFP
Lock remains inNOstate.To solve this problem,youcan replace thebattery and
thenverifytoopenthelockoncetohavethelockmortise back in position.
1.5.3Backup(Emergency)MechanicalKey
1. Removethescrewfromthelock
handle,and takeoffthehandle.
2.Insertthekey,turntorightor
left180tounlockthedoor.
-
FPLockUserManualV1.0
4
1.5.4ConvertofUnlockDirection
1.Remove the screw of handle, then
takeoffthehandleandrotate180.
2.Reloadthehandleandfixit
with the screw.
RubberGasket
-
1. InstructionsforUse
1
1.6Precautions
1.Westronglyrecommendyoutoenrollatleastoneadministratorafterinstallingthe
FPLock. Andthenyoucanenroll the ordinaryusers.
2.Donotremovebatterieswhenmatching,enrollingordeletingfingerprintsbecause
the sudden powerdown may result in data loss of FP Locks. Before removing
batteries,makesurethe FPLockisnotinworkingstate.
3. It is recommended to replace the FPLock batteries oncewithin sixmonths, to
avoidthedamagetothecircuitduetothebatteryleakage.Donotusebatterieswith
poorquality.
4.When installing a FP Lock, connect the plug to the socket properly. Improper
connectionmayleadto FPLockfailure.
-
1. InstructionsforUse
1
1.7UserPrivileges
Theuserprivilegesareclassifiedintothreetypes:Superadministrator,administrator
andordinaryuser.
Superadministrator:Refer touserswhohaveaccess to all system functions and
modifyallsystemsettings.
Administrators: Refer to who users who have access to all operations except
performingadvancedsettingsandenrollingsuperadministrator.
Ordinary users: Refer to all users other than the super administrators and
administrators. Ordinary users only have access to the fingerprint matching and
unlockingfunctions.
-
1. InstructionsforUse
1
1.8TimeSetting
You need to set the correct date and time when you first use of a FP Lock, the
operationsareas follows:
1)PowerontheFPLockbypressingtheMenukey
to open up the initial interface, as shown in the
figureontheleft.
?Note:The iconontheinitial interfaceis thebattery iconindicatinghowmuchchargeremains.Onthetoprightcorneroftheinitialinterface,thedisplay
alternatesbetweendate andtimeevery5seconds.
2)PressandholdtheMenukeyforthreesecondsto
access themenu interface.Theadministratorneeds
toverifyandthenmovetothestep3).Ifthereisno
administrator, moveto the step3) directly.
3) Press 2/3 to select Options. and then press
Menu.
4)Press2/3toselectSystemOpt.andthenpress
Menu.
02: 30: 30
FPLOCK
AdminAffirm
FPLOCK
Menu
UserManage
Options
PenDriveMng
Options
Operate Opt.
SystemOpt.
-
FPLockUserManualV1.0
2
5) Press 2/3 to select "Date Time" and then press
Menu.
6) Tomodify date or time, press 2/3 to move the
cursor to the desired option, and then press 2/3
again to enter correctdate or time.PressMenu to
saveyoursettings.
@Note:YoucansetthedatebetweenJanuary1st2003andDecember31st2032.To set the date beyond this range, you need to consult our commercial
representativesortechnicalsupportengineers.
1.9OperationOvertime
Inanyuseroperationstate,thedefaultovertimevalueis5seconds,after5seconds
thelockpowersoffautomatically.
SystemOpt.
DateTime
Language ENG
DevNum
YYYYMMDD24H200901019:34:29
ESC OK
-
2. Enrollment and Verification
3
2.EnrollmentandVerification
2.1EnrollinganAdministrator
If the FP Lock has no administrator, you must enroll at least one administrator
beforeenrollingordinaryusers.Toenrollanadministrator,proceedasfollows:
1)PowerontheFPLockbypressingtheMenukey
to open up the initial interface. Press andhold the
Menu todisplaythemenuinterface.
2) Press Menu to display the user management
interface.
3)Press2/3toselectEnrollAdminandthenpress
Menu.
Afterthat,theenrolledadministratorcanperformfingerprintor passwordenrollment,
theoperations are asfollows.
02:30:30
FPLOCK
Menu
UserManage
Options
PenDriveMng
UserManage EnrollUser
EnrollAdminDeleteUser
-
FPLockUserManualV1.0
4
2.1.1EnrollaFingerprint
4)EnterEnrollAdmininterface according to the
operationin 2.1EnrollanAdministratorsteps 1),2),
3). Press 2/3 to select Enroll FP and then press
Menu.
5) Press 2/3 to select Admin Accredit, and then
select Supervisor (Super administrator) or
Admin (Administrator). Press Menu to confirm
yourselection.
6) PressMenu tocontinue.
7) The system by default assigns unused user IDs
from 00001 and you may also manually enter an
unuseduserID.
8) Press the same finger on the fingerprint sensor
three consecutive times by adopting the proper
finger placement mode. For details, see 1.3
Fingerprint PressIntroduction.
EnrollAdmin EnrollFPEnrollPwd
AdminAccreditSupervisor
ESC OK
EnrollFPNewEnroll?
ESC OK
NewEnroll
UserID00001ESC OK
NewEnroll000010
PlaceFingerESC/EXIT
-
2. Enrollment and Verification
5
9) The system will prompt to save the enrollment
informationaftertheenrollmentissuccessful.Ifthe
enrollmentfails,thesystemwillprompttoreenroll
fingerprint.ThesystemreturnstotheNewEnroll
interface upon successful enrollment. You can
continue or exit the fingerprint enrollment at that
time.
@Note:Thelastdigitin000010referstothefingerprintcount.0referstothefirstfingerprint,1refersto thesecondfingerprintandsoonandsoforth.
2.1.2EnrollaPassword
4)EnterEnrollAdmin interfaceaccording to the
operationin2.1EnrollanAdministrator steps1),2),
3).Press2/3to selectEnrollPwdandthenpress
Menu.
5) Press 2/3 to select Admin Accredit, and then
select Supervisor (Super administrator) or
Admin (Administrator). Press Menu to confirm
yourselection.
6) PressMenu tocontinue.
NewEnroll000010
ESC OK(Save)
EnrollAdmin EnrollFP
EnrollPwd
AdminAccreditSupervisor
ESC OK
EnrollFPNewEnroll?
ESC OK
-
FPLockUserManualV1.0
6
7) The system by default assigns unused user IDs
from 00001 and you may also manually enter an
unuseduserID.
8) Input a password by pressing the number keys
andpressMenu toconfirmyourinput.
9)Inputthepasswordagainbypressingthenumber
keysandpressMenu toconfirmyourinput.
10) Press Menu to save the enrolled data, after
successfulpasswordenrollment,thegreenindicator
willlightupfor3seconds.Iftheenrollmentfailed,
the red indicator will light up for 3 seconds, and
prompt you to reenroll it. Once the password is
successfullyenrolled,theprocedureiscompleted.
@Note:Apasswordconsistsof6to10digits.Youcanenrollonlyonepasswordfor eachuser IDandrepeatedpasswords areforbiddenotherwise, thesystemwill
promptPasswordError.
NewEnroll
UserID 00001ESC OK
NewEnroll
NewEnroll
******
NewEnroll00001P
ESC OK(save)
-
2. Enrollment and Verification
7
2.2EnrollanOrdinaryUser
An administrator can enroll another administrator, or enroll ordinary users, with
operations asfollows:
1)PowerontheFPLockbypressingtheMenukey
toopenuptheinitialinterface.
2)PressandholdtheMenukeytoaccessthemenu.
The system will prompt for administrator
confirmation. Enter the administrator password or
match your fingerprint once. Skip to step 4) if
verificationsucceedsotherwise,proceedtostep3.
3)ThesystemdisplaysthepromptErrorPwd.on
the screen and returns to the Admin Affirm
interface for reverification. The main menu
interfaceisdisplayeduponsuccessfulverification.
OrthesystemdisplaysthepromptPleaseTryAgn
on the screen and return to the Admin Affirm
interface for reverification. The main menu
interfaceisdisplayeduponsuccessfulverification.
02: 30: 30
FPLOCK
AdminConfirm
FPLOCK
ErrorPwd.
PleaseTryAgn
-
FPLockUserManualV1.0
8
4) Press MENU to display the user management
interface.
5)Press 2/3 to select EnrollUserand thenpress
MENU.
6)Entertheuserenrollmentinterface.
After that, the enrolled administrator can perform fingerprint and password
enrollment. The rest of the operations are basically the same with those of
administratorenrollment.Fordetails,see 2.1EnrollanAdministrator.
Menu UserManageOptionsPenDriveMng
UserManage EnrollUserEnrollAdminDeleteUser
EnrollUser EnrollFPEnrollPWD
-
2. Enrollment and Verification
9
2.3BackupEnrollment
Onthe"NewEnroll?"interfaceof2.2EnrollanOrdinaryUser,ifyoupressESCto
cancel new enrollment, then the Backup Enroll interface will be displayed, as
showninthefollowingfigure:
Thebackupenrollmentoperationsarebasicallyconsistentwith thenewenrollment
operationsexceptthatBackupEnrollinsteadofNewEnrollisdisplayedonthe
topoftheinterface.
@Note:(1)Itis recommended toenrollatleasttwodifferentfingersforlongstandingusers.
(2)Ifyouwishtomodifythepasswordafterpasswordenrollmentfinished,youcan
replacetheoriginalpasswordwiththepasswordenteredin the backupenrollment.
BackupEnrollUserID 00009
ESC OK
EnrollFP
NewEnroll?ESC OK
PressESC
-
2. Enrollment and Verification
10
2.4UserVerificationandSetNOStatus
1) Press the Menu key to display the initial
interface. The fingerprint sensor is in active state.
Press your fingerwith enrolled fingerprintor enter
your password (press Menu after entering
password).
2) Thedevicewillprompt ErrorPwd andreturnto
theinitial interfaceuntilverificationsuccessful.
Or the device will prompt Please Try Agn and
return to the initial interface until verification
successful.
?Note:Youcanonlymatchfingerprintswhenthe FPLockisinnonONstate.3)YourIDnumberwillbedisplayedonthescreen
uponsuccessfulverificationandthenyouwillhear
the unlocking sound. Rotate the handle of the FP
Lockwithin4secondstoopenthedoor.
02: 30: 30
FPLOCK
Error Pwd
PleaseTryAgn
UserID:00001
-
2. Enrollment and Verification
11
?Note:WhensettingtheNOoptiontoYES(See3.1.5NormalOpenSetting),If fingerprint or password verification is unsuccessful, the system will display a
prompt Please press your finger again or Password error. The parameters
Illegal Cnt. and Illegal Alarm are set by the administrator. The system will
triggeranalarmaftertheillegaloperationsreachthespecifiedvalue.Fordetails,see
3.1.1 OperateAlarmSetting and 3.1.2 IllegalTimes.
@Note:IfthevalueoftheparameterIllegalCnt.islargerthan6becausethefingerprintverificationfailedorthepasswordwasentered6consecutive times,the
systemwillautomaticallypoweroff.
-
2. Enrollment and Verification
12
2.5DeleteUserInformation
Warning: In deleting user information process, it is strictly prohibited to
disconnectthepowersupply,toprevent thedeletionof otherdatabymistake!!!
Theoperationsare asfollows:
1)PowerontheFPLockbypressingtheMenukey
toopenuptheinitialinterface.
2) Enter the administrator password ormatch your
fingerprint once. Move to step 4) if verification
succeedsotherwise,proceedtostep3).
3)Thesystemdisplays thepromptErrorPwdon
the screen and returns to the Admin Affirm
interface for reverification. The main menu
interfaceisdisplayeduponsuccessfulverification.
OrthesystemdisplaysthepromptPleaseTry Agn
on the screen and returns to the Admin Affirm
interface for reverification. The menu interface is
displayeduponsuccessfulverification.
02:30:30
FPLOCK
AdminAffirm
FPLOCK
Error Pwd
PleaseTryAgn
-
2. Enrollment and Verification
13
4) Press Menu to enter the user management
interface.
5)Press2/3toselectDeleteUser,andthenpress
Menu.
6)Press2/3toselect thedesireddeleteIDnumber,
andthenpressMenu toconfirm.
To deletethe userfingerprint:
7)DeletethefingerprintofspecificIDnumber,and
pressMenu toconfirm.
Todeletethe userpassword:
8)Deleteuserpassword, and then pressMenu.
Menu UserManageOptionsPenDriveMng
Menu EnrollUserEnrollAdmin
DeleteUser
DeleteUser
User ID 00002ESC OK
Dele Fingerprint000020
User ID 00002ESC OK
Del Password00002P
ESC OK
-
FPLockUserManualV1.0
14
9)PressMenutoconfirmthedeletionoftheuser,.
Otherwise press 1 (ESC) to return to User
management interface.
10) After the user deletion is finished, restart the
device,andthenverify thedeleteduserto check if
theoperationis succeeded.
@Note: The Administrator (includes super administrator) can only delete anordinaryuser.IfyouneedtodeletetheadministratorID,entertheAdvOptionin
Optionsmenu,selectClradminpri,andreturntoDeleteuseroptioninuser
managementmenutodeletethisuserID.
DelUser00002
ESC OK
DelUserDelete?
ESC OK
-
3. LockFunction and Settings
15
3.LockFunctionandSettings
3.1OperationSettings
1) PressMenu key the device will power on and
enter the initial interface. Press andholdMenu to
enter the leftinterface.
2) Input the administrator password or press the
administratorsenrolled fingerprint.
3) Press 2/3 to select Options, and then press
Menu toenterthemenu.
4) Select Operate Opt, and pressMenu to enter
themenu.
TheOperateoptionsmenuincludesOperateAlarm,IllegalTimes,Lock,Verify
Mode, and NormalOpen.
02:30:30
FPLOCK
AdminAffirm
FPLOCK
MenuUserManage
OptionsPenDriveMng
Options OperateOptSystemOpt
-
FPLockUserManualV1.0
16
3.1.1OperateAlarmSetting
Thisparameter isusedtosetiftheoperationfailuretriggers thealarm.
Follow the steps 1), 2), 3), 4) in 3.1 Operation
settings, enter the operation menu and select
Operate Alarm. Press Menu to enter the
modification state, press 2/3 to select Yes/No,
aftermodificationpressMenu tosaveandquit.
3.1.2IllegalTimes
This parameter is used to set the consecutive operation failure count. An invalid
operation alarmwill be triggeredwhen the consecutive failure count exceeds this
threshold.
@Note:ThefailurecountstartstocumulatewhentheFPLockisstarted.Ifthenumber of cumulative failures exceeds this threshold, theFPLockwill trigger an
invalidoperationalarmotherwise,thefailurecountwillbeclearedaftersuccessful
unlocking.
Follow the steps 1), 2), 3), 4) in 3.1 Operation
settings, enter the operation menu and select
Illegal Times. Press Menu to enter the
modificationstate,press2/3toset thevalue(the
valuebydefaultis10,thepermitrange is399),
Operate Opt. Operate Alarm YesIllegalTimes 10Lock 5
VerifyMode 1NormalOpen Yes
Operate Opt. OperateAlarm YesIllegalTimes 10Lock 5
Operate Opt. OperateAlarm Yes
IllegalTimes 10Lock 5
-
3. LockFunction and Settings
17
aftermodification,pressMenu tosaveandquit.
If the number of cumulative failures exceeds this threshold, the FP Lock will
automaticallypoweroff.Afterthedevicerestarts theFPLockwilltriggeran invalid
operation alarm of a buzzing sound. After about 30 seconds it will power off
automatically.
3.1.3LockSetting
Thisparameterisusedtosetthedurationfromsuccessfulmatchingtounlocking.
@Note:Theunit,valueandthemaximumvalueofthisparameterarestandardconfigurations. If you need a larger value, please consult our commercial
representativesortechnicalsupportengineers.
Follow the steps 1), 2), 3), 4) in 3.1 Operation
settings, enter the operation menu and select
Lock. Press Menu to enter the modification
state, press 2/3 to set the value (the value by
default is 5, the permit range is 315), after
modification,pressMenu tosaveandquit.
3.1.4VerifyModeSetting
Follow the steps 1), 2), 3), 4) in 3.1 Operation
settings,entertheoperationmenuandselectVerify
Mode.PressMenutoenterthemodificationstate,
press2/3 to set thevalue.There are threeoptional
values0,1,and2thatrepresentdifferentmatching
modes, and the default value is 1. PressMenu to
Operate Opt. OperateAlarm YesIllegalTimes 10
Lock 5
Operate Opt. Lock 5
VerifyMode 1NormalOpen Yes
-
FPLockUserManualV1.0
18
saveandquit
VerifyMode0:Only the administrator canopen the lockby successfulmatching,
whiletheunlockingfunctionisdisabledforordinaryusers.
Verify Mode 1: This is a default matching mode. Users can open the lock by
successful matching.
VerifyMode 2: This is a dual verificationmode. The administrator can open the
lockbysuccessfulmatching,andanordinaryusercanopenthelockbypassingthe
verificationinanytwomatchingmodes.
3.1.5NormalOpenSetting
ItisusedtosetthelockalwaysinNOstate.
1) Follow the steps 1), 2), 3), 4) in3.1Operation
settings, enter the operation menu and select
Normal Open. Press Menu to enter the
modificationstate,press2/3 toselectYes/No,after
modification, andthenpressMenu tosaveandquit.
2) In the start interface verify the fingerprint (the
finger press please refer to 1.3 Fingerprint Press
Introduction)andunlock.
3)PromptifyouselectNOstate,andpressMenu to
save.
Operate Opt. Lock 5VerifyMode 1
NormalOpen Yes
02:30:30
FPLOCK
NormalOpenESC OK
-
3. LockFunction and Settings
19
4)Aftersuccessfulsetting,thescreenwill displayas
seenontheleft.Thatindicatethesettingissuccess,
andthebuzzingsoundwillbeheardthreetimesfor
prompt.
5)TodisabletheNOfunction,poweronthesystem
and pressMenu in the Normal Open interface.
Then the system closes the lock and automatically
powersoff.
NormalOpen
02: 30: 30
ESC OK
-
3. LockFunction and Settings
20
3.2LanguageSettings
1)PressMenuandthedevicewillpoweron,enter
the initial interface. Press and holdMenu to enter
theleftinterface.
2) Enter the administrator password ormatch your
fingerprint. Enter the next step after successful
verification.
3)Press2/3toselectOptions,andpressMenuto
enterthemenu.
4) Press 2/3 to select System Opt, and press
Menu toenterthemenu.
5)IntheLanguageOptionmenu,press3toselectthelanguage,andpressMenu
AdminAffirm
FPLOCK
02:30:30
FPLOCK
Menu UserManage
OptionsPenDriveMng
Options
OperateOptSystemOpt
AdvOptionSystemOpt DateTimeLanguage ENGDevNum 5
-
3. LockFunction and Settings
21
to enter the modification state. Press 2/3 to select ENG or SCH, then press
Menu toquit themodificationstate,press 1 (ESC)toenter theSave interface.
6) Press Menu to save settings, and it will take
effectafterdevicerestart.
@Note: Language selection is a nonstandard function. To use this function,pleaseconsultourcommercialrepresentativesortechnicalsupportengineers.
SystemOpt
SaveESC OK(Save)
-
3. LockFunction and Settings
22
3.3 AdvancedSettings
@Note: Only the super administrator has the right to perform advancedsettings.
1)PressMenuandthedevicewillpoweron,enter
the initial interface.Press and holdMenu to enter
the leftinterface.
2) Enter the administratorpassword ormatch your
fingerprintonce.Enterthenextstepaftersuccessful
verification.
3)Press 2/3 toselectOptions,andpressMenu.
4) Press 2/3 to select System Opt, and press
Menu.
02:30:30
FPLOCK
AdminAffirm
FPLOCK
Menu UserManage
OptionsPenDriveMng
Options
OperateOptSystemOpt
-
3. LockFunction and Settings
23
5) Select Adv Options under the System Opt
menu, and then pressMenu to enter the advanced
optioninterface.
The advanced options include Reset Options, Delete Logs, Clear All Data and
Clear Administrator Privilege. Press 2/3 to select the desired option, and then
pressMenu to enter the menu. Select the items and pressMenu to execute the
correspondingoperation.Thescreenwill returnto Advancedoptionsmenu.Ifyou
press 1 (ESC) and quit, it will return to the advanced option menu without any
operation.
ResetOptions: Thisparameterisusedtorestorethe FPLocktofactorydefaults.
Delete Logs: This parameter is used to delete all the verification records from a
memorychip.
ClearAllData:Thisparameterisusedtodeletealltheenrolledfingerprintimages,
passwordsandrecords.
ClearAdministratorPrivilege:Thisparameterisusedtochangealladministrators
intoordinaryusers.Thisfunctionshouldbeusedwithcaution.Itisrecommendedto
registeratleastonenewadministratorafter usingthisfunction.
SystemOpt DateTimeLanguage ENGDevNum 5
AdvOption
AdvOptions ResetOptsDelLogsClearAllData
ClearAdminPri
-
3. LockFunction and Settings
24
3.4BrowseSystemInformation
Userscanbrowsethesysteminformation,includingtheenrolledfingerprintcounts,
enrolled user, and device information. To browse the system information, the
operationsare asfollows.
1) PressMenu and the device power on, enter the
initial interface. Press and holdMenu to enter the
leftinterface.
2) Enter the administrator password ormatch your
fingerprint. Enter the next step after successful
verification.
3)Press2/3toselectOptions,andpressMenuto
enterthemenu.
UserCnt: ThenumberofenrolleduserswhichcanverifyandunlocktheFPLock.
FPCnt: Thenumberofenrolleduserfingerprints.
02:30:30
FPLOCK
AdminAffirm
FPLOCK
Menu UserManageOptionsPenDriveMng
SysInfo
Log 85AdminCnt 2PwdUsr 3FreeSpaceInfoDevInfo
SysInfo BrowseAttlogsUserCnt 5FPCnt 1
-
3. LockFunction and Settings
25
Log:Thenumberofverificationrecords in theFPLock.
Admin Cnt: The number of enrolled administrators with management privileges
(add user,delete user,etc.)
PwdUsr: Thenumberofusers enrolled password.
FreeSpaceInfo:Press2/3toselectFreespaceinformation,andpressMenuto
seethedetail.
Dev Info: Press 2/3 to select Device information, and pressMenu to see the
detailsasfollows:
SerialNumVendorDeviceNameAlgVersionFirmwareVer
FreeSpaceInfoFPCnt 499Log 29915SLogs 4095
Dev Info FPCnt(100) 5Log(10k) 3SLogs 4095ManuTime
-
3. LockFunction and Settings
26
3.5BrowseLogs
TheFPLocksupports theofflinebrowsingofunlockinglogs,whichfacilitatesusers
tocheckwhetherthereisanyexceptionalunlockingintime.
4)Please refer to 3.4Browse System Information
and followsteps1), 2), 3),andenter theoperation
interface.
5) Press 2/3 to select BrowseAttlogs, shown as
leftpictures.
6)Press 2/3 toselectthedesiredenrolledIDnumber,andpressMenutoconfirmthe
dateandtimeof Attlogs.
SysInfo BrowseAttlogsUserCnt 5FPCnt 1
BrowseAttlogs
UserID 00001ESC OK
21PIN 0000120090405 14: 49Back
The first digit indicates thetotalnumberofrecordsandthe last one indicatescurrentrecord.
-
3. LockFunction and Settings
27
3.6USBPenDriveManagement(Optional)
1)InsertaUSBpendriveintotheUSBport.
2) PressMenu to power on, and enter the initial
interface.
3) Press and hold Menu, input administrator
password or press your fingerprint and verify to
enterthenextstep.
4) Press 2/3 to select PenDriveMng, and press
Menu toenterthenextstep.
5)Thedevicewill prompt PenDriveMngpress
Menu toenterthemanagementinterface.
02:30:30
FPLOCK
AdminAffirm
FPLOCK
Menu UserManageOptions
PenDriveMng
PenDriveMngESC OK
USBport
-
FPLockUserManualV1.0
28
6)PressMenu toenterthe detailedmenu interface.
1.DownloadAttendanceLogs
1) Press 2/3 to select Dwn AttLog and then press
Menu.Whendownloadcompletes, thescreenonleft
isdisplayed.
2)Press 1 (ESC) toreturntotheinitialinterfaceandthenremovetheUSBpendrive.
Now the USB pen drive stores two files: X_attlog.dat (attendance logs) and
X_user.dat (Where"X"denotesthatthedeviceNo.).
@Tip:Ifthedownloadsucceeds,apromptCopyDataSucwillpopup.Ifthesystemdisplays thepromptPlugPenDrive,checkwhethertheUSBpendriveis
pluggedinproperly.
2.DownloadUserData
Userdatadownloading is similar to thedownloadingof attendance logs.Enter the
PenDriveMngmenuaccordingtotheprocedurestepsof1),2),3),4),5),6)of 3.6
USBPenDriveManagement.Press2/3toselectDwnLoadUser,thefilesuser.dat
(user information) and template.dat (fingerprint template) will be concurrently
downloadedtotheUSBpendrive.
3.UploadUserData
PenDriveMngDwnLoadLogDwnLoadUserUploadUser
CopyDataSuc
UpdFirmware
-
3. LockFunction and Settings
29
Uploading user data is similar to the downloading of attendance logs. Enter the
PenDriveMngmenuaccordingtotheprocedurestepsof1),2),3),4),5),6)of 3.6
USB PenDrive Management. Press 2/3 to select UpLoad User and then press
Menu.Thefiles user.dat(userinformation)and template.dat(fingerprinttemplate)
stored intheUSBpendrivewillbeconcurrentlyuploadedtotheFPLock.
@Tip:Whenuploadinguser information, ifauser IDalreadyexists in theFPLock,thenewuploaded informationwilloverwritetheexisting userdataotherwise,
thenewuserdatawillbe directlyadded.
4.UpgradeFirmware
YoucanselectUpdFirmwaretoupgradethefirmwareofaFPLockthroughthe
upgradefilesintheUSBpendrive.
@Note:Ifyouneedfirmwareupgradefiles,pleasecontactourtechnicalsupportengineers.Generallyit isnotrecommendedtoupgradethefirmware.
@Tip:Pleasedonotperforminvalidoperations(forexample,insertorremovetheUSB pen drive in a frequentmanner or during upload/download) on theUSB
pendrive,becauseitmayresultinsysteminstability.Itisrecommendedtokeepthe
dooropenduringtheuseoftheUSBpendrive.
-
4. Other Functions
30
4.OtherFunctions
4.1RoutineOperationIndications
Useroperationsuccessindication:
Thebuzzersoundsonce,andthegreenLEDindicatoris lightupfor3seconds.
Useroperationfailureindication:
The buzzer sounds two short tones and the red LED indicator is light up for 3
seconds.
Warningindication:
Thebuzzersounds fiveshort tonesconsecutively.
4.2AdministratorLossPrevention
Toavoidthemenuoperationfailureasaresultoflossoftheadministrator,youmay
takethefollowingmeasures:PressandholdtheMenukeyfor3secondstodisplay
the administrator verification interface.Thenmove theband switch on the rear of
the FP Lock to the left or right. Now you can access the menu as a super
administratorformanagementandoperation.
Bandswitch
-
4. Other Functions
31
4.3BatteryLowVoltageProtection
Low Voltage Protection: When the battery meter stays at one bar, the system
promptsyoutoreplacethebatteryandthebatteryiconstartsflashing.If youpress
andholdtheMenukey,thesystem will prompt youthatyoucannotaccessthemenu.
In addition, the menu is also inaccessible during use of external power so as to
preventdatalosscausedbypowerinstability.Whenthebatterymeterstayslessthan
onebar,thedeviceshutsoffautomatically.
4.4ProgramAutomaticallyExitandPoweroff
n The FP Lock powers off automatically upon successful matching and
unlocking.
n TheFPLock powers off automaticallywhen you set Yes for the Normal
Openoptionuponsuccessfulmatchingandunlocking,andsetasnormalopen
state.
n TheFPLockpowersoffautomaticallywhenthenumberofillegaloperations
exceedsthethreshold.Andafterrestart,theFPLockpowersoffautomatically
whenanalarm istriggeredfor30seconds.
n TheFPLockpowersoffautomaticallywhenthesupplyvoltageislowerthan
level3detectionvoltage.
n The FP Lock powers off automatically if there is no keystroke within 10
secondsonthe initial interface.
-
5. Appendix: TechnicalSpecifications
32
5.Appendix:TechnicalSpecifications
Screen: OLEDdisplay
Sensor: Optics sensorwithoutcoating
Capacity: 500fingerprintimages100passwords500users
Verification mode: Fingerprint, password, fingerprint plus password
matching
Recordcapacity: 30000
CommunicationMode: USB flash disk
Resolution: 500DPI
Identificationspeed: 2seconds
Falseacceptancerate: 0.0001%
Falserejectionrate: 1%
Power:FourAAbatteriesworkingvoltage:4.8V6V
Unlockingtimes: 4000(FourNANFUalkalinebatteries)
Temperature: 1055C
Humidity:10%95%.
-
5. Appendix: TechnicalSpecifications
33
Thisdocumentissubjecttochangewithoutpriornotice.
PrintedinChina