L2+ 24-Port Gigabit Managed Switch with Hardware Layer3 ... · Thank you for purchasing PLANET L2+...
Transcript of L2+ 24-Port Gigabit Managed Switch with Hardware Layer3 ... · Thank you for purchasing PLANET L2+...
L2+ 24-Port Gigabit Managed Switch with
Hardware Layer3 IPv4/IPv6 Static Routing
GS-5220-16S8C
GS-5220-16S8CR
Quick Installation Guide
Table of Contents
1. Package Contents ....................................................................................... 3
2. Requirements ............................................................................................. 4
3. Terminal Setup ........................................................................................... 5
4. Logon to Console ........................................................................................ 6
5. ConfiguringIPAddress ................................................................................ 7
6. Starting Web Management .........................................................................10
7. SavingConfiguration ..................................................................................13
8. RecoveringBacktoDefaultConfiguration .....................................................14
9. WiringDCPowerInputs .............................................................................15
10. Customer Support .....................................................................................16
3
1. Package ContentsThankyouforpurchasingPLANETL2+24-portGigabitManagedSwitchwithLayer3IPv4/IPv6StaticRouting.Thedescriptionsofthesemodelsareasfollows:
GS-5220-16S8C L2+ 24-port 100/1000X SFP Slots with 8-port Shared TPManagedSwitch
GS-5220-16S8CR L2+ 24-port 100/1000X SFP Slots with 8-port Shared TPManagedSwitch+AC/DCRedundantPower
“Managed Switch” is mentioned in this Quick Installation Guide refers to theabovefourmodels.
Open the box of the Managed Switch and carefully unpack it. The box shouldcontainthefollowingitems:
z ManagedSwitchx1
z QuickInstallationGuidex1
z RJ-45toRS232Cablex1
z RubberFeetx4
z TwoRack-mountingBracketswithAttachmentScrewsx1
z PowerCordx1
z SFPDustCapx24
If any item is found missing or damaged, please contact your local reseller forreplacement.
4
2. Requirements z Workstations running Windows XP/2003/Vista/7/8/2008, MAC OS X or later,Linux,UNIX,orotherplatformsarecompatiblewithTCP/IPprotocols.
z WorkstationsareinstalledwithEthernetNIC(NetworkInterfaceCard)
z SerialPortConnection(Terminal)
The above Workstations come with COM Port (DB9) or USB-to-RS-232converter.
The aboveWorkstations have been installed with terminal emulator, such asHyperTerminalincludedinWindowsXP/2003.
Serial cable --oneend isattached to theRS-232serialport,while theotherendtotheconsoleportoftheManagedSwitch.
z EthernetPortConnection
Networkcables--Usestandardnetwork(UTP)cableswithRJ-45connectors.
The above PC is installed with Web browser and JAVA runtime environmentplug-in.
Note
It is recommended touse InternetExplore8.0or above toaccessthe Managed Switch. If theWeb interface of the Managed Switchis not accessible, please turn off the anti-virus software or firewallandthentryitagain.
5
3. Terminal SetupTo configure the system, connect a serial cable to a COM port on a PC or notebook computer and to RJ-45 type of serial (console) port of the ManagedSwitch.
Managed Switch
Serial Port115200,8,n,1
RJ-45 to RS-232 Cable
Console
115200,N,8,1PC / Workstation with
Terminal Emulation Software
Serial Port
Figure 3-1: GS-5220-16S8C/GS-5220-16S8CR Console Connectivity
A terminal program is required tomake the software connection to the ManagedSwitch. Windows' Hyper Terminal program may be a good choice. The HyperTerminalcanbeaccessedfromtheStart menu.
1. Run terminal program on the OS.
2.When the following screen appears, make sure that the COM port should beconfiguredas:
z Baud:115200
z Databits:8
z Parity:None
z Stopbits:1
z Flowcontrol:None
Figure 3-2: Hyper Terminal COM Port Configuration
6
4. Logon to ConsoleOnce the terminal is connected to the device, power on theManaged Switch andtheterminalwilldisplay“runningtestingprocedures”.Then, the followingmessageasks to log-in user name and password. The factory default user name andpasswordareshownasfollowsandtheloginscreeninFigure4-1appears.
Username:adminPassword:admin
Figure 4-1: Managed Switch Console Login Screen
TheusercannowentercommandstomanagetheManagedSwitch.Foradetaileddescriptionofthecommands,pleaserefertothefollowingchapters.
Note
1.For security reason, please change and memorize the newpasswordafterthisfirstsetup.
2.Only accept command in lowercase letter under console inter-face.
7
5.ConfiguringIPAddressTheManagedSwitchisshippedwithdefaultIPaddressshownbelow.
IPAddress:192.168.0.100SubnetMask:255.255.255.0
TocheckthecurrentIPaddressormodifyanewIPaddressfortheSwitch,pleaseusetheproceduresasfollows:
DisplayofthecurrentIPAddress
1.Atthe“#”prompt,enter“show ip interface brief”.
2.ThescreendisplaysthecurrentIPaddressshowninFigure5-1.
Figure 5-1: IP Information Screen
8
ConfigurationoftheIPAddress
3.At the“#” prompt, enter the following commandandpress<Enter>as showninFigure5-2.
GS-5220-16S8C# configure terminalGS-5220-16S8C(config)# interface vlan 1GS-5220-16S8C(config-if-vlan)# ip address 192.168.1.100 255.255.255.0
ThepreviouscommandwouldapplythefollowingsettingsfortheManagedSwitch.
IPAddress:192.168.1.100SubnetMask:255.255.255.0
Figure 5-2: Configuring IP Address Screen
4.Repeatstep1tocheckiftheIPaddressischanged.
9
Storethecurrentswitchconfiguration
5.Atthe “#” prompt,enterthefollowingcommandandpress<Enter>.
# copy running-config startup-config
Figure 5-3: Saving Current Configuration Command Screen
If the IP is successfully configured, the Managed Switch will apply the new IPaddress setting immediately. You can access the Web interface of the ManagedSwitchthroughthenewIPaddress.
Note
If you are not familiar with the console command or the relatedparameter, enter “help” anytime in console to get the help description.
10
6. Starting Web ManagementThe following shows how to start up the Web Management of the ManagedSwitch. Note the Managed Switch is configured through an Ethernet connection.Please make sure the manager PC must be set on the same IP subnet address.
Forexample,thedefaultIPaddressoftheManagedSwitchis192.168.0.100 then themanager PC should be set at192.168.0.x (where x is a number between 1and254,except100)andthedefaultsubnetmaskis255.255.255.0.
PC / Workstationwith Web Browser
192.168.0.x
Managed Switch
RJ-45/UTP Cable
IP Address:192.168.0.100
Figure 6-1: IP Management Diagram
Logging in the Managed Switch
1.Use Internet Explorer 8.0 or above Web browser and enter IP addresshttp://192.168.0.100(thefactorydefaultIPaddressortheonethatyouhavejustchangedinconsole)toaccesstheWebinterface.
11
2.When the followingdialogboxappears,pleaseenter thedefaultusernameandpassword“admin” (or the password youhave changed via console). The loginscreeninFigure6-2appears.
DefaultIPAddress:192.168.0.100DefaultUsername:adminDefaultPassword:admin
Figure 6-2: Login Screen
3.Afterenteringthepassword,themainscreenappearsasFigure6-3shows.
Figure 6-3: Web Main Screen of Managed Switch
12
TheSwitchMenuontheleftoftheWebpageletyouaccessallthecommandsandstatisticstheManagedSwitchprovides.
Figure 6-4: Switch Menu
Note
If youarenot familiarwithSwitch functionsor the relatedparam-eter,press“Help icon” anytime on the Web page to get the help description.
Now, you can use the Web management interface to continue the Switchmanagement or manage the Switch by console interface.
Please refer to the user’s manual for more.
13
7.SavingConfigurationIn the Managed Switch, the running configuration file stores in the RAM. In thecurrentversion,therunningconfigurationsequenceofrunning-configcanbesavedfrom the RAM to FLASH by executing save startup config command, so that therunning configuration sequence becomes the startup configuration file, which iscalledconfigurationsave.
To save all applied changes and set the current configuration as a startupconfiguration. The startup-configuration file will be loaded automatically across asystem reboot.
1.ClickSystem,Save Startup Config.
2. Press the “Save Configuration” button.
14
8.RecoveringBacktoDefaultConfiguration IP address has been changed or admin password has been forgotten –To reset the IP address to the default IP address “192.168.0.100” or reset the login password to default value, press the hardware reset button on the front panel for about 10 seconds. After the device is rebooted, you can login themanagement Web interface within the same subnet of 192.168.0.xx.
Reset
PWRReset
18 20 22 242 4 6 8 10 12 14 16
17 19 21 231 3 5 7 9 11 13 15
FAN
Fault
GS-5220-16S8C LNK ACT 1000 10/100
24-Port 100/1000X SFP Managed SwitchAlert
Figure 8-2: GS-5220-16S8C Series Reset Button
15
9.WiringDCPowerInputs DC Power ConnectorThe rear panels of theGS-5220-16S8CR contain a power switch and aDC powerconnector,whichacceptsDCpowerinputvoltagefrom36Vto60VDC.ConnectthepowercabletotheManagedSwitchattheinputterminalblock.Thesizeofthetwoscrews in the terminal block is M3.5.
ON
OFF
DC POWER
DC Input Range36~60V
V+Ensure the power switchin the “OFF” position before connect the DC wire.
CAUTION
Figure 9-1: Rear Panel of GS-5220-16S8CR
Warning
Before connecting the DC power cable to the input terminal block of the GS-5220-16S8CR, ensure that the power switch is in the“OFF” positionandtheDCpowerisOFF.
Note
Thewiregaugefortheterminalblockshouldbeintherangeof12~24AWG.TheDCInputrangeisfrom36Vto60VDC.
16
10. Customer SupportThank you for purchasing PLANET products. You can browse our online FAQresourceandUser’sManualonPLANETWebsitefirsttocheckifitcouldsolveyourissue.Ifyouneedmoresupportinformation,pleasecontactPLANETswitchsupportteam.
PLANETonlineFAQ:http://www.planet.com.tw/en/support/faq.php?type=1
Switchsupportteammailaddress:[email protected]
GS-5220-16S8C/GS-5220-16S8CRUser’sManualhttp://www.planet.com.tw/en/support/download.php?type1=1&model=48563&type=3
Copyright © PLANET Technology Corp. 2014.Contents are subject to revision without prior notice.PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.