L1 01 System Overview B 03
Transcript of L1 01 System Overview B 03
-
8/10/2019 L1 01 System Overview B 03
1/31
> L1_01_System_Overview_B_031 1
Sys tem Overview
-
8/10/2019 L1 01 System Overview B 03
2/31
> L1_01_System_Overview_B_032 2
Summary
1) Recal l what is a system
2) PACiS sys tems advantages
4) PACiS Architectu res
3) PACiS Devic es and Too ls
5) PACiS Station Bus
-
8/10/2019 L1 01 System Overview B 03
3/31
> L1_01_System_Overview_B_033 3
1.1) Sys tem Defin it ion
1.2) Main System Funct io ns
1) System Defini t ion
-
8/10/2019 L1 01 System Overview B 03
4/31
> L1_01_System_Overview_B_034 4
1.1) Defin it ion
System is a set of devices with specific functions that interact
one to/with other with common rules
Fast Ethernet
UCA2- IEC 61850
I/Os
SBUS IED
SCADA
PACiS GTW
PACiS OI Client
PACiS OI ServerMaster clock
(GPS)
SCADA
MiCOM C264C
I/Os
MiCOM C264
System is COMMUNICATION & CONFIGURATION
SBUS Station BUS (system federal network UCA2...)
TBUS Tele control BUS (Remote Control Point or SCADA)
LBUS Legacy BUS (Field BUS to IED)
-
8/10/2019 L1 01 System Overview B 03
5/31
> L1_01_System_Overview_B_035 5
1.2) Main Sys tem Funct ions
HMI Station/Bay
Flow Printing Sequence Of Event, Log inArchives with reports
Alarms Manage/audible/viewer/printing
State/Event viewer/printing
Control Mode(local/remote : Bay, Substation)
Exploitation Mode(run, stand-by, maintenance)Uniqueness, InterLocK, automation running
Force - Suppress - Substitute of DP
Basic controlsequence like DE, SBO
Built-in Control (AVR, Synchro, AutoRecloser, Coil)
Group, PSL, PLC
Time management
Databases management(download, switch, version)
Test mode, SBMC
Disturbance Automatic upload/viewing
Tunnelling on IED
Supervision
Control
from
Bay
Substation
SCADA
Maintenance
-
8/10/2019 L1 01 System Overview B 03
6/31
> L1_01_System_Overview_B_036 6
2) PACiS Station BUS
2.1) SBUS Ethernet
2.2) SBUS Pro toc ol
-
8/10/2019 L1 01 System Overview B 03
7/31> L1_01_System_Overview_B_037 7
2.1) SBUS Ethernet
Link Layer Ethernet
Standard Equipment Fibre, switch, Router
Standard Layer Camera, Setting
Ethernet Standard protocol FTP, ...
Fast Communication 100 mbp/s
MiCOM Ethernet Equipment
Embedded SWU, SWR, SWD
MiCOM H34x, H35x
Embedded H14x, H15x, H16x
MiCOM H63x
=> Environmental, Supply, Redundancy
-
8/10/2019 L1 01 System Overview B 03
8/31> L1_01_System_Overview_B_038 8
Protocol: UCA2 (IEC 61850) Client/Server
Standard/Open
N Clients M Servers
Optimized traffic
Fast Communication
Protocol Standard
IED on SBUS
Use Competitors IED
Used by Competitor System
2.2) SBUS Pro toco l
-
8/10/2019 L1 01 System Overview B 03
9/31> L1_01_System_Overview_B_039 9
3) PACiS Devices and Tools
3.1) PACiS Dev ices Range
3.2) PACiS Dev ices
3.3) PACiS Too ls SBUS Ethernet
-
8/10/2019 L1 01 System Overview B 03
10/31> L1_01_System_Overview_B_0310 10
Visible
Hidden
Tools
3.1) PACiS Devices Range
PACiS Operator Interface
PACiS System Management Tool
MiCOM Cx6x Computer
MiCOM Hxyx Ethernet Switch
MiCOM GTW (Gateway)
PACiS Agency (Station BUS)
PACiS System Configuration Editor
PACiS Equipment Simulator
C364 PCI board
C264 Medium
Local, remote, Web
SWU, H14x, H34x
GI74, IEC 101,...
UCA2
IEC 61850
-
8/10/2019 L1 01 System Overview B 03
11/31> L1_01_System_Overview_B_0311 11
3.2) PACiS Devices
OI-PACiS Operator Interface
GTW- MiCOM (Gateway)
Hx4x- MiCOM Ethernet Switch
Cx64- MiCOM Cx64 Computers
-
8/10/2019 L1 01 System Overview B 03
12/31> L1_01_System_Overview_B_0312 12
3.3) PACiS Too ls
ES- PACiS Equipment Simulator
SCE- PACiS System Configuration Editor
SMT- PACiS System Management Tool
-
8/10/2019 L1 01 System Overview B 03
13/31> L1_01_System_Overview_B_0313 13
3.4) PACiS Device / Sys tem Functio n
Acquisition Wires & LBUS IED
Acquisition SBUS IEDSCADA Transmission
HMI
Flow Printing
Archives
Alarms/State/Event Display
Control Exploitation Mode
Fast GOOSE
Uniqueness, InterLocK, automation running
Force - Suppress - Substitute of DP
Basic controlDE, SBO
Built-in Control
Group, PSL, PLC
Time management
Databases management
Test mode, SBMC
Disturbance Automatic upload/viewing
Tunnelling on IED
C264
C264 OI Server GTWC264 GTW
C264 OI Client
C264 OI Server
(C264) OI Server
C264 OI Server/Client
C264 OI Server GTW
C264
C264
C264
C264
C264
C264
C264 SMT OI Server GTW
CMT SMT
C264 SMT, GTW
SMT+S1
Agency+S1
-
8/10/2019 L1 01 System Overview B 03
14/31> L1_01_System_Overview_B_0314 14
3) PACiS Architectu re Overview
4.1) Principle Sys tem A rch itectures
4.2) PC Based Arch itectu re Example
4.3) Distr ibu ted Arc hitecture Example
4.4) MiCOM Compu ter Stand -alone Example
-
8/10/2019 L1 01 System Overview B 03
15/31> L1_01_System_Overview_B_0315 15
4.1) Princip le System Arch itectu re
Local UCA2 IEDs
PACiS Operator Interface
PACiS System Management Tool
Remote OI
8 Clients
Master clock
(GPS)
Redundancy
Remote
Station
Video
MiCOM Cx6x Computer
Fast Ethernet UCA2-IEC 61850
SCADA Interface
IEC 60870-5-101, GI74, DNP3
PACiS Gateway
Protections
IED
SBUS Station BUS
TBUS Tele control BUS
LBUS
Legacy BUS
MiCOM Hx4x
-
8/10/2019 L1 01 System Overview B 03
16/31> L1_01_System_Overview_B_0316 16
4.2) PC based A rch itectu re Examp le
FUNCTIONSSeveral Display/PC Display
HMI System/Process (users)
HMI Alarm, Events, Trend
HMI Tools support (SCE, S1)
Archiving
Printer Logging SOESystem Time Synchronisation
Legacy BUS (IED)
Tele control BUS (SCADA)
IED SBUS
Time TaggingBasic Controls (DE, SBO)
PSL, PLC, Build-in controlsLegacy
Busses
SCADA
Ethernet
Network
PC Ethernet
connection
Based on MiCOM C364 Computer
-
8/10/2019 L1 01 System Overview B 03
17/31> L1_01_System_Overview_B_0317 17
4.3) Distr ibu ted A rch itectu re Example
FUNCTIONS
several OI Client display (remote)
redundant OI Server
Archiving, Logging, printing
System Time Synchronisation
Redundant Computer device
High Hardware Immunity
Acquisition CT/VT
Local Control Display
Basic Controls (DE, SBO)
PSL, PLC,Build-in controls, ATCC, Synchrocheck
Legacy BUS (IED)
Tele control BUS (SCADA)
Based on MiCOM C264 Computer
Master clock
(GPS) MiCOM Cx6x
Computers
Fast Ethernet UCA2-IEC 61850
Redundancy
Protections
IED
I/Os
Protections
IED
Gateway
-
8/10/2019 L1 01 System Overview B 03
18/31> L1_01_System_Overview_B_0318 18
4.4) MiCOM Compu ter Stand -A lone Examp le
Up to 4 Serial Links (RS 485/232) for SCADA & IED interface
IEDs Links (Master/Client):T103/T101/DNP3/MODBUS/UCA2
SCADA Links (slave/server):
T101/T104/DNP3/UCA2
GPS Clock on
IRIG-B
Integration with a new type of SCADA or IED is subject to
data model development and integration tests
-
8/10/2019 L1 01 System Overview B 03
19/31> L1_01_System_Overview_B_0319 19
5) Detai l on PACiS Station BUS
5) PACiS Station BUS
5.1) Station BUS : Definit ion
5.2) Station BUS : Overview5.3) Station BUS : Client/Server Mechan ism
5.4) Stat ion BUS : Protoco l Descr ipt ion
5.5) Station BUS : Network Devices
5.6) Station BUS : Topology
-
8/10/2019 L1 01 System Overview B 03
20/31> L1_01_System_Overview_B_0320 20
5.1) Stat ion BUS : Defin it ion
SBUSStation BUS
(federate all system devices)
Except PACiS SCE for configuration
Use a Communication Agency
Common ApplicationProgram.Interface
to all system device
-
8/10/2019 L1 01 System Overview B 03
21/31> L1_01_System_Overview_B_0321 21
5.2) Stat ion BUS : Overview
Network: Ethernet
Standard 10/100 Mbps, Copper Tx, Optic FxEMC Electric Plant
Public Hirshmann
Specific : Immunity, Power Supply=> MiCOM Hx4x
Redundancy => MiCOM Hx5x, SWR
Protocol: UCA2 (61850) Client/Server
Standard/Open
N Clients M Servers
Optimized trafficFast Communication
-
8/10/2019 L1 01 System Overview B 03
22/31> L1_01_System_Overview_B_0322 22
5.3) Stat ion BUS : Client/Server Mechanism (1)
Protocol: UCA2 (61850) Client/Server
SERVER
MiCOM C264
UCA2 IED
CLIENT
PACiS OI
Server
PACiS
Gateway
These are all
my data
I subscribe to
these data
I report the change of state of
this data you subscribed
OPTIMIZED TRAFFIC
MiCOM C264
(Gateway,
automation)
-
8/10/2019 L1 01 System Overview B 03
23/31
> L1_01_System_Overview_B_0323 23
5.3) Stat ion BUS : Client/Server Mechanism (2)
Protocol: UCA2 (61850) Client/Server
SERVER
Send Reports (RP)
Send GOOSE (fast message for
Single and Double Points)
Receive Controls
Send Control Acknowledgements
CLIENT
Receive Reports (RP)
Send Controls
Receive Control
Acknowledgements
-
8/10/2019 L1 01 System Overview B 03
24/31
> L1_01_System_Overview_B_0324 24
5.4) Stat ion BUS : Protoco l Desc ript ion
Protocol: UCA2
SERVER (IP @)
Logical Device : LD0 (mandatory : inner information)
Logical Device : 1 LD per bay
Brick : 1 per electrical device (ex : XCBR, SWIT)
Functional Components(ST for Status, CO for Control, MX for
measurements )
Data Object leaf
(SI, SIT, BO, DCO, AI )
-
8/10/2019 L1 01 System Overview B 03
25/31
> L1_01_System_Overview_B_0325 25
6) PACiS Devices Featu res
6.1) PACiS Server
6.2) PACiS Cli ents
6.3) PACiS Too ls
-
8/10/2019 L1 01 System Overview B 03
26/31
> L1_01_System_Overview_B_0326 26
6.1) PACiS Computer
Cx64- MiCOM Cx64 Computers
Wiring I/O & time tag
LBUS
Server SBUSAutomations
option TBUS printing
-
8/10/2019 L1 01 System Overview B 03
27/31
> L1_01_System_Overview_B_0327 27
6.2) PACiS Clients
OI-PACiS Operator Interface
OI Server
client SBUS
Archive
logging printing
Server OI Client
OI Client
Display
GTW- MiCOM (Gateway)
Client SBUS
TBUS
-
8/10/2019 L1 01 System Overview B 03
28/31
> L1_01_System_Overview_B_0328 28
6.3) PACiS Too ls
SCE- PACiS System Configuration Editor
SMT- PACiS System Management Tool
All Data Base handling
Generate Data Bag
Version coherency
Kernel UCA2 client
Data bag download/switch
Operative mode handling
DIAGnose
Automatic disturbance upload
-
8/10/2019 L1 01 System Overview B 03
29/31
> L1_01_System_Overview_B_0329 29
PACiS Sys tem KeyConcepts
-
8/10/2019 L1 01 System Overview B 03
30/31
> L1_01_System_Overview_B_0330 30
Networks SBUS Station BUS Client/Server protocol UCA2
TBUS Tele control BUS T101, T104, DNP3
LBUS Legacy BUS ModBus, T103
Ethernet ArchitecturesStar - Tree Copper
Ring Optical
PACiS ArchitecturesCentralised
PC based
Distributed
Computer Stand alone RTU
Key Concepts
System is Communication
Configuration
PACiS Devices
PACiS OI, PACiS SMT
MiCOM Cx6x, MiCOM Hxxx, PACiS Gateway
UCA2 Agency, PACiS SCE, PACiS ES
-
8/10/2019 L1 01 System Overview B 03
31/31