kyPowerful tank cleaning for small barrels and drumsAlfa Laval GJ 7
.
ApplicationThe smallest rotary impingement tank cleaning device, the Alfa LavalGJ 7 easily fits through a 3.8 cm (1.5”) access hole. Capable ofoperating at both high and low pressures, this device delivers 2.27 kg(5 lbs.) of cleaning force at .76 m (2.5 ft.) The Alfa Laval GJ 7 offersquick and easy cleaning of barrels, drums, and other small vessels in awide variety of industries. The device is part of the world-renownedGamajet range of high impact tank cleaning devices.
Working principleThe Gamajet range of high impact tank cleaning devices combinepressure and flow to create high impact cleaning jets. Cleaning occursat the point at which the concentrated stream impacts the surface. Itis this impact and the tangential force that radiates from that pointwhich blasts contaminants from the surface, scouring the tank interior.In conjunction with this impact, the device is engineered to rotate ina precise, repeatable and reliable, 360° pattern. This full-coverage,global indexing pattern ensures the entire tank interior is cleaned,every time.
TECHNICAL DATA
Lubricant . . . . . . . . . . . . . . . . . . . Food gradeMax. throw length . . . . . . . . . . . . . 2 - 2.5 m (7 - 8 ft.)
PressureWorking pressure . . . . . . . . . . . . . . 3.5 - 83 bar (50-1,200 PSI)Recommended pressure . . . . . . . . . 5.5 - 55 bar (80 - 800 PSI)
Cleaning Pattern
First Cycle Full Pattern
The above drawings show the cleaning pattern achieved on acylindrical horizontal vessel. The difference between the first cycle andthe full pattern represents the number of additional cycles available toincrease the density of the cleaning.
Certificate2.1 material certificate
PHYSICAL DATA
Materials1.4404 (316L), PTFE, EPDM (FKM and FFKM available)
TemperatureMax. working temperature . . . . . . . . 95°C (203°F)Max. ambient temperature . . . . . . . . 140°C (284°F)
Weight . . . . . . . . . . . . . . . . . . . . . 6.8 kg (1.5 lbs.)
ConnectionsStandard thread . . . . . . . . . . . . . . . ½” NPT, ½” BSP
OptionsElectronic rotation sensor to verify 3D coverage.
CautionDo not use for gas evacuation or air dispersion.
Disclaimer: Information in this product data leaflet is intended for general guidance purposes. Specific data for device selection and sizing is
available upon request.
Flow Rate Impact Throw Length
0 5 10 15 20 25 30 35 40 45 50 55
0.45
0.55
0.65
0.75
0.85
0.95
1.05
1.15
1.25
1.35
2
2.25
2.5
2.75
3
3.25
3.5
3.75
4
4.25
4.5
4.75
5
5.25
5.5
5.75
6
0 100 200 300 400 500 600 700 800 psi
m3/h USgpm
bar
2-Nozzle: 2.03mm(.080")Stator: 5H
2-Nozzle: 1.9mm(.075")Stator: 4H
2-Nozzle: 1.78mm(.070")Stator: 4X
2-Nozzle: 1.78mm(.070") Stator: 4
0 5 10 15 20 25 30 35 40 45 50 55
25.4
50.4
75.4
100.4
125.4
150.4
175.4
200.4
225.4
250.4
275.4
300.4
10
20
30
40
50
60
70
80
90
100
110
120
0 100 200 300 400 500 600 700 800 psi
cm. in.
bar
3-Nozzle: 2.54mm(.100")2-Nozzle:1.78mm(.070")Stator: 4X
2-Nozzle: 2.54mm(.100")
2-Nozzle:1.78mm(.070")Stator: 4
Inlet pressure Inlet pressure- - - Wetting, — Impact cleaning
Cleaning Time .100 NOZ Cleaning Time .7-.8 NOZ
0.34 0.44 0.54 0.64 0.74 0.84
4
5
6
7
8
9
10 2.5
3
3.5
4
4.5
5
5.5
6
6.5
7
1.5 2 2.5 3 3.5 4
rpm min
m3/h
24
20
10
12
15
MVSV
USgpm
Stator
Nozzle2.54mm(.100")
2.54mm(.100")
0.45 0.55 0.65 0.75 0.85 0.95 1.05 1.15 1.25
4
5
6
7
8
9
10 3
3.25
3.5
3.75
4
4.25
4.5
4.75
5
5.25
5.5
5.75
6
2 2.5 3 3.5 4 4.5 5 5.5 USgpm
rpm min
m3/h
20
16
12
10
15
1.78mm(.070")
Stator
Nozzle
5H4H4X4
1.90mm(.075")
2.03mm(.085")
Standard DesignThe choice of nozzle diameters can optimize jet impact length and flow rate at the desired pressure. As standard documentation, the Alfa Laval GJ 7can be supplied with a “Declaration of Conformity” for material specifications.
TRAX simulation toolTRAX is a unique software that simulates how the Alfa Laval GJ 7 performs in a specific tank or vessel. The simulation gives information on wettingintensity, pattern mesh width and cleaning jet velocity. This information is used to determine the best location of the tank cleaning device and the correctcombination of flow, time, and pressure to implement.A TRAX demo containing different cleaning simulations covering a variety of applications can be used as a reference and documentation for tankcleaning applications. The TRAX demo is free and available upon request.
.
Wetting Intensity
2.5
2.9
3.4
3.9
4.5
5.3
6.1
7.1
8.3
9.6
11
13
15
0.06
0.07
0.08
0.09
0.11
0.13
0.15
0.17
0.20
0.24
0.27
0.32
0.37
TD 523-208
(USgallon/ft2)
D1.8m(70”), H2.8m(110”), 2xØ2.03mm(2xØ2/25”) Time =
1.56 min.
D1.8m(70”), H2.8m(110”), 2xØ2.03mm(2xØ2/25”) Time =
6.25 min.
.
ESE03005EN 1015
Alfa Laval reserves the right to change specifications without prior
notification. ALFA LAVAL is a trademark registered and owned by Alfa Laval
Corporate AB. © Alfa Laval
How to contact Alfa LavalContact details for all countriesare continually updated on our website.Please visit www.alfalaval.com toaccess the information direct.