KUHLMAN HALL PHASE III - Xavier University · kuhlman hall renovation phase iii xavier university...
Transcript of KUHLMAN HALL PHASE III - Xavier University · kuhlman hall renovation phase iii xavier university...
G001
COVER
SHEET
JKF REB
APRIL 17, 2015
--
-
--
-
--
-
--
-
--
-
--
-
--
-
OFFICE OF PHYSICAL PLANT
XAVIER UNIVERSITY
3800 VICTORY PARKWAY
CINCINNATI, OH 45207
513-745-2037
DATE
SHEET NO.
DA
TE
RE
VIS
IO
NIS
SU
E
DRAWN BY: CHECKED BY:
PROJECT NUMBER
KU
HL
MA
N H
AL
L R
EN
OV
AT
IO
N
PH
AS
E III
XA
VIE
R U
NIV
ER
SIT
Y
3824 LE
DG
EW
OO
D D
RIV
E
CIN
CIN
NA
TI, O
HIO
45207
4/17/2015 10:48 A
MR
:\P
LA
NT
\D
ES
IG
N P
RO
JE
CT
S\K
UH
LM
AN
H
ALL\K
UH
LM
AN
2015 P
HA
SE
III - R
EV
IS
ED
\S
HE
ET
S\G
001 C
OV
ER
S
HE
ET
.D
WG
EXPIRATION DATE: 12/31/2015
RACHEL E. BIESIK, LICENSE #11710
911723
KUHLMAN HALL
RENOVATION
PHASE III
XAVIER UNIVERSITY
3824 LEDGEWOOD DRIVE
CINCINNATI, OHIO 45207
XAVIER UNIVERSITY CAMPUS
CINCINNATI, OH
75
71
75
75
75
71
71
71
71
75
74
126
126
126
562
126
42
22
22
22
42
42
50
50
50
50
50
42
27
27
27
27
27
127
127
127
27
CINCINNATI
471
N
O
R
W
O
O
D
L
A
T
E
R
A
L
R
O
N
A
L
D
R
E
A
G
A
N
H
IG
H
W
A
Y
R
O
N
A
L
D
R
E
A
G
A
N
H
IG
H
W
A
Y
XAVIER UNIVERSITY
SITE LOCATION
SHEET INDEX
SHEET NO SHEET TITLE
G001 COVER SHEET
LS100 LIFE SAFETY PLANS
LS101 LIFE SAFETY PLANS
A100 NEW GROUND FLOOR
A107 ROOF AND ELEVATOR MACHINE ROOM PLAN
HD107 H.V.A.C. - DEMOLITION - ROOF
HV107 H.V.A.C. - NEW DUCTWORK - ROOF
HV500 H.V.A.C. - COMCHECK
E000 ELECTRIC LEGEND
ED100 ELECTRIC DEMOLITION - GROUND FLOOR
ED107 ELECTRIC DEMOLITION - ROOF
E100 ELECTRIC - GROUND FLOOR
E107 ELECTRIC - ROOF
E201 ELECTRICAL SCHEDULES
E300 ELECTRICAL SINGLE-LINE DIAGRAM
PROJECT SUMMARY
KUHLMAN HALL IS A 7-STORY BRICK, CMU, AND CONCRETE STRUCTURE
CONSTRUCTED IN 1966. KUHLMAN HALL IS CONNECTED TO HUSMAN
HALL, BUILT 1964, AND SEPARATED BY A 12'-0" WIDE BREEZEWAY.
HUSMAN HALL MECHANICAL AND ELECTRICAL SYSTEMS ARE FED
THROUGH KUHLMAN HALL.
SCOPE OF THIS PROJECT:
1. WORK ASSOCIATED WITH ELEVATOR MODERNIZATION
1
1/16" = 1'-0"
GROUND FLOOR LIFE SAFETY PLAN
FEC
FEC
FEC
FE
INCIDENTAL
OCCUPANCY AREA
IS SPRINKLERED
ELEVATOR
LOBBY -
PART OF
EXIT
ACCESS
ACCESSIBLE ENTRANCE
(1 OF 2 MAIN ENTRANCES)
INCIDENTAL
OCCUPANCY AREA
IS SPRINKLERED
2
1/16" = 1'-0"
FIRST FLOOR LIFE SAFETY PLAN
FEC
FEC
FEC
FEC
ELEVATOR
LOBBY
3
1/16" = 1'-0"
SECOND FLOOR LIFE SAFETY PLAN
FE
FEC
FEC
FEC
EXISTING
CHAPEL
OCCUPANT
LOAD=
24 SEATS
ELEVATOR
LOBBY
1 HR FIRE-RATED PARTITION
2 HR FIRE RATED BARRIER
2 HR FIRE-RATED
VERTICAL SHAFTS
NOTE: ALL RATED WALLS AND SHAFTS ARE INDICATED ON
PLANS. THESE WALLS ARE NOT BEING UPGRADED.
ANY NEW WORK DONE TO THESE PARTITIONS SHALL
BE RATED ACCORDINGLY.
EXIT SIGN (EXISTING)
FE - FIRE EXTINGUISHER (EXISTING)
FEC - FIRE EXTINGUISHER CABINET (EXISTING)
EXISTING CONDITIONS
USE GROUP = R-2
CONSTRUCTION TYPE = 1B (NON-COMBUSTIBLE.)
STORIES = 7
FIRE PROTECTION SYSTEMS
AUTOMATIC SPRINKLER SYSTEM: BUILDING IS PARTIALLY
SPRINKLERED, NO CHANGE
AUTOMATIC FIRE ALARM SYSTEM: INSTALLED THROUGHOUT.
EXISTING BUILDING CONSTRUCTION = REINFORCED 12”X12”
CONCRETE COLUMNS AND 6” TWO WAY REINFORCED CONCRETE
SLABS.
FIRE RATING OF EXISTING FLOORS: 2 HOURS MINIMUM.
FIRE RATING OF EXISTING PARTITIONS: SEE LIFE SAFETY
DRAWINGS.
ACTUAL BUILDING FOOTPRINT OF HUSMAN HALL 13, 150 SF
BUILDING FOOTPRINT OF KUHLMAN HALL ADDITION 12, 656 SF
TOTAL 25, 807 SF
ALLOWABLE AREA = UL UNLIMITED
OCCUPANT LOAD
GROUND = 11,969 SF (TOTAL)
MINUS 1,040 SF (ACCESSORY STORAGE) 4
MINUS 914 SF (MECH. EQUIP. ROOM) 3
MINUS 1,123 SF (ASSEMBLY) 75
8,892 SF (REMAINDER) 178
TOTAL 260
1ST = 12,656 SF (TOTAL)
MINUS 840 SF (RESIDENTIAL) 5
11,816 SF (REMAINDER) 236
TOTAL 241
2ND = 12,430 SF (TOTAL)
MINUS 720 SF (RESIDENTIAL) 4
MINUS 560 SF (CHAPEL) 24
11,150 SF (REMAINDER) 223
TOTAL 251
3RD = 11,387 228
4TH= 11,387 228
5TH= 11,387 228
6TH= 11,387 228
FINISH REQUIREMENTS
INTERIOR WALL AND CEILING
EXIT ENCLOSURES & EXIT PASSAGEWAYS CLASS B
CORRIDORS CLASS B
ROOMS & ENCLOSED SPACES CLASS C
LS100
LIFE
SAFETY
PLANS
JKF REB
APRIL 17, 2015
--
-
--
-
--
-
--
-
--
-
--
-
--
-
OFFICE OF PHYSICAL PLANT
XAVIER UNIVERSITY
3800 VICTORY PARKWAY
CINCINNATI, OH 45207
513-745-2037
DATE
SHEET NO.
DA
TE
RE
VIS
IO
NIS
SU
E
DRAWN BY: CHECKED BY:
PROJECT NUMBER
KU
HL
MA
N H
AL
L R
EN
OV
AT
IO
N
PH
AS
E III
XA
VIE
R U
NIV
ER
SIT
Y
3824 LE
DG
EW
OO
D D
RIV
E
CIN
CIN
NA
TI, O
HIO
45207
4/17/2015 10:48 A
MR
:\P
LA
NT
\D
ES
IG
N P
RO
JE
CT
S\K
UH
LM
AN
H
ALL\K
UH
LM
AN
2015 P
HA
SE
III - R
EV
IS
ED
\S
HE
ET
S\LS
100 LIF
E S
AF
ET
Y P
LA
NS
.D
WG
EXPIRATION DATE: 12/31/2015
RACHEL E. BIESIK, LICENSE #11710
911723
2
1/16" = 1'-0"
FOURTH FLOOR LIFE SAFETY PLAN
FEC
FEC
FE
ELEVATOR
LOBBY
1
1/16" = 1'-0"
THIRD FLOOR LIFE SAFETY PLAN
FEC
FEC
FEC
ELEVATOR
LOBBY
S
3
1/16" = 1'-0"
FIFTH FLOOR LIFE SAFETY PLAN
FEC
FEC
FEC
ELEVATOR
LOBBY
S
4
1/16" = 1'-0"
SIXTH FLOOR LIFE SAFETY PLAN
FEC
FEC
FEC
ELEVATOR
LOBBY
1 HR FIRE-RATED PARTITION
2 HR FIRE RATED BARRIER
2 HR FIRE-RATED
VERTICAL SHAFTS
NOTE: ALL RATED WALLS AND SHAFTS ARE INDICATED ON
PLANS. THESE WALLS ARE NOT BEING UPGRADED.
ANY NEW WORK DONE TO THESE PARTITIONS SHALL
BE RATED ACCORDINGLY.
EXIT SIGN (EXISTING)
FE - FIRE EXTINGUISHER (EXISTING)
FEC - FIRE EXTINGUISHER CABINET (EXISTING)
EXISTING CONDITIONS
USE GROUP = R-2
CONSTRUCTION TYPE = 1B (NON-COMBUSTIBLE.)
STORIES = 7
FIRE PROTECTION SYSTEMS
AUTOMATIC SPRINKLER SYSTEM: BUILDING IS PARTIALLY
SPRINKLERED, NO CHANGE
AUTOMATIC FIRE ALARM SYSTEM: INSTALLED THROUGHOUT.
EXISTING BUILDING CONSTRUCTION = REINFORCED 12”X12”
CONCRETE COLUMNS AND 6” TWO WAY REINFORCED CONCRETE
SLABS.
FIRE RATING OF EXISTING FLOORS: 2 HOURS MINIMUM.
FIRE RATING OF EXISTING PARTITIONS: SEE LIFE SAFETY
DRAWINGS.
ACTUAL BUILDING FOOTPRINT OF HUSMAN HALL 13, 150 SF
BUILDING FOOTPRINT OF KUHLMAN HALL ADDITION 12, 656 SF
TOTAL 25, 807 SF
ALLOWABLE AREA = UL UNLIMITED
OCCUPANT LOAD
GROUND = 11,969 SF (TOTAL)
MINUS 1,040 SF (ACCESSORY STORAGE) 4
MINUS 914 SF (MECH. EQUIP. ROOM) 3
MINUS 1,123 SF (ASSEMBLY) 75
8,892 SF (REMAINDER) 178
TOTAL 260
1ST = 12,656 SF (TOTAL)
MINUS 840 SF (RESIDENTIAL) 5
11,816 SF (REMAINDER) 236
TOTAL 241
2ND = 12,430 SF (TOTAL)
MINUS 720 SF (RESIDENTIAL) 4
MINUS 560 SF (CHAPEL) 24
11,150 SF (REMAINDER) 223
TOTAL 251
3RD = 11,387 228
4TH= 11,387 228
5TH= 11,387 228
6TH= 11,387 228
FINISH REQUIREMENTS
INTERIOR WALL AND CEILING
EXIT ENCLOSURES & EXIT PASSAGEWAYS CLASS B
CORRIDORS CLASS B
ROOMS & ENCLOSED SPACES CLASS C
S
FE
5
1/16" = 1'-0"
PENTHOUSE LIFE SAFETY PLAN
LS101
LIFE
SAFETY
PLANS
JKF REB
APRIL 17, 2015
--
-
--
-
--
-
--
-
--
-
--
-
--
-
OFFICE OF PHYSICAL PLANT
XAVIER UNIVERSITY
3800 VICTORY PARKWAY
CINCINNATI, OH 45207
513-745-2037
DATE
SHEET NO.
DA
TE
RE
VIS
IO
NIS
SU
E
DRAWN BY: CHECKED BY:
PROJECT NUMBER
KU
HL
MA
N H
AL
L R
EN
OV
AT
IO
N
PH
AS
E III
XA
VIE
R U
NIV
ER
SIT
Y
3824 LE
DG
EW
OO
D D
RIV
E
CIN
CIN
NA
TI, O
HIO
45207
4/17/2015 10:48 A
MR
:\P
LA
NT
\D
ES
IG
N P
RO
JE
CT
S\K
UH
LM
AN
H
ALL\K
UH
LM
AN
2015 P
HA
SE
III - R
EV
IS
ED
\S
HE
ET
S\LS
101 LIF
E S
AF
ET
Y P
LA
NS
.D
WG
EXPIRATION DATE: 12/31/2015
RACHEL E. BIESIK, LICENSE #11710
911723
NEW FLOOR PLAN GENERAL NOTES
A. MECHANICAL AND ELECTRICAL FIXTURES SHOWN ON
ARCHITECTURAL DRAWINGS FOR REFERENCE ONLY.
REFER TO MECHANICAL AND ELECTRICAL DRAWINGS
FOR NEW AND EXISTING FIXTURE LOCATIONS AND
QUANTITIES.
NEW FLOOR PLAN KEYNOTES
1. PROVIDE NEW PORCELAIN TILE ON FLOOR OF EXISTING
ELEVATOR CABS. SEE SPECIFICATIONS. PROVIDE SHOP
DRAWING AND SAMPLE OF FINISH FOR ACCESS PLATE.
2. SCOPE OF ELEVATOR MODERNIZATION.
3. SEE ELEVATION 2/A100 FOR INFORMATION ABOUT NEW
HOISTWAY JAMB SIGNAGE.
4. PROVIDE REQUIRED RATED WALL INFILL PATCH,
MATCHING EXISTING WALL CONSTRUCTION WITH
PLASTER FINISH, AT EACH NEW ELEVATOR LOBBY HALL
STATION (FLOORS G-6) TO INFILL PRIOR INSTALLATIONS
OF HALL STATION PANELS. COORDINATE EXTENT AND
HEIGHT OF INFILL WITH ELEVATOR MANUFACTURER
INSTALLER.
5. REMOVE ALL EXISTING SIGNAGE. PLASTER AND PAINT
WHERE SIGNS AND FASTENERS WERE REMOVED,
MATCHING EXISTING FINISH AND COLOR. PROVIDE AND
INSTALL NEW "IN CASE OF FIRE USE STAIRS SIGN"
CENTERED BETWEEN DOORS AS SHOWN ON ELEVATION
7/A100. PROVIDE SUBMITTAL TO ARCHITECT FOR SIGN
VERIFICATION. INSTALL DIGITAL PRINT EVACUATION
SIGN INSIDE CLEAR ACRYLIC HOLDER AS SHOWN ON
ELEVATION 7/A100.
5'-0
"
1
2
3/4" = 1'-0"
HOISTWAY SIGNAGE
HOISTWAY SIGNAGE GENERAL NOTE
A. FLOOR DESIGNATION SHALL BE
ON BOTH JAMBS OF THE
ELEVATOR HOISTWAY ENTRANCE.
B. FLOOR DESIGNATIONS SHALL BE
PROVIDED IN BOTH TACTILE
CHARACTERS AND BRAILLE.
C. TACTILE CHARACTERS SHALL BE 2
INCHES (51 MM) HIGH MINIMUM.
D. A TACTILE STAR SHALL BE
PROVIDED ON BOTH JAMBS AT
THE MAIN ENTRY LEVEL (GROUND
LEVEL).
NEW HOISTWAY SIGNAGE ON INSIDE OF
ELEVATOR DOOR JAMB (BY OTHERS)
NEW REMOVABLE
CAST STAINLESS STEEL
ACCESS PLATE
NEW PORCELAIN TILE.
5/16" THICK W/ 3/16"
SETTING BED
NEW 5" DIAMETER x 1/16
" THICK STEEL PLATE
NEW ST ST NUT W/ SELF LOCKING
WASHER
EXISTING ACCESS
PLATE AND RECEIVER
TRIM TO REMAIN.
DRILL HOLE AS
NEEDED.
EXISTING STEEL CAB
FLOOR
NEW INTEGRAL CONCEALED
ST ST STUD
3
1
4
"
EXISTING ACCESS HOLE TO
REMAIN
NEW ST ST RECEIVER
TRIM. FASTEN TO
EXISTING PLYWOOD W/
COUNTERSUNK
FLATHEAD ST ST
SCREWS
SATIN FINISH
TEXTURED FINISH . PROVIDE
SAMPLES. SURFACE @ -1/16 "
2
3
4
"
1"
9"
NEW ST ST RECEIVER TRIM
NEW WATERPROOF
MEMBRANE
SATIN FINISH
1
2
"
SATIN FINISH
7"
NEW ST ST ACCES PLATE
1 2
"
NEW 1/4"
UNDERLAYMENT
CEMENT BOARD.
EXISTING WOOD
UNDERLAYMENT TO
REMAIN - IF SOLID.
SILICONE SEALANT
1/2" BACKER ROD
PORCELAIN TILE
ON SETTING BED
ST ST WALL BASE
BY ELEVATOR MFR
CEMENT BOARD
3 4
"
PERIMETER MOVEMENT JOINT DETAIL /
NEW TILE FLOOR FINISH OF ELEVATOR CAB
5
6"-1'-0"
NEW ACCESS PLATE / PLAN VIEW
4
6"-1'-0"
NEW ACCESS PLATE SECTION
6
6"-1'-0"
PERIMETER MOVEMENT JOINT
3 /16" WIDE GROUT
JOINT TYPICAL
3
1/4"=1'-0"
TYPICAL ELEVATOR FLOOR FINISH PLAN
NEW SCHLUTER
SCHIENE E125EB
NEW ACCESS PANEL. SEE
DTL 5/A100
PROVIDE 1/2" WIDE
MOVEMENT JOINT AT
PERIMETER . SEE DTL 6/A100
NEW PORCELAIN TILE, CEMENT
BOARD, AND WATERPROOF
MEMBRANE. SEE SPEC AND
DETAILS THIS SHEET.
4'-1"
6'-7"
4'-1"
6'-7"
REMOVE EXISTING ADJACENT
6” WIDE REDUCING
THRESHOLD AND PARTIAL
TILES. PATCH LOBBY FLOOR
TILE W/ LARGER PIECE TILES
IN
3
16
" MORTAR BED AND
PROVIDE SCHLUTER SCHIENE
E 125EB EDGE FLUSH W/ NEW
RAISED SILL. TYPICAL AT BOTH
DOORS ON ALL (7) LEVELS.
1
1
MA
TC
H
1
1/8" = 1'-0"
GROUND FLOOR PLAN
2
3
3
1
1
A100
3
4 5
MA
TC
H
7
1/2" = 1'-0"
LOBBY SIGNAGE
6'-0
"
DIGITAL PRINT
EVACUATION
SIGN INSIDE
CLEAR ACRYLIC
PLAN HOLDER,
11"X17"
"IN CASE OF
FIRE USE
STAIRS" SIGN,
6" X 7"
EQ EQ
3'-8
"
5'-2
"
A100
NEW
GROUND
FLOOR
JKF REB
APRIL 17, 2015
--
-
--
-
--
-
--
-
--
-
--
-
OFFICE OF PHYSICAL PLANT
XAVIER UNIVERSITY
3800 VICTORY PARKWAY
CINCINNATI, OH 45207
513-745-2037
DATE
SHEET NO.
DA
TE
RE
VIS
IO
NIS
SU
E
DRAWN BY: CHECKED BY:
PROJECT NUMBER
KU
HL
MA
N H
AL
L R
EN
OV
AT
IO
N
PH
AS
E III
XA
VIE
R U
NIV
ER
SIT
Y
3824 LE
DG
EW
OO
D D
RIV
E
CIN
CIN
NA
TI, O
HIO
45207
4/17/2015 10:48 A
MR
:\P
LA
NT
\D
ES
IG
N P
RO
JE
CT
S\K
UH
LM
AN
H
ALL\K
UH
LM
AN
2015 P
HA
SE
III - R
EV
IS
ED
\S
HE
ET
S\A
100 N
EW
G
RO
UN
D F
LO
OR
.D
WG
EXPIRATION DATE: 12/31/2015
RACHEL E. BIESIK, LICENSE #11710
911723
--
-
A107
ROOF AND
ELEVATOR
MACHINE
ROOM PLAN
JKF REB
APRIL 17, 2015
--
-
--
-
--
-
--
-
--
-
--
-
--
-
OFFICE OF PHYSICAL PLANT
XAVIER UNIVERSITY
3800 VICTORY PARKWAY
CINCINNATI, OH 45207
513-745-2037
DATE
SHEET NO.
DA
TE
RE
VIS
IO
NIS
SU
E
DRAWN BY: CHECKED BY:
PROJECT NUMBER
KU
HL
MA
N H
AL
L R
EN
OV
AT
IO
N
PH
AS
E III
XA
VIE
R U
NIV
ER
SIT
Y
3824 LE
DG
EW
OO
D D
RIV
E
CIN
CIN
NA
TI, O
HIO
45207
4/17/2015 10:48 A
MR
:\P
LA
NT
\D
ES
IG
N P
RO
JE
CT
S\K
UH
LM
AN
H
ALL\K
UH
LM
AN
2015 P
HA
SE
III - R
EV
IS
ED
\S
HE
ET
S\A
107 R
OO
F A
ND
E
LE
VA
TO
R M
AC
HIN
E R
OO
M P
LA
N.D
WG
EXPIRATION DATE: 12/31/2015
RACHEL E. BIESIK, LICENSE #11710
911723
NEW FLOOR PLAN GENERAL NOTES
A. MECHANICAL AND ELECTRICAL FIXTURES SHOWN ON
ARCHITECTURAL DRAWINGS FOR REFERENCE ONLY.
REFER TO MECHANICAL AND ELECTRICAL DRAWINGS
FOR NEW AND EXISTING FIXTURE LOCATIONS AND
QUANTITIES.
B. COORDINATE ALL WORK WITH MECHANICAL AND
ELECTRICAL DRAWINGS.
C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR
SPECIFIC INFORMATION ON PRODUCTS USED.
D. IF CONTRACTOR SHOULD DISCOVER ANY UNFORESEEN
PROBLEMS DURING THE REMOVAL OF ANY EXISTING
CONSTRUCTION OR THE CONSTRUCTION OF ANY NEW
WORK, THE ARCHITECT SHOULD BE NOTIFIED
IMMEDIATELY AND THAT PARTICULAR WORK SHOULD BE
DISCONTINUED UNTIL NECESSARY REVISIONS CAN BE
DECIDED UPON.
E. ALL CMU INFILL TO BE NOM. 4X8X16 IN SIZE. ALL FACE
BRICK INFILL TO NOM. 4X2-
1
2
X8. FILL COLLAR JOINT WITH
GROUT. SEE SPECIFICATIONS.
NEW FLOOR PLAN KEYNOTES
1. SCOPE OF ELEVATOR MODERNIZATION.
2. REMOVE THRU-WALL A/C UNIT WOOD FRAMING AND
PANEL, METAL THRU-WALL FRAME, AND ANY OTHER
INFILL PANELS. REMOVE PRIOR INFILL BRICK (12
BRICKS). PATCH OPENING (NOM. 1'-4"H X 3'-8"W) WITH
NOM. 4" CMU INSIDE AND NOM. 4" FACE BRICK ON THE
EXTERIOR. SEE GENERAL NOTE E.
3. REMOVE METAL THRU-WALL FRAME, BLANK-OFF PANELS
AND EXTERIOR LOUVER. PATCH OPENING (NOM. 1'-4"H X
3'-8"W) WITH NOM. 4" CMU INSIDE AND NOM. 4" FACE
BRICK ON THE EXTERIOR. SEE GENERAL NOTE E.
4. PATCH OPENING OF DEMO'D THRU-WALL EXHAUST UNIT
(NOM. 1'-4"H X 1'-4"W) WITH NOM. 4" CMU INSIDE AND
NOM. 4" FACE BRICK ON THE EXTERIOR. SEE GENERAL
NOTE E.
5. PREP AND PAINT EXTERIOR LOUVERS COLOR P-1.
6. PREP AND PAINT THE OUTSIDE ONLY OF THE EXTERIOR
DOOR COLOR P-1.
7. PACK ALL GAPS/HOLES AT FLOOR PENETRATIONS WITH
MINERAL WOOL. SEAL TOP OF MINERAL WOOL WITH
FIRE-RATED CAULK PER FIRESTOPPING
MANUFACTURER'S INSTRUCTIONS. REFER TO UL
DESIGN SYSTEM NO. C-AJ-1226. SEE FIRESTOPPING
SPECIFICATIONS.
NEW PAINTING SCHEDULE
P-1 MATCH EXISTING ELEVATOR MACHINE ROOM EXTERIOR
DOOR FRAME
(EXTERIOR DOOR AND LOUVERS)
MA
TC
H
1
1/8" = 1'-0"
NEW ROOF AND ELEVATOR MACHINE ROOM PLAN
1
A107
2
MA
TC
H
2
1/4" = 1'-0"
NEW ENLARGED ELEVATOR MACHINE ROOM PLAN
2
3
5
7
4
6
7
7