G001 COVER SHEET JKF REB APRIL 17, 2015 - - - - - - - - - - - - - - - - - - - - - OFFICE OF PHYSICAL PLANT XAVIER UNIVERSITY 3800 VICTORY PARKWAY CINCINNATI, OH 45207 513-745-2037 DATE SHEET NO. DATE REVISION ISSUE DRAWN BY: CHECKED BY: PROJECT NUMBER KUHLMAN HALL RENOVATION PHASE III XAVIER UNIVERSITY 3824 LEDGEWOOD DRIVE CINCINNATI, OHIO 45207 4/17/2015 10:48 AM R:\PLANT\DESIGN PROJECTS\KUHLMAN HALL\KUHLMAN 2015 PHASE III - REVISED\SHEETS\G001 COVER SHEET.DWG EXPIRATION DATE: 12/31/2015 RACHEL E. BIESIK, LICENSE #11710 911723 KUHLMAN HALL RENOVATION PHASE III XAVIER UNIVERSITY 3824 LEDGEWOOD DRIVE CINCINNATI, OHIO 45207 XAVIER UNIVERSITY CAMPUS CINCINNATI, OH 75 71 75 75 75 71 71 71 71 75 74 126 126 126 562 126 42 22 22 22 42 42 50 50 50 50 50 42 27 27 27 27 27 127 127 127 27 CINCINNATI 471 NORWOOD LATERAL RONALD REAGAN HIGHWAY RONALD REAGAN HIGHWAY XAVIER UNIVERSITY SITE LOCATION SHEET INDEX SHEET NO SHEET TITLE G001 COVER SHEET LS100 LIFE SAFETY PLANS LS101 LIFE SAFETY PLANS A100 NEW GROUND FLOOR A107 ROOF AND ELEVATOR MACHINE ROOM PLAN HD107 H.V.A.C. - DEMOLITION - ROOF HV107 H.V.A.C. - NEW DUCTWORK - ROOF HV500 H.V.A.C. - COMCHECK E000 ELECTRIC LEGEND ED100 ELECTRIC DEMOLITION - GROUND FLOOR ED107 ELECTRIC DEMOLITION - ROOF E100 ELECTRIC - GROUND FLOOR E107 ELECTRIC - ROOF E201 ELECTRICAL SCHEDULES E300 ELECTRICAL SINGLE-LINE DIAGRAM PROJECT SUMMARY KUHLMAN HALL IS A 7-STORY BRICK, CMU, AND CONCRETE STRUCTURE CONSTRUCTED IN 1966. KUHLMAN HALL IS CONNECTED TO HUSMAN HALL, BUILT 1964, AND SEPARATED BY A 12'-0" WIDE BREEZEWAY. HUSMAN HALL MECHANICAL AND ELECTRICAL SYSTEMS ARE FED THROUGH KUHLMAN HALL. SCOPE OF THIS PROJECT: 1. WORK ASSOCIATED WITH ELEVATOR MODERNIZATION

Transcript of KUHLMAN HALL PHASE III - Xavier University · kuhlman hall renovation phase iii xavier university...

Page 1: KUHLMAN HALL PHASE III - Xavier University · kuhlman hall renovation phase iii xavier university 3824 ledgewood drive cincinnati, ohio 45207 ... xavier university campus cincinnati,

G001

COVER

SHEET

JKF REB

APRIL 17, 2015

--

-

--

-

--

-

--

-

--

-

--

-

--

-

OFFICE OF PHYSICAL PLANT

XAVIER UNIVERSITY

3800 VICTORY PARKWAY

CINCINNATI, OH 45207

513-745-2037

DATE

SHEET NO.

DA

TE

RE

VIS

IO

NIS

SU

E

DRAWN BY: CHECKED BY:

PROJECT NUMBER

KU

HL

MA

N H

AL

L R

EN

OV

AT

IO

N

PH

AS

E III

XA

VIE

R U

NIV

ER

SIT

Y

3824 LE

DG

EW

OO

D D

RIV

E

CIN

CIN

NA

TI, O

HIO

45207

4/17/2015 10:48 A

MR

:\P

LA

NT

\D

ES

IG

N P

RO

JE

CT

S\K

UH

LM

AN

H

ALL\K

UH

LM

AN

2015 P

HA

SE

III - R

EV

IS

ED

\S

HE

ET

S\G

001 C

OV

ER

S

HE

ET

.D

WG

EXPIRATION DATE: 12/31/2015

RACHEL E. BIESIK, LICENSE #11710

911723

KUHLMAN HALL

RENOVATION

PHASE III

XAVIER UNIVERSITY

3824 LEDGEWOOD DRIVE

CINCINNATI, OHIO 45207

XAVIER UNIVERSITY CAMPUS

CINCINNATI, OH

75

71

75

75

75

71

71

71

71

75

74

126

126

126

562

126

42

22

22

22

42

42

50

50

50

50

50

42

27

27

27

27

27

127

127

127

27

CINCINNATI

471

N

O

R

W

O

O

D

L

A

T

E

R

A

L

R

O

N

A

L

D

R

E

A

G

A

N

H

IG

H

W

A

Y

R

O

N

A

L

D

R

E

A

G

A

N

H

IG

H

W

A

Y

XAVIER UNIVERSITY

SITE LOCATION

SHEET INDEX

SHEET NO SHEET TITLE

G001 COVER SHEET

LS100 LIFE SAFETY PLANS

LS101 LIFE SAFETY PLANS

A100 NEW GROUND FLOOR

A107 ROOF AND ELEVATOR MACHINE ROOM PLAN

HD107 H.V.A.C. - DEMOLITION - ROOF

HV107 H.V.A.C. - NEW DUCTWORK - ROOF

HV500 H.V.A.C. - COMCHECK

E000 ELECTRIC LEGEND

ED100 ELECTRIC DEMOLITION - GROUND FLOOR

ED107 ELECTRIC DEMOLITION - ROOF

E100 ELECTRIC - GROUND FLOOR

E107 ELECTRIC - ROOF

E201 ELECTRICAL SCHEDULES

E300 ELECTRICAL SINGLE-LINE DIAGRAM

PROJECT SUMMARY

KUHLMAN HALL IS A 7-STORY BRICK, CMU, AND CONCRETE STRUCTURE

CONSTRUCTED IN 1966. KUHLMAN HALL IS CONNECTED TO HUSMAN

HALL, BUILT 1964, AND SEPARATED BY A 12'-0" WIDE BREEZEWAY.

HUSMAN HALL MECHANICAL AND ELECTRICAL SYSTEMS ARE FED

THROUGH KUHLMAN HALL.

SCOPE OF THIS PROJECT:

1. WORK ASSOCIATED WITH ELEVATOR MODERNIZATION

Page 2: KUHLMAN HALL PHASE III - Xavier University · kuhlman hall renovation phase iii xavier university 3824 ledgewood drive cincinnati, ohio 45207 ... xavier university campus cincinnati,

1

1/16" = 1'-0"

GROUND FLOOR LIFE SAFETY PLAN

FEC

FEC

FEC

FE

INCIDENTAL

OCCUPANCY AREA

IS SPRINKLERED

ELEVATOR

LOBBY -

PART OF

EXIT

ACCESS

ACCESSIBLE ENTRANCE

(1 OF 2 MAIN ENTRANCES)

INCIDENTAL

OCCUPANCY AREA

IS SPRINKLERED

2

1/16" = 1'-0"

FIRST FLOOR LIFE SAFETY PLAN

FEC

FEC

FEC

FEC

ELEVATOR

LOBBY

3

1/16" = 1'-0"

SECOND FLOOR LIFE SAFETY PLAN

FE

FEC

FEC

FEC

EXISTING

CHAPEL

OCCUPANT

LOAD=

24 SEATS

ELEVATOR

LOBBY

1 HR FIRE-RATED PARTITION

2 HR FIRE RATED BARRIER

2 HR FIRE-RATED

VERTICAL SHAFTS

NOTE: ALL RATED WALLS AND SHAFTS ARE INDICATED ON

PLANS. THESE WALLS ARE NOT BEING UPGRADED.

ANY NEW WORK DONE TO THESE PARTITIONS SHALL

BE RATED ACCORDINGLY.

EXIT SIGN (EXISTING)

FE - FIRE EXTINGUISHER (EXISTING)

FEC - FIRE EXTINGUISHER CABINET (EXISTING)

EXISTING CONDITIONS

USE GROUP = R-2

CONSTRUCTION TYPE = 1B (NON-COMBUSTIBLE.)

STORIES = 7

FIRE PROTECTION SYSTEMS

AUTOMATIC SPRINKLER SYSTEM: BUILDING IS PARTIALLY

SPRINKLERED, NO CHANGE

AUTOMATIC FIRE ALARM SYSTEM: INSTALLED THROUGHOUT.

EXISTING BUILDING CONSTRUCTION = REINFORCED 12”X12”

CONCRETE COLUMNS AND 6” TWO WAY REINFORCED CONCRETE

SLABS.

FIRE RATING OF EXISTING FLOORS: 2 HOURS MINIMUM.

FIRE RATING OF EXISTING PARTITIONS: SEE LIFE SAFETY

DRAWINGS.

ACTUAL BUILDING FOOTPRINT OF HUSMAN HALL 13, 150 SF

BUILDING FOOTPRINT OF KUHLMAN HALL ADDITION 12, 656 SF

TOTAL 25, 807 SF

ALLOWABLE AREA = UL UNLIMITED

OCCUPANT LOAD

GROUND = 11,969 SF (TOTAL)

MINUS 1,040 SF (ACCESSORY STORAGE) 4

MINUS 914 SF (MECH. EQUIP. ROOM) 3

MINUS 1,123 SF (ASSEMBLY) 75

8,892 SF (REMAINDER) 178

TOTAL 260

1ST = 12,656 SF (TOTAL)

MINUS 840 SF (RESIDENTIAL) 5

11,816 SF (REMAINDER) 236

TOTAL 241

2ND = 12,430 SF (TOTAL)

MINUS 720 SF (RESIDENTIAL) 4

MINUS 560 SF (CHAPEL) 24

11,150 SF (REMAINDER) 223

TOTAL 251

3RD = 11,387 228

4TH= 11,387 228

5TH= 11,387 228

6TH= 11,387 228

FINISH REQUIREMENTS

INTERIOR WALL AND CEILING

EXIT ENCLOSURES & EXIT PASSAGEWAYS CLASS B

CORRIDORS CLASS B

ROOMS & ENCLOSED SPACES CLASS C

LS100

LIFE

SAFETY

PLANS

JKF REB

APRIL 17, 2015

--

-

--

-

--

-

--

-

--

-

--

-

--

-

OFFICE OF PHYSICAL PLANT

XAVIER UNIVERSITY

3800 VICTORY PARKWAY

CINCINNATI, OH 45207

513-745-2037

DATE

SHEET NO.

DA

TE

RE

VIS

IO

NIS

SU

E

DRAWN BY: CHECKED BY:

PROJECT NUMBER

KU

HL

MA

N H

AL

L R

EN

OV

AT

IO

N

PH

AS

E III

XA

VIE

R U

NIV

ER

SIT

Y

3824 LE

DG

EW

OO

D D

RIV

E

CIN

CIN

NA

TI, O

HIO

45207

4/17/2015 10:48 A

MR

:\P

LA

NT

\D

ES

IG

N P

RO

JE

CT

S\K

UH

LM

AN

H

ALL\K

UH

LM

AN

2015 P

HA

SE

III - R

EV

IS

ED

\S

HE

ET

S\LS

100 LIF

E S

AF

ET

Y P

LA

NS

.D

WG

EXPIRATION DATE: 12/31/2015

RACHEL E. BIESIK, LICENSE #11710

911723

Page 3: KUHLMAN HALL PHASE III - Xavier University · kuhlman hall renovation phase iii xavier university 3824 ledgewood drive cincinnati, ohio 45207 ... xavier university campus cincinnati,

2

1/16" = 1'-0"

FOURTH FLOOR LIFE SAFETY PLAN

FEC

FEC

FE

ELEVATOR

LOBBY

1

1/16" = 1'-0"

THIRD FLOOR LIFE SAFETY PLAN

FEC

FEC

FEC

ELEVATOR

LOBBY

S

3

1/16" = 1'-0"

FIFTH FLOOR LIFE SAFETY PLAN

FEC

FEC

FEC

ELEVATOR

LOBBY

S

4

1/16" = 1'-0"

SIXTH FLOOR LIFE SAFETY PLAN

FEC

FEC

FEC

ELEVATOR

LOBBY

1 HR FIRE-RATED PARTITION

2 HR FIRE RATED BARRIER

2 HR FIRE-RATED

VERTICAL SHAFTS

NOTE: ALL RATED WALLS AND SHAFTS ARE INDICATED ON

PLANS. THESE WALLS ARE NOT BEING UPGRADED.

ANY NEW WORK DONE TO THESE PARTITIONS SHALL

BE RATED ACCORDINGLY.

EXIT SIGN (EXISTING)

FE - FIRE EXTINGUISHER (EXISTING)

FEC - FIRE EXTINGUISHER CABINET (EXISTING)

EXISTING CONDITIONS

USE GROUP = R-2

CONSTRUCTION TYPE = 1B (NON-COMBUSTIBLE.)

STORIES = 7

FIRE PROTECTION SYSTEMS

AUTOMATIC SPRINKLER SYSTEM: BUILDING IS PARTIALLY

SPRINKLERED, NO CHANGE

AUTOMATIC FIRE ALARM SYSTEM: INSTALLED THROUGHOUT.

EXISTING BUILDING CONSTRUCTION = REINFORCED 12”X12”

CONCRETE COLUMNS AND 6” TWO WAY REINFORCED CONCRETE

SLABS.

FIRE RATING OF EXISTING FLOORS: 2 HOURS MINIMUM.

FIRE RATING OF EXISTING PARTITIONS: SEE LIFE SAFETY

DRAWINGS.

ACTUAL BUILDING FOOTPRINT OF HUSMAN HALL 13, 150 SF

BUILDING FOOTPRINT OF KUHLMAN HALL ADDITION 12, 656 SF

TOTAL 25, 807 SF

ALLOWABLE AREA = UL UNLIMITED

OCCUPANT LOAD

GROUND = 11,969 SF (TOTAL)

MINUS 1,040 SF (ACCESSORY STORAGE) 4

MINUS 914 SF (MECH. EQUIP. ROOM) 3

MINUS 1,123 SF (ASSEMBLY) 75

8,892 SF (REMAINDER) 178

TOTAL 260

1ST = 12,656 SF (TOTAL)

MINUS 840 SF (RESIDENTIAL) 5

11,816 SF (REMAINDER) 236

TOTAL 241

2ND = 12,430 SF (TOTAL)

MINUS 720 SF (RESIDENTIAL) 4

MINUS 560 SF (CHAPEL) 24

11,150 SF (REMAINDER) 223

TOTAL 251

3RD = 11,387 228

4TH= 11,387 228

5TH= 11,387 228

6TH= 11,387 228

FINISH REQUIREMENTS

INTERIOR WALL AND CEILING

EXIT ENCLOSURES & EXIT PASSAGEWAYS CLASS B

CORRIDORS CLASS B

ROOMS & ENCLOSED SPACES CLASS C

S

FE

5

1/16" = 1'-0"

PENTHOUSE LIFE SAFETY PLAN

LS101

LIFE

SAFETY

PLANS

JKF REB

APRIL 17, 2015

--

-

--

-

--

-

--

-

--

-

--

-

--

-

OFFICE OF PHYSICAL PLANT

XAVIER UNIVERSITY

3800 VICTORY PARKWAY

CINCINNATI, OH 45207

513-745-2037

DATE

SHEET NO.

DA

TE

RE

VIS

IO

NIS

SU

E

DRAWN BY: CHECKED BY:

PROJECT NUMBER

KU

HL

MA

N H

AL

L R

EN

OV

AT

IO

N

PH

AS

E III

XA

VIE

R U

NIV

ER

SIT

Y

3824 LE

DG

EW

OO

D D

RIV

E

CIN

CIN

NA

TI, O

HIO

45207

4/17/2015 10:48 A

MR

:\P

LA

NT

\D

ES

IG

N P

RO

JE

CT

S\K

UH

LM

AN

H

ALL\K

UH

LM

AN

2015 P

HA

SE

III - R

EV

IS

ED

\S

HE

ET

S\LS

101 LIF

E S

AF

ET

Y P

LA

NS

.D

WG

EXPIRATION DATE: 12/31/2015

RACHEL E. BIESIK, LICENSE #11710

911723

Page 4: KUHLMAN HALL PHASE III - Xavier University · kuhlman hall renovation phase iii xavier university 3824 ledgewood drive cincinnati, ohio 45207 ... xavier university campus cincinnati,

NEW FLOOR PLAN GENERAL NOTES

A. MECHANICAL AND ELECTRICAL FIXTURES SHOWN ON

ARCHITECTURAL DRAWINGS FOR REFERENCE ONLY.

REFER TO MECHANICAL AND ELECTRICAL DRAWINGS

FOR NEW AND EXISTING FIXTURE LOCATIONS AND

QUANTITIES.

NEW FLOOR PLAN KEYNOTES

1. PROVIDE NEW PORCELAIN TILE ON FLOOR OF EXISTING

ELEVATOR CABS. SEE SPECIFICATIONS. PROVIDE SHOP

DRAWING AND SAMPLE OF FINISH FOR ACCESS PLATE.

2. SCOPE OF ELEVATOR MODERNIZATION.

3. SEE ELEVATION 2/A100 FOR INFORMATION ABOUT NEW

HOISTWAY JAMB SIGNAGE.

4. PROVIDE REQUIRED RATED WALL INFILL PATCH,

MATCHING EXISTING WALL CONSTRUCTION WITH

PLASTER FINISH, AT EACH NEW ELEVATOR LOBBY HALL

STATION (FLOORS G-6) TO INFILL PRIOR INSTALLATIONS

OF HALL STATION PANELS. COORDINATE EXTENT AND

HEIGHT OF INFILL WITH ELEVATOR MANUFACTURER

INSTALLER.

5. REMOVE ALL EXISTING SIGNAGE. PLASTER AND PAINT

WHERE SIGNS AND FASTENERS WERE REMOVED,

MATCHING EXISTING FINISH AND COLOR. PROVIDE AND

INSTALL NEW "IN CASE OF FIRE USE STAIRS SIGN"

CENTERED BETWEEN DOORS AS SHOWN ON ELEVATION

7/A100. PROVIDE SUBMITTAL TO ARCHITECT FOR SIGN

VERIFICATION. INSTALL DIGITAL PRINT EVACUATION

SIGN INSIDE CLEAR ACRYLIC HOLDER AS SHOWN ON

ELEVATION 7/A100.

5'-0

"

1

2

3/4" = 1'-0"

HOISTWAY SIGNAGE

HOISTWAY SIGNAGE GENERAL NOTE

A. FLOOR DESIGNATION SHALL BE

ON BOTH JAMBS OF THE

ELEVATOR HOISTWAY ENTRANCE.

B. FLOOR DESIGNATIONS SHALL BE

PROVIDED IN BOTH TACTILE

CHARACTERS AND BRAILLE.

C. TACTILE CHARACTERS SHALL BE 2

INCHES (51 MM) HIGH MINIMUM.

D. A TACTILE STAR SHALL BE

PROVIDED ON BOTH JAMBS AT

THE MAIN ENTRY LEVEL (GROUND

LEVEL).

NEW HOISTWAY SIGNAGE ON INSIDE OF

ELEVATOR DOOR JAMB (BY OTHERS)

NEW REMOVABLE

CAST STAINLESS STEEL

ACCESS PLATE

NEW PORCELAIN TILE.

5/16" THICK W/ 3/16"

SETTING BED

NEW 5" DIAMETER x 1/16

" THICK STEEL PLATE

NEW ST ST NUT W/ SELF LOCKING

WASHER

EXISTING ACCESS

PLATE AND RECEIVER

TRIM TO REMAIN.

DRILL HOLE AS

NEEDED.

EXISTING STEEL CAB

FLOOR

NEW INTEGRAL CONCEALED

ST ST STUD

3

1

4

"

EXISTING ACCESS HOLE TO

REMAIN

NEW ST ST RECEIVER

TRIM. FASTEN TO

EXISTING PLYWOOD W/

COUNTERSUNK

FLATHEAD ST ST

SCREWS

SATIN FINISH

TEXTURED FINISH . PROVIDE

SAMPLES. SURFACE @ -1/16 "

2

3

4

"

1"

9"

NEW ST ST RECEIVER TRIM

NEW WATERPROOF

MEMBRANE

SATIN FINISH

1

2

"

SATIN FINISH

7"

NEW ST ST ACCES PLATE

1 2

"

NEW 1/4"

UNDERLAYMENT

CEMENT BOARD.

EXISTING WOOD

UNDERLAYMENT TO

REMAIN - IF SOLID.

SILICONE SEALANT

1/2" BACKER ROD

PORCELAIN TILE

ON SETTING BED

ST ST WALL BASE

BY ELEVATOR MFR

CEMENT BOARD

3 4

"

PERIMETER MOVEMENT JOINT DETAIL /

NEW TILE FLOOR FINISH OF ELEVATOR CAB

5

6"-1'-0"

NEW ACCESS PLATE / PLAN VIEW

4

6"-1'-0"

NEW ACCESS PLATE SECTION

6

6"-1'-0"

PERIMETER MOVEMENT JOINT

3 /16" WIDE GROUT

JOINT TYPICAL

3

1/4"=1'-0"

TYPICAL ELEVATOR FLOOR FINISH PLAN

NEW SCHLUTER

SCHIENE E125EB

NEW ACCESS PANEL. SEE

DTL 5/A100

PROVIDE 1/2" WIDE

MOVEMENT JOINT AT

PERIMETER . SEE DTL 6/A100

NEW PORCELAIN TILE, CEMENT

BOARD, AND WATERPROOF

MEMBRANE. SEE SPEC AND

DETAILS THIS SHEET.

4'-1"

6'-7"

4'-1"

6'-7"

REMOVE EXISTING ADJACENT

6” WIDE REDUCING

THRESHOLD AND PARTIAL

TILES. PATCH LOBBY FLOOR

TILE W/ LARGER PIECE TILES

IN

3

16

" MORTAR BED AND

PROVIDE SCHLUTER SCHIENE

E 125EB EDGE FLUSH W/ NEW

RAISED SILL. TYPICAL AT BOTH

DOORS ON ALL (7) LEVELS.

1

1

MA

TC

H

1

1/8" = 1'-0"

GROUND FLOOR PLAN

2

3

3

1

1

A100

3

4 5

MA

TC

H

7

1/2" = 1'-0"

LOBBY SIGNAGE

6'-0

"

DIGITAL PRINT

EVACUATION

SIGN INSIDE

CLEAR ACRYLIC

PLAN HOLDER,

11"X17"

"IN CASE OF

FIRE USE

STAIRS" SIGN,

6" X 7"

EQ EQ

3'-8

"

5'-2

"

A100

NEW

GROUND

FLOOR

JKF REB

APRIL 17, 2015

--

-

--

-

--

-

--

-

--

-

--

-

OFFICE OF PHYSICAL PLANT

XAVIER UNIVERSITY

3800 VICTORY PARKWAY

CINCINNATI, OH 45207

513-745-2037

DATE

SHEET NO.

DA

TE

RE

VIS

IO

NIS

SU

E

DRAWN BY: CHECKED BY:

PROJECT NUMBER

KU

HL

MA

N H

AL

L R

EN

OV

AT

IO

N

PH

AS

E III

XA

VIE

R U

NIV

ER

SIT

Y

3824 LE

DG

EW

OO

D D

RIV

E

CIN

CIN

NA

TI, O

HIO

45207

4/17/2015 10:48 A

MR

:\P

LA

NT

\D

ES

IG

N P

RO

JE

CT

S\K

UH

LM

AN

H

ALL\K

UH

LM

AN

2015 P

HA

SE

III - R

EV

IS

ED

\S

HE

ET

S\A

100 N

EW

G

RO

UN

D F

LO

OR

.D

WG

EXPIRATION DATE: 12/31/2015

RACHEL E. BIESIK, LICENSE #11710

911723

--

-

Page 5: KUHLMAN HALL PHASE III - Xavier University · kuhlman hall renovation phase iii xavier university 3824 ledgewood drive cincinnati, ohio 45207 ... xavier university campus cincinnati,

A107

ROOF AND

ELEVATOR

MACHINE

ROOM PLAN

JKF REB

APRIL 17, 2015

--

-

--

-

--

-

--

-

--

-

--

-

--

-

OFFICE OF PHYSICAL PLANT

XAVIER UNIVERSITY

3800 VICTORY PARKWAY

CINCINNATI, OH 45207

513-745-2037

DATE

SHEET NO.

DA

TE

RE

VIS

IO

NIS

SU

E

DRAWN BY: CHECKED BY:

PROJECT NUMBER

KU

HL

MA

N H

AL

L R

EN

OV

AT

IO

N

PH

AS

E III

XA

VIE

R U

NIV

ER

SIT

Y

3824 LE

DG

EW

OO

D D

RIV

E

CIN

CIN

NA

TI, O

HIO

45207

4/17/2015 10:48 A

MR

:\P

LA

NT

\D

ES

IG

N P

RO

JE

CT

S\K

UH

LM

AN

H

ALL\K

UH

LM

AN

2015 P

HA

SE

III - R

EV

IS

ED

\S

HE

ET

S\A

107 R

OO

F A

ND

E

LE

VA

TO

R M

AC

HIN

E R

OO

M P

LA

N.D

WG

EXPIRATION DATE: 12/31/2015

RACHEL E. BIESIK, LICENSE #11710

911723

NEW FLOOR PLAN GENERAL NOTES

A. MECHANICAL AND ELECTRICAL FIXTURES SHOWN ON

ARCHITECTURAL DRAWINGS FOR REFERENCE ONLY.

REFER TO MECHANICAL AND ELECTRICAL DRAWINGS

FOR NEW AND EXISTING FIXTURE LOCATIONS AND

QUANTITIES.

B. COORDINATE ALL WORK WITH MECHANICAL AND

ELECTRICAL DRAWINGS.

C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR

SPECIFIC INFORMATION ON PRODUCTS USED.

D. IF CONTRACTOR SHOULD DISCOVER ANY UNFORESEEN

PROBLEMS DURING THE REMOVAL OF ANY EXISTING

CONSTRUCTION OR THE CONSTRUCTION OF ANY NEW

WORK, THE ARCHITECT SHOULD BE NOTIFIED

IMMEDIATELY AND THAT PARTICULAR WORK SHOULD BE

DISCONTINUED UNTIL NECESSARY REVISIONS CAN BE

DECIDED UPON.

E. ALL CMU INFILL TO BE NOM. 4X8X16 IN SIZE. ALL FACE

BRICK INFILL TO NOM. 4X2-

1

2

X8. FILL COLLAR JOINT WITH

GROUT. SEE SPECIFICATIONS.

NEW FLOOR PLAN KEYNOTES

1. SCOPE OF ELEVATOR MODERNIZATION.

2. REMOVE THRU-WALL A/C UNIT WOOD FRAMING AND

PANEL, METAL THRU-WALL FRAME, AND ANY OTHER

INFILL PANELS. REMOVE PRIOR INFILL BRICK (12

BRICKS). PATCH OPENING (NOM. 1'-4"H X 3'-8"W) WITH

NOM. 4" CMU INSIDE AND NOM. 4" FACE BRICK ON THE

EXTERIOR. SEE GENERAL NOTE E.

3. REMOVE METAL THRU-WALL FRAME, BLANK-OFF PANELS

AND EXTERIOR LOUVER. PATCH OPENING (NOM. 1'-4"H X

3'-8"W) WITH NOM. 4" CMU INSIDE AND NOM. 4" FACE

BRICK ON THE EXTERIOR. SEE GENERAL NOTE E.

4. PATCH OPENING OF DEMO'D THRU-WALL EXHAUST UNIT

(NOM. 1'-4"H X 1'-4"W) WITH NOM. 4" CMU INSIDE AND

NOM. 4" FACE BRICK ON THE EXTERIOR. SEE GENERAL

NOTE E.

5. PREP AND PAINT EXTERIOR LOUVERS COLOR P-1.

6. PREP AND PAINT THE OUTSIDE ONLY OF THE EXTERIOR

DOOR COLOR P-1.

7. PACK ALL GAPS/HOLES AT FLOOR PENETRATIONS WITH

MINERAL WOOL. SEAL TOP OF MINERAL WOOL WITH

FIRE-RATED CAULK PER FIRESTOPPING

MANUFACTURER'S INSTRUCTIONS. REFER TO UL

DESIGN SYSTEM NO. C-AJ-1226. SEE FIRESTOPPING

SPECIFICATIONS.

NEW PAINTING SCHEDULE

P-1 MATCH EXISTING ELEVATOR MACHINE ROOM EXTERIOR

DOOR FRAME

(EXTERIOR DOOR AND LOUVERS)

MA

TC

H

1

1/8" = 1'-0"

NEW ROOF AND ELEVATOR MACHINE ROOM PLAN

1

A107

2

MA

TC

H

2

1/4" = 1'-0"

NEW ENLARGED ELEVATOR MACHINE ROOM PLAN

2

3

5

7

4

6

7