KP 013 Pump Reservoir Calculations
-
Upload
urielle-clayton -
Category
Documents
-
view
21 -
download
1
description
Transcript of KP 013 Pump Reservoir Calculations
KP 013 Pump Reservoir Calculations
• Oil Temperature- Although the pumps use cooling fins to help dissipate heat, we recommend that the continuous system temperature be kept at or below 195°F (90°C). It can see an intermittent temperature of 212°F (100°C) and a peak temperature of 230°F (110°C).
• Viscosity Rating- We recommend use of a 60 SUS (10cSt) viscosity hydraulic oil at no more than 212°F (100°C).
• Filter- Due to the precise machining and exact tolerances in the pump, White Hydraulics recommends a filter rating of 20 Micron absolute.
KP 013 Pump Reservoir Volume Calculations
Disp 0.79in3
rev Pump
Displacement
RPMmin 600rpm RPMmax 3600rpm Pump RPM (min& max)
RPMave
RPMmin RPMmax 2
RPMave 2100rpm Pump RPM(average)
Dispave Disp RPMave Pump AverageDisplacementCalculation
Dispave 27.65in3
sec
Dispave 453cm3
sec
Ressize 3sec( )DispaveRessize 1.359L Reservoir
VolumeCalculation
Ressize 82.95in3
Ressize 1359cm3
KP 013 Pump Reservoir Pressure Calculations
• Pending…
KP 013 Pump Reservoir Heat Transfer Calculations
• Pending…