Kone Details
description
Transcript of Kone Details
Architectural Planning Guide
2 KONE Architectural Planning Guide
KONE offers solutions for each phase of the building’s life cycle
Design SolutionsKONE can assist during the planning and design phases
by providing easy-to-use tools to help customers design
the right solutions for their project’s needs. KONE’s traffic
analysis and planning services help to define the optimal
amount of equipment and layout.
n Online Architectural Toolbox
n BIM Models
n Online Car Designer Tool
n Award-winning KONE Design Collection
Modernization Solutions KONE offers modernization solutions ranging from small
upgrades to full replacement.
n KONE Polaris™ Destination Control System
n KONE EcoSpace EB™
n KONE EcoMod®
n KONE Modulator Modernization Solutions
3KONE Architectural Planning Guide
Construction SolutionsKONE can offer the right solutions for almost any type
of building application from two to 100+ floors with KONE
EcoDisc® technology. Customers also have flexible escalator
options to serve retail, transit and commercial environments.
n KONE EcoSpace™
n KONE MonoSpace®
n KONE EcoSystem MR™
n KONE TravelMaster™ 110
n KONE TransitMaster™ 140
Installation SolutionsKONE’s experienced project management teams guarantee
smooth coordination with all parties involved. Our proven
installation methods save on installation time and costs.
n Project management and installation services
n Construction time use
n KONE major projects unit
Maintenance SolutionsKONE offers preventative maintenance, monitoring and
web-based reporting services that maximize reliability
and safety while minimizing downtime.
n KONE Care™ maintenance solutions
n Spare parts
n KONE KRMS™ Remote Monitoring for elevators
n KONE eOptimum™ Web-based Performance Information Program
4 KONE Architectural Planning Guide
Redefining Elevator TechnologyKONE EcoDiscProven Technologyn More than 15 years of experience with KONE EcoDisc technology,
including the world’s first Machine Room-Less (MRL) installation
n KONE has sold and installed over 440,000 KONE EcoDisc machines worldwide
n Applicable from 2 to 100+ floors
Space Savingsn In low- to mid-rise elevators, the compact KONE EcoDisc structure eliminates
the traditional machine room and, in some cases, the control room
n In high-rise systems, the KONE EcoDisc delivers remarkable space savings and improved efficiency
MRLMachine Room-Less
MRMachine Room Above
KONE Eco-efficient™ solutionsHow much can you save by selecting right?KONE elevators can reduce the total energy consumption by as much as two-thirds or even more. For example, a KONE EcoSpace elevator, with the KONE EcoDisc hoisting machine, uses up to 70% less energy compared to a hydraulic elevator and up to 50% less than a 2-speed traction elevator. With additional energy-saving features, this energy consumption can be reduced even further.
A green hoisting systemThe KONE EcoDisc hoisting machine made DC gearless and inefficient geared hoisting machines obsolete. The KONE EcoDisc permanent-magnet synchronous motor, together with a vector-controlled drive system and regenerative options, provide the highest total efficiency and minimize both mechanical and electrical losses.
Regenerative driveRecovers excess energy from the elevator when the KONE EcoDisc motor acts as a generator. This most notably occurs with an empty car traveling UP or a full car traveling DOWN. The drive can recover up to 25% of the total energy used by an elevator, producing clean and safe energy that does not damage the network.
Put to sleep when not in useIn today’s elevators, lights, signalization and ventilation can consume a considerable amount of electricity even when the elevator is not moving. KONE energy-efficient options supervise elevator usage and set the devices to sleep mode during inactive periods to minimize total energy consumption.
Eco-efficient car lightingTo save energy used for car lighting, halogen lights have been replaced by LED spot lights. LED lights consume 80% less electricity than halogen lights and last up to 10 times longer.
1
2
3
4
EcoDisc Applications
1
2
3
4
5KONE Architectural Planning Guide
Select your KONE EcoDisc-powered elevator
Application New Construction & Modernization
Ideal Scenario min. 3 elevators and 6 landings
With KONE Polaris, passengers select their destination and are guided directly to the dedicated car. A limited number of other passengers within a specific range of floors are assigned to the same car. Boarding is calm, orderly and the traveling time to destination is minimized.
n Increased handling capacity
n Less waiting, fewer intermediate stops
n Improved comfort
n Enhanced security
n Greater personalization
n Easier accessibility
n Additional guidance
n More space
KONE Polaris
Application Low-Rise
Type MRL
Powered by EcoDisc
Capacity 2000 – 5000 lbs. (907 – 2268 kg)
Speed 200 – 350 fpm (1.0 – 1.78 m/s)
Landings 2 to 12
Machine Room-Less performance in a new or existing hoistway: Designed specifically to fit in the hydraulic footprint, KONE EcoSpace delivers pure traction Machine Room-Less performance to low-rise buildings.
n No oil
n No hole drilling
n Uses 70% less energy than hydraulic applications
n Minimal building interface
n Ideal solution for replacement of existing hydraulic elevator (contact KONE Sales Professional)
*Optional Control Closet or Room
KONE EcoSpace
For the latest product information and interactive design tools, visit www.kone.us
Application Mid-Rise
Type MRL
Powered by EcoDisc
Capacity 2000 – 5000 lbs. (907 – 2268 kg)
Speed 200 – 500 fpm (1.0 – 2.54 m/s)
Landings 6 to 27
The Machine Room-Less solution that launched a revolution: Introduced over a decade ago, KONE MonoSpace forever changed the vertical transportation landscape by eliminating the requirement for a machine room.
n Consumes approximately 50% less energy than conven-tional traction machines
n Creates more usable space – variable machine locations
n Superior ride quality
n Minimal building interface
KONE MonoSpace
Application Mid- to High-Rise
Type MR
Powered by EcoDisc
Capacity 2000 – 5000 lbs. (907 – 2268 kg)
Speed 200 – 700 fpm (1.0 – 3.5 m/s)
Landings 6 to 63
Innovative, space efficient, mid-high rise system: KONE EcoSystem MR elevators use next-generation KONE EcoDisc hoisting machines that require only half the overhead machine room space of traditional traction elevators.
n Energy efficient
n Superior acceleration/deceleration profile
n Improved floor-floor times and leveling
KONE EcoSystem MR
Notes(1) A hoist beam (by KONE) is required for installation (by others).
Dimension H reflects clear under hoist beam.
(2) If an EBD (Emergency Battery Device) is required, please contact your KONE Sales Professional for further detail regarding dimensions H , J and L .
(3) The published hoistway A dimensions represent the minimum clear inside requirements. Construction efficiencies can be realized by increasing these dimensions by up to 2" (51 mm).
(4) For pit depths less than 5'-0" (1524 mm) please contact a KONE Sales Professional.
(5) If occupied space exists below the hoistway, consult your KONE Sales Professional.
(6) All dimensions are based on an 8'-0" (2438 mm) cab with a 7'-0" (2134 mm) door. Alternate car and door heights are available, but will affect dimension H .
(7) Contact your local KONE Sales Representative regarding local code variations when utilizing the integrated, integral and remote closet options.
(8) 150 fpm (.75 m/s) only available up to 85 ft. (25 m) of travel and 10 landings. 200 fpm (1.00 m/s) available up to 100 ft. (30.5 m) of travel and 12 landings.
(9) 150 fpm (.75m/s) is maximum speed available for capacities greater than 3,500 lbs. (1588 kg).
Visit www.kone.us for the latest job-specific details, CAD drawings, specifications, electrical data, reaction loads and building access requirements.
KONE Architectural Planning Guide6
KONE EcoSpace Innovation Meets Affordability MAX TRAVEL(10) 150 ft. (45.7 m)
MAX LANDINGS(10) 15
SPEED(10,11) 150, 200, 350 fpm (.75, 1.0, 1.78 m/s)
CAR HEIGHT 8, 9 or 10 ft. (2438, 2743 or 3048 mm)
ENTRANCE HEIGHT 7, 8 or 9 ft. (2134, 2438 or 2743 mm)
F
G
Integral or Remote Control Closet
(option 1)
(2)
K
LJ
Adjacent or Remote
Control Room (option 2)
B
L
J
Plan Views
Integrated Controller Space
(standard)
(3)
(3) (4) (5)
AC
D B
E
Section View
H F G
TRAVEL G
I(6)
(1)
Co
ntr
ol S
pac
e CAPACITY lbs. (kg) CONTROLLER SPACE WIDTH (mm) DEPTH (mm) DOOR WIDTH (mm)
2000 to 5000 integral or remote closet 4'-0" 1'-8" 3'-6" (907 to 2268) (1219) (508) (1067) 2000 to 5000 adjacent room 5'-0" dimension (B) 3'-0" (907 to 2268) (1524) (914)
SERV
ICE
PASS
ENG
ER
Fro
nt
& R
ever
se O
pen
ing
Fro
nt
Op
enin
g
SERV
ICE
PASS
ENG
ER
CAPACITY OPENING HOISTWAY HOISTWAY HOISTWAY INTERIOR INTERIOR DOOR lbs. (kg) TYPE WIDTH (mm) WIDTH (mm) DEPTH (mm) WIDTH (mm) DEPTH (mm) WIDTH (mm)
2000 (907) SSP 7'-4" (2235) 7'-8" (2337) 5'-9" (1753) 5'-8" (1727) 4'-3" (1295) 3'-0" (914) 2500 (1134) SSP-CO 8'-4" (2540) 8'-8" (2642) 5'-9" (1753) 6'-8" (2032) 4'-3" (1295) 3'-6" (1067) 3000 (1361) SSP-CO 8'-6" (2591) 8'-8" (2642) 6'-3" (1905) 6'-8" (2032) 5'-0" (1524) 3'-6" (1067) 3500 (1588) SSP-CO 8'-6" (2591) 8'-8" (2642) 6'-11" (2108) 6'-8" (2032) 5'-63⁄16" (1681) 3'-6" (1067) 4000 (1814) CO 9'-4" (2845) 9'-4" (2845) 6'-11" (2108) 7'-513⁄16" (2281) 5'-63⁄16" (1681) 4'-0" (1219)
4000 (1814) 2SP 7'-4" (2235) 7'-4" (2235) 9'-2" (2794) 5'-63⁄16" (1681) 7'-77⁄16" (2323) 4'-0" (1219) 4500 (2041) 2SP 7'-4" (2235) 7'-4" (2235) 9'-8" (2946) 5'-63⁄16" (1681) 8'-13⁄8" (2473) 4'-0" (1219) 5000 (2268) 2SP 7'-4" (2235) 7'-4" (2235) 10'-21⁄4" (3105) 5'-63⁄16" (1681) 8'-93⁄16" (2672) 4'-0" (1219)
2000 (907) SSP 7'-4" (2235) 7'-8" (2337) 6'-31⁄4" (1911) 5'-8" (1727) 4'-3" (1295) 3'-0" (914) 2500 (1134) SSP-CO 8'-4" (2540) 8'-8" (2642) 6'-31⁄4" (1911) 6'-8" (2032) 4'-3" (1295) 3'-6" (1067) 3000 (1361) SSP-CO 8'-6" (2591) 8'-8" (2642) 6'-11" (2108) 6'-8" (2032) 5'-0" (1524) 3'-6" (1067) 3500 (1588) SSP-CO 8'-6" (2591) 8'-8" (2642) 7'-51⁄4" (2267) 6'-8" (2032) 5'-63⁄16" (1681) 3'-6" (1067) 4000 (1814) CO 9'-4" (2845) 9'-4" (2845) 7'-51⁄4" (2267) 7'-513⁄16" (2281) 5'-63⁄16" (1681) 4'-0" (1219)
4000 (1814) 2SP 7'-4" (2235) 7'-4" (2235) 10'-11⁄2" (3086) 5'-63⁄16" (1681) 7'-77⁄16" (2323) 4'-0" (1219) 4500 (2041) 2SP 7'-4" (2235) 7'-4" (2235) 10'-71⁄2" (3238) 5'-63⁄16" (1681) 8'-13⁄8" (2473) 4'-0" (1219) 5000 (2268) 2SP 7'-4" (2235) 7'-4" (2235) 11'-31⁄4" (3435) 5'-63⁄16" (1681) 8'-93⁄16" (2672) 4'-0" (1219)
EcoSpace A B C D E
J K L
CLEAR OVERHEAD AND PIT DEPTH
CAPACITY LBS. (kg)150 FPM (.75 m/s) 200 FPM (1.00 m/s) 350 FPM (1.78 m/s)
Pit Depth (mm) Clear Overhead (mm)
Pit Depth (mm) Clear Overhead (mm)
Pit Depth (mm) Clear Overhead (mm)
2000 to 3500 (907 to 1588) 5'-0" (1524) 13'-0" (3962) 5'-0" (1524) 13'-1" (3988) 5'-6" (1676) 13'-4" (4064)
4000 to 5000 (1814 to 2268) 5'-0" (1524) 13'-0" (3962) – – – –
IH
A SEISMIC
KONE Architectural Planning Guide 7
KO
NE Eco
Space
KO
NE M
on
oSp
ace K
ON
E EcoSystem
MR
KO
NE Po
laris
12
3
4
5
6
Space Efficiency Possibility to accommodate reduced headroom height and pit depth. The KONE EcoDisc machine is so compact there is no need for a machine room above, as it fits right into the hoistway. *Optional Control Closet or Room.
Energy-efficient The revolutionary gearless KONE EcoDisc machine has only one moving part and is three times more efficient than a hydraulic-powered unit using 70% less energy – with the potential to cut annual operating costs in half or better – a true energy miracle.
Minimal Disruption KONE EcoSpace EB fits inside the existing hydraulic hoistway, minimizing the need for modifications.
Reusable Entrances KONE EcoSpace EB reduces significant structural modifications by seamlessly interfacing with most existing hydraulic entrances.
Modern, Code-compliant Modern, simple and code-compliant operating displays.
High Performance Optimal stopping accuracy for a smooth ride.
No Oil The hydraulic cylinder is drained of all oil and capped, ensuring oil-free, environmentally-friendly operation.
KONE EcoSpace is also applicable for existing buildings with hydraulic elevators. This turnkey solution replaces the hydraulic system with innovative MRL technology.
Why Replace?Instead of replacing your old elevators with similar technology, KONE offers you a new choice. Our innovative Machine Room-Less design is the first turnkey full replacement elevator solution for existing hydraulic elevators. Thanks to the revolutionary KONE EcoDisc motor, KONE EcoSpace EB fits into the existing hydraulic hoistway with capability to seamlessly interface with your existing entrances.
KONE has sold over 440,000 KONE EcoDisc machines globally, with an excellent record of operating reliability. So, instead of complicated, lengthy and expensive retrofit upgrades, KONE provides a brand new elevator.
n Everything from the site survey to the dismantling of the existing equipment is carefully thought out in order to minimize disruption to your building.
n Our optimized maintenance program minimizes downtime and ensures safe and reliable lifetime operation.
KONE EcoSpace EB Advantagesn For the owner: Minimized building
disruption, increased property value, accommodates reduced pit depth and overhead
n For the tenant: Smoother, quieter ride, no hydraulic oil odor, optimum stopping accuracy, sophisticated car features
n For the environment: No hydraulic oil, energy-efficient, recycle existing elevator where feasible, minimize building materials
KONE EcoSpace EB The Benefits are Clear
2
3
4
5
6
7
1
7
8 KONE Architectural Planning Guide
2000 to 4000 integral or remote cabinet 4'-4" 1'-8" 4'-0" (907 to 1814) (1321) (508) (1219)
2000 to 4000 adjacent or remote room 5'-0" dimension (B) 3'-0" (907 to 1814) (1524) (914)
2000 to 5000 AIA integral or remote cabinet 4'-4" 1'-8" 4'-0" (907 to 2268) (1321) (508) (1219)
2000 to 5000 AIA adjacent or remote room 5'-0" dimension (B) 3'-0" (907 to 2268) (1524) (914)
2000 5'-4" (1626) 13'-1" (3988) – – – – 2500 – 3500 5'-5" (1651) 13'-7" (4140) 5'-5" (1651) 13'-11" (4242) 5'-5" (1651) 13'-11" (4242) 4000 5'-8" (1728) 13'-7" (4140) 5'-8" (1728) 13'-11" (4242) 5'-8" (1727) 13'-11" (4242) 4500 5'-8" (1728) 14'-0" (4267) 5'-11" (1803) 14'-3" (4343) – – 5000 – 5000 AIA 5'-11" (1803) 14'-5" (4394) 5'-11" (1803) 14'-10" (4521) – –
2000 (907) 5'-4" (1626) 13'-1" (3988) – – – – 2500 (1134) 5'-3" (1600) 13'-7" (4140) 5'-5" (1651) 13'-11" (4242) 5'-5" (1651) 13'-11" (4242) 3000 (1361) 5'-5" (1651) 13'-7" (4140) 5'-5" (1651) 14'-4" (4369) 5'-5" (1651) 14'-4" (4369) 3500 (1588) 5'-5" (1651) 13'-7" (4140) 5'-5" (1651) 14'-9" (4496) 5'-5" (1651) 14'-9" (4496) 4000 (1814) 5'-8" (1727) 13'-7" (4140) 5'-8" (1727) 14'-11" (4547) 7'-3" (2210) 15'-8" (4775) 4500 (2141) 5'-8" (1727) 14'-9" (4496) 5'-11" (1803) 15'-3" (4648) 7'-6" (2286) 16'-0" (4877) 5000 – 5000 AIA 5'-11" (1803) 15'-2" (4623) 5'-11" (1803) 15'-11" (4551) – – (2268)
CAPACITYlbs. (kg)
2000 (907)2500 (1134)3000 (1361)3500 (1588)4000 (1814)
PASS
ENG
ERPA
SSEN
GER
PASS
ENG
ERSE
RVIC
ESE
RVIC
E
Fro
nt
Op
enin
g
Clear Overhead and Pit Depth
Co
ntr
ol S
pac
eFr
on
t &
Rev
erse
Op
enin
gFr
on
t O
pen
ing
OPENINGTYPE
SSPSSP-COSSP-COSSP-CO
CO
HOISTWAYWIDTH (mm)
7'-4" (2235)8'-4" (2540)8'-4" (2540)8'-4" (2540)9'-4" (2845)
AA
CAPACITYlbs. (kg)
2000 (907)2500 (1134)3000 (1361)3500 (1588)4000 (1814)
4000 (1814)4500 (2041)5000 (2268)
5000 AIA (2268)
2500 (1134)3000 (1361)3500 (1588)4000 (1814)
4000 (1814)4500 (2041)5000 (2268)
5000 AIA (2268)
OPENINGTYPE
SSPSSP-COSSP-COSSP-CO
CO
2SP2SP2SP2SP
SSP-COSSP-COSSP-CO
CO
2SP2SP2SP2SP
INTERIORDEPTH (mm)
4'-31⁄4" (1302)4'-31⁄4" (1302)4'-91⁄4" (1454)5'-51⁄4" (1657)5'-51⁄4" (1657)
7'-6" (2286)8'-0 " (2438)8'-73⁄4" (2635)9'-0" (2743)
4'-33⁄4" (1314)4'-93⁄4" (1467)5'-53⁄4" (1670)5'-53⁄4" (1670)
7'-61⁄2" (2299)8'-01⁄2" (2451)8'-81⁄4" (2648)9'-0" (2743)
DDHOISTWAY
WIDTH (mm)
8'-4" (2540)9'-9" (2972)9'-9" (2972)9'-9" (2972)
10'-9" (3277)
8'-9" (2667)8'-9" (2667)8'-9" (2667)8'-9" (2667)
9'-9" (2972)9'-9" (2972)9'-9" (2972)
10'-9" (3277)
8'-9" (2667)8'-9" (2667)8'-9" (2667)8'-9" (2667)
HOISTWAYDEPTH (mm)
6'-7" (2007)7'-1" (2159)7'-4" (2235)7'-8" (2337)7'-8" (2337)
9'-8" (2946)10'-2" (3099)10'-5" (3175)
10'-103⁄4" (3321)
7'-1" (2159)7'-6" (2286)
7'-91⁄2" (2375)7'-91⁄2" (2375)
10'-1" (3073)10'-7" (3226)
11'-23⁄4" (3422)11'-63⁄4" (3524)
DOORWIDTH (mm)
3'-0" (914)3'-6" (1067)3'-6" (1067)3'-6" (1067)4'-0" (1219)
4'-0" (1219)4'-0" (1219)4'-6" (1372)*4'-6" (1372)*
3'-6" (1067)3'-6" (1067)3'-6" (1067)4'-0" (1219)
4'-0" (1219)4'-0" (1219)4'-6" (1372)*4'-6" (1372)*
EEINTERIOR
WIDTH (mm)
5'-81⁄2" (1740)6'-81⁄2" (2045)6'-81⁄2" (2045)6'-81⁄2" (2045)7'-81⁄2" (2350)
5'-81⁄2" (1740)5'-81⁄2" (1740)5'-81⁄2" (1740)5'-81⁄2" (1740)
6'-81⁄2" (2045)6'-81⁄2" (2045)6'-81⁄2" (2045)7'-81⁄2" (2350)
5'-81⁄2" (1740)5'-81⁄2" (1740)5'-81⁄2" (1740)5'-81⁄2" (1740)
CCHOISTWAY
DEPTH (mm)
6'-4" (1930)6'-10" (2083)7'-1" (2159)7'-5" (2261)7'-5" (2261)
9'-5" (2870)9'-11" (3023)10'-2" (3099)
10'-73⁄4" (3245)
7'-1" (2159)7'-6" (2286)
7'-91⁄2" (2375)7'-91⁄2" (2375)
10'-1" (3073)10'-7" (3226)
11'-23⁄4" (3422)11'-63⁄4" (3524)
BBHOISTWAY
WIDTH (mm)
8'-0" (2438)9'-5" (2870)9'-5" (2870)9'-5" (2870)10'-5" (3175)
8'-5" (2565)8'-5" (2565)8'-5" (2565)8'-5" (2565)
9'-5" (2870)9'-5" (2870)9'-5" (2870)10'-5" (3175)
8'-5" (2565)8'-5" (2565)8'-5" (2565)8'-5" (2565)
AA
HOISTWAYDEPTH (mm)
6'-8" (2032)6'-8" (2032)7'-2" (2184)
7'-10" (2388)7'-10" (2388)
BB
CAPACITYlbs. (kg)
2000(907)
2500(1134)
3000(1361)
3500(1588)
4000(1814)
INTERIORWIDTH (mm)
5'-81⁄2" (1740)6'-81⁄2" (2045)6'-81⁄2" (2045)6'-81⁄2" (2045)7'-81⁄2" (2350)
CCINTERIOR
DEPTH (mm)
4'-31⁄4" (1302)4'-31⁄4" (1302)4'-91⁄4" (1454)5'-51⁄4" (1657)5'-51⁄4" (1657)
DDDOOR
WIDTH (mm)
3'-0" (914)3'-6" (1067)3'-6" (1067)3'-6" (1067)4'-0" (1219)
EE
HH II
HOISTWAYWIDTH (mm)
7'-8" (2337)8'-8" (2642)8'-8" (2642)8'-8" (2642)9'-8" (2946)
AA SEISMIC
AA SEISMIC BB SEISMIC
200 FPM (1.00 m/s) 350 FPM (1.78 m/s) 500 FPM (2.54 m/s)
CLEAROVERHD (mm)
16'-11"(5156)
16'-11(5156)
16'-11(5156)
16'-11(5156)
16'-11(5156)
SEISMICHHPIT DEPTH
(mm)
5'-3"(1600)
5'-3"(1600)
5'-3"(1600)
5'-5"(1651)
5'-6"(1676)
SEISMICIICLEAR
OVERHD (mm)
15'-6"(4724)
15'-0"(4572)
15'-2"(4623)
14'-10"(4521)
15'-1"(4597)
HHPIT DEPTH
(mm)
5'-3"(1600)
5'-3"(1600)
5'-3"(1600)
5'-5"(1651)
5'-6"(1676)
IICLEAR
OVERHD (mm)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
SEISMICHHPIT DEPTH
(mm)
6'-7"(2007)
6'-5"(1956)
6'-5"(1956)
6'-5"(1956)
6'-6"(1981)
SEISMICIICLEAR
OVERHD (mm)
16'-11"(5156)
16'-7"(5055)
16'-10"(5131)
16'-4"(4978)
16'-7"(5055)
HHPIT DEPTH
(mm)
5'-7"(1702)
5'-5"(1651)
5'-5"(1651)
5'-5"(1651)
5'-6"(1676)
IICLEAR
OVERHD (mm)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
SEISMICHHPIT DEPTH
(mm)
6'-7"(2007)
6'-5"(1956)
6'-5"(1956)
6'-5"(1956)
8"-5"(2565)
SEISMICIICLEAR
OVERHD (mm)
16'-11"(5156)
16'-7"(5055)
16'-10"(5131)
16'-4"(4978)
16'-11"(5156)
HHPIT DEPTH
(mm)
5'-7"(1702)
5'-5"(1651)
5'-5"(1651)
5'-5"(1651)
7'-5"(2261)
II
2000 to 4000 integral or remote cabinet 4'-4" 1'-8" 4'-0" (907 to 1814) (1321) (508) (1219)
2000 to 4000 adjacent or remote room 5'-0" dimension (B) 3'-0" (907 to 1814) (1524) (914)
2000 to 5000 AIA integral or remote cabinet 4'-4" 1'-8" 4'-0" (907 to 2268) (1321) (508) (1219)
2000 to 5000 AIA adjacent or remote room 5'-0" dimension (B) 3'-0" (907 to 2268) (1524) (914)
2000 5'-4" (1626) 13'-1" (3988) – – – – 2500 – 3500 5'-5" (1651) 13'-7" (4140) 5'-5" (1651) 13'-11" (4242) 5'-5" (1651) 13'-11" (4242) 4000 5'-8" (1728) 13'-7" (4140) 5'-8" (1728) 13'-11" (4242) 5'-8" (1727) 13'-11" (4242) 4500 5'-8" (1728) 14'-0" (4267) 5'-11" (1803) 14'-3" (4343) – – 5000 – 5000 AIA 5'-11" (1803) 14'-5" (4394) 5'-11" (1803) 14'-10" (4521) – –
2000 (907) 5'-4" (1626) 13'-1" (3988) – – – – 2500 (1134) 5'-3" (1600) 13'-7" (4140) 5'-5" (1651) 13'-11" (4242) 5'-5" (1651) 13'-11" (4242) 3000 (1361) 5'-5" (1651) 13'-7" (4140) 5'-5" (1651) 14'-4" (4369) 5'-5" (1651) 14'-4" (4369) 3500 (1588) 5'-5" (1651) 13'-7" (4140) 5'-5" (1651) 14'-9" (4496) 5'-5" (1651) 14'-9" (4496) 4000 (1814) 5'-8" (1727) 13'-7" (4140) 5'-8" (1727) 14'-11" (4547) 7'-3" (2210) 15'-8" (4775) 4500 (2141) 5'-8" (1727) 14'-9" (4496) 5'-11" (1803) 15'-3" (4648) 7'-6" (2286) 16'-0" (4877) 5000 – 5000 AIA 5'-11" (1803) 15'-2" (4623) 5'-11" (1803) 15'-11" (4551) – – (2268)
CAPACITYlbs. (kg)
2000 (907)2500 (1134)3000 (1361)3500 (1588)4000 (1814)
PASS
ENG
ERPA
SSEN
GER
PASS
ENG
ERSE
RVIC
ESE
RVIC
E
Fro
nt
Op
enin
g
Clear Overhead and Pit Depth
Co
ntr
ol S
pac
eFr
on
t &
Rev
erse
Op
enin
gFr
on
t O
pen
ing
OPENINGTYPE
SSPSSP-COSSP-COSSP-CO
CO
HOISTWAYWIDTH (mm)
7'-4" (2235)8'-4" (2540)8'-4" (2540)8'-4" (2540)9'-4" (2845)
AA
CAPACITYlbs. (kg)
2000 (907)2500 (1134)3000 (1361)3500 (1588)4000 (1814)
4000 (1814)4500 (2041)5000 (2268)
5000 AIA (2268)
2500 (1134)3000 (1361)3500 (1588)4000 (1814)
4000 (1814)4500 (2041)5000 (2268)
5000 AIA (2268)
OPENINGTYPE
SSPSSP-COSSP-COSSP-CO
CO
2SP2SP2SP2SP
SSP-COSSP-COSSP-CO
CO
2SP2SP2SP2SP
INTERIORDEPTH (mm)
4'-31⁄4" (1302)4'-31⁄4" (1302)4'-91⁄4" (1454)5'-51⁄4" (1657)5'-51⁄4" (1657)
7'-6" (2286)8'-0 " (2438)8'-73⁄4" (2635)9'-0" (2743)
4'-33⁄4" (1314)4'-93⁄4" (1467)5'-53⁄4" (1670)5'-53⁄4" (1670)
7'-61⁄2" (2299)8'-01⁄2" (2451)8'-81⁄4" (2648)9'-0" (2743)
DDHOISTWAY
WIDTH (mm)
8'-4" (2540)9'-9" (2972)9'-9" (2972)9'-9" (2972)
10'-9" (3277)
8'-9" (2667)8'-9" (2667)8'-9" (2667)8'-9" (2667)
9'-9" (2972)9'-9" (2972)9'-9" (2972)
10'-9" (3277)
8'-9" (2667)8'-9" (2667)8'-9" (2667)8'-9" (2667)
HOISTWAYDEPTH (mm)
6'-7" (2007)7'-1" (2159)7'-4" (2235)7'-8" (2337)7'-8" (2337)
9'-8" (2946)10'-2" (3099)10'-5" (3175)
10'-103⁄4" (3321)
7'-1" (2159)7'-6" (2286)
7'-91⁄2" (2375)7'-91⁄2" (2375)
10'-1" (3073)10'-7" (3226)
11'-23⁄4" (3422)11'-63⁄4" (3524)
DOORWIDTH (mm)
3'-0" (914)3'-6" (1067)3'-6" (1067)3'-6" (1067)4'-0" (1219)
4'-0" (1219)4'-0" (1219)4'-6" (1372)*4'-6" (1372)*
3'-6" (1067)3'-6" (1067)3'-6" (1067)4'-0" (1219)
4'-0" (1219)4'-0" (1219)4'-6" (1372)*4'-6" (1372)*
EEINTERIOR
WIDTH (mm)
5'-81⁄2" (1740)6'-81⁄2" (2045)6'-81⁄2" (2045)6'-81⁄2" (2045)7'-81⁄2" (2350)
5'-81⁄2" (1740)5'-81⁄2" (1740)5'-81⁄2" (1740)5'-81⁄2" (1740)
6'-81⁄2" (2045)6'-81⁄2" (2045)6'-81⁄2" (2045)7'-81⁄2" (2350)
5'-81⁄2" (1740)5'-81⁄2" (1740)5'-81⁄2" (1740)5'-81⁄2" (1740)
CCHOISTWAY
DEPTH (mm)
6'-4" (1930)6'-10" (2083)7'-1" (2159)7'-5" (2261)7'-5" (2261)
9'-5" (2870)9'-11" (3023)10'-2" (3099)
10'-73⁄4" (3245)
7'-1" (2159)7'-6" (2286)
7'-91⁄2" (2375)7'-91⁄2" (2375)
10'-1" (3073)10'-7" (3226)
11'-23⁄4" (3422)11'-63⁄4" (3524)
BBHOISTWAY
WIDTH (mm)
8'-0" (2438)9'-5" (2870)9'-5" (2870)9'-5" (2870)10'-5" (3175)
8'-5" (2565)8'-5" (2565)8'-5" (2565)8'-5" (2565)
9'-5" (2870)9'-5" (2870)9'-5" (2870)10'-5" (3175)
8'-5" (2565)8'-5" (2565)8'-5" (2565)8'-5" (2565)
AA
HOISTWAYDEPTH (mm)
6'-8" (2032)6'-8" (2032)7'-2" (2184)
7'-10" (2388)7'-10" (2388)
BB
CAPACITYlbs. (kg)
2000(907)
2500(1134)
3000(1361)
3500(1588)
4000(1814)
INTERIORWIDTH (mm)
5'-81⁄2" (1740)6'-81⁄2" (2045)6'-81⁄2" (2045)6'-81⁄2" (2045)7'-81⁄2" (2350)
CCINTERIOR
DEPTH (mm)
4'-31⁄4" (1302)4'-31⁄4" (1302)4'-91⁄4" (1454)5'-51⁄4" (1657)5'-51⁄4" (1657)
DDDOOR
WIDTH (mm)
3'-0" (914)3'-6" (1067)3'-6" (1067)3'-6" (1067)4'-0" (1219)
EE
HH II
HOISTWAYWIDTH (mm)
7'-8" (2337)8'-8" (2642)8'-8" (2642)8'-8" (2642)9'-8" (2946)
AA SEISMIC
AA SEISMIC BB SEISMIC
200 FPM (1.00 m/s) 350 FPM (1.78 m/s) 500 FPM (2.54 m/s)
CLEAROVERHD (mm)
16'-11"(5156)
16'-11(5156)
16'-11(5156)
16'-11(5156)
16'-11(5156)
SEISMICHHPIT DEPTH
(mm)
5'-3"(1600)
5'-3"(1600)
5'-3"(1600)
5'-5"(1651)
5'-6"(1676)
SEISMICIICLEAR
OVERHD (mm)
15'-6"(4724)
15'-0"(4572)
15'-2"(4623)
14'-10"(4521)
15'-1"(4597)
HHPIT DEPTH
(mm)
5'-3"(1600)
5'-3"(1600)
5'-3"(1600)
5'-5"(1651)
5'-6"(1676)
IICLEAR
OVERHD (mm)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
SEISMICHHPIT DEPTH
(mm)
6'-7"(2007)
6'-5"(1956)
6'-5"(1956)
6'-5"(1956)
6'-6"(1981)
SEISMICIICLEAR
OVERHD (mm)
16'-11"(5156)
16'-7"(5055)
16'-10"(5131)
16'-4"(4978)
16'-7"(5055)
HHPIT DEPTH
(mm)
5'-7"(1702)
5'-5"(1651)
5'-5"(1651)
5'-5"(1651)
5'-6"(1676)
IICLEAR
OVERHD (mm)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
SEISMICHHPIT DEPTH
(mm)
6'-7"(2007)
6'-5"(1956)
6'-5"(1956)
6'-5"(1956)
8"-5"(2565)
SEISMICIICLEAR
OVERHD (mm)
16'-11"(5156)
16'-7"(5055)
16'-10"(5131)
16'-4"(4978)
16'-11"(5156)
HHPIT DEPTH
(mm)
5'-7"(1702)
5'-5"(1651)
5'-5"(1651)
5'-5"(1651)
7'-5"(2261)
II
2000 to 4000 integral or remote cabinet 4'-4" 1'-8" 4'-0" (907 to 1814) (1321) (508) (1219)
2000 to 4000 adjacent or remote room 5'-0" dimension (B) 3'-0" (907 to 1814) (1524) (914)
2000 to 5000 AIA integral or remote cabinet 4'-4" 1'-8" 4'-0" (907 to 2268) (1321) (508) (1219)
2000 to 5000 AIA adjacent or remote room 5'-0" dimension (B) 3'-0" (907 to 2268) (1524) (914)
2000 5'-4" (1626) 13'-1" (3988) – – – – 2500 – 3500 5'-5" (1651) 13'-7" (4140) 5'-5" (1651) 13'-11" (4242) 5'-5" (1651) 13'-11" (4242) 4000 5'-8" (1728) 13'-7" (4140) 5'-8" (1728) 13'-11" (4242) 5'-8" (1727) 13'-11" (4242) 4500 5'-8" (1728) 14'-0" (4267) 5'-11" (1803) 14'-3" (4343) – – 5000 – 5000 AIA 5'-11" (1803) 14'-5" (4394) 5'-11" (1803) 14'-10" (4521) – –
2000 (907) 5'-4" (1626) 13'-1" (3988) – – – – 2500 (1134) 5'-3" (1600) 13'-7" (4140) 5'-5" (1651) 13'-11" (4242) 5'-5" (1651) 13'-11" (4242) 3000 (1361) 5'-5" (1651) 13'-7" (4140) 5'-5" (1651) 14'-4" (4369) 5'-5" (1651) 14'-4" (4369) 3500 (1588) 5'-5" (1651) 13'-7" (4140) 5'-5" (1651) 14'-9" (4496) 5'-5" (1651) 14'-9" (4496) 4000 (1814) 5'-8" (1727) 13'-7" (4140) 5'-8" (1727) 14'-11" (4547) 7'-3" (2210) 15'-8" (4775) 4500 (2141) 5'-8" (1727) 14'-9" (4496) 5'-11" (1803) 15'-3" (4648) 7'-6" (2286) 16'-0" (4877) 5000 – 5000 AIA 5'-11" (1803) 15'-2" (4623) 5'-11" (1803) 15'-11" (4551) – – (2268)
CAPACITYlbs. (kg)
2000 (907)2500 (1134)3000 (1361)3500 (1588)4000 (1814)
PASS
ENG
ERPA
SSEN
GER
PASS
ENG
ERSE
RVIC
ESE
RVIC
E
Fro
nt
Op
enin
g
Clear Overhead and Pit Depth
Co
ntr
ol S
pac
eFr
on
t &
Rev
erse
Op
enin
gFr
on
t O
pen
ing
OPENINGTYPE
SSPSSP-COSSP-COSSP-CO
CO
HOISTWAYWIDTH (mm)
7'-4" (2235)8'-4" (2540)8'-4" (2540)8'-4" (2540)9'-4" (2845)
AA
CAPACITYlbs. (kg)
2000 (907)2500 (1134)3000 (1361)3500 (1588)4000 (1814)
4000 (1814)4500 (2041)5000 (2268)
5000 AIA (2268)
2500 (1134)3000 (1361)3500 (1588)4000 (1814)
4000 (1814)4500 (2041)5000 (2268)
5000 AIA (2268)
OPENINGTYPE
SSPSSP-COSSP-COSSP-CO
CO
2SP2SP2SP2SP
SSP-COSSP-COSSP-CO
CO
2SP2SP2SP2SP
INTERIORDEPTH (mm)
4'-31⁄4" (1302)4'-31⁄4" (1302)4'-91⁄4" (1454)5'-51⁄4" (1657)5'-51⁄4" (1657)
7'-6" (2286)8'-0 " (2438)8'-73⁄4" (2635)9'-0" (2743)
4'-33⁄4" (1314)4'-93⁄4" (1467)5'-53⁄4" (1670)5'-53⁄4" (1670)
7'-61⁄2" (2299)8'-01⁄2" (2451)8'-81⁄4" (2648)9'-0" (2743)
DDHOISTWAY
WIDTH (mm)
8'-4" (2540)9'-9" (2972)9'-9" (2972)9'-9" (2972)
10'-9" (3277)
8'-9" (2667)8'-9" (2667)8'-9" (2667)8'-9" (2667)
9'-9" (2972)9'-9" (2972)9'-9" (2972)
10'-9" (3277)
8'-9" (2667)8'-9" (2667)8'-9" (2667)8'-9" (2667)
HOISTWAYDEPTH (mm)
6'-7" (2007)7'-1" (2159)7'-4" (2235)7'-8" (2337)7'-8" (2337)
9'-8" (2946)10'-2" (3099)10'-5" (3175)
10'-103⁄4" (3321)
7'-1" (2159)7'-6" (2286)
7'-91⁄2" (2375)7'-91⁄2" (2375)
10'-1" (3073)10'-7" (3226)
11'-23⁄4" (3422)11'-63⁄4" (3524)
DOORWIDTH (mm)
3'-0" (914)3'-6" (1067)3'-6" (1067)3'-6" (1067)4'-0" (1219)
4'-0" (1219)4'-0" (1219)4'-6" (1372)*4'-6" (1372)*
3'-6" (1067)3'-6" (1067)3'-6" (1067)4'-0" (1219)
4'-0" (1219)4'-0" (1219)4'-6" (1372)*4'-6" (1372)*
EEINTERIOR
WIDTH (mm)
5'-81⁄2" (1740)6'-81⁄2" (2045)6'-81⁄2" (2045)6'-81⁄2" (2045)7'-81⁄2" (2350)
5'-81⁄2" (1740)5'-81⁄2" (1740)5'-81⁄2" (1740)5'-81⁄2" (1740)
6'-81⁄2" (2045)6'-81⁄2" (2045)6'-81⁄2" (2045)7'-81⁄2" (2350)
5'-81⁄2" (1740)5'-81⁄2" (1740)5'-81⁄2" (1740)5'-81⁄2" (1740)
CCHOISTWAY
DEPTH (mm)
6'-4" (1930)6'-10" (2083)7'-1" (2159)7'-5" (2261)7'-5" (2261)
9'-5" (2870)9'-11" (3023)10'-2" (3099)
10'-73⁄4" (3245)
7'-1" (2159)7'-6" (2286)
7'-91⁄2" (2375)7'-91⁄2" (2375)
10'-1" (3073)10'-7" (3226)
11'-23⁄4" (3422)11'-63⁄4" (3524)
BBHOISTWAY
WIDTH (mm)
8'-0" (2438)9'-5" (2870)9'-5" (2870)9'-5" (2870)10'-5" (3175)
8'-5" (2565)8'-5" (2565)8'-5" (2565)8'-5" (2565)
9'-5" (2870)9'-5" (2870)9'-5" (2870)10'-5" (3175)
8'-5" (2565)8'-5" (2565)8'-5" (2565)8'-5" (2565)
AA
HOISTWAYDEPTH (mm)
6'-8" (2032)6'-8" (2032)7'-2" (2184)
7'-10" (2388)7'-10" (2388)
BB
CAPACITYlbs. (kg)
2000(907)
2500(1134)
3000(1361)
3500(1588)
4000(1814)
INTERIORWIDTH (mm)
5'-81⁄2" (1740)6'-81⁄2" (2045)6'-81⁄2" (2045)6'-81⁄2" (2045)7'-81⁄2" (2350)
CCINTERIOR
DEPTH (mm)
4'-31⁄4" (1302)4'-31⁄4" (1302)4'-91⁄4" (1454)5'-51⁄4" (1657)5'-51⁄4" (1657)
DDDOOR
WIDTH (mm)
3'-0" (914)3'-6" (1067)3'-6" (1067)3'-6" (1067)4'-0" (1219)
EE
HH II
HOISTWAYWIDTH (mm)
7'-8" (2337)8'-8" (2642)8'-8" (2642)8'-8" (2642)9'-8" (2946)
AA SEISMIC
AA SEISMIC BB SEISMIC
200 FPM (1.00 m/s) 350 FPM (1.78 m/s) 500 FPM (2.54 m/s)
CLEAROVERHD (mm)
16'-11"(5156)
16'-11(5156)
16'-11(5156)
16'-11(5156)
16'-11(5156)
SEISMICHHPIT DEPTH
(mm)
5'-3"(1600)
5'-3"(1600)
5'-3"(1600)
5'-5"(1651)
5'-6"(1676)
SEISMICIICLEAR
OVERHD (mm)
15'-6"(4724)
15'-0"(4572)
15'-2"(4623)
14'-10"(4521)
15'-1"(4597)
HHPIT DEPTH
(mm)
5'-3"(1600)
5'-3"(1600)
5'-3"(1600)
5'-5"(1651)
5'-6"(1676)
IICLEAR
OVERHD (mm)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
SEISMICHHPIT DEPTH
(mm)
6'-7"(2007)
6'-5"(1956)
6'-5"(1956)
6'-5"(1956)
6'-6"(1981)
SEISMICIICLEAR
OVERHD (mm)
16'-11"(5156)
16'-7"(5055)
16'-10"(5131)
16'-4"(4978)
16'-7"(5055)
HHPIT DEPTH
(mm)
5'-7"(1702)
5'-5"(1651)
5'-5"(1651)
5'-5"(1651)
5'-6"(1676)
IICLEAR
OVERHD (mm)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
SEISMICHHPIT DEPTH
(mm)
6'-7"(2007)
6'-5"(1956)
6'-5"(1956)
6'-5"(1956)
8"-5"(2565)
SEISMICIICLEAR
OVERHD (mm)
16'-11"(5156)
16'-7"(5055)
16'-10"(5131)
16'-4"(4978)
16'-11"(5156)
HHPIT DEPTH
(mm)
5'-7"(1702)
5'-5"(1651)
5'-5"(1651)
5'-5"(1651)
7'-5"(2261)
II
KONE MonoSpace Planning Guide:Machine at Rear Configuration – Optimizes Space (Available in passenger shape with front opening option)
MAX TRAVEL(9) 300 ft. (91.4 m)
MAX LANDINGS 36
SPEED 200, 350, 500 fpm (1.00, 1.78, 2.54 m/s)
CAR HEIGHT 8, 9 or 10 ft. (2438, 2743 or 3048 mm)
ENTRANCE HEIGHT 7, 8 or 9 ft. (2134, 2438 or 2743 mm)
F
G
Notes(1) Smaller Pit and Overhead dimensions may
be available per specific applications. Contact your KONE Sales Professional for further information.
(2) Buffer service platforms are required when pit depth exceeds 8'-6" (2590 mm).
(3) Hoist beams (by KONE) are required for installation (by others). Dimension H reflects clear under hoist beam.
(4) If occupied space exists below the hoistway, consult your KONE Sales Professional.
(5) All dimensions are based on an 8'-0" (2438 mm) cab with a 7'-0" (2134 mm) door. Alternate car and door heights are available, but may affect dimension H .
(6) Add 8" (203 mm) in non-seismic and 12" (305 mm) in seismic zones to clear overhead dimension H for front-only passenger car if cab features glass-back wall.
(7) If an EBD (Emergency Battery Device) is required, please contact your KONE Sales Professional for further detail regarding dimensions J and L .
(8) Contact your local KONE Sales Representative regarding local code variations when utilizing the integral and remote closet options.
Visit www.kone.us for the latest job-specific details, BIM Models, CAD drawings, specifications, electrical data, reaction loads and building access requirements.
9KONE Architectural Planning Guide
KO
NE Eco
Space
KO
NE M
on
oSp
ace K
ON
E EcoSystem
MR
KO
NE Po
laris
Integral Controller Space (standard)
(6)
AC
D
K
B
LJ
E
(7)
Adjacent or Remote Control Room
(option 2)
B
L
J
(7)
Remote Control Closet (option 1)
K
LJ
(7)
(3)
(1) (2)
H F G
G
I
(4)
(5) (6)
TRAVEL
Plan Views
Section View
10 KONE Architectural Planning Guide
Notes(1) Smaller Pit and Overhead dimensions may be
available per specific applications. Contact your KONE Sales Professional for further information.
(2) Buffer service platforms are required when pit depth exceeds 8'-6" (2590 mm).
(3) A hoist beam (by KONE) is required for installation (by others). Dimension H reflects clear under hoist beam.
(4) If occupied space exists below the hoistway, consult your KONE Sales Professional.
(5) All dimensions are based on an 8'-0" (2438 mm) cab with a 7'-0" (2134 mm) door. Alternate car and door heights are available, but will affect dimension H .
(6) For 2,000 lb. (907 kg) capacity, maximum travel = 90' (27.4 m) and maximum openings = 10.
(7) If an EBD (Emergency Battery Device) is required, please contact your KONE Sales Professional for further detail regarding dimensions J and L .
(8) Contact your local KONE Sales Representative regarding local code variations when utilizing the integral and remote closet options.
Visit www.kone.us for the latest job-specific details, BIM Models, CAD drawings, specifications, electrical data, reaction loads and building access requirements.
MAX TRAVEL(6,7) 300 ft. (91.4 m)MAX LANDINGS 36SPEED 200, 350, 500 fpm (1.00, 1.78, 2.54 m/s)CAR HEIGHT 8, 9 or 10 ft. (2438, 2743 or 3048 mm)ENTRANCE HEIGHT 7, 8 or 9 ft. (2134, 2438 or 2743 mm)
F
G
2000 to 4000 integral or remote cabinet 4'-4" 1'-8" 4'-0" (907 to 1814) (1321) (508) (1219)
2000 to 4000 adjacent or remote room 5'-0" dimension (B) 3'-0" (907 to 1814) (1524) (914)
2000 to 5000 AIA integral or remote cabinet 4'-4" 1'-8" 4'-0" (907 to 2268) (1321) (508) (1219)
2000 to 5000 AIA adjacent or remote room 5'-0" dimension (B) 3'-0" (907 to 2268) (1524) (914)
2000 5'-4" (1626) 13'-1" (3988) – – – – 2500 – 3500 5'-5" (1651) 13'-7" (4140) 5'-5" (1651) 13'-11" (4242) 5'-5" (1651) 13'-11" (4242) 4000 5'-8" (1728) 13'-7" (4140) 5'-8" (1728) 13'-11" (4242) 5'-8" (1727) 13'-11" (4242) 4500 5'-8" (1728) 14'-0" (4267) 5'-11" (1803) 14'-3" (4343) – – 5000 – 5000 AIA 5'-11" (1803) 14'-5" (4394) 5'-11" (1803) 14'-10" (4521) – –
2000 (907) 5'-4" (1626) 13'-1" (3988) – – – – 2500 (1134) 5'-3" (1600) 13'-7" (4140) 5'-5" (1651) 13'-11" (4242) 5'-5" (1651) 13'-11" (4242) 3000 (1361) 5'-5" (1651) 13'-7" (4140) 5'-5" (1651) 14'-4" (4369) 5'-5" (1651) 14'-4" (4369) 3500 (1588) 5'-5" (1651) 13'-7" (4140) 5'-5" (1651) 14'-9" (4496) 5'-5" (1651) 14'-9" (4496) 4000 (1814) 5'-8" (1727) 13'-7" (4140) 5'-8" (1727) 14'-11" (4547) 7'-3" (2210) 15'-8" (4775) 4500 (2141) 5'-8" (1727) 14'-9" (4496) 5'-11" (1803) 15'-3" (4648) 7'-6" (2286) 16'-0" (4877) 5000 – 5000 AIA 5'-11" (1803) 15'-2" (4623) 5'-11" (1803) 15'-11" (4551) – – (2268)
CAPACITYlbs. (kg)
2000 (907)2500 (1134)3000 (1361)3500 (1588)4000 (1814)
PASS
ENG
ERPA
SSEN
GER
PASS
ENG
ERSE
RVIC
ESE
RVIC
E
Fro
nt
Op
enin
g
Clear Overhead and Pit Depth
Co
ntr
ol S
pac
eFr
on
t &
Rev
erse
Op
enin
gFr
on
t O
pen
ing
OPENINGTYPE
SSPSSP-COSSP-COSSP-CO
CO
HOISTWAYWIDTH (mm)
7'-4" (2235)8'-4" (2540)8'-4" (2540)8'-4" (2540)9'-4" (2845)
AA
CAPACITYlbs. (kg)
2000 (907)2500 (1134)3000 (1361)3500 (1588)4000 (1814)
4000 (1814)4500 (2041)5000 (2268)
5000 AIA (2268)
2500 (1134)3000 (1361)3500 (1588)4000 (1814)
4000 (1814)4500 (2041)5000 (2268)
5000 AIA (2268)
OPENINGTYPE
SSPSSP-COSSP-COSSP-CO
CO
2SP2SP2SP2SP
SSP-COSSP-COSSP-CO
CO
2SP2SP2SP2SP
INTERIORDEPTH (mm)
4'-31⁄4" (1302)4'-31⁄4" (1302)4'-91⁄4" (1454)5'-51⁄4" (1657)5'-51⁄4" (1657)
7'-6" (2286)8'-0 " (2438)8'-73⁄4" (2635)9'-0" (2743)
4'-33⁄4" (1314)4'-93⁄4" (1467)5'-53⁄4" (1670)5'-53⁄4" (1670)
7'-61⁄2" (2299)8'-01⁄2" (2451)8'-81⁄4" (2648)9'-0" (2743)
DDHOISTWAY
WIDTH (mm)
8'-4" (2540)9'-9" (2972)9'-9" (2972)9'-9" (2972)
10'-9" (3277)
8'-9" (2667)8'-9" (2667)8'-9" (2667)8'-9" (2667)
9'-9" (2972)9'-9" (2972)9'-9" (2972)
10'-9" (3277)
8'-9" (2667)8'-9" (2667)8'-9" (2667)8'-9" (2667)
HOISTWAYDEPTH (mm)
6'-7" (2007)7'-1" (2159)7'-4" (2235)7'-8" (2337)7'-8" (2337)
9'-8" (2946)10'-2" (3099)10'-5" (3175)
10'-103⁄4" (3321)
7'-1" (2159)7'-6" (2286)
7'-91⁄2" (2375)7'-91⁄2" (2375)
10'-1" (3073)10'-7" (3226)
11'-23⁄4" (3422)11'-63⁄4" (3524)
DOORWIDTH (mm)
3'-0" (914)3'-6" (1067)3'-6" (1067)3'-6" (1067)4'-0" (1219)
4'-0" (1219)4'-0" (1219)4'-6" (1372)*4'-6" (1372)*
3'-6" (1067)3'-6" (1067)3'-6" (1067)4'-0" (1219)
4'-0" (1219)4'-0" (1219)4'-6" (1372)*4'-6" (1372)*
EEINTERIOR
WIDTH (mm)
5'-81⁄2" (1740)6'-81⁄2" (2045)6'-81⁄2" (2045)6'-81⁄2" (2045)7'-81⁄2" (2350)
5'-81⁄2" (1740)5'-81⁄2" (1740)5'-81⁄2" (1740)5'-81⁄2" (1740)
6'-81⁄2" (2045)6'-81⁄2" (2045)6'-81⁄2" (2045)7'-81⁄2" (2350)
5'-81⁄2" (1740)5'-81⁄2" (1740)5'-81⁄2" (1740)5'-81⁄2" (1740)
CCHOISTWAY
DEPTH (mm)
6'-4" (1930)6'-10" (2083)7'-1" (2159)7'-5" (2261)7'-5" (2261)
9'-5" (2870)9'-11" (3023)10'-2" (3099)
10'-73⁄4" (3245)
7'-1" (2159)7'-6" (2286)
7'-91⁄2" (2375)7'-91⁄2" (2375)
10'-1" (3073)10'-7" (3226)
11'-23⁄4" (3422)11'-63⁄4" (3524)
BBHOISTWAY
WIDTH (mm)
8'-0" (2438)9'-5" (2870)9'-5" (2870)9'-5" (2870)10'-5" (3175)
8'-5" (2565)8'-5" (2565)8'-5" (2565)8'-5" (2565)
9'-5" (2870)9'-5" (2870)9'-5" (2870)10'-5" (3175)
8'-5" (2565)8'-5" (2565)8'-5" (2565)8'-5" (2565)
AA
HOISTWAYDEPTH (mm)
6'-8" (2032)6'-8" (2032)7'-2" (2184)
7'-10" (2388)7'-10" (2388)
BB
CAPACITYlbs. (kg)
2000(907)
2500(1134)
3000(1361)
3500(1588)
4000(1814)
INTERIORWIDTH (mm)
5'-81⁄2" (1740)6'-81⁄2" (2045)6'-81⁄2" (2045)6'-81⁄2" (2045)7'-81⁄2" (2350)
CCINTERIOR
DEPTH (mm)
4'-31⁄4" (1302)4'-31⁄4" (1302)4'-91⁄4" (1454)5'-51⁄4" (1657)5'-51⁄4" (1657)
DDDOOR
WIDTH (mm)
3'-0" (914)3'-6" (1067)3'-6" (1067)3'-6" (1067)4'-0" (1219)
EE
HH II
HOISTWAYWIDTH (mm)
7'-8" (2337)8'-8" (2642)8'-8" (2642)8'-8" (2642)9'-8" (2946)
AA SEISMIC
AA SEISMIC BB SEISMIC
200 FPM (1.00 m/s) 350 FPM (1.78 m/s) 500 FPM (2.54 m/s)
CLEAROVERHD (mm)
16'-11"(5156)
16'-11(5156)
16'-11(5156)
16'-11(5156)
16'-11(5156)
SEISMICHHPIT DEPTH
(mm)
5'-3"(1600)
5'-3"(1600)
5'-3"(1600)
5'-5"(1651)
5'-6"(1676)
SEISMICIICLEAR
OVERHD (mm)
15'-6"(4724)
15'-0"(4572)
15'-2"(4623)
14'-10"(4521)
15'-1"(4597)
HHPIT DEPTH
(mm)
5'-3"(1600)
5'-3"(1600)
5'-3"(1600)
5'-5"(1651)
5'-6"(1676)
IICLEAR
OVERHD (mm)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
SEISMICHHPIT DEPTH
(mm)
6'-7"(2007)
6'-5"(1956)
6'-5"(1956)
6'-5"(1956)
6'-6"(1981)
SEISMICIICLEAR
OVERHD (mm)
16'-11"(5156)
16'-7"(5055)
16'-10"(5131)
16'-4"(4978)
16'-7"(5055)
HHPIT DEPTH
(mm)
5'-7"(1702)
5'-5"(1651)
5'-5"(1651)
5'-5"(1651)
5'-6"(1676)
IICLEAR
OVERHD (mm)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
SEISMICHHPIT DEPTH
(mm)
6'-7"(2007)
6'-5"(1956)
6'-5"(1956)
6'-5"(1956)
8"-5"(2565)
SEISMICIICLEAR
OVERHD (mm)
16'-11"(5156)
16'-7"(5055)
16'-10"(5131)
16'-4"(4978)
16'-11"(5156)
HHPIT DEPTH
(mm)
5'-7"(1702)
5'-5"(1651)
5'-5"(1651)
5'-5"(1651)
7'-5"(2261)
II
2000 to 4000 integral or remote cabinet 4'-4" 1'-8" 4'-0" (907 to 1814) (1321) (508) (1219)
2000 to 4000 adjacent or remote room 5'-0" dimension (B) 3'-0" (907 to 1814) (1524) (914)
2000 to 5000 AIA integral or remote cabinet 4'-4" 1'-8" 4'-0" (907 to 2268) (1321) (508) (1219)
2000 to 5000 AIA adjacent or remote room 5'-0" dimension (B) 3'-0" (907 to 2268) (1524) (914)
2000 5'-4" (1626) 13'-1" (3988) – – – – 2500 – 3500 5'-5" (1651) 13'-7" (4140) 5'-5" (1651) 13'-11" (4242) 5'-5" (1651) 13'-11" (4242) 4000 5'-8" (1728) 13'-7" (4140) 5'-8" (1728) 13'-11" (4242) 5'-8" (1727) 13'-11" (4242) 4500 5'-8" (1728) 14'-0" (4267) 5'-11" (1803) 14'-3" (4343) – – 5000 – 5000 AIA 5'-11" (1803) 14'-5" (4394) 5'-11" (1803) 14'-10" (4521) – –
2000 (907) 5'-4" (1626) 13'-1" (3988) – – – – 2500 (1134) 5'-3" (1600) 13'-7" (4140) 5'-5" (1651) 13'-11" (4242) 5'-5" (1651) 13'-11" (4242) 3000 (1361) 5'-5" (1651) 13'-7" (4140) 5'-5" (1651) 14'-4" (4369) 5'-5" (1651) 14'-4" (4369) 3500 (1588) 5'-5" (1651) 13'-7" (4140) 5'-5" (1651) 14'-9" (4496) 5'-5" (1651) 14'-9" (4496) 4000 (1814) 5'-8" (1727) 13'-7" (4140) 5'-8" (1727) 14'-11" (4547) 7'-3" (2210) 15'-8" (4775) 4500 (2141) 5'-8" (1727) 14'-9" (4496) 5'-11" (1803) 15'-3" (4648) 7'-6" (2286) 16'-0" (4877) 5000 – 5000 AIA 5'-11" (1803) 15'-2" (4623) 5'-11" (1803) 15'-11" (4551) – – (2268)
CAPACITYlbs. (kg)
2000 (907)2500 (1134)3000 (1361)3500 (1588)4000 (1814)
PASS
ENG
ERPA
SSEN
GER
PASS
ENG
ERSE
RVIC
ESE
RVIC
E
Fro
nt
Op
enin
g
Clear Overhead and Pit Depth
Co
ntr
ol S
pac
eFr
on
t &
Rev
erse
Op
enin
gFr
on
t O
pen
ing
OPENINGTYPE
SSPSSP-COSSP-COSSP-CO
CO
HOISTWAYWIDTH (mm)
7'-4" (2235)8'-4" (2540)8'-4" (2540)8'-4" (2540)9'-4" (2845)
AA
CAPACITYlbs. (kg)
2000 (907)2500 (1134)3000 (1361)3500 (1588)4000 (1814)
4000 (1814)4500 (2041)5000 (2268)
5000 AIA (2268)
2500 (1134)3000 (1361)3500 (1588)4000 (1814)
4000 (1814)4500 (2041)5000 (2268)
5000 AIA (2268)
OPENINGTYPE
SSPSSP-COSSP-COSSP-CO
CO
2SP2SP2SP2SP
SSP-COSSP-COSSP-CO
CO
2SP2SP2SP2SP
INTERIORDEPTH (mm)
4'-31⁄4" (1302)4'-31⁄4" (1302)4'-91⁄4" (1454)5'-51⁄4" (1657)5'-51⁄4" (1657)
7'-6" (2286)8'-0 " (2438)8'-73⁄4" (2635)9'-0" (2743)
4'-33⁄4" (1314)4'-93⁄4" (1467)5'-53⁄4" (1670)5'-53⁄4" (1670)
7'-61⁄2" (2299)8'-01⁄2" (2451)8'-81⁄4" (2648)9'-0" (2743)
DDHOISTWAY
WIDTH (mm)
8'-4" (2540)9'-9" (2972)9'-9" (2972)9'-9" (2972)
10'-9" (3277)
8'-9" (2667)8'-9" (2667)8'-9" (2667)8'-9" (2667)
9'-9" (2972)9'-9" (2972)9'-9" (2972)
10'-9" (3277)
8'-9" (2667)8'-9" (2667)8'-9" (2667)8'-9" (2667)
HOISTWAYDEPTH (mm)
6'-7" (2007)7'-1" (2159)7'-4" (2235)7'-8" (2337)7'-8" (2337)
9'-8" (2946)10'-2" (3099)10'-5" (3175)
10'-103⁄4" (3321)
7'-1" (2159)7'-6" (2286)
7'-91⁄2" (2375)7'-91⁄2" (2375)
10'-1" (3073)10'-7" (3226)
11'-23⁄4" (3422)11'-63⁄4" (3524)
DOORWIDTH (mm)
3'-0" (914)3'-6" (1067)3'-6" (1067)3'-6" (1067)4'-0" (1219)
4'-0" (1219)4'-0" (1219)4'-6" (1372)*4'-6" (1372)*
3'-6" (1067)3'-6" (1067)3'-6" (1067)4'-0" (1219)
4'-0" (1219)4'-0" (1219)4'-6" (1372)*4'-6" (1372)*
EEINTERIOR
WIDTH (mm)
5'-81⁄2" (1740)6'-81⁄2" (2045)6'-81⁄2" (2045)6'-81⁄2" (2045)7'-81⁄2" (2350)
5'-81⁄2" (1740)5'-81⁄2" (1740)5'-81⁄2" (1740)5'-81⁄2" (1740)
6'-81⁄2" (2045)6'-81⁄2" (2045)6'-81⁄2" (2045)7'-81⁄2" (2350)
5'-81⁄2" (1740)5'-81⁄2" (1740)5'-81⁄2" (1740)5'-81⁄2" (1740)
CCHOISTWAY
DEPTH (mm)
6'-4" (1930)6'-10" (2083)7'-1" (2159)7'-5" (2261)7'-5" (2261)
9'-5" (2870)9'-11" (3023)10'-2" (3099)
10'-73⁄4" (3245)
7'-1" (2159)7'-6" (2286)
7'-91⁄2" (2375)7'-91⁄2" (2375)
10'-1" (3073)10'-7" (3226)
11'-23⁄4" (3422)11'-63⁄4" (3524)
BBHOISTWAY
WIDTH (mm)
8'-0" (2438)9'-5" (2870)9'-5" (2870)9'-5" (2870)10'-5" (3175)
8'-5" (2565)8'-5" (2565)8'-5" (2565)8'-5" (2565)
9'-5" (2870)9'-5" (2870)9'-5" (2870)10'-5" (3175)
8'-5" (2565)8'-5" (2565)8'-5" (2565)8'-5" (2565)
AA
HOISTWAYDEPTH (mm)
6'-8" (2032)6'-8" (2032)7'-2" (2184)
7'-10" (2388)7'-10" (2388)
BB
CAPACITYlbs. (kg)
2000(907)
2500(1134)
3000(1361)
3500(1588)
4000(1814)
INTERIORWIDTH (mm)
5'-81⁄2" (1740)6'-81⁄2" (2045)6'-81⁄2" (2045)6'-81⁄2" (2045)7'-81⁄2" (2350)
CCINTERIOR
DEPTH (mm)
4'-31⁄4" (1302)4'-31⁄4" (1302)4'-91⁄4" (1454)5'-51⁄4" (1657)5'-51⁄4" (1657)
DDDOOR
WIDTH (mm)
3'-0" (914)3'-6" (1067)3'-6" (1067)3'-6" (1067)4'-0" (1219)
EE
HH II
HOISTWAYWIDTH (mm)
7'-8" (2337)8'-8" (2642)8'-8" (2642)8'-8" (2642)9'-8" (2946)
AA SEISMIC
AA SEISMIC BB SEISMIC
200 FPM (1.00 m/s) 350 FPM (1.78 m/s) 500 FPM (2.54 m/s)
CLEAROVERHD (mm)
16'-11"(5156)
16'-11(5156)
16'-11(5156)
16'-11(5156)
16'-11(5156)
SEISMICHHPIT DEPTH
(mm)
5'-3"(1600)
5'-3"(1600)
5'-3"(1600)
5'-5"(1651)
5'-6"(1676)
SEISMICIICLEAR
OVERHD (mm)
15'-6"(4724)
15'-0"(4572)
15'-2"(4623)
14'-10"(4521)
15'-1"(4597)
HHPIT DEPTH
(mm)
5'-3"(1600)
5'-3"(1600)
5'-3"(1600)
5'-5"(1651)
5'-6"(1676)
IICLEAR
OVERHD (mm)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
SEISMICHHPIT DEPTH
(mm)
6'-7"(2007)
6'-5"(1956)
6'-5"(1956)
6'-5"(1956)
6'-6"(1981)
SEISMICIICLEAR
OVERHD (mm)
16'-11"(5156)
16'-7"(5055)
16'-10"(5131)
16'-4"(4978)
16'-7"(5055)
HHPIT DEPTH
(mm)
5'-7"(1702)
5'-5"(1651)
5'-5"(1651)
5'-5"(1651)
5'-6"(1676)
IICLEAR
OVERHD (mm)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
SEISMICHHPIT DEPTH
(mm)
6'-7"(2007)
6'-5"(1956)
6'-5"(1956)
6'-5"(1956)
8"-5"(2565)
SEISMICIICLEAR
OVERHD (mm)
16'-11"(5156)
16'-7"(5055)
16'-10"(5131)
16'-4"(4978)
16'-11"(5156)
HHPIT DEPTH
(mm)
5'-7"(1702)
5'-5"(1651)
5'-5"(1651)
5'-5"(1651)
7'-5"(2261)
II
KONE MonoSpace Planning Guide:Machine at Side Configuration – (Available in passenger and service shape with front and rear opening options)
2000 to 4000 integral or remote cabinet 4'-4" 1'-8" 4'-0" (907 to 1814) (1321) (508) (1219)
2000 to 4000 adjacent or remote room 5'-0" dimension (B) 3'-0" (907 to 1814) (1524) (914)
2000 to 5000 AIA integral or remote cabinet 4'-4" 1'-8" 4'-0" (907 to 2268) (1321) (508) (1219)
2000 to 5000 AIA adjacent or remote room 5'-0" dimension (B) 3'-0" (907 to 2268) (1524) (914)
2000 5'-4" (1626) 13'-1" (3988) – – – – 2500 – 3500 5'-5" (1651) 13'-7" (4140) 5'-5" (1651) 13'-11" (4242) 5'-5" (1651) 13'-11" (4242) 4000 5'-8" (1728) 13'-7" (4140) 5'-8" (1728) 13'-11" (4242) 5'-8" (1727) 13'-11" (4242) 4500 5'-8" (1728) 14'-0" (4267) 5'-11" (1803) 14'-3" (4343) – – 5000 – 5000 AIA 5'-11" (1803) 14'-5" (4394) 5'-11" (1803) 14'-10" (4521) – –
2000 (907) 5'-4" (1626) 13'-1" (3988) – – – – 2500 (1134) 5'-3" (1600) 13'-7" (4140) 5'-5" (1651) 13'-11" (4242) 5'-5" (1651) 13'-11" (4242) 3000 (1361) 5'-5" (1651) 13'-7" (4140) 5'-5" (1651) 14'-4" (4369) 5'-5" (1651) 14'-4" (4369) 3500 (1588) 5'-5" (1651) 13'-7" (4140) 5'-5" (1651) 14'-9" (4496) 5'-5" (1651) 14'-9" (4496) 4000 (1814) 5'-8" (1727) 13'-7" (4140) 5'-8" (1727) 14'-11" (4547) 7'-3" (2210) 15'-8" (4775) 4500 (2141) 5'-8" (1727) 14'-9" (4496) 5'-11" (1803) 15'-3" (4648) 7'-6" (2286) 16'-0" (4877) 5000 – 5000 AIA 5'-11" (1803) 15'-2" (4623) 5'-11" (1803) 15'-11" (4551) – – (2268)
CAPACITYlbs. (kg)
2000 (907)2500 (1134)3000 (1361)3500 (1588)4000 (1814)
PASS
ENG
ERPA
SSEN
GER
PASS
ENG
ERSE
RVIC
ESE
RVIC
E
Fro
nt
Op
enin
g
Clear Overhead and Pit Depth
Co
ntr
ol S
pac
eFr
on
t &
Rev
erse
Op
enin
gFr
on
t O
pen
ing
OPENINGTYPE
SSPSSP-COSSP-COSSP-CO
CO
HOISTWAYWIDTH (mm)
7'-4" (2235)8'-4" (2540)8'-4" (2540)8'-4" (2540)9'-4" (2845)
AA
CAPACITYlbs. (kg)
2000 (907)2500 (1134)3000 (1361)3500 (1588)4000 (1814)
4000 (1814)4500 (2041)5000 (2268)
5000 AIA (2268)
2500 (1134)3000 (1361)3500 (1588)4000 (1814)
4000 (1814)4500 (2041)5000 (2268)
5000 AIA (2268)
OPENINGTYPE
SSPSSP-COSSP-COSSP-CO
CO
2SP2SP2SP2SP
SSP-COSSP-COSSP-CO
CO
2SP2SP2SP2SP
INTERIORDEPTH (mm)
4'-31⁄4" (1302)4'-31⁄4" (1302)4'-91⁄4" (1454)5'-51⁄4" (1657)5'-51⁄4" (1657)
7'-6" (2286)8'-0 " (2438)8'-73⁄4" (2635)9'-0" (2743)
4'-33⁄4" (1314)4'-93⁄4" (1467)5'-53⁄4" (1670)5'-53⁄4" (1670)
7'-61⁄2" (2299)8'-01⁄2" (2451)8'-81⁄4" (2648)9'-0" (2743)
DDHOISTWAY
WIDTH (mm)
8'-4" (2540)9'-9" (2972)9'-9" (2972)9'-9" (2972)
10'-9" (3277)
8'-9" (2667)8'-9" (2667)8'-9" (2667)8'-9" (2667)
9'-9" (2972)9'-9" (2972)9'-9" (2972)
10'-9" (3277)
8'-9" (2667)8'-9" (2667)8'-9" (2667)8'-9" (2667)
HOISTWAYDEPTH (mm)
6'-7" (2007)7'-1" (2159)7'-4" (2235)7'-8" (2337)7'-8" (2337)
9'-8" (2946)10'-2" (3099)10'-5" (3175)
10'-103⁄4" (3321)
7'-1" (2159)7'-6" (2286)
7'-91⁄2" (2375)7'-91⁄2" (2375)
10'-1" (3073)10'-7" (3226)
11'-23⁄4" (3422)11'-63⁄4" (3524)
DOORWIDTH (mm)
3'-0" (914)3'-6" (1067)3'-6" (1067)3'-6" (1067)4'-0" (1219)
4'-0" (1219)4'-0" (1219)4'-6" (1372)*4'-6" (1372)*
3'-6" (1067)3'-6" (1067)3'-6" (1067)4'-0" (1219)
4'-0" (1219)4'-0" (1219)4'-6" (1372)*4'-6" (1372)*
EEINTERIOR
WIDTH (mm)
5'-81⁄2" (1740)6'-81⁄2" (2045)6'-81⁄2" (2045)6'-81⁄2" (2045)7'-81⁄2" (2350)
5'-81⁄2" (1740)5'-81⁄2" (1740)5'-81⁄2" (1740)5'-81⁄2" (1740)
6'-81⁄2" (2045)6'-81⁄2" (2045)6'-81⁄2" (2045)7'-81⁄2" (2350)
5'-81⁄2" (1740)5'-81⁄2" (1740)5'-81⁄2" (1740)5'-81⁄2" (1740)
CCHOISTWAY
DEPTH (mm)
6'-4" (1930)6'-10" (2083)7'-1" (2159)7'-5" (2261)7'-5" (2261)
9'-5" (2870)9'-11" (3023)10'-2" (3099)
10'-73⁄4" (3245)
7'-1" (2159)7'-6" (2286)
7'-91⁄2" (2375)7'-91⁄2" (2375)
10'-1" (3073)10'-7" (3226)
11'-23⁄4" (3422)11'-63⁄4" (3524)
BBHOISTWAY
WIDTH (mm)
8'-0" (2438)9'-5" (2870)9'-5" (2870)9'-5" (2870)10'-5" (3175)
8'-5" (2565)8'-5" (2565)8'-5" (2565)8'-5" (2565)
9'-5" (2870)9'-5" (2870)9'-5" (2870)10'-5" (3175)
8'-5" (2565)8'-5" (2565)8'-5" (2565)8'-5" (2565)
AA
HOISTWAYDEPTH (mm)
6'-8" (2032)6'-8" (2032)7'-2" (2184)
7'-10" (2388)7'-10" (2388)
BB
CAPACITYlbs. (kg)
2000(907)
2500(1134)
3000(1361)
3500(1588)
4000(1814)
INTERIORWIDTH (mm)
5'-81⁄2" (1740)6'-81⁄2" (2045)6'-81⁄2" (2045)6'-81⁄2" (2045)7'-81⁄2" (2350)
CCINTERIOR
DEPTH (mm)
4'-31⁄4" (1302)4'-31⁄4" (1302)4'-91⁄4" (1454)5'-51⁄4" (1657)5'-51⁄4" (1657)
DDDOOR
WIDTH (mm)
3'-0" (914)3'-6" (1067)3'-6" (1067)3'-6" (1067)4'-0" (1219)
EE
HH II
HOISTWAYWIDTH (mm)
7'-8" (2337)8'-8" (2642)8'-8" (2642)8'-8" (2642)9'-8" (2946)
AA SEISMIC
AA SEISMIC BB SEISMIC
200 FPM (1.00 m/s) 350 FPM (1.78 m/s) 500 FPM (2.54 m/s)
CLEAROVERHD (mm)
16'-11"(5156)
16'-11(5156)
16'-11(5156)
16'-11(5156)
16'-11(5156)
SEISMICHHPIT DEPTH
(mm)
5'-3"(1600)
5'-3"(1600)
5'-3"(1600)
5'-5"(1651)
5'-6"(1676)
SEISMICIICLEAR
OVERHD (mm)
15'-6"(4724)
15'-0"(4572)
15'-2"(4623)
14'-10"(4521)
15'-1"(4597)
HHPIT DEPTH
(mm)
5'-3"(1600)
5'-3"(1600)
5'-3"(1600)
5'-5"(1651)
5'-6"(1676)
IICLEAR
OVERHD (mm)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
SEISMICHHPIT DEPTH
(mm)
6'-7"(2007)
6'-5"(1956)
6'-5"(1956)
6'-5"(1956)
6'-6"(1981)
SEISMICIICLEAR
OVERHD (mm)
16'-11"(5156)
16'-7"(5055)
16'-10"(5131)
16'-4"(4978)
16'-7"(5055)
HHPIT DEPTH
(mm)
5'-7"(1702)
5'-5"(1651)
5'-5"(1651)
5'-5"(1651)
5'-6"(1676)
IICLEAR
OVERHD (mm)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
16"-11"(5156)
SEISMICHHPIT DEPTH
(mm)
6'-7"(2007)
6'-5"(1956)
6'-5"(1956)
6'-5"(1956)
8"-5"(2565)
SEISMICIICLEAR
OVERHD (mm)
16'-11"(5156)
16'-7"(5055)
16'-10"(5131)
16'-4"(4978)
16'-11"(5156)
HHPIT DEPTH
(mm)
5'-7"(1702)
5'-5"(1651)
5'-5"(1651)
5'-5"(1651)
7'-5"(2261)
II
* 4’-0” (1219 mm) door width also available
Plan Views
Section View
11KONE Architectural Planning Guide
KO
NE Eco
Space
KO
NE M
on
oSp
ace K
ON
E EcoSystem
MR
KO
NE Po
laris
Adjacent or Remote Control Room
(option 2)
B
L
J
(10)
Remote Control Closet (option 1)
K
LJ
(10)
Integral Controller Space (standard)
(8)
(8) (9)
AC
D
K
B
LJ
E
E
(10)
(3)
(1) (2)
H F G
G
I
(4)
(5)
(6) TRAVEL
KO
NE
Eco
Spac
e K
ON
E M
on
oSp
ace
KO
NE
Eco
Syst
em M
RK
ON
E Po
lari
s
12 KONE Architectural Planning Guide
KONE EcoSystem MR E
DB
ECA
(2)
(6)
I
TRAVEL
J
G
GF
(8)
(4)
(5)
SERV
ICE
PASS
ENG
ER
Fro
nt
& R
ever
se O
pen
ing
Fro
nt
Op
enin
g
SERV
ICE
PASS
ENG
ER
EcoSystem MR A B C D E
CAPACITY OPENING HOISTWAY HOISTWAY HOISTWAY INTERIOR INTERIOR DOOR lbs. (kg) TYPE WIDTH (mm) WIDTH (mm) DEPTH (mm) WIDTH (mm) DEPTH (mm) WIDTH (mm)
2000 SSP 7'-4" 7'-8" 6'-10" 5'-81⁄2" 4'-31⁄4" 3'-0" (907) (2235) (2337) (2083) (1740) (1302) (914) 2500 SSP-CO 8'-4" 8'-8" 6'-8" 6'-81⁄2" 4'-31⁄4" 3'-6" (1134) (2540) (2642) (2032) (2045) (1302) (1067) 3000 SSP-CO 8'-4" 8'-8" 7'-2" 6'-81⁄2" 4'-91⁄4" 3'-6" (1361) (2540) (2642) (2184) (2045) (1454) (1067) 3500 SSP-CO 8'-4" 8'-8" 7'-10" 6'-81⁄2" 5'-51⁄4" 3'-6" (1588) (2540) (2642) (2388) (2045) (1657) (1067) 4000 CO 9'-4" 9'-8" 7'-10" 7'-81⁄2" 5'-51⁄4" 4'-0" (1814) (2845) (2946) (2388) (2350) (1657) (1219)
4000 2SP 8'-1" 8'-4" 9'-2" 5'-81⁄2" 7'-6" 4'-0" (1814) (2464) (2540) (2794) (1740) (2286) (1219) 4500 2SP 8'-1" 8'-4" 9'-8" 5'-81⁄2" 8'-0" 4'-0" (2041) (2464) (2540) (2946) (1740) (2438) (1219) 5000 2SP 8'-1" 8'-4" 10'-2" 5'-81⁄2" 8'-73⁄4" 4'-6"* (2268) (2464) (2540) (3099) (1740) (2635) (1372) 5000 AIA 2SP 8'-8" 8'-11" 10'-73⁄4" 5'-81⁄2" 9'-0" 4'-6"* (2268) (2642) (2718) (3245) (1740) (2743) (1372)
2000 SSP 8'-4" 8'-8" 6'-31⁄4" 5'-81⁄2" 4'-33⁄4" 3'-0" (907) (2540) (2642) (1911) (1740) (1314) (914) 2500 SSP-CO 9'-4" 9'-8" 6'-31⁄4" 6'-81⁄2" 4'-33⁄4" 3'-6" (1134) (2845) (2946) (1911) (2045) (1314) (1067) 3000 SSP-CO 9'-4" 9'-8" 6'-91⁄4" 6'-81⁄2" 4'-93⁄4" 3'-6" (1361) (2845) (2946) (2064) (2045) (1467) (1067) 3500 SSP-CO 9'-4" 9'-8" 7'-51⁄4" 6'-81⁄2" 5'-53⁄4" 3'-6" (1588) (2845) (2946) (2267) (2045) (1670) (1067) 4000 CO 10'-4" 10'-8" 7'-51⁄4" 7'-81⁄2" 5'-53⁄4" 4'-0" (1814) (3150) (3251) (2267) (2350) (1670) (1219)
4000 2SP 8'-1" 8'-4" 10'-1" 5'-81⁄2" 7'-61⁄2" 4'-0" (1814) (2464) (2540) (3073) (1740) (2299) (1219) 4500 2SP 8'-1" 8'-4" 10'-7" 5'-81⁄2" 8'-01⁄2" 4'-0" (2041) (2464) (2540) (3226) (1740) (2451) (1219) 5000 2SP 8'-1" 8'-4" 11'-23⁄4" 5'-81⁄2" 8'-81⁄4" 4'-6"* (2268) (2464) (2540) (3423) (1740) (2648) (1372) 5000 AIA 2SP 8'-8" 9'-0" 11'-63⁄4" 5'-81⁄2" 9'-0" 4'-6"* (2268) (2642) (2743) (3524) (1740) (2743) (1372)
Notes(1) For speeds above 700 fpm (3.56 m/s) or travel
above 590' (180 m) contact your KONE Sales
Professional for design and planning assistance.
(2) For 700 fpm (3.56 m/s) front opening passenger
configurations add 2" (51 mm) to the hoistway
depth B .
(3) Information is based upon chain compensation.
For rope compensation applications, please
consult your KONE Sales Professional.
(4) All dimensions are based on an 8'-0" (2438 mm)
cab with a 7'-0" (2134 mm) door. Alternate car
and door heights are available, but will affect
dimension I .
(5) If occupied space exists below the hoistway,
consult your KONE Sales Professional.
(6) Information is based upon structural machine room
floor slabs. For machine beam applications, please
consult your KONE Sales Professional.
(7) Machine room height of 8'-0" (2438 mm) is
measured from the machine room floor surface
to underside of the lowest obstruction above
the machine H . Consult your KONE Sales
Professional for details.
(8) For service applications the machine room is
not centered on the hoistway and requires
an additional 7" (178 mm) of width. The
additional 7" (178 mm) should be added to
the counterweight side. Consult your KONE
Sales Professional for details.
Visit www.kone.us for the latest job-specific details, BIM Models, CAD drawings, specifications, electrical data, reaction loads and building access requirements.
MAX TRAVEL 590 ft. (180 m)
MAX LANDINGS 63
SPEED 200, 350, 400, 500, 700 fpm (1.00, 1.78, 2.00, 2.54, 3.56 m/s)
CAR HEIGHT 8, 9 or 10 ft. (2438, 2743 or 3048 mm)
ENTRANCE HEIGHT 7, 8 or 9 ft. (2134, 2438 or 2743 mm)
CLEAR OVERHEAD and PIT DEPTH
F
G
JI
H
* 4’-0” (1219 mm) door width also available
CAPACITY PIT CLEAR PIT CLEAR PIT CLEAR PIT CLEAR PIT CLEAR lbs. (kg) DEPTH OVRHD DEPTH OVRHD DEPTH OVRHD DEPTH OVRHD DEPTH OVRHD (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)
2000 – – – – – – – – 10'-6" 21'-0" (907) – – – – – – – – (3200 mm) (6401)
2500-3500 5'-3" 14'-1" 5'-6" 14'-7" 6'-0" 14'-11" 6'-10" 15'-8" 10'-6" 21'-0" (1134-1588) (1600) (4292) (1676) (4445) (1829) (4547) (2083) (4775) (3200) (6401)
4000 5-'3" 14'-1" 5'-6" 14'-7" 6'-0" 14'-11" 6'-10" 15'-8" – – (1814) (1600) (4292) (1676) (4445) (1829) (4547) (2083) (4775) – –
4500 5-'3" 14'-7" 5'-6" 15'-1" 6'-0" 15'-5" 6'-10" 16'-2" – – (2041) (1600) (4445) (1676) (4597) (1829) (4953) (2083) (4928) – –
5000 5-'3" 14'-7" 5'-6" 15'-1" 6'-0" 15'-5" 6'-10" 16'-2" – – (2268) (1600) (4445) (1676) (4597) (1829) (4953) (2083) (4928) – –
5000 AIA 5'-6" 14'-9" 5'-8" 15'-1" 7'-2" 16'-2" 7'-2" 16'-2" – – (2268) (1676) (4496) (1727) (4597) (2184) (4928) (2184) (4928) – –
700 FPM (1,2,3)200 FPM1.00 m/s
350 FPM1.78 m/s
400 FPM2.03 m/s
500 FPM2.54 m/s 3.56 m/s (1,2,3)
Clear Overhead and Pit DepthI J
A SEISMIC
13KONE Architectural Planning Guide
KO
NE Eco
Space
KO
NE M
on
oSp
ace K
ON
E EcoSystem
MR
KO
NE Po
laris
The KONE Polaris destination control system can dramatically improve the efficiency of your busy elevators! KONE Polaris offers:
n smart and easy-to-use elevators n uncrowded elevator cars
n better organized lobbies n fewer unnecessary stops
n shorter time to destination n less time spent in the elevator
n orderly boarding
Just select your destination and let KONE Polaris give you a perfect elevator experience.
Traditional elevator control systems work with very limited information as they register only the desired travel direction. The KONE Polaris Destination Control System (DCS) utilizes additional information like the desired destination floors and the number of waiting passengers.
With three times more information, KONE Polaris significantly improves system performance. It leads to increased handling capacity, shorter waiting times, fewer intermediate stops and an enhanced passenger experience.
The improvements are most concrete during intense traffic periods and rush hours when traditional control systems struggle to cope with the influx of increased demand.
KONE Polaris – an effortless elevator experience
Efficiency, comfort and securityThe KONE Polaris is an advanced dispatching system which is built on top of KONE’s industry leading group control technology. It features many unbeatable software features and algorithms such as:
n Artificial intelligence n Genetic algorithm
n Traffic forecasting n Multi objective optimization
n Fuzzy logic
Select your destination Select your destination floor at the Destination Operating Panel (DOP). The display will tell you which elevator has been assigned to you, and where it is located.
Move to your elevatorApproach the designated elevator. All elevators are clearly marked with identifiers above their doors.
Travel to your destination quickly and comfortablyOnce in the car, the next-stops indicator displays the destination stops the car will make. The position indicator informs you when you have arrived at your destination floor.
Arrive at your destination in three simple steps
Step 1 Step 2 Step 3
14
Item Component Transition radii
Truss
Side cladding
Step chain
Tracks
Return station
Access cover plate
Newel
Item Component Handrail
Skirting
Steps/pallets
Decking
Balustrade
Horizontal steps/pallets
Drive station
Controller
Front plate
Handrail drive
An introduction to escalators and autowalks
An escalator is a moving staircase for transporting people between floors of a building. It is generally agreed that an escalator is the most efficient means to move large numbers of people between floors.
Definitions and components
A horizontal autowalk is a conveyor belt that transports people horizontally. Autowalks are generally provided in areas where people need to walk long distances with luggage, baggage carts or shopping carts. An autowalk is generally flat, but can be slightly inclined.
KONE Architectural Planning Guide
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
16
14
15
12
133
1110
1
2
4
5
6
9
7
8
17
18
16
14
12
15
2 3
10
1
5
4
9
17
7
8
18
15KONE Architectural Planning Guide
Escalators + Autowalks
For the latest product information and interactive design tools, visit www.kone.us
n Quiet, smooth operation
n Small installation dimensions
n Eco-efficient and economical
n High levels of reliability
n Design options to match the image of your building
Application Heavy traffic, public transportation, metro
Type Escalator
Nominal Step Width 32", 40" (800, 1000 mm)
Balustrade Glass or solid
Speed 100 fpm (.50 m/s)
The versatile KONE TransitMaster 140 escalator is ideal for new installations and is specifically designed to meet the demanding needs of public transportation all the way up to the demanding requirements of mass transit airport and railway systems. Our heavy-duty escalators are designed to enable the seamless flow of large numbers of passengers.
Planning details are available in our full Escalator & Autowalk Planning Guide. See www.kone.us/escalators or contact your local KONE Sales Representative for more details.
Application Heavy traffic, airports, public transportation, metro
Type Autowalk
Length Per requirements
Nominal Pallet Width 32", 40", 48", 56" (800, 1000, 1200, 1400 mm)
Balustrade Glass or solid
Speed 100 or 130 fpm (.50 or .66 m/s)
The KONE Autowalk achieves the perfect balance between form and function. An attractive welcome area invites passengers to take an uncommonly smooth and quiet ride, while offering options to meet your architectural vision.
Application Retail, airports, stadiums, hotels, leisure venues
Type Complete escalator modernization
Nominal Step Width 24", 32", 40" (600, 800, 1000 mm)
Balustrade Glass or solid
Speed 100 fpm (.50 m/s)
The KONE EcoMod escalator modernization solution offers an innovative and systematic approach to replacing the entire workings of your escalators and delivering brand new KONE ECO3000® technology without expensive, disruptive truss removal.
KO
NE
Trav
elM
aste
r 11
0
Application Supermarkets, department stores, shopping centers
Type Escalator
Rise Maximum 31'-2" (9.5 m)
Nominal Step Width 24", 32", 40" (600, 800, 1000 mm)
Balustrade Glass or solid
Speed 100 fpm (.50 m/s)
The KONE TravelMaster 110 is a commercial escalator targeted primarily towards the retail segment – supermarkets, department stores and shopping centers. It is designed, from both a technical and visual point of view, to fulfill customer requirements in various target segments.
KO
NE
Tran
sitM
aste
r 14
0K
ON
E A
uto
wal
k K
ON
E Ec
oM
od
16 KONE Architectural Planning Guide
The KONE TravelMaster 110 is a commercial escalator primarily targeted towards the retail segment – supermarkets, department stores and shopping centers.
KONE TravelMaster 110 Notes(1) Details represent standard KONE escalator configurations.
Please consult your Sales Professional to review all possible deviations.
(2) Please visit www.kone.us for the latest job-specific details, electrical data, reaction loads, architectural toolbox and building access requirements.
Inclination Level Radii Maximum Nominal Balustrade Balustrade Speed Electrification Chain Type Handrail Environment Steps Vertical Rise Step Width Height
30 2 or 3 3'-33⁄8" or 31'-2" 24", 32" Glass, Solid 3'-33⁄8" 100 fpm ANSI Inside C-type Indoor degrees Level 4'-11" (9.5 m) and 40" Vertical (1000 mm) (0.5 m/s) Chain Semi- Steps (1.0 or (600, 800, Roller outdoor 1.5 m) 1000 mm) or Outdoor Upper Radius
KONE TM110 – Basic Data
KO
NE
Trav
elM
aste
r 11
0K
ON
E Tr
ansi
tMas
ter
140
KO
NE
Aut
ow
alk
KO
NE
Eco
Mo
d
KONE TransitMaster 140
17KONE Architectural Planning Guide
KONE TM140 escalators are available in two step widths, glass or solid balustrades and many other available options and finishes. The robust design, coupled with excellence in manufacturing and service, keep KONE at the top of the list of preferred suppliers of escalators for airports and lightly used railway or metro stations, public access, office or retail applications.
For detailed options and dimensional design data, please contact a KONE representative.
Notes(1) Details represent standard
KONE escalator configurations. Please consult your Sales Professional to review all possible deviations.
(2) Please visit www.kone.us for the latest job-specific details, electrical data, reaction loads, architectural toolbox and building access requirements.
Inclination 30 degrees
Level Steps 2–4 Level Steps
Radii 4'-11" or 8'-10" (1.5 or 2.7 m) Upper Radius
Maximum 60'-0" (18 m)Vertical Rise
Nominal 32" and 40" Step Width (800 and 1000 mm)
Balustrade Glass or Solid Inclined
Balustrade Height 3'-33⁄8" (1000 mm)
Speed 100 fpm (0.5 m/s)
Electrification ANSI
Chain Type Outside Chain Roller
Handrail V-type
Environment Indoor, Semi-outdoor or Outdoor
KONE TM140 – Basic Data
Width of truss
Width of escalator
Handrair outer edge distance
Safety fence
Pit width
66 [1678]
57 [1440]
40 [1000]
65 [1640]
70 [1780]
Detail 2
Detail 1
KO
NE TravelM
aster 110K
ON
E TransitM
aster 140K
ON
E Auto
walk
K
ON
E EcoM
od
18 KONE Architectural Planning Guide
KONE Autowalk StanchionKONE Autowalks have been installed in all types of applications. Exposition centers, stadiums, auditoriums and airports are only a few of the many applications where autowalks can move high numbers of people smoothly and efficiently. High-profile projects include: The Denver International Airport, Miami International Airport, Atlanta International Airport and Dallas-Fort Worth International Airport.
32" (800) 4'-111⁄8" (1052) 5'-11⁄8" (1553)
40" (1000) 5'-615⁄16" (1700) 5'-815⁄16" (1751)
48" (1200) 6'-23⁄4" (1899) 6'-43⁄4" (1950)
56" (1400) 6'-101⁄2" (2096) 7'-01⁄2" (2146)
KONE Autowalk – Stanchion StyleBasic DataNOMINAL PALLET WIDTH (A) (mm)
ROUGH OPENING (C) (mm)
FINISHED WIDTH (B) (mm)
Inclination 0 deg – 3 deg at ends for no wellway applications
Nominal 32", 40", 48" and 56" (800, Pallet Width 1000, 1200 and 1400 mm)
Balustrade Glass or Solid Vertical Panels
Balustrade 2'-103⁄16" (868 mm)Height
Speed 100 fpm (0.5 m/s) or 130 fpm (0.65 m/s)
Electrification ANSI
Chain Type Rollers outside chain links
Handrail V-type
Environment Indoor, Semi-outdoor or Outdoor
KONE Autowalk – Stanchion Basic Data
Notes(1) Details represent standard KONE autowalk
configurations. Please consult your Sales Professional to review all possible deviations.
(2) Please visit www.kone.us for the latest job-specific details, electrical data, reaction loads, architectural toolbox and building access requirements.
KO
NE
Trav
elM
aste
r 11
0K
ON
E Tr
ansi
tMas
ter
140
KO
NE
Aut
ow
alk
KO
NE
Eco
Mo
d
19KONE Architectural Planning Guide
KONE EcoModNew escalators the quick and easy wayKONE is the only company that offers a complete escalator modernization solution without the expense and disruption of removing the existing truss. KONE EcoMod delivers brand new escalator technology without the need to demolish floors, roofs and building façades, and there’s always an escalator available for passengers. EcoMod is designed to be compatible with both KONE escalators and equipment from other manufacturers. During modernization we can maintain continuous people flow through the ability to keep one escalator running while we work on the other.
New technology = better escalatorsn Improved equipment dependability
and performance
n Enhanced safety and reliability
n Energy-efficient technology for reduced operating costs
n Improved user experience with smoother rides
n Increased building value
For additional information please contact your KONE Sales Representative.
Quick and Easy InstallationA KONE EcoMod complete escalator modernization begins with the removal of all existing mechanical and electrical components. The existing truss is then modified to accept KONE EcoMod modules, allowing quick installation of the latest technology without major disruption.
upper module1
incline modules2
lower module3
EcoMod Installation Advantagesn Quicker, cleaner and less costly than a
new installation
n Modifying the existing truss means no major structural modifications
n Reuse of existing cladding and decking for significant cost-savings
n One or more escalators always available to passengers
n Increased building value and simplified budgeting process
Traditional Installation Disadvantagesn Lengthy process with extensive
construction
n Substantial general contractor costs for work by others
n Additional time for removal and prep of structural and related elements
n Complete escalator shutdown during construction
n Major disruption to people flow
It’s wise to modernize
KO
NE TravelM
aster 110K
ON
E TransitM
aster 140K
ON
E Auto
walk
K
ON
E EcoM
od
U.S. Operations CenterOne KONE CourtMoline, Illinois 612651-800-956-KONE (5663)
Canadian Operations Centre6696 Financial Drive, Unit 2Mississauga, Ontario L5N 7J61-905-858-8383
KONE Mexico, S.A. de C.V.Av. Coyoacán 1622 Ed. 1 PBCol. Del Valle SurMéxico City D.F. CP 03100+52.55.1946.0100
For the latest product information and interactive design tools, visit www.kone.us
U.S. Offices
Alabama Birmingham 205-944-1032 Mobile 251-661-7522
Arizona Phoenix 623-434-3599 Tucson 520-624-3125
Arkansas Little Rock 501-758-1889
California Cypress 714-890-7080 Sacramento 916-372-1458 San Diego 858-578-5100 San Francisco 510-351-5141 Santa Barbara 805-349-1013
Colorado Denver 303-792-3423
Connecticut Hartford 860-257-9277
Delaware 856-251-1555
District of Columbia Washington, DC 301-459-8660
Florida Jacksonville 904-292-0225 Miami 954-437-4300 Naples 239-598-9310 Orlando 407-812-8033 Tampa 813-635-0330
Georgia Atlanta 770-427-3373
Hawaii Honolulu 808-836-2231
Idaho 801-977-1144
Illinois Chicago 630-629-3100 Peoria 309-697-9011 Quad Cities 309-797-3232 Rockford 815-874-1502 Springfield 217-544-5461
Indiana Fort Wayne 260-484-9586 Indianapolis 317-788-0061
Alberta Calgary 403-275-5650 Edmonton 780-452-9227
British Columbia Vancouver 604-777-5663 Victoria 250-384-0613 Kelowna 778-436-8150
Iowa Des Moines 515-243-0109 Quad Cities 309-797-3232
Kansas Wichita 316-942-1201
Kentucky Louisville 502-491-0565
Louisiana Baton Rouge 225-291-5270 New Orleans 504-736-0776
Maine 781-828-6355
Maryland Baltimore 410-766-2100
Massachusetts Boston 781-828-6355
Michigan Detroit 734-513-6944 Grand Rapids 616-534-3300
Minnesota Minneapolis 651-452-8062
Mississippi Jackson 601-939-7597
Missouri Kansas City 816-531-2140 St. Louis 314-521-8800 Springfield 417-862-1174
Montana Helena 406-449-1399
Nebraska Omaha 402-592-7381
Nevada Las Vegas 702-269-0919
New Hampshire 781-828-6355
New Jersey Warren 908-626-0220
New Mexico Albuquerque 505-888-0626
New York Albany 518-464-0002 New York City 718-361-7200
North Carolina Charlotte 704-597-0430
Manitoba Winnipeg 204-895-2942
Nova Scotia Bedford 902-450-1102
Ontario Hamilton 905-648-3188 Kingston 613-531-6262 Ottawa 613-225-8222 Toronto 905-948-2230
North Dakota 651-452-8062
Ohio Cincinnati 513-755-6195 Cleveland 440-546-1100 Columbus 614-866-1751
Oklahoma Oklahoma City 405-682-5651 Tulsa 918-258-0582
Oregon Portland 503-652-1011
Pennsylvania Harrisburg 717-653-7177 Philadelphia 856-488-8830 Pittsburgh 412-279-1561
Rhode Island 781-828-6355
South Carolina 704-507-0430
South Dakota Sioux Falls 605-336-1578
Tennessee Knoxville 865-938-3444 Memphis 901-758-8320 Nashville 615-360-7013
Texas Austin 512-443-0967 Dallas 469-549-0581 Houston 281-442-6619 San Antonio 210-491-0485
Utah Salt Lake City 801-977-1144
Vermont 781-828-6355
Virginia Richmond 804-328-1032
Washington Seattle 425-861-9696
West Virginia Charleston 614-866-1751 Morgantown 412-279-1561
Wisconsin Milwaukee 262-373-0460
Wyoming 303-792-3423
Quebec Montreal 514-284-5663 Quebec City 418-877-1494 Sherbrooke 819-821-2182
Canada Offices
KONE Inc. reserves the right to alter design and specifications without prior notice.
KONE is a registered trademark of KONE Inc. Dedicated to People Flow and XXXXXXXXXX are trademarks of KONE Inc.
“USGBC” and related logo is a trademark owned by the U.S. Green Builging Council and is used by permission.
©2011 KONE Inc.SFXXXX Rev XXXXPrinted in U.S.A.
This document is printed using soy-based inks.
KONE Inc. reserves the right to alter design and specifications without prior notice.
KONE, ECO3000, EcoDisc, EcoMod and MonoSpace are registered trademarks of KONE Inc.
Care, Dedicated to People Flow, eOptimum, Eco-efficient, EcoSpace, EcoSpace EB, EcoSystem MR, KRMS, Polaris, TransitMaster and TravelMaster are trademarks of KONE Inc.
“USGBC” and related logo is a trademark owned by the U.S. Green Building Council and is used by permission.
©2013 KONE Inc.SF2861 Rev 1113Printed in U.S.A.